Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 Jan 2025
Closing Date19 Feb 2025
Tender Amount₹ 48,00,000
Costs
EMD
₹ 96,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_695298_1Tender No
8646 GE SOUTH PUNETender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Removal of excavated material [soil] to a distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point where directed complete all as specified and as directed.
66
-
-
... More
M&L for galvanized iron pipe of 50mm bore (light grade) laying in road / drain crossing for cable protection pipe including necessary fittings and fixtures complete all as specified and as directed
48
-
-
... More
M&L for galvanized iron pipe 50mm bore (light grade) fixed to pole/ wall /floor for cable protection pipe including clamp of MS flat of size 50x5mm and nut, bolt & washers of size 50x12mm for clamping of cable protection pipe on wall / pole wherever required complete all as specified and as directed
60
-
-
... More
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling / mass concrete, complete all as specified and directed.
0.75
-
-
... More
M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation of pole, stay etc including necessary form work etc complete all as specified and directed.
8.5
-
-
... More
M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in coping & pedestal of pole etc including necessary form work etc complete all as specified and directed.
2.2
-
-
... More
M&L for laying reinforced concrete pipes, class NP2 of dia 100 mm, 2 nos half round (for bottom and top) and before laying exacaved area shall be leveling complete all as specified and as directed.
2220
-
-
... More
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m deep below normal ground level connected to galvanised iron strip of 32 x 6mm earth lead by means of bolt, nuts, washers of galvanised steel earth strip protected by and including GI pipe 40 mm dia bore (light grade) and connected to main test point as directed and including concrete pit in PCC(1:3:6) type C-1 precast RCC (1.1.5.3) type A-1 cover slab 54 x 5 cm reinforced with 4mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8mm dia TMT bar embedded in precast cover slab funnel wire means 20mm bore Gl pipe (medium grade) for watering charcoal and salt in alternate layers, including necessary excavation and earth work in any type of soil etc complete all as shown on electrical plate No.3 of SSR part-I and as specified and directed.
12
-
-
... More
Supply installing, commissioning and testing of cubical type LT panel board, outdoor canopy type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof, front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 3.0 mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands including dismantling old existing unserviceable panel of any type complete all as specified and directed including with the following accessories:-
INCOMING
(a). MCCB 4 pole, 415 Volts, 200 Amps, 25 KA- 01 No.
OUTGOING
(a) MCCB 4 pole, 415 Volts, 100 Amps, 10KA- 03 Nos.
(b) MCCB 4 pole, 415 Volts, 63 Amps, 10 KA-01 No. (spare) (c) MCB SPN, 415 Volts, 32 Amps, -03 Nos.
(d) Digital Voltmeter 0-500 V with selector switch-01 No.
(e) Digital VAF meter for basic electric system monitoring-01 No.
(f). Indicator lamp (RYB) (set of three)-01 Set
1
-
-
... More
Supply installing, commissioning and testing of cubical type LT panel board, outdoor canopy type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof, front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 3.0 mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands including dismantling old existing unserviceable panel of any type complete all as specified and directed including with the following accessories:-
INCOMING
(a). MCCB 4 pole, 415 Volts, 250 Amps, 25 KA- 01 No.
OUTGOING
(a) MCCB 4 pole, 415 Volts, 125 Amps, 16KA- 01 No.
(b) MCCB 4 pole, 415 Volts, 100 Amps, 10 KA-02 Nos.
(c). MCCB 4 pole, 415 Volts, 100 Amps, 10 KA-01 Nos (Spare)
(d) MCB TPN, 415 Volts, 32 Amps, -01 No.
(e) Digital Voltmeter 0-500 V with selector switch-01 No.
(f) Digital VAF meter for basic electric system monitoring-01 No.
(g). Indicator lamp (RYB) (set of three)- 01 Set
1
-
-
... More
Supply and laying in replacement of LT cable, cross-sectional area 240 sqmm 3.5 core, XLPE insulated, armoured, heavy duty electric underground cables with aluminium conductor 1100 volts grade including providing lugs etc as required complete all as specified and directed
100
-
-
... More
All as per Sl. item No. 14 above but 185 sq mm 3.5 core complete all as specified and as directed.
150
-
-
... More
All as per Sl. item No. 14 above but 150 sq mm 3.5 core complete all as specified and as directed.
300
-
-
... More
All as per Sl. item No. 14 above but 120 sq mm 3.5 core complete all as specified and as directed.
450
-
-
... More
All as per Sl. item No. 14 above but 95 sq mm 3.5 core complete all as specified and as directed.
500
-
-
... More
All as per Sl. item No. 14 above but 70 sqmm 3.5 core complete all as specified and as directed.
300
-
-
... More
All as per Sl. item No. 14 above but 50 sqmm 3.5 core complete all as specified and as directed.
300
-
-
... More
All as per Sl. item No. 14 above but 35 sqmm 3.5 core complete all as specified and as directed.
300
-
-
... More
All as per Sl. item No. 14 above but 25 sqmm 3.5 core complete all as specified and as directed.
300
-
-
... More
All as per Sl. item No. 14 above but 16 sqmm 4 core complete all as specified and as directed.
300
-
-
... More
All as per Sl. item No. 14 above but 16 sqmm 2 core complete all as specified and as directed.
300
-
-
... More
All as per Sl. item No. 14 above but 10 sqmm 4 core complete all as specified and as directed.
200
-
-
... More
All as per Sl. item No. 14 above but 10 sqmm 2 core complete all as specified and as directed.
200
-
-
... More
S&F in repair TPN copper bus bar box outdoor type of 200 Amps capacity mounted on porcelain bridge insulator for one incoming cable and 4 outgoing cable, housing in sheet metal enclosure of MS sheet 3.0 mm thick CRCA sheet and angle iron 40x40x6 mm frame, painted with two coats including arrangement for cable gland for incoming and outgoing cables, locking arrangement, suitable foundation / platform for mounting the FPB with space for and including the following switch gears complete all as specified and directed:- (a) MCCB 100 Amps, FP, 10 KA (for incoming control)
8
-
-
... More
M&L for preparation of old painted surface above the planting depth and PCC coping of steel tubular LT pole of 09.00 metre length including MS clamps cable protection pipe bracket fitted with street light fittings etc by scraping with steel wire brush and applying two coats of aluminium paint to external surface of poles MS cross arms MS clamp, cable protection pipe etc to give even shade including Zebra colour of painting from 1.50m height from the top of coping/ bottom of pole as per site condition and numbering of poles complete all as specified and as directed by Engr-in -charge
Note: Zebra colour will be applied by synthetic enamel paint of black / yellow colour as approved in alternate layer of 30 cm height of each layer
100
-
-
... More
Supply and fix in repairs energy efficient LED street light fitting of 45 watt made out of pressure die cast aluminium housing with toughened glass and high power LEDs with secondary optics, efficacy 110/120 LPW, IP 66 protection aerodynamically designed for all weather conditions with efficient thermal management including 10 KV SPD etc complete all as specified directed by Engineer in Charge.
Make:- Crompton, Model No. RAPTOR NEO Cat No: TRP-409-45-57-SL-GL-NSG or equivalent model in Havells, Bajaj, Wipro or Halonix
39
-
-
... More
Supply and fix in repair energy efficient LED street light fitting of 60 watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs with secondary optics, efficacy 110/120 LPW, IP 66 protection aerodynamically designed for all weather conditions with efficient thermal management including 10 KV SPD complete all as directed by Engineer in Charge
Make:- Crompton, Model No. RAPTOR NEO Cat No: TRP-409-60-57-SL-GL-NSG or equivalent model in Havells, Bajaj, Wipro or Halonix
32
-
-
... More
S&F in repairs LT service cable 6 sqmm 2 core drawn in to PVC conduit, medium grade for landscape lighting/ garden lighting inside trench at max 10 cm depth or mounting on floor / wall complete all as specified and as directed.
400
-
-
... More
S&F in repairs integral compact wide beam LED flood light luminaries with die cast aluminium alloy housing with IP 66 protection, tampered protective toughened glass 5mm thick, thermal shock Impact resistant cover, epoxy black powder coated finish, high purity pre-anodised specular aluminium sheet reflector, with silver painted contacts suitable for 1x100 Watts LED and connection with two runs of 2.5 Sqmm multi-stranded copper flexible wire including taking down old unserviceable one and testing complete as specified and as directed by the Engineer-in-Charge.
Make:- Halonix, Model: HLFLD-ML.17-100-CW-R01or equivalent in Wipro / Crompton / Bajaj /Havells
20
-
-
... More
Supply and fix in repairs LED post top lantern of 45 Watts, IP 65 protection within built electronic driver and aluminum housing in pure polyester UV resistant powder coated black finish, top maintainable product with top opening die cast cover, anti corrosive stainless steel screws & silicon Gasket, HET PMMA diffuser conforming to IS 10322 Part 5 / Sec 1 1987, suitable for pole diameter up to 75 mm, cable entry through pole from bottom, 3 way 10 Amps GFP mains connector duly wired up to terminal block complete all as specified and as directed. Make Halonix Cat part No. HLPT-04-45-CW or equivalent cat part in Bajaj, Crompton, Havells or Wipro
10
-
-
... More
Supply and fix in repairs GI pipe bracket suitable for street light fittings made out of 32 mm dia Gl pipe light grade 1.50 m long bent to required angle / shape with and including necessary clamps, nuts, bolts, & washers of suitable size compete all as directed by Engineer-in-Charge
30
-
-
... More
S&F in repairs PVC weather proof loop-in loop-out box with 4 pole terminal block mounted on porcelain or bakelite and MCB, SP, 6 Amps for controlling including necessary clamps for mounting on pole etc complete all as specified and directed Make: Sintex Cat Part No-GSJB 2014 of techno commercially or equivalent make.
40
-
-
... More
Supply, Jointing and testing in repairs cable jointing kit for 1.1 KV grade cable suitable for outdoor termination heat shrink type joint with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25-50 Sqmm complete all as specified and directed.
10
-
-
... More
Supply, Jointing and testing in repairs cable jointing kit for 1.1 KV grade cable suitable for outdoor termination heat shrink type joint with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70-150 Sqmm complete all as specified and directed.
10
-
-
... More
Supply, Jointing and testing in repairs cable jointing kit for 1.1 KV grade cable suitable for outdoor straight through heat shrink type joint with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25-50 Sqmm complete all as specified and directed.
10
-
-
... More
Supply, Jointing and testing in repairs cable jointing kit for 1.1 KV grade cable suitable for outdoor straight through heat shrink type joint with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70-150 Sqmm complete all as specified and directed.
10
-
-
... More
M&L for preparation of old painted steel or iron surfaces of existing LT panel by scrapping with steel wire brush/scrapper emery paper etc and applying two coats of synthetic enamel smoke grey paint over a coat of red oxide primer (painting shall be done by spray machine) including writing of incoming and outgoing details etc. at prominent place /location of LT panel with black synthetic enamel thick paint in white back ground complete all as specified and directed
Note: Necessary shut down of power supply shall be obtained from Engr-in-Charge by the contractor before proceeding with the work also electric supply shall be restored as early as possible after completion of the painting work.
10
-
-
... More
M & L for repair to LT panel door (inner and outdoor) by replacing the damaged hinges or welding the existing hinges, door locks, replacing the missing nuts, bolts & washers etc. tightening the cable glands, cable lugs, applying kuchha rubber strips onto the damaged insulation of cables, to prevent any short circuit/earth leakage, including cleaning the LT panel with compressed air complete all as directed by Engr-in-charge. Note: (i) The rate quoted shall be deemed to be inclusive of necessary spares required such as hinges, door locks, nuts, bolts, washers, kuchha rubbers etc.
(ii) Necessary shut down of power supply shall be obtained from Engr-in-Charge in writing by the contractor before proceeding with the work also electric supply shall be restored as early as possible after completion of above job work.
10
-
-
... More
M&L for repair to foundation of LT panel including the mounting angle iron frame foundation / angle iron frame by at least to an height of one feet and not more than three feet in directed order to by lifting the LT panel and increasing the height to avoid water ingressing in panel complete all as directed by Engr-in-charge.
Note: (i) The rate quoted shall be deemed to be inclusive of necessary excavation required to take out the cable loop, connecting and disconnecting the cables including with necessary PCC 1:2:4 type B-1 required for to increase the height of the foundation of panel or any welding work required to increase the height of the mounting legs of the angle iron frame. However if any straight through joint or end termination joint if any required will be measured and paid separately under respective items of BOQ
(ii) The contractor shall adhere to all safety measures required while lifting the LT Panel and any damage to man and material shall be at the risk of the contractor.
6
-
-
... More
S&F in repair volt meter, digital type, 0-500 volt with in-built selector switch including taking down existing old / unserviceable voltmeter from LT panel/ APFC Panel board carefully after disconnecting the electric connection complete all as specified and as directed
2
-
-
... More
S&F in repair Ampere meter, digital type, 0-500 Amps with in-built selector switch, complete with suitable size of CT's including taking down existing old/unserviceable Ammeter from LT panel / APFC Panel board carefully after disconnecting the electric connection complete all as specified and as directed.
2
-
-
... More
S&F in repairs indicator lamp, LED type of colour like red, blue and yellow including taking down existing old / unserviceable lamps from LT panel APFC Panel board carefully after disconnecting the electric connection complete all as specified and as dtrected.
6
-
-
... More
S&F in repairs MCCB, 415 volls, 400 Amp, breaking capacity 36 KA, 4 pole including taking down existing old / unserviceable MCCB from LT panel APFC Panel board carefully after disconnecting the electric connection complete all as specified and as directed
3
-
-
... More
S&F in repairs MCCB, 415 volls, 250 Amp, breaking capacity 25 KA, 4 pole including taking down existing old / unserviceable MCCB from LT panel APFC Panel board carefully after disconnecting the electric connection complete all as specified and as directed
4
-
-
... More
S&F in repairs MCCB, 415 volls, 200 Amp, breaking capacity 25 KA, 4 pole including taking down existing old / unserviceable MCCB from LT panel APFC Panel board carefully after disconnecting the electric connection complete all as specified and as directed
6
-
-
... More
S&F in repairs MCCB, 415 volls, 160 Amp, breaking capacity 16 KA, 4 pole including taking down existing old / unserviceable MCCB from LT panel APFC Panel board carefully after disconnecting the electric connection complete all as specified and as directed
6
-
-
... More
S&F in repairs MCCB, 415 volls, 125 Amp, breaking capacity 16 KA, 4 pole including taking down existing old / unserviceable MCCB from LT panel APFC Panel board carefully after disconnecting the electric connection complete all as specified and as directed
10
-
-
... More
S&F in repairs MCCB, 415 volls, 100 Amp, breaking capacity 10 KA, 4 pole including taking down existing old / unserviceable MCCB from LT panel APFC Panel board carefully after disconnecting the electric connection complete all as specified and as directed
12
-
-
... More
Supply & Fix in repairs off load change over switch 4 pole of capacity 200 Amps in sheet steel enclosure rated voltage 415 Volt, AC 50 Hz including connecting up the cables with suitable lugs complete all as specified and as directed Make:- INDOASIAN Cat part no OCFP0200 or equivalent cat part in L&T, Havells or C&S
2
-
-
... More
S&F in repairs 3/4 pole contactor for capacitor switching AC, 230/240 Volt, 50 HZs coil operated suitable for IEC rated 400 Volt 5-100 Amps max complete all as specified and directed
4
-
-
... More
S&F in repairs contactor 3/4 pole, ML-2.5 to 3.0 including taking down existing old unserviceable contactor from LT panel /APFC Panel board carefully after disconnecting the electric connection complete all as specified and as directed
4
-
-
... More
S&F in repairs contactor 3/4 pole, ML-4 including taking down existing old unserviceable contactor from LT panel /APFC Panel board carefully after disconnecting the electric connection complete all as specified and as directed
4
-
-
... More
Taking down of unserviceable capacitor from APFC panel and S&F new cylindrical capacitor heavy duty of capacity 1 KVAR complete all as specified and directed
Make- Legrand / Siemens / Schneider / L&T / C&S
4
-
-
... More
Taking down of unserviceable capacitor from APFC panel and S&F new cylindrical capacitor heavy duty of capacity 3 KVAR complete all as specified and directed
Make- Legrand / Siemens / Schneider / L&T / C&S
4
-
-
... More
Taking down of unserviceable capacitor from APFC panel and S&F new cylindrical capacitor heavy duty of capacity 5 KVAR complete all as specified and directed
Make- Legrand / Siemens / Schneider / L&T / C&S
4
-
-
... More
Taking down of unserviceable capacitor from APFC panel and S&F new cylindrical capacitor heavy duty of capacity 7.5 KVAR complete all as specified and directed
Make- Legrand / Siemens / Schneider / L&T / C&S
4
-
-
... More
Taking down of unserviceable capacitor from APFC panel and S&F new cylindrical capacitor heavy duty of capacity 10 KVAR complete all as specified and directed
Make- Legrand / Siemens / Schneider / L&T / C&S
4
-
-
... More
Taking down of unserviceable capacitor from APFC panel and S&F new cylindrical capacitor heavy duty of capacity 15 KVAR complete all as specified and directed
Make- Legrand / Siemens / Schneider / L&T / C&S
4
-
-
... More
Taking down of unserviceable capacitor from APFC panel and S&F new cylindrical capacitor heavy duty of capacity 20 KVAR complete all as specified and directed
Make- Legrand / Siemens / Schneider / L&T / C&S
4
-
-
... More
Taking down of unserviceable capacitor from APFC panel and S&F new cylindrical capacitor heavy duty of capacity 25 KVAR complete all as specified and directed
Make- Legrand / Siemens / Schneider / L&T / C&S
4
-
-
... More
Taking down the existing unserviceable automatic power factor control panel and supply and fix in repair Automatic power factor control panel microprocessor based including LED display input voltage 415 V AC,-15%, 50 HZs, three phase, delta connection with heavy duty cylindrical capacitor and 8 step control of capacity 10 KVAr complete all as specified and as directed Make:- Havells Cat Part No. QHKTCB5010X0 of equivalent cat part in ABB, Siemens, L&T, Schneider or C&S
1
-
-
... More
Taking down the existing unserviceable CT from the LT panel/ APFC panel and supply and fix new LT CT ring type suitable for primary current ratio 100/5 Amps, burden 5 VA, class 1.0 complete all as specified and directed. Make:- Havells Cat Part No:QSCELFBOL001 or equivalent cat part in ABB, Siemens, L&T, Schneider or C&S
3
-
-
... More
Taking down the unserviceable dimmer from the servo voltage stabilizer of 75 KVA/100 KVA capacity and supply and fix new dimmer suitable for variable transformer of servo voltage stabilizer of 75 KVA/100 KVA capacity complete all as specified and directed.
3
-
-
... More
Taking down the unserviceable carbon brush from the servo voltage stabilizer of 75 KVA/100 KVA capacity and supply and fix new carbon brush suitable for servo voltage stabilizer of 75 KVA/100 KVA capacity complete all as specified and directed.
3
-
-
... More
Taking down of old unserviceable buck boost transformer from the servo voltage stabilizer of 75 KVA/ 100 KVA capacity and supply and fix new buck boost transformer suitable for servo voltage stabilizer of 75 KVA /100 KVA capacity including necessary wiring complete all as directed by Engr-in-charge.
3
-
-
... More
Material and labour for servicing of servo voltage stabilizer of 75 KVA/ 100 KVA capacity with and including replacement of necessary wiring and copper lugs, contactors, relays etc. complete all as specified and as directed
Note: Rate quoted shall be deemed to be inclusive of necessary wiring and copper lugs required to be replaced however contactors and relays if required to be replaced will be measured and paid separately
2
-
-
... More
M&L for earthing complete with galvanised steel earth plate electrode including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.50 m below normal ground level connected to with and including earth lead of 4 mm dia GI wire up to 7.50m by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR Part-I(2009) connected to main switch board or main control board all as specified and testing on completion with & including provision of earth wire protected by galvanised iron 15 mm dia. light grade pipe up 7.50m and watering pipe shall be 20 mm bore medium grade with and including concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab in RCC (1:2:4) type B-1 using 20 mm graded stone aggregate duly reinforced with 8 mm TMT bars @100mm C/C on both sides with suitable cast iron lifting handle, GI earthing wire shall be encased in and including 15mm nominal bore GI 'light grade' tubing with all fittings from earth plate up to panel shall be provided & charcoal / salt funnel & other fittings etc. complete all as specified and as directed.
4
-
-
... More
Excavation in post holes (or similar holes) each not exc. 0.5 cum getting out including returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard/dense soil, complete all as specified and as directed.
10
-
-
... More
Supply, fixing and errecting in true vertical position of steel tubular swaged pole swan neck type single arm 9 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31, including painting with anti corrosive black bituminous paint internally complete and externally up to planting depth and exposed portion with Aluminium paint two coats over a coat of red oxide primer including taking down of old unserviceable / damaged pole complete all as specified and directed by Engr-in-charge.
(Note : Excavation and earth work, PCC for foundation and coping shall be measured and paid seperately under respective item of BOQ)
10
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%