Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date3 Jul 2024
Closing Date3 Sep 2024
Tender Amount₹ 40,00,000
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_663571_1Bid Award Id
ViewTender No
8834/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Ditto all as per item No 1 above but 3.5 Core 150 Sqmm
50
-
-
Ditto all as per item No 1 above but 3.5 Core 120 Sqmm
40
-
-
Ditto all as per item No 1 above but 3.5 Core 95 Sqmm
60
-
-
Ditto all as per item No 1 above but 3.5 Core 70 Sqmm
80
-
-
Ditto all as per item No 1 above but 3.5 Core 50 Sqmm
100
-
-
Ditto all as per item No 1 above but 3.5 Core 35 Sqmm
120
-
-
Ditto all as per item No 1 above but 3.5 Core 25 Sqmm
130
-
-
Ditto all as per item No 1 above but 4 Core 16 Sqmm
100
-
-
Ditto all as per item No 1 above but 4 Core 10 Sqmm
110
-
-
Supply and laying in replacement including testing and commissionnig of LT UG Cables 1100 volts grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip armoured with multi stranded aluminum conductor, ISI marked, heavy duty including disconnection from LT Panel/Fedder Pillar/Pole etc and reconnection after laying work to same LT Panel/Feeder Pillar /Pole according to existing system with suitable size of AL Lugs, nut-bolts & washers etc including cables laid in trenches/ducts/under plinth floors/ passing through pipes etc or fixed on any type of wall with suitable size of GI saddles etc complete of size 3.5 Core 300 Sqmm. Note - Excavation / earthwork, cable protection covers & sand cushioning will be measured and paid separately under respective item of sch A.
150
-
-
Ditto all as per item No 13 above but 3.5 Core 240 Sqmm
100
-
-
Ditto all as per item No 13 above but3.5 Core 185 Sqmm
75
-
-
Ditto all as per item No 13 above but 3.5 Core 150 Sqmm
350
-
-
Ditto all as per item No 13 above but 3.5 Core 120 Sqmm
350
-
-
Ditto all as per item No 13 above but 3.5 Core 95 Sqmm
400
-
-
Ditto all as per item No 13 above but 3.5 Core 70 Sqmm
300
-
-
Ditto all as per item No 13 above but 3.5 Core 50 Sqmm
400
-
-
Ditto all as per item No 13 above but 3.5 Core 35 Sqmm
400
-
-
Ditto all as per item No 13 above but 3.5 Core 25 Sqmm
500
-
-
Ditto all as per item No 13 above but 4 Core 16 Sqmm
400
-
-
Ditto all as per item No 13 above but 4 Core 10 Sqmm
450
-
-
Ditto all as per item No 13 above but 4 Core 6 Sqmm
250
-
-
Excavation in trenches, n.exc 1.5m wide and n. exc 1.5 m depth and getting out for foundation of pole, stay, laying of cable and pipe etc in Hard/Dense soil complete all as specified and as directed.
602.44
-
-
Ditto all as per item No 26 above but Soft / Disintegrated Rock
258.19
-
-
Returning and filling, including spreading levelling and well ramming in layers n exc 25 cm complete all as specified and directed.
440.18
-
-
Removing excavated material a distance n. exc 50 m & depositing where directed at a level n. exc 1.5 m above the starting point complete all as specified and directed.
420.45
-
-
M&L for dry crush sand cushioing to under ground cable in trenches incl spreading, leveling and hand punning complete all as specified and directed. Note : For measurement purpose punned thickness shall be considered.
288.48
-
-
Supply and laying in replacement of burnt clay fly ash building modular bricks, designation 75 (Kg/Sqcm), laid in right angle along the cable for protection of cable, complete all as specified and directed.
30.97
-
-
Supply & Laying in replacement of half round un-reinforced concrete pipe, inner dia 150 mm and outer dia 200mm, half round for bottom and half round for top and before laying excavated area shall be leveled, complete all as specified and directed. Note : 01 Half round top and 01 half round bottom together will be considered as one running meter. Make as per sample approved by Engr-In-Charge complete all as specified and directed..
688.5
-
-
Supply and laying in replacement G.I pipe light grade with all fittings required for protection of under ground cable of size 50 mm dia complete all as specified and as directed.
62
-
-
Ditto all as per item No 33 above but 80 mm dia
48
-
-
Ditto all as per item No 33 above but 100 mm dia
60
-
-
M&L for road cutting through existing bituminous road as required for laying pipe/cable etc and make good with and including earthwork and necessary excavation, complete material required to match with the existing one or with PCC (1:2:4) type B1 complete all as specified and as directed
70
-
-
M & L for Straight Through Jointing Kit Heat Shrink type suitable for 1.1 KV LT XLPE armoured aluminium stranded conductor Cable Outdoor type complete with jointing material and accessories including taking shut down and opening the cable from both side of Bus Bar Panel/LT Panel/MCCB/ACB etc and re-terminated the same cable in the same Bus Bar Panel/LT Panel/MCCB/ACB etc according to existing system after completion of jointing work complete all as specified and directed of following sizes :- 3.5 Core 300 Sqmm
2
-
-
Ditto all as per item No 37 above but 3.5 Core 240 Sqmm
2
-
-
Ditto all as per item No 37 above but 3.5 Core 185 Sqmm
1
-
-
Ditto all as per item No 37 above but 3.5 Core 150 Sqmm
3
-
-
Ditto all as per item No 37 above but 3.5 Core 120 Sqmm
4
-
-
Ditto all as per item No 37 above but 3.5 Core 95 Sqmm
4
-
-
Ditto all as per item No 37 above but 3.5 Core 70 Sqmm
5
-
-
Ditto all as per item No 37 above but 3.5 Core 50 Sqmm
5
-
-
Ditto all as per item No 37 above but 3.5 Core 35 Sqmm
4
-
-
Ditto all as per item No 37 above but 3.5 Core 25 Sqmm
6
-
-
Ditto all as per item No 37 above but 4 Core 16 Sqmm
5
-
-
Ditto all as per item No 37 above but 4 Core 10 Sqmm
5
-
-
M &L in replacement of earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level in any type of soil strata, connected to galvanized earth lead wire of 4 mm dia by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 3 of MES schedule 1991 Part – I connected to LT Poles /DBs etc. as required including necessary excavation and earth work, concrete pit chamber, cover of PCC 1:2:4 type B1 including lifting handle and Earth lead and 20mm Dia GI watering pipe medium grade, Funnel, wiremesh, etc. complete all as specified and directed by Engr-in-Charge including testing on completion.
10
-
-
Labour for restretching/tightening the existing LT overhead conductors & GI earth wire mounted on insulators of any type on poles manually or by mechanical means to the extent of permissible sag and tension and binding with steel wires of appropriate size complete having 5 to 7 conductors per span of approx 35-40 mtr length between poles and tightning of stay wire etc complete all as specified and directed.
50
-
-
Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium 6 Sqmm stranded conductor, Twin core cable flat served with inner sheathing of PVC tape and overall PVC sheathed in service connections including taking down existing one complete all as specified and directed.
250
-
-
S & F in replacement of LT Jumper with the help of Aluminium Counductor Steel Reinforcement. The length of jumper shall not be less than 2 meter including connection with the help of connector and aluminium lugs, nut bolt washers etc on the LT Pole complete all as specified and directed.
34
-
-
Pruning / trimming of branches of trees interfering or overhanging on electrical overhead lines in such a way to have a clearance of not be less than 2 mtrs all around the outermost conductor of the span complete all as specified and directed. Note: Span shall be measured pole to pole as One Span.
45
-
-
M&L in replacement aluminium conductor steel reinforced fixing on the over head LT pole with the help of aluminium tapes/ binding wire including taking down existing one complete all as specified and directed.
1.5
-
-
S & F in replacement pin type porcelain vitreous white brown or green insulator of size 100 mm height, 65 mm dia suitable for 1100 volts grade including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut including taking down existing one complete all as specified and directed..
50
-
-
S & F in replacement Shackle type porcelain vitreous white brown or green insulator of size 100 mm height, 115 mm dia suitable for 1100 volts grade including two galvanised mild steel straps, washers, insulators bolts and nut etc including taking down existing one complete all as specified and directed..
30
-
-
M&L in replacement stay assembly complete with accessories as shown in electrical plate no 1 including loop type insulator, stay clamps, stay strands, excavation work of any type of soil strata and PCC work and taking down existing one complete all as specified and directed
4
-
-
Labour for tightening/re-stretching of stay assembly complete with accessories such as Stay stranded wire, Stay Clamps, Bow including replace the damaged oval/loop type insulator with new one etc complete all as specified and directed
2
-
-
M&L for plain concrete cement (1:3:6) type C2 (Using 40mm graded coarse aggregate) for foundation, filling and mass concrete of poles including necessary form work complete all as specified and directed.
8
-
-
Supply & Fix including commissioning digital automatic timer switch distribution panel board, factory assembled in powder coated steel sheet enclosure, comprising of 4P MCB, 40 Amps & 40 Amps 3 Pole power contactor and 230V digital time switch for controlling LED street lights, including earth work for fixing Timer switch distribution panel board and shall be provided 4 Nos 20x20x3mm thick angle iron supports of not less than each 0.6 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth complete all as specified and directed
2
-
-
M&L for PCC (1:3:6) type C1 (Using 20mm graded coarse aggregate) for coping of poles including fair finishing the exposed surfaces even and smooth without using extra cement including necessary formwork complete all as specified and directed.
1
-
-
Supply & Fix on pole, SMC Junction box inner dimensions (270 x 225 x 135)mm (LxBxD), 3 phase 4 wire system, including cable connecting base, 6 Amp DP MCB with mounting SS railing, Cable lugs suitable to 10/16 Sqmm 4 core cable, connection for incoming and outgoing cables including Fixing arrangement on pole etc complete all as specified and directed
20
-
-
M&L in replacement steel tubular swaged poles complete with cast iron base plate finial taper plug bolts nuts & screws as specified type 410 SP-31 (9 mtrs long) as Pole/Strut including dismantling old/US steel struts, complete all as specified and directed.
4
-
-
M&L for preparation of existing surface of steel tubular pole by srapping down peeled off old paint, cleaning etc of length 8.5/9/11 mtrs and cross arms etc and applying one coat of aluminium coat paint including rewriting pole Nos as directed with black paint complete all as specified and directed
300
-
-
M&L for LT UG Cable fault finding/testing from FP Box to fault location including taking shut down and opening the cable from both side of Bus Bar Panel/LT Panel/MCCB/ACB/Transformer etc and re-terminated the same cable in the same Bus Bar Panel/LT Panel/MCCB/ACB etc according to existing system after completion of fault finding/testing work complete all as specified and directed of following sizes cables :-
Note:- Job will be measured after fault detection of any type regarding this decision of Engineer-in-charge shall be final & binding.
3.5 Core 300 Sqmm
2
-
-
Ditto all as per item No 65 above but 3.5 Core 240 Sqmm
2
-
-
Ditto all as per item No 65 above but 3.5 Core 185 Sqmm
1
-
-
Ditto all as per item No 65 above but 3.5 Core 150 Sqmm
3
-
-
Ditto all as per item No 65 above but 3.5 Core 120 Sqmm
2
-
-
Ditto all as per item No 65 above but 3.5 Core 95 Sqmm
4
-
-
Ditto all as per item No 65 above but 3.5 Core 70 Sqmm
2
-
-
Ditto all as per item No 65 above but 3.5 Core 50 Sqmm
3
-
-
Ditto all as per item No 65 above but 3.5 Core 35 Sqmm
3
-
-
Ditto all as per item No 65 above but 3.5 Core 25 Sqmm
2
-
-
M&L for core cutting in any type of wall size from 40mm to 80mm dia including make good to existing one complete all as specified and directed .
1
-
-
Labour for disconnecting the LT UG Cable (approx 10-12 No of Cables) of any size from LT ACB breaker and setting aside at safe place/side by taking proper shut down for human saftey, cleaning the duct/trench by removing foreign material/mud from trench/duct including reconnecting the all LT UG Cables according to existing system complete all as specified and directed
20
-
-
M & L in replacement for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones of Post Office RED Colour and fixed on LT Poles with M.S. clamps, bolts and nuts of required size, for 440 Volts LT of size 200 X 150mm complete including taking down existing one complete all as directed.
25
-
-
M & L for route tracing of LT UG cables under ground/road from one end to another end of cable, size upto 400 sqmm including taking shut down and opening the cable from both side of Bus Bar Panel/LT Panel/MCCB/ACB/ Transformer etc and re-terminated the same cable in the same Bus Bar Panel/LT Panel/MCCB/ACB etc according to existing system after completion of route tracing work complete all as specified and directed.
8
-
-
M & L in replacement of GI Earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level in any type of soil strata, connected to galvanized iron strip 25 x 4 mm by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 3 of MES schedule 1991 Part – I connected to machinery/equipment for LT Panel, Feeder Pillars, Sub Feeder Pillars etc. as required including necessary excavation and earth work, concrete pit, chamber and pit cover in PCC 1:2:4 type B1 including lifting handle and Earth lead and 20mm Dia GI watering pipe medium grade, Funnel, wiremesh etc. complete all as specified and directed by Engr-in-Charge including testing on completion.
15
-
-
S & Fix in replacement PVC spiral spacer for LT overhead line of gray colour suitable for 3 phase 4 wire system, length of the spacer should not be less than 1200mm including taking down existing one and all arrangements shall be adopted by contractor for the same complete all as specified and directed. Note : Necessary ladder & scafolding etc if required for this job is the responsibility of the contractor and rates included in this Job.
30
-
-
S & Fix in replacement Sheet Metal Enclosures factory made Tripple Pole and Earth enclosure with a three pin and earth plug with 63 Amp Industrial socket complete with one Four Pole MCB of 63 Amp, 415 Volts, 10 KA including wall mouting accessories and connection to Boiler complete all as specified and directed
5
-
-
S & F in replacement of GI strip 25 x 4 mm earth as earth continuity conductor or main earthing lead fixed to wall batten or recess or chases or buried in ground or fixed to poles or any other indicated situation etc. complete all as specified and directed
60
-
-
S & Fix in replacement of Cable Route Marker made up of Cast Iron of dia 80 mm and thickness 4.65 mm with supporting angle iron of size 20 x 20 x 3 mm and height 0.6 mtr for stand including priming, painting and wirting of "LT UG CABLE" in suitable size of letter including necessary earthwork and grouted at suitable depth in PCC 1:3:6 Type C2 using 40 mm graded aggregate in mass concrete complete all as specified and directed at site by Engr-in-Charge.
150
-
-
S & F in replacement Busbar panel weather proof outdoor type single door, fabricated out of 2 mm thick CRCA sheet with epoxy powder coating of RAL-7035 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-54, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars electrolytic grade of 400 Amps current rating including required size of nut bolts for fixing of cables upto 240 Sqmm. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding and fix horizontally. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment. All joints and connection shall be done with galvanised or cadmium plated high tensile nuts, bolts, washers and AL Lugs etc. The panel shall be provided with 04 Nos 50mmx50mmx5mm thick angle iron supports of not less than each 0.9 mtr height duly painted with anti corrosive black paint including earth work and grouted in PCC 1:3:6 at suitable depth as per site requirement including taking down existing one. The overall size of the Busbar panel shall not be less than 500mmx300mmx700mm (LxWxH) including 4 Nos cable entry holes suitable for cable entry up 3.5C 240 Sqmm at bottom complete all as specified and directed Engr in Chrage.
15
-
-
M&L preperation of old/new steel surfaces over 10 cm in width or girth not otherwise described and applying 2 coats of synthetic enamel paint over a coat of red oxide primer.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements