Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Eprocure
Opening Date3 Dec 2024
Closing Soon31 Dec 2024
Tender Amount₹ 49,80,900
Costs
EMD
₹ 1,00,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repair/maintenance Of Ht Ug Cable, Various Types Of Powerand Distribution Transformers, Ht Breakers And Connected Work Under Ge (cme) Khadki
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_686850_1Tender No
CWE/KKE/TOKEN-68 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Supply, laying, connecting and testing in replacement XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor for 11000 volts working voltage cross sectional area 3 core, 95 sqmm complete all as specified and directed by Engr-in- Charge.
150
-
-
... More
Supply, laying, connecting and testing in replacement XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor for 11000 volts working voltage cross sectional area 3 core 150 sqmm complete all as specified and directed by Engr-in- Charge.
50
-
-
... More
Supply, laying and testing in reapir XLPE insulated screened PVC bedded, galvanised steel strip/ wire armoured, electric power cables (Heavy Duty) with stranded Aluminium conductor, 22000 V grade of following sizes/ cross sectional area complete all as specified and directed including taking down old unsv cable.
-
-
-
... More
3 core 300 Sqmm
30
-
-
... More
3 core 185 Sqmm
60
-
-
... More
3 core 150 Sqmm
25
-
-
... More
3 core 120 Sqmm
50
-
-
... More
S&F in repair cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm
4
-
-
... More
S&F in repair cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm
3
-
-
... More
S&F in repair cable jointing kit for 11 KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm
6
-
-
... More
S&F in repair cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm
3
-
-
... More
S&F in repair cable jointing kit for 11 KV (earthed) grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm
3
-
-
... More
S&F in repair cable jointing kit for 11 KV (earthed) grade cable for straingh through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm.
4
-
-
... More
S&F in repair cable end termination, outdoor, heat shrinkable type joint complete with jointing material and accessories suitable for 22 KV, 3 core 120 to 185 sqmm, XLPE armoured aluminium conductor cable complete all as specified and directed.
3
-
-
... More
S&F in repair cable end termination, indoor heat shrinkable type joint complete with jointing material and accessories suitable for 22 KV, 3 core 120 to 185 sqmm, XLPE armoured aluminium conductor cable complete
4
-
-
... More
S&F in repair cable end termination, straight through joint heat shrinkable type joint complete with jointing material and accessories suitable for 22 KV, 3 core 120 to 185 sqmm, XLPE armoured aluminium conductor cable complete
10
-
-
... More
S&F in repair cable end termination, outdoor, heat shrinkable type joint complete with jointing material and accessories suitable for 22 KV, 3 core, 300 Sqmm, XLPE armoured aluminium conductor cable complete all as specified and directed.
3
-
-
... More
S&F in repair cable end termination,indoor heat shrinkable type joint complete with jointing material and accessories suitable for 22 KV, 3 core, 300 Sqmm, XLPE armoured aluminium conductor cable complete all as specified and directed.
2
-
-
... More
S&F in repair cable end termination,straight through, heat shrinkable type joint complete with jointing material and accessories suitable for 22 KV, 3 core, 300 Sqmm, XLPE armoured aluminium conductor cable complete all as specified and directed.
3
-
-
... More
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, laying cables & pipes etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in following soil strata :-
-
-
-
... More
Soft /Loose Soil
45.29
-
-
... More
Hard/Dense soil
57.32
-
-
... More
Excavating in trenches, n.exc 1.5 m wide ,.exc 1.5m but n.exc 3 m in depth; for foundation, laying cables & pipes etc. n exc 10 sq m on plan and getting out in hard/dense soil complete.
0.1
-
-
... More
Returning filling in including spreading levelling watering and well ramming in n.exc. 25 Cum complete all as directed by Engr-in-Charge.
66
-
-
... More
Removing the excavated material ( soil ) n.exc. 50m and depositing where directed at a level n.exc. 1.5m above the starting point all as directed by Engr-in-charge.
36
-
-
... More
M&L for crushed stone grid for cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge. Note:- Measurement shall be taken after gentling puning.
20.25
-
-
... More
Supply and laying unreinforced precast concrete cable cover, class HV, Type I flat of size 300mm x 180mm x40mm all as directed by Engr-in-Charge
1389
-
-
... More
S&F in repair GI tubing light grade with all fittings for protection of cable laid in tranches or fixing to pole , wall with suitable size of FI clamp complete of following sizes:-
-
-
-
... More
100 mm dia bore
6
-
-
... More
80 mm dia bore
6
-
-
... More
S&F in repair pin type, porcelain, vitreous, white brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade
4
-
-
... More
S&F in repair disc type, porcelain vitreous 145 mm high and 255 mm dia ball and socket type white, brown or green insulator single disc assembly for conductors working pressure 11 KV grade all as directed by Engr-in-Charge.
5
-
-
... More
S&F in repair disc Type, Porcelain, vitreous, white, brown green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts for 22 KV complete all as specified and directed.
4
-
-
... More
S&F in repair pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, for 22KV grade complete all as specified and directed.
6
-
-
... More
S&F lightining arresters expulsion type complete with all fittings transmission class discharge capacity 65 Kilo Amp suitable for 11000 volts complete including taking out old unservicable lightining arrester all as specified and directed.
1
-
-
... More
S&F in repair HT 11 KV outdoor type dropout fuse unit double stack channel type complete with insulator of rating up to 200 Amps complete all as specified and directed.
3
-
-
... More
S&F in repair gang operated air Brake switch triple pole mechanically operated mounted on insulator & steel frame with operating mechanisam worked from ground level suitable for 11 KV for current rating upto 200 Amp of approved make with and including operating rod, GI tubing 25mm dia medium grade single piece of suitable length and insulated handle complete all as specifed by Engineer-in-Charge. Note : AB switch shall consist of three insulators per phase and 9 isolators in all.
4
-
-
... More
S&F in repair lightning arresters expulsion type complete with all fittings transmission class discharge capacity 10 Kilo Amp suitable for 22KV complete all as specified and directed.
1
-
-
... More
S&F in repair HT 22 KV outdoor type dropout fuse unit double stack channel type complete with insulator of rating up to 200 Amps complete all as specified and directed.
2
-
-
... More
S&F in repair gang operated air brake switch triple pole mechanically operated mounted on insulator & steel frame with operating mechanisam worked from ground level suitable for 22 KV for current rating upto 400 Amp of approved make with and including operating rod, GI tubing 25mm dia medium grade single piece of suitable length and insulated handle complete all as specifed by Engineer-in-Charge. Note : AB switch shall consist of three insulators per phase and 9 isolators in all.
3
-
-
... More
M&L for bituminous road cutting to a width of 60cm and depth 90cm for laying of HT cable and making good with PCC M-10 grade (Nominal Mix) using 20mm grade stone aggregate complete all as specified and directed.
1
-
-
... More
M & L for preparing old painted steel surfaces of electric pole of length upto 11 metres including cross arms, bracing, clamps etc and painting with one coat of aluminium paint, retaining & repainting marking on pole & replacement of reflective band of width 4 cm RED-YELLOW-RED alternate coloured 3 numbers complete all as specified & directed by Engr-in-Charge.
11
-
-
... More
M & L for prepairing existing deteriorated old aluminium painted surface and applying a coat of aluminium paint on existing 2 pole structure including cross arms, support angles, clamps and any other structural part complete all as directed by Engr-in-Charge
8
-
-
... More
M & L for prepairing existing deteriorated old aluminium painted surface and applying a coat of aluminium paint on existing 4 pole structure including cross arms, support angles, clamps and any other structural part complete all as directed by Engr-in-Charge
6
-
-
... More
M & L for prepairing existing deteriorated old aluminium painted surface and applying a coat of aluminium paint on existing 6 pole structure including cross arms, support angles, clamps and any other structural part complete all as directed by Engr-in-Charge
4
-
-
... More
M & L for fault detection in damaged HT/LT UG cable by using cable fault detector/locator vehicle mounted comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc to accuracy of 2 meter for various location inside CME for UG cables of any size any type upto 22 KV incl excavation & earthwork in any type of stratra to usually inspect/repair the damaged cable when and where required all as directed by Engr-in-Charge.
Note : (i) Compaint will be notified to contractor on mobile phone at any time and contractor is responsible to rectify the fault within 4 hrs after notification, failing which Rs. 500/- per hrs shall be recovered from contractors. (ii) Rates included necessary earth work in any type of strata or road for opening the cable and prepare the cable ready to jointing work and making good to match with existing finishes.
25
-
-
... More
M & L for Loose filling with aggregates of broken stone gauge 40 to 80 mm in HT substation yard complete including removal of any debris etc all as specified and as directed
8
-
-
... More
S & F in repair danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25 x 20 cm size.
30
-
-
... More
M & L for preparing existing deteriorated old paint steel surface and applying HT bus bar panel and applying a coat of aluminium paint including handles minor parts complete and any other structural part complete all as directed by Engr-in-Charge
8
-
-
... More
M&L for taking out old unsv earthing and material and labour for maintenance free grounding Solution set earthing comprising of Earthing rod , outer pipe in GI and having minimum diameter of 76mm, 3m in length and inner pipe to have minimum diameter of 32mm, both end properly welded to make them airtight. GI terminal size of 100x50x6mm with 2 Nos M8 holes for termination area in between two pipes filled with dry type chemical powder having high conductivity and make sure no air pockets are left. Electrode must be tested for short circuit test of minimum 40 KA at CPRI/NABL. The earthing electrode will be placed in the ground after a bore is drilled to the depth of 3.5 Mtr. The bore drilling will be done with the help of Pneumatic boring machine, 50 Kgs BFC will be placed in the bore to cover the earthing rod from all sides. BFC will be poured in Slurry form in properly mixed condition. The Earth pit cover Square 300x300x240 mm to be provided to cover the earth Pit and shall be made of reinforced FRP and should be capable of carrying the weight of 5 Tons. Make :- U-PROTEC or equivalent in Ashlok earthings/JEF technology NOTE :- (i) Rates of boring 3 Mtr for earth electrode, GI strip 20x3 mm & 40 mm dia protection pipe upto 7.5 Mtr from earth electrode is deemed to be included in the quoted rate. (ii) On testing, after, after completion, if the earth resistance 3 ohms is not obtained, earthing will be rejuvenated at no extra cost till the desired earth resistance is obtained. (iii ) Test certificate from the OEM has to be produced by the contractor for the material used in earthing.
6
-
-
... More
M&L for taking out old unsv earthing and material and labour for maintenance free grounding Solution set earthing comprising of 17.2 mm Pure copper earthing rod, 3m long, Copper terminal size of 100x50x6mm with 2 Nos M8 holes for termination. Electrode must be tested for short circuit test of minimum 40 KA at CPRI/NABL. The earthing electrode will be placed in the ground after a bore is drilled to the depth of 3.5 Mtr. The bore drilling will be done with the help of Pneumatic boring machine, 50 Kgs BFC will be placed in the bore to cover the earthing rod from all sides. BFC will be poured in Slurry form in properly mixed condition. The Earth pit cover Square 300x300x240 mm to be provided to cover the earth Pit and shall be made of reinforced FRP and should be capable of carrying the weight of 5 Tons. Make : "U-PROTEC" or equivalent in Ashlok earthings/JEF technology NOTE :- (i) Rates of boring 3 Mtr for earth electrode, copper strip 20x3 mm & 40 mm dia protection pipe upto 7.5 Mtr from earth electrode is deemed to be included in the quoted rate. (ii) On testing, after, after completion, if the earth resistance 3 ohms is not obtained, earthing will be rejuvenated at no extra cost till the desired earth resistance is obtained. (iii) Test certificate from the OEM has to be produced by the contractorfor the material used in earthing
2
-
-
... More
M&L earth continuity conductor or main earthing lead of size 32x6mm galvanised iron strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to ples or any other indicated situation for loop earthing etc
40
-
-
... More
S&F earth continuity conductor or main earthing lead of size 20x3 mm copper strip fixed to wall with S&F of porcelin /PVC insulator buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as directed by Engr-in-Charge
25
-
-
... More
S&F in repair aluminium conductor, steel reinforced overhead conductors (all sizes) incl binding wire etc complete all directed by Engr-in-Charge
0.5
-
-
... More
Cutting of tree branches/grass and cleaning of sub station compound and removal of all the wasted materials at far distance from sub station, cleaning of ducts including leveling of undulated land complete all as specified and directed by Engr -in-Charge.
6000
-
-
... More
M & L for PCC M-7.5 grade (Nominal Mix) using 40mm graded stone aggregate for foundation of poles complete all as specified and as directed.
0.71
-
-
... More
M & L for PCC M-10 grade (Nominal Mix) using 40 mm graded stone aggregate for copping of poles etc complete all as specified & directed.
0.1
-
-
... More
S & F self-fusing Ethylene Propylene Rubber(EPR) based high-insulating voltage tape of width not less than 2.54 mm (1 inch) and thickness not less than 0.75 mm of any length to protect HT/LT XLPE cable from moisture and current leakage complete all as specified and directed by Engr-in-Charge .
50
-
-
... More
M & L for highly HT insulating opaque red coloured ANTI TRACK COMPOUND SPRAY 320 of MOSIL LUBICANTS that forms flexible chemical resistant coating to class H winding for electrical apparatus, in 500 ml spray bottles to protect HT equipments, bus bar, CTs, PTs from current leakage due to moisture complete all as specified and directed by Engr-in-Charge.
4
-
-
... More
M&L for spraying chemical (glycel) on area to remove unwanted vegitation/grass at various locations as directed by Engr-in-Charge. Note: Equipments to spray chemical on required area are deemed to be included in unit rate quoted.
15
-
-
... More
S & F in repair of unsv HT 11 KV bus bar insulator of HT panel complete as per direction of Engr-in-Charge.
8
-
-
... More
S & F in repair of unsv HT 22 KV bus bar insulator of HT panel complete as per direction of Engr-in-Charge.
8
-
-
... More
M & L for shifting heavy items / excavating / cleaning areas / clearing site by providing crane/hydra/JCB/tractor with trolley as required at site complete all as per direction of Engr-in-Charge.
6
-
-
... More
S&F in repair glow sign board box type printed on poly carbonated sheet of size 200 x 100 x 25 cm having provision of 3 x LED tube light inside the box and 10 mtrs 3 core 1.5 sqmm circular PVC connecting wire with hanging arrangment as directed by engr -in charge.
Note :- Background, font size & colour and material to be printed on board shall be as per direction of Engr-in-Charge.
4
-
-
... More
Taking down burnt out jumpers and M&L for new jumper connection not less than 1.5 Mtr long between bus system to GOD and GOD to DO fuse unit with jumper made of 11/22 KV aluminum conductor (11/22 KV) including clamps, crimple, PVC slveeeves complete all as specifid and directed.
50
-
-
... More
M&L for servicing of 22 & 11 KV GOD & DO fuse unit of any capacity at different sub stations located at CME & at kasarwadi pump house by means of adjustment, alingment, oiling, greasing, conducting jelly etc including new minor spares such as nuts, bolts, wahsers, male/female contact, fix contract jaw, tinned copper flexible jumper 200/400 A capacity, MS jumper carrier, back connector plate, fixed top, bottom contact/L contact for DO unit including replacement of broken post insulator of GOD & DO complete all as specified and directed.
22
-
-
... More
Supply, install, testing and commissioning in repair of factory made outdoor type sheet metal enclosure cable jointing box CPRI & MSEDCL approved of 3 way suitable for HT 11 KV grade 3 phase 3 wire system with 09 Nos epoxy insulators and 03 Nos copper bus bar and made out of 3.15mm powder coated CRCA sheet having gasketed front hinged split doors with bottom detachable gland plate for upto 3 cable entry/exit of size upto 150 sqmm with suitable size of cadmium plated and nuts, bolts and wshers and incl weatherproof, bottom hole, outdoor triple key weather proof pad lockings. The panel shall be of powder coated colour red (one coat) complete all as specified and directed
2
-
-
... More
M&L for filtration/dehydration transformer (voltage grade 22/11, 22/0.433 & 11/0.433 KV ) indooor/outdoor type, mounted on 2/4 pole structure/plinth/substation at site/work shop by dehydration/filtration plant to achieve dielectric strength of 40 KV at 4 mm gap complete all as specified and directed.
Note : i). Contractor is responsible to arrange filtration plant and rate for the same shall be deemed to be included under unit rate quoted. ii). DG set required for operation of filtration plant shall be arranged by the contractor and ate for the same shall be deemed to be included under unit rate quoted. iii) Any damage occurred to transformer during the process of dehydration shall be made good by the contractor to the entire satisfaction of the Engr-in-Charge at his own expenses.
8000
-
-
... More
Supply and pouring new transformer oil as per IS : 335 (1993) for transformers installed at various site for topping up after dehydration to achieve the di electric strength 60 KV at 4 mm gap, complete all as specified and as directed by Engr-in-Charge.
Note : Transformer oil shall be brought at site in sealed container from the original manufacturer and shall be opened in front of Engr-in-charge, Container shall be deposited by the contractor to the deptt, which will be returned after completion of contract.
1200
-
-
... More
M&L for disconnecting the HT & LT connections and taking down of existing Indoor/Outdoor transformer mounted on 2/4 pole structure/plinth/substation for opening of top cover in situ or at wksp by unscrewing all nuts, bolts & wahsers draining out transformer oil upto required level and keeping in clean container for replacement of HT/LT bushings, for repair of tap changer gas kit, for lifting of core assy, for cleanning/repair and refixing complete with new cork sheet gasket, existing/new nuts, bolts & washers for transformer indoor/outdoor type, refilling of oil all as specified and directed for transformer capacity 11/0.433 KV upto 500 KVA Note for item No 63 to 65
(i) HT/LT bushings studs, nuts, bolts & washers required shall be measured and paid seprately under relevant item of this BOQ.
(ii) The rate quoted for the item includes the following :-
(iii) Arrangement of manpower, tools , plants , crane and recovery vehicle for transportation and shifting of transformer to work shop and back if found defective.
(iv) Toping up of transformer oil, replacement of transformer oil as required basis under intimation to the department (Transformer oil will be measured and paid seperately).
(v) Re-winding of transformer and replacement of defective part shall be carried out only after inspection and recommendation of Engr-in-Charge (Rewinding of Transformer shall be paid separately) (vi) Any damage occurred to transformer during the process of disconnecting/taking down/transportation, shall be made good by the contractor to the entire satisfaction of the Eng-in-charge at his own expenses.
1
-
-
... More
All as per item No 65 above but voltage grade 22/0.433KV capacity 63 KVA to 750 KVA.
1
-
-
... More
All as per item No 65 above but voltage grade 22/11KV capacity 3000 KVA.
1
-
-
... More
M&L for replacement of HV porcelain bushing with packing and bush rod for outdoor/indoor type transformer in situ/wksp complete with brass stud rubber bush washers, nuts check nuts and cork sheet gasket for the rating upto 500 KVA, 11/0.433KV transformer complete all as specified and directed. Note : Opening of top cover measured separately
1
-
-
... More
M&L for replacement of LV porcelain bushing with packing and bush rod for outdoor/indoor type transformer in situ/wksp complete with brass stud rubber bush washers, nuts check nuts and cork sheet gasket for the rating upto 500 KVA, 11/0.433KV transformer complete all as specified and directed. Note : Opening of top cover measured separately
1
-
-
... More
M&L for replacement of HV porcelain bushing with packing and bush rod for outdoor/indoor type transformer in situ/wksp complete with brass stud rubber bush washers, nuts check nuts and cork sheet gasket for the rating upto 750 KVA, 22/0.433KV transformer complete all as specified and directed. Note : Opening of top cover measured separately
1
-
-
... More
M&L for replacement of LV porcelain bushing with packing and bush rod for outdoor/indoor type transformer in situ/wksp complete with brass stud rubber bush washers, nuts check nuts and cork sheet gasket for the rating upto 750 KVA, 22/0.433KV transformer complete all as specified and directed. Note : Opening of top cover measured separately
1
-
-
... More
M&L for replacement of HV porcelain bushing with packing and bush rod for outdoor/indoor type transformer in situ/wksp suitable for 22 KV grade complete with brass stud rubber bush washers, nuts check nuts and cork sheet gasket for the rating upto 3000 KVA, 22/11KV transformer complete all as specified and directed. Note : Opening of top cover measured separately
1
-
-
... More
M&L for rewinding of HV/LV coils suitable for 22 & 11 KV grade with new DPC/super enamelled copper wire having class-F insulation as per existing size and turns for any capacity and type of transformer
100
-
-
... More
M&L for silica gel grain complete all as specified and directed.
20
-
-
... More
Supply only mild steel screw bolts(machine made) with hexagonal head at one end and screwed the other with washer and one hexagonal nut n.exc 5 cm long and 5 to 10mm dia of neck
5
-
-
... More
M&L for replacement of Tap changer wheel assy having 7 position of transforemer including dismantling and taking out old unserviceable one complete for transformer 11/0.433 KV.
1
-
-
... More
M&L for replacement of breather assembly made with plycarbonate base and clear aclylic glass of size min 50mm dia, min 120mm long for transformers 22/0.433 KV and 11/0.433 KV complete all as specified and directed.
4
-
-
... More
M&L for replacement of transformer temperature gauge dial type having temp range 0 to minimum 120 degree celcius complete all as specified and directed
1
-
-
... More
Material and Labour for preparing steel surfaces of transformer of capacity up to 750 KVA and applying two coats of synthetic enemalled paint with spray painting machine with existing tinit from outside complete all as specified and as directed by Engr-in-Charge.
Note. i). Painting of transformer shall be carried out for plinth mounted and pole mounted transformer. ii) Necessary tools and plants shall be arranged by the contractor. iii) After completion of painting HT/LT outdoor bushing cable termination joint, oil inspection glass and name plates to be made clean using cleanner.
iv) Contractor shall arrage electric supply for spray machine during painting.
25
-
-
... More
M&L for disconnecting and shifting of transformer/HT VCB from one location to another location inside CME Campus and making connections all as specified and directed.
1
-
-
... More
M&L for servicing, testing and calibration of buchholz relay installed for transformer upto 3 MVA power transformer step down 22/11 KV for safe operation of transformer at site incl connection of relay complete all as specified and as directed by Engr-in-Charge. Note: (i) This item shall be carried out through certified authority and provide certificate/report of calibration. (ii) All type of tools, equipments, labour and machinery are deemed to be include under unit rate rate quoted
2
-
-
... More
M&L for servicing of HT VCB/SF6, 22/11 KV circuit breaker of any capacity after disconnecting HT supply for servicing, repair, replacement of defective/worn out componenets and reassembling complete compreising of the following including testing and commissioning to the entire satisfication of Engr-in-Chage:- (i) Dismantling the HTCB from the enclosure consisting of vacuum interrupter assembly, socket contacts checking the serviceability of the parts carefully including cleaning, adjustments, replacement of defective/worn out parts and reassembling the units complete. (ii) Cleaning the external surface of bushings with cleaner or liquid amonia to remove the accumulation of dirt or any other deposits, inspection of bushings and make sure that vibration due to breaker operation have not caused the busings to move resulting misalingment of contacts. (iii) Checking the vaccum interrupter assembly and contacts, checking the alignment of contacts and setting the contact surfaces to bare firm and unitorm pressure and adjustment the gap as per manufacturers tolerance and replacement of badly spotted contacts. (iv) Checking the breaker bushing of bus bar and circuit side inspecting the internal surface carefully for any charging/trackings, replacement of bushings etc. (v) Dismantling the spring charging mechaniism of the HTCB, checking the operatings of the closing/tripping through closing/tripping coils electricall as well as manually charging including cleaning adjustments and replacement of defective/worn out parts reassembling complete. (vi) Checking the condition of the spring charging motor along with gear box including servicing to motor commutator bushes lubrication of bearing surfaces etc. (vii) Checking the ratchet wheet assembly, driving and charging parts including replacement of defective ratchet wheet and parts. (viii) Checking the operation mechansim of the breaker and ensure its operation freely through entire stroke. parts which shows excessive wear and tear to be replaced or adjusted as per manufacturers tolerance.
16
-
-
... More
(ix) Review the adjustment of all pressure switches and lockout devices. (x) Inspecting all bolts nuts, pins and coller pin are in place and they are open/close properly. Note :- (a) Spares to be replaced shall be meausred ands paid sperately as supply only. under relevant items. (b) Make of HTCB 22/11 KV - ABB/Kirloskar/Schnieder (c) Measurement of resistance value tools labour, petrolium jelly are incl in the quoted rate of the item.
-
-
-
... More
S&F following material for 400/630 Amps HTCB 22/11 KV of make ABB/Kirloskar/Schnieder complete:- Note:- i) Spares shall be meausred ands paid sperately as supply only as under. Ii) Labour shall be deemed to be included under item No.83 above.
-
-
-
... More
Spout for 22 KV HT VCB model VD4
3
-
-
... More
Housing of pole assembly for 22 KV VCB model VD4
1
-
-
... More
Pole assembly (vacuum bottle assembly/vacuum interrupter assembly) for 22 KV VCB model VD4
1
-
-
... More
Pole assembly (vacuum bottle assembly/vacuum interrupter assembly) for 11 KV VCB of make kirloskar/schinieder
1
-
-
... More
Space heater (strip type) for HTCB with connecting arrangement
16
-
-
... More
Shunt closing coil 24 V/110 V for 22/11 KV HTCB
4
-
-
... More
Shunt tripping coil 24 V /110 V for 22/11 KV HTCB
4
-
-
... More
Spring charge motor 220-250 V AC/DC suitable for 22/11 KV HTCB
3
-
-
... More
Tulip contact 8/12 fingers for HT CB 22/11 KV
1
-
-
... More
Isolating contact finger type -2 for HTCB
1
-
-
... More
TNC switch with assembly as per existing for HTCB of ABB/Kirloskar/ Schinieder
2
-
-
... More
PT fuse of capacity 22 KV suitable to fit on existing PTs in 22 KV VCB
2
-
-
... More
PT fuse of capacity 11 KV suitable to fit on existing PTs in 11 KV VCB
2
-
-
... More
48 pin plug socket with wiring including interlock assembly for 22/11 KV HTCB
1
-
-
... More
Phase indicating lamp R-Y-B
15
-
-
... More
Shutter/door locking handle with locking assembly
2
-
-
... More
Lithium battery for relay any type or size
10
-
-
... More
Repair/maintenance/reconditioning of breaker in-out trolly including proper alignment of wheels, wheel moving channel/rail, ramp etc, repairing of stoper pins locking pins, replacement of damaged wheels fixing base etc complete for smooth opertion of trolley for in/out and up/down etc complete all as specified and direct. Note:- The unit rate quoted shall deemed to include for necessary welding, bending, strengthning work if required as per site requirement.
5
-
-
... More
M&L for disconnecting and taking out IDMT/numerical/micorporcessed relay any type or make (1 No UV/OV+1 No earth fault/over current + 1 No master trip relay) overhauling/repairing, testing, calibrating the relay by conducting primary and secondary injection test, checking with CT, rectification of defect in control wiring for proper tripping of circuit brakers through CTs, relays and tripping coil, adjustment/setting to plug and time multiplier settings of the relay to achieve the discrimination in tripping time of upstream brakers, re-installation of the relay in circuit complete all as specified and directed. Note : i). Standby electric supply required during calibration of relay shall be arranged by the contractor in quoted rate of item. ii). Rates for necessary testing kit, testing equipments, tools etc are included in the unit quoted rate adn detail test report shall be submitted to Engr-in-Charge without any extra cost.
16
-
-
... More
Taking down unserviceable relay and supply, intall, testing and commissioning of combined over current and earth fault relay of make ABB/Ashida incl uding fixing in HT panel with necessary control wiring.
1
-
-
... More
S&F digital type multifunction meter VAF, PF, 3 phase 4 wire AC 440 volts 50 Hz of rating 60 Amps with class 1.0 complete all as specified and directed.
8
-
-
... More
S&F in repairs 22 KV epoxy resin cast HT CT with two stage tapping of ratio 30/1 & 50/1 for protection, metering class 1.0 as per existing size/shape suitable for optimum performance of relay.
2
-
-
... More
S&F in repairs 11 KV epoxy resin cast HT CT as per existing ratio (30/1, 50/5, 125/5 etc) for protection, metering class 1.0 as per existing size/shape suitable for optimum performance of relay.
1
-
-
... More
S&F in repairs 22000/110V epoxy resin cast HT PT as per existing burden or as per existing size/shape suitable for optimum performance of relay.
1
-
-
... More
S&F in repairs 11000/110V epoxy resin cast HT PT as per existing burden or as per existing size/shape suitable for optimum performance of relay.
1
-
-
... More
M&L for preparation of steel surfaces of existing HT circuit breaker/SF6 braker/RMU unit, removing all the scrapped paint particals from the panel using the proper vacuum cleaner to the entire satisfication of Engineer-in-Charge and applying two coats of synthetic enamelled paint by using spray machine to finish the surface glossyfinish of tint as approvedby GE including marking of SM/MES number, incoming and outgoing, to and from etc complete all as specified and directed.
7
-
-
... More
Taking down the HT SF6 RMU 22/11 KV (2 incoming and 2 outgoing or 02 incoming and 1 outgoing type) of capacity upto 800 Amps after disconnecting HT supply for servicing, repair, replacement of defective/worn out componenets and reassembling complete compreising of the following including testing and commissioning to the entire satisfication of Engr-in-Chage:- (i) Checking the serviceability of the parts carefully including cleaning, adjustments, replacement of defective/worn out parts and reassembling the units complete. (ii) Cleaning the external surface of bushings with cleaner or liquid amonia to remove the accumulation of dirt or any other deposits, inspection of bushings and make sure that vibration due to breaker operation have not caused the busings to move resulting misalingment of contacts. (iii) Checking the SF6 bottle/tank for any leakage and repair/replace the same and refilling the SF6 gas as per manufacturers tolerance. (iv) Checking the operating mechanism for smooth function and replacement of worn out parts. (v) Dismantling the spring charging mechaniism, checking the operatings of the closing/tripping through closing/tripping coils electrically as well as manually charging including cleaning adjustments and replacement of defective/worn out parts reassembling complete.
8
-
-
... More
(vi) Checking the condition of the spring charging motor along with gear box including servicing to motor commutator bushes lubrication of bearing surfaces etc. (vii) Checking the pressure gauge for SF6 gas and repair/replacement of same for smooth funictioning. (viii) Inspecting all bolts nuts, pins and coller pin are in place and they are open/close properly. Note :- (a) Parts will be replaced under relevant items. (b) Make of SF6 breaker - ABB & AREVA (c) Measurement of resistance value tools labour, petrolium helly are incl in the quoted rate of the item.
-
-
-
... More
S&F following material for 400/630/800 Amps HT 22/11 KV SF6 RMU of make ABB/AREVA complete:- Note:- i) Spares shall be meausred ands paid sperately as supply only as under. Ii) Labour shall be deemed to be included under item No.94 above.
-
-
-
... More
Spring chage motor for 22 KV RMU (02 incoming and 1 outgoing) type of ABB make
2
-
-
... More
Lithium battery for relays any type
10
-
-
... More
Refilling of SF6 Gas
3
-
-
... More
Pressure gauge for SF6 gas as per existing
1
-
-
... More
Operating handle with assembly
2
-
-
... More
RYB phase indicating lamp
10
-
-
... More
Repair/replacement of male female operating mechanisum
2
-
-
... More
M&L for bottle fuse 25 Amps capacity suitable for 22 KV LBS unit complete all as specified and directed.
3
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%