Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Security and Emergency Services
Eprocure
Opening Date19 Dec 2024
Closing Date9 Jan 2025
Tender Amount₹ 40,00,000
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_683560_2Bid Award Id
ViewTender No
GERD/PSN/TOKEN/51 OF 2024-2025Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
200 KVA DG Set at Pigio, PGM Bldg in ARDE andData Center in HEMRL
3
-
-
... More
250 KVA DG Set at B Power House , CADAS in ARDE and MIXER House bldg and HD 1.1 bldg in HEMRL.
4
-
-
... More
380 KVA DG Set at igniter complex HEMRL.
1
-
-
... More
625 KVA DG Set at B Power House
1
-
-
... More
Material and labour for battery cable of 70 sqmm, PVC insulated, multi stranded, copper conductor single core cable with necessary copper lugs and connections complete all as specified and directed.
10
-
-
... More
Supply and top up of Premix Ethylene Glycol coolant for Engine Radiator complete all as specified and directed.
220
-
-
... More
Material and labour for battery terminals made out of brass with nut bolts & washers and necessary brazing to cable complete all as specified and directed.
10
-
-
... More
Supply and fix in repairs flexible braided high pressure hydraulic hose including both ends chromium plated end connections check nuts and washers for the following :-
For by pass filter / super by pass filter.
2
-
-
... More
For fuel supply.
2
-
-
... More
For fuel return.
2
-
-
... More
For pressure gauge.
2
-
-
... More
For water vent.
2
-
-
... More
Supply only by pass filter element with 'O' ring suitable for DG Sets of following capacities :-
62.5 KVA to 125 KVA
12
-
-
... More
200 KVA to 625 KVA
9
-
-
... More
Supply only fuel filter primary and secondary with 'O' ring for DG Sets of following capacities :-
62.5 to 125 KVA
12
-
-
... More
200 KVA to 625 KVA
9
-
-
... More
Supply only oil filter with 'O' ring for DG Sets of following capacities :-
62.5 to 100 KVA
6
-
-
... More
125 to 200 KVA
9
-
-
... More
250 KVA to 315 KVA
6
-
-
... More
625 KVA DG Set
2
-
-
... More
Supply and fix rubber hose set with clamps for DG Set radiator including taking down existing unserviceable hose set complete for the following capacities of DG Sets :-
62.5 to 100 KVA
3
-
-
... More
125 KVA to 200 KVA DG Set
3
-
-
... More
250KVA to 380 KVA DG Set
2
-
-
... More
625 KVA DG Set
1
-
-
... More
Supply and fix in repair water temperature gauge dial of dia 50mm complete all as specified and directed.
3
-
-
... More
Supply and fix in repair oil pressure gauge dial of dia 50mm complete all as specified and directed.
3
-
-
... More
Supply and fix in repair oil temperature gauge dial of dia 50mm complete all as specified and directed.
2
-
-
... More
Supply and fix in repairs fan belts for following DG Sets, complete all as specified and directed.
Make : Fenner / Dunlop or as per existing make
62.5 KVA to 100 KVA DG Set
2
-
-
... More
125 KVA to 200 KVA DG Set
3
-
-
... More
250 KVA to 625 KVA DG Set
4
-
-
... More
Supply and fix in repair ignition switch with key for DG set complete all as specified and directed.
2
-
-
... More
Supply and fix in repair LED TYPE indicating lamps for DG Set control panel/AMF panel complete all as specified and directed.
10
-
-
... More
Supply and fix in repair digital voltmeter 0-600 Volts complete all as specified and directed.
3
-
-
... More
Supply and fix in repair digital ammeter CT operated 0-200/400 amps complete all as specified and directed.
2
-
-
... More
Supply and fix in repair digital frequency meter 40 to 55 Hz complete all as specified and directed.
2
-
-
... More
Material and labour for repair of AC alternator of 125 to 250KVA DG Set with replacement of burnt copper wiring of the same gauge and refixing the same after duly repair including testing and calibration complete all as specified and directed.
1
-
-
... More
Material and labour for repair of AC alternator of 62.5 KVA to 100 KVA DG Set, with replacement of burn copper wiring of the same gauge and refixing the same after duly repair including testing and calibration complete all as specified and directed.
1
-
-
... More
Material and labour for cleaning of raditor,external cleaning by vaccum cleaner, petrol washing and taking out the carbon deposits from cooling fins and internal cleaning by using restor plus liquid and inhibitor corrosion of 62.5 KVA to 100 KVA DG Set complete all as specified and directed by Engineer-in-charge.
2
-
-
... More
Material and labour for cleaning of raditor,external cleaning by vaccum cleaner, petrol washing and taking out the carbon deposits from cooling fins and internal cleaning by using restor plus liquid and inhibitor corrosion of 125 KVA to 250 KVA DG Set complete all as specified and directed by Engineer-in-charge.
2
-
-
... More
Material and labour for cleaning of raditor,external cleaning by vaccum cleaner, petrol washing and taking out the carbon deposits from cooling fins and internal cleaning by using restor plus liquid and inhibitor corrosion of 625 KVA DG Set complete all as specified and directed by Engineer-in-charge.
1
-
-
... More
Supply and fix in reapir heavy duty maintenance free batteries of capacity 12 Volts, 180 AH suitable for AMF DG set including connecting brass and copper lugs with terminals. Make : Exide or equivalent standard Amron, Tata Green, Furukawa with replacement warranty 18 Months.
2
-
-
... More
Supply and fix in reapir heavy duty maintenance free batteries of capacity 12 Volts, 150 AH suitable for AMF DG set including connecting brass and copper lugs with terminals. Make : Exide or equivalent standard Amron, Tata Green, Furukawa with replacement warranty 18 Months.
3
-
-
... More
Supply only distilled water for batteries complete all as specified and directed.
120
-
-
... More
Supply and fix in repairs 4 pole power contactor , coil voltage 230/415 Volts for following capacity :-
(a ) 160 Amps to 200 Amps
2
-
-
... More
(b) 225 Amps to 255 Amps
2
-
-
... More
(c) 320 Amps to 400 Amps
2
-
-
... More
Repair / modification of control wiring of AMF panel using AMF relay for smooth functioning of DG Set 125 to 250 KVA including renewal of wornout spare parts complete all as specified and as directed.
NOTE:-
(i) Spares to be renewed will be measured and paid separately as "Supply only". The rate quoted is deemed to include for minor spares. (ii) Labour charges for dismantling / taking down and replacement / refixing new parts as and when required is deemed to be included in unit rate quoted. (iii) Unit rate quoted shall also include for painting of AMF panel including welding work and replacement of hinges, nut, bolts as required.
4
-
-
... More
Supply only spare parts to incorporate in Items no 50 above :-
a) Auto main selector switch
3
-
-
... More
b) AMF relay 12/24 volts
2
-
-
... More
c) Magnetic relay 12/24 volts DC
2
-
-
... More
d) Push button with element
4
-
-
... More
e) Single phase preventor
4
-
-
... More
f) Electronic battery charger 12/24 volts with AC/DC conversion
3
-
-
... More
g) Control fuse with base
4
-
-
... More
h) Add on block with No/NC
2
-
-
... More
j) Selector switch for ON / OFF of DG Set
2
-
-
... More
k) DC mode selector switch
2
-
-
... More
Supply and fill Engine oil 15 W of 40 grade or as required grade complete all as specified and directed.
550
-
-
... More
Supply, fixing, testing and commissioning of microprocessor of DG Set controller along with electronic circuits and controls DG Set of capacity 100 KVA to 125 KVA complete all as specified and directed.
1
-
-
... More
Material and labour for repair of self starter assembly 12 volts /24 volts suitable for 125 to 250KVA DG Set, including replacement of burn copper wiring of the same gauge and refixing the same after duly repaired including testing complete all as specified and directed. NOTE:- (i) Spares renewed will be measured and paid separately as "Supply only". The rate quoted is deemed to include for minor spares. (ii) Labour charges for dismantling / taking down and replacement / refixing new parts required is deemed to be included in unit rate quoted.
1
-
-
... More
Supply only spare parts to incorporate in Item No. 63 above :-
(a) Field winding
1
-
-
... More
(b) Armature assembly
1
-
-
... More
(c ) Pinion assembly
1
-
-
... More
(d) Solenoid coil
1
-
-
... More
(e) carbon brush
2
-
-
... More
(f) Clutch set assembly
1
-
-
... More
Supply only Petroleum Jelly in 1 Kg plastic sealed container complete all as specified and directed.
1
-
-
... More
Material and labour for solenoid coil for fuel pump 12/ 24 volts complete all as specified and directed.
1
-
-
... More
Material and labour for power contactor coil for any type of contactor up to 100 Amps to 200 Amps complete all as specified and directed.
1
-
-
... More
Material and labour for power contactor coil for any type of contactor up to 250Amps to 400 Amps complete all as specified and directed.
1
-
-
... More
Material and labour for Automatic Voltage Regulator suitable for 100 KVA to 250 KVA DG Set suitable for existing DG Set complete all as specified and directed.
1
-
-
... More
Supply only Grease A-3 Make- Castrol of each 1 kg package complete all as specified and directed.
2
-
-
... More
Shifting of DG set 62.5 to 250 KVA capacity by using necessary T&P including removing all electrical connection with safety and installing the same in same or other location complete all as specified and directed by Engineer-in-Charge
1
-
-
... More
Servicing / routine maintenance of AMF panel for DG sets by checking of fastener,checking of shock absorber for leakage,checking of top and bottom trip free mechanisam,closing and tripping spring assembly & split pin,spring cut off micro switches.,earth fault relays ,under voltage relays complete all as specified and directed.
Note: Renewal of any spare part will be measured and paid separatelyas "Supply only"
5
-
-
... More
(a) Supply only VAF meter for AMF Panel of DG Set Make:- L&T
2
-
-
... More
(b) Supply only Line Voltage Magager (LVM) for AMF Panel of DG Set Make:- L&T
2
-
-
... More
(c) Supply only Earth fault relay for AMF Panel of DG set Make:- L&T
1
-
-
... More
(d) Supply only Closing coil for AMF Panel of DG set Make:- L&T
2
-
-
... More
(e) Supply only Shunt Trip for AMF Panel of DG set Make:- L&T
2
-
-
... More
( f) Supply only Single phase polyester resin cast CTs for AMF Panel of DG set.
Make:- L&T
2
-
-
... More
(g) Supply only Compact UVT Coil for AMF Panel of DG set. Make:- L&T
2
-
-
... More
(h) Supply only Auxiliary switch for AMF Panel of DG set. Make:- L&T
2
-
-
... More
Supply and fix hose box (fire hose cabinet) for keeping 2 Nos hose pipe with coupling of length 30 meter each, made of 3mm MS sheet 750mmx600mmx250mm with double door with 4mm thick glass and door frame made of 2mm MS sheet powder coated painted with synthetic enamel paint of fire red shade out side and brilliant white inside including lock and key arrangement and suitable angle stand complete all as specified and directed. Make : Newage or techno commerical equivalent make.
30
-
-
... More
Material and Labour for ISI marked RRL (IS :636 type-II) fire hose pipe 30 meter long and 63 mm dia with ISI marked (IS : 903) gun metal male and female coupling as required complete all as specified and directed.
30
-
-
... More
Supplying and fixing Gun metal 63 MM. dia. Instantaneous pattern short branch pipes & 12.5 mm dia. Nozzle suitable for inter connections to hose pipe coupling as required ISI marked complete all as specified and directed.
30
-
-
... More
Supply and fix Sump /Valve pits covers etc by using 3mm thick MS black plain sheet along with frame by means of Angle Iron 50mmX50mmx6mm and including MS twisted/round bar of size 6mm, 30cm long for handle including making locking arrangement all complete with welding, grinding etc including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
80
-
-
... More
Material and Labour for fire hydrant post 100 mm dia with both end flanged,1.5 mtr long suitable for (Type B) double fire hydrent valves including painting with two coats of fire red colour synthetic enamel paint over one coat of zinc chrome primer paint complete all as specified and as directed.
20
-
-
... More
Material and Labour for fire hydrant valve assembly 63 mm dia with single flanged end pattern confirming to IS-5290 type"A" including neoprene gasket, nuts bolts washer including dismantling of unserviceable fire hydrant complete all as specified and directed. .Make:-Newage/Vir/Kartar
4
-
-
... More
All as per item No 91 above but double flanged end type B pattern complete all as specified and directed
20
-
-
... More
.
(a) Supply only CI operating Wheel suitable for fire hydrant valve assembly 63mm dia as per existing complete all as specified and directed.
4
-
-
... More
Supply only Stainless Steel Spindle suitable for fire hydrant valve assembly 63mm dia as per existingcomplete all as specified and directed.
4
-
-
... More
Supply only Female coupling with Neoprene washers suitable for fier hydrant valve assembly 63mm dia as per existing complete all as specified and directed.
10
-
-
... More
Material and Labour for prepration of steel surface and applying one coat of synthetic enamel paint of red post office shade to the MES fire hose box of size 30"x24"x10" with and including MS angles and name plate clearly indicating HYDRANT NO complete all as specified and directed by Engineer-in-charge.
30
-
-
... More
All as per item No.96 above but of size 36"x30"x10'' complete all as specified and directed by Engineer-in-charge.
20
-
-
... More
Material and Labour for prepration of old steel surface and applying one coat of synthetic enamel paint of red post office shade to pipes above ground level of different sizes of fire/deluge system complete all as specified and directed by Eng-in-charge.
40
-
-
... More
Material and Labour for cleaning of static water tank semi under ground sump open type capacity 1.40 lakhs ltrs by draining out complete residual water, scrapping the internal surface of walls of tanks with wire brush / brooms, for removing the fungus, algae particles , soil, sludge mud etc complete including rewashing the walls of tank with fresh water to ensure complete cleaning including white washing 2 coats on old surface and writing on the outer walls of the tank with synthetic enamel paint the date of cleaned, due date of next cleaning complete all as specified and directed including followings:-
(a) Preparation of old surface shall include brooming or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots.
(b) Provision of electric motor for dewatering of residual mud water from sump.
15
-
-
... More
Supply and fix Conventional smoke detector with base plate complete all as specified and directed. Make System Sensor
30
-
-
... More
Supply and fix Conventional Heat detector with base plate complete all as specified and directed. Make System Sensor
20
-
-
... More
Supply and fix high Beam detector with base plate complete all as specified and directed. Make System Sensor
2
-
-
... More
Supply and fix Hooter cum strobe complete all as specified and directed. Make System Sensor
3
-
-
... More
Supply and fix Manual Call point semi addressable complete all as specified and directed. Make System Sensor
2
-
-
... More
Taking up or down CI/DI/MS pipe 80/100mm including removing of all necessary connections/fittings at any place, complete all as specified and directed by Engineer in Charge. Note :excavation and earth work will be measured & paid separately
44
-
-
... More
All as per item No 110 but 250 mm dia
22
-
-
... More
Supply, errect, test & commissioning 100 mm dia M.S. pipes (Class "C") ISI marked and specials etc. for laying raiser at shaft any height above ground/along the wall for hydrants system including transportation of materials upto the worksite, cutting the pipes to required length, edge preparation, welding, fixing / errection of pipes with suitable flat/angle iron including specials i.e. bends, tees, reducers, flanges etc. in proper position including fixed on walls/ceiling with heavy duty U-bolts on M.S.brackets with anchor fasterners, including, jointing by welding, aligning the pipe line, painting with a red oxide primer coat and two coats of synthetic enamel paint fire red colour, providing tapping for pressure gauges and for other instruments etc as required . complete as as specified and as directed.
NOTE:- (i) The quoted rates shall also include for making holes in masonry/ RCC slab, wall, chases in wall etc. & making good the same to original conditions.
(ii) welded joints with MS fittings shall be provided which shall be deemed to be included in the unit rates quoted by contractor.
33
-
-
... More
Material and labour for DI pipes 250mm with spigot and socket ends centrifugally cast , Class K 07 in any length any type laid in trenches / laid in floors complete all as specified and directed.
22
-
-
... More
All as per item No 108 above but 80 mm dia complete all as specified and directed.
11
-
-
... More
Supply and fix CI/DI fitting for spigot socketed pipes such as Bends (any type, radius an angle) Tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch, `Y' junction, double branch, cross (all sockets or flanged ) collars, caps and plugs of size upto 300 bore mm complete all as specified and directed.
80
-
-
... More
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out/laying for GI/CI pipes and getting out in soft soil complete all as specified and directed.
5
-
-
... More
As as per item No 133 above but for Hard / dense soil
7
-
-
... More
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as directed by Engr-in-Charge
11
-
-
... More
Removing excavated surplus soil to a distance not exceeding 50 metre and deposting where directed at a level not exceeding 1.5 metre above the the starting point complete all as specified and directed by Engr-in-Charge
1
-
-
... More
Dismantling / disconnecting unserviceable 80 mm sluice valve assembly complete by removing old nut bolts packing sheet etc and Supply and fix CI sluice valve of dia 80 mm, both end flanged conforming to IS 14846,ISI marked with stainless steel spindle including jointing with 3.0 mm thick rubber gasket,nuts,bolts,washers etc. class PN 1.6 with iron wheel head complete all as specified and directed by Engineer-in-charge.
2
-
-
... More
All as per item no115 but 100 mm dia
6
-
-
... More
All as per item no115 but 150 mm dia
2
-
-
... More
All as per item no115 but 300 mm dia
2
-
-
... More
Dismantling / disconnecting unserviceable 100mm size butterfly valve assembly complete by removing old nut bolts packing sheet etc and Supply & Fix butterfly valve of dia 100mm, jointing with 3.0mm thick rubber gasket, nuts, bolts, washers etc class PIN 1.6 with iron handle complete all as specified and directed by Engr-in-Charge.
4
-
-
... More
All as per item No:119 above but 80 mm nominal bore pipe complete all as specified and directed.
2
-
-
... More
All as per item No:119 above but 50 mm nominal bore pipe complete all as specified and directed.
2
-
-
... More
Supply, intall testing and commissioning of Soft starter suitable for 80 HP fire motor in existing panel board with proper arrangement operational voltage 208-600 V, rated operational current 171 Amps, External keypad rating IP-66 complete all as specified and directed by Engr-in-Chrage
1
-
-
... More
Material and labour for disconnecting the electrical and mechanical connection of burnt electrical motors from the site / location including transporting to work shop, rewinding of electrical motors by dismantling and removing the burnt out copper winding wire, cleaning the slots of stator completely and winding polyster based super enamelled copper wire of same gauge of original one with 'F' class of insulation including varnishing and heating the coil and remove air bubbles complete stator/rotor after rewinding reassembling all parts including reinstalling connection to original position and testing on full load complete all as specified and directed by Engineer in charge for capacity of motor 80HP.
1
-
-
... More
Overhauling the Centrifugal Pump set by dismantling the pump set opening, cleaning, greasing including replacement of spare parts and re-assembling after repairs including required metalling, grinding, etc. reinstalling back to position and testing complete for following capacity of Pump sets as directed by the Engr-in-Charge. Note : (i) Minor spares such as gland packing, gaskets, nuts, bolts, grease, various rings deemed to be included in the quoated rates. (ii) Major spares such as shafts, bearings, impellar, throught bush, coupling will be measured & paid seperately under respective items as " Supply only".
(a) upto 10 HP
1
-
-
... More
(b ) 80 HP
1
-
-
... More
Supply only Shaft sleeve for 10 HP
2
-
-
... More
Supply only Bearing for 10 HP
2
-
-
... More
Supply onlyShaft sleeve for 80 HP
2
-
-
... More
Supply only Bearing for 80 HP
2
-
-
... More
Supply and fixing mechanical joint made out of CI fabricated as per existing site requirement including long MS nut bolt rubber gasket cutting of pipe of any size GI/CI/MS/DI pipe all as directed by Engr-in-Charge for following dia. (Note:- Excavation and returning filling & removal etc is deemed included in quoted rate)
a) 250 mm dia
2
-
-
... More
b) 150 mm dia
2
-
-
... More
Material and Labour for MS flange adopter joint 300 mm including suitable size rubber rings, gasket sheet, nut, bolts and cutting existing pipe etc complete all as specified and directed.
1
-
-
... More
Dismantling of damaged portion of valve pit chamber wall and Material and labour for Brick work with sub class 'B' brick straight or curved on plan exc 6m and built in CM 1:4 complete all as specified and as directed.
4
-
-
... More
Taking down cement plaster from damaged portion of valve pit chamber brick wall surface including racking out joints, hacking for key, scrubbing down with water etc and Material and labour for rendering in CM 1:4 ,10mm thick on fair faces of finished even and fair complete all as specified and as directed.
10
-
-
... More
Supply and Fix 2 core FRLS PVC insulated unsheathed copper conductor armoured cable multistranded 2 X 1.5 sq mm for connecting fire detector, test point and Hooters with control panel complete all as specified and directed.
90
-
-
... More
Supply, install, Testing and commissioning of 8 Zone Electronic Automatic fire alarm / supervisory control palel indoor type operating on 110-220 Volts, 50 Hz AC electric supply including stand by battery backup 24 volt DC complete all as specified and directed
2
-
-
... More
Supply and fix Sealed Maintenance Free battery 12 volt 26 AH including battery Box complete all as specified and directed
4
-
-
Evaluation Notes How It Works ?