Military Engineer Services Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Building Construction
Eprocure
Opening Date13 Dec 2024
Closing Date1 Feb 2025
Tender Amount₹ 17,75,00,000 
Notes
Download

Costs

Summary

Engineering, Procurement And Construction (epc) Of Def Single Accn (g Plus 6 Floors) For Sailors Otm Accn And Unit Shops

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
SCHEDULE "A" PART-III (ROAD, PATH, HARD STANDING, CULVERTS & SIGN BOARD) Total of Sch-'A' Part-III B/F

1

5899843

-

... More
SCHEDULE "A" PART-IV (SEWAGE DISPOSAL) Total of Sch-'A' Part-IV B/F

1

328097

-

... More
SCHEDULE "A" PART-V (AREA DRAINAGE) Total of Sch-'A' Part-V B/F

1

1475397

-

... More
SCHEDULE "A" PART-VI (EXTERNAL ELECTRIFICATION) Total of Sch-'A' Part-VI B/F

1

1000294

-

... More
SCHEDULE "A" PART-VII (EXTERNAL WATER SUPPLY) Total of Sch-'A' Part-VII B/F

1

109115

-

... More
SCHEDULE "A" PART-VIII (LIFT) Total of Sch-'A' Part-VIII B/F

1

9005

-

... More
SCHEDULE "A" PART-IX (RETAINING WALL, GATE AND CHAIN LINK FENCING) Total of Sch-'A' Part-IX B/F

1

12747621

-

... More
SCHEDULE "A" PART-X (ENVIRONMENTAL POND) Total of Sch-'A' Part-X B/F

1

489437

-

... More
SCHEDULE "A" PART-XI (SIGN BOARD) Total of Sch-'A' Part-XI B/F

1

10600

-

... More
SCHEDULE "A" PART-XII MISCELLANEOUS ITEMS

-

-

-

... More
Removing excavated material (any type) and depositing it outside Ministry of Defence Land. Notes: (i) Before quoting the tender, the bidders are advised to ascertain the distance outside MD and, at which the excavated material/ debris are to be disposed off. No extra claim what-so-ever shall be entertained on this account. (ii) This item shall be considered as per the requirement at site. (iii) All excavation earthwork covered under Sch'A' part II to part IX shall be measured and paid under this item.

2543

-

-

-

-

-

... More
Design, supply, installation, testing & commissioning of 16 passenger lift, having 1.5 m/s car speed, single speed motor suitable for 3- Ph, 415 V, 50 Hz electric power supply, conforming to IS-14665, suitable to serve G + 6 upper floors with AC variable voltage & variable frequency drive (VVVF drive), complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infrared sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, machine room & near ground floor landing door) complete all as specified and directed.

1

-

-

... More
The lift shall conform to the following technical specification. [i] Type of Lift: 16 Passenger [ii] Load Capacity: 1088 kg [iii] Speed: 1.5 m/s with single speed motor [iv] Power Supply: 3- Phase, 4 Wire, 415 V, 50 Hz AC [v] Type of Drive: AC Variable Voltage & Variable Frequency [vi] Type of Machine: Gearless [vii] Car Size: Not less than 2.56 m² [vii] Car and Landing Door at all floors: Automatic center opening with VVVF door drive, opening size not less than 1000 mm X 2000 mm, sliding type, fabricated by stainless steel sheet not less than 16 gauge having hairline finish (N-304) [viii] Car Enclosure: Manufactured with stainless steel frame not less than 16 gauge with hairline finish (N-304) having stainless false ceiling with hairline finish, internal lighting arrangement with LED light fittings operated on commercial supply and one LED light fitting operated on battery with invertor as emergency light complete internal ventilation system provided with concealed arial/cross flow fan with auto cut-off system and stainless steel grill/wire mesh for protection.

-

-

-

... More
[ix] Provision of standard thickness stainless steel hand-rail 40 mm diameter all around inside the car cabin [x] Terminal Buffers: Metal special spring/PU/Oil buffers as per manufacturer specifications. The buffing stroke should not be less than 200 mm. [xi] Door Opening (Inside): Protected by centre opening stainless steel doors with hairline finish doors with clear opening of 1000 mm X 2000 mm [xii] Car & Counter Weight Guide: Guide rails of MS 'T' section as per OEM design; counter weight shall be as recommended by OEM [xiii] Flooring: 5 mm thick Aluminium chequred plate / as per OEM design [ixv] Signals: [a] Combined luminous hall buttons with LED/LCD/VFD hall position indicators at all floors [b] LED/LCD/VFD for car position indicator of stainless steel [c] One No. of car opening panel with luminous buttons in car (stainless steel) [d] Car direction indicator in car & landing [e] Battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery (This system should be separate from ARD batteries.) [f] Overload warning feature in car cabin (display and announcing type both) [g] One fireman's switch to be installed at ground floor near landing door.

-

-

-

... More
[h] All signal fixture & car operating panel on hairline stainless steel face plate with hairline finish. [i] Infra red door sensor safety edge of door for entire height. [j] Built in announcing system without handset 2 Nos., one for lift car & ground floor landing door and one announcing system with handset in machine room. [k] The interior of the car should be provided with a device that audibly announce the floor position of lift car has reached and announce that car entrance/exit door is open or closed.   [xv] Stops & Opening:7-7 All opening on same side. [xvi] Safety Device: [a] Automatic rescue device (ARD)/automatic landing device operating with maintenance-free batteries having suitable capacity. The batteries must have auto charging facilities. The charger input be connected with converter of regenerative drive. [b] The ARD actuation time should be less than one second after failure of power supply and when ARD is operative the car should stop at the nearest floor and then open. [xvii] Operation: Simplex, full collective automatic operation with and without attendant. [xviii] Machine room: Located above the hoist way. Details as per building drawing [ixx] Hoist way construction details as per building drawing [xx] Civil work: Necessary Civil work viz. making good disturbed surfaces, modification to landing space to suit to car size, necessary foundation to machine etc. [xxi] One number of wall mounted type telephone instrument of make installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. The telephone instrument shall be connected in the telephone DB installed in the machine room. [xxii] Mirror of suitable size to be provided on the wall opposite to main door above SS railing. [xxiii] Provision of suitable size of copper conductor XLPE insulated cable from Main panel (Essential) installed at Ground floor to machine room will deemed to be included the rate quoted by the contractor

-

-

-

... More
Design, supply, installation, testing & commissioning of 8 passenger lift, having 1.5 m/s car speed, single speed motor suitable for 3- Ph, 415 V, 50 Hz electric power supply, conforming to IS-14665, suitable to serve G + 6 upper floors with AC variable voltage & variable frequency drive (VVVF drive), complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, telescopic opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infrared sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, machine room & near ground floor landing door) complete all as specified and directed.

1

-

-

... More
The lift shall conform to the following technical specification. [i] Type of Lift: 8 Passenger [ii] Load Capacity: 544 kg [iii] Speed: 1.5 m/s with single speed motor [iv] Power Supply: 3- Phase, 4 Wire, 415 V, 50 Hz AC [v] Type of Drive: AC Variable Voltage & Variable Frequency [vi] Type of Machine: Gearless [vii] Car Size: Not less than 1.43 m² [vii] Car and Landing Door at all floors: Automatic telescopic opening with VVVF door drive, opening size not less than 800 mm X 2000 mm, sliding type, fabricated by stainless steel sheet not less than 16 gauge having hairline finish (N-304) [viii] Car Enclosure: Manufactured with stainless steel frame not less than 16 gauge with hairline finish (N-304) having stainless false ceiling with hairline finish, internal lighting arrangement with LED light fittings operated on commercial supply and one LED light fitting operated on battery with inverter as emergency light complete internal ventilation system provided with concealed arial/cross flow fan with auto cut-off system and stainless steel grill/wire mesh for protection.

-

-

-

... More
[ix] Provision of standard thickness stainless steel hand-rail 40 mm diameter all around inside the car cabin [x] Terminal Buffers: Metal special spring/PU/Oil buffers as per manufacturer specifications. The buffing stroke should not be less than 200 mm. [xi] Door Opening (Inside): Protected by centre opening stainless steel doors with hairline finish doors with clear opening of 800 mm X 2000 mm [xii] Car & Counter Weight Guide: Guide rails of MS 'T' section as per OEM design; counter weight shall be as recommended by OEM [xiii] Flooring: 5 mm thick Aluminium chequred plate / as per OEM design [ixv] Signals: [a] Combined luminous hall buttons with LED/LCD/VFD hall position indicators at all floors [b] LED/LCD/VFD for car position indicator of stainless steel [c] One No. of car opening panel with luminous buttons in car (stainless steel) [d] Car direction indicator in car & landing [e] Battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery (This system should be separate from ARD batteries.) [f] Overload warning feature in car cabin (display and announcing type both) [g] One fireman's switch to be installed at ground floor near landing door

-

-

-

... More
[h] All signal fixture & car operating panel on hairline stainless steel face plate with hairline finish. [i] Infra red door sensor safety edge of door for entire height. [j] Built in announcing system without handset 2 Nos., one for lift car & ground floor landing door and one announcing system with handset in machine room. [k] The interior of the car should be provided with a device that audibly announce the floor position of lift car has reached and announce that car entrance/exit door is open or closed.   [xv] Stops & Opening:7-7 All opening on same side. [xvi] Safety Device: [a] Automatic rescue device (ARD)/automatic landing device operating with maintenance-free batteries having suitable capacity. The batteries must have auto charging facilities. The charger input be connected with converter of regenerative drive. [b] The ARD actuation time should be less than one second after failure of power supply and when ARD is operative the car should stop at the nearest floor and then open. [xvii] Operation: Simplex, full collective automatic operation with and without attendant. [xviii] Machine room: Located above the hoist way. Details as per building drawing [ixx] Hoist way construction details as per building drawing [xx] Civil work: Necessary Civil work viz. making good disturbed surfaces, modification to landing space to suit to car size, necessary foundation to machine etc. [xxi] One number of wall mounted type telephone instrument of make installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. The telephone instrument shall be connected in the telephone DB installed in the machine room. [xxii] Mirror of suitable size to be provided on the wall opposite to main door above SS railing. [xxiii] Provision of suitable size of copper conductor XLPE insulated cable from Main panel (Essential) installed at Ground floor to machine room will deemed to be included the rate quoted by the contractor

-

-

-

... More
M&L earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth strip 32x6mm by means of bolts, nuts, and washers of galvanized iron or steel all as shown in electrical plate No. 5 of SSR Part-I connected to main DB including PCC earth pit with CI cover, GI funnel with wire mesh, GI protection pipe for earth lead and for watering, excavation and earthwork in any type of soil & strata, filling the pit with charcoal and common salt surrounding the earth plate and earth strip upto 7.5m complete all as specified and as directed including testing on completion . (Lift = 4, DG Set = 4, External Water Supply = 2, External Electric Supply = 10)

20

-

-

... More
STANDBY POWER SUPPLY

-

-

-

... More
Supplying, installing, testing and commissioning of factory assembled Diesel Engine driven generating set, CPCB-IV emission complaint, PRIME RATED POWER(PRP) in accordance with ISO 8528, coupled with alternator AC, 75 kVA or nearest size on higher side at a power factor of 0.8 lagging, 415volts, AC, 3 phase, 4 wire, 50HZ, 1500RPM, directly coupled with diesel engine water cooled, mounted on common base frame complete with in built fuel tank of capacity 150 ltrs or nearest with fuel line & accessories, PCC foundation work as per manufacturer's instructions, AVM pads, micro processed based relay panel for automatic starting on mains failure, control panel showing all parameters of engine & alternator, sound proof canopy & other accessories etc all as specified and as directed by Engr-in-Charge. Additional specifications are as under :-

1

-

-

... More
Engine: It shall be liquid cooled, multi cylinder, in-line 4 stroke complete with centrifugal, gear driven water pump, electrical starting system, electronic injection, first fill of of lube oil and coolant, battery charging alternator, battery, flywheel etc. Alternator : It shall be brush-less type, screen protected, revolving field, self excited conforming to IS/IEC 60034-1 in IP23 enclosure with maximum voltage regulation +/-0.5%, solid state voltage regulator, Class of insulation H, flexible disc closed coupled etc

-

-

-

... More
Control Panel : It shall be powder coated for weatherproof and long lasting finish. It shall consists of micro processor based generator set monitoring, metering and control system with LCD display, Bus bars with suitable capacity with incoming/outgoing terminals, Indicating lamps, MCCB of suitable rating with short circuit protections etc Acoustic Enclosure : It shall meet stringent MoEF/CPCB norms. It shall be of CRCA sheet, 7/11 tank pretreatment process, fire retardant grade acoustic insulation material complying to IS 8183, external fuel filling provision with lock and key etc

-

-

-

... More
AMF Panel : It shall be outdoor type, factory made complete with AMF relay, Single phase preventer, MCCB TP and contactor of suitable rating, Mechanical interlocking for both commercial supply and DG supply, Digital multifunction meter, RYB indicators, selector switch Auto/Manual, cable entry at bottom with glands, interconnecting control wire between DG control panel and AMD panel etc

-

-

-

... More
Notes: (a) Any civil work reqd for installation of DG set & AMF panel at site shall be deemed to be including in the quoted rates (b) Contractor shall submit the detailed specification, particular model, make and literature alongwith drawing for approval of Garrison Engineer before placing order. (c) The factory inspection and testing shall be carried out in presence of MES testing officer. The pre-commissioning testing at site shall be carried out in presence of MES testing officer and the cost of the same shall be deemed to be included in unit rate quoted by contractor. (d) The Contractor has to arrange T&P and test load and fuel for testing 12hours as per CA provisions and cost for the same is deemed to be included in the quoted rate.

-

-

-

... More
EXTERNAL WATER SUPPLY

-

-

-

... More
M&L for Cutting in position existing water supply CI pipe line of 250mm or 300 mm dia and making out branch connection of 80 mm including all necessary CI fittings like end flange, CI Tee etc as per site condition including run lead joints, gaskets, nuts, bolts washers, excavation and earth work in any type of strata complete all as specified and as directed.

1

-

-

... More
Construction of brick masonary valve pit chamber 600x600x750mm (internal dimensions) with 150mm thick foundation using PCC 1:4:8 type D2 over 150mm thick hard core, 230mm thick brick wall built in cement and sand mortar 1:4, 15mm thick internal plaster including top of floor in extra cement, 3mm thick MS sheet cover with 50x50x6mm MS angle iron frame fixed in PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) and PCC coping 40mm thick with 25x6mm flat iron hold fast with handle made up of 25mm dia MS round bar and locking arrangement including necessary excavation in any type of strata, returning, refilling & removal of surplus soil to outside MD land all as shown on drawings complete all as specified and as directed.

2

-

-

... More
Supply, lay, test and commissioning DI pipe 80 mm bore, centrifugally spun as per IS: 8329-2000 suitable for push-on-joint with inside cement mortar lining, ISI marked with and including one rubber ring per pipe length and specials as required at site, class K-7 complete all as specified and as directed. Note : Excavation, RFR shall be measured and paid separately.

850

-

-

... More
Supply installation, testing and commissioning of monoblock centrifugal pumpset cast iron body 300 LPM at 40 mtrs with CI impeller, pump shaft carbon steel, gland packed sealing including S&F of pressure guage with one controlling ball valve and priming arrangement with GI pipe line, valve etc coupled with 3 phase induction motor suitable for operation on 400/415V, AC with coupling mounted on channel iron base frame including nuts, bolts & washers, with PCC foundation, nuts, bolts & washers as per manufacturer' instructions complete all as directed. Note: The quoted rate shall deemed to be included the cost of interconnecting copper cable between starter and pump set with suitable lugs, cable protection measures etc.

2

-

-

... More
Supply, Install, Test & Commissioning of factory made indoor LT Panel board (Pump House Panel) cubical type floor mounting, dust and vermin proof made out of 2 mm thick CRCA sheet steel with angle iron base frame, free standing on cable duct with cable entry holes at the bottom suitable for operation on 440 Volts, AC 3 phase, 4 wire, 50Hz with 200 Amps rated copper Bus Bar, fully compartmentalised, vermin proof, painting with powder coating 7 tank process suitable for IP-52 protection including suitable PCC foundation as per manufacturer recommendation complete and comprising of the following specifications are as under :-

1

-

-

... More
(a) 200 A rated copper bus bars with epoxy insulators - 01 Job (b) MCCB, 4 pole, 63 Amps, with ultimate breaking capacity of 16 KA at 415V, with thermal magnetic release, thermal overload setting - 01 No (Incomer). (c) MPCB 4 pole 32 Amps, 415V, 16 KA – 03 Nos (Out going) (d) FASD starter suitable for pumpset upto 7.5 HP complete with single phase preventor, timer, contactors, relays, push buttons, ON/OFF indicators etc - 02 Nos (e) MCB SPN 6-32A, 230 V- 2 Nos (Lighting DB) (f) Digital Voltmeter 0 to 500 Volts- 1 No. (g) Digital Ammeter 0 to 63 A with CTs- 1 No. (h) Phase indicating lamp LED type -set of three incoming. (j) Complete wiring of panel board with suitable size of PVC insulated copper conductor cables.

-

-

-

... More
S&F 80 mm foot valve, gun metal, ISI marked, screwed, integral seat type conforming to IS-4038 complete all as specified and as directed by Engr-in-Charge.

2

-

-

... More
S&F flanged CI air release valve double ball type, EPDM coated wooden balls suitable for 80 mm bore CI pipe as per IS-14845, ISI marked including all fittings, joints with rubber or fibre board, bolts and nuts, washers, etc. complete all as specified and as directed by Engr-in-Charge.

1

-

-

... More
EXTERNAL ELECTRIC SUPPLY

-

-

-

... More
Supply, laying, testing and commissioning HT XLPE insulated, screened,earth PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) of size 3 core 185 sqmm with aluminium conductor, suitable for 22KV grade as par relevant IS including latest amendment for IS (marked cable) testing commissioning along with complete laid in trenches duct etc all as specified and directed by Engr-In-Charge. Note : Excavation, RFR, Sand & Cable covers shall be measured and paid separately.

450

-

-

... More
Supply, installation, testing and commissioning of 22 KV, 630A out door RMU, motorised, both side extendable, single way SF6, with breaking capacity of 21 KA for 3 second with self powered non-directional IDMT (Inverse definite minimum time ) over current and earth fault relays (micro processor based), cable box with cable cover interlock for front termination of the cable suitable upto 2R X 3 core 185 sqmm (XLPE) for VCB feeder cable door should be as per IP 54 and manufacturer design and specification.

1

-

-

... More
Notes : (i) RMU shall be installed in extension of existing outdoor RMU and hence compatibility shall be ensured. (ii) The RMU enclosure (Outer) shall be made up of CRCA of 2 mm thickness or galvanised of 1.6 mm thickness. The rating of enclosure shall be suitable for operation on three phase, three wire, 22 kV, 50 cycles, A.C. System with short-time current rating of 21KA for 3 seconds. (iii) The complete RMU enclosure shall be of degree of protection IP 54 (Main Door close) and IP 41 (Main Door open). (iv) The inner tank shall be robotically welded stainless steel sheet of minimum 2mm thickness. The tank shall be sealed with A pressure relief arrangement (v) Contractor shall submit GA drawing, Foundation plan, internal wiring diagram, tripping schematic, BOM to the Garrison Engineer for approval before placing order (vi) The quoted rate deemed to be included the cost of PCC foundation, cable trench etc.

-

-

-

... More
Supply, install, testing and commissioning of Compact sub station (CSS) 22KV/415V, 160KVA, 50Hz, 3 Phase comprising following’s :-

1

-

-

... More
(a) HT Switchgear : Non-extensible One way RMU, 22KV, 630 Amps, manually operated VCB with self powered relay having over current and earth fault protection, internal arc tested for 21KA for 3 seconds all as per IEC 62271-202:2022. Interconnection between HT switch gear and transformer shall be using suitable or OEM recommended size alumnium or copper un-armoured XLPE cable. The incomer of HT switchgear should be suitable for termination of 1 run x 3C x 185 Sqmm 22KV aluminium armoured XLPE cable.

-

-

-

... More
(b) Transformer : 160KVA, 22KV/415V, Dyn, Air Natural cooling, Oil cooled Transformer with off circuit tap links +5% to 5% @ 2.5% on HT side all as per IS 1180 level 2 energy efficiency, impedence ___ , transformer compartment internal arc tested as per IEC 62271-202:2022 (c) MV Switchgear Panel : 415V indoor MV panel with 400 Amps Alumnium bus bars (100% for Phase & 50% for Neutral), complete with internal wiring consisting of (I) Incomer : MCCB 250A FP Thermally adjustable type 25KA – 01 No (ii) Outgoings : MCCB 160A TP thermally adjustable type 25KA – 01 No, MCCB 125A TP thermally adjustable type 25KA – 02 Nos, MCCB 100A TP thermally adjustable type 25KA – 02 Nos. Interconnection between Transformer and MV panel shall be using suitable size copper/alumnium bus bars / cables. Internal earthing connections by using 50 x 6mm GI strips including Transformer neutral. (d) Enclosure : It shall be Outdoor type having modular construction of Galvanised sheet steel. The enclosure exterior shall be painted with polyurethane paint / powder coated. Enclosure shall be provided with lock and key arrangement. The compartment illumination lamp with door operated switch shall be provided. Degree of Protection IP54 for HT and LT switch gear as per IEC 61330 & IEC 62271-202. The HT and LT cable entry shall be of Bottom entry of CSS enclosure. Necessary hole arrangements with glands to be provided.

-

-

-

... More
Notes : (i)The firm/OEM should be a manufacturer of VCB & Transformer and tested for internal arc. Pre-fabricated SS shall be type tested for internal arc, temperature rise test, Degree of protection IP 54 for HT and LT switch gear and IP 23 for transformer compartment as per IEC 61330 & IEC 62271-202 (ii) CSS shall be outdoor plinth mounted type. The foundation shall be as per the recommendations of OEM. The cost of foundation is deemed to be included in the quoted rate. (iii) Multifunction digital meters to indicate voltage, current, %THD and frequency to be provided (iv) All doors should be earthed with suitable braided copper. (v) The contractor shall submit GA drawings, electrical schematic diagrams, BOM, type test certificates, foundation drawing with plan and loading details to Garrison Engineer for approval before placing order. (vi) Contractor shall arrange for Pre-despatch inspection (PDI) at factory premises and Pre-commissioning testing on site at his own cost. The tests shall be carried out in presence of MES Testing officer.

-

-

-

... More
Supply, install, testing and commissioning of factory made vermin proof LT panel (Non Essential) Indoor cubical, self supported, CPRI Approved make, front and rear openable, double door hinged type with locking arrangement and slopping top canopy, suitable protection with dust and vermin proof etc, fabricated out of 2mm thick CRCA sheet duly powder coated with 7 tank chemical process, mounted fixed on and included MS angle section 50 x 50 x 6 mm on PCC 1:2:4 type B-1, platform 60 CM above the ground level and 45 CM below the ground level, factory fabricated with front and back openable double door system with and lock openable by keys, having chromium plated 19 mm dia fancy lock, louvers and air vent, gasket including following:

1

-

-

... More
a) Copper bus bar 250 Amps cap fixed on insulator not less than 1.0 mtr long bus bar -1 set Incomer MCCB 160 Amps, 4 pole, 415 Volts AC having rupturing capacity 25 KA - 01 Nos Outgoings (i) MCCB 4 pole, 40 Amps, 415 Volts, AC having rupturing capacity 25 KA - 8 Nos (To feed each floor main DB and 01 spare) (ii) MCCB 4 pole, 80 Amps, 415 Volts, AC having rupturing capacity 25 KA - 1 No (To feed laundry room main DB) (b) Digital Voltmeter 0 - 500 volt with selector switch -01 No (c) Indicator Lamp LED type(R-Y-B) with holder-01 set of three. (d) Digital Ammeter 0 – 160 A with CT Coils of suitable ratio - 01 Set (e) Internal wiring with suitable size of PVC insulated stranded copper conductor duly crimped with copper lugs ferruled.

-

-

-

... More
Notes : Contractor shall note that the scope of work beyond LT Panels (Non essential) shall be considered as internal electrification and the same shall be designed, planned & executed under the Internal electrification Annexure/Job.

-

-

-

... More
Supply, install, testing and commissioning of factory made vermin proof LT panel (Essential services) Indoor cubical, self supported, CPRI Approved make, front and rear openable, double door hinged type with locking arrangement and slopping top canopy, suitable protection with dust and vermin proof etc, fabricated out of 2mm thick CRCA sheet duly powder coated with 7 tank chemical process, mounted fixed on and included MS angle section 50 x 50 x 6 mm on PCC 1:2:4 type B-1, platform 60 CM above the ground level and 45 CM below the ground level, factory fabricated with front and back openable double door system with and lock openable by keys, having chromium plated 19 mm dia fancy lock, louvers and air vent, gasket including following:

1

-

-

... More
a) Copper bus bar 300 Amps cap 4 wire fixed on insulator not less than 1.0 mtr long bus bar -1 set Incomer MCCB 125 Amps, 4 pole, 415 Volts AC having rupturing capacity 25 KA - 01 Nos Outgoings (i) MCCB 4 pole, 40 Amps, 415 Volts, AC having rupturing capacity 25 KA – 07 Nos (To feed lift-02 Nos, Fire terrace pump-01 No, STP-01 No, Cooling appliance main DB-01 No, Pump House panel-01 No and 01 spare) (ii) MCB DP, 6-32 Amps, 230 Volts, AC having rupturing capacity 10 KA - 03 Nos (To feed street light timer-01 No and spare-02 Nos) (b) Digital Voltmeter 0 - 500 volt with selector switch -01 No (c) Indicator Lamp LED type(R-Y-B) with holder-01 set of three. (d) Digital Ammeter 0 – 160 A with CT Coils of suitable ratio - 01 Set (e) Digital timer and double contactor 32 Amps to control street lights automatically (f) Internal wiring with suitable size of PVC insulated stranded copper conductor duly crimped with copper lugs ferruled.

-

-

-

... More
Notes : Contractor shall note that the scope of work beyond LT Panel (Essential) shall be considered as internal electrification and the same shall be designed, planned & executed under the Annexures / Jobs of lifts, STP, fire fighting etc as applicable except LT cables upto Pump house LT Panel, STP Main panel & street lights.

-

-

-

... More
Supply, install, testing and commissioning of outdoor type APFC panel 75 KVAR (in stages 2, 3, 5, 5, 10, 10, 20, 20) rated voltage 415 Volts, 3 phase, 50Hz, Delta connection, MPP/super heavy duty cylindrical capacitors, capacitor duty contactors with suitable MCBs/MCCBs, intelligent power factor controller, with 7% aluminum wound reactor units tested in accordance with IS 16636/IEC 61558 with contactor switching. The Main incomer shall be MCCB 160A FP 25KA breaking capacity. Panel shall be provided with Auto-manual switch, LED RYB indicators, LED Capacitor/Step ON/OFF indicators, Digital VAF & PF meter, CT coils, interconnecting wires between main LT panel & APFC panel for analyzing PF all as specified and as directed by Engr-in-Charge.

1

-

-

... More
Notes: (i) Contractor shall submit GA drawing, electrical circuit diagram etc to the Garrison Engineer for approval before placing order. (ii) The contractor shall provide PCC foundation all as per OEM recommendation without any extra cost.

-

-

-

... More
Supply and fixing of outdoor weatherproof PVC enclosure junction box of size 250x200x100mm fitted to the pole fixing with MS FI clamps size 25mm wide x 2mm thick 02Nos, suitable size nuts, bolts and washers complete including 3 amps MCB SP and Bakelite connector for terminating incoming and out going cables complete all as specified & directed by Engineer-in-Charge

8

-

-

... More
Supply Installation , testing and commissioning of LED type street light fitting suitable for 35W capacity LED lamp, IP 66 pressure die cast housing with epoxy powder coated aluminium housing drak graphite gray colour finish Enclosure complete with control driver, fixed on street light pole supplied and connected with 1.5 sqmm 3 core copper cable from street light connector to pole junction box with suitable size lugs/thimble complete all as specified and directed by Engineer-in-Charge.

8

-

-

... More
Note: The quoted rate shall deemed to be included the cost of supply and fixing of 40mm bore GI pipe, ISI Marked, light grade 1.5m long bent to shape, fixed on pole with flat iron 32x3mm MS clamps 02Nos, including suitable size nuts, bolts and washers made of GI/steel complete.

-

-

-

... More
Supply, jointing, testing and commissioning cable jointing kit for 22 KV grade cable for indoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 120 to 185 sqmm complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
SIGN BOARD

-

-

-

... More
Supplying of Retro Reflective sign board made up with 1.2 mm thick stainless steel sheet, of which both faces shall be fully covered with high Intensity Prismatic (HIP) Retro Reflective sheeting of approved specification as per MORTH having approved message (Matter and Base) fully processed by pressure sensitive equipment of approved brand (Avery Dennison / 3M ) fixed on stainless steel frame made up of SS as described complete all as directed.

7.5

-

-

... More
Supply & Erection of framed work for Sign board using stainless steel Gde 304 tubular section (round/square) size 25 mm to 50 mm with all fittings like bend, tee etc. complete all as specified and directed by EIC. Note: The design of each sign board frame / stand shall be approved by Engineer-in-charge.

62.5

-

-

... More
ARBORICULTURE

-

-

-

... More
Preparing the ground surface by removing all vegetation, debries, stone etc and loosening / tiling the top layer of soil to a depth of 225 mm including digging out unsuitable soil and remove the same to a distance not exceeding 50m replace the removed quantity of soil with approved suitable soil obtained from out side MD land and preparing combination of soil and manure in the ration of 2:1 and application at site including spreading leveling so as to form a layer of 225mm average thickness complete all as spedified and directed at site. Note : Supply only additional quantity of approved soil and manure will be measured and paid separately.

350

-

-

... More
Supply only suitable soil for lawn/bed/hedge etc as specified and directed

102

-

-

... More
M& L for brick edging along ourter faces of mehendi hedge and flower bed complete all as specified and directed

120

-

-

... More
Supply only manure ( Cow dung) for bed/lawn/hedge etc all as specified and directed

20

-

-

... More
Development of the area by planting of mexicon grass with dibbling method by keeping the spacing of 30 centimeter between the tufts of grass including trenching the ground, watering rolling, moving (if required) and de-weeding complete all as specified and directed till the grass form a thick carpet free from weeds including the cost of labour, tools and tackles complete.

350

-

-

... More
Supply and plantation of flowering bed with minimum 30cm spacing between the plants (with tantena plant) includig preparation of flower beds by doing all horticultural activities like trenching , watering , de-weeding etc, including the cost of labours, tools and tackles complete for a period till flower plants become live properly and flower bed takes proper form complete in all respect all as specified.

150

-

-

... More
Supply and plantation of flowering bed with minimum 30cm spacing between the plants (with tantena plant) includig preparation of flower beds by doing all horticultural activities like trenching , watering , de-weeding etc, including the cost of labours, tools and tackles complete for flowering hence with minimum 3 plants per sqm feet ( feet tantena plant) 30cm wide along the inner face of mehendi hedging .

90

-

-

... More
Development and plantation of hedge (with mehendi plant) 30cm wide and 30cm high in two rows minimum 12 sticks per meter in a row including preparation of hedge beds by doing all horticultural activities, like trenching, watering, de-weeding etc, including the cost labours, tools and tackles complete for a period till hedges plants become live properly and hedge take proper form complete all as specified and directed.

90

-

-

... More
Manning operation for maintenance of grass and flower beds for 6 months periods 6 Months = 6 x 30 = 180 days

180

-

-

... More
Supply and planting of below mentioned trees in 0.25-0.30 m poly bags with height 0.90-1.20 m including holes 1.20 m dia x 1.20 m deep in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the atio 2:1 (2 parts of stacked volume of earth reduction of 20 % with 1 part of stacked volume of sludge or manure after reduction by 8 % , flooding with water and removal of soil:

-

-

-

... More
FRUIT PLANTS

-

-

-

... More
Kinnow

30

-

-

30

-

-

20

-

-

... More
SHADDY/ ORNAMENTAL PLANTS

-

-

-

... More
casoraina

10

-

-

15

-

-

... More
Amaltas

30

-

-

40

-

-

... More
Gulmohar

20

-

-

20

-

-

30

-

-

... More
Seesham

10

-

-

20

-

-

... More
Supply and planting of hedge shrubbery as directed by Engineer- in-charge including creation of beds by excavating 60 cm deep and 60 cm wide trenching the excavated base to a further depth of 30 cm re-filling the excavated earth after breaking clods and mixing with sludge or manure in the ratio 1:8 (8 parts of stacked volume of earth after reducing 20% with 1 part of stacked volume of sludge or manure after reduction by 8 %, flooding with water ,filling with earth if necessary, watering and finally fine dressing ,levelling etc. including stacking and disposal of material declared unserviciable and surplus earth by spreading and levelling as directed within a lead of 50 m and lift upto 1.0 m complete.

830

-

-

... More
Maintenance of plants / hedges/ grass by weeding hosing, saucer making once in every month for plants/ hedge, once in every 15 days for carpet gass/ country grass /doob grass, burmuda grass; prunning dried branches once in every week, depositing the material at place as directed by Engineer-in-charge and planting the new plants in place of dead plants of same species and height tuning with dods wherever required by replacing the dead patches of grass with the same grass as required without extra cost to the deptt and as directed complete for all above works

6

-

-

... More
FURNITURE

-

-

-

... More
Supply only Almirah medium steel, as per drawing No. FD-1032, complete all as specified and directed.

40

-

-

... More
Supply only Chair Easy, as per drawing No. FD-229 complete all as specified and directed.

43

-

-

... More
Supply only Chair Writing, as per drawing No. FD/E6/MAP/12, complete all as specified and directed.

59

-

-

... More
Supply only Peg Set of Three, as per drawing No. FD-253, complete all as specified and directed.

40

-

-

... More
Supply only Table Writing, as per drawing No.FD-275, complete all as specified and directed.

27

-

-

... More
Supply only Mirror Dressing (Gents), as per drawing No. FD/E6/MAP/16, complete all as specified and directed.

39

-

-

... More
Supply only Charpoy IP hard Top, as per drawing No. FD/MAP-II/01 complete all as specified and directed.

61

-

-

... More
Supply only Locker bed side steel, as per drawing No. FD-1029, complete all as specified and directed.

27

-

-

... More
Supply only Chair Wooden Bottom, as per drawing No. FD-285, complete all as specified and directed.

8

-

-

... More
Supply only Table 600x600x760, as per drawing No. FD-293. complete all as specified and directed.

5

-

-

... More
Supply only Board Notice with Glass door 2400x1220mm, as per drawing No. FD-99(R) complete all as specified and directed.

2

-

-

... More
Supply of Chair Dinning, as per drawing No. FD/MAP-II/05, complete all as specified and directed.

36

-

-

... More
Supply only Table Dinnng 6 Person, as per drawing No. FD/MAP-II/03, complete all as specified and directed.

6

-

-

... More
Supply only Receptacle PVC, as per drawing No. FD/E6/MAP/13, complete all as specified and directed.

3

-

-

... More
Supply only Stool Wooden, as per drawing No. FD/E6/MAP/14, complete all as specified and directed.

2

-

-

... More
Supply only Table Cook House, as per drawing No. FD-1019, complete all as specified and directed.

1

-

-

... More
Supply only Safe Meat & Milk, as per drawing No. FD-47(M), complete all as specified and directed.

2

-

-

... More
Supply only Hot Case Large, as per drawing No.FD-364, complete all as specified and directed.

1

-

-

... More
Supply only Form without back, as per drawing No.FD-1027 complete all as specified and directed.

1

-

-

... More
Supply only Table peg, as per drawing No. FD-384, complete all as specified and directed.

13

-

-

... More
Supply only Sofa Set three persons, as per drawing No. FD/MAP-II/02, complete all as specified and directed.

2

-

-

... More
Supply only Table Centre, as per drawing No. FD-375, complete all as specified and directed.

4

-

-

... More
MANNING & OPERATION OF LIFTS FOR 60 MONTHS POST COMPLETION OF WORK (REFER ANNEXURE-XVI)

-

-

-

... More
Manning & Operation of fully automatic electrically operated passenger lift of provided make, type and 08 passengers lifts - 01 No. and 13 passengers lifts - 01 No. , covering all floors, speed 1.5m/sec, SS lift installed in the subject project as per tender by 01 x lift operator in 2Shifts and 01 operator in night shift on all days including Sundays and holidays (1st Shift-0600 hrs to 1400 hrs and 2nd Shift-1400 hrs to 2200 hrs and night shift-2200 hrs to 0600 hrs) including taking care of all lifts from any pilferage or damage etc. ,Period of manning & operation shall be 60 months from the date of completion of the project. (TOTAL number of lift operators required per day are 03 nos.) (Total 02 Nos lifts) and 1 x lift operator at night including Sundays & holidays during the defects liability period of the project and after for 03 years after the defects liability period of the project, complete all as mentioned below and all as specified and directed:-

-

-

-

... More
11 months after completion of work

11

-

-

... More
11 months after completion of BoQ Sl. item No. 77.02 here-in-before

11

-

-

... More
11 months after completion of BoQ Sl. item No. 77.03 here-in-before

11

-

-

... More
11 months after completion of BoQ Sl. item No. 77.04 here-in-before

11

-

-

... More
11 months after completion of BoQ Sl. item No. 77.05 here-in-before

11

-

-

... More
05 months after completion of BoQ Sl. item No. 77.06 here-in-before

5

-

-

... More
MANNING & OPERATION OF E & M INSTALLATIONS FOR 60 MONTHS POST COMPLETION OF WORK (REFER ANNEXURE-XV)

-

-

-

... More
Manning & Operation of E/M installation consisting of Fire fighting installations, electrically operated pump sets (for fresh water and for treated grey water) of different capacities including DG set installed in the subject project as per tender by placing one FGM and one valve man in each shift and maintenance of log book, taking care of pumps / valves / overflow of tanks, other minor repairs and leakages daily in three shifts from 0600 hrs to 1400 hrs, 1400 hrs to 2200 hrs and 2200 hrs to 0600 hrs including cleaning, daily maintenance, testing onsite water parameters using pH tester, chloroscope, TDS meter etc.Period of manning & operation shall be 60 months from the date of completion of the project. (TOTAL number of FGM required per day are 03 nos.) on all days including Sundays and Gazetted holidays during the defects liability period of the project and for 03 years after the defects liability period of the project, complete all as mentioned below and all as specified and directed:-

-

-

-

... More
11 months after completion of work

11

-

-

... More
11 months after completion of BoQ Sl. item No. 78.02 here-in-before

11

-

-

... More
11 months after completion of BoQ Sl. item No. 78.03 here-in-before

11

-

-

... More
11 months after completion of BoQ Sl. item No. 78.04 here-in-before

11

-

-

... More
11 months after completion of BoQ Sl. item No. 78.05 here-in-before

11

-

-

... More
05 months after completion of BoQ Sl. item No. 78.06 here-in-before

5

-

-

... More
ANNUAL COMPREHENSIVE MAINTENANCE OF LIFTS FOR 36 MONTHS POST DLP PERIOD (REFER ANNEXURE-XVII)

-

-

-

... More
Comprehensive maintenance as per OEM manual and repairs of fully automatic electrically operated passenger lift of provided make and 08 Passengers and 13 Passengers, covering all floors, speed 1.5m/sec, SS lift installed in the subject project as per tender for lifts (Total 02 Passengers Lifts), comprising of all devices and accessories through out 36 months on all days including holidays for period of 03 years after expiry of defects liability period, complete all as mentioned below and all as specified and directed.

-

-

-

... More
One year after expiry of defects liability period

12

-

-

... More
One year after completion of BoQ Sl. item No. 79.02 here-in-before

12

-

-

... More
One year after completion of BoQ Sl. item No. 79.03 here-in-before

12

-

-

... More
ANNUAL COMPREHENSIVE MAINTENANCE OF WATER SUPPLY INSTALLATIONS, RO PLANT FOR 36 MONTHS POST DLP PERIOD (REFER ANNEXURE-XVIII)

-

-

-

... More
Comprehensive annual maintenance including all repairs / replacement and preventive maintenance / servicing of Complete water supply installations, & RO Plant all as provided & installed under the subject work throughout for a period of 03 (Three) years including Sundays and holidays after expiry of defects liability period (DLP). Contractor is responsible for efficient running of pump sets, RO plant etc. Preventive maintenance or periodical servicing, periodical painting, filtration shall be carried out all as per OEM manual or recommendation or as directed by Engr-in-Charge. Qualified service engineer/technician shall carryout periodical servicing all as per OEM schedule or manual and shall ensure efficient running always complete all as mentioned below and all as specified and directed.

-

-

-

... More
One year after expiry of defects liability period

12

-

-

... More
One year after completion of BoQ Sl. item No. 80.02 here-in-before

12

-

-

... More
One year after completion of BoQ Sl. item No. 80.03 here-in-before

12

-

-

... More
ANNUAL COMPREHENSIVE MAINTENANCE OF MECHANICAL LAUNDRY FOR 36 MONTHS POST DLP PERIOD (REFER ANNEXURE-XIX)

-

-

-

... More
Annual Comprehensive maintenance including all repairs / replacement and preventive maintenance / servicing of Mechanical laundry all as provided under this contract throughout for a period of 03 (Three) years including Sundays and holidays after expiry of defects liability period (DLP) complete all as mentioned below and all as specified and directed.

-

-

-

... More
One year after expiry of defects liability period

12

-

-

... More
One year after completion of BoQ Sl. item No. 81.02 here-in-before

12

-

-

... More
One year after completion of BoQ Sl. item No. 81.03 here-in-before

12

-

-

... More
ANNUAL COMPREHENSIVE MAINTENANCE OF PACKAGE TYPE STP PLANT FOR 36 MONTHS POST DLP PERIOD (REFER ANNEXURE-XX)

-

-

-

... More
Comprehensive annual maintenance as per OEM manual and repair / replacement of defective parts of STP Plant installed under the subject contract as per schedules and supply of media, sodium hypochlorite, jaggery, Urea, blower oil, periodical painting etc all as required for efficient treatment of sewage throughout for a period of 03 (Three) years including Sundays and holidays after expiry of defects liability period (DLP). Qualified service engineer shall carryout periodical servicing all as per OEM schedule or manual and shall ensure efficient running always complete all as mentioned below and all as specified and directed.

-

-

-

... More
One year after expiry of defects liability period

12

-

-

... More
One year after completion of BoQ Sl. item No. 82.02 here-in-before

12

-

-

... More
One year after completion of BoQ Sl. item No. 82.03 here-in-before

12

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.