Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Survey Works
Eprocure
Opening Date21 Sep 2020
Closing Date19 Oct 2020
Tender Amount₹ 25,78,558 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 60,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_MES_379381_1Bid Award Id
ViewTender No
86791/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
TENDER INVITING FOR REPAIR MAINT OF POWER DISTRIBUTION TRANSFORMERS, RMU, VCBs, CONTROL PANEL TESTING AND CALIBRATION OF EARTH FAULT RELAYS, HT.LT CABLE, OH LINES,GODs AND OTHER CONNECTED WORKS AT DEOLALI UNDER GE DEOLALI
BOQ Items
... More
Labour only for taking out unserviceable winding wire and material and labour for Reconditioning of LT copper strip existing size including Insulating material with latheorised paper insulation, cotton tapes empire tapes, wooden block packing and PVC sleeve soldering and varnishing with insulating varnish, heating drying ,testing of colis etc complete Transformer capacity of 250/500 KVA
Note : Reconditining and testing of transformer to be carried out through approved firm.
10
-
-
... More
All as per item No 4 above but transformer of 125/200 KVA capacity
6
-
-
... More
All as per item No 4 above but transformer of 50/100 KVA capacity
4
-
-
... More
Checking of old transformer oil and re-filling the same to transformer after centrifuging of oil with filtration machine. The machine continuously will run round the clock till obtaining the result of oil upto 50 KV die electric strength in 2.5 mm gap complete all as directed by Engineer-in-Charge.
Note : cenrifuging of transformer oil is to be carried out at various E/M installation& workshop Transportation of T&P& M/C is to be included in item rate
18000
-
-
... More
M&L for Filling /topping of new transformer at various location at site as directed ,transformer oil Confirming to IS: 335 having dielectric strength not less than 60 KV complete including centrifuging of oil (if required) up to getting dielectric strength near 60 KV all as specified and directed by the Engineer-in-Charge Make:- Power oil & Equivalent approved by GE Note :(i) Transformer oil shall be supply only in sealed barrel of 210 ltr each (ii) Item Rate includes transportation & T&P reqiuired
1400
-
-
... More
M & L for HT bushing out door/In door type 11 KV, HV made up of free machining brass rod complete with neoprene seal rings, locking nuts as per IS 3347/1967 complete with porcelain bushing and gasket etc complete with current rating up to 250 Amps.
6
-
-
... More
M & L for LT bush rod out door/In door type 1.1 KV L.V made up of free machining brass rod complete with neoprene seal ring, locking nuts and other accessories of working current rating 250 Amps 12mm as per IS 3347/1967
16
-
-
... More
M & L for LT bush rod out door/In door type 1.1 KV L.V made up of free machining brass rod complete with neoprene seal ring, locking nuts and other accessories of working current rating 400 Amps 20mm as per IS 3347/1967
14
-
-
... More
M & L for LT bush rod out door/In door type 1.1 KV L.V made up of free machining brass rod complete with neoprene seal ring, locking nuts and other accessories of working current rating 630 Amps 25mm as per IS 3347/1967
8
-
-
... More
M & L for Breather container of suitable for 11 KV up to 500 KVA distribution transformer Capacity
8
-
-
... More
M&L for replacement of old silica gel breather with new one of suitable capacity (500g-1000g) complete all as specified for trasformer 100 KVA to 500 KVA all as directed.
10
-
-
... More
M&L for repairs to leaking transformers at site up to 500 KVA by opening the top cover, draning the transformer oil to the level just below the bushing, replacing the all four bushing with connecting rod, replacing the oil gaskets of bushings on HT & LT side, replacing the top oil gasket, reassebling, testing etc comlpete all as directed.
6
-
-
... More
Material and labour for painting of 11 KV distribution transformer of capacity 50 KVA to 250 KVA with synthetic enemel paint two coats by spray painting approved colour after scraping of old paint, cleaning of all rusted portion, surface including sign writing i.e MES No, Make, Capacity etc complete all as directed by Engineer-in-Charge
20
-
-
... More
Ditto all as per above item No 17 but transformer capacity above 315 KVA and up to 630 KVA.
10
-
-
... More
Repair/Maintenance of electric control wiring of tripping circuit, indicating lamp and selector switch circuit and metering equipment including replacement of burnt wires by proper clipping with lugs, cable ferrules and connectors etc making the circuit proper functional of HT VCBs, OCB’s and ACB’s all as specified and directed by the Engineer-in-Charge.
2
-
-
... More
Supply, installation, testing and commissioning of CT 11 KV epoxy type ratio 150-75/5 Amps, accuracy Class-I single pole (Three core type) fixing on existing 11 KV panel including necessary connections, any modification required, addition/alteration required for fixing CT in existing 11 KV panel complete all as directed by Engineer-in-Charge.
3
-
-
... More
Supply, installation, testing and commissioning of CT 11 KV epoxy type ratio 100/50/5+5 Amps accuracy Class-I single pole (Three core type) fixing on existing 11 KV panel including necessary connections, any modification required, addition/alteration required for fixing CT in existing 11 KV panel complete all as directed by Engineer-in-Charge.
3
-
-
... More
Supply in replacement of indicator lamps of OCB/ VCB Panel 24/36 /110 volt of existing size
6
-
-
... More
Calibration of digital/IDMT protective relays of HT panel (VCB's) as per load pattern, by preparing data sheet of existing electric load from each sub stations, re-programming input data into relays (OCHS, EFHS, OCLS, EFLS, CTR, TDS etc) complete testing by injecting current in CT primary and measure secondary current at 11 KV, control and relay panel for metering, protection relay plug settings intended in service through current injection in CT primary and ratio including complete polarity test complete all as specified and directed.
9
-
-
... More
Calibration of digital/IDMT protective relays of HT panel (VCB's) as per load pattern, by preparing data sheet of existing electric load from each sub stations, re-programming input data into relays (OCHS, EFHS, OCLS, EFLS, CTR, TDS etc) complete testing by injecting current in CT primary and measure secondary current at 33 KV, control and relay panel for metering, protection relay plug settings intended in service through current injection in CT primary and ratio including complete polarity test complete all as specified and directed.
Note for Calibration of VCBs : 1. Gen back up required during testing shall be arranged by contractor for which rate are deemed to be included in item rate 2. All testing shall be carried out in presence of engr in charge and test certificate shall be submitted in duplicate duly signed by contractor
3
-
-
... More
M & L for preventive maintenace/periodical servicing of 11KV VCBs of make CG by dismantling of breaker mechanism, checking the various critical setting in mechanism, checking of spring charging mechanism, checking of pole contact setting, greasing/ lubricating of mechanism moving parts, checking of contact pressure, alignment and adjusting the same, adjusting of spring charging mechanism & triping test trial & testing of VCBs for smooth and correct fuctioning complete all as directed. ( Umrao Vihar)
4
-
-
... More
Replacement of defective relays with digital protective relays 3 phase over current and earth fault (04 NO - Programmable i.e. 2NO + 2NC programmable) with high set, CT rating 5A, Aux. supply 24 -110V, TMS range 0.01 - 1.6, 35mm LCD Display, including initial setting of parameters as per existing load of feeder/transformer, in replacement against ser item 1 here in before in existing panel including addition/alteration as required at site, testing complete all as directed by Engineer-in-Charge. Make : L&T Cat Part No. MC-61AnX or equivelent as approved by GE
3
-
-
... More
Replacement of defective Master trip relay as per existing make for 11 KV VCBs including necessary electric wirings all as specified and directed
6
-
-
... More
S&F in repairs ammeter with 3 Phase ( R-Y-B) selection of rating 0-100 Amps digital type of existing 11 KV VCBs of make- ABB and making all necessary electrical connections complete all as specified and directed (Umrao Vihar). Make: Rish Eine or equvalent make of MECO of same spacification
1
-
-
... More
M&L for triping/ closing coils suitalbe for 33KV of make ABB out door type complete all as specified and directed.
1
-
-
... More
M&L for closing coils suitalbe for 11 KV VCB of make ABB indoor door type complete all as specified and directed.
1
-
-
... More
M&L for triping coil suitalbe for 11 KV VCB of make ABB indoor door type complete all as specified and directed.
1
-
-
... More
M&L for over current and earth fault relay of make L&T, Model No - MC-31A,sutable for 11 KV VCB ( indoor type) all as specified (Umrao Vihar incomer)
1
-
-
... More
Supply and fix and testing in replacement OC & EF IDMT Relay Model Name/Number: ADR-141 C, 18-230 V DC, make- Ashida suitable for 11 KV VCB.( MAP Feeder umrao vihar)
1
-
-
... More
M&L for Rarchet gear sutable for spring charging mechanism of 11 KV VCB of make: ABB all as specified.( Umrao vihar)
1
-
-
... More
Supply and fix lead-acid battery 180 AH 12 Volts model XP-1800 of make Exide or eqivalent of other approved make
3
-
-
... More
Supply and fix lead-acid battery 50 AH 6 Volts model of make Exide or eqivalent eqivalent of other approved make
1
-
-
... More
Supply , fix & test Spring Charging Motor of ABB 33 KV VCB at umrao vihar sub station.
1
-
-
... More
Supply, testing and commissioning of maintenance free battery bank rating of overall 30Volts DC (15 Nos each of 2 Volts) 150AH, any other parts including necessary electric leads up to battery charger, relays etc., as required at site, complete testing all as directed by Engineer-in-Charge.
2
-
-
... More
Supply, laying & testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor 11000 volts grade (E), of size 3 Core 120 sqmm complete all as specified.
110
-
-
... More
M & L for cable jointing kit Out door type for 33 KV grade cable for End termination heat shrink type complete with jointing material and accossories suitable for 3 core XLPE armoured aluminium conductor cableof size 300 Sqmm outdoor type, complete all as specified.
1
-
-
... More
Supply and jointing heat shrinkabble end termination joints for 11 KV XLPE cable size 50 Sq mm to 95 Sq mm 3 core Outdoor type complete all as specified and as directed. Make : Mseal/Raychem/3M
3
-
-
... More
Supply and jointing heat shrinkabble end termination joints for 11 KV XLPE cable size 120 Sq mm to 185 Sq mm 3 core Outdoor type complete all as specified and as directed. Make : Mseal/Raychem/3M
5
-
-
... More
Supply cable jointing kit with heat shrinkable straight through joint box including jointing materials suitable for 50 Sq mm to 95 Sq mm 3 core XLPE 11 KV cable complete all as specified. Make : Mseal/Raychem/3M
4
-
-
... More
Supply cable jointing kit with heat shrinkable straight through joint box including jointing materials suitable for 120 Sq mm to 185 Sq mm 3 core XLPE 11 KV cable complete all as specified and as directed. Make : Mseal/Raychem/3M
4
-
-
... More
Tubes "light grade" galvanised iron, laid under roads/drain, fixed to poles, walls, with flat iron clamps bolts/nuts/washers of the following sizes of 150 mm diabore complete all as specified and directed.
6
-
-
... More
Tubes "light grade" galvanised iron, laid under roads/drain, fixed to poles, walls, with flat iron clamps bolts/nuts/washers of the following sizes of 100 mm diabore complete all as specified and directed.
6
-
-
... More
Tubes "light grade" galvanised iron, laid under roads/drain, fixed to poles, walls, with flat iron clamps bolts/nuts/washers of the following sizes of 80 mm diabore complete all as specified and directed.
12
-
-
... More
Supply and fixing cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including a coat of red oxide primer one underand & one finishing coat complete all as specified and directed.
2
-
-
... More
M&L for Cement concreat in foundation, filling and mass concreta type B2 using 40mm graded aggregate 1:2:4 complete all as specified
4
-
-
... More
Excavating in trenches n. exc 1.5 m wide ,depth exc. 1.5m but n.exc. 3.00m for foundation, etc. or for laying/taking out cables etc.n exc 10 sq m on plan and getting out , all as specified.
29.7
-
-
... More
Returning, filling in, including spreading , leveling , watering and well ramming in layer not exceeding 25cm each layer all as specified.
21.7
-
-
... More
Removing excavated material not exceeding 50M and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified.
8
-
-
... More
Sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches complete all as specified. Note - for measurement purpose punned thickeness 18 CM shall be considered
7.1
-
-
... More
M & L for laying unreinforced precast concrete cable cover, Class LV, type-1, flat, size 250x150x40mm complete all as specified and directed.
587
-
-
... More
Supplying, install and errect in true vertical position steel tubular swaged welded pole complete with cast iron/MS base plate 6mm thick and of size 300x300mm, final taper, pole cap, bolts, nuts, washers & screws etc. pole made out of ERW M.S. tubing conforming to IS-2713 part-II type 410 SP-55 (11.0 metre long) HT including of holes of reqd Nos and size for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, all as specified and directed by Engr-in-charge.
6
-
-
... More
S&F disc insulated porcelain vitreous 145 mm heigh 255 mm dia ball and socket type white / brown or green single disc assembles for tension with tension GI clamps for conductors working pressure 11 KV complete all as specified and directed.
10
-
-
... More
Supply and fixing pin type insulator porcelain vitreous with brown of green including one galvanised mild steel spindle two galvanized iron washer and galvanized iron nut, 150 mm height and 150 mm dia 11000 volt grade all as specified and directed
12
-
-
... More
Repair/overhauling of air break switch 33 KV complete by applying electrolytic grease to stationary, and moving contacts, and replacing unserviceable fexible copper earth strips, GI nuts, bolts, operating mechanism and operating handle( 32mm med GI pipe Approx 5.0 RM) etc incl alingment for smooth functioning from ground level all as req uired at site and as directed by E-in -charge.
3
-
-
... More
M&L for 33 KV rated horizontal mounting 400 / 600 Amp Gang operated Air break off load, disconnecting switch. Tripple pole, each pole consists of Galvanized steel base, HT Insulators as per BSS./I.S non-ferrous knife and spring loaded contacts, arcing horns of adequate section to break magnetizing current of the transformers horizontal GI pipe of adequate lenghth for phase separation, adequate length of GI pipefor operation from ground level and operating handle complete in both OFF and ON position complete all as specified.
2
-
-
... More
Suppy and fix post insulator for 33 KV line.
6
-
-
... More
Suppy and fix pin insulator for 33 KV line.
6
-
-
... More
Supply and fix Disc insulator with hardware fitting for 33 kv line.
8
-
-
... More
M&L for scrubbing out old paint, rust etc from HT 33 KV main receiving yard (AC Power House) consisting of vertical channel 14 Nos and horizontal channel 40 Nos, Capacitor bank structure- 2 nos consisting GI Pipe, Brasing frame, clamps and all nut and bolts including fencing 50 mlong and 2 mtr height and making smooth and even surface then painting with one coat of anti rust paint and two coat of superior quality aluminium paint on entire exposed portion of 33 KV yard structure all as directed at site
1
-
-
... More
M&L for scrubbing out old paint, rust etc from HT 33 KV main receiving yard (MAP Power House) consisting of vertical channel 16 Nos and horizontal channel 20 Nos, Capacitor bank structure-01 no consisting GI Pipe, Brasing frame, clamps and all nut and bolts including fencing 30 mlong and 2 mtr height and making smooth and even surface then painting with one coat of anti rust paint and two coat of superior quality aluminium paint on entire exposed portion of 33 KV yard structure all as directed at site
1
-
-
... More
M&L for 11 KV under ground cable f any size fault locating with the help of vehicle mounted fault locating device using of giving external power supply 11 kv and detecting through voice capturing mic including tracing out exact fult/ damaged portion of cable with necessary excavation work And testing the same after the repiar all as specified and directed.
3
-
-
... More
M&L for Earthing complete with GI earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.65 Mtr below normal ground level connected to GI strip 32 x 6 mm size and earthing lead protected with 50 mm bore GI pipe, light grade, filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate including chamber PCC 1 : 3 : 6 type C1. using 20 mm graded crushed stone aggregate in concrete pit pre-cast RCC 40 mm thick reinforced with 6 mm dia round at 75 mm C/C both way with 12 mm dia mild steel plain bar lifting handle 2 Nos funnel with wire mesh 20 mm dia GI pipe light grade watering pipe and frame work complete all as shown in electrical plate No. 3 of SSR Part-I 2009 including testing on completion.
10
-
-
... More
Supply and installation of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawin in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 32x6mm GI strip incl taking down u/s strip any type complete
50
-
-
... More
Supply & fix aluminium strip 25mmx 3mm as a roof conductor or down conductor complete all with saddles and fixing screws for fitting the strip incl taking down any type strip complete all as specified and directed by Engr-in-charge at site.
50
-
-
... More
S&F LED flood light Energy saving, environment friendly, long life, exclusive innovative die-cast aluminium flood light 200 W
Make Havells JETAirisplusfls200wled757psymltg
10
-
-
... More
Supply, fabricate, erect, connect, test and commissioning of factory made, CPRI approved, cubical type, Indoor type LT panel board, totally enclosed, dust, weather and vermin proof 1100 Volt grade, 50 HZ supply made out by 3.15mm thick CRCA sheet for load bearing and 2mm thick for non load bearing, fully compartmentalised, painted with powder coated paint, angle iron padastal frame 600mm hight above ground level all as per conforming to IS-2417 of 1962, complete including the following accessories for each set all as specified and directed. (Loc- AGE E/M Yard)
(a) 4 Nos bus bar of equal size made out of Aluminium strip of suitable size with PVC insulated coloured heat shrinkable type sleeves, of rating 600 Amps, for looping and branch connection system, mounted on non cracking resin type insulators - 01 Job.
(b) TPN, 4 Pole, MCCB ( thermal magnetic release) 400 Amps, 415 Volt, 36KA - 01No. (incoming)
(c) TPN, 4 Pole, MCCB ( thermal magnetic release) 250 Amps, 415 Volt, 25KA - 03No. (Outgoing)
(d) TPN, 4 Pole, MCCB ( thermal magnetic release) 100 Amps, 415 Volt, 25KA - 02No. (Outgoing)
(e) TPN, MCB 63 Amps, - 02No. (Outgoing)
(f) SPN, MCB 32 Amps, - 02No. (Outgoing)
(g) Indication lamps R, Y & B - 01 Set
(h) Provisioning of copper tinned cable glands for incoming and outgoing cables - 01 Job.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements