Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date4 Dec 2024
Closing Soon24 Dec 2024
Tender Amount₹ 43,00,000
Costs
EMD
₹ 86,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_687011_1Tender No
8201/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade, armoured, heavy duty LT UG cable of size 240 Sqmm, 3.5 core with XLPE insulated stranded aluminium conductor including cable gland, lugs, testing and commissioning including taking out existing cable alongwith protection covers complete all as specified and as directed.
30
-
-
... More
All as per serial item No 4 but cross sectional area 185 sq mm, 3.5 core.
30
-
-
... More
All as per serial item No 4 but cross sectional area 120 sq mm, 3.5 core.
150
-
-
... More
All as per serial item No 4 but cross sectional area 95 sq mm, 3.5 core.
60
-
-
... More
All as per serial item No 4 but cross sectional area 70 sq mm, 3.5 core.
30
-
-
... More
All as per serial item No 4 but cross sectional area 50 sq mm, 3.5 core.
60
-
-
... More
All as per serial item No 4 but cross sectional area 35 sq mm, 3.5 core.
150
-
-
... More
All as per serial item No 4 but cross sectional area 25 sq mm, 3.5 core.
660
-
-
... More
All as per serial item No 4 but cross sectional area 10 sq mm, 2 core.
2850
-
-
... More
M&L in repairs for straight through cable jointing kit, heat shrinkable for 1.1 KV grade, 25 to 50 sqmm 3.5 core, XLPE cable with jointing material and accessories and testing after jointing all as specified and as directed.
11
-
-
... More
All as per serial item No 13 but for 70 to 120 sqmm, 3.5 core XLPE cable
3
-
-
... More
Supply and lay DWC Cable duct pipe of size 50 mm dia confirming to IS : 16205 part 24 for laying of LT cables etc complete with all accessories all as specified and directed.
2650
-
-
... More
Supply and lay DWC Cable duct pipe of size 60 mm dia confirming to IS : 16205 part 24 for laying of LT cables etc complete with all accessories all as specified and directed.
60
-
-
... More
Supply and lay DWC Cable duct pipe of size 110 mm dia confirming to IS : 16205 part 24 for laying of LT cables etc complete with all accessories all as specified and directed.
90
-
-
... More
S&F in repairs, 50 mm bore dia GI pipe, light grade, laid in trenches / fixed to Pole / wall for cable protection complete all as specified and as directed.
18
-
-
... More
S&F in repairs, 80 mm bore dia GI pipe, light grade, laid in trenches / fixed to Pole / wall for cable protection complete all as specified and as directed.
18
-
-
... More
S&F in repairs, LED flood light fitting, 70 watt, 230V AC outdoor type with thermal management in multiple optics and equipped with IP65/66 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
10
-
-
... More
S&F in repairs, LED street light fitting, 100 Watt, 230 Volt, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp, braket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection all as specified and as directed.
10
-
-
... More
S&F in repairs, LED street light fitting, 40 Watt, 230 Volt, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp, braket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection all as specified and as directed.
44
-
-
... More
S&F in repairs, LED street light fitting, 60 Watt, 230 Volt, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp, braket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection all as specified and as directed.
50
-
-
... More
S&F in repairs, LED post top lantern, 20 watt, 230 Volt AC with decorative post top 360 degree indirect light, IP 65 protection with impact and corrosion resistant complete all as specified and as directed.
22
-
-
... More
S&F in repairs, Automatic street light switch, using infra-red sensor based NATURE SWITCH for automatic switching of street lights. Nature switch operation should be based on Natural light Lux*level. Required llluminance Level for switching ON is _60Lux and for Switching OFF_10Lux. The sensor should also have part night operation facility of minimum 4 hrs to maximum 12 hrs , The Sensor along with suitable Power Contactor(s) and Incoming-outgoing MCBs and Auto -manual (sensor By-pass) selection option should be enclosed in a pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade SMC junction box/ Enclosure conformig to IP 54 with suitable steel clamps,nuts, bolts for installation on pole complete as directed. The circuit should be suitable enough to take single phase load of 5 - 8 KW (swadeep-02EC-5KW1P) with contactor ,incoming MCBs,outgoing MCBs rating of 40-63 Amps and main load circuit wiring (copper cable) of min 10 sqmm all as specified and as directed.
Make :- (a) Nature switch : Kakatiya Energy Systems/Bajaj/Healer, (b) Contractor : L&T, conform to IEC -60947-4-1 /IS-13947-4-1 (c) MCB : L& T, conform to IEC-60898 /IS-8828 (d) Enclosure & Circuit Sheet : Sintex or Equivalent as approved from list of makes specified in tender documents, (e) Circuit wiring : Polycab/Finolex
8
-
-
... More
S&F in repairs, 4 pole MCCB, 250 amps, 50 KA, 415 Volts, with adjustable type settings all as specified and as directed.
2
-
-
... More
All as per serial item No 26 but MCCB 200 Amps, 36 KA
3
-
-
... More
All as per serial item No 26 but MCCB 160 Amps, 36 KA
2
-
-
... More
All as per serial item No 26 but MCCB 125 Amps, 25 KA
3
-
-
... More
All as per serial item No 26 but MCCB 25 to 100 Amps, 25 KA
3
-
-
... More
M&L for PCC 1:4:8, type D2, using 40 mm graded stone aggregates as in foundation of pole/stays all as specified and as directed.
4.6
-
-
... More
M&L for PCC 1:3:6, type C1, using 20 mm graded stone aggregates as in coping of pole and similar work etc including necessary formwork and finishing even and smooth without using extra cement complete all as specified and as directed.
106
-
-
... More
M&L for cutting the existing bituminous road / PCC hard standing upto 75cm in depth, 60cm in width, getting out excavated materials and making good the damaged portion after laying of cables/ pipes by returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick and PCC 1:2:4 type B1 using 20mm graded stone aggregate upto 30cm depth from top of the road all as specified and as directed.
26
-
-
... More
Labour and machine required for locating fault in U/G cable 11 KV by using fault detector machine including transportation and by carring out high pressure test all as directed by Engr-in-charge
2
-
-
... More
Labour and machine required for locating fault in U/G LT cable 1100 volts by using fault detector machine including transportation and by carring out high pressure test all as directed by Engr-in-charge
2
-
-
... More
Labour for cutting/trimming the tree branches 3 mtr adjacent to the LT/HT OH lines/street light feeder on bothe sides and removing the the same to out side and disposing same complete all as direcetd
165
-
-
... More
M&L earthing complete as per electrical plate No.3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 32mm x 6mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 32mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete.
8
-
-
... More
S&F cross arms, bracings, support channel, back plate hooks etc fabricated from structural steel, sections (MS Channel) of required size and shape including nuts, bolts,washers, welding, bending , cutting cold or hot, drilling holes for inserting bolts as indicated and directed including painting with one coat of red oxide primer and two coats of silver aluminium paint including dismantling existing cross arms, MS Channel or angle section complete all as specified and as directed.
1
-
-
... More
M&L for aluminium conductor steel reinforced (ACSR), any size, (Weasel/Ferret/Squirrel as required) including stringing, binding, jointing, jumpering etc on insulators or on poles with minimum sag complete including dismantling ACSR conductor from LT/HT pole all as specified and as directed.
1
-
-
... More
S&F pin type porcelain vitreous brown/white insulator with approved make including one galvanised MS spindle two GI Washers and GI nut of size 100 mm height and 65 mm dia 1100 Volt grade including taking out old unserviceable insulator complete all as directed
10
-
-
... More
All as per serial item 40 but size 150mm dia , 150 mm height for 11000 Volts grade.
10
-
-
... More
S&F shackle type, porcelain, vitreous, brown/white insulator of size 75 mm height, 90mm dia with approved make including galvanised MS strip of section 31 mm x 3 mm, insulated bolts 12mm dia, washers, nut etc for working pressure 1100 volt grade, including taking out of old unserviceable insulator complete all as directed.
10
-
-
... More
S&F single disk assembly insulator, porcelain, vitreous, 145mm high and 225 mm dia, and socket type white, brown or green with all acessories including taking out of old unserviceable insulator complete all as directed.
8
-
-
... More
Unbinding of the ACSR conductor from insulator on pole, pruning tree branches 3 mtr all arround conductor and restringing ACSR conductor of 2 to 6 conductors, tightening of OH Lines, binding to the insulators using required size of aluminium binding wire complete all as directed by Engr-in-charge .
30
-
-
... More
Dismantling old existing ACSR conductor of any type/size all as specified and directed.
4
-
-
... More
Dismantling old existing GI earth wire of any size complete all as specified and directed.
1
-
-
... More
Dismantling old existing MS cross arms of any type/shape all as specified and directed.
4
-
-
... More
Dismantling old existing Insulators of any type/shape all as specified and directed.
60
-
-
... More
Dismanthing/taking down carefully the defective street light/security light/ floodlight fittings/ Post top lanterns of any description and servicing/ cleaning, checking connections, replacement of unserviceable spares, reassembling and refixing at its original location including reconnections and testing / commisssioning complete all as directed. Note: (i) Spares to be replaced shall be measured separately under relevant items of schedule.
(ii) Cost of minor parts like screws, nut bolts, washers, pieces of wires and insulation tape etc required on site is deemed to be included in the quoted rates.
100
-
-
... More
S&F in repairs, LED Drivers for 30 W LED Security light fittings any type and any make as per sample, all as specified and as directed.
20
-
-
... More
S&F in repairs, LED Drivers for 50 W LED Security light fittings any type and any make as per sample, all as specified and as directed.
20
-
-
... More
S&F in repairs, LED Drivers for 60 W LED Security light fittings any type and any make as per all as specified and as directed.
30
-
-
... More
S&F in repairs, LED Drivers for 90 W LED Security light fittings any type and any make as per all as specified and as directed.
30
-
-
... More
S&F in repairs, LED Drivers for 120 W LED Flood light fittings any type and any make as per sample, all as specified and as directed.
20
-
-
... More
S&F in repairs, LED surge protectors for exisiting Size/Capacity LED fittings any type and any make as per sample, all as specified and as directed.
30
-
-
... More
Supply and fix in repairs brackets made out of 40mm bore GI pipe, light grade, 1.5M long, bend to shape and including suitable MS clamps made out of 40 x 6mm flat iron, necessary bolts, nuts, washers etc complete and painting the bracket and clamps with 2 coats of synthetic enamel paint over a coat of red oxide Zinc chromate primer all as specified and directed.
10
-
-
... More
S & F PVC weather proof, hinged door, junction box with 10A Aluminium bus bar, 240V, Neutral link and 1No MCB SP of 6Amps, necessary fixing arrangement such as clamps, nut, bolts, etc including dismantling old u/s JB all as specified and directed.
50
-
-
... More
M & L for painting of poles including cross arms, channels, clamps etc by scrapping old paints and applying two coats of aluminium paint over a coat of red oxide primer and writing Pole No in black paint etc complete all as specified and directed by Engr- in -Charge.
145
-
-
... More
M & L for painting of two pole structure including cross arms, channels, clamps etc by scrapping old paints and applying two coats of aluminium paint over a coat of red oxide primer and writing Pole No in black paint etc complete all as specified and directed by Engr- in -Charge.
3
-
-
... More
M & L for painting of four pole structure including cross arms, channels, clamps etc by scrapping old paints and applying two coats of aluminium paint over a coat of red oxide primer and writing Pole No in black paint etc complete all as specified and directed by Engr- in -Charge.
2
-
-
... More
Supply install in replacement and testing out door wheather proof bus bar chamber of size 100 cm x 60cm x 30cm made out of 3.15mm CRCA MS sheet having one side openable hinged door shuter with looking arangement/provn of two nos 80cm long 40x40x6mm anlge iron legs welded and 04 nos copper bus bar of 200Amp rating provn of one MCCB 4 pole 160 Amp 25 KA for controlling Electric supply complete erracted on ground with necessary PCC 1:3:6 type C2 foundation complete bus bar chamber painted with two coats of approved enamel paints over one coat of primer including making cable connection with necessary gland , lugs/thimbles with framework 1000mm (W) X 600mm (H) X 300mm (D) all as specified and as directed.
2
-
-
... More
Supply and fixing LT cable route indicator cast iron of suitable size with height of 1.5 metre along with LT cable trench including planting in ground with PCC complete all as specified and directed.by Engr-in-Charge.
59
-
-
... More
Supply and fixing PVC insulated and over all PVC sheathed, stranded copper conductor wire 1.5 sqmm x 3 core ISI marked.complete from fitting to pole junction box complete all as specified.
480
-
-
... More
M&L for 4 sqmm 2 core, 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat stranded conductor including taking down old unserviceable cable all as specified and as directed.
270
-
-
... More
All as per serial item No 64 but 10 sqmm, 2 core
150
-
-
... More
All as per serial item No 64 but 6 sqmm, 2 core
90
-
-
... More
Supply, install, testing and commissioning factory made and tested (including CPRI type test certified) LT Panel box (Design as approved by GE), outdoor type, floor mounted, compartmantalised and IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated copper bus bars installed on porcelain insulators. The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet and with base frame of 40x40x6mm angle iron 45 cm above ground and 45cm grounted in ground with PCC 1:2:4 Type B1 and coping 30cm above ground level,well Ventilated , powder coated, Front and rear opening type with aprons for cable entry with double door shutter and locking arrangement and including dismantling/ taking down old unserviceable LT feeder piller box with framework 1250mm (W) X 1000mm (H) X 500mm (D) all as specified and as directed. Location : Near office guard room back side
1
-
-
... More
Incoming : (a) MCCB 250 amps, 4 pole, 36 KA, 415 volts grade, with thermal magnetic - 01 No (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 400 Amp, 4 pole, mounted on insulators for incomming supply - 01 Set. (c) digital Volt meter ,415 volts, 50 Hz AC supply -01 set. (d) digital Amp meter ,415 volts, 50 Hz AC supply -01 set. (e) Neon indicating lamps (R, Y & B) -01 Set. (f) Control MCB 1P 6 Amp - 04 No , (g) CT 200/5 - 01 No Outgoing : (a) MCCB 100 amps, 4 pole, 36 KA, 415 volts grade, with thermal magnetic - 01 No (b) digital Volt meter ,415 volts, 50 Hz AC supply -01 set. (c) digital Amp meter ,415 volts, 50 Hz AC supply -01 set. (d) Neon indicating lamps (R, Y & B) -01 Set. (e) MCB SPN 32 amps, 10 KA, 230 volts grade - 06 Nos
-
-
-
... More
Supply, install, testing and commissioning factory made and tested (including CPRI type test certified) LT Panel box (Design as approved by GE), outdoor type, floor mounted, compartmantalised and IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated copper bus bars installed on porcelain insulators. The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet and with base frame of 40x40x6mm angle iron 45 cm above ground and 45cm grounted in ground with PCC 1:2:4 Type B1 and coping 30cm above ground level,well Ventilated , powder coated, Front and rear opening type with aprons for cable entry with double door shutter and locking arrangement and including dismantling/ taking down old unserviceable LT feeder piller box with framework 1250mm (W) X 1000mm (H) X 500mm (D) all as specified and as directed. Location : Near CVTI Bld
1
-
-
... More
Incoming : (a) MCCB 200 amps, 4 pole, 36 KA, 415 volts grade, with thermal magnetic - 01 No (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 600 Amp, 4 pole, mounted on insulators for incomming supply - 01 Set. (c) digital Volt meter ,415 volts, 50 Hz AC supply -01 set. (d) digital Amp meter ,415 volts, 50 Hz AC supply -01 set. (e) Neon indicating lamps (R, Y & B) -01 Set. (f) Control MCB 1P 6 Amp - 04 No ,(g) CT 200/5 - 05 No Outgoing : (a) MCCB 160 amps, 4 pole, 36 KA, 415 volts grade, with thermal magnetic - 01 No (b) MCCB 25 to 100 amps, 4 pole, 36 KA, 415 volts grade, with thermal magnetic - 05 No (c) digital Volt meter ,415 volts, 50 Hz AC supply -06 set. (d) digital Amp meter ,415 volts, 50 Hz AC supply -06 set. (e) Neon indicating lamps (R, Y & B) -06 Set.
-
-
-
... More
M&L for monthly 'A' Check Inspection, maintenance and serviceing DG sets, 125 KVA Capacity, Make : kirloskar oil engines, Model 6R 1080TA, Location : AC Depot Pump House, including alternator, electric panel board connection to DG set etc for smooth functioning and carrying out following maintanance as required at site and directed by Engr-in Charge. Note: Items/ Spares required shall be measured and paid separately under respective item of BoQ
(i) Checking engine oil level and topping up as and when required. (ii) Checking and adjusting the belt for tension and replacement of belt if required. (iii) Checking of oil bath air cleaner level (iv) Checking of exhaust system for leakage (v) Draining of sediment from fuel filter and fuel tank (vi) Cleaning of air cleaner elements (vii) Checking engine alternator coupling, mounting bolts and alignment (viii) Tighting all nuts, bolts, in altenator terminal block (ix) Checking of alternator carbon brushes and connections in alternator (x) Checking and tightening of all connection in DC control wiring. (xi) Checking of all radiator rubber hoses for leakage and replacement if required. (xii) Checking and recording oil pressure, water and oil temperarute for smooth functioning. (xiii) Checking anti vibration mounting pads for any deformation. (xiv) Checking throttle linkage for smooth operation. (xv) Checking battery for cell test, electrolyte level, gravity and topping up to required level (xvi) Routine check / repair work of panel, switches, MCCBs, main switch, all contactors, engine control unit etc. (xvii) Checking of AMF panel, all electrical connections etc. (xviii) Checking of earthing resistance (xix) Cleaning of vegitation around the DG set up to 1.5 mtr area.
9
-
-
... More
All as per serial item No 69 but DG set 100 KVA Capacity, Make : kirloskar Green, Model KG-225L, Location : New KLP Pump house
9
-
-
... More
All as per serial item No 69 but DG set 160 KVA Capacity, Make : Crompton Greaves Ltd, Model SDAG 2210, Location : New KLP Pump house
9
-
-
... More
All as per serial item No 69 but DG set 160 KVA Capacity, Make : kirloskar oil engines, Model KG 160 SGIR250MAL, Location : Dhobhighat pump house
9
-
-
... More
All as per serial item No 69 but DG set 160 KVA Capacity, Make : kirloskar oil engines, Model KG 160 SGIR250M, Location : Dhobhighat pump house
9
-
-
... More
All as per serial item No 69 but DG set 200 KVA Capacity, Make : Kirloskar, Modal KG 254M-1 Location :DAD complex
9
-
-
... More
All as per serial item No 69 but DG set 320 KVA Capacity, Make : Crompton Greaves Ltd, Model F-GIR 315 SB EKG-1049, Location : Bhinghar pump house
9
-
-
... More
All as per serial item No 69 but DG set 320 KVA Capacity, Make : Crompton Greaves Ltd, Model F-GIR 315 SB EKG-1049, Location : Bhingar pump house
9
-
-
... More
M&L for 'B' Check once in Six month OR 250 Hrs running whichever is earlier for DG sets of 125 KVA Capacity, Make : kirloskar oil engines, Model 6R 1080TA, Location : AC Depot Pump House, Inspection, maintenance and serviceing including alternator, electric panel board connection to DG set etc for smooth functioning and carrying out following maintenance as per OEM instructions and as directed by Engr-in-Charge.
Note: Items/ Spares including 'B' Check kit, coolent, lubricating oil required shall be measured and paid separately under respective item of BoQ. (i) Repeat the activities of 'Á' Check services (ii) Replacment of lubricant oil. (iii) Replacing lubricant oil filters element with O rings (iv) Replacing fuel filters element with O rings (v) Replacing air filter elements with O rings (vi) Replacing coolant.
2
-
-
... More
All as per serial item No 77 but for DG set 100 KVA Capacity, Make : kirloskar Green, Model KG-225L, Location : New KLP Pump house
2
-
-
... More
All as per serial item No 77 but DG set 160 KVA Capacity, Make : Crompton Greaves Ltd, Model SDAG 2210, Location : New KLP Pump house
2
-
-
... More
All as per serial item No 77 but for DG set 160 KVA Capacity, Make : kirloskar oil engines, Model KG 160 SGIR250MAL, Location : Dhobhighat pump house
2
-
-
... More
All as per serial item No 77 but for DG set 160 KVA Capacity, Make : kirloskar oil engines, Model KG 160 SGIR250M, Location : Dhobhighat pump house
2
-
-
... More
All as per serial item No 77 but for DG set 200 KVA Capacity, Make : Kirloskar, Modal KG 254M-1 Location :DAD complex
2
-
-
... More
All as per serial item No 77 but for DG set 320 KVA Capacity, Make : Crompton Greaves Ltd, Model F-GIR 315 SB EKG-1049, Location : Bhinghar pump house
2
-
-
... More
All as per serial item No 77 but for DG set 320 KVA Capacity, Make : Crompton Greaves Ltd, Model F-GIR 315 SB EKG-1049, Location : Bhinghar pump house
2
-
-
... More
Supply only 'B' check kit for DG set 125 KVA Capacity, Make : kirloskar oil engines, Model 6R 1080TA, Location : AC Depot Pump House. Note : Quoted rate includes oil filters (1.00 Ltr/0.5 ltr), Diesel filters, air filters inner and outer as recommended by OEM
2
-
-
... More
All as per serial item No 85 but for DG set 100 KVA Capacity, Make : kirloskar Green, Model KG-225L, Location : New KLP Pump house
2
-
-
... More
All as per serial item No 85 but DG set 160 KVA Capacity, Make : Crompton Greaves Ltd, Model SDAG 2210, Location : New KLP Pump house
2
-
-
... More
All as per serial item No 85 but for DG set 160 KVA Capacity, Make : kirloskar oil engines, Model KG 160 SGIR250MAL, Location : Dhobhighat pump house
2
-
-
... More
All as per serial item No 85 but for DG set 160 KVA Capacity, Make : kirloskar oil engines, Model KG 160 SGIR250M, Location : Dhobhighat pump house
2
-
-
... More
All as per serial item No 85 but for DG set 200 KVA Capacity, Make : Kirloskar, Modal KG 254M-1 Location :DAD complex
2
-
-
... More
All as per serial item No 85 but for DG set 320 KVA Capacity, Make : Crompton Greaves Ltd, Model F-GIR 315 SB EKG-1049, Location : Bhinghar pump house
2
-
-
... More
All as per serial item No 85 but for DG set 320 KVA Capacity, Make : Crompton Greaves Ltd, Model F-GIR 315 SB EKG-1049, Location : Bhinghar pump house
2
-
-
... More
Supply & Refiling coolent, K cool super plus 50-50 Premix all as specified and as directed.
200
-
-
... More
Supply & Refiling Battery water with electrolyte mix all as specified and as directed.
60
-
-
... More
Supply & Refiling Engine oil 20 W 40 turbo synthetic superior quality engine oil all as specified and as directed.
400
-
-
... More
S&F radiator hose pipe set with clamps suitable for DG set of capacity 100 /125 KVA all as specified and as directed.
4
-
-
... More
S&F radiator hose pipe set with clamps suitable for DG set of capacity 160/200 KVA all as specified and as directed.
4
-
-
... More
S&F radiator hose pipe set with clamps suitable for DG set of capacity 320 KVA all as specified and as directed.
4
-
-
... More
S&F fan belt set suitable for 100/125 KVA all as specified and as directed.
2
-
-
... More
S&F fan belt set suitable for 160/200 KVA all as specified and as directed.
3
-
-
... More
S&F fan belt set suitable for 320 KVA all as specified and as directed.
2
-
-
... More
S&F in replacement of battery lead with Negative & Positive brass terminals of suitable size and length of each lead all as specified and as directed.
6
-
-
... More
Servicing & repair to self starter of DG set of 100 KVA to 320 KVA including replacement of parts such as washer, nut, bolts, bush, solonoid, rotor etc. assembling and testing complete all as directed by Engr-in-Charge.
3
-
-
... More
S&F in replacement of battery 12 V, 180 AH, maintenance free battery, 12 Volt initially charged with suitable size of copper leads and brass terminals complete as directed by Engr-in-Charge. Make: Excide/ Amara Raja/ Luminous
4
-
-
... More
M&L in repairs and replacement of broken conopy door hinges of DG set of any capacity and make. Setting of conopy door, properly locking arrengement complete all as directed by Engr-in Charge
2
-
-
... More
M&L in repairs and replacement for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including galvanized earth strip 25mmx4mm upto 7.5 m by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 32mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, charcoal,salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified and as directed.
2
-
-
... More
S&F in replacement of fuel level gauge of DG set as per existing make, model complete all as directed by Engineer-in-Charge.
2
-
-
... More
M&L for dismantling, transportation to workshop and back, opening, rewinding main winding assembly and refixing 100 to 320 KVA DG set alternater, three phase, 415 V, 50 Hz with super enameled copper wire of existing gauge and existing class insulation including superior quality varnishing, heating / drying coils, making connections from coil to terminal box, spray painting with two coats of synthetic enamel paint including repair/replacement of diode plates for neutral & phase and repair / replacement of AVR, connecting, testing and commissioning at site for satisfactorily operation as required and directed by Engr-in-Charge..
1
-
-
... More
S&F in replacement of Alternator connection terminal block suitable for 100 to 320 KVA DG Set alternetor as per existing sample complete all as directed by Engr-in Charge.
1
-
-
... More
M&L in replacement of battery stand frame of size 4 feet x 1.5 feet with height of 1 feet made of 50mm x 50mm x 6mm angle iron and support with flat iron of size 40mm x 6mm, duly painted with two coats of synthetic enamel paint over one coat of red oxide primer, 20 mm wooden plank on top to place 02 Nos batteries complete all as specified and as directed by Engr-in-Charge.
1
-
-
... More
Dismaintling, radiator assembly from the engine of 200/320 KVA DG set by disconnecting inlet and out let connections , overhauling/ servicing the radiator , clearing, removing blockages arresting leakages, assembling back incl necessary welding brazing as required , refixing , reconnecting and testing for proper functioning :
3
-
-
... More
All as per serial item No 111 but for 160 KVA DG set Make : KIRLOSKAR Model 6 SL 1500TA.
2
-
-
... More
All as per serial item No 111 but for 160 KVA DG set , Make : Crompton Greaves Ltd, Model SDAG 2210
1
-
-
... More
All as per serial item No 111 but for 125 KVA DG set Make KIRLOSKAR Model 6 SL 9088T
1
-
-
... More
All as per serial item No 111 but for 100 KVA DG set Make KIRLOSKAR Model 6 SL 9088T/Model no. KG100W52
1
-
-
... More
S&F in repairs, fuel level indicator pipe white transparent including two jublee clamps, marking level with radiem paint/ tape complete all as specified and as directed
2
-
-
... More
S&F in repairs, exhaust pipe white asbestos rope including removing old unservicable rope all as specified and as directed
48
-
-
... More
S&F in repairs, MCCB, 3 Pole,400 Amps, capacity 50 Hz, 415 volts with rating 36 KA and connection with proper Lugs all as specified and as directed
1
-
-
... More
S&F in repairs, MCCB, 3 Pole 250 Amps, capacity 50 Hz, 415 volts with rating 36KA and connection with proper Lugs all as specified and as directed
1
-
-
... More
S&F in repairs, MCCB, 3 Pole 200 Amps, capacity 50 Hz, 415 volts with rating 36 KA and connection with proper Lugs all as specified and as directed
2
-
-
... More
S&F in repairs, MCCB, 3 Pole 160 Amps, capacity 50 Hz, 415 volts with rating 36 KA and connection with proper Lugs all as specified and as directed
2
-
-
... More
S&F in repairs, automatic voltage regulator Kit suitable for 100/125 KVA alternator including incoming and out going cable connection and tesring on completion all as specified and as directed
1
-
-
... More
S&F in repairs, flexible love-joy coupling set with Nut/ Bolt and rubber bushes suitable for existing DG set including metal filling grinding, finishing to suit the site installation alinging for noise free function all as specified and as directed
2
-
-
... More
S&F in repairs, rubber bushing/rubber spider of DG set coupling complete with Nut , bolt and washer all as per site requirement and as directed by Engineer - in - charge .
4
-
-
... More
M&L in replacement of battery charger 12 V DC SMPS 10 Amp for AMF panel all as specified and as directed
2
-
-
... More
Supply and topping up / replacement of insulating oil of stabilizer chamber with new insulating / transformer oil upto the required level in any type and capacity of the voltage stabilizer all as directed by Engineer-in-Charge. Note : Insulating / transforemer oil brought by the contractor at site must be in seal packed in drum having ISI mark as per IS-335 / 1983. Make : Savita / Asian.
200
-
-
... More
Repair / Servicing to voltage stabilizers 3 phase 4 wire system, 160 to 300 KVA by at site by opening carefully from top, taking out coils / connections, cleanig coils checking defective joints / soldering / jointing, re- assembling and testing on full load and making fully servicable including spray painting with supper enamelled paint of colour as directed by EIC, complete all as specified and directed.
3
-
-
... More
S&F in repairs, off load change over switch 100 TO 200 Amps, 4P, 415 V suitable for LT PANEL all as specified and as directed
1
-
-
... More
S&F in repairs, off load change over switch 250 TO 400 Amps, 4P, 415 V suitable for LT PANEL all as specified and as directed
1
-
-
... More
M&L for repair and replacment of unserviceable time switch accessories/ spares including reconnecting and testing complete all as specified and as directed.
Note : - Spares/accessories required for replacement shall be measured and paid sepratley under respective items of BoQ.
3
-
-
... More
S&f in repairs, time switch analog type, single phase, 230 Volts of rating 20 Amps all as specified and as directed.
3
-
-
... More
S&F in repairs, contactor, 40 amps, 4 pole, 415 volts fixing with existing box by suitable size of copper cable with suitable size of lugs all as specified and as directed.
3
-
-
... More
S&F in repairs, contactor, 63 amps, 4 pole, 415 volts fixing with existing box by suitable size of copper cable with suitable size of lugs all as specified and as directed.
3
-
-
... More
S&F in repairs, MCB TPN 16-32 Amps, 415 Volts, 50 Hz AC supply system all as specified and as directed.
3
-
-
... More
S&F in repairs, MCB TPN 40-100 Amps, 415 Volts, 50 Hz AC supply system all as specified and as directed.
3
-
-
... More
M&L in repairs/replacement for earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to the GI wire 4 mm dia , by means of nut bolts, check nuts and washer of the GI . Earth wire connected upto main earth point/DBs alongwith 15mm dia GI pipe, medium grade, including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40 mm thick RCC (1:2:4) cover with reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified including testing on completion.
3
-
-
... More
S&F in repairs, NG Series AIO LED solar street light fitting 40 watt is made with high efficiency mono crystalline solar PV module, lithium ferro phosphate battery with in - built BMS technology, high efficacy LED, MPPT solar charge controller and aluminium extuded body & is specially programmed to automatically control the dimming and brightness of light, which increases the backup time, including galvanised steel pole 80mm bore dia 6 m long, embedded in PCC 1:2:4, type B2 concrete, excavation and earthwork complete all as specified and as directed. Make of LED solar street light fitting : Havells Cat Part No :SOLAR AIO 40 W or equivalent model of make Philips / GE/ Crompton/ Ptronics/Century LED/ SYSKA
3
-
-
... More
M&L in repairs/replacement of battery charger, 24 V DC SMPS 10 Amp for AMF panel all as specified and as directed.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%