Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date15 Jul 2024
Closing Date5 Sep 2024
Tender Amount₹ 45,00,000
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_666075_1Bid Award Id
ViewTender No
8565/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M & L for applying APP (Atactic Poly Propylene) bitumen membrane 3mm thick APP modified weight not less than 3.60 Kg/Sqm reinforced with non woven polyester fibre of weight 160 gms/sqm as center core and without multiple layers of polyethylene, finished on top and bottom with 7 micron thick flammable polyethylene, applied by thermo fusion using LPG torch on the bottom portion of the membrane, after applying a coat of bituminous primer 0.40Kg/Sqm over roof (An overlap of 100mm & 150mm shall be provided on sides and ends respectively) complete all as per manufacturers instructions. Finally, painting with a coat of bituminous aluminium paint @100gms / Sqm complete all as specified & directed.
2500
-
-
... More
M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry in CM 1:3 complete all as specified and directed
50
-
-
... More
M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out, and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 ( by weight) complete all as specified and directed
50
-
-
... More
M&L for Hydraulically pressed burnt clay tile plain of size 200x200x19/20mm machine made laid over & including 20mm thick screed bed or bedding layer in CM 1:3 mixed with liquid water proofing compound and jointed, pointed in neat cement slurry mixed with 5% crude oil by weight of cement.
50
-
-
... More
Making hole and M&L for fixing nozzles in construction joints/whereas required and patching the joint with cement sand mortar and grouting or other equivalent with pressure pump 40-60 PSI in the nozzle thus fixed with cement slurry admixed with Non shrink polymeric grouting compound complete all as specified and directed.
Make : Pidilite or equivalent make as approved by GE.
2500
-
-
... More
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises
500
-
-
... More
M&L Coloured ceramic tiles in vertical surface 300x200mm x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tile laid over and including 10 mm thick backing coat in CM 1:4 all as directed.
260
-
-
... More
M&L non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tiles exc 0.06 sqm but not exc 0.11 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with colour of tiles laid over and including screed bed or bedding layer 15mm thick in CM 1:4 complete all as specified and directed.
240
-
-
... More
Demolition of cement concrete unreinforced of any description and in any position, not otherwise specifically provided for as in sunken floors and similar of locations complete all as specifified and directed
5
-
-
... More
M & L PCC M-5 grade (nominal mix) using 40mm graded aggregate as in mass concrete or as in sunken floor complete all as specified & directed
5
-
-
... More
M&L for waterproofing treatment to RCC sunken slab complete all as specified & directed by Engineer-in-Charge. Make: PIDILITE or equivalent make as approved by GE.
240
-
-
... More
Clean the sunken portion of toilet/Bath/WC/Kitchen throughly to remove laitance, dirt, dust, etc.
-
-
-
... More
M&L for making hole and fix 12mm dia GI Nozzle @0.5 mtr c/c on the entire area of sunken portions and applying chemical injection grouting through the nozzles with cement slurry admixture with dr fixit bath seal grouting or other equivalent with pressure pump in 40 PSI.seal off the nozzleand cutting the same after grout has set complete all as specified and directed by Engr-in-Charge
-
-
-
... More
Form angle fillet of size 40 mm x 40 mm thick cement sand mortar (1:3) admixed with diluted ("Dr Fixit" Pidicrete URP" or equivalent) as per manufacturer instruction.
-
-
-
... More
Wet the surfaces with water to make it saturated surface dry condition
-
-
-
... More
Sanitary pipes entering through walls and floor shall be sealed with " Dr Fixit Bathseal Tape" and the gaps to be grouted with non-shrink cementitous grout " Dr Fixit Bathseal Grout" or eqvt .Nahani traps , etc to be fitted securely and the gaps around it to grouted in the same manner.
-
-
-
... More
Ponding test for water leakage will be carried as per IS 3370 part 1 instructing
-
-
-
... More
Applying 20 mm thick plaster in C:M 1:3 mixed with water proofing compound 3% by weight of cement or as per manufacturer instruction
-
-
-
... More
Plumbing works to be provided according to proper level&slope seal off the pipesand back fill the gap properly and provide 40mm Outer dia UPVC spout pipe at the lowest point with 300mm projection beyond the outer face of the wall.
-
-
-
... More
M&L for the tile joint chemical cleaning and re-grouting carefully by washing the existing tille with heavy duty tile cleaner again washing with fresh jet water, scratching the joints and filling the same with (white / matching colour) epoxy tile grout curing, cleaning the surface etc, complete all as directed by Engr-in-Charge.
Make : M/s Pidilite or equivalent make as approved by GE.
400
-
-
... More
S&F plain 145 gsm fibre glass mesh and apply one coat of Acyrylic polymer modifed cementious slurry coating by brush and cover it with 100 mm overlap both ways after necessary preparation of surface when it is still wet complete all as per manufacturers instructions. Apply second coat of the same coating on the angle fillets and allow it to dry completely and turned upto 150mm from FFL at Bath/WC /Kitchen area's and all as per instruction complete all as specified and directed by Engineer-in-Charge.
Make : Dr Fixit Bathseal Plus or equivalent make as approved by GE.
300
-
-
... More
M&L for providing water proofing plaster at the junction of wall and slab at chajjas, lintels etc, of average thickness 20mm in CM 1:3 mixed with liquid WPC as per manufacturers instructions & finishing the surface even and smooth without using extra cement all as specified and directed.
Note : Liquid WPC shall be measured & paid seprately under relevant item of this BOQ.
200
-
-
... More
M&L for applying two coats fibre reinforced elastromeric liquid applied water proofing membrane coating over a coat of prime seal on roof complete all as specified and directed by Engineer-in-charge.
Make :Dr Fixit Prime seal or equivalent.
200
-
-
... More
Taking down cement plaster in any description incl racking out joints hacking for key and scrubbing down with water etc complete all as specified and directed
60
-
-
... More
M & L 15 mm thick rendering on fair faces of brickwork / concrete surface on wall in CM 1:4 using WPC @ 3% by weight of cement, all as specified and directed Note:- WPC shall be measured seperately.
60
-
-
... More
M&L for preparation of newly plastered surfaces and applying two coats of weather proof acrylic exterior grade paint (100%) Acrylic over one coat of self primer including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and directed by Engr-in-Charge.
60
-
-
... More
Taking up or down steel tubing of 15 mm bore and connections, including cleaning for re-fixing or removal to store
120
-
-
... More
Taking up or down steel tubing of 20 mm bore and connections, including cleaning for re-fixing or removal to store
120
-
-
... More
Supplying & laying in trenches 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 conforming to IS 1239 (Part-2): 2011 complete all as specified and directed by Engr-in-Charge.
80
-
-
... More
Supplying & laying in trenches 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 conforming to IS 1239 (Part-2): 2011 complete all as specified and directed by Engr-in-Charge.
80
-
-
... More
Re-fixing 15mm bore old steel water tubing and connections in new or old position of walls, ceiling, floors etc with new fittings complete. Note: Serviceable pipes obtained shall be re-used
40
-
-
... More
Re-fixing 20mm bore old steel water tubing and connections in new or old position of walls, ceiling, floors etc with new fittings complete.
Note: Serviceable pipes obtained shall be re-used
40
-
-
... More
S & F in repairs water closet (Squat Pattern) complete incl provn of lime concrete bedding Orissa pattern size 580 x 440mm white integral foot rests (excluding flush pipe or flushing cisterns) including connection to trap and flushing pipe anti syphonage pipe etc complete and making good to floor.
6
-
-
... More
S&F in repairs Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including connection to trap and flushing pipe anti syphonage pipe etc complete and making good to floor.
24
-
-
... More
S&F in repairs PVC low level flushing system 10 Ltr capacity with flush pipe complete all as specified and directed.
30
-
-
... More
S & F in repairs stopvalves cast copper alloy screwed down high pressure withcrutch or butterfly handle screwed both ends for iron pipe 15 mm dia complete all as specified and directed.
60
-
-
... More
S&F in repairs two way bib tap 15mm chromium plated complete all as specified & directed by Engineer-in-Charge.
30
-
-
... More
S&F in repairs grating square or circular 125mm dia of PTMT (minimum weight 100 gms, complete all as specified and directed.
40
-
-
... More
Taking down drain pipes (any size or pattern), including all fittings, T, bends,etc., including cleaning or refixing (measured overall as fixed along the centre line over fitting and accessories)
200
-
-
... More
S & F 110mm thick PVC (SWR) pipes Type 'A' single socketed, in any length with rubber ring joints fixed on wall complete all as specified and directed
120
-
-
... More
S & F 75mm thick PVC (SWR) pipes Type 'A' single socketed, in any length with rubber ring joints fixed on wall complete all as specified and directed
80
-
-
... More
S&F PVC (SWR) 110mm dia bends any radius complete all as specified and directed.
24
-
-
... More
S&F PVC (SWR) branch 110mm bore pieces, single (single Y) equal or unequal all as specified and directed.
24
-
-
... More
S&F PVC (SWR) 75 mm dia bends any radius complete all as specified and directed.
24
-
-
... More
S&F PVC (SWR) branch 75 mm bore pieces, single ( single Y ) equal or unequal complete all as specified and directed.
24
-
-
... More
Supply & Fixing in repairs viterious china wash basin white flat back size 550 x 400 mm excluding taps waste chain and plug and porcelain stopper but incl necessary brackets CP wastes and other fittings complete all as specified and directed by Engineer-in-Charge
15
-
-
... More
S&F in repairs pillar taps chromium plated cast copper alloy with capstan heads screwed down high pressure with or without lettered Hot Or Cold Withlong screwed shanks and fly nuts screwed for iron pipes 15mm dia complete all as specified and directed
15
-
-
... More
S&F in repairs fancy type bib taps chromium plated with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule 15mm dia complete all as specified and directed by Engineer-in-Charge
20
-
-
... More
S&F of PVC connections 15mm size with brass nut on both end washers of length 450mm complete all as specified
40
-
-
... More
M&L for cutting holes into or through cement concrete slabs, chajjas, etc. reinforced or otherwise n.exc 100 sq.cm complete all as specified and directed
50
-
-
... More
M&L for cutting holes into or through cement concrete slabs, chajjas, etc. reinforced or otherwise exc 100 sq.cm and n.exc 250 sq.cm complete all as specified and directed
50
-
-
... More
Demolition of brick work, PCC block mansonry or stone boulder masonary built in cement mortar including all quoins arches pillars etc. but excluding ashlar facing dressed stone work and precast concrete articles.
1.5
-
-
... More
M&L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed at any height
1.5
-
-
... More
S&F Solid PVC door frame of size 50mm X47 mm made out of 5mm plain colour PVC sheet rinforced with MS Square tube suppling and fixing in opening as per specification and drawing.
50
-
-
... More
S&F Factory made solid panelFactory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete including all neccesary fittings all as specified and directed.
15
-
-
Evaluation Notes How It Works ?