Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date13 Jan 2025
Closing Date3 Feb 2025
Tender Amount₹ 49,97,000
Costs
EMD
₹ 1,00,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_693137_1Tender No
86992/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
TENDER INVITING FOR REPAIRS OF EXTERNAL ELECTRICAL NETWORKS AND LT PANELS IN AOR OF GE DEOLALI.
BOQ Items
... More
Taking down existing defective LT under ground cable of any size from trenches complete all as directed
4200
-
-
... More
Supply, stringing, streaching and binding in replacement with insulator, ACSR conductor (Weasel /ferret/Mink) on HT/LT Poles including providing of necessary jumpers, connecting all existing incoming and out going connections, trimming of trees approximately 2 mtr around conductor etc all as specified & directed.
0.25
-
-
... More
S&F tubing 'light grade' galvanised iron with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete all as specified and directed of 80 mm bore
12
-
-
... More
All as item No-6 above but 50 mm bore
24
-
-
... More
All as item No-6 above but 40 mm bore
40
-
-
... More
Supply, Laying , jointing and testing in replacement of LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection complete all as specified and directed of following size:-
-
-
-
... More
a) 3.5 core 240 sqmm
200
-
-
... More
b) 3.5 core150 sqmm
300
-
-
... More
c) 3.5 core120 sqmm
350
-
-
... More
d) 3.5 core 70 sqmm
300
-
-
... More
e) 3.5 core 50 sqmm
500
-
-
... More
f) 3.5 core 35 sqmm
600
-
-
... More
g) 3.5 core 25 sqmm
700
-
-
... More
h) 4 core 16 sqmm
1200
-
-
... More
j) 2 core 16 sqmm
1200
-
-
... More
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed.
963
-
-
... More
Excavating in post hole size 0.6 Mtr X 0.6 Mtr X 1.65 Mtr depth for installation of LT pole 9 mtr long ,in any type of soil and getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm.
6
-
-
... More
Supply & lay in trenches double walled corugated HDPE pipe 75 mm dia high density for protection of under ground cables( Note: pipe couplers with seal, bends, end covers etc are deemed to be included in rate quoted)
1402.5
-
-
... More
Supply & lay in trenches double walled corugated HDPE pipe 50 mm dia high density for protection of under ground cables( Note: pipe couplers with seal, bends, end covers etc are deemed to be included in rate quoted)
3145
-
-
... More
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed
832.8
-
-
... More
Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
77
-
-
... More
Supply and fix , test , commissioning in replacement of LT weather proof panel board powder coated out door type double door shutter type made out of CRCA 3.15 mm thick outer and 1.6 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outdoor, floor mounting type with closed bus bar , chamber and with aluminium bus bar with necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supply as per CPRI approved including provn of digital ammeter 0-500A, digital voltmeter 0-500Volts, CT's of suitable ratio, indicator lamps R-Y-B,selector switches and internal wiring including making PCC block type 0.4 Mtr above ground level grouting etc all as specified and directed with the following Work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc for new & existing cables and connecting all incomming and out going connections. (The bottom portion of enclosure shall be minimum 45 cm above ground level. legs & depth of the panel should not be less than 45cm).Legs of angle iron should be 100 cm lenth (55 cm below ground and 45 cm above the eground) a) Aluminium bus bar of capacity 400 Amps for Phase-R-Y-B & 400 Amps for neutral -1 No b) MCCB 4 Pole 36 KA , 250 Amp - 1 No (I/C) c) MCCB 4 Pole 18 KA, 63 Amp - 5 Nos (O/G)
4
-
-
... More
All as item No 16 above but with following accessories:- a) Aluminium bus bar of capacity 200 Amps for Phase-R-Y-B & 200 Amps for neutral -1 No b) MCCB 4 Pole 36 KA , 160 Amp - 1 No (I/C)
c) MCB TPN 63 Amp ,10 KA - 4 Nos (O/G)
2
-
-
... More
All as item No 16 above but with following accessories:- a) Aluminium bus bar of capacity 400 Amps for Phase-R-Y-B & 400 Amps for neutral -1 No b) MCCB 4 Pole 36 KA 250 Amp - 1 No (I/C)
c) MCCB 4 Pole 36 KA 160 Amp - 1 No (O/G) d) MCCB 4 Pole 16 KA 100 Amp - 1 Nos (O/G) d) MCCB 4 Pole 16 KA 63 Amp - 2 Nos (O/G)
2
-
-
... More
All as item No 17 above but with following accessories:- a) Aluminium bus bar of capacity 300 Amps for Phase-R-Y-B & 300 Amps for neutral -1 No b) MCCB 4 Pole 36 KA 200 Amp - 1 No (I/C)
c) MCCB 4 Pole 18 KA 100 Amp - 1 No (O/G)
d) MCCB 4 Pole 18 KA 63 Amp - 2 Nos (O/G)
2
-
-
... More
All as item No 16 above but with following accessories:- a) Aluminium bus bar of capacity 200 Amps for Phase-R-Y-B & 200 Amps for neutral -1 No b) MCCB 4 Pole 36 KA , 160 Amp - 1 No (I/C)
c) MCCB TPN 63 Amp ,18 KA - 2 Nos d) MCB TPN 63 Amps-03 e) Astro time switch ( AUTS02AST00 of L&T) suitable for street light control and with 40 Amps ,440 volt coil voltage MNX- 30 contactor ( L&T) 3Ph phase- 0 1 Set
1
-
-
... More
All as item No 16 above but with following accessories:- a) Aluminium bus bar of capacity 400 Amps for Phase-R-Y-B & 400 Amps for neutral -1 No b) MCCB 4 Pole 36 KA , 250 Amp - 1 No (I/C)
c) MCCB 4 Pole 36 KA , 200 Amp - 1 No (O/G) d) MCCB 4 Pole 18 KA 63 Amps - 1 No (O/G)
1
-
-
... More
All as item No 16 above but with following accessories:- a) Aluminium bus bar of capacity 400 Amps for Phase-R-Y-B & 400 Amps for neutral -1 No b) MCCB 4 Pole 36 KA , 250 Amp - 1 No (I/C)
c) MCCB 4 Pole 25 KA , 125 Amp - 3 No (O/G) d) MCCB 4 Pole 18 KA 63 Amps - 1 No (O/G)
1
-
-
... More
All as item No 16 above but indoor type with following accessories:- a) Aluminium bus bar of capacity 400 Amps for Phase-R-Y-B & 400 Amps for neutral -1 No b) MCCB 4 Pole 36 KA , 250 Amp - 1 No (I/C)
c) MCCB 4 Pole 36 KA , 200 Amp - 1 No (O/G) d) MCCB 4 Pole 18 KA 100 Amps - 2 No (O/G)
1
-
-
... More
M&Lin replacement for out door type bus bar chamber fabricated by MS sheet of size 3mm and mounted on MS angle iron frame suitable for 415 Volt 3 phase 4 wire AC supply comprising of Aluminium bus bar of capacity 200Amps installed on epoxy insulators consisting of MCCB TPN,18 KA, 63 Amps-01 No & MCB SPN-32 Amps-06 Nos. the bus bar chamber should be dust proof, vermi proof and made out of 3 mm CRCA sheet and mounted on 40x40x6mm angle iron,.door is front opening with locking arrange ment. duly powder coated.including MS stand, making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed
8
-
-
... More
Supplying, install and errect in replacement in true vertical position steel tubular swaged welded pole in replacement complete with cast iron/MS base plate 6mm thick and of size 300x300mm, final taper, pole cap, bolts, nuts, washers & screws etc. pole made out of ERW M.S. tubing conforming to IS-2713 part-II type 410 SP-31 (9.0 metre long) LT including of holes of reqd Nos and size for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting three signal red colour bends at lower portion of exposed pole starting from plinth block , each band of 300mm height at 300mm spacing, painting pole No the black paint by stenciled letters/figures of 8 cm height complete all as specified and directed by Engr-in-charge. (Note:1. Excavation and PCC works will be measured and paid separatly in respected items.)
6
-
-
... More
M&L for cement concrete 1 : 2 : 4 type B-1 using 20 mm graded aggregate as in foundation , filling and mass concrete necessary form work all as specified and directed. (for transformer platform)
0.4
-
-
... More
M&L for cement concrete 1 : 4 : 8 type D-2 using 40 mm graded aggregate as in foundation for pole including necessary form work all as specified and directed
3.9
-
-
... More
M&L Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts,bolts,washers, welding , bending cold or hot, drilling holes for bolts,in any shape or sizes as indicated or directed and inclusive of one primer coat and two coats of alluminium paint complete all as specified and directed.
0.25
-
-
... More
M&L for scrubbing out old paint, rust etc from 9 mtr steel tubular pole of any size and making smooth and even surface then painting with one coat of anti rust paint and two coat of superior quality aluminium paint on entire exposed portion of pole structure and writing Abbreviated feeder name in 2 " size with white paint on black base all as directed at site(work shall be completed in the stipulated period as directed by Engineer -in-charge).
200
-
-
... More
M&L in replacement of u/s MCCB of 4 pole 63 Amps 415 Volts with breking capacity 18 KA including spreader link complete all as specified and directed by Engr-in-charge.
4
-
-
... More
M&L in replacement of u/s MCCB of 4 pole 100 Amps 415 Volts with breking capacity 18 KA including spreader link complete all as specified and directed by Engr-in-charge.
4
-
-
... More
M&L in replacement of u/s MCCB of 4 pole 125 Amps 415 Volts with breking capacity 25 KA including spreader link complete all as specified and directed by Engr-in-charge.
3
-
-
... More
M&L in replacement of u/s MCCB of 4 pole 160 Amps, 415 Volts, with breking capacity 36 KA including spreader link complete all as specified and directed by Engr-in-charge.
2
-
-
... More
M&L in replacement of u/s MCCB of 4 pole 200 Amps 415 Volts, with breking capacity 36 KA , adjustable type including spreader link complete all as specified and directed by Engr-in-charge.
2
-
-
... More
M&L in replacement of u/s MCCB of 4 pole 250 Amps 415 Volts, with breking capacity 36 KA fixed type including spreader link complete all as specified and directed by Engr-in-charge.
2
-
-
... More
M&L in replacement of u/s MCCB of 4 pole 400 Amps adjustable type, 415 Volts, with breking capacity 50KA including spreader link complete all as specified and directed by Engr-in-charge.
2
-
-
... More
Supply and fix in replacement MCB 4 Pole 63 Amps, 415 volts complete all as specified and as directed.
8
-
-
... More
Supply and fix inreplacement MCB TPN 32 Amps, 415 volts complete all as specified and as directed.
6
-
-
... More
Supply and fix in replacement MCB TP 63 Amps, 415 volts complete all as specified and as directed.
4
-
-
... More
Supply and fix in replacement MCB TP 32 Amps, 415 volts complete all as specified and as directed.
3
-
-
... More
Supplying, fixing, jointing and testing heat shrinkable Straight through joint, with including jointing materials suitable for 1100 V , XLPE LT cable of size 25-50 sqmm , 3.5 core , Incl excavation upto 7 mtrs and returning fillin in after jointing of cable complete all as specified and directed
4
-
-
... More
Supplying, fixing, jointing and testing heat shrinkable Straight through joint, with including jointing materials suitable for 1100 V , XLPE LT cable of size 70-120 sqmm , 3.5 core , Incl excavation upto 7 mtrs and returning fillin in after jointing of cable complete all as specified and directed
3
-
-
... More
Supplying, fixing, jointing and testing heat shrinkable Straight through joint with including jointing materials suitable for 1100 V, XLPE LT cable of size 150-185 sqmm , 3.5 core , complete all as specified and directed
2
-
-
... More
Supplying, fixing, jointing and testing heat shrinkable Straight through joint , with including jointing materials suitable for 1100 V, XLPE LT cable of size 240-300 sqmm , 3.5 core , Incl excavation upto 7 mtrs and returning fillin in after jointing of cable complete all as specified and directed
1
-
-
... More
Trimming of tree branches up to the extent to obtain clearence all around the LT over head lines conductor up to 3 mtr from the conductor on pole including removing of cut branches and clearing the site. Note: tools and cutting equipment to by provided by contractor only.
12
-
-
... More
Cutting through existing bituminous road /PCC/floor/approx size width 50cm X 60cm depth along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finish complete all as specified.
15
-
-
... More
"M&L in replacement earthing GI Strip complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of strata, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified.
42
-
-
... More
M&L for servicing of 1.1 KV LT ACB of 415 Volts 630 Amps by removing from LT panel, dismantling checking the serviceability of parts & replacing the minor unserviceable parts ,oiling/ greasing the moving parts, reassembling, testing and installing to the original position and cheking for correct fuctioning. all as specified and directed at site by Engineer-in-Charge.
4
-
-
... More
M&L for making underground boaring (Manually/Mech) through existing bituminous road/PCC/Floor along cross section approx 10 mtr of the road at a depth approx 1.0 mtr for laying of GI tubing of dia 80/100 mm for encasing of cable all as specified and directed at site.
30
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%