Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date31 Jan 2025
Closing Soon18 Feb 2025
Tender Amount₹ 21,00,000
Costs
EMD
₹ 42,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_695909_1Tender No
8268/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Demolition of stone slab and tiles of any description or thickness in floors, wall all as directed.Complete all as specified and as directed by Engineer-In-Charge
1.2
-
-
... More
M&L for 20mm thick Granite (of any type) tiles machine cut, in skirting/ dado including 10 mm thick rendering of CM 1:4 and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and as directed by Engineer-In-Charge
12
-
-
... More
S&F 12mm thick toughned glass for door or vertical cladding or railing etc Make : Saint Gobain/ Modi/Swastik or any equvilant shall be provided with monogram/logo ( one logo of RCMA) by etching on glass, filling the etching with multiple colour & design or any approved by Engr-in-Charge. Film coating making holes to glass for fixing , fixed pivet in glass door, edge polishing to glass complete all as directed by Engr-in-Charge.
9.3
-
-
... More
Supply and fixing 18" long SS Handle Make : Shivalik for door all as specified and directed by Engineer in Charge
4
-
-
... More
S&F Double action floor spring hydraulically regulated made ISI marked make: Dorma up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed all as specified and directed by Engineer in Charge
2
-
-
... More
Supply and fixing SS lock for toughened glass door for single leaf shutter
2
-
-
... More
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc. 1.5 Sqm but n.exc. 4 Sqm each compete all as specified as directed by Engineer -in -charge .
1
-
-
... More
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding,buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement.
15
-
-
... More
Dismantling Aluminium partitions or office partitions of any description and refixing properly as directed complete all as specified.
20
-
-
... More
Repairs to aluminium door shutter of any description and size including taking down from frames for realignment and tightening including adjusting the shutter removal and refixing hydraulic or floor door spring , and hinge , refixing shutter in same opening with all necessary repairs /refixing ,including replacement of damaged jointing cleats ,glazing clips , rubber packing ,aluminium beading , screws etc also including provision of 6 mm dia through bolt with nut on both side for top and bottom rail. complete all as specified and as directed by Engineer-in-charge. ( work shall be carried out in MD Qtrs/ OTM accns in different locations of Domestic/ Technical area as per site requirements upto 4 storieyed building)
Hydraulic door closer/ door spring if preplaced under separete items
10
-
-
... More
Ditto as Item No.13 But Aluminium windows of any type/ mechanisum except of Hydraulic / floor door spring. Wire mesh/ glass shall be paid under separate item above the rates includes replacement of rollers/ sliding arrangement/locking arrengments/ any types of hinges .if during repalcement of wiremesh/ glass window requires dismanteling of complete window with frames and shutters the same shall be carried out and the rates are deemed to included such provisions under this item and nothing shall be paid extra.
5
-
-
... More
Material and labour for providing Aluminium shutter with powder coated frame 88.9mmx47.63mmx1.60 mm thick and size of shutter with top rail , middle rail and bottom rail and style of size 85 mm x 44.5 mm x 1.56 mm thick with 200 mm size powder coated 2 nos with each leaf , Heavy duty powder coated aluminium tower bolt 150mm long 2 Nos per leaf, 3 nos Heavy duty aluminium powder coated hinges of size 125mm with each leaf including 12 mm thick both side prelaminated particle board / 5.5 mm thick glass pane in the both panel with necessary joining cleats, rubber packing, aluminium beading, hydraulicc door closer ,screws etc complete all as specified and as directed Note - All fitting shall be of same finished as of door shutter and shutter may be single/ double leaf, if the shutteris more than 1.10mtr it shall be of double leaf, the hollow section of vertical style where the hinges are to be provided the complete vertical style shall be provided with soft wood and minimum 65mm long screw provided for fixing of hinges compete all as specified as directed.
3
-
-
... More
Taking down carefully existing bitumen tarfelt including plastering upto 15mm thick cleaning the surface and make free of dirt, foreign particles, laitance followed by grinding all protrusions to make surface modulated and removing all foreign materials / Bituminous primer completely , cleaning and washing the existing surface of roof/slab, terraces including flashings and junctions of parapets/kerb walls etc and as directed by Engineer-in-charge. Note : (i) Contractor will not throw the debris and suitable arrangements shall be made to take down the materials from roof.
(ii) If taking down of plaster is exceeding 15mm then PCC and plaster both shall be measured under item below
(iv) Removing of the rubbish to a distance outside MoD land shall be at own arrangement of Contractor.
500
-
-
... More
M&L for providing cement concrete 1:2:4 Type B0 (Using 12.5mm graded stone aggregate) as in bed plate/roof kerb/PCC padding and haunching etc all as specified and directed by Engr in Charge
Note : PCC shall be laid in slope and thickness shall be average(minimum average thickness 25mm or as per site requirement for maintaining the slope) as per site including filling in depression by providing concrete bench marks for maintaining th perfect slope to drain out the rain water as directed by Engr-in-Charge.
No hand mixing is allowed, mixing shall be at ground floor and mixed materials deposited on roof Manually/ mechanically to achieve the proper strength and workmanship.
0.5
-
-
... More
M&L for rendering 15 mm thick in CM 1:4 on concrete surfaces mixed with water proofing compound @ 0.12 ltr per bag of cement or as per manufacturer instruction and finishing the surfaces even and smooth without using extra cement. Note:- (Supply only water proofing compound shall be measured and paid separately).Complete all as specified and directed by Engineer-in-charge. Note : Plaster shall be laid in slope and thickness shall be average as per site including filling in depression by providing cement mortar bench marks for maintaining th perfect slope to drain out the rain water as directed by Engr-in-Charge.
No hand mixing is allowed, mixing shall be at ground floor and mixed materials deposited on roof Manually/ mechanically to achieve the proper strength and workmanship.
500
-
-
... More
M&L providing cement slurry @ 3Kg per sqm on existing roof surface before laying PCC/ Plaster.
500
-
-
... More
Supply only Liquid water proofing compound
12
-
-
... More
M&L for cleaning the newly plastered surfaces thoroughly with wire brushes and providing water proofing treatment all as given here in after
(a) Bituminous primer @ 0.3lit per Sqm conforming to IS-3384-1986 (b) 3 mm thick APP polymer modified moply FP of M/S TEXSA Ltd or M/S STP Ltd or ASIAN PAINTS of Hydrostop Tiki Dan of M/s Tikki tar Ltd with minimum wt 3.0 Kg per square metre membrane (one layer) laid by torch application method.
(c ) Applying two coat of bituminous based aluminium paint @ 0.20 Kg in two coats (total in two coats) per square metre over membrane. Complete all as specified and directed by Engineer-in-charge.
(d) The overlaps of APP shall beas per SSR part 1 and APP shall be laid by expert/ skilled workers only, bitumen based aluminous paint applied by brushes only.
500
-
-
... More
S&F in repairs gun metal, globe or gate valve, bore dia of pipe in 15 mm,
1
-
-
... More
S&F in repairs gun metal, globe or gate valve, bore dia of pipe in 20 mm,
1
-
-
... More
Taking down steel tubing of 15 mm dia bore and connections from walls and ceilings or laid in floor including cleaning for refixing in same position (walls , ceiling, floors etc).
3
-
-
... More
All as item No. 24 but 20 mm bore.
2
-
-
... More
Supply and fixing tubes medium grade galvanized with all fittings and fixed complete to walls and ceiling or laid in floor (Bore of pipe 15mm) complete all as specified complete all as specified and as directed by Engineer-In-Charge
3
-
-
... More
Supply and fixing tubes medium grade galvanized with all fittings and fixed complete to walls and ceiling or laid in floor (Bore of pipe 20 mm) complete all as specified complete all as specified and as directed by Engineer-In-Charge
2
-
-
... More
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles
4
-
-
... More
Complete removal of old painted surfaces by machinal removal and preparation of surfaces by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and greasy spots , removing nails etc., bringing surface to level by applying external wall care putty and applying two coats of exterior Acrylic emulsion (Apex)/Equivalent any colour on walls with and including provision of scaffolding required for the treatment to external surfaces of building with required safety measuers etc complete all as specified and as directed by Engineer in charge
1500
-
-
... More
Complete Removal of existing treatment and applying two coat of Oil bound distemper over a coat of primer after smoothing of surfaces complete of wall and ceiling all as specified and as directed by Engineer in charge
1000
-
-
... More
M&L for 2 coat of 1.5 mm thick Birla Wall care putty on walls surfaces complete all as specified and as directed.by Engr in charge.
1000
-
-
... More
M/L for repairing of existing modular kitchen (n exc 2.5 sqm area) including taking down & refixing at the same location cabinet, shutters & SS Rack and repairing with required material etc.complete.(i.e. ss lock,hinge, knobs,screw,washers,telescopic channels etc.)
5
-
-
... More
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including gall quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles
2.76
-
-
... More
M&L Brick work with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1 : 6 all as specified and directed by Engr-in-Charge
2.5
-
-
... More
Labour only for brickwork (except bricks) straight or curved on plan exc 6m mean radius, built in CM 1 : 6 all as specified and directed by Engr-in-Charge
0.16
-
-
... More
M&L for 10 mm thick cement plaster in CM 1:6 on brick surface finished even and smooth without using extra cement in patches Complete all as specified and directed by Engineer-in-charge.
50
-
-
... More
M&L for Preparation of new surfaces by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and greasy spots, removing nails etc., and applying two coat of distemper oil emulsion over a coat of primer white or tinted on walls including cornices etc.complete all as as specified and as directed by Engineer in charge
50
-
-
... More
S&F Mineral Fibre acoustical suspended ceiling system with Bevelled/Tegular EDGE TILES with 15mm exposed or inward grid(projected ceiling tile) as approved. The tile should have humidity resistance (RH) of 95%, NRC 0.5 , Light Reflectance 85%, Thermal Conductivity k= 0.052-0.057 w/m k. Colour white Fire Performance UK Class 0 /Class 1 (BS 476 pt- 6&7) in module size of 600 x 600 x 20 mm suitable for Green Building application, with Recycled content of 54%. The tile shall be laid on GI grid with 15 mm wide T - section flanges colour white having rotary sittching on all T sections i.e. the main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 14 Kgs/M2 & minimum pull out strenght of 100 Kgs. The T section have a Galvanizing of 90 grams per sqm and need to be installed with Suspension system as required on site of any shape and size. Make: USG/Knauf/ Armstrong, Anchor or equivalent.
20
-
-
... More
Dismantling wall/ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets
20
-
-
... More
Labour only for opening of air locks in toilets /baths and kitchen water pipe line but excluding fittings complete all as specified.complete all as specified and as directed by Engineer-In-Charge
10
-
-
... More
Labour only to adjust the float valves of 15/20/25mm dia of tanks of any capacity up to 8000 ltr capacity and upto 4 storey bldg.
10
-
-
... More
Servicing of Flushing system 10 litres capacity PVC Valveless symphonic action type flushing cistern low level . Taking down the all materials from existing cistern, Cleaned all dirt and refixing the same with making good and leakage free condition for 1 year, including repalcement of folat valve, Syphone, flush washer and flush handle with all fixing arrengments complete all as direceted.
16
-
-
... More
Taking down and refixing the 15mm dia CP Bib Cock/ Piller cock/ Angle cock/Concealed stop cock of any make with replacement of washer complete. The Bib cock/ Piller Cock/ Angle cock shall be fixed with Taplane tape without damageing the exising pipe lines complete. The rate includes dismanteling of tiles and making good if required
15
-
-
... More
S&F in repair brass spindle for CP Bib Cock/ Piller cock/ Angle cock/Concealed stop cock of various make 15mm dia.
10
-
-
... More
Supply only CP Head for CP Bib Cock/ Piller cock/ Angle cock/Concealed stop cock of various make under 15mm dia.
10
-
-
... More
Fixing in repair wash basin mixer/ Wall mixer cast copper alloy, chromium plated central hole without popup waste system with 450mm long copper pipe and brass nut complete all as direceted.
4
-
-
... More
Supply and fixing in repairs Aluminium wire cloth power woven 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanized wire staples for Aluminium window and ventilator . Complete all as specified and directed by Engineer-in-charge.
10
-
-
... More
S & F in repairs curtain rod of CP MS 25 mm dia not less than 1.6mm thickness with chromium plated projected bracket both side as per sample fixed in position by drilling holes in walls and fixed the brackers with rawl plug and steel screw compete all as specified as directed by Engineer -in -charge
50
-
-
... More
S/F SS fancy type end balls fixed to SS rod as approved by Engr in charge
40
-
-
... More
S&F in Repair CP waste coupling 32 mm dia for wash basin
3
-
-
... More
Ditto as in item No 50 above but 40 mm dia for Sink for ISI Marked
2
-
-
... More
S & F in Repair 32 mm PVC flexible pipe for waste outlet with threaded socket at one end.complete all as specified and as directed by Engineer-In-Charge
10
-
-
... More
S & F in Repairs 40 mm PVC flexible pipe for waste outlet with threaded socket at one end.complete all as specified and as directed by Engineer-In-Charge
10
-
-
... More
Dismantling Asbestos cement /FRP sheet/GI sheet(corrugated ted, semi corrugated, etc.) sheets in roof coverings up to height 25M and taking care of earthing strip and refixing all as specified and directed by Engr in Charge
86
-
-
... More
S&F for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
50
-
-
... More
M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel for matching profile at corners sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
6
-
-
... More
Cutting holes in brick walls in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required
108
-
-
... More
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,
0.75
-
-
... More
M&L for cement concreting type B2 1:2:4 (40mm graded stone aggregate) in walls or retaining walls, any thickness, size
or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases)
0.75
-
-
... More
Dismantling wrought iron or mild steel work of any description not otherwise provided for
20
-
-
... More
S&F for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded
tubes conforming to I. S.1161- 1979 grade St.-240
2000
-
-
... More
Preparation of new painted surfaces of steel and iron of any description, over 10 cm in width or girth, not otherwise described include for all necessary preparatory work required and applying two coat of synthetic enamel paint over a coat of zinc chromate primer complete all as specified and directed by Engineer in charge.
70
-
-
... More
Taking down cement plaster on brick or stone wall any description including raking out joints, hacking for key, scrubbing down with water etc.compete all as specified as directed by Engineer -in -charge.
70
-
-
... More
M&L for 15mm thick rendering on brick/concrete surfaces on broken edges of chajjas, facia, slab, roof projectioon and any other brick/concrete surface in patch work in CM 1:4 and finishing fair and even without using extra cement with using 2% Integral water proofing compound by wt of cement (Note: Water proofing compound will be measured and paid separately under relevant item) Note: The rate quoted shall be deemed to include for work up to four storey building & height upto 15.00m including all safety measures, scaffoldings etc., required for carrying out the work and nothing extra on this account shall be admissible.
70
-
-
... More
M&L for applying 2 component polyurethane polymer based water proof coating of TECHCOAT of make Choksey or equivalent as per manufactures intsruction over roofs, chajjas after plaster repair of Make: Asian Paints/ Berger all as approved and specified.
70
-
-
... More
Supply only Liquid water proofing compound
10
-
-
... More
S&F 5.5mm tinted glass in repairs for aluminium doors or windows with glazing clips and other necessary accessories
1
-
-
... More
M&L for cleaning old surfaces by dusting, washing and applying two coat of plastic emulsion paint of berger or asian make of first quality on old surfaces etc completed and as directed by Engr in charge
25
-
-
... More
M&L for preparation of new surfaces by dusting, washing and applying two coat of plastic emulsion paint of berger or asian make of first quality over primer as per manufacturer instruction etc completed and as directed by Engr in charge
25
-
-
... More
Preparation of old painted surfaces of steel and iron of any description, over 10 cm in width or girth, not otherwise described include for all necessary preparatory work required and applying one coat of aluminium paint complete all as specified and directed by Engineer in charge.
50
-
-
... More
M & L for 75mm thick Cement Concrete type B0 (1:4:8) using 40 mm graded stone aggregate as in sub base of floor
50
-
-
... More
M & L for 50 mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) inc Spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green
50
-
-
... More
M & L for 6mm HPL sheet in approved shades/wooden series cut to required shape as cladding to pillar complete all as specified and as directed by Engineer-in-charge Make:- Pioneer or equilent
15
-
-
... More
S&F of sandwich insulated PUF roof panel manufacture in continuous production line using of Pre- painted galvalume aluminum zinc coating GI based corrugated sheet(TATA/Jindal or equivalent) 0.40mm thick sheet at top and bottom yeild strength should be 550Mpa as per ASTM A-792 colour coating RMP (25 micron) RAL-9002 Panel thickness should be 40kg/cum(+/- 2kg/M3) HSN Code 73082019. Roof panel effective width should be 1000mm top and bottom PPGL sheet should be protected with plastic film guard from scratch protection roof top should be 333mm with 3 stiffing ribs at 1000mm crest height from bottom sheet should be 90mm side lapping and over lapping joint will be vapour tight with guard film protection on all exposed surface and shall confirm to IS 12346. Note: Work will be carried out through authorized vendor.
15
-
-
... More
Excavating over areas, n exc 1.5 m deep and getting out in soft loose soil
7.2
-
-
... More
Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
7.2
-
-
... More
Removing of building materials & debries of any type the rate included i.e loading ,unloading and stacking/spreading etc outside of MD land upto 1 km with own arrangement by Contractor(1 load -6Cum).
5
-
-
... More
Taking down existing copper/aluminum existing point wiring (light/fan/socket or power points) complete (fittings such as switches,ceiling roses,pendents, regulators, sockets etc to be measured saperatly) incl wooden battens and conduct etc & removing material as directed complete all as specified and as directed by Engr-in-Charge.
90
-
-
... More
M&L for Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run in and including surface in wall/celling/floor PVC casing caping as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including PVC boxes with surface plate suitable for housing switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr-in-Charge.
25
-
-
... More
All as per item no 79 but for One 5 Amps socket point on same/below board with other switches.
10
-
-
... More
All as per item no 79 but for One 5amps switch socket point independent.
10
-
-
... More
M&L for Point wiring with 2.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run including surface in wall/celling/floor in PVC casing caping as per IS with all fittings such as bends, tee, junction boxes,etc of suitable size including 2.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with surface plate suitable for housing switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge. Note - Cutting and making good of chasis in wall/roof/floor is included in the qtd rates.
10
-
-
... More
Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run in and including concealed in wall/floor PVC conduit not less than 20 mm as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge.
20
-
-
... More
All as per item no 83 but for One 5 Amps socket point on same/below board with other switches.
5
-
-
... More
All as per item no 83 but for One 5amps switch socket point independent.
5
-
-
... More
M&L for Point wiring with 2.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run consealed in wall/floor PVC medium grade conduit not less than 20 mm as per IS with all fittings such as bends, tee, junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge. Note - Cutting and making good of chasis in wall/roof/floor is included in the qtd rates.
5
-
-
... More
M&L wiring for circuit/ sub main wiring of 2x1.5 Sqmm + 1x1.5 Sqmm earth wire, alongwith earth wire PVC (FRLS) insulated copper conductor, single core, 1100 v grade cablein PVC conduit / cassing capping complete all as directed by Engr -in- Charge.
50
-
-
... More
M&L wiring for circuit/ sub main wiring of 2x2.5 Sqmm + 1x2.5 Sqmm earth wire, alongwith earth wire PVC (FRLS) insulated copper conductor, single core, 1100 v grade cable in surface/concealed as required in PVC conduit / cassing capping complete all as directed by Engr -in- Charge.
50
-
-
... More
M&L wiring for circuit/ sub main wiring of 2x4 Sqmm + 1x4 Sqmm earth wire, alongwith eart wire PVC (FRLS) insulated copper conductor, single core, 1100 v grade cable in surface/ recessed as required in PVC conduit/ casing caping complete all as directed by Engr -in- Charge.
50
-
-
... More
M&L wiring for circuit/ sub main wiring of 2x6 Sqmm + 1x6 Sqmm earth wire, alongwith eart wire PVC (FRLS) insulated copper conductor, single core, 1100 v grade cable in surface/ recessed as required in PVC casing caping complete all as directed by Engr -in- Charge.
20
-
-
... More
Supply and fix in repair Switch socket combination outlet 5 pin 6 Amps 16 Amps 2 in 1 flush typein PVC box.Make: Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
25
-
-
... More
Supply and fix in repair Switch socket combination outlet 5 pin 5 Amps 2 in 1 flush type in PVC Box Make : Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
25
-
-
... More
Supply and fix in repair Ceiling rose surface type, PVC/Polycarbonate isolated body size 50x28 mm three terminals. Make : AnchorHavells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
105
-
-
... More
Supply and fix in repair PVC rectangular board 100 mm x 100 mmx 50 mm deep. Make : Press Fit or equavelent ,Complete all as specified & as directed by Engineer-In-Charge.
10
-
-
... More
Supply and fix in repair PVC rectangular board 175mm x 100mmx50mm deep. Make : Press Fit or equavelent.,Complete all as specified & as directed by Engineer-In-Charge.
10
-
-
... More
Supply and fix in repair PVC rectangular board 200mmx150mmx50mm deep. Make : Press Fit or equavelent.,Complete all as specified & as directed by Engineer-In-Charge.
5
-
-
... More
S&F in repair thermostat having range 0 to 100 C for geyser as original size of 25/35/50ltrs capacity geyser sutiable for Ditzs/ Racold/ Shakti/Spheroat Make.
3
-
-
... More
S&F in repair heating element 2 KW with round or triangular base for 50 ltrs capacity geyser sutiable for Ditzs/ Racold/ Shakti/Spheroat Make.
3
-
-
... More
General servicing/maintenance , repair Split AC capacity 1.5/2 Ton ,dismantling unserviceable part of unit including cleaning of air filter,display,PCB,de-dusting of complete(indoor/outdoor) unit ,washing condensor unit with suitable water sprey jet, checking electrical connection cleaning the unit with blower, descaling with non-corrsive acid on both side of coling oil identifying the fault / trouble in unit & their redressal /rewiring complete, greasing of movable parts for getting trouble free service & making Split AC serviceable complete all as specified and directed by Engineer-In-Charge. (Note: Repair/Replacement of the component required shall be paid under relevant item of scedule here-in-after. 2-the rate for gas charging including refregerent gas will be included in quoted rates for serviceing )
10
-
-
... More
Supply and fix in repair new sealed unit compressor 1.5 Ton split air conditioner Make: Kirloskar complete all as specified & as directed by Engineer-In -Charge.(Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
1
-
-
... More
Supply and fix in repair new sealed unit compressor 2.0 T for split air conditioner Make:Kirloskar complete all as specified & as directed by Engineer-In -Charge. (Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
1
-
-
... More
Supply and fix in repair new fan motor 1/3 Hp ,230 v for split AC Make AUE or equivalent all as specified and as directed by Engineer -in Charge.
1
-
-
... More
Supply and fix in repair running capacitor for split Air conditioner 1.5 T/2 T of capacity 36/45 mfd , 7 point ,440 VAC Make Epcos ,complete all as specified and as directed by Engineer -in -Charge
1
-
-
... More
Supply and fix in repair starting capacitor for split Air conditioner 1.5 T/2 T of capacity 80/100 mfd 440 VAC Make Epcos, complete all as specified and as directed by Engineer -in -Charge
1
-
-
... More
Supply and fix in repair Relay (8500-4) (Make Annapurna) suitable for Air Conditioner mentioned above, complete all as specified & as directed by Engineer-In -Charge.
1
-
-
... More
Supply and fix in repair remote control switches 1.5 Ton to 2 Ton capacity split A/C of any make as existing sample complete all as specified & as directed by Engineer-In -Charge.
1
-
-
... More
Supply and fix in repair blower motor single phase AC 200/230 volts suitable for split model A/C of capacity 1.5 TR, complete all as specified & as directed by Engineer-In -Charge.
1
-
-
... More
All as per item no 107 here-in before but for 2 TR complete all as specified & as directed by Engineer-In -Charge.
1
-
-
... More
Supply and fix in repair Bush with Blower shaft assy complete,1.5 Ton to 3 Ton capacity split A/C of make as existing sample ,complete all as specified & as directed by Engineer-In -Charge.
1
-
-
... More
Supply and fix in repair Printed Circuit Board (PCB) For split A/C of make as existing sample ,complete all as specified & as directed by Engineer-In -Charge.
1
-
-
... More
Repairs to Circuit of existing Printed Circuit Board (PCB) in split type AC of any make, complete all as specified & as directed by Engineer-In -Charge.
1
-
-
... More
Supply and fix in repair condensor coil of copper suitable for 1.5 TR/2 TR split type air conditioner including taking down old unserviceable condensor coil from existing position complete all as directed and specified by Engineer-In Charge
1
-
-
... More
Supply and fix in repair copper tubes 2 mm thick for additional length required in the process of maitenance of the split air conditioners unit, with insulation of puff or TF quality of thermocole or poly urithine insulating tubes all as specified for 5/8/1/4 inch copper tubing complete all as specified & as directed by Engineer-In -Charge.
Note- applicable for BOQ item no 1 to 36 (a) contractor rep/ superviser shall be present at office of Engineer-In-Charge at 9AM every day for taking of instruction regarding repairs to be carried out on the day on priority to attend faults/defects/complains or refixing of old or new fitting / fixtures as provided by E/M Sub div for free fixing at site. In case if electrician fails to rectify the faults then recovery shall be recovered from contractor s any due payment(c)The repair work on any single day may be order by Engineer-In Charge to be carry out in number of places/building in one day i.e in one buildings quantity of any of BOQ items to be carried may be one or more & number of BOQ items to be executed on any single day may also be one or more(d) Contractor shall not have any claim on account of order of one or more quantity of one or more items of BOQ that to be executed in one or more building and or area in any single day & even the same on any numbers of day during contract period(f) all above mentioned labour effect on this account is deemed to be included in quoted rates by the tenderer for all items of this tender.Note:1) Complaints/Defects will be rectified withen 8 Hrs of intimated time. if complaints not rectified, a recovery of an amount of Rs150/-/ complains/ day will be recoverd from the RAR/ FB , ii) Rates are inclusive of T&P required safety equipment, and transport required contractor shall arrange on his own arrangement, iii).Compliant given by any electronic media i.e SMS, email or whats app etc and in writting shall be count as valid compliant contractor to take immediate action within stipulated time as mention in note -1 above.
5
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user