Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Water Storage And Supply
Electrical Works
Eprocure
Opening Date15 Feb 2025
Closing Soon13 Mar 2025
Tender Amount₹ 48,46,300
Costs
EMD
₹ 96,926Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Addition Alteration Of 3 Phase Lt Supply Db At Various Places In Imsc Including Repair Of Roof Treatment Water Proofing Of Imsc Building (p-63) Imsc (dhanush)
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_698093_1Tender No
8396Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M&L for applying oil bound primer @ 0.40 Litre/Sqm manufactured by the same agency as that of APP with density of 0.87 to 0.89 Kg/Litre at 25 degree cesius on the prepared dry roof surface and provide and lay 4mm thick APP modifed water proofing membrane reinforced with non-wooven polyster matt with physical properties as given in particular specification. The laying shall got be done through authorized applicator of manufacturer as specified in particular specifications. Provide over the membrane as prescribed by manufacturer of membrane including Ten years guarantee on prescribed form complete all as per particular specification , manufacturers instructions and as directed by Engineer-in-Charge. (Note : Rate inclusive of taking down and re fixing of water tank and GI pipes and existing lightning arrestor system including provision of new PCC block,water tank of same capacity and GI pipes for damaged PCC block,water tanks and GI pipes complete as directed by Engineer-in-charge)
2500
-
-
... More
M&L for brushing neat cement slurry with 3Kg of cement per square metre all as specified and directed.
2500
-
-
... More
M&L for rendering 10 mm thick cement plaster in CM (1:3) on roof top surface finished even and fair including WPC by weight of 3% of total cement content complete all as specified and as directed.
(Note : WPC will be measured separately)
2500
-
-
... More
Supply only integral water proofing compound.
630.75
-
-
... More
M&L for cement concrete tiles 25CmX25CmX22 mm thick, machine pressed,(with grey cement & no pigments), set jointed and pointed in neat cement slurry in floors over and including 15 mm thick bedding layers in CM 1:3. all as specified & directed by engn-in-charge
2310
-
-
... More
Taking down eaves gutters and rainwater pipes( any size or pattern) , including all fittings, heads, shoes, bends , swan necks, etc, removal to store (measured overall as fixed along the centre line over fittings and accessories).
70
-
-
... More
S &F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
70
-
-
... More
S&F for PVC (SWR) bends any radius 110mm bore complete all as specified and as directed
16
-
-
... More
Taking up and down 15 mm bore GI tubing and connection including cleaning for re-fixing or removing to store complete all as specified and directed.
150
-
-
... More
_Ditto_ all as per Sl item No. 12 here in before but 20 mm bore complete all as specified and directed.
40
-
-
... More
_Ditto_ all as per Sl item No. 12 here in before but 25 mm or 32 mm bore complete all as specified and directed.
20
-
-
... More
S & F tubes medium grade galvanised with all fitting and fixed complete to walls and ceiling or laid in floors 15 mm bore of pipe complete all as specified and directed.
150
-
-
... More
_Ditto_ all as per Sl item No. 15 here in before but 20 mm bore of pipe
40
-
-
... More
_Ditto_ all as per Sl item No. 15 here in before but 25 mm bore of pipe
20
-
-
... More
Dismantling of water tank capacity .exc 2000 ltrs and removing to store all as specified in SSR Part I
2
-
-
... More
S&F rotational moulded polythene water storage tank of 5000 ltrs capacity (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I
2
-
-
... More
M&L for Cutting chases, pinning in.Stone concrete block or slabe, bricks wall making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring or water proofing membrane,etc., and making good, cutting not exc 10 cm girth all as specified & directed by engn-in-charge
228
-
-
... More
Supply, install, testing and commissioning of LT Feeder Pillar CPRI Approved mounted on angle iron frame of 40x40x5 mm and grouted on floor,cubical outdoor type, with both side opening and suitable for site(or as per existing site) with suitable fixing of all breakers and controls for 415V, 3 phase, made of 3 mm thick CRCA sheet weather, vermin proof factroy fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 800 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections Panel and fixing/connecting in new insalled panel with provisions of thimble/lugs and necessary farmework and PCC foundation including shifting of existing of LT Panel if any making arrengement for fixing of panel and making good to disturbed surface as directed comprising of the following :-
1
-
-
... More
(b) MCCB 400 Amps, 36 KA,(Incoming) FP - 01 Nos.
-
-
-
... More
(d) MCCB 250 Amps, 36 KA FP(Outgoing) - 02 Nos.
-
-
-
... More
(e) MCCB 200 Amps, 25 KA FP(outgoing) - 01 Nos.
-
-
-
... More
(f) MCCB 160 Amps, 16 KA, FP(outgoing) - 02 Nos.
-
-
-
... More
(f) MCB 63 Amps, DP(outgoing) - 05 Nos.
-
-
-
... More
(g) conrol panel wiring with 2.5 sq mm multistranded, pvc insulated copper conductor cable between voltmeter, Am meter, and their selector switch complete with CTs of ratio 400/5A- 2 Nos,320/5 A- 2 Nos , 250/5 A- 2 Nos ,200/5 A - 2 Nos , 160/5 A - 2 Nos , voltmeter flush pattern type 96 mm square dial -1 nos, Am- meter digital CT operated 96 mm sqare dial flush pattern type -10 Nos, indication lamp for 3 phase and control fuses-3 Nos complete .
-
-
-
... More
(h) Aluminium bus bar 800 Amps for phase & 800 Amps for neutral complete with bus bar insulator,nuts & bolts complete.
-
-
-
... More
(j) Power panel wiring between bus bar to MCCB of different capacity with PVC insulated multistranded copper cable , single core ,1100 volts grade of appropriate size complete with copper lugs
-
-
-
... More
Supply, install, testing and commissioning of LT Panel CPRI Approved mounted on angle iron frame 40x40x5 mm grouted on floor,cubical outdoor type, with both side opening suitable at site or suitable fixing of all breakers and controls, for 415V, 3 phase, made of 3 mm thick CRCA sheet weather, vermin proof factroy fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 800 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections Panel and fixing/connecting in new insalled panel with provisions of thimble/lugs and necessary farmework and PCC foundation including shifting of existing (old) LT Panel, if any, making arrengement for fixing of panel and making good to disturbed surface as directed comprising of the following :-
1
-
-
... More
(a) MCCB 400 Amps, 36 KA, FP - 01 Nos (incoming)
-
-
-
... More
(b) MCCB 250 Amps, 25 KA, TP - 02 Nos (outgoing)
-
-
-
... More
(c) MCCB 160 Amps, 25 KA, TP - 02 Nos (outgoing)
-
-
-
... More
(c) MCCB 100 Amps, 25 KA, TP - 02 Nos (outgoing)
-
-
-
... More
(d) MCCB 63 Amps, 16 KA, TP - 02 Nos (outgoing)
-
-
-
... More
(e) MCB DP 40 Amps - 06 Nos (outgoing)
-
-
-
... More
(f) Control panel wiring with 2.5 sq mm multistranded, pvc insulated copper conductor cable between voltmeter, Am meter, and their selector switch complete with CTs of ratio 630/5 Amps- 2 no,400/5A- 3 Nos,320/5 A- 4 Nos , 250/5 A- 3 Nos ,200/5 A - 3 Nos , 160/5 A - 2 Nos , voltmeter flush pattern type 96 mm square dial -1 nos, Am- meter digital CT operated 96 mm sqare dial flush pattern type -17 Nos, indication lamp for 3 phase and control fuses-3 Nos complete .
-
-
-
... More
(g) Aluminium bus bar 800 Amps for phase & 400 Amps for neutral complete with bus bar insulator,nuts & bolts complete.
-
-
-
... More
(h) Power panel wiring between bus bar to MCCB of different capacity with PVC insulated multistranded copper cable , single core ,1100 volts grade of appropriate size complete with copper lugs
-
-
-
... More
(h) Aluminum bus bar 800 Amps for phase & 600 Amps for neutral complete with bus bar insulator,nuts & bolts complete.
-
-
-
... More
(j) Power panel wiring between bus bar to MCCB of different capacity with PVC insulated multistranded copper cable , single core ,1100 volts grade of appropriate size complete with copper lugs
-
-
-
... More
Supply, install, testing and commissioning of LT Panel CPRI Approved mounted on angle iron frame 40x40x5 mm grouted on floor,cubical outdoor type, with both side opening Minimum size 1200x1200x 600 mm or suitable fixing of all breakers and controls, for 415V, 3 phase, made of 3 mm thick CRCA sheet weather, vermin proof factroy fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 800 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections Panel and fixing/connecting in new insalled panel with provisions of thimble/lugs and necessary farmework and PCC foundation including shifting of existing (old) LT Panel, if any, making arrengement for fixing of panel and making good to disturbed surface as directed comprising of the following :-
1
-
-
... More
(a) MCCB 400 Amps, 36 KA, FP - 01 Nos( Incoming)
-
-
-
... More
(b) MCCB 250 Amps, 25 KA, TP - 02 Nos (outgoing)
-
-
-
... More
(b) MCCB 160 Amps, 25 KA, TP - 03 Nos (outgoing)
-
-
-
... More
(c) MCCB 100 Amps, 25 KA TP - 02 Nos (outgoing)
-
-
-
... More
(d) MCCB 63 Amps, 16 KA TP - 02 Nos (outgoing)
-
-
-
... More
(e) MCB DP 40 Amps - 05 Nos (outgoing)
-
-
-
... More
(f) Control panel wiring with 2.5 sq mm multistranded, pvc insulated copper conductor cable between voltmeter, Am meter, and their selector switch complete with CTs of ratio 630/5 Amps- 2 no,400/5A- 3 Nos,320/5 A- 4 Nos , 250/5 A- 3 Nos ,200/5 A - 3 Nos , 160/5 A - 2 Nos , voltmeter flush pattern type 96 mm square dial -1 nos, Am- meter digital CT operated 96 mm sqare dial flush pattern type -17 Nos, indication lamp for 3 phase and control fuses-3 Nos complete .
-
-
-
... More
(g) Aluminium bus bar 800 Amps for phase & 400 Amps for neutral complete with bus bar insulator,nuts & bolts complete.
-
-
-
... More
(h) Power panel wiring between bus bar to MCCB of different capacity with PVC insulated multistranded copper cable , single core ,1100 volts grade of appropriate size complete with copper lugs
-
-
-
... More
Supply & fix in repair MCB DB, TPN 8 way vertical type, 415 V with 200 Amps rated bus bar and double door connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed, comprising of the following : - (a) MCCB 3 Pole, 415 V fixed type, 160 Amps with breaking capacity 25 KA-01 Nos (incoming) (b) MCB TP 63 Amps, 10KA - 06 Nos (B Series) (Outgoing) (c) MCB SP 40 Amps, 10KA - 06 Nos (B Series) (Outgoing)
5
-
-
... More
Supply and fix LED Flood Light for indoor badminton courts, of wattage 80W with input voltage 230V and 50HZs freq.,9600luminius flux,120lm/W luminious efficiency,with colous temperature range 4000K to 5000K ,Colous rendering index 70,system current Amp 0.33A,Power Factor0.95,THD10%,ingress protection IP66, Impact protection IK07, with proper beam angle which focuses the directly to the court with bright, natural light that enhances visibility and reduces eye strain,glare Free and Effective heat dissipation is essential for maintaining the performance and longevity of LED lights designed with efficient cooling systems that prevent overheating the height of the fixtures should be appropriate for the ceiling height to achieve optimal illumination including all nut and bolts and steel rod required for hanging the light in the appropirate hight for connecting the light with bracket all as specified and directed by Engr-in-Charge.(Make-: Praze F 96L WH NB-A5 TG SD of bajaj or equivalent in Havells,crompton.)
27
-
-
... More
M&L for Earthing with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, burried directely in ground (earth pit not less than 2.5 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 32 x 6 mm with the help of bolts, nuts, check nuts and washers of galvanised iron or steel, including necessary excavation, PCC 1:3:6 type D2 and PCC cover 1:2:4 type B1 weatering arrangement with GI pipe funnel, jali, complete all as specified and shown including connection to the earthing test point and testing on completion.
8
-
-
... More
S & F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6 mm dia galvanised iron strips complete all as specified and directed by Engr - in - Charge.
139
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%