Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date21 Nov 2024
Closing Date10 Dec 2024
Tender Amount₹ 43,50,000
Costs
EMD
₹ 87,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_684898_1Tender No
8394/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in roof covering fixed with self tappping screws complete all as specified.
60
-
-
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 10cm long and dia of neck is 11 to 15mm, complete all as specified.
10
-
-
S&F Plates (plain or cheqered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, complete all as specified.
40
-
-
M&L for Preparation of New surface of steel and apply two coat of synthetic enamel paint over a coat of pink primer ,complete all as specified.
15
-
-
Taking down cement plaster on brick/stone or concrete surface including racking out joints, hacking for key, scrubbing down with water to receive plaster, including removing debris/rubbish materials off the site, complete all as specified.
650
-
-
M&L for cement plaster in CM 1:4, 20mm thick in two layers (1st layers of15 mm thick base coat in CM 1: 6 and 2nd layer of 5 mm thick finishing coat in CM 1:4 ) with using integral waterproofing compound finished even & smooth without using extra cement ( Note: Integral liquid water proofing compound to be used in per bag of cement shall be as per manufacturers instructions and paid separately under respective items.).
250
-
-
M&L for rendering 15mm thick in cm 1:6 on brick work or concrete surfaces and rendering is to be finished even and smooth (without using extra cement), complete all as specified and directed.
250
-
-
M&Lfor rendering 10 mm thick in cm 1:3 on fair faces of concrete as in soffit/ ceilling or slab, chhajjas finished even and smooth without using extra cement complete all as specified and directed.
150
-
-
Supply only liquid water proofing compound.
20
-
-
M&L for preparing newly plastered surfaces of walls and applying 2 coats of Oil Bound Distemper over 2mm thick wall care putty on walls complete all as specified and directed.
250
-
-
M & L for Preparation of new surfaces of ceiling and applying two coats of Oil bound distemper over a coat of primer complete all as specified.
150
-
-
M&L for Prepartion of new wall surfaces and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), all as specified.
250
-
-
M&L for complete removal of existing treatment on old surface of walls and applying 2 coats of Oil Bound Distemper over 1 mm thick wall care putty on walls complete all as specified.
250
-
-
M & L for Preparation of old surfaces of ceiling and applying two coats of Oil bound distemper, complete all as specified.
150
-
-
M&L for Preparation of old wall surfaces and Fiinishing walls with Acrylic Smooth exterior paint of required shade : New work (Two coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) , complete all as specified.
150
-
-
Dismantling floor hearth or wall tilling including cement mortar bedding ( but not backinig ) all as specified by Engr in-charge.
400
-
-
M&L for non skid ceramic tiles (coloured) 7 to 8 mm thick ( square/rectangular) area of each tile exc 0.06sqm but n.exc 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including screed bed 15mm thick in CM 1:6 complete all as specified and directed.
25
-
-
M&L Coloured Glazed Ceramic tiles 300 x 450mm and 6-7mm thick on vertical surfaces such as skirting, dados and risers to steps, shelves etc including 10mm thick backing coat in CM 1:4 complete all as specified and directed.
225
-
-
M&L for Verified ceramic coloured tiles 10 mm thick ( square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6, design and colour as approved, complete all as specified.
150
-
-
M&L for Granite slab work 18 to 20mm thick in floors steps platforms, shelves etc and fixed over cuddappa stone by usiingg aerolite adhesive complete all as specified and directed.
145
-
-
M&L for machine cut cuddappa stone slab 20 to 25mm thick pre-polished as in cills/jambs/ soffits of window & in door openings in one length, in shelves etc. set jointed and pointed in cement mortar 1:4 and slurry with grey cement slurry mixed with pigment to match the shade of the slab, complete all as specified.
50
-
-
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing etc. and making good, cutting not exc 10 cm girth, complete all as specified.
325
-
-
Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) , complete all as specified.
1
-
-
Demoltion of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified.
2
-
-
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6mm mean radius built in cement mortar 1:6 , complete all as specified.
2
-
-
M&L Brickwork with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 , complete all as specified.
45
-
-
S&F in repair Soap dish, any type fixed to plugs with chromium plated brass screws all as specified and directed by Engr-in-Charge.
2
-
-
S&F as in repairs Aluminium anodised Tubular towel rail, 20mm dia, D type, 60cm long between flanges, complete all as specified.
2
-
-
M&L cast iron floor trap 75mm dia with grating including jointing to wste pipe fixed in cement concrete type B1 (1:2:4) etc, complete all as specified.
2
-
-
S&F 600 X 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers , complete all as specified.
2
-
-
Taking up or down 20mm dia bore steel tubing and connections, including cleaning for re-fixing and removing to store , complete all as specified.
20
-
-
Taking up or down 15mm dia bore steel tubing and connections, including cleaning for re-fixing and removing to store , complete all as specified.
15
-
-
S&F GI tubing medium grade including all fittings fixed in floor/walls/ceilling of 15mm bore , complete all as specified.
15
-
-
S&F GI tubing medium grade including all fittings fixed in floor/walls/ceilling of 20mm bore , complete all as specified.
20
-
-
S&F Vitreous chine wash basin, oval type of size 630mmX450mm including CI bracket 1 pair CP waste coupling 32mm, CP brass pillar cock 15mm bore swan neck, PVC connector 450mm by with CP brass unions suitable for 15 mm bore PVC waste pipe including 32mm bore of suitable length etc fixed, complete all as specified.
2
-
-
S&F as in repairs vitreous China squatting pan, 'Orissa' pattern, size 580 X 440mm white, with integral foot rests, complete all as specified.
2
-
-
S&F as in repairs Vitreous China wash down water closet pan (pedestal pattern), including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, complete all as specified.
1
-
-
S&F as in repairs health faucet (ABS Body mild steel chromium plated suitable for 15mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including making connections and fixed in position , complete all as specified.
2
-
-
S&F as in repairs 10 litres PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, complete all as specified.
3
-
-
S&F as in repairs Vitreous China Urinal, Half stall type, white, complete including providing and fixiing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, complete all as specified.
2
-
-
S&F in repair 15mm bore Chromium plated stop valves, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified.
5
-
-
S&F in repair bib taps fancy cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule 15mm bore , complete all as specified.
4
-
-
S&F PVC connections with brass socket on both side 60cm for 15mm dia pipe , complete all as specified.
5
-
-
Dismantling of water tank of capacity exc 500 litres but n.exc 1000 litres ,complete all as specified.
2
-
-
S&F 500 litres of capacity Rotational moulded polyethlene water storage tanks triple layered (cylindrical vertical with closed top) hoisted and fixed in position including 20mm bore dia Ball brass valves, high pressure, with polythene float and flynit complete, screwed for iron pipe or brass ferrule and fixed , complete all as specified.
2
-
-
Taking down aluminium sliding windows of any description and any size and repalcing the wornout, broken wiremesh, aluminium sections, glass, grill,, rubber beading, rollers, locks, etc as required and refixing back into the same opening for easy movement of shutters including necessary fittings and fixtures ( Note : items such as wirmesh, Glass, grill, rubber beading, rollers, locks, aluminium section etc will be paid seperately under respective items as supply only.
10
-
-
Supply only Stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples , complete all as specified.
10
-
-
Supply only PVC Star lock for Aluminium windows.
15
-
-
Supply only Nylon / PVC Rollers for Aluminium Windows.
20
-
-
Supply only Rubber beeding suitable for aluminium door/window shutters.
20
-
-
Taking down chowkhats or frames exc 1.5 Sqm & n. exc 4 sqm with shutters (without taking off shutters from the frame), complete all as specified & directed
4
-
-
Taking down chowkhats or frames exc 1.5 Sqm with shutters (without taking off shutters from the frame), complete all as specified & directed
2
-
-
Taking down shutters of any description exc 1 Sqm and n.exc 2 Sqm each, complete all as specified.
1
-
-
S&F factory made single exstruded WPC (Wood polymer composite) solid door/ window ceosetory window & other frames/ chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K Value 58-60 (suspension Grade) calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk ) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100N (Edge), minimum compressive strength of 58N/ mm2 , modules of elasticyty 900N / mm2 and resistance to spread of flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/ SS dash fasteners of required dia and length complete as per direction of Engineer -in - charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note :- For WPC Solid door/ window frames, minus 5 mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile but no extra payment on this account shall be made.
15
-
-
S&F factory made single extruded WPC (Wood polymer composite ) solid plain flush door shutter of 30 mm size comprising of virgin polymer of K value 58-60 ((suspension Grade) calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk ) and non toxic additives (maximum toxicity index of 12 for 100 gms) f having minimum frame density of 650 kg/ cum, screw withdrawal strength of1800 N (Face) & 900N (Edge), minimum compressive strength of 50N/ mm2 , modules of elasticyty 850N / mm2 and resistance to spread of flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per direction of Engineer -in - charge. Note Stainless steel butt hinges and necessary S S Screws shall be paid separately)
20
-
-
M&L for cutting holes in bricks walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar or cement concrete 1:2:4 type B1 as required exc half brick but not exc one brick complete and as directed
8
-
-
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Squar tube, suppling & fixing in opening as per specification, complete all as specified.
9
-
-
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification complete all as specified.
3.5
-
-
S&F 150mm long Aluminium handles, cast type, anodised all as specified and directed by Engr-in-charge.
8
-
-
S&F 100mm size stainless steel Butt hinges 1.75mm thickness, with matt finish, complete all as specified.
12
-
-
S&F 150mm long Aluminium anodised, barrel tower bolts of ex-truded section and fixed all as specified and directed by Engr-in-charge.
8
-
-
S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy , complete all as specified.
2
-
-
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for chowkats shuttersof doors, windows & ventilators, sliding windows including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc including suitable nylon rollers, star lock with handle with complete fittings. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions
300
-
-
S&F powder coated Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handless and fixing approved anodised aluminium standard section around the opening, all complete as per specified.
15
-
-
S&F 4mm thick glass, ordinary quality and glazing with suitable sections, complete all as specified.
25
-
-
S&F 6mm thick prelaminated plain colour backlite sheet & fixed in aluminium partition, complete all as specified.
3
-
-
Removing existing water proofing treatment what so ever exist (except concert padding) and removing debris/ rubbish materials off the site complete all as specified and directed.
50
-
-
M&L for APP modified roof treatment over existing RCC roof with folling specification :-
(a) Applying bitumen primer @ 0.4 Liters/Sqm with density of 0.87 to 0.89 Kg/Liters at 25 degree C on the prepared dry roof surface.
(b) Laying 3 mm thick APP membrane weight not less than 3.50 Kg/Sqm by torch application with minimum 10cm side lap and 15cm end lap. The laying of membrane shall be done through an authorised applicator of manufacturer of APP membrane.
50
-
-
Removal of existing concrete including loose/weak concrete from the concrete structure i.e. beams/ columns/ deckslab etc upto beyond corroded steel reinforcements to a depth of minimum 10mm minimum behind the reinforcement by chipping/hacking with chisel and hammer or by mechanical means like chisel hammer, pneumatic chippers including high pressure water jetting and removal of debris. Concrete around the corroded reinforcement shall be removed properly. The edges of the repair locations of concrete should be saw cut to depth of at least 10mm to avoid featheredging and to provide a square edge complete all as specified and directed by Engr-in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
225
-
-
M&L for Preparation of surface and removal of rust in the loosely bonded concrete of the RCC deckslab, beam / girder and piles shall be chipped out using the mechanical cutter exposing the bars and applying Rust Remover using small brush and allow to react it for 16-24 hrs. Before applying protective coating,the surface should be wire brushed and thoroughly cleaned for dust with dry cloth complete all as per manufacturer instructions and directed by Engr- in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
225
-
-
M&L for applying two coats of Anti-Corrosive Primer two component (epoxy anticorrosive zinc rich coating) on reinforcement steel surfaces uniformely. Coating shall be applied by the brush to the exposed and cleaned rebars with an interval of 45 minutes to 1 hour @ 40microns DFT / coat and allowed to completely dry for 24 hours complete all as per manufacturer instructions and directed by Engr- in-Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
225
-
-
M&L preparation of concrete surfaces by removing loose concrete, dust, dirt etc, cleaning the surface properly and applying one liberal coat of epoxy bonding agent ( two component agent) by brush application complete all as per manufacturer instruction and directed by Engr-in- Charge Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
225
-
-
M&L 50mm thick polymer modified mortar ( average thickness) modified single component, alkaline resistant fibre reinforced, thixotropic, cementitious patch repair mortar on conrete structure. Applying the mortar arround the reinforcement and finishing to bring it in line with existing concrete surface complete all as per manufacturer instructions and directed by the Engr-in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
225
-
-
M&L for holes of dia 16mm and depth 100 mm drilled @ a spacing of 1mtr c/c both ways on the existing structure .The loose cementitious particles are removed using a air blower to clean the holes.Shear Keys of dia 10mm cut from HYSD rebars are anchored into these holes of depth 75mm and bent out to an equal length of 75mm using Resin Anchor Grout complete all as per manufacturer instructions and directed by the Engr-in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
40
-
-
M&L for Providing & executing injection/pressure grouting in the cracks in the parent concrete by fixing PVC/Aluminium nipples at 150mm to 200mm distance or specified distances as per design and detailed specifications. Pressure grouting using low viscous epoxy grout. Moisture insensitive epoxy resin injection material supplied in 1.5 Litre pack which can grout gaps ranging from 0.25mm to 9mm, having mix density 1060 Kg/m3, compressive strength 60 N/mm2, Tensile Strength 20 N/mm2, Flutural strength 45 N/mm2. Pressure grouting shall be carried out after surface preperations includes fixing nipples and filling cracks with epoxy mortar one day before grouting, injecting low viscous grout mechanically about pressure 3.5-7.0 Kg/Cm2, removing nipple after grouting and sealing with epoxy mortar etc complete as directed by Engr - in - Charge. Payment shall be made on actual grout consumed. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
12
-
-
M&L for micro concrete to existing concrete structure including proper tight leak proof shuttering SPL polimer modified cementitious ,low permeable'free flow 'non shrink 'self compacting micro concrete shall be grade M70 as per recommended w/c ratio and pouring as per the required thickness complete all as per manufacturer instructions and directed by Engr- in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
1
-
-
Dismantling boarding, any description, fixed in any position with nails, complete all as specified.
140
-
-
Supply and fix false ceiling with powder coated exposed GI grip suspension system (E-grip T-2430 of equivalent load carrying capacity with mid span deffection not exceeding 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long, cross tee 1200mm/600mm long wall angle. The main runners to be placed @ 1200mm, the cross tee 1200mm will be inserted in the pre cut slots of main runner at a regular interval of 600mm from a modular grid of 1200mm X 600mm. Additional cross less of 600mm shall be placed perpendicular to the cross tee 1200mm long to finally from a grip of 600mm X 600mm. Grip of modular size 600mm X 600mm shall be supported by 6mm dia GI wire from purlins/soffit with and including 6mm thick high pressure steam cured non asbestos fiber and fixed complete all as specified and as directed.
200
-
-
S&F for ceiling boards 600x600x15mm in size, fixed in snap grid false ceiling frame work of approved colour, type complete fixed in position all as specified and directed. Make : Armstrong Optra RH95/ FG Classic or Equivalent
200
-
-
M& L for Post construction Anti termite treatment by chemical emulsion (Imidacloprid 30.5 SC) as approved by IS 6313( part 3) : 2013 to Ground floor buildings adhering to following specifications:
a) For internal area drill holes of 12-mm dia at 300 cms C/C along the inner junction of wall and floor in the entire premise. Water based chemical emulsion will be injected under pressure into these holes with dosage until refusal or maximum up to 1 Lit per hole. Minimum 400 ml chemical emulsion needs to be fill per hole.
b) For external area drill holes of 12-mm dia at 300 mm C/C along the external junction of wall and floor in the entire premise. Water based chemical emulsion will be injected under pressure into these holes with dosage of 2.25 ltrs per rm.
c) All drilled holes to be sealed with white cement and matched with surrounding wall finishes.
d) Treatment to wooden fixtures : At point of contact of wood work by chemical emulision (in oil or kerosene based solution) @ 0.50 lt/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm center to centre and sealing the smae to match existing finish.
e) Treatment to termite tubes : Visible shelter mud tubes will be removed and the infested area treated with water based chemical emulsion. All the drilled holes will be sealed and made food using cement. (f) Treatment to be done by specialist agency licensed by IPCA and approved by Engr-in-Charge. Specialist agency need to given written warranty for 5 years with yearly inspection and contact details to be displayed on board for attendance of complaint. Note : plinth area of the building will be measured
Specialist agency : PCI, Elite corporation, paragon pesticides or IPCA licensed approved by GE
250
-
-
Taking down carefully point wiring and removing from site such as (Light,fan socket or power) Complete including fitting and fixtures,fan regulators switch boards,switches,ceiling rose's lamp holder from existing batten PVC conduit/steel conduit wiring complete excluding light fittings and fans all as specified and making good to the disturbed surfaces to match with existing ,complete all as specified and as directed
247
-
-
M & L for point wiring complete for light/ fan on independent /combine board with cable 1.5 sqmm (Nominal area) FRLSH PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC casing & caping , hooks , elbows, juction covers and junction boxes , after cutting in wall and sinking's for modular metal flush boxes suitable length and Min 1.6 mm thickness, Min 51 mm depth for mounting, switches, sockets,fan regulator with modular cover plate with frame and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth continuity conductor along with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switch and connected to common earth dolly, complete all as specified and direced.
146
-
-
All as per Srl item No -85.00 here in before but for one socket outlet 5/6 amp on independent board complete all as specified and directed.
32
-
-
All as per Srl item No -85.00 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed.
23
-
-
All as per Srl item No. 85.00 here in before but for one switch socket combinationt 6 pin 5/ 15 Amps on independent board with copper conductor 2.5 Sqmm complete all as specified and directed.
41
-
-
All as Srl item No. 85.00 here in before but for one light point controlled by two 2 ways switches complete all as specified and directed.
3
-
-
All as Srl item No. 85.00 here in before but for call bell point complete all as specified and directed.
2
-
-
S & F in replacement modular switch 5/6 Amps single pole one way,one module including modular cover plate with frame and metal flush box complete all as specified and directed
201
-
-
S & F in replacement modular switch 15/16 Amps single pole one way,one module including modular cover plate with frame and metal flush box complete all as specified and directed
41
-
-
S & F in replacement modular socket 2/3 pin, type 5/6 Amps 5 in 1 flush type including modular cover plate and metal flush box with frame complete all as specified and directed
55
-
-
S & F in replacement modular socket 2/3 Pin, 6/16 Amps flush type including modular cover plate with frame and metal flush box complete all as specified and directed
41
-
-
S & F modular switch 5/6 Amps single pole two ways including modular cover plate with frame and metal flush box complete all as specified and directed
6
-
-
Supply and fix in replacement industrial socket metal clad plug and socket with MCBs single pole 20 Amp complte all as specified and directed
10
-
-
S&F modular bell push 5 Amp complete including modular cover plate with frame and metal flush box complete all as specified and directed
2
-
-
S & F modular stepped type, fan regulator not less than 120 watt for ceiling fan 1200/1400mm sweep complete including modular cover plate with frame and metal flush box complete all as specified and directed.
14
-
-
S&F Buzzer AC 230 single poleVolt ding dong type complete all as specified and directed
2
-
-
S & F ceiling rose surface bakelite three terminals complete all as specified and directed
102
-
-
Taking down carefully existing serviceable LED Tubelight/ bulkhead/ security light/ recess mount fitting of any size and refixing the same to respective location after carrying out cleaning all the components of fittings, including replacement of nuts, bolts and connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connectorcomplete all as specified and directed.
20
-
-
S & F in replacement LED Tubelight fitting with aliminium housing and integrated electronic driver, 20 watt having input voltage AC90-300V, 50 Hz , 6500K,surge protection min 4 KVA and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed.
22
-
-
Supply and fixing LED street light fitting 35 Watt 230 V AC surge protection 10 KVA outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.& Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 1 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed.
5
-
-
S&F in replacement LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.all as specified and directed.
24
-
-
Supply and fixing round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size completeall as specified and directed .
24
-
-
S & F in replacement LED Water tight bulk head fitting 10 W,comprision of connector galvanised cast iron back plate,weather proof enamelled gallery ,glass well,and including 10 watt LED all as specified and directed.
9
-
-
S & F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified.
7
-
-
S & F in replacement angle holder insulated body with back plate for conduit fittings complete all as specified and directed.
15
-
-
S&F LED lamp 9W for angle holder complete all as specified and directed
15
-
-
S & F in replacement for Sub Main wiring with two single core 6 Sqmm PVC insulated FRLSH multistranded flexible copper conductor cable 660/1100 volts grade drawn in through flexible non metallic PVC casing caping conduit with and including PVC insulated 6 Sqmm multi strand copper conductor as continuous earth wire in green colour connected to common earth dolly ,complete all as specified and as directed (Note :- Two length of 6 Sqmm cable and one length of 6 Sqmm earth cable along with PVC casing caping will be measured as one running length
120
-
-
S & F in replacement for Sub Main wiring with two single core 4 Sqmm PVC insulated FRLSH multistranded flexible copper conductor cable 660/1100 volts grade drawn in through flexible non metallic PVC casing caping conduit with and including PVC insulated 4 Sqmm multi strand copper conductor as continuous earth wire in green colour connected to common earth dolly ,complete all as specified and as directed ( Note :- Two length of 4 Sqmm cable and one length of 4 Sqmm earth cable along with PVC casing caping will be measured as one running length
145
-
-
S & F in replacement for Sub Main wiring with two single core 2.5 Sqmm PVC insulated FRLSH multistranded flexible copper conductor cable 660/1100 volts grade drawn in through flexible non metallic PVC casing caping conduit with and including PVC insulated 2.5 Sqmm multi strand copper conductor as continuous earth wire in green colour connected to common earth dolly ,complete all as specified and as directed Note :- Two length of 2.5 Sqmm cable and one length of 2.5 Sqmm earth cable along with PVC casing caping will be measured as one running length
55
-
-
S & F in replacement sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted TP & N 6 ways, 415 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof, IP42 suitable for incorporation MCBs and isolators etc including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed.
2
-
-
S & F in replacement sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 12 ways, 240 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof IP 42 suitable for incorporation MCBs and isolators etc including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed.
3
-
-
S & F in replacement MCB ‘B’ series type suitable for 415 volts, 10 KA, AC supply 40 to 100 Amps, triple pole and neutral (TPN) with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
2
-
-
S & F in replacement MCB ‘B’ series type suitable for 240 volts, AC supply 6 to 32 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
3
-
-
S & F in replacement MCB ‘B’ series type suitable for 240 volts,10 KA, AC supply 6 to 32 Amps , single pole (SP) with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
66
-
-
Material and Labour for Earthing in repair complete with copper plate 60cm×60cm ×3.15mm thick electrode, burried directly in ground ( earth pit not less than 2.25 mtrs below ground level) with top edge of the plate not less than 1.5 mtr normal ground level, connected to 20×3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel as shown in electrical plate No 3 of MES SSR Part-I 2009 connected to earthing test point by means of copper Strip of size 20x3 mm including earthwork, PCC chamber, CI cover, GI pipe protection for strip and watering pipe, funnel, mesh etc all as required at site and all as directed. Note: (i). 7.5 RM Copper strip in deemed to be included in quoted rates beyond 7.5 RM strip shall be measured and paid separately. (ii). Earth resistance of earth pit should be less than 1.0 Ohms. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (iii) Rate quoted by the tenderer is deemed to include for salt & Charcoal upto & above 450 mm top of earthing plate,testing complete all as specified and directed
2
-
-
Material and Labour for 20×3mm copper strip with suitable GI pipe etc from test terminal block to earth pit complete all as specified and directed.
25
-
-
Disconnecting electric connection and taking down carefully serviceable ceiling fans, exhaust fan, wall fan and keep in safe custudy. After the building repair work or as directed refixing /hanging the ceiling fan including electric connection with and including new flexible sheathed copper wire 3 core from ceiling rose/connector to fan connector, including in replacement new nut bolts, rubber reel, capacitor 2.5mfd, machine screws and split pins etc including painting the ceiling fan complete body with blades, canopies, down rod etc. with synthetic enamel paint by spray gun after scraping down old paint in colour as directed complete all as specified and as directed
15
-
-
Material and labour for servicing of Split type ACs of any size/capacity by disconnecting the electrical/water connections, taking out from its position, cleaning the external dirt & dust, cleaning air filter, condenser,washing by water jet,drying by air blower,checking all electrical connections and refixing in existing position and testing, complete all as directed
9
-
-
Supply and fix electronic meter three phase temper proof LCD display with polycarbonate cover 415 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as directed
1
-
-
S&F Heavy duty metal body exahust fan of 300mm sweep ,240 volt,copper winding, complete with louvers and shutter and mounted in suitable opening arrangement in wall and connecting up including 3 core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2mm from ceiling rose to fan complete including breaking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to distubed wall in cement mortar (1 :4) white washing matching with existing colour etc complete all as directed.
4
-
-
S&F ceiling fans AC single phase 230/240 V of size 1200 mm sweep without regulator having Min air delivery 210 CFM with service value 6.00 BEE 5 star rated with brushless direct current motor (BLDC) complete with electrical connection providing three core round flexible copper conducter cable of suitable size complete all as specified and directed by Engineer-in-charge.
5
-
-
S&F wall mounting fans for 230 volts single phase 400 mm sweep compl;ete all as specified and directed
6
-
-
Dismantling and Taking down L.T. under ground armored PVC/XLPE insulated and PVC/XLPE sheeted heavy duty 1100 Volts grade under ground cable of any size complete all as specified and directed.
120
-
-
Taking out serviceable unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm during excation of trenches and relaying after cable laying in trenches all as specified and directed
600
-
-
Excavation in trenches not exceeding 1.5 m wide and not exe 1.5 M in depth and getting out in hard/dense soil complete all as specified and directed .
27
-
-
Returning filling in including spreading leveling, watering and well ramming in layers not exe 25 cm each layer complete all as specified and directed.
18
-
-
Removing excavated material to a distance not exe 50 M and depositing where directed not exceeding 1.50 M above the starting point complete all as specified and directed.
9
-
-
Supply and spreading in trenches dry crushed Stone sand for cable protection and punning down gently by hand all as specified.
8
-
-
Supply and laying unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 ISI marked flat size 250x150x40 mm laid in trenches as specified and as directed.
600
-
-
Supply and lay jointing and testing and commissioning in replacement of 35 Sqmm x 3.5 core XLPE insulated, screened , PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed
120
-
-
Supply and fix 3 pin telephone socket RJ 11 with metal flush box having holes for 20 mm conduit entry for telephone connection all as specified and directed.
2
-
-
S & F Rigid non-metallic PVC conduit 20 mm dia inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.
70
-
-
Supply and lay in repair, GI pipe 50 mm light grade for cable protection in walls trenches or any situation including clamp nut bolt etc complete all as specified and directed
25
-
-
Supply & fixing in replacement of meter box enclosures size (0.9 mX0.9 mX0.25m) made of Polycarbonate shall have Opaque base & Transparent cover,should be weather/ vermin proof, anti-acid, anti corrosive, UV resistance in accordance with IEC 61439-1, Fire retardant and Self-extinguishing accordance with IEC 6069 5-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960° in accordance with 60695-2-11. Degree of protection against mechanical load should be IK 08 (5 Joule) in accordance with IEC 62262, IP 65 in accordance with IEC 60529 & IEC60439-1, should have Dielectric Properties, RoHS compliant & Halogen free.The meter boxes should be modular and compartmentalized in construction with opaque and transparent cover, properly tightened to base with thermoplastic/SS304 screws /Nuts & bolts having sealing gasket made of extruded silicon rubber to withstand adverse weather effects. The depth of modular meter enclosures should be above 200mm for air circulation & to minimize temp rise during peak Indian summer ambient temperature of 45+ Deg C, lock arrangement ,transperent glass for meter reading, suitable for fixing Electric meter & TPN DB box including taking down existing electric meters , refixing them with four single core PVC copper conductor unsheathed wire multistranded 6 sqmm,properly painting on meter box complete and fixing in wall with suitable cutting,cement work etc complete all as specified and directed.
2
-
-
M&L for steel water tubing in repair medium grade of size 25 mm bore with all fittings laid in trenches or fixed to wall or floor.complete all as specified and directed
60
-
-
M& L Cutting existing steel tubing for alterations or additions 40m or 50 mm size , Add if necessarily done in position without taking down.
2
-
-
S & F Gun-metal, globe or gate valves 25 mm, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed
4
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%