Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Electrical Works
Eprocure
Opening Date5 Dec 2020
Closing Date1 Jan 2021
Tender Amount₹ 29,13,333 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 76,480Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_MES_401096_1Bid Award Id
ViewTender No
8412/E8 OF 2020-2021Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
All as per Srl item No 2 above but point wiring for 5 pin socket outlet, 5 Amps on independent board.
35
-
-
All as per Srl item No 2 above but point wiring for one five pin socket outlet, 15 Amps & 5 Amp on independent board using 2.5 sqmm two run and one run 2.5 sqmm (nominal area) stranded copper conductor cable.
12
-
-
M&L for point wiring in non metallic PVC casing caping of suitable size but not less than 20mm including all fittings such as elbow, bends, junction boxes, saddles, etc. on surface with and including ISI marked two runs of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 sqmm nominal cross sectional area, 1100 volts grade and including one run of 1.5 sqmm (green colour) ISI marked PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire to be terminated in and incl PVC rectangular block of suitable size for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover for one light point or one fan point controlled by one switch including making good the disturbed wall and painting the same with matching to existing wall all as specified and directed by Engineer in charge.
75
-
-
All as per Srl item No 6 above but One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables1.5 sq.mm. Size.
5
-
-
All as per Srl item No 6 above but point wiring for 5 pin socket outlet, 5 Amps on same board with other switches.
22
-
-
All as per Srl item No 6 above but point wiring for 5 pin socket outlet, 5 Amps on independent board.
33
-
-
All as per Srl item No 6 above but point wiring for one five pin socket outlet, 15 Amps & 5 Amp on independent board using 2.5 sqmm two run and one run 2.5 sqmm (nominal area) stranded copper conductor cable.
10
-
-
Material and labour for point wiring for one light point or one fan point controlled by one switch in and including stove enamelled steel conduit with and including all steel enamelled fittings such as elbow bends, junction boxes, supporting clamps for proper hanging arregements made out from 25x3mm flat iron including nuts, bolts and bending to shape etc. of appropriate size but not less than 20mm on surface with two run of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 Sqmm nominal cross sectional area 1100 volts grade and including one run of 1.5 sqmm (green colour) PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire incl. suitable size sunken type Galvanised pressed sheet steel 1.6 mm thick terminal box of suitable size for mounting switches, sockets etc. and wiring to be terminated in pressed steel sunken boxes with and including all accessories and making good the disturbed wall and painting the same with matching colour of the existing wall, all as specified and directed.
170
-
-
All as per Srl item No 11 above but point wiring for 5 pin socket outlet, 5 Amps on same board with other switches.
20
-
-
All as per Srl item No 11 above but point wiring for 5 pin socket outlet, 5 Amps on independent board.
20
-
-
All a s per Srl item No 11 above but point wiring for one five pin socket outlet, 15 Amps & 5 Amp (independent) with using 2.5 sqmm two run and one run 1.5 sqmm (nominal area) stranded copper conductor.
35
-
-
Supplying & fixing switch flush type, 5 Amps, single pole, one way , 230 volts AC circuit complete all as specified & directed.
485
-
-
Supplying & fixing switch flush type, 5 Amps, Bell push , flush type , 230 volts AC circuit complete all as specified & directed.
5
-
-
Supplying & fixing Socket outlet 3 pin, 5A, flush type, multipurpose, 230 volts AC circuit complete all as specified & directed.
155
-
-
Supplying & fixing switch flush type, 15 Amps, single pole, one way , 230 volts AC circuit complete all as specified & directed.
57
-
-
Supplying & fixing Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type , flush type, 230 volts AC circuit complete all as specified & directed.
57
-
-
Supplying & fixing Ding Dong call bell AC 230 Volts single pole to be fixed on surface complete all as specified & directed.
5
-
-
Supplying & fixing ceiling rose PVC/polycarbonate, isolated body, three terminals, complete all as specified & directed.
330
-
-
Supply and fixing Lamp Holder white PVC/Polycabonate type with back plate suitable for batten fitting with and including LED retrofit white lamp 9 watt prewired 230 volts 50Hz Ac supply complete all as specified & directed.
10
-
-
Supply and fixing Stepped type electronic fan regulator flush type suitable for ceiling fans, prewired 230 volts AC 50Hz supply 100Watt complete all as specified & directed.
30
-
-
Supply, fixing, connecting and testing in replacement Industrial Earth Plug & socket with sheet metal enclosure electric driven single phase including MCB 'C' series SP 20 Amps and supplied with neutral links complete all as specified and directed.
50
-
-
S&F in replacement of PVC insulated, FR PVC round sheathed three core flexible copper conductor cable of size 1.0 sqmm including connecting the same to the fan/equipment and to the existing ceiling rose all as specified and approved by Engr-in-Charge.
100
-
-
Dismantling and Taking out old unserviceable copper/aluminium sub main wiring/Unarmoured cable (used as Sub main wiring) from any height of any Size and Core with all connecting accessories incld. conduit or casing caping and incld. making good to the disturbed wall and painting the same with matching paint as of existing wall all as specified and directed by Engineer in charge.
850
-
-
Material and labour for Sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, ISI marked, FRLSH type, 1.5 Sqmm, 1100 volts grade, drawn through and including New PVC casing and caping including connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, ISI marked, FRLSH type, 1.5 sqmm, 1100 Volts grade, ISI marked, as earth contuinity wire all as specified and directed by Engineer in charge. (Note:- (i) Two runs of cables & continuous earth wire in new PVC casing and caping / PVC non metallic conduit will be measured as one length of sub main wiring).
180
-
-
Material and labour for Sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, ISI marked, FRLSH type, 2.5 Sqmm, 1100 volts grade, drawn through and including New PVC casing and caping including connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, ISI marked, FRLSH type, 2.5 sqmm, 1100 Volts grade, ISI marked, as earth contuinity wire all as specified and directed by Engineer in charge. (Note:- (i) Two runs of cables & continuous earth wire in new PVC casing and caping / PVC non metallic conduit will be measured as one length of sub main wiring).
150
-
-
Material & Labour for Sub main wiring at any height with 2 single core PVC insulated, multi stranded copper conductor cable (FRLSH), unsheathed, 2.5 sqmm, 1100 volt grade drawn through and including New suitable size steel conduit and including one single core PVC insulated multi stranded unsheathed copper conductor cable, 2.5 sqmm, ISI marked, FRLSH type in green colour as continuous earth wire including all accessories and fixing arrengements, supporting clamps, bends, sockets and connecting items etc. all as specified and directed. Note - (a). Two runs of 2.5 Sqmm wiring cable and one run of 2.5 sqmm earth continuity wire with steel conduit shall be measured as as one length.
300
-
-
Material and labour for Sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, ISI marked, FRLSH type, 4.0 Sqmm, 1100 volts grade, drawn through and including New suitable size steel conduit including connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, ISI marked, FRLSH type, 2.5 sqmm, 1100 Volts grade, ISI marked, as earth contuinity wire all as specified and directed by Engineer in charge. (Note:- (i) Two runs of cables & continuous earth wire in new PVC casing and caping / PVC non metallic conduit will be measured as one length of sub main wiring).
220
-
-
Dismantling and drawing out old unserviceable Sub Main Aluminium/copper wiring from Existing Steel/PVC Conduit of any size and any type from any height with all connecting accessaries (excluding conduit or casing caping) and making good the disturbed wall and painting the same with matching to existing wall all as specified and directed by Engineer in charge.
3850
-
-
Material and labour Sub main wiring at any height including using 2 single core PVC insulated copper conductor cable (FRLSH) of size 1.5 sqmm 1100 volt grade drawn through existing Steel/ PVC conduit including 1.5 sqmm. PVC multi stranded copper conductor cable (FRLSH) in green colour for continuous earthing all as specified and directed. Note - (a). Two runs of 1.5 Sqmm cable and one run of earth continuity wire shall be measured as one length.
900
-
-
Material and labour Sub main wiring at any height including using 2 single core PVC insulated copper conductor cable (FRLSH) of size 2.5 sqmm 1100 volt grade drawn through existing Steel/ PVC conduit including 2.5 sqmm. PVC multi stranded copper conductor cable (FRLSH) in green colour for continuous earthing all as specified and directed. Note - (a). Two runs of 2.5 Sqmm cable and one run of earth continuity wire shall be measured as one length.
2500
-
-
Material and Labour for Sub main wiring at any height with 2 single core PVC insulated copper conductor cable (FRLSH) of size 4 sqmm 1100 volt grade drawn through Existing Steel / PVC conduit including 4.0 sqmm PVC multi stranded copper conductor cable (FRLSH) in green colour for continuous earthing all as specified and directed. Note - (a). Two runs of 4 Sqmm / 2.5 Sqmm wiring cable and one run of earth continuity wire shall be measured as one length.
450
-
-
Material and labour for Sub main wiring at any height and surface with and including four single core PVC insulated multi stranded copper conductor cable, ISI marked, FRLSH type, 6.0 Sqmm, 1100 volts grade, drawn through and including New PVC non metallic conduit including connected accessories and two single core PVC insulated multi stranded unsheathed copper conductor cable, ISI marked, FRLSH type, 6.0 sqmm, 1100 Volts grade, ISI marked, as earth contuinity wire all as specified and directed by Engineer in charge. (Note:- (i) Four runs of cables & continuous earth wire in new PVC casing and caping / PVC non metallic conduit will be measured as one length of sub main wiring).
180
-
-
Disconnecting and taking down old existing damaged metallic rigid steel conduit of any size and any type from any height with all fittings complete.
450
-
-
Supply & fixing hot galvanised rigid steel conduit 25 mm dia, light grade, at any height with and incld. of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks, screws, clips, plugs, clamps etc. for securing cables, battens, conduits etc. to walls, steel joists etc. complete to be fixed on wall/ceiling/MS angles all as directed by Engr-in-Charge.
250
-
-
Supply & fixing hot galvanised rigid steel conduit 20 mm dia, light grade, at any height with and incld. of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks, screws, clips, plugs, clamps etc. for securing cables, battens, conduits etc. to walls, steel joists etc. complete to be fixed on wall/ceiling/MS angles all as directed by Engr-in-Charge.
200
-
-
M & L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending colt or hot, drilling holes for bolts, at any height, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint for mounting Air Circulator / Exhaust Fan / Ceiling Fan for fixing arrangements complete.
1
-
-
Dismantling and Taking down unserviceable existing light fittings 1X 40 Watt / 2X 40 Watt of any size and capacity from any location/height after disconnecting of electrical connection complete including all connected accessories all as directed by Engr-in-Charge.
475
-
-
Supplying, fixing, connecting up to existing/new ceiling rose and testing surface mounting LED Tube Light Batten Fitting having extruded CRCA housing (heat sink) provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver suitable for and including 1x20 Watt 4 feet white colour tube lamp including connecting with 23/0.0076 copper conductor flexible twisted two core cable including all accessories (mounting SS clips) and fixing arrangements for fixing the light fitting on wall / steel trusses / false ceiling with 2 Nos. 19 mm dia rigid stove enamelled black steel conduit with bell mouth threaded sockets complete all as specified & directed including dismantling of old fittings.
140
-
-
Supplying, fixing, connecting in at any height up to existing/new ceiling rose and testing LED luminarie made up of precoated CRCA housing provided with cum reflector finished in white powder coating, completely prewired with accessories up to terminal block suiatble for 2x20 W LED tube 4' long including 02 Nos.20 W LED tubes with 23/0.0076 copper conductor flexible twisted two core cable and fixing arrangements for fixing the light fitting to steel trusses / false ceiling/ ceiling suspended by 2 nos. Ø19/20 mm rigid stove enamelled black steel conduit with bell mouth threaded sockets or with chains complete including dismantling of old fittings all as specified & directed.Make Polycab/Jaguar/crompton Greaves or equivalent Note for item No 41 and 42 -1 ; Stove enamelled black steel conduit or cahin only will be measured and paid under relevant items of this schedule. 2 ; Quoted rate is deemed to be inclusive of conduit fittings and bell mouthed threaded sockets.complete all as specified & directed. 3 ; Quoted rate is deemed to be inclusive any misc materials required for fixing new luminaries
150
-
-
Supplying, fixing, connecting in at any height up to existing/new ceiling rose and testing LED batten with 20 W LED light source in integral module with polycarbonate/Acrylic diffuser more than 85%efficiency of light with LED lamp efficay as 100 Lum/W THD ≤15% with operating voltage range 100-300V, driver efficency 85%, surge voltage withstand 2.5 KV , power factor ≥0.9, and connecting with 23/0.0076 copper conductor flexible twisted three/ two core cable fittings conection complete all as specified & directed. NOTE - Quoted rate is deemed to be inclusive of any misc materials required for fixing new luminaries.
160
-
-
Dismantling and taking down Highbay fittings 250/400W HPMV/MH/SV from a height upto 15 meters, replacing burnt/worn out accessories like holder, lamps, wires, ignitor, ballast, etc. complete at site.
150
-
-
Supply and fixing at 12 to 15 mtr height - 150W Industrial LED Highbay luminaire with 135 Lm/Watt ,Powder coated PDC Aluminium body & PC Optical Lenses. complete all accessories having IP 66 degree of protection, power factor CCT-5700k ANSI, CRI70, driver type isolated, potted Driver efficiency85 percent, PF0.95,THD10%,Internal Surge Protection-4KV & External Surge Protection-10KV,LED Source Make- Cree/Osram LED LIFE 50,000 RUNNING HRS
MOUNTING- WITH EYEBOLT PROTECTIONS- phase to phase 440 v for 2 hrs, reverse polarity, working temp- -10 deg to +50 deg INPUT VOLTAGE RANGE- 120V to 270 V
NABL certification- LM79 including connection with and including 1.00 sqmm three core cable from connector or ceiling rose to light fitting complete all as specified and directed by Engineer-in-Charge NOTE :- The quoted rates are deemed to be included the cost of Nut-bolts washars or clamps required to be replaced if old one are found unserviciable or of diferant size/shape for completion of work.
150
-
-
Disconnecting and taking down old switch fuse type distribution Box with MCB/fuse grip TPN/SPN DB 2 Way to 12 Way old type DB including taking out all cable connections of any description and in any position and making good the disturbed surface of walls, to match with the existing surfaces complete all as specified and directed by Engineer in charge.
46
-
-
S&F, connecting & testing of VTPN DB of 12 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet, shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damage like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed. Note : MCCB , MCB will be measured and paid separately under relevant item of this schedule.
2
-
-
S&F, connecting & testing of VTPN DB of 8 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet, shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damage like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed. Note : MCCB , MCB will be measured and paid separately under relevant item of this schedule.
10
-
-
S&F, connecting & testing of VTPN DB of 4 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet, shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed. Note : MCCB, MCB will be measured and paid separately under relevant item of this schedule.
14
-
-
S&F, connecting & testing SPN DBs of 8 way for using MCBs / MCB isolators suitable for single pole and neutral, with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet, shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 10kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed.
12
-
-
S&F, connecting & testing SPN DBs of 12 way for using MCBs / MCB isolators suitable for single pole and neutral, with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet, shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 10kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed.
8
-
-
Supplying & fixing in replacement MCCB 125 Amps, 4 pole, 25 kA breaking capacity with thermal magnetic release (adjustment - 0.8 to 1 In) having Ics = 100% Icu complete with and inclusive of spreader terminals all as specified and directed.
14
-
-
Supplying & fixing in replacement MCB 40 to 63 Amps, 3P/4P, 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly, biconnect lower terminals, IP 20 protected terminals, sliding shutters complete all as specified and directed.
45
-
-
Supplying & fixing in replacement MCB 6 to 32 Amps, single pole and neutral, 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly, biconnect lower terminals, IP 20 protected terminals, sliding shutters complete all as specified and directed.
45
-
-
Supplying & fixing in replacement MCB 6 to 32 Amps, single pole, 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly, biconnect lower terminals, IP 20 protected terminals, sliding shutters complete all as specified and directed.
305
-
-
M&L MS box 8 module, 8x3 inch size with with 3 mm thick hylum sheet cover flushed with and including 01 No. dimmer controller, 450 W, 240 V, 50 Hz, pre wired, 01 No. 5/15 Amps socket, 01 No. 15 Amps piano switch and 01 No. 15 Amps plug top, all to be mounted on MS 'C' Channel. NOTE - Quoted rate is deemed to be inclusive of fixing arrangements of box and including dismantling of old unsv box.
60
-
-
Supplying, fixing, connecting up to existing/new ceiling rose and testing 36 W aesthetically designed 2x2 LED recess mounting in grid/armstrong type ceiling including suitable LED driver and connecting with 23/0.0076 copper conductor flexible twisted two core cable to existing/new ceiling rose and including mounting accessories complete all as specified & directed.
25
-
-
Supplying, fixing, connecting up to existing/new ceiling rose and testing 36 W aesthetically designed 2x2 LED surface mounting in grid/armstrong type ceiling including suitable LED driver and connecting with 23/0.0076 copper conductor flexible twisted two core cable to existing/new ceiling rose and including mounting accessories complete all as specified & directed.
24
-
-
Evaluation Notes How It Works ?