Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Eprocure
Opening Date4 Oct 2019
Closing Date13 Nov 2019
Tender Amount₹ 22,00,000
Costs
EMD
₹ 44,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_MES_286804_1Bid Award Id
ViewTender No
8386 / E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
(b) One Fan point controlled by one, one way switch single pole.
20
-
-
... More
(d) One 3 pin 5 Amps socket out let on independent board
20
-
-
... More
(e) One 3 pin 5 Amps socket out let on same board
20
-
-
... More
All as per item No 2 (here-in-before) but with 2.5 Sqmm Copper conductor cable for one 3 pin, 15 Amps socket out let on independent board.
20
-
-
... More
S&F switch piano flush type 230/250 Volt, 5 Amps single pole one way, etc complete all as directed by Eningeer-in-Charge
200
-
-
... More
S & F fan Regulator switch type- Dimmer on the existing phenolic laminated etc. as reqd single pole 240 volts grade 100 watts heavy duty ISI marked. etc complete all as directed by Eningeer-in-Charge
20
-
-
... More
S&F switch socket combination multi purpose 2 in 1, 6 pin 5 Amps, flush type, ISI marked etc complete all as directed by Eningeer-in-Charge
40
-
-
... More
S&F switch socket combination 5 in 1 ,5Amp/15 Amp, flush type, ISI marked etc complete all as directed by Eningeer-in-Charge
20
-
-
... More
S&F ceiling rose surface bakelite three terminal etc complete all as directed by Eningeer-in-Charge
180
-
-
... More
S&F Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings etc complete all as directed by Eningeer-in-Charge
20
-
-
... More
S & F in replacement double door Sheet metal enclosures factory made DBs 8 way ,240 volts ,protection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management, Fully shrouded Neutral bars, Prefitted masking sheet etc complete all as specified and directed by Eningeer-in-Charge Make: Legrand , Cat No: 5076 11 or equivalent in Simens/ Hager/ L & T / Havells as approved by GE
8
-
-
... More
S & F in replacement double door Sheet metal enclosures factory made DBs 4 way , 415 volts ,protection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet etc complete all as directed by Eningeer-in-Charge Make: Legrand ,Cat No:5076 70 or equivalent in Simens/ Hager/ L & T / Havells as approved by GE
2
-
-
... More
S & F MCBs of the under mentioned type and rating and fixing in DBs (DBs measured and paid for separately) etc complete all as specified and directed by Eningeer-in-Charge
(Note :- Make of the isolator should be the same as that of DB) for the following :
-
-
-
... More
(a) MCB Single Pole of 240 volts 5-32 Amps,10 KA Capacity, 'C' Series Make: Legrand ,Cat No: 4085-87 to 90, 92, 93, 94, 95 or equivalent in Simens / Hager / L & T / Havells asa approved by GE.
48
-
-
... More
(b) MCB Single pole + Neutral 240 volts, 32 -63 Amps,10 KA Capacity, 'C' series Make: Legrand ,Cat No: 4086-17 to 20 or equivalent in Simens/ Hager/ L & T / Havells as approved by GE
16
-
-
... More
(c) MCB Triple pole + Neutral 415 Volts ,40 -63 Amps,10 KA Capacity, 'C' series Make: Legrand ,Cat No: 4086-81 to 83 or equivalent in Simens/ Hager/ L & T / Havells as approved by GE
2
-
-
... More
Taking down Existing tube light fitting & Supply & fix Endura LED Batten fitting 20 watt with minimum 2000 lumen output with 6500 K including connecting up with three core twisted flexible copper conductor cable with suitable size from ceiling rose to fitting etc complete all as specified and directed by Eningeer-in-Charge Make :- Jaguar ,Cat No. LGLZ01X020XC or equivalent in Phillips / Wipro / Havells as approved by GE
120
-
-
... More
Taking out old building security light ( HPSV/Tube light fitting) & S & F LED bldg security light minimum 25 Watt with minimum 2500 lumens with 6500K and New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium roadway luminaire with high power LED as light source of capacity 25W LED 5000K of Make Jaguar CatNo.LTRUMP0025XC or Equivalen in /Philips/Wipro / Havells as approved by GE
20
-
-
... More
Taking out old building security light ( HPSV/Tube light fitting) & S & F LED bldg security light minimum 30 Watt with minimum 3000 lumens with 6500K and New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium roadway luminaire with high power LED as light source of capacity 25W LED 5000K etc complete all as specified and directed by Engineer-in-Charge Make Havells Cat No.LHEWDRP7PN1W025 or equivalent in /Philips/Jaquar/Wipro as approved by GE
20
-
-
... More
Supply and fix insulating rubber matting 6mm thick 2mx1m of 1100 volts grade and all as specified. etc complete all as specified and directed by Eningeer-in-Charge
4
-
-
... More
M&L in replacement for sub main wiring with two runs of PVC insulated and unsheathed FRLS cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 4 Sqmm, single core, copper conductor drawn through and including PVC Casing Caping and 2.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire etc complete all as specified and directed by Eningeer-in-Charge (Note : Two runs of conductor with one run of earth wire and PVC casing capping will be measured & paid as one unit)
100
-
-
... More
Supply and fixing FRP fencing made up with using FRP rod 12 mm dia,channel size 50 x 24 x 4 mm box section 50 x 25 mm 'I' section 38 x 15x3 mm and square box section 50 x 50 mm in post embeded in plain cement concrete (1:4:8) type D2 using 20 mm graded stone aggregate (45 cm x 45 cm x 45 cm) including necessary excavation and earthwork at 1.25 m C/C with height of fencing 2 m from GL including entrance gate of size 1m x 2m of same material.MS aldrop bolt 300 mm long,150 mm size pressed steel handles and 2 Nos tower bolts MS hinges as required etc complete all as specified directed by Eningeer-in-Charge.
Make Sintex or equivalent as approved by GE
Note:- Verticle posts and rail section shall be manufactured of fibre glass reinforcement min 45% and formulation of polystrbased thermoset resigns
68
-
-
... More
Material & labor for earthing complete with galvanized steel earth plate electrode 60x60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to and includingGI strip 32 x 6mm as earth lead up to 7.5 mtr long by means of bolts, nuts, check nuts and washers etc with GI protection pipe of 40mm bore medium grade and connected to earthing test point all as shown in electrical plate No.3 of SSR part-I and as specified or indicated including excavation & earthwork in any type of soil, PCC (1:3:6) chamber, precast slab 50mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4 Kg/Sqm), with frame, funnel with 20mm bore GI pipe medium grade watering pipe, wire mesh and lugs test point etc and testing on completion etc complete all as directed by Eningeer-in-Charge
NOTE:-(i) Items includes the cost of 7.5 metre length GI pipe and earth lead for protection of earth lead.Any variation in length shall be adjusted through deviation order.(ii) On testing,if the earth resistance is not obtained,earthing will be regenerated at no extra cost till the desired earth resistance is obtained.
10
-
-
... More
M & L for Earthing complete with galvanized steel earth plate electrode 60x60cm x 6.0 mm thick buried directly in ground ( earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including galvanised earth lead wire 4.0 mm dia,by means of nuts,bolts,checknuts and washers of galvanized iron including 15 mm bore GI pipe,medium grade up to 7.5 meters long all as shown in electrical plate No.3 of MES SSR part-I and testing on completion including excavation and earth work in any type of soil, PCC (1:3:6) type C1 chamber,precast RCC slab 50mm thick in cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric or XPM,( weight not less than 4 Kg/Sqm), with cast iron frame, funnel with wire mesh,GI watering pipi 20 mm dia medium grade,test point and lugs complete.
NOTE:-(i) Items includes the cost of 7.5 metre length GI pipe and earth lead for protection of earth lead.Any variation in length shall be adjusted through deviation order.(ii) On testing,if the earth resistance is not obtained,earthing will be regenerated at no extra cost till the desired earth resistance is obtained.
10
-
-
... More
Dismantling and taking down/out the burnt out Submersible pump set from Sump of 10 HP Capacity from of sewage installation and transprotation to repairing bay / workshop for replacing damaged parts such as bearings, sleeves, bushings etc. and for rewinding the electric motor with existing gauge,wt., of super enamelled copper wire including insulating, varnishing, heating, re-assembling & testing the motor at workshop, shifting to site and refixing to its original/desired position including reconnecting all the electric connections by replacement of bolts, nuts & washers including foundation bolts after testing to make it functional etc complete all as specified and directed by Eningeer-in-Charge
NOTE : Spares parts reqd to be replaced such as bearings, sleeves, bushings etc.shall be measured and paid separately under relevant items of this BOQ / Schedule `A'.
4
-
-
... More
Supply and fix in replacement Sign boards for MES installations of size 1200 x 900mm made out with angle iron 40x40x6mm as framing covered both side with 2mm thick aluminium sheet rivetting on frame covered with retro reflective sheet & 100mm high letters as directed . The sign board to be fixed on 2 No 40x40x6mm angle iron legs embedded in PCC (1:4:8 ) using 40 mm graded stone aggregate inclunding necessary excavation complete at the Installations etc complete all as specified and directed by Eningeer-in-Charge.
(Note : The Details to be written on board shall be given by the Dept)
14
-
-
... More
M&L in replacement of mild steel plates , plain or chequered, 5mm thick or over, cut, welded as reqd. for cable ducting etc complete all as specified and directed by Eningeer-in-Charge
1300
-
-
... More
M & L for writing MES No of 4cm high letters to DG sets / Transformers / Voltage stabilizer / EOT / HOT cranes / VCB / OCB / RMUs / Panels (LT/HT) etc with red colour radium etc complete all as specified and directed by Eningeer-in-Charge (MES No shall be given by Deptt.).
250
-
-
... More
M&L for sand cushioning to PVC cables in Ducts at MES installations with screened dry river sand and gently punned etc complete all as specified and directed by Eningeer-in-Charge. (Note: Punned thickness shall be measured)
50
-
-
... More
S & F in replacement single pointed air termination aluminum rod 12mm dia , 300mm long long mounted on GI pipe 40mm dia, light grade, embedded in mass PCC etc complete all as specified and directed by Eningeer-in-Charge
(Note: pipe & PCC will be measured seperately under relevant this item of this BOQ / Schedule `A' )
20
-
-
... More
S & F in replacement aluminum strip 25 x 3mm with saddles and fixing screws etc for roof/down conductor above ground including joining with rivets/ botls,nuts,washers etc complete all as directed by Eningeer-in-Charge
200
-
-
... More
S & F in replacement air termination single pointed copper rod 12mm dia ,300mm long mounted on GI pipe 40mm dia, light grade embedded in mass PCC etc complete all as specified and directed by Eningeer-in-Charge
.(Note: pipe & PCC will be measured under seperately under relevant items of this BOQ / Schedule `A')
35
-
-
... More
Supply, fixing and testing in replacement of unserviceable PVC insulated cable 3 Core 16 Sqmm, 1100 Volts grade, heavy duty, multistranded copper conductor for connecting motor to panel board with copper lugs duly encased through and including suitable size PVC pipe fixed to wall / laid in floors etc complete all as directed by Eningeer-in-Charge
80
-
-
... More
All as per item No 36 (here-in-before) but 3 Core, 10 Sqmm cable
80
-
-
... More
All as per item No 36 (here-in-befoe) but 3 Core, 6 Sqmm cable
120
-
-
... More
Supply Laying , jointing and testing ,LT under ground cable ,1100 volts grade,XLPE insulated,armoured with galvanised round steel wire or steel strip,electric power cables heavy duty,with multi stranded aluminium conductor,laid in trenches,ducts,fixed on poles/walls with proper size saddles and clamp laid under roads/path/drain/culverts or encored in GI pipe fixed & testing and commissioning size of cable 70 Sqmm, 3.5 Sqmm including taking down the existing LT cable etc complete all as specified and directed by Engineer-in-Charge.
291
-
-
... More
Excavating in trenches n'exc 1.5 m wide and n exc 1.5m in depth , for foundation , etc n'exc 10 Sqm on plan and n'exc 1.5 mtr depth and getting out on Soft / lose soil etc complete all as specified and directed by Eningeer-in-Charge
54
-
-
... More
Returning, filling in, including spreading , levelling , watering and well ramming in layers not exc 25cm of any soil etc complete all as directed by Eningeer-in-Charge
4
-
-
... More
Removing excavated materials(soils) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point etc complete all as directed by Eningeer-in-Charge
50
-
-
... More
Supply, Laying and testing HDPE pipe 40 mm dia for protection of LT cables etc complete with all accessores etc complete all as specified and directed by Engineer-in-Charge . Make: Vectus Industries/ Supreme/Infra/Astron Plastic as approved by GE.
240
-
-
... More
S & F in replacement 450x 450 x 300 (D) mm,2mm thick poweder coated m.s. box for housing with MCB SPN 32 Amp & timer switches 250V,Single phase of 20 Amp rating with conntactor fitted inside steel enclosure etc complete all as specfieid and directed by Eningeer-in-Charge
7
-
-
... More
S & F in replacement LED Flood light fitting 128 watt etc complete all as specified and directed by Engineer-in-Charge Make Philips ,Cat No:BVP122 LED128 CW FLNB FG XTFC or eq in Wipro/GE /Philips / Havells as approved by GE.
8
-
-
... More
An amount of Rs 47,522.00 shall be deducted rom BOQ on account of schedule of credit
-
-
-