Military Engineer Services Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Electrical and Electronics
Electrical Works
Eprocure
Opening Date13 Dec 2022
Closing DateCancelled
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Exhaust Fan,Pedestal fan,wall fan, table fan 300/400 mm Sweep.

20

-

-

... More
Exhaust Fan, Pedastal fan,wall fan, 450/600 mm Sweep.

10

-

-

... More
Painting only of ceiling fan,exhaust fan,wall fan,pedestal fan for any size and type, scraping out of old paint, filling of cavities with filler, preparation of body and cleaning of dust etc Painting by Spray with first Quality Paint including over coat of zinc primer, indl writing the MES number complete for all as directed

1000

-

-

... More
Overhauling of Ceiling Fan, Exhaust Fan, Wall Fan,Table fan,Pedestal Fan any Make & any Sweep including dismantling/opening of body, cleaning of body, oiling, greasing & reassembling complete, replacing of split pin, nut , bolts etc and testing Note : Spares shall be measured & paid in resperative items of this sch.

500

-

-

... More
Supply only spare parts to be incorporated for repairing fans in respective item of this schedule

-

-

-

... More
Capacitor up to 2.5 Mfd MAKE KELTRON,EPCOS

400

-

-

... More
Capacitor 3.15/ 4 MFD MAKE KELTRON,EPCOS

25

-

-

... More
Capacitor Clamp of all sizes with Connector As Par Sample

425

-

-

... More
Rubber Insulator sutiable for any type of Ceiling Fan.

1130

-

-

... More
Mild steel Down Rod 600 mm Long with Clamp nut bolts & split pin as par sample

10

-

-

... More
Mild steel Down Rod with Clamp nut bolts& split pin for 900 mm Long as par sample

20

-

-

... More
Exhaust Fan bracket with frame Nut, Bolt, Rubbers etc mplete 300 mm sweepas par sample

5

-

-

... More
Exhaust Fan bracket with frame Nut, Bolt, Rubbers etc complete 380/ 450 mm sweepas par sample

5

-

-

... More
Ball bearing sutiable for any type of fans Make : SKF,TATA,NBC

450

-

-

... More
Mild steel shaft as per sample for any fan

60

-

-

... More
Ceiling Fan Blade suitable for 1200/1400 mm sweep as per sample.

25

-

-

... More
Exhaust Fan Blade suitable for 300 mm sweep as per sample.

10

-

-

... More
Exhaust Fan Blade suitable for 450 mm sweep as per sample.

20

-

-

... More
Pedestal/Wall Fan Blade suitable for 450 mm sweep as per sample.

12

-

-

... More
Pedestal / Wall Fan Blade suitable for 600 mm sweep as per sample.

2

-

-

... More
Supply & Fix Exhaust fan louvers with shutter made of aluminium sheet of 0.5 mm thickness, and frames made out of mild steel, making good the distrubed surfaces in CM 1:4, including scafolding if any required to carry out the work in building of height up to 32 Meters complete in all respects.

90

-

-

... More
Deployment of Technician for checking fan, Fan Servicing / Safety Hook/ Pin including fixing of safety pin, nut, bolt etc. complete and entry in register duly signed by User/ Occupants.Technician will Carry scheduled preventative maintenance checks as per details to be given by Site Executive.

600

-

-

... More
M & L for Opening switch board mounting plate at height upto 1.5m and replacing of old unserviceable piano switch 5 Amps & refixing switch plate and testing complete all as directed. Note (i) The representative of the contrcator shall report to Engineer-in-charge/JE and carry out repairs on daily basis be rectified on the same day Make - Anchor, Leader, Plaza

500

-

-

... More
M & L for Opening switch board mounting plate at height upto 1.5m and replacing of old unserviceable fan regulator & refixing switch plate and testing complete all as directed. Note (i) The representative of the contrcator shall report to Engineer-in-charge/JE and carry out repairs on daily basis be rectified on the same day Make - Anchor, Leader, Plaza

350

-

-

... More
S&F,in repair PVC laminated ISI marked top cover 3 mm including cutting/drilling holes for mounting housing of switches, sockets, etc as per site requirement suitable for following sizes of sunken/TW board. 4”x4” size

10

-

-

... More
All as per Item No 10.00 here-in-before but 7”x4” size

10

-

-

... More
All as per Item No 10.00 here-in-before but 8”x6” size

10

-

-

... More
All as per Item No 10.00 here-in-before but 8”x10” size

10

-

-

... More
All as per Item No 10.00 here-in-before but 10”x12” size

10

-

-

... More
M & L taking down from position existing defective storage water heater 25 to 50 ltr Capacity for carrying out repairs work such as replacing worn out parts and fixing back in position in replacing the necessary nuts and bolts including disconnecting & reconnecting water & electric supply lines, testing, painting with two coats of white synthetic enameled paint by spray paint with spray gun complete all as specified and directed

30

-

-

... More
Supply only safety valve for geyser chromium plated brass 15 mm dia all as specified and directed Make :- Racold/ Bajaj

10

-

-

... More
Supply only non return valve chromium plated brass 15 mm dia heavy-duty all as specified and directed Make :- Racold/ Bajaj

10

-

-

... More
Supply only indicator lamp for geyser red/green, round/square/rectangle as per site requirement 230 V AC all as specified and directed Make :- Mimic / AE

20

-

-

... More
Supply only heating element 1500 watt threaded or push type as per the existing one suitable for vertical storage water heater of any size all as specified and directed Make :- Racold/ Bajaj

16

-

-

... More
Supply only heating element 2000 watt threaded or push type as per the existing one suitable for vertical storage water heater all as specified and directed Make :- Racold/ Bajaj

10

-

-

... More
Supply only thermostat suitable for storage water heaters 25 to 50 Ltrs capacity adjustable type i.e.. 0 degree centigrade to 80 degree centigrade all as specified and directed Make :- Racold/ Bajaj

20

-

-

... More
Supply and fix only plug top 3 pin 5 Amps capacity Make: Anchor ISI/LeaderISI/RIDER ISI

25

-

-

... More
Supply and fix only plug top 3 pin 15/16 Amps capacity Make: Anchor ISI/LeaderISI/RIDER ISI

25

-

-

... More
Supply and fix in repairs cable flexible 3 core PVC insulated and pvc sheathed with multi stranded copper conductor size of 0.75 sqmm 1100 volts grade all as specified and directed. Make Plaza, Havells

200

-

-

... More
Supply and fix in replacement of copper water tank of 25 Ltrs capacity with and including necessary gasket packing, nuts, bolts, etc complete all as directed by Engr-in-Charge.

10

-

-

... More
Fabricating, supply and fixing in replacement geyser bottom cover duly painted in two halves suitable for vertical type storage water 25/50 Ltrs capacity for geysers of any make as per the existing one all as specified and directed

10

-

-

... More
Supply & Fix in replacement flexible 15 mm dia PVC pipe for cold water of geyser with PTMT nuts on both ends of length 450mm with two washers, all as specified and directed

25

-

-

... More
Supply & Fix in replacement flexible 15 mm dia PVC pipe for hot water of geyser with PTMT nuts on both ends of length 450mm with two washers, all as specified and directed

25

-

-

... More
Supply and fixing in repairs Sheet Metal enclosure with 2 pin and earth plug and socket complete with one single pole MCB SP of Capacity upto 20 Amps 240 Volts

15

-

-

... More
Taking down old unserviceable High bay, Mid Bay, Flame Proof light fittings from walls/Builings/Sheds/Ceiling height up to 10 Meter incl repairs and replacement of burnt/worn out accessories and refixing the same in existing position including testing of fittings after repair, testing of connected wiring complete all as directed by Engineer in charge . Note :- (a) T & P, Ladder for any height etc are deemed to be included in the quoted rate. (iii) The representative of the contrcator shall report to Engineer-in-charge/JE and carry out repairs on daily basis during the contrcat period and the defect shall be rectified on the same day (iii) A penal recovery of Rs 500 Per Day Per Complaint for not attening the compalint will be recovered

47

-

-

... More
Supply & fix in repairs LED Highbay light fittings 150 watts, Energy saving, environment friendly & robust open type vertical Highbay LED IP 66 luminaire including driver and required GI tube down road of length up to 2 meter with hoooks for hanging the fitting. The fitting including fixing arrangements and taking down old rusted bracket fittings complete etc. Make :- Crompton / Havells /Bajaj Note : Fittings shall will be installed in Hangers/Sheds, height up to 10 Meters only and directed by Engr-in-Charge.

19

-

-

... More
S & F in repair/replacement of LED Driver 60 Watt Suitable for street light fitting, Security light and flood light. Make :- Crompton/ Havells /Bajaj

12

-

-

... More
S & F in repair/replacement of LED Driver 30/35 Watts Suitable for street light fitting, Security light and flood light. Make :- Crompton/ Havells /Bajaj

11

-

-

... More
Supply & fix in repairs very high efficiency round LED Highbay light fittings 150 Watt in PDC housing, IP 66 luminaire including driver and required GI tube down road of length up to 2 meter with hoooks for hanging the fitting including fixing arrangements and taking down old rusted bracket fittings complete etc. Make :- Crompton / Havells /Bajaj. Note : Fittings shall will be installed in Hangers/Sheds, hight up to 10 Meters only and directed by Engr-in-Charge.

18

-

-

... More
S&F in repair of building Security light fitting 35 Watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07including fixing arrangements and taking down old rusted bracket fittings complete all as per directed by Engr- in – charge. Make:- HAVELLS/ PHILLIPS/ JAQUAR/ WIPRO/BAJAJ

20

-

-

... More
Material and Labour for checking of panels, DB's, Junction Box, including cleaning with blower, clamping of lugs as per existing size and capacity complete all as specified and directed.Technician will Carry scheduled preventative maintenance checks as per details to be given by Site Executive.

600

-

-

... More
S & F in replacement MCCB 63 Amps, 25 KA Triple Pole 415 Volts including connecting up complete in existing panel with lugs/ Glands all as specified and directed.

1

-

-

... More
S & F in replacement MCCB 100 Amps, 25 KA Triple Pole 415 Volts including connecting up complete in existing panel with lugs/ Glands all as specified and directed.

1

-

-

... More
S & F in replacement MCCB 200 Amps, 36 KA Triple Pole 415 Volts including connecting up complete in existing panel with lugs/ Glands all as specified and directed.

1

-

-

... More
S & F in repair MCCB 250 Amps, 36 KA Triple Pole 415 Volts including connecting up complete in existing panel with lugs/ Glands all as specified and directed.

1

-

-

... More
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth and getting out in in soft / lose soil

105.94

-

-

... More
Returning filling in , excavated soil including spreading, leveling and well ramming in layers not exc 25cms each any type of soil.

54.06

-

-

... More
Removing the excavated materials not exc 50mtr and depositing where directed at a level not exceeding 1.5 mtr above the staring point all as directed by Engr - in- Charge.

51.28

-

-

... More
M&L for sand cushioning by spreading in trenches stone cursh sand by gently by punning down manually as in cable protection all as specified and as directed by Engr-in-Charge.

40.55

-

-

... More
Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified..

3029

-

-

... More
Taking down existing UG cable and supply & Lay XLPE insulated, heavy duty 1100 volt grade electric armoured LT UG cable with aluminium conductor of size 95 Sqmm 3.5 Core in trenches/along the wall/including making all connections, saddles, spacersincluding scaffolding if any required for saddling the cable in walls of building of height up to 25 meter, complete wih aluminium lugs as required at site and as directed by Engr-in-Charge

200

-

-

... More
Supply and fixing 36 Watt All in one integrated Solar Street Light fitting with complete system with Battery Lithim ion, 11.1 V, 39.6 AH including braket and including taking down old unserviceable fitting with fixing assembly complete all as directed by Engineer in Charge. Make : Sai Indutrial alliances pvt ltd/ Crompton/ Bajaj as approved by GE

2

-

-

... More
Comprehensive Repairs and maintenance of Fire alarm system installed at NAD Trombay, the system comprises of main Fire alaram Control Panel with battery back up, Repeter panel , Motor operated Sirems, Manual call Points installed at various location complete.

20

-

-

... More
Comprehensive Repairs and maintenance of Fire alarm system inslalled at 31 WEU Thane. The system comprises main Fire Alarm Control Panel ith battery back up, Manual Call Point (MCP), Electronic Hooter, Heat Cum Smoke Detector, Remote Response Indicators, installed at various locations complete,

20

-

-

... More
Comprehensive Repairs and maintenance of Fire alarm system inslalled at Naval Station Thane. The system comprises main Fire Alaram Control Panel with battery back up, Manual Call Point (MCP) , Electronic Hooter, Heat/Smoke Detector, Remote Response Indicators, installed at various locations complete.

20

-

-

... More
Comprehensive Repairs and maintenance of Fire alarm system inslalled at NCN Thane. The system comprises main Fire laram Control Panel with battery back up, Manual Call Point (MCP) , Electronic Hooter, Heat/Smoke Detector, Remote Response Indicators, installed at various locations complete.

20

-

-

... More
Comprehensive Repairs and maintenance of Fire alarm system inslalled at TS Mahul. The system comprises main Fire laram Control Panel with battery back up, Manual Call Point (MCP) , Electronic Hooter, Heat/Smoke Detector, Remote Response Indicators, installed at various locations complete.

20

-

-

... More
Comprehensive Repairs and maintenance of Fire alarm system inslalled at DSRV. The system comprises main Fire laram Control Panel with battery back up, Manual Call Point (MCP) , Electronic Hooter, Heat/Smoke Detector, Remote Response Indicators, installed at various locations complete.

20

-

-

... More
Comprehensive Repairs and maintenance of Fire alarm system inslalled at T7 CMT Complex The system comprises main Fire laram Control Panel with battery back up, Manual Call Point (MCP) , Electronic Hooter, Heat/Smoke Detector, Remote Response Indicators, installed at various locations complete.

20

-

-

... More
Comprehensive Repairs and maintenance of Fire alarm system inslalled at Single Officer accn, NOFRA. The system comprises main Fire laram Control Panel with battery back up, Manual Call Point (MCP) , Electronic Hooter, Heat/Smoke Detector, Remote Response Indicators, installed at various locations complete.

20

-

-

... More
Comprehensive Repairs and maintenance of Fire alarm system inslalled at Relese Sailor Accn, Tanaji. The system comprises main Fire laram Control Panel with battery back up, Manual Call Point (MCP) , Electronic Hooter, Heat/Smoke Detector, Remote Response Indicators, installed at various locations complete. Note for item ser No 48 to 56 : a) The entire system shall be inspected and checked by the service engineer of the main manufacturer and recommend the replacement of spares and functional parts etc in proper inventory. The replaced parts shall be measured and paid for seperately as supply only under respective items of this schedule but fixing and testing etc is deemed to be included in the unit quoted rate against this item b) Checking of all internal & external wiring for open, Short, Damaged & loose Connections of all MCP, Main fire alaram panel, Repeater Panel, Siren motor, replacing of broken Break glass. Cleaning of Smoke detectors. c) Testing the fire alram system including checking of each MCP and maintining serviceablity records on monthly basis. d) All main fire control including battery, smoke detector, temperature heat detectors, connected control wiring etc shall be checked for normal functioning.

20

-

-

... More
Supply & fixing in repairs flame proof manual call point (MCP) Housing with 24 Volt addressable MCP card and hammer, including making addition/alternation to existing suppors of MCP. Make - ANG FPA or , PCD Fire System, Safetech, Zicom, Apollo.

6

-

-

... More
Supply & fixing in repairs Switch Mode Power supply operating at input volatage range 180 to 270 Volts and having maximum out put volatage of 28.5. Make - Proxymon/Omron

4

-

-

... More
Supply & fixing in repairs maintenance free 12 Volts 15 AH battery suitable for fire alaram panel Make - Exide, Amron,Amco

5

-

-

... More
Supply & fixing in repairs maintenance free 12 Volts 26 AH battery suitable for fire alaram panel Make - Exide, Amron,Amco

5

-

-

... More
M & L for Removing of burnt electric motor 1 HP to 3 HP, 440 Volts of fire alaram siren after dismantling of all electrical connections & transporting from site to workshop, rewinding of electric motor with super enameled copper wire after removing of old burnt coil, replacing of bearing, cleaning of slots properly, heating in heat chamber after varnishing and testing at site and including scrapping the old paint and applying one coat of red oxide primer and applying two coat of synethetic enamel paint. all as directed by Engineer-in-Charge. Note :- Cost of insulation paper, varnish and any nuts, bolts and lugs required for the job shall be deemed to be included in the quoted rate

1

-

-

... More
Supply & fixing in repairs Detectors complying with and type certified to EN-45 type multisensor detector with heat and smoke combination photo electirc / optical with base with self built intelligence as per IS - 11360 complete. Make - Apollo/Zicom/Hochuki/Edward/PCD/Safetech,

10

-

-

... More
Supply & fixing in repairs DOLstarter 3 Phase 440 volts suitable for 2 HP fire alaram siren motor Make “Siemens / L&T /ABB ” as existing in panel board.

1

-

-

... More
Supply & fixing in repairsresponse indicator complete with cable connection testing and commissioning all as specified and directed by Engr-in-Charge. Make - Apollo/Zicom/Hochuki/Edward/PCD/Safetech,

20

-

-

... More
Supply & fixing in repairs Electronic hooter 24 Volt DC complete for fire alaram system complete with acessories all as directe by engineer-in charge Make - Safetech, Minimax, ECD, Apollo, Zicom/PCD

10

-

-

... More
Supply & fixing in repairs conventional manual call point with pill box complete with hammer, chan and all fixtures Make - Safetech, Minimax, ECD, Apollo, Zicom/PCD

10

-

-

... More
Laying only un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified..

900

-

-

... More
M & l for taking down of old sables & Supply & lay armoured XLPE Insulated 1.5 Sqmm 4 core multi stranded copper conductor cable along the walls, in trenches ducts, ceiling / connection to control panel, manual call point complete with termination, testing and commissioning all as specified and directed by Engr-in-Charge. Make - Poly Cab/Havells/Plaza

100

-

-

... More
M & l for taking down of old sables & Supply & lay armoured XLPE Insulated 1.5 Sqmm 2 core multi stranded copper conductor cable along the walls, in trenches ducts, ceiling / connection to control panel, manual call point complete with termination, testing and commissioning all as specified and directed by Engr-in-Charge. Make - Poly Cab/Havells/Plaza

100

-

-

... More
M&L for reinforced cement concrete nominal mix M-20 (using 20mm graded stone aggregate) for foundations, including rafts, footings, foundation beams, plinth beams, bases for column etc and mass concrete, complete all as specified and directed. (Note - Reinforcement and form work will be measured and paid separately).

7.56

-

-

... More
M & L for TMT bars of Fe-500 D grade conforming to is:1786, 10 mm dia & over, including cutting to length, bent to shape equired, cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc, complete all as specified and directed.

75

-

-

... More
M & L for TMT bars of Fe-500 D grade conforming to IS: 1786, 8 mm dia bars as in binders, spacers, strippus including cutting to length, bent to shape required, cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc, complete all as specified and directed.

79.95

-

-

... More
M & L for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams , side and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter, for rough finished surfaces of concrete, complete all as specified and directed.

13.44

-

-

... More
Dismantling of old UNSV/rusted steel tubular poles 9 mtr long necessary disconnecting cables/over head condcutor and removing unserviceable pole from site complete all as specified and directed.

15

-

-

... More
Supply, Fixing and connection of hot dip galvanised octagonal poles of height 6 mtr with 130 mm bottom A/F & 70mm top A/F made up of 3mm thick HT sheet along with base plate of size 200 x 200 x 12mm thick including 4 nos of M20 x 600 long J type foundation bolts and 1 mtr long hot dip galvanised single arm standard bracket, including MCB of 6 Amps, with connector 4 way to be provided as termination point complete all as specified and directed. Make :- Bajaj

15

-

-

... More
M&L for provn of Earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the plate not less than 2.50 M below normal GL, connected to Galvanized earth strip 32x6mm upto 7.5 mtr with protection pipe by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 40mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I 2009 specification.

21

-

-

... More
Supply & fix in repair 3 core 1.5 Sqmm size multistranded FRLS copper conductor PVC unsheathed 650 / 1100 Volt cable for interconnection of cable looping box to Street Light Fitting all as Directed.

110

-

-

... More
Supply, laying, connecting and testing XLPE insulated (Earthed) cable in trenches/or fixed on pole etc in screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volt grade, cross sectional area 16 Sqmm, 4 Core Conforming to IS-7098 (Part-II)-1985 complete .

110

-

-

... More
M&L for cutting existing road/hard, dense soil not exc 45x60 cm in wide & depth getting out excavated material for laying GI tube returning filling & well ramming watering finish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil all as directed

10

-

-

... More
S & F in replacement of security light fitting/Building security light LED type 60 watts, THD10%, Efficacy 110 Lm/w with Pressure die cast aluminium housing with hight power LED as lighting source and lens embedded PC cover having TOP OPENING seerated driver compartment with IP 66 protection and impact resistance of IK07 with 10KV built-in surge protection device etc all as directed by Engineer in charge. Make:- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO/ HAVELLS.

30

-

-

... More
Taking down copper/ aluminum point wiring (Light/Fan/Socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces to walls floors etc.

720

-

-

... More
M & L for point wiring complete with proper colour coding with 1100 Volts grade, 1.5 Sqmm PVC insulated FRLS, unsheathed, wire confirming to IS-694, Part II, ISI marked with multistranded copper conductor drawn in and including PVC concealed conduit of suitable size of wall/ RCC slab/ ceiling/ colunms/ beams etc with all accessories, fittings, PVC junction boxes etc, for mounting modular switches, sockets, fan regulators etc, also including 1.5 Sqmm, PVC insulated, FRLS unsheathed, 1100 Volts multistranded copper conductor green colour as contineous earth wire connected to common earth dolly for one light point/fan/bell point controlled by one way switch, complete all as specified and directed. Note : Rates included for concealed cutting as required at site without any damage and making good in CM 1:4 and matching the surface as required 2 all screws and washer for point wiring shall be Stainless steel. Nothing is extra shall be admisible on this account

60

-

-

... More
All as per Item No 82.00 here-in-before but one 5A 2pin/3pin socket out let multipurpose on the same board with other switches.

50

-

-

... More
All as per Item No 82.00 here-in-before but one 5A 2pin/3pin switch socket out let multipurpose on independent Board.

50

-

-

... More
All as per Item No 82.00 here-in-before but wiring complete with 2.5 Sqmm for 3 pin 15A socket multipurpose on independent board complete all as specified and directed.

50

-

-

... More
Supply and fixing round shape LED Downlighter, 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. Make : Shakti/Crompton/Havells

20

-

-

... More
Supply and fixing round shape LED Fency Spot Light, 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete.Make Shakti Cat No. SZRDMX015 or equivalent of Crompton/Havells as approved by GE

10

-

-

... More
M&L for sub main wiring with two single core 4.0 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC casing caping with and including PVC insulated 4 Sqmm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed. (Make :- PRESFIT/ PRECISION - Casing caping), (Make :- FINOLEX/ KEI/ POLYCAB - PVC Copper wire) Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping of 4.0 sqmm will be measured and paid one unit.

150

-

-

... More
M&L for sub main wiring with two single core 1.5 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC casing caping with and including PVC insulated 1.5 Sqmm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed. (Make :- PRESFIT/ PRECISION - Casing caping), (Make :- FINOLEX/ KEI/ POLYCAB - PVC Copper wire) Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping of 1.5 sqmm will be measured and paid one unit.

110

-

-

... More
Taking down carefully point wiring of any type & pattern (Light/Fan/Socket or power) including fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings of any type etc and making good disturbed surfaces of walls/ roof etc, complete all as specified and directed.

270

-

-

... More
M & L for point wiring with PVC insulated FRLS unsheathed 1100 Volts grade single core multistranded copper conductor cable 1.5 Sqmm drawn in and including PVC casing-caping, fixed on wall / ceiling with all accessories, fittings, PVC junction boxes etc, with suitabe sunk pressed steel boxes for modular fittings not less than 1.6 mm thick, etc with necessary fixing accessories and earth continuity conductor cable of 1.5 Sqmm size connected to common earth and earth dolly including 1.6 mm thick pressed steel terminal boxes concealed in wall covered with laminated sheet top cover 3 mm thick for mounting switches / sockets / fan regulators fixed with Cadmium plated machine screws all as specified for one light / fan / bell point controlled by one switch.

500

-

-

... More
All as per Item No 91.00 here-in-before but for one 5A 2pin/3pin socket out let multipurpose on the same board with other switches.

60

-

-

... More
All as per Item No 91.00 here-in-before but for one 5A 2pin/3pin switch socket out let multipurpose on independent Board.

110

-

-

... More
All as per Item No 91.00 here-in-before but wiring complete with 2.5 Sqmm for 3 pin 15A socket multipurpose on independent board Note for item No. 91.00 to 94.00 : A penalty of Rs 100 /- per point will be recovered from the contractor for not matching the disturbed surface with original.

110

-

-

... More
S&F modular type 6A one way SP switch 1 module confirming to IS: 3854-1997 with fingure proof terminal complete all as specified and directed.

200

-

-

... More
S&F modular type 2/3 pin combined shuttered type 6 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed.

80

-

-

... More
S&F modular type 2/3 pin combined shuttered typr 16 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed.

40

-

-

... More
S&F modular type 16 A one way SP switch 1 module confirming to IS: 3854-1997 with finguer proof terminal complete all as specified and directed.

40

-

-

... More
S&F modular type 120W step fan regulator of 2 module size conformng to IS: 11037-1984 complete all as specified and directed.

32

-

-

... More
Supply & Fix Modular Bell push flush type 6 Amp, 1 module, 230 Volts complete all as specified and directed.

5

-

-

... More
Supply and fix bell ding dong AC 230 V single pole. complete all as specified and directed.

5

-

-

... More
S & F Modular Blank plate 1 module suitable for Modular switch boards all as specified and as directed

10

-

-

... More
S & F Modular cover plate 8 modules

20

-

-

... More
S & F Modular cover plate 4 modules

40

-

-

... More
S & F Modular cover plate 3 modules

20

-

-

... More
S & F Modular cover plate 6 modules

7

-

-

... More
S & F Modular cover plate 1 modules

5

-

-

... More
S&F ceiling rose three terminal, 230 Volts PVC / Polycarbonate body, complete all as specified and directed.

250

-

-

... More
S&F in repairs Surface, hanging and wall mounted batten (Double side connection) suitable for LED tube 20/22 watts, 230 volts alongwith tube rod 22 watt (double side connection), including fixing mounting blocks 2 Nos, 15 mm MS conduit, 1.5 sqmm 3 core pvc insulated copper conductor cable including fixing arrangements complete all as specified and directed. Make :- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO

350

-

-

... More
Supply and fixing Electronic Meter 10-60 amps Single phase tamper proof with Class 1 accuracy Optical port,LED Indication for earth leakage ,Elegant Polycarbonate Enclosure,High Surge withstand up To 8kv ,anti tamper features,Electromagnetic compatible & 6 digit Display. Make L&T/ HPL or equivalent as approved by GE. Note : Old unserviceable Meter will be deposit to MES.

10

-

-

... More
M&L for testing of old earthing using calibrated earth tester & submitting result to engr -in -charge all as directed. Note : (i) Watering of earthing with 2 Buckets (30Ltrs) water mixed with salt (total 20Kg) shall be carried out one day before the testing & the cost of the same shall deemed included in unit rate quoted.

70

-

-

... More
M&L for painting on wall with synthetic enameled paint of black colour as background of 200 x 150 mm size and writing for earth test result with date & year all as specified and directed at site by Engineer-in-Charge.

70

-

-

... More
Laying only precast concrete cable cover class LV type in trenches all as specified.

1100

-

-

... More
M&L for locating of faults of LT under ground cable PILCA/XLPE upto 400 Sqmm size by using computerised / primary current injection method including cutting and removing the faulty portion of the cable and jointing with suitable cable joint and testing after jointing all as required and directed at site. Notes:-(i) Excavation, earth work, sand cushioning, PCC cover etc will be measured and paid separately under relevant items of BOQ. (ii) Cable joint will be measured and paid separately. (iii) Additional length of cable required at site for jointing will be measured and paid separately.

5

-

-

... More
M&L for straight through joint (HEAT SHRINKABLE TYPE KITS) for underground cable including joint kits and labour complete for making joints suitable for LT, XLE/PILC/PVC sheathed armoured heavy duty cable with aluminium conductor 3.5/4 core up to to 50 Sqmm incl taking down existing terminal joints.

1

-

-

... More
All as per Item No 115.00 here-in-before but 3.5/4 core 70 Sqmm to 150 Sqmm size -do-

2

-

-

... More
All as per Item No 115.00 here-in-before but 3.5/4 core 185 Sqmm to 400 Sqmm size -do-

2

-

-

... More
Supply & Lay or fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of size 10 Sqmm 4 Core in trenches/along the wall/including takingdown old unsv cable and making all connections complete with lugs as required at site and as directed by Engr-in-Charge. Make - Havells/Polycab/Plaza/KEI.

300

-

-

... More
M&L for cutting existing road/hard standing not exc 45x45 cm in wide & depth getting out excavated material for laying GI tube ;returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil all as directed

35

-

-

... More
S& F in replacement of GI steel tubing light grade 40 mm dia for laying in ground, along the pole in coping, road crossing etc for cabe protection including necessary fittings , clamps for supports, etc all as directed by Engineer in charge Make - Tata/Jindal/Surya Prakash

35

-

-

... More
Supply and fix in replacement of FRP looping box of size 155x210x92 mm with connector, MCB 6 Amps, Din Rail, GI clamps made out of GI flat of size 25mm X 3 mm channel including providing detachable GI 3 mm thick plate inside looping box as cable gland plate and including cable gkands as required at size and making connections all as specified and directed by Engineer –in –Charge.Make - National / Sintex

60

-

-

... More
M&L for taking down old unsv and supply & lay 3 Core 1.5 Sq mm size multistranded copper conductor PVC unsheathed 650 / 1100 Volt Grade As per IS 694 with and including 20 mm dia PVC conduit and passing through PVC conduit with necessary saddle, clamps, bolts & nuts, all For interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc All as Directed.

160

-

-

... More
M&L for Multistandarded Copper Conductor cable of 3 Core 1.5 Sq mm size drawn through steel tubular poles for interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc taking down old unsv cable all as Directed. Make :- Havells/ Polycab/Plaza/KEI

200

-

-

... More
M&L for sub main wiring with two single core 2.5 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC casing caping with and including PVC insulated 2.5 Sqmm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed. (Make :- PRESFIT/ PRECISION - Casing caping), (Make :- FINOLEX/ KEI/ POLYCAB - PVC Copper wire) Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping of 2.5 sqmm will be measured and paid one unit.

200

-

-

... More
M&L in repairs 1 output 16 A-250 V 50/60 Hz Digital Time Switch with Astronomical function 56 for switching on/off lights and other electric devices with daily astronomical calculation of the sunrise/sunset times based on the entered location or location coordinates complete all as directed by Engr-in - Charge .Make legrand Cat No. 412654 or equivalent of L&T/Indo Asian as approved by GE

3

-

-

... More
M&L in repairs for 24 Hrs 240 V FM1 Quartz type Time switches astronomical type (Having longitude and latitude of Indian cities in memory) timer for controlling street lights contactors complete all as directed by Engr-in - Charge .Make :-Legrand/ L&T/Indo Asian as approved by GE

6

-

-

... More
M&L to attend the LED Solar Light fittings of 18 wattage. Service Representative will Carry scheduled preventative maintenance checks as per details given below at Mankhurd a)Solar PV Modules - Check the Circuit Voltage and current characteristics. Also, check the mechanical integrity of the Solar PV Modules. b)Battery Bank -Check the Specific Gravity of the Electrolyte, Electrolyte level, battery terminals, Battery Bank box and adding Electrolyte solution if required. NOTE Electrolyte solution will be measured seprately under this Schedule. c)Solar PCU - Check DC input Voltage and Current, Check AC input Voltage and Current, checking the wiring. d)Module Mounting Structures -Check the mechanical integrity of the Solar PV Modules Mounting Structures. Ensure that there is no corrosion set up on the MMS and the module is firmly fixed. e) System Wiring - Check the system wiring including the insulations, cable lugs and rewiring/soldering ifa any required f)Module Cleanliness - Cleaning of the dust accumulated over the Solar Module, and taking corrective measures

70

-

-

... More
M&L for preparation of old painted surfaces of Solar Street Light Poles including acessories by scarping old paint and applying two coats of paint including numbering of pole with black oil paint all as directed by Engineer in Charge

20

-

-

... More
Supply and fix in replacement of LED 18 watt DC solar light fitting Make - Emvee / ICPC Solar

8

-

-

... More
Supply and fix inreplacement of low maintenance VRLA lead acidic battery of 120 AH suitable for 1 x 18 watt Soalr Light fitting all as per recommanded by Manufracturer

3

-

-

... More
Supply and fix inreplacement of charge controller suitable for 18 watt Solar Light fittings incluing any wiring as required

10

-

-

... More
Supply only electrolyte solution to be incorporated in servicing, suitable for Solar charged battery of any capacity.

400

-

-

... More
Supply and fix in replacement street light fittings in street light poles/Buildings the fitting shall be of LED type 60 Watts complete with and including drivers, pressure die cast aluminium housing, prewired complete. Make-Havells/Crompton/Bajaj.

20

-

-

... More
Supply and fix in replacement flood light fittings in street light poles/Buildings the fitting shall be of LED type 120 Watts complete with and including drivers, pressure die cast aluminium housing, prewired complete. Make-Havells/Crompton/Bajaj.

3

-

-

... More
Dismentling of PCC foundation / pole coping from ground level all as per specified.

4.56

-

-

... More
M & L for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work complete all as specified and directed.

4.56

-

-

... More
Supply and fix in replacement 8/9 Watt LED Bollard garden light fitting with efficient high output COB LED, pressue die cast powder coated housing with PC diffuser driver nut bolt ,washer base plate foundation 0.3 mtrx0.3 mtr x.40 mtr by PCC 1:2:4 type B-1 using 20mm grade stone aggegates of size including excavtion and earth work , provision of GI bend of size 50MM dia in the PCC for cable entry all as specified and directed in EIC. Make:- HAVELLS/ PHILLIPS/ JAQUAR/ WIPRO/BAJAJ.

30

-

-

... More
Suply and fix New generation , Post-top LED warm light 35/40 W,energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LEDs as light provision of GI bend of size 40 mm dia in the PCC for cable entry the fitting with nut bolts,washer all as specified and directed in EIC. Make:- HAVELLS/ PHILLIPS/ JAQUAR/ WIPRO.

10

-

-

... More
Suply and fix New generation , Post-top LED warm light 15/ 20 W,energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LEDs as light provision of GI bend of size 40 mm dia in the PCC for cable entry the fitting with nut bolts,washer all as specified and directed in EIC. Make:- HAVELLS/ PHILLIPS/ JAQUAR/ WIPRO.

10

-

-

... More
Taking down of Old MCB DB of any size

39

-

-

... More
Supply & Fix switch piano single pole flush type 5A, 240 V one way.

300

-

-

... More
Supply & Fix Bell push flush type 5 amp, 230 Volts

20

-

-

... More
Supply & Fix switch socket combination 2 in 1 , 5 Amps multipurpose flush type.

90

-

-

... More
Supply & Fix switch socket combination 2 in 1, 3 pin, 5 and 15 Ampsflush type universal.

70

-

-

... More
Supply & Fix Ceiling rose surface bakelite three terminal, 240 V.

300

-

-

... More
S & F in repairs Ceiling fan regulator electronic stepped type, AC, 230 Volts, flush type.

50

-

-

... More
Supply and fix bell ding dong AC 230 V single pole.

20

-

-

... More
M & L for GI steel tubing medium grade 40mm dia and length up to 1.5 meter bent to shape of offset angle upto 45degree for fixing of security /street light fittings including MS clamps made of 32mm x5mm flat iron, nuts , bolts, etc all as directed by Engineer in charge

20

-

-

... More
Taking down carefully and Re-fixing of the same ceiling fan 1200mm sweep including provision of cable from ceiling nose/ conductor to fan and spray painting of ceiling fan with two coats of synthetic enamel paint, after preparation of surfaces, complete all as specified and directed.

40

-

-

... More
Supply And Fix in repairs MCCB DB TPN 4 Way double door 125 Amps prewired suitable for Triple Pole 125 A MCCB as incomer with the following acessories, a) MCCB TP 125 A 25 KA 415 Volt - 1 Nos b) Bus bar, Din rail , Neutral link Make -Havells/Indoasaian/Legrand/ABB/Schnider

2

-

-

... More
Supply And Fix in repairs MCCB DB TPN 8 Way double door 125 Amps prewired suitable for Triple Pole 125 A MCCB as incomer with the following acessories & connecting of existing cables & providing of acbel glands, a) MCCB TP 125 A 25 KA 415 Volt - 1 Nos b) Bus bar, Din rail , Neutral link Make - Havells/Indoasaian/Legrand/ABB/Schnider

2

-

-

... More
Supply & Fix MCB DB SPN 2 way 240 volts Single door, including connecting up with existing cable with new lugs The DB Shall be of Make - Havells/Indoasaian/Legrand/ABB/Schnider

5

-

-

... More
Supply & Fix MCB DB Double Door SPN 4 way 240 volts including connecting up with existing cable with new lugs. The DB Shall be of Make - Havells/Indoasaian/Legrand/ABB/Schnider

5

-

-

... More
Supply & Fix MCB DB Double Door SPN 8 way 240 volts including connecting up with existing cable with new lugs. The DB Shall be of Make - Havells/Indoasaian/Legrand/ABB/Schnider

10

-

-

... More
Supply & Fix MCB DB Double Door SPN 12 way 240 volts including connecting up with existing cable with new lugs The DB Shall be of Make - Havells/Indoasaian/Legrand/ABB/Schnider

10

-

-

... More
Supply & Fix MCB DB TPN 4 way 415 V double door with busbar including connecting up with existing cable with new lugs The DB Shall be of Make - Havells/Indoasaian/Legrand/ABB/Schnider

5

-

-

... More
M&L for MCB SP, 240 volt, 5 to 32 Amps, 10 KA, C Curve, Make -Havells/Indoasaian/Legrand/ABB/Schnider

200

-

-

... More
M&L for MCB SPN, 240 volt, 6 to 63 Amps, 10 KA, C Curve, Make -Havells/Indoasaian/Legrand/ABB/Schnider

30

-

-

... More
M&L for MCB TPN, 240 volt, 40 to 100 Amps, 10 KA, C Curve, Make -Havells/Indoasaian/Legrand/ABB/Schnider

5

-

-

... More
S&F single pole and neutral enclosure with a two pin and earth and metal clad plug socket complete with one single pole MCB 20 Amp 240 Volts complete all as specified and directed. Make - indoasain/Legrand/Havells

5

-

-

... More
M&L for sub main wiring with two single core 6.0 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC casing caping with and including PVC insulated 6 Sqmm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed. (Make :- PRESFIT/ PRECISION - Casing caping), (Make :- FINOLEX/ KEI/ POLYCAB - PVC Copper wire) Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit.

150

-

-

... More
M&L for earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the earth plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification.

15

-

-

... More
S&F GI strip size 25 x 4 mm all as directed including welding brazing and taking down of old copper strips as required at site

40

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.