Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date20 Dec 2024
Closing Soon30 Dec 2024
Tender Amount₹ 32,00,000
Costs
EMD
₹ 64,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_687302_2Tender No
8249/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil
455
-
-
... More
M&L for cutting of vegetation, grass shrubs grown above ground level using mechanical/manually and removing the same from the site complete all as specified and directed.
455
-
-
... More
Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level)and removing the rubbish to a distance not exceeding 50 m from starting point complete all as specified and as directed by Engineer-In-Charge.
2.93
-
-
... More
M&L Cement concrete type D2 1:4:8 (40mm aggregate) in foundations, filling and mass concrete
23.62
-
-
... More
M&L Hardcore (Broken stone & boulders) of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
29.75
-
-
... More
M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering
21.5
-
-
... More
M&L 75mm Cement concrete type B-1, 1:2:4 (20mm graded aggregate) Finishing cement concrete surface even and smooth
215
-
-
... More
M&L Cement concrete type B0 1:2:4 (12.5mm graded aggregate) in surface channels and drains laid chamfered inside drains inc coping
5.3
-
-
... More
M&L Cement concrete type B-2, 1:2:4 (40mm graded aggregate) Cement concrete in foundations, filling and mass concrete
8.1
-
-
... More
M&L rendering 15 mm thick on other than fair faces of brick work or concrete surfaces with CM (1:4)finished even and smooth without using extra cement.
340.92
-
-
... More
M&L for preparation of newly plastered surface of wall and applying 2 coat of cement based paint on one coat of alkali resistant primer complete.
110.9
-
-
... More
S&F Precast cement concrete load class for HCV perforated and single layer of 10 mm dia steel bar 100mm C/C cover dimensions 500x550x75 mm or required size Make : KK, Universal, Hindustan and equivelent all as specified and directed by Engr in Charge.
121.1
-
-
... More
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
499.63
-
-
... More
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out mud complete all as specified and directed
28
-
-
... More
M & L for reinforced cement concrete pipes, class NP-2, laid and jointed complete with collars, bore of pipe 450mm.Complete all as specified and directed by Engineer-in-charge. Make : Hindustan / Universal or equvilant confirming to IS.
18
-
-
... More
M & L for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate, Concrete bed to 450mm dia NP2 drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested Complete all as specified and directed by Engineer-in-charge.
18
-
-
... More
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick with soils.Complete all as specified and directed by Engineer-in-charge.
19.39
-
-
... More
Removing surplus excavated material (Soils) to distance of exc. 250 m bu n. exc. 500 m and depositing where directed at a level n. exc. 1.5 m above the starting point. complete all as specified and as directed by Engineer-In-Charge
8.59
-
-
... More
Demolition and breaking up drain pipes (Salt glazed ware , AC or RCC or PVC Pipes) of any dia including all fittings any size all as specified & as directed by Engr-in-Charge.
28
-
-
... More
S& F PVC (SWR) pipes 160mm dia single, socketed in any length ,with rubber ring joints fixed to walls with MS clamps.
82
-
-
... More
S&F PVC (SWR) bends 160mm dia
40
-
-
... More
S&F PVC (SWR) shoe 160mm dia
18
-
-
... More
Removing of building materials and debris of any type, rate including i.e loading unloading and staking and spreading etc outside of MD land with own arrangement by contractor (01 tonne considered as 1 load) all as specified and directed by Engineer in charge
50
-
-
... More
Taking down cement plaster on brick or stone wall any description including raking out joints, hacking for key, scrubbing down with water etc.compete all as specified as directed by Engineer -in -charge.
90.9
-
-
... More
M&L for 15mm thick rendering on brick/concrete surfaces on broken edges of chajjas, facia, slab, roof projectioon and any other brick/concrete surface in patch work in CM 1:4 and finishing fair and even without using extra cement with using 2% Integral water proofing compound by wt of cement (Note: Water proofing compound will be measured and paid separately under relevant item) Note: The rate quoted shall be deemed to include for work up to four storey building & height upto 15.00m including all safety measures, scaffoldings etc., required for carrying out the work and nothing extra on this account shall be admissible.
90.9
-
-
... More
Supply only integral water proofing compound
16.7
-
-
... More
M&L for applying two coat of damp proof water proofing paint as per manufactures intsruction over roofs, chajjas after plaster repair of Make: Asian Paints/ Berger all as approved and specified.
NOTE : The contractor should ensure that proper site survey using levels to ascertain natural slope of ground should be conducted before commencement of work. No extra payment may be claimed in this regard.
100
-
-
... More
Dismantling of floor, hearth or wall tiling including cement mortar bedding, removing servicable tiles to store and rubbish off the premises compete all as specified and as directed.
31.23
-
-
... More
M & L 25mm thick Cement concrete 1:2:4 type B0 ( using 12.5mm graded stone aggregate as in sub base , floors , finishes etc ., complete all as specified and as directed.
9.17
-
-
... More
M & L Screed bed or bedding layers of mortar 15mm thick for laying floor finishes in CM1:6 complete all as specified and as directed.
9.17
-
-
... More
M & L rendering 10mm thick as in backing coat in CM 1:4 complete all as specified and as directed.
31.23
-
-
... More
M & L Glazed ceramic tiles in vertical surfaces 450mm x 300mm x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement complete all as specified and as directed.
31.23
-
-
... More
M & L for coloured non skid ceramic tiles exc .06 sqm but n exc .11 Sqm as in floors set and pointed in white or coloured cement to match complete all as specified and as directed.
9.17
-
-
... More
S & F in repairs vitreous china wash down water closet pedestal pattern (EWC) white excluding flushing cistern & Incl white seat cover of same make closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device and flush pipe.Complete all as specified and directed by Engineer-in-charge.
1
-
-
... More
S & F in repairs vitreous china wash down water closet pedestal pattern (EWC) white excluding flushing cistern & Incl white seat cover of same make closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device and flush pipe.Complete all as specified and directed by Engineer-in-charge.
1
-
-
... More
S&F in repair viterous chaina half stall urinal flat back white, with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waster pipe) including providing and fixing plugh bedding Urinal against wall in CM 1:2 securing Urinal to plug with and including 60 mm long brass screw pointing around urinal back in cement etc complete all as specified and as directed.
3
-
-
... More
S & F in repairs Bottle trap of 40mm dia of discharge pipe of PTMT having minimum water seal of 25mm .(Minimum weight 40mm-270 gms) complete all as specified and as directed.
3
-
-
... More
S&F in repairs 10 litres capacity PVC Valveless symphonic action type flushing cistern high / low level white complete with inlet , ball valve float and handle including brackets and telescopic down pipes and jointing with WC complete complete all as specified and as directed by Engineer-In-Charge. Make Parryware (Slim line)/Hindware (1st Quality)/Commander (waterbird)
1
-
-
... More
S&F in repairs PVC connection 15mm size with PTMT nuts of length 450 fixed complete all as specified and directed.
6
-
-
... More
S&F in Repair Cast copper alloy CP angle valve type stop cock with flange suitable for 15mm bore pipe screwed at both ends or high pressure with Capstan head confirming to Prayag /Seiko/ Parko Complete all as specified and as directed by Engineer-In-Charge.
6
-
-
... More
S&F in repairs 15mm bore pillar tap fancy type cast copper alloy chromium plated screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screw shanks screwed for iron pipe or union complete all as specified and as directed.
2
-
-
... More
S & F in repairs 600x450 mm bevelled edge looking mirror of selected quality glass ,mounted on 6mm thick , Acbuilding board or commercial plywood and fixed to wooden plugs with chromium plated brass screws & cup washers etc complete all as spicified & directed.
2
-
-
... More
S & F in repairs sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated brackets guard and railing 60cm long complete all as specified and as directed.
2
-
-
... More
S&F in repairs bib taps two way,15mm bore cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and. complete all as specified and as directed.
1
-
-
... More
S&F in Repair Brass chromium plated tubular towel rail 20mm dia 60cm long with and including flanges complete all as specified and as directed by Engineer-In-Charge
2
-
-
... More
S & F in repairs soap dish stainless steel as approved by GE complete all as specified and as directed by Engineer-In-Charge.
2
-
-
... More
Taking up or down steel tubing and connections 15 mm bore complete all as specified and directed.
7.6
-
-
... More
Taking up or down steel tubing and connections 20 mm bore complete all as specified and directed.
5
-
-
... More
Supplying and laying of CPVC 20 mm outer dia pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
7.6
-
-
... More
Supplying and laying of CPVC 25 mm outer dia pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
5
-
-
... More
S&F in repair PVC (SWR) 110 mm dia pipes single socketed in any length with rubber ring joints laid in trenches/floor or fixed to walls including digging and making good as existing complete all as specified and as directed.
10
-
-
... More
S&F in repair 110mm dia PVC (SWR) bend any radiu complete all as specified and as directed.
2
-
-
... More
S & F in repair PVC (SWR) floor trap of 75 mm outlet plain with grating including jointing with solvent cementComplete all as specified and as directed.
3
-
-
... More
S & F 110mm PVC (SWR) Vent Cowl complete all as specified and as directed..
1
-
-
... More
S&F high density polyethylene pipes (HDPE) 40mm Bore of pressure rating 6kg/cm2 fixed complete to walls, ceiling or in floors etc complete all as specified and as directed.
8.5
-
-
... More
M&L Brick work with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1 : 6 as in Manholes/ similar work including pointing flush the external face of the brick work as the work proceeds all as specified and directed by Engr-in-Charge
5.77
-
-
... More
M & L for demolition of reinforced cemetn concrete at Roofs, floors (other than ground
floors), beams, staircases, landing,chajjas and similar suspended work complete all as specified and as directed.
0.09
-
-
... More
M&L for reinfirced cement concrete (nominal Mix) in type B1 1:2:4 (20 mm graded aggregate ) for Slabs supported on walls,beams and columns in floors,roofs, landings, balconies, canopies, deck slabs and in shelves. Complete all as specified and directed by Engineer-in-charge
0.09
-
-
... More
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick Complete all as specified and as directed by Engineer-In-Charge.
0.75
-
-
... More
S & F for deformed or twisted bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia.Complete all as specified and directed by Engineer-in-charge.
8.88
-
-
... More
All as per item No.63 above but 6mm to 8mm dia bars.
13.48
-
-
... More
Taking down door/window/ventilator with frame but and shutter (without taking off shutters from the frame) and remove from site n. exc 1.5 sqm each complete all as specified.
5
-
-
... More
S & F Pressed steel frame of 105mm x60mm of thickness 1.25mm for with one or more 30mm rebates including necessary supply and fixing lungs, locks, strike plate including fixing of hinges etc also including flat iron hold fast threshold plate and filling with PCC 1:3:6 inside MS frame all as specified and as directed.
4.75
-
-
... More
Forming jambs in Cement concrete 1:4 to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complet all as specified and as Directed .
2.07
-
-
... More
M&L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars ,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, over and including15 mm cement screed bed in CM 1:6 laid and jointed in grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and as directed.
3.75
-
-
... More
S&F aluminium powder coated frame for louvers section of size 75x40x1.6mm including 4mm thick glass in louvors of 100 mm width with glazing cleat and revolving arrangement of standard section of aluminium including rubber packing, aluminium beading or gasket for for aluminium sections for fixing glass sheet and necessary fittings complete screws plugs, handle, tower bolt, stay hooks including fixed Aluminium wire cloth etc all as specified and directed by Engineer in Charge.
1.62
-
-
... More
S & F for 35mm thick second classhard wood, factory made Plain, framed,panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats (Shutters shall be brought at site without primer and got approved by Engr-in-Charge/ GE.)
1.47
-
-
... More
S&F Supply and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame., complete as specified by the manufacturer and as per directions of Engineer-in-charge. (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life)
4.85
-
-
... More
S&F Supply and fixing 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table 3 of IS: 14856 complete all as specified by the manufacturer and as per directions of Engineer- in-charge (Make-Rajashri/Sintex/ Accura)
1.37
-
-
... More
S & F 100 mm MS butt hinges medium weight cold rolled mild steel compete all as specified as directed by Engineer -in -charge
6
-
-
... More
S & F 150 mm aluminium anodised barrel tower bolts of extruded section, ISI marked compete all as specified as directed by Engineer -in -charge
4
-
-
... More
S & F 150 mm extruded aluminium alloy handles , fabricated type, anodised, ISI marked compete all as specified as directed by Engineer -in -charge
4
-
-
... More
S & F 300 mm long and Mild steel Chromium plated sliding door bolts, plate type, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed compete all as specified as directed by Engineer -in -charge
1
-
-
... More
Taking down of existing bird proofing net with accessories complete.
1465
-
-
... More
S & F as in Repairs anti bird net, Square mesh size 20mm x 20mm black/white of any colour HPDE knotted net, thickness of the net 1.00mm , weatherproof , Uv stablized and chemically inert / breaking strenth of 23.08kg per yarn , having a melting point of 260 centigrade fixed with border rope of dia 4mm , UV stabilized border rope joint with the net by machine inter locking process using three ewinces of the same as that of tied to 12mm dia hooks (made to shaper) or welded to steel structure and 12mm dia anchor fastner bolt fixed in RCC structure as applicable as suitable intervals complete up to height 16 mtr work shall be executed. all as specified and as directed.Note:- Taking down the existing hangar lights carefully and refixing the same after completion of item No 1, there shall be no extra payment on this account, rate shall be deemed in quoted item above .
1465
-
-
... More
Dismantling of Asbestos cement (corrugated,semicorrugated, etc.) sheets in roof coverings complete all as Specified and as directed .
91
-
-
... More
Supply & Fix Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick multirib TM profile of any colour having tensile of 550 Mpa yeald strenth as in roof cobering/cladding to wall fixed with self tapping screws of manglore pattern of any approved pattern compltete all as specified and as directed.
91
-
-
... More
All as per item no 80 above but as in ridge portion
8.1
-
-
... More
Dismantling framed Trusses span Exc 10 mtr but n exc 15 Mtr complete all as specifed and as directed.
1
-
-
... More
Erection and fixing only Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete alll as specified and as directed.
1264.68
-
-
... More
S & F Expanded metal Sheet/Mesh 9.5mm x 28.5mm, 1.6mm thick of Size for ventilators complete all as specified and as directed.
37.37
-
-
... More
Rendering 10 mm thick in cement mortar 1:6 on brick work or concrete surfacces and stone masonary and finishing the surface even and smooth without using extra cement complete all as specified and directed.
22.28
-
-
... More
M & L prepration of New plaster surfaces applying two coat of Oil bound distemper using roller, brushes including in patches over a coat of primer coat of 1.50 mm thick in two layers putty and minimum 6 hr interval between the coats on surfaces complete of wall. all as specified and as directed by Engineer in charge
22.28
-
-
... More
Complete Removal of existing treatment on old surfaces of wall/ ceiling and make the surface smooth by rubbing/filling the holes with cement based wall care putty and applying two coat of cement base paint white or tinted including cornices etc.complete all as specified and as directed by Engineer in charge.
Note : Curing is essential before & after application of cement base paint. Contractor is make his proper arrangement of work scaretted in all the buildings.
34.52
-
-
... More
Complete Removal of existing treatment by scrapping down smoke soot, moulds, moss and efflorescent salts and greasy spots, plastic emulsion paint, synthetic enamal paint and removing nails and fill the holes with putty etc and applying two coat of Oil bound distemper using roller, brushes including in patches over a coat of primer coat of 1.50 mm thick in two layers putty and minimum 6 hr interval between the coats on surfaces complete of wall. all as specified and as directed by Engineer in charge
67.74
-
-
... More
M & L for Prepartion of new steel surfaces of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of zinc choromate primer complete all as specified and as directed
6.91
-
-
... More
M & L for preparation of Old previously untreated steel surface and applying two coats of synthetic enamal paint over a coat of zinc primer coplete all as specified and as directed.
42.79
-
-
... More
M&L for earthing in repair including taking out GI plate with pipes earthing lead fasteners etc and earthing complete with galvanised steel earth plate electrode 600x600x6mm thick,burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the pl;ate not less than 1.5 Mtr below normal ground level,connected to galvanised iron strip 32x6 mm as earth lead by means of bolts,nuts ,washer and check nut of galvanized steel, protected by and including GI pipe 50 mm bore (light grade) and connected to main switch / MCB DBs box point / LP test point as directed and including cement concret pit in 1:2:4 type B1 using 12.5mm graded aggregate, with cast iron miled steel frame embedded in the concrete enclouser fineshed flushed & CI cover 10 mm thick of size (300mmx300mm CI) having locking arrengment hinged to CI frame all as shown under electrical plate of SSR Pt - I 2009 and as directed including painting the external surface of chamber & cover with enamel paint in diffrent colour as directed and writing earth results & date of test carried out with white paint on black painted background, wiremesh funnel 20 mm bore GI pipe medium grade for watering adequate quantity of charcol and common salt in alternate layer of 15cm 3ft x 3ft thick all around the electrode including necessery excavation & earth work in any type of soil complete testing on completion all as directed. Note:- i) Filling the pit with black cottan soil brought at site. ii) The excavated soil will be removed & paid separtely.(h) Earth strip GI of size 32x6mm from earth pit to testing point up to 7.5 mtr included in the quoted rates
15
-
-
... More
Supply, install , testing and commissioning maintence free earthing comprising of high tensile pure copper (99.99%) earth electrode 17.2 mm dia and 3 mtr long , intallation of earthing electrode boring 165mm X 4 mtr long with ground enhancing compound and back-fill compound (not less than 50 Kg ) strictly be a carbon based conductive concreate type which has resistively of less than 0.12 ohm mtr as per clause 14.5 D of IEEE:80 Standard back-fill compound should be electronically conductive (like in metals) and should not depend on moisture for condition.Commissioning, testing & report submission ( To achieve value below 1 ohm in hard rock , mountaing ) etc.Make- Yes Earthing solution or equvalent.
6
-
-
... More
Note :-Compound shall be suplied in sealed bags. The earth electrode should finally be housed in heavy duty chamber with cover of suitable size as per OEM recommendation . Ground Enhancing compound and Back-fill compound should be enviroment freindly, , ionic property to create ions for easy conduction , the compound shoul expand so much to remove entrapped air ( bad conductor electricity ) and to creat strong conduction between electrode and soil , the compound should have a property to assist in absorbing humidity from the neightboringsoil to keep the earth pit moisture . The product should be tested and certified at CPRI for long term stability of earth pits. The testing has to be carried out for minimum duration of two years continously. (f) Testing on completion & achiving resistance less than 01 ohm & submitting report to Engineer-in Charge duly signed by user after seccessfull completion of earthing whytime after euevution up to end of defect liabuility perioed. (g) If resistance value is found more than 1 ohm, contractor has to do additional earthing with in 07 days without any extra cost (h) Earth strip copper of size 32x6mm from earth pit to testing point up to 7.5 mtr included in the quoted rates Make:- Yes Earthing ,SGI Engineers PVT Ltd, U protect.
-
-
-
... More
Supply & fix earth ontinuty conductor or main earthing lead of 32X6 mm galvanised iron strip (roof conductor or down conductor ) above ground level fixed to wall/ roof duly insulated on batten or fixed on new porcelain insulators with clamping device or recessed or chases or burried in groung/ floor or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc as required all as directed by Engg. in charge. Note :- i) the distance between porcelain insulator will not be included with cost of T & P and labour required to work on roof top at lateral faces of existing hangers upto height of 25 mtrs.
80
-
-
... More
All as per item no-3 but 20 x 3 mm copper strip.
80
-
-
... More
All as per item no-3 but GI wire 4 mm dia GI wire.
100
-
-
... More
M&L for brazing of existing copper earthing including all brazing materials as required at site complete all as specified and as directed.( Note :- The rate of T&P , Gas cylinder , weilding machine etc are included in the quoted rates quoted by the contractor
25
-
-
... More
Supply and fixing PVC / Porcelain insulator for GI/Aluminium strip supporter adequate to accomadate strip of 32 mm with fasteners for fixing on wall / hanger CGI Sgeet / floor etc on existing strip etc )complete all as specified and directed.
280
-
-
... More
S&F stop valve, cast MS alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for fixing with 15 mm iron pipe or for union complete all as specified and directed.
15
-
-
... More
Taking up or down old rusted water tubing and connections fixed to wall floor, celing for bore of 15 mm dia , complete all as specified and as directed by Engineer-In-Charge.
100
-
-
... More
Supply & Fix GI water tubing medium grade with all fitttings and fixed to wall, floor,in trenches, ceiling for bore of 15 mm diameter, complete all as specified and as directed by Engineer-In-Charge.
50
-
-
... More
Fixing only old serviceable water tubing medium grade received from item No 5 here in before and connected with new fittings of medium grade as required including cleaning, cutting, threading and fixed to wall, floor, ceiling for bore of 15 mm diameter , complete all as specified and as directed by Engineer-In-Charge.
50
-
-
... More
Taking down old serviceable HT/LT cable from trench/wall/roof and re-laying the same after drainage work in existing place including all excavation and eartth work and elctrical connection as reqd at site all as directed.
100
-
-
... More
M & L for Straight through joints (heat shrink type) for LT underground cable including joint kits and labour complete for making joints suitable for aluminium conductor cables 3 1/2 core 25 to 70 Sqmm.
4
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%