Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Eprocure
Opening Date18 Feb 2020
Closing Date18 Mar 2020
Tender Amount₹ 28,47,102 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 58,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_MES_326179_1Bid Award Id
ViewTender No
83549/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
TENDER INVITING FOR SPECIAL REPAIRS TO BUILDING NO P-69 WING-V OF SPORTS BTY AT ARTY CENTRE UNDER GE NASIK ROAD CAMP
BOQ Items
... More
Dismantling wrought iron or mild steel work of any description not otherwise provided for including gas cutting, welding etc.
2
-
-
... More
S&F rolled mild steel Joist, channel, angle, flat sections, fixed independently, without connecting plates, MS tubular sections etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) grade Fe 290( E-165) all as directed by Engr-in-charge
200
-
-
... More
M&L two coat of synthetic enamel paint over one coat of red oxide primer on new steel surfaces, girth or width exc 10cm
50
-
-
... More
Dismantling of stone slabs & tiles of any description or thickness (except ceramic tiles) in floors, aprons etc laid bedded & pointed in any mortar complete all as specified and directed
2
-
-
... More
S & F machine cut cudappa stone slab 16-18 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete Note: screed bed layer measured seperately complete all as specifed and directed
10
-
-
... More
M&L granite (of any type)work (table rubbed and polished) 18 mm thick in steps,jambs,pillars,cooking platforms and like in cement mortar 1:4 incl pointing in white cement 1:2 using marble dust with admixture of pigment to match the shade of granite
10
-
-
... More
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations
50
-
-
... More
Demolition of brick work or stone boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillers etc but including ashlar facings, dressed stone work and precast concrete articles
6
-
-
... More
Brick work with fly ash bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 with old size bricks.
3
-
-
... More
Brick work with fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 with old size bricks.
13
-
-
... More
Taking down cement plaster on brick or stone wall etc including raking out joints hacking for keys scrubbing down with water etc. including removing all the debris out side MD land
75
-
-
... More
M&L for rendering 5 mm thick (1: 3) on fair faces of concrete surfaces incl preparation to new surfaces on ceilings finished even and smooth without using extra cement
25
-
-
... More
M&L for rendering 15 mm thick cement plaster on than fair faces of brick work or concrete surfaces in CM 1:4 rendering is to be finished even and smooth without using extra cement.
30
-
-
... More
M&L for rendering 10 mm thick (1: 6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement
20
-
-
... More
M&L Preparation of new plastered surfaces and applying two coats of white wash on ceiling surfaces all as directed
25
-
-
... More
M&L for preparing new plastered surfaces and applying Two coats of cement base paint over a coat of primer on surfaces of walls.
30
-
-
... More
M&L for preparing New plastered surfaces and applying two coats of distemper oil emulsion over a coat of white wash on surfaces of walls.
20
-
-
... More
S&F in repair stainless steel sink made of stainless steel 1mm thick with out drainage board including plugs, washers and wastes including bedding in cement mortar to dwarf wall or including fixing contilever brackets and connecting union to pipe overall size 495mm x 420mm, bowl size 410mmx330mmx160mm complete all as specifed and directed
12
-
-
... More
Dismantling wall and ceiling boards( Fibre, pulp, insulation etc) or insulation boards any thickness including cover fillets complete all as specified & directed.
716
-
-
... More
S&F interlocking aluminium powder coated snap grid consists of main Tee runners of size 38mm x 25mm x 1.00 mm spaced 1200mm centre to centre and cross Tee of size 25mm x 25mm x1.00mm, 1200 long spaced between the main Tee at 600mm centre to centre to form a grid of 1200mm x 600mm and provide a secondary cross Te 25mm x 25mm x 1.4mm (of length 600mm) to be interlocked of the centre of 1200mm x 600mm panel to form a grid of 600mm x 600mm and wall angle 25mm x 25mm x 1.5mm . Aluminium alloy extruded section shall be aluminium anodized ( minimum 15 micron) and shall conform to IS 733, IS 1285 and IS 737, and providing and fixing with Hangers of 4mm dia GI (upto 1200mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long size of grid 600 x 600mm complete all as specified and S&F non asbestos cement building board 4mm thick of make E board classic of M/s Everest industries Ltd or equivalent make as approved, “in ceiling fixed with screw as per manufacturer instruction”
716
-
-
... More
S & F in repairs looking mirror of selected quality glass, mounted on 8mm thick AC building board or commercial plywood including aluminium beading ( heavy section) all around and size of mirror with chromium plated brass screws and cup washers as specified and directed by Engineer-in-Charge
8
-
-
... More
M & L for special treatment to sunken portion with 10mm thick plaster in CM 1:4 with WPC @ 3% of cement mass by using Ditachment DM 1% by weight of cement and surface made smooth after curing period two coat of Ditachment DS shall be applied @ 2.50Kg/Sm. The paste like consistancy like is made by using 2.5Kg of Ditachment DS powder in one lit of admixture (The admixture volume of water) After 7 days curing, testing shall be done by flooring for 72 hours. Finally protective plaster coat of 10mm thick in CM 1:4 shall Detachment DS. All joints of CI pipe, Nahani trap, WC connection etc. shall be filled by mixture of cement, fine sand and 10% Nafufill SBR by weight of cement 32mm dia 450mm long GI spout light grade shall be provided in all sunken slabs to drain off water.
15
-
-
... More
S&F Vitreous china squatting pan ,'Orissa' pattern, size 580x440 mm white,with integral foot rests (excluding flushing cistern and flush pipe)
15
-
-
... More
S&F of PVC(SWR) 'P' trap of 125/110 mm bore
15
-
-
... More
S&F in repair vitreous china bowl urinal flat back size 465x355x265mm white with grating spreader and union and discharge pipe complete all as specifed and directed
4
-
-
... More
S&F for waste fittings,brass,chromium plated 40 mm dia for urinals
4
-
-
... More
Dismantling floor hearth or wall tiling including cement mortar bedding (But not backing) removing serviceable tiles to store and rubbish off the premises.
350
-
-
... More
M&L for 10 mm thick rendering in CM 1:3 on brick masonary or concrete rough finished surfaces as backing coat
200
-
-
... More
M&L for coloured glazed ceramic tiles 300 x 200 x 7mm / 300 x 450 x 7-8mm thick in vertical surface, set and jointed in neat cement slurry & pointed with white or coloured cement to match
200
-
-
... More
M & L for 15mm thick Screed bed or bedding layer in cement mortar 1:6 for laying floors finishes
150
-
-
... More
M&L non-skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tile all as specified and directed by Engr-in-charge
150
-
-
... More
S&F in repairs bib taps standared of PTMT 15mm bore dia any colour high presure screwed for iron pipe of Make Prayag fixed and repairs (minimum weight 90 gms) complete all as specified and directed
32
-
-
... More
S & F PVC connections 15mm size with PTMT nuts of length 300mm.
8
-
-
... More
S&F in repair stop valve, 15mm bore dia PTMT of any colour high pressure screwed for iron pipe and fixed (Minimum weight 90 gms) complete all as specified and directed
8
-
-
... More
Taking up or down tubes galvanized iron and connections and fittings or removal from site as incl cleaning for refixing where directed complete all as specified and directed.
-
-
-
... More
15 mm dia
40
-
-
... More
20 mm dia
30
-
-
... More
25 mm dia
10
-
-
... More
Re-fixing only tubes galvanized iron and connections fixed to walls or laid in floor supplying & fixing new fittings such as socket, bends, elbows nipple, union etc all as specified and directed of size complete all as specified and directed
-
-
-
... More
15 mm dia
20
-
-
... More
20 mm dia
20
-
-
... More
25 mm dia
5
-
-
... More
S&F for tubes medium grade, galvanized with iron all fittings fixed to walls, ceiling and laid in floor of sizes complete all as specified and directed :-
-
-
-
... More
15 mm dia
20
-
-
... More
20 mm dia
10
-
-
... More
25 mm dia
5
-
-
... More
S&F of PVC(SWR) pipes single socketed,in any length with rubber ring joints fixed to walls
-
-
-
... More
75 mm dia
9
-
-
... More
110 mm dia
24
-
-
... More
S&F of PVC(SWR) bends of any radius
-
-
-
... More
75 mm dia
4
-
-
... More
110 mm dia
16
-
-
... More
S&F of PVC(SWR) branch piece,single(single Y) equal or unequal
-
-
-
... More
75 mm dia
4
-
-
... More
110 mm dia
8
-
-
... More
S&F of PVC(SWR) junction single,(single T),equal or unequal
-
-
-
... More
75 mm dia
3
-
-
... More
110 mm dia
4
-
-
... More
S&F of PVC(SWR) Vent cowl
-
-
-
... More
(a) 110 mm dia
10
-
-
... More
(a) 75 mm dia
4
-
-
... More
S&F 50mm dia low density polyethylene pipes(LDPE) of pressure rating 6 Kgf/cm2 fixed complete to walls as directed by Engr-In-Charge
12
-
-
... More
S&F PVC(SWR) floor trap,plain with grating including jointing with solvent cement
8
-
-
... More
Taking down chowkat or frames with shutters (without taking off shutters from the frame not exc. 1.5 Sqm each.
5
-
-
... More
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain coloured PVC sheet reinforced with MS square tube S&F in opening as per specification and drawing
22.75
-
-
... More
S&F factory made soild panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & plain colour PVC sheets for top rail,lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification and drawing.
7.13
-
-
... More
S&F MS butt hinges 100mm size medium weight complete all as specified and directed
15
-
-
... More
S&F aluminium alloy barrel tower bolt 150 mm long
10
-
-
... More
S&F 150 mm aluminium alloy handels cast/plate type
10
-
-
... More
Taking down carefully existing bitumen tarfelt incl. Screed and cleaning of surfaces of roof etc. With wire brush incl. Flashing and junctions of parapets/kerb walls etc. And removing of the rubbish to a distance exc. 500 metres but not exc. 1.5 km and deposting where directed.
114
-
-
... More
M&L Rendering 15mm thick in cement mortar (1:4) or fair faces of concrete surfaces smooth finished (without using extra cement).
114
-
-
... More
Disconnecting existing tanks, exc 500 & n exc 1000 setting aside (or lowering if required), cleaning and removing all scale and dirt, etc. from tanks and from mouths of circulating pipes, etc. and hoisting if required reconnecting and re-fixing in position.
3
-
-
... More
Dismantling water tanks exc 250 & n exc 500 ltr capacity.
1
-
-
... More
S&F Rotational moulded poly-ethylene water storage tanks of1000 Ltrs capacity(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part-I
1
-
-
... More
S&F Ball brass valves, high pressure, with polythene float and flynut for 20 mm bore dia pipe complete,screwed for iron pipe or brass ferrule and fixed
1
-
-
... More
S&F for Gun metal,globe or gate valves,with iron wheel head,screwed both ends for iron pipe and fixed
1
-
-
... More
Demolition of concrete (unreinforced) of any description and in any position not otherwise specifically provided for.
0.5
-
-
... More
Providing, cement concrete type B1 1:2:4 (20 mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges.
0.5
-
-
... More
Waterproofing on roof including flashing and junction of parapet, kerb, wall etc. As under
(a) Applying bituminous primer on cleaned and dried surface @ 0.2 kg/sqm.
(b) Laying by thermo fusion ( torch applied) 3 mm thick APP based polymeric water proofing membrane weighing not less than 3.5kg/sqm and reinforcement with polyester non woven fabric ( not less than 150 gms/sqm)
(c) Painting the exposed APP membrane surface with bituminous paint @ 0.15kg/sqm
114
-
-
... More
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc ( Note -(1) credit for above items should be made as per conditions separately. (2) old servicable switch/socket/regulater/switch-socket shall be taken on charge for reuse)
248
-
-
... More
Taking down unserviceable/partly servicable light fittings any type, tube light fitting and fixtures, etc, and making good to the disturbed surfaces of walls/floor etc to macth with existing surfaces including white washing/colour washing/distempering to match with existing wall/floor/ceiling finishes.(.NOTE- old servicable fitting shall be reused against apropriate item)
128
-
-
... More
Dismantling unserviceable main switch/DBs with MCB incl wooden board and deposit to MES store yard including making good disturbed surface of wall
84
-
-
... More
Taking down sub main wiring of any size/capacity complete all as specified and making good disturbed sufaces to match with the existing surfaces.
274
-
-
... More
Point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC medium grade surface casing capping not less then 32 mm width with MS sheet metal sunken switch/Terminal box 1.2 mm thick and ebonite switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface all as directed and specified MAKE OF CABLE - Standard / PLAZA / HAVELLS/ Polycab & MAKE OF PVC CASING/CAPING - PRICISION/PRESSFIT/MODI .Note : Cutting chases and making good to match with the adjoining surface shall be included in the unit rate.
-
-
-
... More
(a) One light point controlled by one, one way switch
138
-
-
... More
(b) One ceiling /exhaust fan point controlled by one switch and regulator
40
-
-
... More
(c) One 3 pin 5 amp socket out point on the same board with other switches.
35
-
-
... More
(d) One3 pin 5 amps socket out let point on independent board
35
-
-
... More
(e) One light point controlled by two 2-way switches, with cables 1.5 sq. mm size
2
-
-
... More
S &F Switch piano flush type single pole one way 5 amps.
221
-
-
... More
S &F Switch piano flush type single pole two way 5 amps.
4
-
-
... More
S &F Socket out let 2 in one, 5/3 pin 5Amp
35
-
-
... More
S &F Switch socket combination 5 Amps 5 pin flush type
35
-
-
... More
S &F Ceiling rose, surface bakelite 65x50 mm three terminal
168
-
-
... More
S &F Electronic regulator 100/120 Watt step type
40
-
-
... More
S &F Lamp holder insulated body with back plate for angle holder all as per specified
10
-
-
... More
S & F 1x 18 watt universal batten for T5 and T8 lamps as regal batten for LED tube. Make Havells Cat No: REGALBATTENT8UPTO1X22WDSBSWH other then Eqvt Bajaj/CG
120
-
-
... More
S & F Ultra bright glass 18W LED tubelight with very high efficacy suited for installation in existing T8 fitting with G13 lamp holders as crystal glass LED Tubelight (Double Side Connection). Make Havells Cat No: CRYSTAL 1213T8DSTL18WLED865SGLASS other then Eqvt Bajaj CG
120
-
-
... More
S & F energy saving and environmental friendly long life 1X15 Watt LED street/security light made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection and Impact resistance of IK07, complete all as specified make- Havells Cat No-ENDURAPEARLSL15WLED757SASYTOPC or eqvt in Bajaj/C&S
8
-
-
... More
Fabrication,supply & fixing of GI pipe bracket up to 40 mm dia- 0.9m long & 2 set of clamps made out of 30x5mm ms flat & fixed with anchor bolt suitable for 1x15 w LED security light fitting
8
-
-
... More
S & F MCCB DB Vertical type made of sheet steel enclosure 4 way 415 volts TPN double door with detachable gland plates for flush / surface mounting with busbar, neutral link with earth bar complete all as specified and directed. (Make : Legrand, Cat part No. 507725 or equivalant of Havells /Standard / L&T)
2
-
-
... More
MCB DB made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, earth bar and Din rail , 240Volts SPN with 8 way Double door , IP-43-IK09 protection grade Make-,L&T / LEGRAND / equivalent of ABB
8
-
-
... More
MCB DB made of sheet steel, powder painted with bus bar 200 A, neutral link, earth bar and Din rail , 240 Volts SPN with 4 way Double door IP-43-IK09 protection grade, Make -L&T/ LEGRAND / equivalent of ABB
4
-
-
... More
NOTE FOR ITEM NO 80 & 82 -(1).The unit rate includes for cutting the brick walls to accommodate DB to make flush to wall.// DB tobe fixed on wall including frame made out of MS flat 40x5mm (2).The unit rate includes for making good the disturbed surfaces including finishes to match with the adjoining surface (3) MAKE OF DB & MCB - LEGRAND/ABB/L&T/HAVELLS (4) (note - rate is inclusive of cutting chases & flush to wall & making good to the disturbed surfaces of walls etc to macth with existing surfaces including white washing/colour washing/distempering to match with existing wall/floor/ceiling finishes making good disturbed surfaces of walls, etc )
-
-
-
... More
S & F MCCB TPN 63 Amps , 415Volts, 25KA ,4 pole, (Make - legrand , Cat part no. 4200 53, or equivalent of ABB, Standard
1
-
-
... More
S & F MCCB TPN 100Amps , 415Volts, 25KA ,4 pole, (Make - LEGRAND, Cat part no. 4200 55, or equivalent of ABB, Standard
1
-
-
... More
S&F MCB, single pole and neutral, 240 Volts , 20-63 Amps all as specified and as directed. Make : Havells/Legrand/Philips
12
-
-
... More
S&F MCB singal pole 240 Volts , 6 to 32 Amps all as specified and as directed. Make : Havells/Legrand/Philips
56
-
-
... More
S&F MCB singal pole 240 Volts ,20 to 63 Amps all as specified and as directed. Make : Havells/Legrand/Philips
24
-
-
... More
Taking down and hanging during point wiring of ceiling fan/exhaust fan of any size and sweep in proper manner and making connection withT 3 core copper cable including painting all as per specified and directed by Engr-in-Charge
40
-
-
... More
sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 4 Sqmm, earth continuity conductor of size 4 Sqmm to be drawn through and including PVC casing capping/Conduit not less then 32/25mm dia medium Grade fixed on walls/roof/floors all as directed by Engineer in Charge.
Notes:- Two wires of 4 sqmm and one wire of 4 sqmm for earthing and one run of PVC casing capping/Conduit shall be measured as one unit.
274
-
-
... More
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in gound (Earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connecting to the galvanised iron earth lead wire of 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and earht strip protected by provision of GI light grade pipe 15 mm light grade bore including provision of pit in PCC (1:2:4) type B-1 using 20 mm graded of stone aggregate with PCC cover including 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate common salt and charcoal (not less than 40 Kgs, 80 Kgs each) filling with fixing arrangement funnel wire mesh and earth work in hard dense soil returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electircal plate No 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion.
2
-
-
Evaluation Notes How It Works ?