Military Engineer Services Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date17 Jan 2025
Closing Soon12 Feb 2025
Tender Amount₹ 1,39,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Piston rings

2

-

-

... More
Oil rings

1

-

-

... More
Connecting rod bearing half section

2

-

-

... More
Main end bearing with washer

1

-

-

... More
Liner assembly

1

-

-

... More
Gudgeon pin bush

2

-

-

... More
Rocker arm frame

1

-

-

... More
Rocker arm

1

-

-

... More
Loading unloading ring

1

-

-

... More
Suction valve retaining plate

1

-

-

... More
Suction reeds

1

-

-

... More
Discharge reeds

1

-

-

... More
Oil filter inner

1

-

-

... More
Suction strainer

1

-

-

... More
Oil regulating valve

1

-

-

... More
Discharge valve retaining plate

1

-

-

... More
Crank Shaft

1

-

-

... More
Oil pump Assembly

1

-

-

... More
Connecting rod

2

-

-

... More
-Ditto - all as per item No. 1.00 above but for compressor of make : Voltas Model No ACC WC03000 MNT -01 No. 35 TR capacity

1

-

-

... More
Replacement of the following items suitable for compressor of Model No ACC WC03000 MNT as per OEM specifications installed at COMCEN

-

-

-

... More
Piston

2

-

-

... More
Piston rings

2

-

-

... More
Oil rings

1

-

-

... More
Connecting rod bearing half section

2

-

-

... More
Main end bearing with washer

1

-

-

... More
Liner assembly

1

-

-

... More
Gudgeon pin bush

2

-

-

... More
Rocker arm frame

1

-

-

... More
Rocker arm

1

-

-

... More
Loading unloading ring

1

-

-

... More
Suction valve retaining plate

1

-

-

... More
Suction reeds

1

-

-

... More
Discharge reeds

1

-

-

... More
Oil filter inner

1

-

-

... More
Suction strainer

1

-

-

... More
Oil regulating valve

1

-

-

... More
Discharge valve retaining plate

1

-

-

... More
Crank Shaft

1

-

-

... More
Oil pump Assembly

1

-

-

... More
Connecting rod

2

-

-

... More
-Ditto - all as per item No. 1.00 above but for compressor, Make :- Voltas Model No ACC WC04000 MNT, 40 TR capacity as per OEM specifications installed at NAD.

1

-

-

... More
Replacement of the following items for compressor Model No ACC WC04000 MNT as per OEM specifications installed at NAD

-

-

-

... More
Piston

2

-

-

... More
Piston rings

2

-

-

... More
Oil rings

1

-

-

... More
Connecting rod bearing half section

2

-

-

... More
Main end bearing with washer

1

-

-

... More
Liner assembly

1

-

-

... More
Gudgeon pin bush

2

-

-

... More
Rocker arm frame

1

-

-

... More
Rocker arm

1

-

-

... More
Loading unloading ring

1

-

-

... More
Suction valve retaining plate

1

-

-

... More
Suction reeds

1

-

-

... More
Discharge reeds

1

-

-

... More
Oil filter inner

1

-

-

... More
Suction strainer

1

-

-

... More
Oil regulating valve

1

-

-

... More
Discharge valve retaining plate

1

-

-

... More
Crank Shaft

1

-

-

... More
Oil pump Assembly

1

-

-

... More
Connecting rod

2

-

-

... More
-Ditto - all as per item No. 1.00 above but for compressor, Make: Voltas, model No. AC WC05000MNT, 50 TR capacity.

1

-

-

... More
Replacement of the following items for compressor Model No AC WC05000MNT as per OEM specifications installed at TPW

-

-

-

... More
Piston

2

-

-

... More
Piston rings

2

-

-

... More
Oil rings

1

-

-

... More
Connecting rod bearing half section

2

-

-

... More
Main end bearing with washer

1

-

-

... More
Liner assembly

1

-

-

... More
Gudgeon pin bush

2

-

-

... More
Rocker arm frame

1

-

-

... More
Rocker arm

1

-

-

... More
Loading unloading ring

1

-

-

... More
Suction valve retaining plate

1

-

-

... More
Suction reeds

1

-

-

... More
Discharge reeds

1

-

-

... More
Oil filter inner

1

-

-

... More
Suction strainer

1

-

-

... More
Oil regulating valve

1

-

-

... More
Discharge valve retaining plate

1

-

-

... More
Crank Shaft

1

-

-

... More
Oil pump Assembly

1

-

-

... More
Connecting rod

2

-

-

... More
-Ditto - all as per item No. 1.00 above but for compressor complete for overhauling of compressor,Make :- Voltas, Model No. ACWCURO0400MNT, 40 TR capacity.

1

-

-

... More
Replacement of the following items for compressor Model No. ACWCURO0400MNT as per OEM specifications installed at MWC

-

-

-

... More
Piston

2

-

-

... More
Piston rings

2

-

-

... More
Oil rings

1

-

-

... More
Connecting rod bearing half section

2

-

-

... More
Main end bearing with washer

1

-

-

... More
Liner assembly

1

-

-

... More
Gudgeon pin bush

2

-

-

... More
Rocker arm frame

1

-

-

... More
Rocker arm

1

-

-

... More
Loading unloading ring

1

-

-

... More
Suction valve retaining plate

1

-

-

... More
Suction reeds

1

-

-

... More
Discharge reeds

1

-

-

... More
Oil filter inner

1

-

-

... More
Suction strainer

1

-

-

... More
Oil regulating valve

1

-

-

... More
Discharge valve retaining plate

1

-

-

... More
Crank Shaft

1

-

-

... More
Oil pump Assembly

1

-

-

... More
Connecting rod

2

-

-

... More
-Ditto - all as per item No. 1.00 above but for compressor,make: Voltas, model No. AC WC06000MNT, 50 TR capacity.

1

-

-

... More
Replacement of the following items for compressor of model No. AC WC06000MNT as per OEM specifications installed at MOC

-

-

-

... More
Piston

2

-

-

... More
Piston rings

2

-

-

... More
Oil rings

1

-

-

... More
Connecting rod bearing half section

2

-

-

... More
Main end bearing with washer

1

-

-

... More
Liner assembly

1

-

-

... More
Gudgeon pin bush

2

-

-

... More
Rocker arm frame

1

-

-

... More
Rocker arm

1

-

-

... More
Loading unloading ring

1

-

-

... More
Suction valve retaining plate

1

-

-

... More
Suction reeds

1

-

-

... More
Discharge reeds

1

-

-

... More
Oil filter inner

1

-

-

... More
Suction strainer

1

-

-

... More
Oil regulating valve

1

-

-

... More
Discharge valve retaining plate

1

-

-

... More
Crank Shaft

1

-

-

... More
Oil pump Assembly

1

-

-

... More
Connecting rod

2

-

-

... More
Material and labour for disconnecting condenser for descaling & plugging them & providing of 15 mm tee out let for local circulation of mild acid solution in the condenser (separate container and small pump set to circulate diluted acid solution to be used) pH value of solution to be circulated & to be kept 4 and checking frequently i.e. every one hour during the operation Scalgun WS solution to be used for descaling purpose after 2 to 3 hours of cleaning if ph value remains less than 7 flush with fresh water mixed with sodium carbonate tubes and cleaning with nylon brush after closing the end covers, circulating diluted acid solution as specified above & pH value to be maintained as above & flushing the same with fresh water including recharging of stored refrigerant up to required pressure complete all as specified & directed by Engineer-in-Charge of for the following :-

-

-

-

... More
Condenser of 2 x 50TR Capacity AC Plant at NAD A-63 Naval Dockyard

2

-

-

... More
Condenser of 2 x 60TR Capacity AC Plant at MOC INS ANGRE

2

-

-

... More
Condenser of 3 x 30TR Capacity AC Plant at COMCEN INS ANGRE

3

-

-

... More
Condenser of 2 x 7.5 TR Capacity AC Plant at CCDT (ND)

2

-

-

... More
Condenser of 3 x 40TR Capacity AC Plant at MWC Bldg. No. 173(ND)

3

-

-

... More
Condenser of 2 x 15TR Capacity AC Plant at COMCEN REAR INS ANGRE

2

-

-

... More
M & L for Disconnecting electric connections & removing the electric motor from installed position including, loading, unloading and transporting to authorised OEM l workshop,Taking out the existing burnt winding from the motor and rewinding complete with super enamelled copper winding wire of existing gauge including all insulating material such as insulation paper, sleeves, tape, varnish etc. complete for class 'F' class insulation. Transporting the motor after repair back to the location, reinstalling in original position including alignment, making electrical / water connection, commissioning and testing for 8 hours continuously to check the RPM and functionability etc. to the satisfactory performance complete all as specified and directed by Engg-in-charge for the motors of following capacities NOTE: Any damage caused during handling will be made good by contractor without any extra cost to department

-

-

-

... More
7.5 HP Chiller / Condenser Water Pump Motor .

2

-

-

... More
15 HP Chiller/Condenser Water Pump Motor.

2

-

-

... More
5.0 HP Chiller/Condenser Water Pump Motor.

2

-

-

... More
3.0 HP cooling tower blower induction Motor.

4

-

-

... More
10 HP Condenser/Chiller Water Pump Motor.

2

-

-

... More
15 HP Compressor Motor .

1

-

-

... More
40 HP Motor.

2

-

-

... More
25 HP Motor.

1

-

-

... More
Material and labour for disconnecting of Chiller for descaling by Plugging them with 15 mm tee outlet for local circulation of mild acid solution in the Chiller (separate container and small pump set to circulate diluted acid solution to be used) pH value of solution to be circulated to be kept 4 and checking frequently i.e. every one hour during the operation Scalgun WS solution to be used for descaling purpose after 2 to 3 hours of cleaning if ph value remains less than 7, flush with fresh water mixed with sodium carbonate tubes and cleaning with nylon brush after closing the end covers, circulating diluted acid solution as specified above & pH value to be maintained as above & flushing the same with fresh water including recharging of stored refrigerant up to required pressure complete all as specified & directed by Engineer-in-Charge of for the following :-

-

-

-

... More
Chiller of 2 x 50TR Capacity AC Plant at NAD A-63 Naval Dockyard

2

-

-

... More
Chiller of 2 x 60TR Capacity AC Plant at MOC INS ANGRE

2

-

-

... More
Chiller of 3 x 30TR Capacity AC Plant at COMCEN INS ANGRE

3

-

-

... More
Chiller of 2 x 15 TR Capacity AC Plant at COMCEN REAR INS ANGRE

2

-

-

... More
Material and labour for cleaning of cooling coil section of AHU for descaling and providing 02 Nos.15mm Tee outlet for local circulation of MAIC solution in the cooling coil (separate container and pump set of appropriate capacity to be used for circulation) pH value of solution to be kept at 4 & checked at an interval of 01 hr. duration process the scalgum / WS / Cleansol or equivalent solution to be used for descaling if ph value remains less than '7' flush with fresh water added to sodium carbonate till pH value attains '7' refix the coil section in position minor repairs to be carried out in AHU Coil bins to be cleaned by scalgum solution by spraying the solution with washing pump up to required level, AHU and complete all as specified and directed for the followings :-

-

-

-

... More
AHU of 2 x 50TR Capacity AC Plant at NAD A-63 Naval Dockyard

1

-

-

... More
AHU of 2 x 60TR Capacity AC Plant at MOC INS ANGRE

1

-

-

... More
AHU of 3 x 30TR Capacity AC Plant at COMCEN INS ANGRE

1

-

-

... More
AHU of 2 x 15 TR Capacity AC Plant at COMCEN REAR INS ANGRE

1

-

-

... More
M & L for Dismantling AHU of 2 x 60TR TR capacity AC plant carefully by removing side and top panel , removing unserviceable blower shaft, bearings,removing motor & blower assembly, replacement of new AHU blower shaft, bearings, reassembling blower assembly and refixing electric motor & top, side panel in original position with providing new nut, bolts, washers & shafts keys & checking the shafts balancing & testing for smooth running all as specified and directed at MOC INS ANGRE.

1

-

-

... More
All as per item No 11.00 but for 2 x 50TR AC Plant at NAD A-63 Naval Dockyard.

1

-

-

... More
All as per item No 11.00 but for 3 x 30TR AC Plant at COMCEN INS ANGRE

1

-

-

... More
All as per item No 11.00 but for 2 x 7.5 TR AC Plant at CCDT(ND)

1

-

-

... More
All as per item No 11.00 but for 3x 40TR AC Plant at MWC Bldg No 173(ND)

1

-

-

... More
All as per item No 11.00 but for 6x 7.5 TR AC Plant at A - 14 Bldg (ND)

1

-

-

... More
All as per item No 11.00 but for 2 x 15 TR AC Plant at COMCEN REAR INS ANGRE .

1

-

-

... More
M & L for Pumping down the existing refrigerant from the condensor and carrying out the leak test of plant with the pressure of Nitrogen gas and monoitoring for 24hrs to asses leakages rectification of leak by brazing & replacement of necessary gasket and copper tubes of suitable size wherever directed, vacumizing of the plant by vaccum pump finally recharging of existing refrigerant gas to the plant and topping up of refrigerant if required to maintain the standard pressure etc complete including testing of the plant for smooth functioning complete all as specified & directed. Note: Refrigerant required for topping up will be measured and paid separately under relevant items.

4

-

-

... More
Supply and filling compressor oil as specified and directed by Engr-in-Charge

200

-

-

... More
S & F in repairs Microprocessor of 60 TR Capacity chiller unit including replacing diodes , transistors and wiring of AC Plant at NAD A-63 Naval Dockyard complete all as specified and directed

1

-

-

... More
S & F in repairs Expansion valve of 60TR chiller unit including taking down old unserviceable valve complete all as specified and directed by Engineer-in-Charge .Make: Sporlon or equivalent

1

-

-

... More
S & F in repairs Expansion valve of 40TR chiller unit including taking down old unserviceable valve complete all as specified and directed by Engineer-in-Charge.Make: Sporlon or equivalent

1

-

-

... More
S & F in repairs Expansion valve of AC plant capacity 15 TR including taking down old unserviceable valve complete all as specified and directed by Engineer-in-Charge. Make: Sporlon or equivalent

1

-

-

... More
S & F in repairs Strainer 100mm size complete all as specified.

1

-

-

... More
S & F in repairs Strainer 80mm size complete all as specified.

1

-

-

... More
S & F in repairs Condensor safety valve as per existing and suitable for chiller unit all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S & F in repairs oil pressure cut out controls for compressor of MP 55 Indofoss .

1

-

-

... More
S & F in repairs power contactor MNX -32 all as specified & directed by Engineer-in-Charge

3

-

-

... More
Supply & fix in repairs power contactor MNX -40 all as specified & directed by Engineer-in-Charge.

2

-

-

... More
M & L for Dismantling the leakage condenser coil from 100TR capacity AC plant and providing new air cooled condenser of size 198cm x 112cm x 4 row made out of copper tube and surrounded by aluminium fines. Reconnecting the condenser including brazing/welding with inlet and outlet connections. Leak test, pressure test with nitrogen. Vaccumizing & gas charging with R 22 refrigerant & testing on load complete all as directed.

3

-

-

... More
S & F in repairs oil seal assembly suitable for Unit Model No. ACDR105OMN all as specified and directed by Engineer-in-Charge.

10

-

-

... More
S & F in repairs unserviceable AHU pre-filters 10 microns , suitable for AHUs of Make: Nutech all as specified and directed by Engineer-in-Charge.

25

-

-

... More
S & F in repairs AHU blower motor V belts, size A 36 to A 40 suitable for AHU Blower all as specified and directed by Engineer-in-Charge .

15

-

-

... More
S & F in repairs V belts, size A 43 suitable for AHU Blower all as specified and directed by Engineer-in-Charge a.

18

-

-

... More
Taking down old unserviceable/deteriorated insulation from duct, cleaning the duct surface with steel wire brush to remove dirt, dust and make it free of scale, greases and foreign matter etc and supply and fix nitrile rubber insulation (Armaflex) one layer of 19mm thickness sticking on surface of duct / pipe line by using best quality adhesive and sealing the joints by weather proof tape complete all as directed by Engineer- in- Charge.

50

-

-

... More
S & F in repairs LP/HP cutout switch sensor all as specified and directed by Engineer-in-Charge

15

-

-

... More
S & F in repairs pressure gauge of capacity 0 to 30 Kg / square centimeter complete with necessary accessories all as specified & directed by Engineer-in-Charge

15

-

-

... More
Suuply and fix in repairs air /return air of aluminium rectangular grills complete with wooden frame work made out of II nd class hard wood, volume control damper including gasket and connected accessories complete all as directed by Engineer-in-Charge.

35

-

-

... More
M&L for Cleaning of Air handling ducts (GI/ Al) internally by using special T&P like robortic arm, air compressor, air jet nozzles, flipper, vaccum pump and a suction blower with hepa filter and check before and after the cleaning complete all as specified and directed

400

-

-

... More
S & F in repairs copper tube cooling coils of AHU of capacity not less than 8000 CFM including testing complete all as specified and directed.

6

-

-

... More
S & F in repairs fan assembly made up of aluminium casting with central hub suitable for mounting on shaft of motor for cooling tower of capacity 80TR

2

-

-

... More
Supply and errect factory fabricated rectangular/square duct made out of 24 gauge GI sheet in L shaped hollow profile including all accessories such as corner, carriage bolt hangers, gasket and seal the longitudinal joints with and including approved sealant complete all as specified and directed

40

-

-

... More
Material and labour for framed work with structural steel sections including nuts, bolts,washers, welding ,bending cold or hot, drilling holes for bolts, in any shape or size as directed including applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed

60

-

-

... More
Supply and fix in repairs nitrile rubber insulation of one layer of 19mm thickness sticking on surface by using approved adhesive and sealing the joints by weather proof tape complete all as specified and directed

50

-

-

... More
Supply and fix in repair Chiller Water Sensor suitable for chiller of Capacity upto 50 TR

3

-

-

... More
M & L for Pumping down refrigerant from the compressor, condenser, cooling coil and leak testing by charging of Nitrogen gas in to entire plant and monitoring for 24hrs to find the leakages rectification of leakage by brazing & replacement of gasket packing including vacumizing the system by vaccum pump and keep up 24hrs. for testing and finally restoring and topping up of gas to the plant to maintain the standard pressure complete all as specified.

8

-

-

... More
M & L for removing burnt control wiring complete, rewiring with suitable copper conductor cable replacing the copper lugs, starter of compressor motor, fan motor timer, HP/LP cut outs , thermostat complete , checking the complete function of timer, heaters, relays, HP/LP cut outs, thermostat cut out and inter lock wiring system, testing on load and all wiring shall be mounted on and including cable tray of size hot drip perforated GI 200mm x 50mm complete all as specified and directed.

4

-

-

... More
Supply and fix in repairs fresh air /return air of aluminium rectangular grills of existing size with flap arrangement complete with frame work including gasket and connected accessories complete all as directed by Engineer-in-Charge.

25

-

-

... More
S & F in repairs Microprocessor controller of chiller/ Ductable/ package unit including replacing diods , transistors and wiring as per existing for AC Plant complete all as specified and directed

3

-

-

... More
S & F in repairs Digital control Display Kit Board of chiller/ Ductable/ package unit including replacing diods , transistors and control wiring as per existing for AC Plant as specified and directed

2

-

-

... More
Dismantling of Out door unit covers of VRV/ DUCTABLE AC of any capacity upto 40 HP completly by disconnecting/ covering all electric/electronic boards and wiring and servicing condensor coils and compressor, reservoir areas completly wet servicing by using approved chemicals by OEM manufacturer and re assembling setting all parameters by using softwares by an OEM Engineer testing complete all as specified and directed.

10

-

-

... More
Dismantling of four way high wall indoor/ Cassette unit covers of any capacity completly by disconnecting/ covering all electronic boards and wiring and servicing cooling coils, expansion valves, indoor drainage pumps, drainage lines completly wet servicing by using approved chemicals by OEM manufacturer by using tray jackets including cleaning the surface after servicing, testing complete all as specified and directed.

20

-

-

... More
Supply and charging refrigerant gas (R-22/R-410A/R-132A/134A) suitable as per site requirement.

760

-

-

... More
Supply and fix in repairs harmetically sealed Compressor of 24 HP Capacity, 3 Phase, 415 Volts, 50 Hz, AC for Out door units of Ductable AC Plant including testing complete all as specified and directed.

1

-

-

... More
Supply and fix in repairs harmetically sealed Compressor of 10 HP Capacity, 3 Phase, 415 Volts, 50 Hz, AC for Out door units of Ductable AC Plant including testing complete all as specified and directed.

1

-

-

... More
Supply and fix in repairs harmetically sealed Compressor for Out door units of VRF as per existing cat pt no. of VRF 12 to 18 HP, 3 Phase, 415 Volts, 50 Hz, AC Unit including testing complete all as specified and directed by Engineer-in-Charge.

3

-

-

... More
Supply and fix in repairs mother Board Control for Out door units of VRV Plant of capacity 12 HP including testing complete all as specified and directed.

2

-

-

... More
Supply and fix in repairs MNET Board for Out door units of VRV Plant of capacity 12 HP including testing complete all as specified and directed.

3

-

-

... More
Supply and fix in repairs Noise filter for Out door units of VRF Plant of capacity 12 HP including testing complete all as specified and directed.

3

-

-

... More
Supply and fix in repairs Fan board for Out door units of VRV Plant of capacity 12 HP including testing complete all as specified and directed.

3

-

-

... More
Supply and fix in repairs Invertor board for Out door units of VRV Plant of capacity 12 HP including testing complete all as specified and directed.

3

-

-

... More
Supply and fix in repairs Fan Motor for Out door units upto from 16 to 18 HP of VRV Plant including testing complete all as specified and directed.

2

-

-

... More
Supply and fix in repairs Condensor coil suitable for Out door units of 16 to 18 HP of VRV Unit including leak testing by using nitrogen complete all as specified and directed.

2

-

-

... More
Supply and fixing in repairs special refrigerant Copper tube 'Y' joints for VRV system as per existing complete all as specified and directed.

5

-

-

... More
Supply and fixing in repairs Ceiling Suspended type Inline Fan With Filter for Fresh Air arrangement suitable for VRV system (Cabinet Type Inline Fan) complete all as specified and directed.

2

-

-

... More
Supply and fixing in repairs Rigid PVC Drain Pipe 32 mm dia of 6 Kg./sqcm rating including insulated with 9mm thick nitrile foam rubber stick with adhesive fixed on walls, ceiling, suspended, hanged with all necessary clamps, saddles & supports complete all as specified and directed.

60

-

-

... More
Supply and fixing in repairs refrigerant piping between indoor & outdoor units using suitable size Copper pipes including fittings like elbows, couplers, tee joints, brass fittings, "U" loops, expansion loops etc. supported with GI box / "C" sections & female anchor fasteners with full threaded GI rods at a regular interval of 1 metre c/c, insulation on suction / liquid pipes using 19 mm thick elastometric closed cell Nitrile Rubber insulation material and covered with Aluminium foil (Exposed copper Piping Shall be covered with Aluminium Foil & not exposed copper piping without Aluminium foil) & having class "O" for fire safety, structural clamps with hard PVC pipe sleeves under the clamps to protect insulation at supports complete all as specified.

50

-

-

... More
Supply and fixing in repairs PCB for four way casette/hiwall type indoor units of VRV Unit including testing complete all as specified and directed.

3

-

-

... More
Supply and fix in repairs Drain Pump for four way casette/hiwall type indoor units of VRV Unit including testing complete all as specified and directed.

2

-

-

... More
Supply and fixing in repairs Blower motor for four way casette/hiwall type indoor units of VRV Unit including testing complete all as specified and directed.

3

-

-

... More
Supply and fixing in repairs Linear expansion Valve for four way casette/hi-wall type indoor units of VRV Unit including testing complete all as specified and directed.

2

-

-

... More
Supply and fixing in repairs Remote Controller for four way casette/hi-wall type indoor units of VRV Unit including testing complete all as specified and directed.

3

-

-

... More
Supply and fixing in repairs Adressing Board for four way casette/hi-wall type indoor units of VRV Unit including testing complete all as specified and directed.

3

-

-

... More
Supply and fixing in repairs copper tube Cooling Coil suitable for four way casette/hi-wall type indoor units not less tha 4 TR of VRV Unit including testing complete all as specified and directed.

2

-

-

... More
Supply and fixing in repairs Modular type 100% all Inverter Variable Refrigerant Flow Outdoor unit of Daikin as per existing of capacity 16HP comprising of Hermetically sealed INVERTER Variable Speed Scroll compressors with control wiring. The unit shall comprise of high efficiency, low noise condenser fan with guard and motor, heat exchanger and coated fins for increased durability. The casing shall be powder coated and the unit shall be provided with liquid line strainer, catch all drier, thermostats etc. suitable for interconnecting with any type of indoor units with cordless remote controller. The ODU & IDU shall be integrated with special control wiring system with the central monitoring control. The unit shall be factory wired and tested before despatch. The operating refrigerant shall be R410A only.The unit shall be BMS compatible with MODBUS protocol. Outdoor should give 100% Capacity at 43 Deg C Ambient Temperature. The COP of the Outdoor units shall be more than 3.6 at design conditions complete all as specified and as directed. Note : The cost of dismantling existing outdoor unit is deemed to included in the quoted rate.

3

-

-

... More
Supply and fixing in repairs solenoid valve for four way Cassette/Hi-wall type indoor units of minimum 4 TR of VRF including testing complete all as specified and directed by Engr-in-Charge.

5

-

-

... More
Supply and fixing in repairs various type of sensors for four way Cassette/Hi-wall type indoor/outdoor units of VRF Unit including testing complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
Supply and fixing in repairs unserviceable / worn-out 'V' Belt of AHU's as per existing.

30

-

-

... More
Supply and fixing in repairs unserviceable / worn-out rubber coupling suitable for compressor shaft and motor shaft as per existing. complete all as specified .

12

-

-

... More
Supply, install, test & commissioning compressor sealed reciprocating/rotory type as per existing make suitable for window type AC 1.5 Ton capacity including providing copper tubing, electrical connection, making joints leakproof including taking out old compressor complete all as specified and directed.

25

-

-

... More
-Ditto- all as per item No 74.00 above but of 2.0 Ton capacity

18

-

-

... More
-Ditto- all as per item No 74.00 above but of Split type AC 1.5 ton capacity

45

-

-

... More
-Ditto- all as per item No 74.00 above but of Split type AC 2.0 ton capacity

35

-

-

... More
-Ditto- all as per item No 74.00 above but of Refrigerator 100/165/180/210 Liters Capacity.

3

-

-

... More
-Ditto- all as per item No 74.00 above but of Refrigerator 260/280/310/350 Liters Capacity.

1

-

-

... More
-Ditto- all as per item No 74.00 above but of Water coolers 40 / 60 /80 Liters capacity

15

-

-

... More
-Ditto- all as per item No 74.00 above but of Water coolers 120/150/170 Liters capacity

10

-

-

... More
-Ditto- all as per item No 74.00 above but of deep freezers of capacity 310ltrs/410Ltrs. Capacity

3

-

-

... More
Taking down carefully split type AC of capacity 1.5 / 2.0 ton & refixing on new location complete with pre fabricated brackets/ frame work as required complete & making good existing surface with out any damage to outdoor & indoor unit complete all as specified and directed.

15

-

-

... More
Supply and fixing in repairs fan motor suitable for window/Split type AC of capacity 1.0 / 1.5 / 2.0 Ton of existing make including connecting up and testing complete all as specified and directed.

50

-

-

... More
S & F in repairs fan motor suitable for water cooler of any capacity and existing make and testing complete all as specified and directed.

15

-

-

... More
S & F in repairs fan blade suitable for water cooler of any capacity and existing make and testing complete all as specified and directed.

15

-

-

... More
Supply & fixing in repairs blower drum suitable for window type Air conditioner of 1.0 Ton / 1.5 Ton / 2.0 Ton capacity complete all as specified and directed..

15

-

-

... More
Supply & fixing in repairs front cover grill suitable for window type AC upto 2.0 TR capacity.

25

-

-

... More
Supply & fixing in repairs starting capacitor 60 - 80 , AC 220 V , 50 Hz

200

-

-

... More
Supply & fixing in repairs starting capacitor 80-100 AC 220 V , 50 Hz

200

-

-

... More
Supply & fixing in repairs starting capacitor 100 -120 AC 220 V , 50 Hz

120

-

-

... More
Supply & fixing in repairs running capacitor 25 MFD AC 220 V , 50 Hz

125

-

-

... More
Supply & fixing in repairs running capacitor 36 MFD AC 220 V , 50 Hz

180

-

-

... More
Supply & fixing in repairs running capacitor 45 AC 220 V , 50 Hz MFD

200

-

-

... More
Supply & fixing in repairs selector switch push button type for window type AC a upto 2.0 Ton capacity complete all as specified and directed.

50

-

-

... More
Supply & fixing in repairs selector switch rotary type for window type AC a upto 2.0 Ton capacity complete all as specified and directed.

20

-

-

... More
Supply & fixing in repairs thermostat switch for window type AC of capacity upto 2.0 TR capacity complete all as specified and directed.

60

-

-

... More
Supply & fixing in replcirs thermostat switch for split type AC of capacity upto 2.0 TR capacity complete all as specified and directed.

80

-

-

... More
Supply & fixing in repairs thermostat switch for Refrigerator of any capacity complete all as specified and directed.

10

-

-

... More
S & F in repairs thermostat switch for Water Cooler of any capacity complete all as specified and directed.

15

-

-

... More
Supply & fixing in repairs new over load relay suitable for Window/Split type AC upto 2 TR capacity complete all as specified and directed. .

100

-

-

... More
Supply & fixing in repairs over load relay suitable for water cooler of any capacity complete all as specified and directed.

35

-

-

... More
Supply & fixing in repairs over load relay suitable for Refrigerator of any capacity complete all as specified and directed.

15

-

-

... More
S & F in repairs Float valve 15 mm suitable for Water cooler of any capacity complete all as specified and directed.

30

-

-

... More
Supply & fixing copper tubing of required size for suction line and for liquid discharge line duly insulated with suitable insulation material and clamping, jointing including making hole in wall for passing through and making good to the disturbed surface complete all as specified and directed.

425

-

-

... More
Supply and lay cable PVC insulated 4 core 4 Sq mm with copper conductor cable suitable for indoor unit to outdoor unit complete all as specified and directed.

410

-

-

... More
Supply and lay PVC pipe 20 mm dia heavy duty for drain out condensing water of split AC including cutting of floor / opening of hole in wall and making good after laying of pipe to match the existing surface complete all as specified and directed.

250

-

-

... More
S & F in repairs push cock of chromium plated of size 15 mm dia suitable for water cooler of any capacity complete all as specified and directed.

45

-

-

... More
S & F in repairs PVC connecting pipe with brass nuts, bolts and washers at both ends of length not exc 60 cm for connection of water coolers complete all as specified and directed.

30

-

-

... More
S & F in repairs GI water tray 3 mm thick for window type AC any capacity with out let system connection provided with PVC pipe of 20 mm dia up to 3 meter length connecting to drain pipe complete all as specified and directed..

30

-

-

... More
S & F in repairs 25mm bore PVC drain pipe fixed with necessary saddles complete all as specified and directed.

100

-

-

... More
S & F in repairs sheet metal enclosure with 2 pin and earth plug and socket complete with single pole MCB of 20 Amps 'C' curve complete all as specified and directed.

70

-

-

... More
S & F in repairs copper tube condensor of 1.5 ton window type AC including copper tube coil with fins and connecting inlet and outlet connection of copper pipe by brazing and providing flair nu,t bolts, washers and tighting by teflon seal tape complete all as specified and directed.

25

-

-

... More
-Ditto- all as per item 113.00 above but for 2.0 ton window type AC.

18

-

-

... More
-Ditto- all as per item 113.00 above but for 1.5 ton Split type AC .

35

-

-

... More
-Ditto- all as per item 113.00 above but for 2.0 ton Split type AC .

25

-

-

... More
S & F in repairs circuit boards (PCB) suitable for window type AC 1.5 ton / 2.0 Ton capacity and connecting with system including remote control hand set and testing complete all as specified and directed

40

-

-

... More
-Ditto- all as per item 117.00 above but for 1.5 Ton / 2.0 Ton Split type AC .

35

-

-

... More
S & F in repairs blower fan motor capacitor 4 MFD , AC 220 V, 50 Hz complete all as specified and directed.

120

-

-

... More
S & F in repairs blower fan motor capacitor 6 MFD AC 220 V, 50 Hz complete all as specified and directed.

150

-

-

... More
S & F in repairs Air filter for window/spilt type AC upto 2 TR capacity complete all as specified and directed.

30

-

-

... More
S & F in repairs factory made outer cover for window type Air conditioner of any capacity and size made out of GI sheet of 20SWG complete all as specified and directed.

30

-

-

... More
M&L for taking out unserviceable PCB from AC unit, transporting to OEM workshop for repair and installation with the unit after repair including testing and commissioning complete all as specified and directed by Engr-in-Charge.

40

-

-

... More
S & F in repairs remote control handset suitable for 1.5/2.0 Ton capacity split type AC complete all as specified and directed.

30

-

-

... More
Supply and fixing in repairs multipurpose door lock with duplicate key of refrigerator of any make & capacity complete all as specified and directed.

10

-

-

... More
Taking out old unserviceable cooling coil of window/split type AC of any capacity and any make cutting inlet/outlet connecting copper pipe and providing new copper tube cooling coil with fins and connecting inlet, outlet copper pipe by brazing and replacement of nut , bolts and washers and joints sealed with teflon pape complete all as specified and directed.

15

-

-

... More
Supply & fixing in repairs factory made MS stand, powder coated suitable for mounting condensing unit and outdoor door unit of split type AC including nut, bolts & washers complete all as specified and directed.

35

-

-

... More
Supply and fixing in repairs power contactor AC 3 type ,220 v, 50 Hz suitable for split type AC of 1.5 / 2 TR capacity complete all as specified and directed.

44

-

-

... More
Supply and fixing in repairs sunction & liquid line valve of size (5/8"&1/4")/(5/8"&3/8") suitable for split type AC complete all as specified and directed.

50

-

-

... More
Supply and fixing in repairs indoor unit of tower AC 2 TR capacity, single phase, 220 Volts, 50 Hz having 5 star rating complete with all accessories such as installation plate with screw, blower motor, swing motor, filter and PCB etc duly prewired including reconnecting of existing refrigerant piping, electrical connections, drain pipe, copper tube cooling coil etc complete all as specified and directed.

2

-

-

... More
Supply and fixing in repairs outdoor unit of tower type AC 2 TR cap having 5 star rating complete with copper tube condensor coil , twin rotary compressor, single phase unit 220V-240V, 50 Hz duly prewired including reconnecting of existing refrigerant piping, electrical connection, etc complete all as specified and directed. Note : Rate of supporting brackets for outdoor unit is deemed to include in the quoted rate.

2

-

-

... More
Supply and fixing in repairs indoor unit of split type AC 1.5TR capacity having 5 star rating complete with copper tube cooling coil and all accessories such as installation plate with screw, blower motor, swing notor, filter and PCB etc duly prewired including reconnecting of existing refrigerant piping, electrical connections, drain pipe etc complete all as specified and directed.

8

-

-

... More
Supply and fixing in repairs outdoor unit of split type AC 1.5TR cap having 5 star rating complete with all accessories such as hermetically sealed compressor, condenser unit,capacitor, relay, fan motor etc duly prewired including reconnecting of existing refrigerant piping, electrical connection,etc complete all as specified and directed.

8

-

-

... More
Supply and fixing in repairs indoor unit of split type AC 2 TR capacity having 5 star rating complete with copper tube cooling coil and all accessories such as installation plate with screw, blower motor, swing motor, filter and PCB etc duly prewired including reconnecting of existing refrigerant piping, electrical connections, drain pipe etc complete all as specified and directed.

6

-

-

... More
Supply and fixing in repairs outdoor unit of split type AC 2 TR cap having 5 star rating complete with copper tube condensor all accessories such as hermetically sealed compressor, condenser unit,capacitor, relay, fan motor etc duly prewired including reconnecting of existing refrigerant piping, electrical connection,etc complete all as specified and directed.

6

-

-

... More
Supply and fixing in repairs 2KW AC, 220 V, 50 Hz Heater strip for cold storage plant.

10

-

-

... More
M & L for Pumping down refrigerent from cold room plant, leak testing of plant by charging of Nitrogen gas in to entire plant and monitoring for 24 hrs to find the leakages and rectification of leak by brazing of copper rod & replacement of gasket packing including vacumizing of the plant by vaccum pump and keep up 24hrs. for testing including rectification of leakage if any finally recharging of gas to the plant to maintain the standard pressure and test for following cold room installations.

-

-

-

... More
Cold room refrigerant unit 5TR AC,415 V, 50 Hz Capacity

2

-

-

... More
Cold room refrigerant unit 3TR AC,415 V, 50 Hz Capacity

2

-

-

... More
Cool room refrigerant unit 2TR AC,220 V, 50 Hz Capacity

2

-

-

... More
Supply, install and testing sealed compressor of following capacity refrigerant unit including connecting pipe line, brazing and electirc connection for cold storage including removing old unserviceable compressor from the unit after disconnecting electrical wiring and piping connection with nuts and bolts at B.V yard,colaba complete all as specified and directed.

-

-

-

... More
Refrigerant unit of Compressor 5TR, AC,415 V, 50 Hz Capacity

2

-

-

... More
Refrigerant unit of Compressor 3TR AC,415 V, 50 Hz Capacity

2

-

-

... More
Refrigerant unit of Compressor 2TR AC,220 V, 50 Hz Capacity

2

-

-

... More
M & L for removing worn out control wiring and providing/rewiring with suitable size copper conductor cable including replacing copper lugs starter to compressor motor, fan motor timer HP/LP cut , thermostat complete interlock wiring, checking the complete function of timer, heaters, relays, HP/LP cut outs, thermostat cut out and inter lock wiring system, testing on load and all wiring shall be mounted on GI hot drip cable tray of size 200mm x 50mm complete all as specified and directed for cold storage of following capacity:-

-

-

-

... More
Refrigerant unit of 5TR Capacity

2

-

-

... More
Refrigerant unit of 3TR Capacity

2

-

-

... More
Refrigerant unit of 2TR Capacity

2

-

-

... More
Material and Labour for attending complaints of finding leakages in pipeline of any length, type & size and rectification of leakages and applying run lead joint/spigot & socket joint/flange joints/D joint etc including provision of jointing material such as lead/flanges /clamps/jute/ rubber gaskets/nuts/ bolts/ washers /grease/socket etc, and testing of line after leakage rectification complete all as specified and directed. Note : (i) The cost of labour for excavation in any type of strata, cutting of RCC/PCC surfaces/ road, returning filling, fixing of joint, T&P and making good to the existing is included in the rate quoated by the contractor. (ii) Testing shall be carried out in the presence of Engineer-in-charge to the entire satisfaction . (iii) The cost of joints, fittings, nut, bolts, clamps, flange, rubber packing, welding, D joint of any size etc shall be included in quoted rate (iv) Repair to the leakage after informing complaint by concerned JE E/M or Engr-in-Charge within 24 hours. In case of failure noticed more than 24 hrs recovery shall be effected @ Rs.500/- per hour beyond 24 hrs.

35

-

-

... More
M&L for comprehensive maintenance of Pump motor of any capacity and type, connected LT Panels, valves and water pipeline of any type and size installed at various locations including detection of fault and its rectification, cleaning, inspecting, replacement of defective parts after electrical disconnecting and taking down pump motor, repair/replacement of defective parts and re-connecting duly alligned as per existing, testing of equipments complete all as specified and directed by Engr-in-Charge for the following locations :- (a) INS AGNIBAHU (b) INS ANGRE Note : (i) Spare parts shall be measured and paid separately under respective items. (ii) Cost of manpower (01 FGM and 01 helper for servicing and replacement of spare parts on daily basis excluding sunday shall deemed to be included in the quoted rate. (iii) Minor spares such as gland packing, grease, oil, nut, bolts, washer, rubber packing, couplings etc is deemed to included in quoted rates. (iv) The cost of transportation of pump motor of any capacity and size from site of work to the workshop and back to site if required is deemed to be included in quoted rate.

6

-

-

... More
Disconnecting and dismantling of diesel engine driven pump of any capacity, make and model, servicing, oiling, checking and repair of FIP, replacement of filters, replacement of vibration pads as per OEM recommendation, overhauling etc including replacement of defective parts, testing & commissioning complete all as specified and directed by Engineer-in-charge. Note : Cost of transportation from site to the workshop and back if required is deemed to be included in quoted rate.

8

-

-

... More
M & L for construction of brick masonry valve chamber of size 1200mm x 1200mm x 1200mm (internal dimension) (above GL 0.30 mtr) comprising of 15cm thick PCC 1:4:8 type D-2 foundation over 15cm thick hardcore of broken stone, 23cm thick brick walls built in cement and sand mortar 1:4, 15mm thick internal and external plaster, top of floor 15mm thick in cement and sand mortar 1:3 finished even and smooth without using extra cement, 5 mm thick MS plate cover over complete chamber fixed on 50mm x 50mm x 6mm MS angle frame welded to MS hold fasts embeded in 50mm thick 1:2:4 type B-1 coping, having rectangular, hinged, opening of size 150 x 100mm with locking arrangements and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including necessary excavation and earth work in any type of soil and demolition of existing valve chamber and removing debries outside MD land complete all as specified. Note: The place of disposal shall be find out by the contractor.

7

-

-

... More
Disconnecting all electrical connections of pumpset and dismantling horizontal / vertical split casing pump / Submersible pump of any make/model, dismantling and taking out pump shaft assembly for replacement of pump bearing DE or NDE, pump gasket including servicing, oiling and greasing the pumpset and assembling after replacment of defective parts and connecting to coupling, testing & commissioning complete all as specified and directed for following sizes / capacities of pump :-

-

-

-

... More
Bearing suitable for pump coupled with 100 HP motor as per existing make.

2

-

-

... More
Bearing suitable for pump coupled with 75 HP motor as per existing make.

3

-

-

... More
Bearing suitable for pump coupled with 60 HP motor as per existing make.

2

-

-

... More
Bearing suitable for pump coupled with 50/40 HP motor as per existing make.

2

-

-

... More
Bearing suitable for pump coupled with 15 HP" motor as per existing make.

5

-

-

... More
Bearing suitable for pump coupled with 7.5/5 HP motor as per existing make.

4

-

-

... More
Bearing suitable for pump coupled with 30 HP motor as per existing make.

5

-

-

... More
S&F in repair DE/NDE bearing of electric driven motor coupled wih pump including necessary greasing reassemble the motor, connect, testing and commissioning complete for following capacity motors :-

-

-

-

... More
Bearing suitable for Motor of capacity 125/100 HP as per existing make.

2

-

-

... More
Bearing suitable for Motor of capacity 60/75 HP as per existing make.

3

-

-

... More
Bearing suitable for Motor of capacity 25/30 HP as per existing make.

3

-

-

... More
Bearing suitable for Motor of capacity 7.5/10 HP as per existing make.

3

-

-

... More
S & F in repairs rubber coupling suitable for pump set of capacity upto 50 HP.

4

-

-

... More
S&F in repair pressure gauge 150 mm dia range 0-10 kg/Sqcm , Note : Rate quoted shall deemed to be included for providing adopter/Ferrule/check nut etc required for fixing of pressure guage.

10

-

-

... More
S&F in repair MS coupling suitable for 50 HP pumps

6

-

-

... More
S&F in repair MS coupling suitable for 40 HP pumps

5

-

-

... More
M&L for transporting electric burnt motor to authorised workshop for rewinding strip opening and dismantling complete rotor and stator assemby, cutting; and taking out old burnt copper winding from the stator assembly and cleaning the slots of stator with carbon tetra chloride solution. Material and labour for rewinding complete stator assembly including super enamelled copper winding wire of suitable gauge machine with existing, applying minimum two coats of insulation varnish and keeping the stator assembly in heating chamber to improve insulation value. assembling the motor , transporting back at site, coupled with the pumping sets allingments properly, connecting the LT cables and testing and commissioning complete all as specified and directed by Engr-in-Charge for electric Motors of following capacities :-

-

-

-

... More
125/100 HP capacity

1

-

-

... More
75/60 HP Capacity

2

-

-

... More
40/50 HP Capacity

2

-

-

... More
30/25 HP Capacity

3

-

-

... More
15/20 HP Capacity

2

-

-

... More
10 HP Capacity

2

-

-

... More
5/7.5 HP Capacity

3

-

-

... More
S&F in repairs main contactor suitable for 75/60 HP motor, MNX 95, 3 pole, 415V, 50 Hz .

4

-

-

... More
S&F in repairs main contactor suitable for 40/50 HP motor, MNX 70, 3 pole, 415V, 50 Hz

4

-

-

... More
S&F in repairs over load relay suitable for 100 to 7.5 HP motor , Relay range (35-50A) 415V, 50 Hz complete all as specified.

6

-

-

... More
S&F in repairs MCCB 3 Phase (TP) 200A 50Hz, 35 KA. 415V, 50 Hz in existing panel complete all as specified.

2

-

-

... More
S&F in repairs MCCB 3 Phase (TP) 100A 50Hz, 25 KA, 415V, 50 Hz in existing panel complete all as specified.

2

-

-

... More
S&F in repairs MCCB 3 Phase (TP) 63A 50Hz, 25 KA, 415V, 50 Hz in existing panel complete all as specified.

2

-

-

... More
S & F in repairs shaft sleeves Suitable for 40/30 HP capacity pump sets of existing make

2

-

-

... More
S & F in repairs shaft sleeves Suitable for 15/ 20 HP capacity pump sets of existing make

2

-

-

... More
S & F in repairs shaft sleeves Suitable for 10 HP capacity pump sets of existing make

2

-

-

... More
S & F in repairs impeller suitable for 40 HP capacity pump set of existing make

2

-

-

... More
S & F in repairs impeller suitable for 10 HP capacity pump set of existing make

2

-

-

... More
S & F in repairs impeller suitable for 30 HP capacity pump set of existing make

2

-

-

... More
S & F in repairs impeller suitable for 15 HP capacity pump set of existing make

3

-

-

... More
Supply and fix in repair direct on line (DOL) starter 3 phase 415 Volts suitable for pumpset of 05 HP capacity.

3

-

-

... More
Material and labour for repairing, metal filling, turning and grinding of pumpset shaft on machine for 40 HP capacity pump set complete all as specified and directed.

2

-

-

... More
Material and labour for repairing, metal filling, turning and grinding of pumpset shaft on machine for 30 HP capacity pump set complete all as specified and directed.

2

-

-

... More
Material and labour for repairing, metal filling, turning and grinding of pumpset shaft on machine for 15 HP capacity pump set complete all as specified and directed.

2

-

-

... More
Material and labour for repairing, metal filling, turning and grinding of pumpset shaft on machine for 20 HP capacity pump set complete all as specified and directed.

3

-

-

... More
Material and labour for repairing, metal filling, turning and grinding of pumpset shaft on machine for 1.5/ 10 HP capacity pump set complete all as specified and directed.

5

-

-

... More
S & F in repairs gland packing suitable for pump set 125 HP to 10 HP capacity including cleaning complete all as specified.

25

-

-

... More
Supply and fix in repairs Star Delta Starter suitable for 40 HP Motor, 415V, 50 HZ complete all as specified.

2

-

-

... More
Supply and fix in repairs Star Delta Starter suitable for 30 HP Motor, 415V, 50 HZ complete all as specified.

2

-

-

... More
Supply and fix in repairs Star Delta Starter suitable for 20 HP Motor, 415V, 50 HZ complete all as specified.

2

-

-

... More
Supply and fix in repairs Star Delta Starter suitable for 15 HP Motor, 415V, 50 HZ complete all as specified.

3

-

-

... More
M & L for taking down 100/75 HP capacity centrifugal pump sets, dismantling, servicing/overhauling , greasing and replacement of worn out parts reassembling the pump set and testing on complete of following capacity pumps installed at various water supply installations complete all as specified. Note- New parts shall be measured and paid separately under the relevant items of Sch `A' :-

4

-

-

... More
-Ditto- all as per item 178.00 above but 50/40 HP capacity centrifugal pump sets

4

-

-

... More
-Ditto- all as per item 178.00 above but 30/20 HP capacity centrifugal pump sets

4

-

-

... More
-Ditto- all as per item 178.00 above but 15/10/7.5/5 HP capacity centrifugal pump sets

4

-

-

... More
M & L for run lead joint with pig lead for 300mm bore CI spigot and socket pipes and fittings including pumping out accumulated water from the leak site and necessary excavation and earth work in any type of soil to repair the joints including taking out carefully old lead joint of following size pipes

2

-

-

... More
-Ditto- all as per item 182.00 above but 200 mm bore pipe

5

-

-

... More
-Ditto- all as per item 182.00 above but 150 mm bore pipe

10

-

-

... More
-Ditto- all as per item 182.00 above but 100 mm bore pipe

10

-

-

... More
S&F in repairs 300mm bore heavy duty sluice valves flanged end, cast iron body, heavy duty flanged and drilled and non rising type brass spindle with nut, long body, class PN 1.6, conforing to IS 14846 of 2000 for following sizes including all flange joint with rubber or fiber board, bolts, nuts and washers complete including pumping out accumulated water complete all as specified and directed.

1

-

-

... More
'-Ditto- all as per item 186.00 above but 250 mm bore

2

-

-

... More
'-Ditto- all as per item 186.00 above but 200 mm bore

2

-

-

... More
'-Ditto- all as per item 186.00 above but 150 mm bore

4

-

-

... More
'-Ditto- all as per item 186.00 above but 100 mm bore

5

-

-

... More
'-Ditto- all as per item 186.00 above but 80 mm bore

4

-

-

... More
S&F 15 mm bore GI tubing medium grade with all fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc fixed to walls and ceilings with suitable size GI clamps or laid in trenches including taking down old GI tubing including fittings complete all as specified.

120

-

-

... More
'-Ditto- all as per item 192.00 above but 20 mm bore

155

-

-

... More
'-Ditto- all as per item 192.00 above but 25 mm bore

200

-

-

... More
'-Ditto- all as per item 192.00 above but 40 mm bore

180

-

-

... More
'-Ditto- all as per item 192.00 above but 50 mm bore

200

-

-

... More
'-Ditto- all as per item 192.00 above but 80 mm bore

180

-

-

... More
'-Ditto- all as per item 192.00 above but 100 mm bore

200

-

-

... More
Supply and fix in repairs 40mm bore gun metal gate valve with iron wheel head screwed both ends for iron pipe including fittings i.e. union, socket etc complete all as specified .

50

-

-

... More
'-Ditto- all as per item 199.00 above but 50 mm bore

50

-

-

... More
'-Ditto- all as per item 199.00 above but 25 mm bore

50

-

-

... More
'-Ditto- all as per item 199.00 above but 20 mm bore

60

-

-

... More
Supply and fixing in repairs 300mm bore cast iron pipes with flange joint both ends centrifugally cast heavy grade class A in any length laid in trenches complete all as specified.

20

-

-

... More
'-Ditto- all as per item 203.00 above but 200mm bore

50

-

-

... More
-Ditto- all as per item 203.00 above but 150mm bore

100

-

-

... More
-Ditto- all as per item 203.00 above but 100mm bore

90

-

-

... More
-Ditto- all as per item 203.00 above but 80mm bore

45

-

-

... More
S&F in repair MS plate cover 5mm thick for valve chamber,under ground sump/ over head tank, including necessary fabrication work with hinges, handle and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified.

200

-

-

... More
S&F in repairs angle iron frame made out of 50 x 50 x 6 mm angle for valve chamber, over head tank, UG sump including necessary fabrication work including hold fasts embedded in PCC 1:2: 4 type B1 complete all as specified

300

-

-

... More
Supply, installation and testing DIGITAL WATER LEVEL INDICATOR DEVICE, operating on Single Phase supply, direct display in 150 mm size digit display system which must show water in meter/centimeter or gallon of water level of SUMPS/OVER HEAD TANK ensuring alarm while water fall or rise at predetermined limit with 1 minute auto off alarm complete with following details (a) The entire unit must operate through a compact electronic circuit which must ensure reliable operation at 230 volts+/- 5% with reliable in digit display & alarm at low & high level of SUMPS/OVER HEAD TANK. (b) The circuit must be housed in MS CRC Sheet box of suitable size with nylon moulded connection strips. The level system must resistance trasducer which unaffected by corrosion and other contacts available in water. The product must be controlled by micro switch (should not be sensor system). (c) The whole unit must electronically controlled and the upper level and lower level indicator must be highly sensitive MICRO SWITCH. The complete unit must be fitted in MSCRC sheet box powder coated and be installed at PUMP HOUSE . (d) The required flexible copper conductor cable of 0.5/1.5 sqmm, 3 core size from SUMPS/OVER HEAD TANK to PUMP HOUSE laid through and including GI pipe 15mm bore shall be provided for connection of both units and quoted rate includes the same. Note: The cost of GI Conduit for protection of copper cable including taking down existing unserviceable water level indicator complete shall be included in quoted rate.

2

-

-

... More
Material and labour for preperation of old painted steel surface of any description , not otherwise described and applying two coats with synthetic enamel paint over a coat with red oxide zinc chromeprimer complete all as specified and directed.

600

-

-

... More
Excavating in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation/ laying of pipe and getting out in hard / dense soil complete all as specified.

120

-

-

... More
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm deep as in soil complete all as specified .

95

-

-

... More
Removing surplus excavated soil to a distance not exceeding 50 m and deposited where directed complete all as specified.

25

-

-

... More
S&F in repairs rotational moulded polyethylene water storage tank 5000 Ltr capacity, (cylindrical vertical with closed top), three layer, white colour including all connections for inlet, outlet, over flow and wash out etc hoisted and fixed in position all as specified in SSR Part-I including approved PVC cover with locking arrangement complete all as specified.

2

-

-

... More
-Ditto- all as per item 215.00 above but 3000 Ltr capacity

2

-

-

... More
-Ditto- all as per item 215.00 above but 2000 Ltr capacity

10

-

-

... More
-Ditto- all as per item 215.00 above but 1000 Ltr Capacity

10

-

-

... More
-Ditto- all as per item 215.00 above but 10000 Ltr Capacity

1

-

-

... More
Supply and fix in repairs LT 1100 volts grade submersible cable, flat 6 Sqm 3 core, PVC insulated and seathed copper screen protected with multi stranded copper conductor complete all as specified and directed by Engr-in-charge.

150

-

-

... More
Supply, installing, testing and commissioning, factory made and tested ( CPRI approved and certified), LT feeder pillar box (KIOSK) of appropriate dimensions (as per Indian Electricity rules) to accommodate following components, indoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bars 500 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA sheet and 40 x 40 x 6mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front & rear opening type, with aprons for cable entry, with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) lock with 2 keys, internal wiring with PVC insulated, multistranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm. The scope of work includes the following:- COMPONENTS Incoming :(a) Copper bus bar of rating 800 Amps for four pole including PVC heat shrink sleeves (RYB & N ) : 01 Set (b) MCCB four pole 630 Amp ('C' Curve), 415 Volts, rupturing capacity- 16 kA, 415 Volts microprocessor control type- 01 No Outgoint :- (a) MCCB 4 pole 250 Amp ('C' Curve), rupturing capacity- 16 kA conforming thermal magnetic release and adjustable over load setting 415 V AC , 50 Hz complete - 02 Nos (b) MCCB 3 pole 160 Amp ('C' Curve), rupturing capacity- 16 kA conforming thermal magnetic release and adjustable over load setting 415 V AC , 50 Hz complete - 02 Nos (c) On load change over 315 A Voltmeter - 01 No (c) Ammeter- 01 No Note :Necessary approval of drawings of LT feeder pillars to be taken from GE before placing order by the contractor.

1

-

-

... More
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 core. laid in trench/ duct / along pole/wall etc including making connection complete all as directed. Note : i). The cost of thimbles/lugs and cable gland etc is including in quoted rate and no extra payment will be made for it.

170

-

-

... More
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core. laid in trench/ duct / along pole/wall etc including making connection complete all as directed. Note : i) The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.

180

-

-

... More
Attending complaints to all kinds of pump motors by qualified mechanic to check and test DOL/star-delta starter connections including settings of relay and timer, NO & NC contacts, main power connections, fixing of cable joints,fixing gland packing of approprate size to the pump motors, rectifying pump leakages by replacing flange, rubber packing and nut bolts of existing size and cleaning of pump motors to confirm the satisfactory running with replacement of following items. The cost of minor spares such as lugs of all size, wires, nut, bolts, washer, Flanges, rubber packing, gland packing, cable joints, motor fan etc are included in quoted rate by contractor. Note: Repair to defects after informing within 24 hours, in case of failure noticed more than 24 hrs recovery shall be effected @ Rs.500/- per hour beyond 24 hrs.

22

-

-

... More
Supply and fix in repairs 80mm bore Non return valve cast iron flanged both end connecting in line with nut bolts, rubber packing etc complete all as specified and directed by Engr- in charge.

2

-

-

... More
Supply and fix in repairs 100mm bore Non return valve cast iron flanged both end connecting in line with nut bolts, rubber packing etc complete all as specified and directed by Engr- in charge.

2

-

-

... More
Supply and fix in repairs 150mm bore Non return valve cast iron flanged both end connecting in line with nut bolts, rubber packing etc complete all as specified and directed by Engr- in charge.

2

-

-

... More
Supply and fix Brass foot valve heavy duty 50 mm/65 mm dia brass with all accessories complete all as specified and directed by Engr- in charge.

2

-

-

... More
Supply and fix Brass foot valve heavy duty 65 mm upto 80 mm dia brass with all accessories complete all as specified and directed by Engr- in charge.

4

-

-

... More
Supply and fix Brass foot valve heavy duty 100 mm dia brass with all accessories complete all as specified and directed by Engr- in charge.

4

-

-

... More
Supply and fix Brass foot valve heavy duty 150 mm dia brass with all accessories complete all as specified and directed by Engr- in charge.

5

-

-

... More
Supply and fix 50 mm dia ball brass high pressure with polythene float and fly nut of screwed to iron or brass ferrule complete all as specified and directed by Engr- in charge.

35

-

-

... More
Supply and fix 40 mm dia ball brass high pressure with polythene float and fly nut of screwed to iron or brass ferrule complete all as specified and directed by Engr- in charge.

40

-

-

... More
Supply and fix 25 mm dia ball brass high pressure with polythene float and fly nut of screwed to iron or brass ferrule complete all as specified and directed by Engr- in charge.

132

-

-

... More
Supply and fix 20 mm dia ball brass high pressure with polythene float and fly nut of screwed to iron or brass ferrule complete all as specified and directed by Engr- in charge.

150

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.