Military Engineer Services Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Security and Emergency Services
Eprocure
Opening Date23 Dec 2023
Closing Date19 Jan 2024
Tender Amount₹ 15,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and fixing of LED strip of Hrs nos of all 4 side watches ( Total 48 Nos)

1

-

-

... More
S&F surface and wall mounted LED batten (LED tube light fitting 20W) with polycarbonate housing & integrated electronic driver alongwith LED tube 20 watt and 02 No PVC square blocks incl taking down old UNSV fitting. Make- Havells cat No LUMILINENXTBS20WLED865SPCWH or equivalent of Philips/ Bajaj/ Crompton Greaves/ Wipro/ Shakti/ Halonix/ Jaquar/C & S/ Bentec India Ltd./ Luker.

20

-

-

... More
Disconnecting the electric supply and opening of the front panel of the dish washing machine strictly as per the manufacturers instructions/guidelines for carrying out inspection of heating and conveyor mechanism for washing of utensils. (skilled technicians from authorised dealer/company rep to be employed), replacement of defective heating kit RE 8230020 (BK) & fixing of front panel, conveyor system, PCB and contractors after carrying out necessary repairs as above, testing & commissioning to the entrie satisfaction of Engr-in-Charge

1

-

-

... More
Supply and fixing Electronic pump 1.1 KW 230/400, IFB Cat Part No -ID911ELELP010

1

-

-

... More
Non comprehensive Maintenance and servicing of Lifts (Make : OMEGA) once in a month including attending faults on call basis for normal repairs including replacement of defective & worn out parts by new spares such as battery, landing hadder, Contactors, relays, gearless drive, ARD, DBRs, PCB etc and greasing of bearings of Lifts as directed by engineer-in Charge. Note : (i) Spares required for above maintenance will be measured and paid separately under relevant item. (ii) Servicing to be carried out as per manufacturer instruction]

-

-

-

... More
Lift of 08 Passangers (544 KG), Location : Viewers Gallery ARN CME Pune

6

-

-

... More
Electrical Inspection

1

-

-

... More
Supply only of cabin door complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
Supply only Governer all as specified and directed by Engineer-in-Charge

1

-

-

... More
Supply only contractor 4 pole 3 tc 44 (Siemens) complete all as specified and directed by Engineer-in-Charge

6

-

-

... More
Supply only Junction Box all as specified and directed by Engineer-in-Charge

1

-

-

... More
Supply only Maintenance Box all as specified and directed by Engineer-in-Charge

1

-

-

... More
Supply only Pensil reed all as specified and directed by Engineer-in-Charge

3

-

-

... More
Supply and fixing Magnet all as specified and directed by Engineer-in-Charge

24

-

-

... More
M&L for ARD elevator emergency automatic rescue device for an event of a power failure or blackout in a building (12 volt 18 amp battries and UPS of 24 watt)

1

-

-

... More
Supply and fixing Cabin shoe set all as specified and directed by Engineer-in-Charge

4

-

-

... More
Periodical maintenance of various conventional/addressable type fire alarm sytems in various bldgs in CME campus including checking, testing, cleaning & services of smoke detector, fire alarm panel, manual call point, hooter and electric circuit complete all as specified and directed. Note :- (i) Spares any if required shall be measured and paid for separately only labour element is deemed to be included in this item.

6

-

-

... More
Supply only photo electric (Optical) smoke detector complete all as specifed and directed.

16

-

-

... More
Supply only zone card upto 4 zone complete all as specified and directed.

4

-

-

... More
Supply only control card complete all as specifed and directed.

2

-

-

... More
Supply only power supply card complete all as specified and directed.

1

-

-

... More
Supply only battery charging card complete all as specified and directed.

2

-

-

... More
Supply only manual call point switches complete all as specified and directed.

5

-

-

... More
Supply only response indicator complete all as specified and directed.

4

-

-

... More
Supply only lead acid battery, 12 Volts, 7 AH complete all as specified and directed.

2

-

-

... More
S&F in replacement fire alarm panel suitable for four zone i.e 4 Nos alarm initiating circuit, type class A or B end of line 3.9 K, loop powered device current 1.8 A alarm current 500 mA double output i.e alarm relay change over voltage frre contract & fault relay change over voltage free contract duly monitored by means of line for sounders, auxillary power out put having autonomy with and including 2 Nos 12 volts 7 A batteries and terminal etc with 12 hours on standby and 30 minutes in alarm condition detection line duly protected from short ciruiting suitable for audio and visual alarm indication, panel conforming to CE and EN 54 part & 4 standard complete all as specified and directed.

2

-

-

... More
S&F in replacement manual call point wall mounted type made of cast aluminium signal red finish suitable for operation on 24 volt DC complete all as specified and directed.

2

-

-

... More
S&F in replacement hooter 40 W suitable for 12-24 volt DC working upto 30 V (for max 30 minutes) having max current consumption of 70 mA sound pressure level 100 db complete all as spefied and directed.

2

-

-

... More
Supply and laying in replacement 2 core copper armoured fire alaram cable 1.5 Sqmm for fire alarm system between and inside different rooms, fixed with and including saddles on wall/ceiling surface d all as specified and directed.

250

-

-

... More
Supply, install, connect, test and commissioning factory made, dust/vermin, weather proof self ventilated, cubical of size 1.8 x 0.50 x1.2 (aps) with front made of and rear opening, hinged door for front,and rear with MS angle iron frame 50 x 50 x 5mm for base support, 3.15 mm thick CRCA sheet, LT panel board, (LT KIOSK), CPRI approved out door, cubicle type, floor mounted, double door with neoprene gasket and locking arrangement with canopy including painting with powder coated on steel surfaces internally & externally and provision of two Nos earth terminals on both sides , cable glands and PCC foundation with PCC 1 : 2 : 4, type B1 , and 30 cm all around the outer dimension of panel including gap for insertion of cable having bottom of panel at height of 90 cms above the ground level with cable entry glands to accommodate and including the following accessories:-

1

-

-

... More
Copper bus bar rectangular 600 Amps full for phase and half for neutral and interconnection of MCCBs to Bus bar mounted on epoxy insulators with colour coding PVC sleeves.-01 job

-

-

-

... More
MCCB 400 Amps, TPN, 415 Volts, 50 Hz ,50 KA- 01 No ( Incoming)

-

-

-

... More
MCCB 250 Amps,TPN, 415 Volts, 50 Hz ,36KA - 01 No ( Outgoing)

-

-

-

... More
MCCB 100 Amps,TPN, 415 Volts, 50 Hz ,36KA - 05 No ( Outgoing)

-

-

-

... More
MCB SPN 32/40A -Each-01

-

-

-

... More
RYB LED Indicator Lamp- Set of Three-01

-

-

-

... More
Volt meter 0-500 Volt with selector switch

-

-

-

... More
Amp meter 0-600 Amp with selector switch with CT-03 Nos

-

-

-

... More
Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs/thimbles on either ends of cable.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.