Military Engineer Services Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 Jan 2025
Closing Soon18 Feb 2025
Tender Amount₹ 48,50,000 
Notes
Download

Costs

Summary

Repair And Maintainance And Replacement Of Defective Items Of Earthing Lighting Protection And Misc Items At Wsa 2w Lt Distribution System At Wsa 2w Internal Electric Supply System In Viman Nagar Chandan Nagar Akash Nagar And Flame Proof Light F

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S&F sub main wiring with two runs of single core 2.5 Sq mm FRLSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 2.5 Sq mm single core Flame retardan PVC insulated unsheathed multi stranded copper conductor green colour cable for continuous earthing complete in & including PVC casing & caping with all fttiing & fixtures all as directed and specified. (Note:- Two runs of 2.5 Sqmm copper cable & one run of 2.5 sqmm copper cable including PVC casing & caping shall be mesured and paid as one length)

240

-

-

... More
S&F sub main wiring with two runs of single core 4.0 Sq mm FRLSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 4 Sq mm single core Flame retardan PVC insulated unsheathed multi stranded copper conductor green colour cable for continuous earthing complete in & including PVC casing & caping with all fttiing & fixtures all as directed and specified. (Note:- Two runs of 4 Sqmm copper cable & one run of 4 sqmm copper cable including PVC casing & caping shall be mesured and paid as one length)

200

-

-

... More
S&F sub main wiring with two runs of single core 6.0Sq mm FRLSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 6.0 Sq mm single core FRLSH PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in & including casing & caping all as directed and specified . ( Note:- Two runs of 6 Sqmm copper cable & one run of 6 sqmm copper cable including PVC casing & caping shall be measured & paid as one length )

180

-

-

... More
S&F sub main wiring with two runs of single core 10.0Sq mm FRLSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 10.0 Sq mm single core FRLSH PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in & including casing & caping all as directed and specified . ( Note:-Two runs of 10 Sqmm copper cable & one run of 10 sqmm copper cable including PVC casing & caping shall be measured & paid as one length )

80

-

-

... More
S&F Sub main wiring with 4 X 4 sqmm single core cable PVC insulated unsheathed of copper multi strandard conductor cable , 1100 votls grade drawn in PVC casing caping and including PVC casing caping and insulated 1X 4 sqmm unsheathed multistranded FR-LS copper conductor cable for earth continuity and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. (Note:- 4 lengths of 4 Sqmm & 1 length of 4 sqmm cable and PVC casing caping will be measured as one length).

100

-

-

... More
S&F Sub main wiring with 4 X 6 sqmm single core cable PVC insulated unsheathed of copper multi strandard conductor cable , 1100 votls grade drawn in PVC casing caping and including PVC casing caping and insulated 1X 6 sqmm unsheathed multistranded FR-LS copper conductor cable for earth continuity and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. (Note:- 4 lengths of 6 Sqmm & 1 length of 6 sqmm cable and PVC casing caping will be measured as one length).

100

-

-

... More
S&F Sub main wiring with 4 X 10 sqmm single core cable PVC insulated unsheathed of copper multi strandard conductor cable , 1100 votls grade drawn in PVC casing caping and including PVC casing caping and insulated 1X 10 sqmm unsheathed multistranded FR-LS copper conductor cable for earth continuity and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. (Note:- 4 lengths of 10 Sqmm & 1 length of 10 sqmm cable and PVC casing caping will be measured as one length).

60

-

-

... More
Supply and fix in replacement defective switch piano flush type 5 Amp one way ISI Marked, including

900

-

-

... More
Supply and fix in replacement defective Socket out let 3 pin 5 Amp ISI Marked

300

-

-

... More
Supply and fix in replacement defective switch socket combination 5 A, 3 Pin, flush type ISI Marked

150

-

-

... More
Supply and fix in replacement defective switch socket combination 5 / 16 A, 2 in 1, flush type ISI Marked.

250

-

-

... More
Supply and fix in replacement defective switch piano flush type 15 Amps ISI Marked complete all as specified and directed.

150

-

-

... More
Supply and fix in replacement defective Socket out let 2 in 1, 3 pin 5 and 15 Amps ISI Marked complete all as specified and directed.

180

-

-

... More
Supply and fix in replacement defective switch piano flush type 5 Amp two way ISI Marked

50

-

-

... More
Supply and fix in replacement defective Piano switch bell push type switch 5 A ISI Marked

250

-

-

... More
Supply and fix in replacement defective bell electric 230V single pole ding dong type complete as directed.

240

-

-

... More
S/F Fan in replacement defective Regulator electronic step type 100 W, 230V two Module complete as directed

280

-

-

... More
Note for item No. 11 to 20: These items includes cost of openingof existing switch board/ Box, unscrewing of defective switches, sockets, regulator, bell push and replacing with new one & includes replacing of burnt wire inside the switch box

-

-

-

... More
S&F in replacement angle / batten holder 230V insulated body with back plate for batten fittings ISI Marked

360

-

-

... More
Supply and fix in replacement ceiling rose 230V surface type bakelite / PVC three terminal 65 x 50mm ISI Marked

500

-

-

... More
Taking down existing light fitting and Supply and fix high quality indoor Surface and wall mounted batten suitable for 20 Watt T8 Tube rod 4 feet long , including LED retrofit Tube rod 20 Watt T8 Tube rod 4 feet long 6000K colour temperature with extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser with industrial grade heavy duty driver having THD10%. complete with all accessories internally pre-wired batten and including PVC square box 2 Nos for mounting of batten and connecting up with three core 0.5 Sqmm flexible copper conductor cable ceiling rose to fitting terminal.

1700

-

-

... More
Taking down existing light fitting and Supply and fixing LED mirror light fitting 10 Watt 230V 2 feet long including electrical connections complete as directed.

70

-

-

... More
Taking down existing light fitting and S & F Recessed mounted LED down lighter with electronic driver 21 Watt 230V powder coated aluminium housing with integrated electronic driver complete Iincluding making all nacessary arragement to fix and connection as required on site complete all as specified and directed.

15

-

-

... More
Taking down existing light fitting and S & F Recessed mounted LED down lighter with electronic driver 18 Watt 230V complete Iincluding making all nacessary arragement to fix and connection as required on site complete all as specified and directed.

15

-

-

... More
Taking down existing light fitting and Supply and fix in replacement electronic driver for recess mounted LED panel fitting 36 Watt 230V 6000K suitable for 2x2 grid in roof including electric connections and testing as directed.

38

-

-

... More
Taking down existing High bay/ Midbay/ flood light fitting from wall/ building/ shed/ ceiling of height upto 12 Mtrs for repairs and Supply and fix in replacement electronic driver for light fitting of 120 watt to 180 watt including electric connections and refixing the light fitting to its original position and testing as complete all as directed by Engr-in-Charge.

30

-

-

... More
Taking down existing light fitting and Supply and fix Energy efficient recess mounted LED panel fitting 36 Watt suitable for 2x2 grid in white colour with high quality diffuser for uniform light & high Efficiency. Made from CRCA sheet, Pre-coated white color. Separate replaceable electronic driver, lumen constant of 6000K colour temperature with current electronic connections as directed including 2 core wire upto ceiling rose complete.

24

-

-

... More
Taking down existing light fitting and Supply & fix LED street light fitting Energy saving and environmental friendly long life LED street light fittings 45 Watt made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded Toughened having IP65 protection and Impact resistance of IK07 with 10KV Built-in Surge Protection Device The light fittings shall be fixed on pole/bldg with complete all as specified and directed.

15

-

-

... More
S&F Vertical double door Distribution board TPN 4 way with busbar consisting of MCCB. 100A 10KA - 1 NO complete including connecting LT cable and outgoing submain wiring etc and testing complete all as specified and directed by Engr-In-charge.

6

-

-

... More
Supply and fix sheet metal enclosure MCB DB double door SPN 12 way 230 V with neutral link and connecting to wiring complete all as specified and directed by Engr-In-charge.

20

-

-

... More
Supply and fix sheet metal enclosure MCB DB double door SPN 8 way 230 V with neutral link and connecting to wiring complete all as specified and directed by Engr-In-charge.

25

-

-

... More
Supply and fix sheet metal enclosure MCB DB double door SPN 4 way 230 V with neutral link andand connecting to wiring complete all as specified and directed by Engr-In-charge.

12

-

-

... More
Supply and fix MCB SPN 240 V, 32 Amps. complete all as directed at site.

85

-

-

... More
Supply and fix MCB SP 240 V ,6 to 32 Amps complete all as directed at site.

450

-

-

... More
M/L for providing earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.00mm dia by means of bolts, nuts, checknuts & washers of GI or steel and connecting to earth dolly all as shown in electrical plate No. 3 of SSR Part I of 1991 & testing complete including 15mm dia light grade GI pipe upto 7.5mtr long, excavation in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, test box , funnel, wire mesh with GI watering pipe etc.

4

-

-

... More
Supply and fix in replacement capacitor 2.5 microfd /3.15 microfd

350

-

-

... More
Supply and fix In replacement capacitor 4 microfd

50

-

-

... More
Supply and fixing in replacement of Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket, one single pole 20 Amps, 240V MCB complaints complete all as specified and directed

15

-

-

... More
S & F Modular switch 1 way 6A, 1 module matching to as existing on site complete all as specified and directed.

25

-

-

... More
S & F Modular switch 1 way 16A, 1 module vmatching to as existing on site complete all as specified and directed.

8

-

-

... More
S & F Modular Bell push 1 module, 5 amp matching to as existing on site complete all as specified and directed.

3

-

-

... More
S & F Modular socket 6 A 2 module matching to as existing on site complete all as specified and directed.

12

-

-

... More
S & F Modular socket 16 A 2 module matching to as existing on site complete all as specified and directed.

8

-

-

... More
S & F Modular stepped Fan Regulator 120W 2 module matching to as existing on site complete all as specified and directed.

8

-

-

... More
Note for item No. 41-46 These items includes cost of openingof existing switch board/ Box, unscrewing of defective switches, sockets, regulator, bell push and replacing with new one.

-

-

-

... More
S & F in replacement modular cover plate with frame 4 module matching to as existing on site complete all as specified and directed.

5

-

-

... More
S & F in replacement modular cover plate with frame 6 module matching to as existing on site complete all as specified and directed.

5

-

-

... More
S & F in replacement modular cover plate with frame 8 module matching to as existing on site complete all as specified and directed.

5

-

-

... More
S & F in replacement modular cover plate with frame 3 module matching to as existing on site complete all as specified and directed.

12

-

-

... More
S & F in replacement PVC switch box for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep including screws, plastic plugs etc complete all as specified and directed.

100

-

-

... More
Ditto all as per Ser Item No. 51.00 above but 175 x 100 x 50 mm complete all as specified and directed.

60

-

-

... More
Ditto all as per Ser Item No. 51.00 above but 200 x 150 x 50 mm complete all as specified and directed.

50

-

-

... More
Ditto all as per Ser Item No. 51.00 above but 250 x 200 x 50 mm complete all as specified and directed.

25

-

-

... More
Taking down existing unserviceable PVC exhaust Fan (Fresh Air fan) from its position and refixing the same to its original position after testing complete all as specified and directed by Engr-In-Charge.

220

-

-

... More
Supply and fix in replacement exhaust fan blades made of sturdy Engineering plastic complete of sweep 300 mm complete all as specified and directed.

220

-

-

... More
Supply and fix in replacement PVC exhaust fan motor copper wound complete of sweep 300 mm complete all as specified and directed.

220

-

-

... More
Supply and fix in replacement exhaust fan louvers made of sturdy Engineering plastic complete of sweep 300 mm complete all as specified and directed.

220

-

-

... More
Supply and fix in replacement exhaust fan Frame rear and front made of sturdy Engineering plastic complete of sweep 300 mm complete all as specified and directed.

220

-

-

... More
Supply and fix in replacement 1.5 Micro Fd capacitor square shape suitable for PVC exhaust fan sturdy Engineering plastic complete of sweep 300 mm complete all as specified and directed.

220

-

-

... More
S & F PVC Casing & Capping of size 25 mm width with connected accessories such ass screws etc.

60

-

-

... More
Supply & fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core cables stranded conductor flat or circular 6 Sqmm complete all as specified and directed.

270

-

-

... More
Supply & fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core cables stranded conductor flat or circular 10 Sqmm complete all as specified and directed.

270

-

-

... More
Supply & replace 3 pin 15 Amps Plug Top 250 Volts heavy duty ISI Marked PVC complete all as specified and as directed.

80

-

-

... More
M&L for Attending E-N voltage complaints, checking the wiring circuit for attaining desired E-N voltage, including fine tuning isolation transformer connections , checking all incoming and outgoing circuits, cleaning and servicing of isolation transformer complete upto satisfaction of Engr-In-Charge. (Note : Any minor spare part found faulty during checking and cable lugs , minor wire pieces including cost of T&P, multimeter etc shall be included in quoted rates of this item)

8

-

-

... More
Supply and fix MCB TPN 415 V, 32 Amps 10 KA C Curve in DB complete all as directed at site.

5

-

-

... More
Supply and fix MCB TPN 415 V, 40 to 100 Amps 10 KA C Curve in DB complete all as directed at site.

5

-

-

... More
Supply and fix in replacement Metal clad plug top 20 Amps 230V rating with eath pin ISI marked in DB complete all as directed at site.

45

-

-

... More
Supply and fix in replacement Metal clad socket 20 Amps 230V rating with eath pin ISI marked in DB complete all as directed at site.

50

-

-

... More
Supply and fixing LED flood light 170 watt 230 V AC outdoor type made out of pressure die cast aluminium housing with toughened glass and high power LED and lenses with system efficacy = 110 LPW with IP 66 protection, with impact and corrosion resistant complete with driver and lamp. including clamp, bracket & GI pipe nut bolts including provision of 1.5 sqmm 3 core copper cable length upto 5 mtr complete all as specified and directed by Engr-In-charge.

5

-

-

... More
Taking down of old unsv HPSV/HPMV highbay light from ceiling installed at the height of 35-40ft and Supply and fixing in replacement of LED highbay light with PDC housing, integral driver, frame, toughened glass & IP 66 protection, 120 Watt, 220/215 Volt 50 Hz with surge protection and housed in pressure die cast and system lumen output should not be less than 120 lumen per watt complete including cradle and ege bolting and additional chain/clamps for mounting with not bolts all as specified and dircted by Engineer-in-Charge.

5

-

-

... More
Supply and fix in replacement of LED T-8 retro fit tube rod 4 feet long 18/20Watt 6000K 230V aluminum housing complete in existing T8 compatible batten or Flame proof light fitting , including taking down light fiiting, replacing tube rod, checking connections and testing before fixing of serviceable light fitting to its original position complete all as specified and directed by Engr-In-Charge.

200

-

-

... More
M& L for taking down carefully and refixing in position after repairs to existing flameproof DB with MCBs Complete by replacing existing all unserviceable MCBs with similar capacity, ON/OFF knob , levers, connector complete and make the existing DB serviceable all as directed incl making good disturbed surfacecomplete. Note : MCBs replaced shall be measured and paid separately under appropriate item of BOQ.

25

-

-

... More
M& L for taking down carefully and refixing in position after repairs to existing flameproof Rotary switch Complete by replacing existing all unserviceable parts such as rotary drum, ON/OFF knob , levers, connector complete and make the existing flame proof switch serviceable all as directed incl making good disturbed surfacecomplete.

50

-

-

... More
M/L for sub main wiring with two runs of single core 6.0Sq mm FRLSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 6.0 Sq mm single core FRLSH PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in existing PVC Conduit all as directed and specified . ( Note:- Two runs of 6 Sqmm copper cable & one run of 6 sqmm copper cable drawn in PVC conduit shall be measured & paid as one length )

130

-

-

... More
Note for Item No.1 to75 : (i) The contractor shall depute atleast 2 electrician and 2 helper for Viman Nagar/Chandan nagar Area, 2 electrician and 2 helper for NP Area and 1 electrician and 1 helper for Akash Nagar/509 Area on daily basis for rectification of complaints, Contractor shall ensure sufficient store is available for rectification of complaint the same day. Contactor/ rep of contractor shall submit daily feedback to JE or Power house incharge regarding each complaint. Contractor shall depute additional manpower if No. of complaint increases or direction from Engr-In-Charge is recieved for same. Note for item No 70 & 71: (i) The fittings shall be mounted on Sun-shelter/Hanger/shed of height up to 10 mtr (ii) All T & P required shall be deemed to be included in the quoted rate.

-

-

-

... More
Material and labour for Checking/ Testing of resistance value of any type of earth pits by disconnecting earth continuity conductor from test terminal block/panel/equipment at various location of AF Station Pune and reconnecting the earth continuity conductor after testing.Temporary earthing connection to be provided while testing.Earth tester will be provided by contractor. Earth tester must be calibrated. Earth test to be signed by Rep of contractor, Rep of MES and Rep of AF. Test reports to be submitted in triplicate complete all as specified and directed.

150

-

-

... More
M&L for supply, installation, testing and commissioning of pure copper pipe electrode earthing maintenance free earthing based on 6 mtr long copper pipe 76 mm dia(ID) with wall thickness of 3 mm, copper strip 32x 6 mm ( strip in pipe type electrode )and copper pipe electrode shall be filled with MFC for improvement of conductivity of electrode, 120 KGS approx of BFC shall be filled around the copper pipe elecrode . Rate included for testing,commisioning including checking of earth continuity and earth result complete all as specified and directed. Rate is included for boring of earthing in any type of soil/rock upto 200 mm bore.Continuity of good earth resistance shall maintained upto 1 year and testing will be carried out monthly by MES authority.Copper strip must be connected with copper pipe electrode and at other joints through brass nut bolt all as specified and directed.

5

-

-

... More
M&L for supply, installation, testing and commissioning of pure copper pipe electrode earthing maintenance free earthing based on 3 mtr long copper pipe 76 mm dia(ID) with wall thickness of 3 mm, copper strip 32x 6 mm ( strip in pipe type electrode )and pure copper pipe electrode shall be filled with MFC for improvement of conductivity of electrode, 60 KGS approx of BFC shall be filled around the copper pipe elecrode . Rate included for testing,commisioning including checking of earth continuity and earth result complete all as specified and directed. Rate is included for boring of earthing in any type of soil/rock upto 200 mm bore.Continuity of good earth resistance shall maintained upto 1 year and testing will be carried out monthly by MES authority.Copper strip must be connected with copper pipe electrode and at other joints through brass nut bolt complete all as specified and directed.

5

-

-

... More
S & F GI earth continuity conductor or main earthing lead of size 25X4 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc. as required complete all as specified and directed.

60

-

-

... More
S & F copper earth continuity conductor or main earthing lead of size 20x3 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc. as required complete all as specified and directed.

138

-

-

... More
Taking down carefully from roof / wall of the building loose / hanging / deshaped / GI strip/ aluminium strip / copper strips of any size & type including unserviceable insulators etc complete all as specified and directed.

512

-

-

... More
Refixing serviceable aluminium /Copper/Galvanised Iron strips of any size and fixing on porecelin insulators 'T' type placed not more than 50 cm apart & fixed with srews & nut bolts complete all as specified and directed. Note : M&L Porcelain insulators with nuts bolts and screws will measured and paid separately

254

-

-

... More
Supply & fix aluminium strips 25x3 mm on porceline insulator 'T' type not more than 50 cm apart complete all as specified and directed. Note: M&L Porcelain insulators with nuts bolts and screws will measured and paid separately

60

-

-

... More
S&F porcelian insulators with nut bolts / screws for fixing of copper / aluminium strips / GI strips on walls etc complete all as specified and directed.

100

-

-

... More
M&L for earthing chamber of size 450x450x300 mm depth outside & 250x250x300 mm depth of PCC (1:3:6) type C1 complete all as specified and directed.

17

-

-

... More
S&F in repair of earthing pit cover 50 mm thick precast slab of RCC 1:2:4 type B1, reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm incl 6 mm dia bar handle complete all as specified and directed.

14

-

-

... More
Material and labour for welding in joints of GI Strip any size and after welding testing and commessioning will be carried out and result will be recorreced complete all as specified and directed

30

-

-

... More
Material and labour for brezing in joints of Copper Strip any size and after brezing testing and commessioning will be carried out and result will be recorreced complete all as specified and directed

20

-

-

... More
Supply and fixing of of magnesium sulphate for earthing complete all as specified and directed.

5

-

-

... More
Material and labour for disconnecting serviceable LT cable of any size and core from LT poles and terminate it into LT panel using suitable aluminium lugs, cable glands and other accessories. The cable shall be laid underground and jointing of cable to be done if falls short to the LT panel complete all as specified and directed by Engr-in-charge. Note: (i)Cost of aluminium lugs, cable glands and termination of cable into LT panel shall be included in the quoted rate. (ii) Excavation, returning , refilling , crushed sand, brick cover and jointing kit will be measured and paid seperately.

2

-

-

... More
Material and labour for relaying of existing LT cable of any size up to 50 Sqmm 3.5/4 core under the ground complete all as specified and directed. Note: Excavation, returning , refilling , crushed sand, brick cover will be measured and paid seperately.

50

-

-

... More
Material and labour for relaying of existing LT cable of any size above 50 Sqmm 3.5/4 core to 300 Sqmm 3.5 core under the ground complete all as specified and directed. Note: Excavation, returning , refilling , crushed sand, brick cover will be measured and paid seperately.

50

-

-

... More
Material and labour for servicing of LT panel duly isolated / de-energize the supply of LT panel of capacity ranging from 200 Amps to 1000 Amps and voltage 415/230 volts. The maintenence includes the following tasks:- (i) Cleaning of burnt Bus bar using CTC chemical. (ii) Taking out all incoming and ougoing cables from the LT panel and also taking out cable loop from ground. (iii) Removing old insulation and providing new heat shrink insulating sleeves, connecting and fixing in the same panel using new GI nut bolts washers of suitable size. (iv) Removing of old and broken cable connectors in the LT panel and providing new connectors of suitable capacity and fixing in the same panel using nut bolts and other accessories. (v) Removing of burnt and worn out lugs from the cables and replace it with new aluminium lugs of suitable size and capacity as per the size of the cable. (vi) Removing of worn out connecting wires inside the panel and replace it with new wires of suitbale capacity and size. Note:Cost of all material as mentioned above required for maintenance must be included in the quoted rate

4

-

-

... More
Material and labour for painting to existing steel tubular poles 7/9/11 mtr long including cross arms,looping box,GI pipe bracket,clamps etc. with one coat of aluminium paint including preparation of surfaces and feeder name and pole number with zebra type painting upto 6 feet from bottom with alternate patch of size 1 foot of white and light blue colour paint complete all as directed.

35

-

-

... More
Material & Labour for painting to feeder pillar box / LT panel & duct cover etc, including angle iron frame with two coat of grey synthetic enamel paint including welding of door with proper size new hinges of suitable size and locking arrangements where required complete as specified.

20

-

-

... More
Provn of services for cable fault location for LT UG cable, XLPE insulated 1100 Volts, of any size with fault detector machine complete all as specified and as directed.

4

-

-

... More
Material and labour for straight through jointing kits heat shrinkable type LT UG XLPE cable heavy duty armoured sheathed including excavation in any strata, taking out cable, and making disturbed surface after relaying the cable making joints suitable for aluminium conductor of size given below all as specified and directed.

-

-

-

... More
(ii) 6 to 16 sqmm 3.5 core

2

-

-

... More
(iii) 25 to 50 sqmm 3.5 core

3

-

-

... More
(iv) 70 to 120 sqmm 3.5 core

2

-

-

... More
(v) 150- 185 sqmm 3.5 core

2

-

-

... More
(vi) 240-300 sqmm 3.5 core

2

-

-

... More
Taking down and Supply and fix in repair / replacement of MCCB FP 400 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning complete all as specified and directed.

1

-

-

... More
Taking down and Supply and fix in repair / replacement of MCCB FP 250 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning complete all as specified and directed.

1

-

-

... More
Taking down and Supply and fix in repair / replacement of MCCB TP 200 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning complete all as specified and directed.

1

-

-

... More
Taking down and Supply and fix in repair / replacement of MCCB TP 160 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning complete all as specified and directed.

2

-

-

... More
Taking down and Supply and fix in repair / replacement of MCCB TP 100 Amps Fixed type with breaking capacity 16 KA including connections and testing for proper functioning complete all as specified and directed.

1

-

-

... More
Supplying, Laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified for following size:-

-

-

-

... More
(i) 240 sqmm 3.5 core

35

-

-

... More
(ii) 300 sqmm 3.5 core

35

-

-

... More
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole etc.

-

-

-

... More
Soft/loose soil

9.45

-

-

... More
Hard/dense soil

7.88

-

-

... More
Soft/disintegrated rock

1.58

-

-

... More
Returning/ Refilling of excavated soil including spreading levelling and well ramming in layers for any type of soil.

13.23

-

-

... More
Removing the surplus spoil to a distance not exceeding 50 mtrs from the starting point and depositing at a height not exceeding 1.5 m above ground level.

5.67

-

-

... More
Material and labour for stone dust sand cushioning to under ground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable all as specified and directed. [Note : Measuremenet will be done after punning]

5.67

-

-

... More
Taking down and Supply and fix in repair / replacement of APFC Controller for contactor switching with 1 CT input 6 Step including connections and testing for proper functioning complete all as specified and directed.

1

-

-

... More
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 25 X 4 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab cover 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade, including galvanised iron strip 25X4 mm with GI protection pipe of 40 mm medium grade up to 7.5 meter length, etc complete all as specified.

1

-

-

... More
M& L for testing of APFC panel for proper functioning in manual & auto mode, including re-wiring the burnt out wires, replacing the wiring ducts/casing capping, fuse units and cleaning and testing complete all as specified and directed by Engr-In-Charge.

1

-

-

... More
Preventive Maintenance and Servicing of Servo Voltage Stabilizer, Oil Cooled & Indoor type of Capacity 400 to 630 KVA, 415 Volts, 50 Hz, AC Supply by disconnecting carefully its electric cable connection on primary & secondary side, Checking both side bushing, bus bar connections, opening top cover of the Voltage Stabilizer by unscrewing its nuts, bolts, washers etc, rectify the oil leakages issues, if noticed any, during servicing and re-fixing the top cover of voltage stabilizer according to previous system. Servicing of the Servo Voltage Stabilizer must be done through OEM or authorised personnel including maintaining and submitting the inspection and testing records of each Servo Voltage Stabilizer to the Engr-in-Charge. Note 1. :- Inspection of Servo Voltage Stabilizer shall involve :- (a) Checking of all clamps, nuts, bolts including core bolts & cover fixing bolts etc. (b) Checking all brazings, joints, tap heads, gaskets and connection joints etc. (c) Checking all terminations / connections inside Voltage Stabilizer. (d) Checking moving and fixed contacts for contact wear and connection to winding etc. (e) Conducting the test on dimmer/windings as per relavent IS like, short circuit, IR Value and Voltage regulation test etc. in presence of Engr-in-Charge. Note 2. : The rates quoted against the item is deemed to be included for cost of Labour for lifting/transporting to civil workshop and vice-versa, if required as per site requirement without any extra cost to the department.

1

-

-

... More
S & F in replacement Sensing Control Card, 240 Volts, 50 Hz, AC, suitable /compatible to existing Servo Voltage Stabilizer, Oil Cooled type, of capacity 400 to 630 KVA complete all as specified and directed.

1

-

-

... More
Supply and top up of voltage stabilizer oil with di-electric strength not less than 50 KV in to the body tank of the voltage stabilizer at various locations complete all as directed by the Engineer-in-Charge and also submit the test result before and after the top up.

55

-

-

... More
S & F in replacement ampere meter including suitable size of CTs, ring type, 240 Volts, 50 Hz, AC, suitable /compatible to existing Servo Voltage Stabilizer, Oil Cooled type of capacity 400 to 630 KVA.complete all as specified and directed

1

-

-

... More
M & L for dehydration/filteration of voltage stabilizer oil at site by taking proper shutdown of various capacity of Voltages Stabilizers located at various Sub Stations inside Air Force Stn Pune, desired di-electric strength of oil not less then 50 KV complete all as directed and specified and also submit the test result before and after the de-hydration of the stabilizer oil complete all as specified and directed.

500

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.