Military Engineer Services Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date27 Dec 2024
Closing Date23 Jan 2025
Tender Amount₹ 75,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
TENDER INVITING FOR REPAIR/REPLACEMENT AND MAINT OF EXTERNAL ELECTRIFICATIONS INCLUDING PANELS, GODs, CABLES, POLES AND CONNECTED WORKS AND WORKS AT E/M INSTALLATIONS IN AOR OF AGE E/M UNDER GE NASIK ROAD
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the Engineer - in - Charge.

400

-

-

... More
Disconnecting & taking out cable LT 1100V grade any size complete all as specified.

100

-

-

... More
Supply, fixing and laying in trenches or fixing or passing through pipe, 1100 Volts grade heavy duty LT UG cable, 3.5 core 240 Sqmm, with XLPE insulated stranded Aluminium conductor served with an inner sheathing of PVC tape, Armoured with galvanised steel strip and overall sheathed including cable gland, lugs, jointing material etc, jointing, connecting, testing and commissioning all as specified and directed.

100

-

-

... More
Supply and fixing in replacement of galvanized earth strip 32 mm x 6 mm for earthing from earth plate to equipment complete fixed on pocelain insulator every 1 meter interval all as specified and as directed.

200

-

-

... More
Supply and filling oil of approved quality ISI marked for filling 33 KV potential transformer/Current Transformer.

20

-

-

... More
Material and labour in repair for top cover including replacement of cork sheet,/gasket, tightening of nut bolt, washers etc for 33 KV potential transformer.

1

-

-

... More
M&L for Dehydration of tranformer oil, obtained from transformers /voltage stabilizer/OCBs etc. Dielctric strength shall not be less than 40 KV in 2.5 mm gap electrode after dehydration. Dehydration of transformer shall be carried out by using electrically operated dehydration machine and topping up/ replacement of unserviceable transformer oil complete all as directed. Note :- Filteration of transformer oil shall be in off load position of transformer.

5000

-

-

... More
Supply and filling transformer oil of approved quality ISI marked for filling in transformer for topping up/ replacement in transformer comlete all as directed by Engr-in-Charge. Note: (i) Dielectric strength of transformer oil not less than 40 kv with 2.5mm gap. (ii) New transformer oil filled to transformer after filtration only, rate for filtration deemed include in the quoted rate. iii) Oil for filling shall be brought to site in sealed barrel only.   (Make: Power/Castrol/Servo)

600

-

-

... More
Supply, fixing and connecting in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed.

4

-

-

... More
Supply, fixing and connecting in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed.

4

-

-

... More
Supply, laying, jointing and testing in replacement of XLPE insulated, screened, PVC bedded galvanised steel strip armoured electric power cable (heavy duty) with aluminium conductor, 11000 Volts Earthed grade 3 Core 95 Sqmm, laid in trenches, ducts, along pole, along Transformer complete all as specified and directed.

1500

-

-

... More
Supply, fixing and connecting in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed.

12

-

-

... More
Material and labour for Double Walled Corrugated DWC HDPE Pipe of outer dia 50mm and inner dia 38mm including 90 degree bends with coupler and rubber ring laid in trenches/ on wall/ on pole for earth strip protection complete all as specified and directed.

80

-

-

... More
Material and labour for Double Walled Corrugated DWC HDPE Pipe of outer dia 90mm and innter dia 75mm including 90 degree bends with coupler and rubber ring laid in trenches of size 90 mm suitable for cable protection of size 70 sqmm to 185 sqmm cable complete all as specified and directed.

1400

-

-

... More
M&L for dismantling and refixing of rolling shutter after servicing, greasing and overhauling of mannual rolling shutter any size complete including T&P charges, grease and other any parts required at site for functional of rolling shutter complete all as specified and directed by Engineer-in Charge.

2

-

-

... More
Supply and errect in true vertical in replacement of steel tubular swaged pole complete with MS Box plate 6 mm thick of size 300 x 300 mm finial taper plug, cap, bolt, nuts washers & screws as specified type 410-SP-31 (9 mtr long) Made out of ERW MS tubing confirming to IS-2713 Part II including painting with two coat of aluminium paint over a coat of red oxide primer.

5

-

-

... More
Supply and errect in true vertical in replacement of steel tubular swaged pole complete with MS Box plate 6 mm thick of size 300 x 300 mm finial taper plug, cap, bolt, nuts washers & screws as specified type 410-SP-55 (11 mtr long) Made out of ERW MS tubing confirming to IS-2713 Part II complete including painting with two coat of aluminium paint over a coat of red oxide primer.

10

-

-

... More
Supply, fixing and install in replacement of 7 mtr height mild steel octagonal pole top 70 mm, bottom 155 mm, surface finished: hot dip galvanised, 3 mm thickness with base plate 250mm x 250mm x12 mm and GI 64 micron, M19x600 EN 8 grade foundation bolt and 1 mtr decorative arm for light fittings complete including foundation drawing provided by OEM for foundation of pole. Note : Cost for RCC foundation as per drawing, Excavation, returning filling, 7mtr pole, foundation bolts and nutsetc shall be included in rate quoted.

10

-

-

... More
M&L for Demolition of PCC of any description above/below ground level exceeding 15cm complete all as specified and directed by Engr-in-Charge.

12

-

-

... More
M&L for PCC 1:4:8 type D2 using 40mm graded aggregate pole / struts foundation etc all as specified and directed.

10

-

-

... More
M&L for PCC 1:2:4 type C1 using 20mm graded aggregate for coping including necessary form work and fair finishing of exposed surface of concrete all as specified and directed.

2

-

-

... More
Supply and fixing in replacement of cross arms. Bracings, support channel, backpate hooks etc fabricated from structural steel, sections (MS Channel) of required size and shape including nuts, bolts,washers, welding, bending , cutting cold or hot, drilling holes for inserting bolts as indicated and directed including painting with one coat of red oxide primer and two coats of silver aluminium paint complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
Taking down written shut down for trimming of tree branches touching LT/HT over head line or near to the LT/HT over head line as per the direction of Engr- in-Charge complete including removing the tree branches from site complete all as specified and directed by Engr in Chatge. Note :(i) Span from one pole to next pole (30 to 50 RM) will be considered as a one Job (ii) Any damage caused due to contractor workmen will be rectified without any extra payment. (ii) T & P such as ladder, rope, cutter, Axes and other related material will be provided by the contractor without any extra cost.

20

-

-

... More
Material and Labour for replacement of jump connection by using ACSR conductor weasel, alkathine pipe, aluminium lugs, PG clamps, nuts, bolts etc. for complete 2 pole structure all as directed by Engineer-in-charge.

40

-

-

... More
Material and Labour for replacement of jump connection by using ACSR conductor weasel, alkathine pipe, aluminium lugs, PG clamps, nuts, bolts etc. for complete 4 pole structure all as directed by Engineer-in-charge.

28

-

-

... More
M & L in replacement of pole Earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the GI wire 4.0 mm dia, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 15 mm, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion”.

8

-

-

... More
Supply and fixing in replacement of RCC cable route marker/ indicator of size 0.30mtr x 0.15 mtr x 1.5 mtr complete including embossing "HT CABLE" and "LT CABLE", painting with one coat of primer and two coat oil paint as per colour coding providing by Engineer-in-Charge for exposed surface, excavation, PCC 1:2:4, etc included in this item rate complete all as specified and directed by Engineer-in-Charge.

50

-

-

... More
M & L in replacement Earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the GI strip 32 x 6mm, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 40 mm incl provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion”.

26

-

-

... More
M& L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine for LT underground cables suitable for 0.4 Mpa working pressure complete all as specified and directed.

40

-

-

... More
M&L for servicing GOD set by replacing stationary and moving contacts adjusting from ground level for smooth operation by replacing flexible copper strip, insulators, nuts, bolts, washer, GI pipe handle etc, all as directed by Engineer-in-charge. (Note- stationary moving contact, post insulator, GI pipe and handle shall be measured & paid separaletly).

20

-

-

... More
Supply only GOD handle with locking strip and insulation sleeve complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
Supply only GI pipe 25 mm dia "medium grade" 6 metre in length complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
Supply only stationary and moving contact set for GOD complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
Supply and fixing in replacement of post insulator 11 KV for GOD complete all as specified and directed by Engr-in-Charge.

14

-

-

... More
Supply and fixing in replacement of Disc insulator, polymer type single disc assembly for tension with tension clamps for conductors working pressure 11 KV grade complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
Supply and fixing in replacement of polymer pin insulator including one galvanised mild steel spindle two galvanised iron washres and one galvanised iron nut suitavble for 11 KV grade complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
Material and labour for cleaning/clearing of vegitation/ creepers on chain link fencing at the installations and disposing off as directed complete including painting of synthetic enamel silver paint on chain link fencing complete all as specified and directed by Engineer-in-Charge.

500

-

-

... More
Material and labour for cleaning/clearing of vegitation around the installations and disposing off as directed complete including spraying of grass killer chemical spray with the help of spray pump complete all as specified and directed by Engineer-in-Charge.

2000

-

-

... More
Supply, fixing and testing in replacement of air break gang operated device, triple pole mechanically operated outdoor type, mounted on and including 11 KV H.T. porcelain insulators 9 Nos and steel channel frame, GI operating rod, 25mm dia of suitaale length with operating mechanism working from ground level, vertically operated including locking arrangement for operating handle, suitable for current rating upto 200 Amp, 11000 Volts working pressure all as specified and directed by Engr-in -Charge.

10

-

-

... More
Supply and fix in replacement of dropout fuse unit explusion type for outdoor air break swirch (GOD) triple pole, mounted on and including insulators for 11000 Volts working pressure fixed to and including MS channel with nuts, bolts, washers etc. synthetic bounded fuse carrying tube complete with line tabs and suitable for current carrying capacity upto 200 Amps only all as specified and directed.

10

-

-

... More
Material and labour for stone aggregate 40mm graded spreading and leveling aroung 2 pole/ 4 pole structure where GOD installed including well ramming complete all as specified and directed by Engr-in-Charge.

50

-

-

... More
M&L in replacement of Lightening arresters station class complete with all fittings, station class, discharge capacity 65 kilo amps, suitable for 11000 Volts all as directed by Engineer-in-charge.

4

-

-

... More
M&L in replacement of Lightening arresters station class complete with all fittings, station class, discharge capacity 65 kilo amps, suitable for 33000 Volts all as directed by Engineer-in-charge.

2

-

-

... More
Supply, fixing and commissioning in replacement of ACB 4 pole, 415 volts ,50 KA,(Manual drawout type) of capacity 800 Amps ,microprocessor based with overload,Short Circuit,Earth fault protection with Push button for ON/OFF,ACB ON /OFF indicator,Safety shutters,charging handel ,Shunt trip coil etc complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
Material and labour for locating the fault on U/G HT cable 11 KV by using fault detector machine vehicle mounted including transport material and all accessories and carring out high pressure test all as specified and directed by Engr-in-Charge.

10

-

-

... More
Excavating in post holes each n'exc 0.5 Cum and getting out in in soft/ loose soil and returning filling in and ramming earth or broken boulders mixwed with earth around in layers n;exc 25cm complete all as specified and as directed by Engr-in-Charge.

6

-

-

... More
Supply and fixing steel work in tubular trusses including special shaped washers etc using ERW or induction butt welded tubes confirng to IS 1161-1979 grade St-240 complete all as specified and as directed by Engr-in-Charge.

140

-

-

... More
Supply and fixing rolled sections as in main and cross beams, Fe-410W purlinns etcfixed with angle cleats, or other connectig plates complete all as specified and as directed by Engr-in-Charge.

150

-

-

... More
Supply and fixing Pre-painted galvalume aluminium zinc coating GI based steel corrugated sheet 0.63 mm thick of Red colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws complete all as specified and as directed.

100

-

-

... More
M&L for painting of new or previously untreated surfaces including priming with redoxide, zinc chrome alongwith two coat of synthetic enamelled paint for surfaces of any description, over 10cm in width or girth, not otherwise described complete all as specified and directed.

10

-

-

... More
M&L for disconnecting HT/LT conections of defective Transformer upto 315 KVA of any type/capacity, taking out with the help of crane and transporting transformer to factory for repair & back after repairing to site including connecting, HT/LT connection earth connecting leads, testing and commissioning at site all as directed by Engineer-in-Charge. Note : (i) Rate quoted shall be inclusive of taking out and re-installing after repair of transformer with the help of crane, including transportation to workshop and back incluiding handling. (ii) Any damages during transportation or taking out/refixing is repaired or responsible by contractor on his own payment without any claim. (iii) Spares replaced will be measured and paid seperately under respecive items

2

-

-

... More
M&L for repair to transformer pole mounted/plinth mounted upto 315 KVA capacity to stop the leakage of transformer by lifiting core assembley with the help of chain pully block/crane, removing transformer oil, replacing cork sheet gasket 5mm thick, reassembling the transformer completely refilling transformer oil, connecting HT/LT connection. Note : (i) Spares required shall be measured and paid separately under relevant item. (ii) Any ty damages during transportation or taking out/refixing is repaired or responsible by contractor on his own payment without any claim. (iii) Item required for replaceme will be measured and paid seperately under respecive items

2

-

-

... More
Supply and fixing in replacement HV coil.

-

-

-

... More
(a) DPC Copper

60

-

-

... More
(b) SE Copper

60

-

-

... More
Supply and fixing in replacement LV Coil copper.

80

-

-

... More
Material and Labour required for replacement of unserviceable nuts/ bolts/ washer all as directed by Engineer-in-charge

12

-

-

... More
Material and labour for removing old silica gel, cleaning breather and filling new silica gel complete all as directed.

4

-

-

... More
Material and labour for replacement breather assembley with silica gel suitable for upto 500KVA transformer.

10

-

-

... More
Supply and fixing in replacement porcelain bushing LV side 433 Volt of required/adequate size and shape complete all as specified and directed by Engr-in Charge.

12

-

-

... More
Supply and fixing in replacement of HT bushing porcelain, vitreous brown/green 11000 Volts grade suitable for any type of transformer all as directed by Engineer-in-Charge.

10

-

-

... More
Supply and fixing in replacement HV rod brass, 12mm dia with brass nut 2 Nos and rubber bush 300mm long all as directed by Engineer-in-Charge.

12

-

-

... More
Supply and fixing in replacement LV rod brass 15mm dia, 300mm long with rubber bushing and brass nuts 2 Nos all as directed by Engineer-in-Charge.

10

-

-

... More
Supply and fixing in replacement LV rod brass 20mm dia 300mm long with rubber bushing and brass nuts 2 Nos all as directed by Engineer-in-Charge.

8

-

-

... More
M&L for replacement drain valve 25 mm dia

1

-

-

... More
M&L for replacement drain valve 40 mm dia

1

-

-

... More
M&L for replacement drain valve 50 mm dia

1

-

-

... More
M&L for Servicing /Repair to HT Pannel of having vaccum circuit breaker 11 KV rating of capacity current rating upto 400 Amps to 600 Amps of any make & type, servicing of VCB by cleaning contacts moving parts removing dust particles from spout gear mechanisum and moving parts repairs to motor, change spring mechanisum tightening of nuts & bolts of entire trolly components all as directed inserting in trolly, testing, commissioning putting on the supply on load complete all as specified and directed and scope of work incudes following :- (a) Inspection and cleaning breaker mechnisum assembly & check proper operation and repair work.. (b) Servicing for proper operation of door interlock, interlocking plates and shutter assembly inside of panel.permissible limits, readjust as recommended. (c) Check the mechanical on/off function, electrical & mechanical operation & damaged part of VCB. (d) Re-greasing with jelly of breaker mechanisum, adjustment of various mechanisum, setting as required, checking contact tightness, contact erosion pins, manually vaccume check of VCB. (e) Racking-Rack out operation in test and service position of VCB trolly . Megger Test (IR Value- 1KV/2.5KV) E-RYB, RY-YB, BR-R'R, Y'Y, B'B. (g) CRM Test(Contact Resistance) of Vacume Interupter RYB in On condition out side of panel. (h) Time test of contact pole by test kit (in mili seconds).

4

-

-

... More
Item No 69 Contd/.. (j) Function of closing coil, trip coil, spring charging motor, auxilliary contact, limit switch etc. (k) Checking and lubrication of various interlocks. (l) Removing all the moisture content inside the VCB panel all as specified by OEM. (m) After servicing test report shall be furnished in standard format approved by E-in-C. Note :- (i) The cost of minor parts ie nuts ,bolts,spring washers,dust cover ring of isolarors contacts,clips pins for release prop,Y phase shrouded over side stop pin,and all other minor parts ie packing essentially required to make the panel dust proof shall be deemed to be included in the rate quoted by the contractor . (ii) The servicing will be carried as per norms of OEM. (iii) The periodicity for carrying out the preventive maintenance as per the scope included in the above item shall be Three Months. Unit of the payment for carrying out each of the periodic check and maintenance at interval of Three Months shall be consider as each.

-

-

-

... More
Supply and fixing in replacement of digital multifunction meter 4" x 4" size suitable for panel board mounting, 11 KV Make : L&T Cat Part No WDM303FDWA1/ Conzerv DM 3251.

2

-

-

... More
Supply and fixing in replacement of bus bar stud support insulator 11 KV epoxy type suitable for VCB Panel.

6

-

-

... More
S&F and connect in replacement current transformer, resin cast body indoor type of current ratio 100 / 50 / 5 A, 15 VA, Class IL,17.2/20/60 KVP HSV 7.2KV, 50 Hz.

1

-

-

... More
Supply and fixing in replacement of testing of current transformer and calibration of 33 KV HT control relay for overcurrent and earth fault protection by primary and secondary ejections method and submitting test report duly signed by Engineer in Charge.

1

-

-

... More
Supply and fixing in replacement of for testing of current transformer and calibration of 11 KV HT control relay for overcurrent and earth fault protection by primary and secondary ejections method and submitting test report duly signed by Engineer in Charge.

1

-

-

... More
M&L for servicing of 33 KV VCB of any capacity as and when ordered by Engr-in-Charge, including servicing, adjusting & fault finding & rectifying the fault by skilled Engr & testing the unit complete & submitting test report all as specified and as directed:- (a) Inspection and cleaning breaker mechanism assembly & check proper operation and repair work.. (b) Servicing & overhauling for proper operation of door interlock, interlocking plates and shutter assembly inside of panel.permissible limits, re-adjust as recommended. (c) Check the mechanical on/off function, electrical & mechanical operation & damaged part of VCB. (d) Re-greasing with jelly of breaker mechanisum, adjustment of various mechanisum, setting as required, checking contact tightness, contact erosion pins, manually vaccume check of VCB. (e) Racking-Rack out operation in test and service position of VCB trolly (f) Megger Test (IR Value- 1KV/2.5KV) E-RYB, RY-YB, BR-R'R, Y'Y, B'B. (g) CRM Test (Contact Resistance) of Vacume Interupter RYB in On condition out side of panel. (h) Time test of contact pole by test kit (in mili seconds). Function of closing coil, trip coil, spring charging motor, auxilliary contact, limit switch etc. (j) Checking and lubrication of various interlocks. (k) Removing all the moisture content inside the VCB panel all as specified by OEM. (l) After servicing test report shall be furnished in standard format approved by Engr-in-Charge.

1

-

-

... More
M&L for machine pressed precast interlocking tile any size and shape of 60 mm thickness M-35 grade confirming to IS: 15658-2006 with grey cement and pigment and vibrated with mechanical vibrator , with 30mm thick crushed sand for cushioning all as directed.

770

-

-

... More
M&L for machine pressed precast interlocking paver block any size and shape of 80 mm thickness M-40 grade confirming to IS: 15658-2006 with grey cement and pigment and vibrated with mechanical vibrator , with 30mm thick crushed sand for cushioning all as directed.

800

-

-

... More
Supply and fixing in replacement of angle iron post for chain link fencing, cross arms. Bracings, support channel, backpate hooks etc fabricated from structural steel, sections (MS Channel) of required size and shape including nuts, bolts,washers, welding, bending, cutting cold or hot, drilling holes for inserting bolts as indicated and directed including painting with one coat of red oxide primer and two coats of silver aluminium paint complete all as specified and directed by Engr-in-Charge.

5

-

-

... More
Supply only chain link fencing MS galvanised, any size or type complete all as specifed and directed.

500

-

-

... More
Fixing only in replacement chain link fencing icluding line wires any mesh size and type of standard rails straining bolts etc including provision of binding wire complete all as specified and directed.

1000

-

-

... More
M&L for scrapping the existing deterioted old alumininum paint by iron brushing and painting of steel tubular poles of (11.0 mtr length- Two pole structure) with one coat of metal primer and two coat of aluminium paint over exposed portion of pole above PCC coping including cross arms, angles, nut, bolts, clamps and S&F new radium sticker Radium paint / sticker of different colour 80 cm above coping of pole, i.e. alernatively with sky blue / red & white radium sticker (10 cm - 04 sky blue / red strip and 10 cm - 04 white strip) complete circumference of any type any shape pole and cement base paint on coping portion, marking of pole nos with radium yello / black paint /steekar in round shape 15 cm dia with letter writing 5 cm height 5 mm width etc. complete all as specified and directed at site.complete all as specified and directed at site by Engineer-in-Charge

8

-

-

... More
M&L for scrapping the existing deterioted old alumininum paint by iron brushing and painting of steel tubular poles of (11.0 mtr length- four pole structure) with one coat of metal primer and two coat of aluminium paint over exposed portion of pole above PCC coping including cross arms, angles, nut, bolts, clamps and S&F new radium sticker Radium paint / sticker of different colour 80 cm above coping of pole, i.e. alernatively with sky blue / red & white radium sticker (10 cm - 04 sky blue / red strip and 10 cm - 04 white strip) complete circumference of any type any shape pole and cement base paint on coping portion, marking of pole nos with radium yello / black paint /steekar in round shape 15 cm dia with letter writing 5 cm height 5 mm width etc. complete all as specified and directed at site.complete all as specified and directed at site by Engineer-in-Charge.

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.