Military Engineer Services Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date5 Sep 2024
Closing Date4 Oct 2024
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S & F in replacement Sensing Control Card, 240 Volts, 50 Hz, AC, suitable /compatible to existing Servo Voltage Stabilizer, Oil Cooled type, of capacity 25 to 75 KVA complete all as specified and directed. Make of Stabilizer : M Guard/Electra

4

-

-

... More
All as per item No. 4 above but capacity 100 to 200 KVA. Make of Stabilizer : M Guard/Vinitec/Volina

3

-

-

... More
All as per item No. 4 above but capacity 500 KVA. Make of Stabilizer : Vinitec/Volina

2

-

-

... More
S & F in replacement Servo Motor, 1-ph, 240 Volts, 50 Hz, AC, suitable /compatible to existing Servo Voltage Stabilizer, Oil Cooled type, of capacity 25 to 75 KVA complete all as specified and directed. Make of Stabilizer : M Guard/Electra

3

-

-

... More
All as per item No. 7 above but capacity 100 to 200 KVA. Make of Stabilizer : M Guard/Vinitec/Volina

2

-

-

... More
All as per item No. 7 above but capacity 500 KVA. Make of Stabilizer : Vinitec/volina

1

-

-

... More
S & F in replacement Selector Switch, stepwise selection, 10 Amps, 240 Volts, 50 Hz, AC, suitable /compatible to existing Servo Voltage Stabilizer, Oil Cooled type, of capacity 25 to 75 KVA. Make of Stabilizer : M Guard/Electra

2

-

-

... More
All as per item No. 10 above but capacity 100 to 200 KVA. Make of Stabilizer : M Guard/Vinitec/Volina

2

-

-

... More
S & F in replacement Volt Meter, analog type, range from 0 to 260 Volts, suitable /compatible to existing Servo Voltage Stabilizer, Oil Cooled type, of capacity 25 to 75 KVA. Make of Stabilizer : M Guard/Electra

1

-

-

... More
All as per item No. 12 above but capacity 100 to 200 KVA. Make of Stabilizer : M Guard/Vinitec/Volina

1

-

-

... More
S & F in replacement Volt Meter, analog type, range from 0 to 660 Volts, suitable /compatible to existing Servo Voltage Stabilizer, Oil Cooled type of capacity 25 to 75 KVA.complete all as specified and directed Make of Stabilizer : M Guard/Electra

1

-

-

... More
All as per item No. 14 above but capacity 100 to 200 KVA. Make of Stabilizer : M Guard/Vinitec/Volina

1

-

-

... More
S & F in replacement control wiring of 1.5 Sqmm single core multi-stranded FRLS copper conductor insulated with heat shrinkable PVC sleeve tagged and secured for indicators / meters/Voltage Stabilizers etc including suitable size of copper lugs, PVC cable ducts, galvanised or cadmium plated high tensile nuts, bolts and washers etc complete all as specified and directed.

35

-

-

... More
Supply and top up of voltage stabilizer oil with di-electric strength not less than 50 KV in to the body tank of the voltage stabilizer at various locations complete all as directed by the Engineer-in-Charge and also submit the test result before and after the top up. Make : Poweroil/ Transol/ Sabitha Chemicals]

1200

-

-

... More
S & F in replacement ampere meter including suitable size of CTs, ring type, 240 Volts, 50 Hz, AC, suitable /compatible to existing Servo Voltage Stabilizer, Oil Cooled type of capacity 25 to 75 KVA.complete all as specified and directed Make of Stabilizer : M Guard/Electra

3

-

-

... More
All as per item No. 18 above but capacity 100 to 200 KVA. Make of Stabilizer : M Guard/Vinitec/Volina

2

-

-

... More
Supply and re-winding Super enamelled Copper winding wire as per sample given or suitable / compatible to existing servo voltage stabilizer, Oil Cooled type of any capacity/ make and re-winding the defective coils/dimmer assembly with new copper wire as per relevant I.S. of same gauge and existing size together with new insulated materials/ bracings before placing in to the voltage stabilizer and assembling the coil with new insulation and fitting the coils in the chamber, testing and commissioning the voltage stabilizer and recording the test results complete all as specified and directed

130

-

-

... More
M & L for replacement Super enamelled Iron core as per sample or suitable/compatible to existing Servo voltage stabilizer, Oil Cooled type of any capacity/make by re-assembling the defective iron core with new iron core as per relevant I.S. of same gauge and existing size together with new materials/ bracings before placing in to the voltage stabilizer and assembling the iron core with new insulation and fitting the coils in the chamber, testing and commissioning the voltage stabilizer and recording the test results complete all as specified and directed

100

-

-

... More
M & L for re-insulation/re-varnishing of super enamelled copper winding wire of existing copper winding/dimmer stat assembly or suitable/compatible to existing Servo voltage stabilizer, Oil Cooled type of any capacity/make by re-assembling the defective Copper winding with new copper winding as per relevant I.S. of same gauge and existing size together with new materials/ bracings before placing in to the voltage stabilizer and assembling the Copper winding/dimmer stat assembly with new insulation and fitting the coils in the chamber, testing and commissioning the voltage stabilizer and recording the test results complete all as specified and directed

80

-

-

... More
M & L for dehydration/filteration of voltage stabilizer oil at site by taking proper shutdown of various capacity of Voltages Stabilizers located at various Sub Stations inside NDA, desired di-electric strength of oil not less then 50 KV complete all as directed and specified and also submit the test result before and after the de-hydration of the stabilizer oil complete all as specified and directed.

4000

-

-

... More
Preventive Maintenance and servicing by opening the top cover of the Voltage stabilizer, air cooled type, capacity 20 KVA, 415 Volts, 50 Hz, AC and checking the all control wiring and cleaning internally by applying air pressure through blower and ensure testing voltage, current, Earthing, \Minor patrs etc complete all as specified and directed. Make of Stabilizer : AE. Note : Servicing must be done through OEM or authorised personnel.

4

-

-

... More
M&L for preparation of existing surface of Voltage stabilizer 500 KVA, Oil Cooled type by srapping down /peeled off old paint, loose scale grease, Lubricants etc by abrasive paper and applying one coat of smoke gray paint by spray complete all as specified and directed

2

-

-

... More
All as per item No. 25 Above but Capacity 200 KVA.

3

-

-

... More
All as per item No. 25 Above but Capacity 100 KVA.

2

-

-

... More
All as per item No. 25 Above but Capacity 75 KVA.

1

-

-

... More
All as per item No. 25 Above but Capacity up to 50 KVA.

4

-

-

... More
Preventive Maintenance and servicing by opening the top cover of the Isolation Transformer, Air Cooled type, Capacity 75 KVA, 415 Volts, 50 Hz, Checking all control wiring and cleaning internally by applying air pressure through blower and ensure testing voltage, current, Earthing etc complete all as specified and directed. Make : Urja. Note : Servicing must be done through OEM or authorised personnel.

1

-

-

... More
M&L for preparation of existing surface of Voltage stabilizer 20 KVA, Air Cooled type by srapping down /peeled off old paint, loose scale grease, Lubricants etc by abrasive paper and applying one coat of smoke gray paint by spray complete all as specified and directed .

4

-

-

... More
S & F Brass/Gun Metal Gate Valve of size 25 mm dia with iron wheel head or suitable /compatible to existing 500 KVA Voltage stabilizer, Oil Cooled type by cutting/screwing /Threading/ welding etc for drain out and control of Stabilizer oil including drain out the complete voltage stabilizer oil and kept safely in container /drum/barrel and re-fill the same oil into the same stabilizer after completion of fixing work of drain valve including rectification of oil leakages noticed, if any complete all as specified and directed

2

-

-

... More
All as per item No. 32 Above but Capacity 200 KVA.

1

-

-

... More
All as per item No. 32 Above but Capacity 100 KVA.

1

-

-

... More
M & L for Preventive Maintenance / Servicing of Dynamically Balanced Siren with Motor heavy duty of Capacity 3 HP, 3-Ph, 440 V, 50 Hz, AC by opening the siren complete including correcting defects like alignment of wheel /shaft, cleaning of fins, worn out bearing and shaft as per existing size and make siren serviceable incl greasing cleaning and testing etc including taking down from existing place i.e MP Block Tower and re-installed at same place after completeion of servicing complete all as specified and directed by Engineer-in-Charge for entire satisfaction. Note :- (i) Rates quoted against the Item is deemed to be included for cost of labour, cost of T & P required for replacement of unserviceable parts and cost of handling / transportation of defective item to & from OEM workshop for repair/servicing. (ii) Cost of Spares used and rewinding motor if any will be measured and paid separately under respective item of BOQ. Name of OEM : Kheraj Electrical Industries (P) Ltd.

1

-

-

... More
Supply of Ball/Roller bearing No. 6204, ISI Marked, or suitable/compatible to existing Dynamically balanced siren, capacity 3 HP, 3-Ph, 440 Volts, 50 Hz complete all as directed.

4

-

-

... More
Supply of shaft made up of SS or suiatble/cpmpatible to existing Dynamically balanced siren, capacity 3 HP, 3-Ph, 440 Volts, 50 Hz complete all as directed.

1

-

-

... More
S & F inreplacement of Industrial Grade 5 KVA single Ph Servo Stabilizer With inbuild Isolation Transformer I/p (170-230) VAC O/p 230+/-1% 5 KVA capacity single phase 230 Volt with all connected accessories all as directed by Engr-In-Charge.

2

-

-

... More
M & L in replacement of 110- 240 V +15% AC, 50 Hz input and 12V DC, 20 Amp output SMPS suitable to existing system of tower clock LED illumination of the dial (indices) complete all as specified and directed. Make : S-Light

3

-

-

... More
M & L in replacement of 110- 240 V +15% AC, 50 Hz input and 12V DC, 5 Amp output SMPS suitable to existing system of tower clock LED illumination of the dial (indices) complete all as specified and directed. Make : JBN, Model No. JBN1205

4

-

-

... More
S & F in replacement of back up system of 12 volts, 12 Ah capacity dry type, maintenance free sealed battery, suitable/compatible to existing tower clock system complete all as specified and directed. Make : Chloride Safepower/Trontek

5

-

-

... More
S & F in replacement of digital timer switch, suitable for working between 110 to 240 V, AC, 50 Hz and capable for setup of 25 programs or suitable/compatible to existing tower clock system and also for siren complete all as specified and directed. Make : L & T or its equivalent.

4

-

-

... More
Preventive Maintenance / Servicing of Hydraulic Ladder by opening the Side PTO Links, Left and Right movement Switches, Up and down movement switches, all bends and joints and moveable parts of Hydraulic Ladder and applying grease, lubricants, oil seals etc complete including correcting defects like alignment of wheel /shaft and gear assembly, born out bearing as per existing size and make hydraulic ladder serviceable and testing etc., complete all as specified and directed Note :- (i) Rates quoted against the Item is deemed to be included for cost of labour, cost of T & P required for replacement of unserviceable parts and cost of handling / transportation of defective item to & from OEM workshop for repair/servicing. (ii) The Major Spares used if any will be measured and paid separately under respective item of BOQ. (iii) This Job Must be done through OEM or authorised rep. OEM of Hydraulic Ladder : Hi-Tech Services

1

-

-

... More
Supply & top up of hydraulic oil of Hydraulic ladder as per OEM recommendation complete all as specified and directed and it shall be carried out through OEM. Make of Hydraulic Ladder : Hi-tech

60

-

-

... More
M & L to arrest and rectify the defects of hydraulic oil leakages from Side PTO Links, Left and right switches, Up and Down switches etc of Hydraulic Ladder including replacement of all defective Parts i.e Oil seals, linkages etc complete all as specified and directed and this job must be carried out through OEM. OEM of Hydraulic Ladder : Hi-tech Services

4

-

-

... More
M & L for preparation of existing surface of Hydraulic Ladder by scrapping down, peeled off old paint with abrasive paper including applying one coat of existing colour by spray painting complete all as specified and as directed.

1

-

-

... More
S & F in replacement of LED indicator lamp Red/Yellow/Blue size and capacity as per existing including drilling and cutting the panel sheet if required complete all as directed.

35

-

-

... More
S & F in replacement of Cylindrical panel locks size as per existing including cutting and drilling the panel sheet if required complete all as directed.

40

-

-

... More
S & F in replacement of Cold rolled mild steel hinges suitable to existing APFC panel door or as per sample including cutting/welding to panel sheet and painting to match with the existing colour complete all as directed.

35

-

-

... More
M & L for preparation of existing surface of APFC Panel/LT Panel by scrapping down, peeled off old paint with abrasive paper including applying one coat of smoke grey paint by spray or as directed including cleaning the APFC Panels/LT Panels from inside by blowing the air through blower complete all as directed.

150

-

-

... More
M & L for demolition of un-reinforced PCC, floors etc in any position and any description including removal of demolished material atleast 100 mtr away from site complete all as directed.

8

-

-

... More
M & L for Plain Cement Concrete (1:3:6) type C2 (40 mm graded aggregate) for foundation, filling and mass concrete including necessary form work etc complete all as directed.

8

-

-

... More
S & F in replacement of Aluminium lugs including opening the cable from panel/Busbar and reterminated the same as per existing system, suitable/compatible to 10 Sqmm AL stranded cable complete all as directed.

30

-

-

... More
All all as per item No. 53 Above but 16 Sqmm

30

-

-

... More
All all as per item No. 53 Above but 25 Sqmm

36

-

-

... More
All all as per item No. 53 Above but 35 Sqmm

36

-

-

... More
All all as per item No. 53 Above but 50 Sqmm

32

-

-

... More
All all as per item No. 53 Above but 70 Sqmm

32

-

-

... More
All all as per item No. 53 Above but 95 Sqmm

30

-

-

... More
All all as per item No. 53 Above but 120 Sqmm

30

-

-

... More
All all as per item No. 53 Above but 150 Sqmm

26

-

-

... More
All all as per item No. 53 Above but 185 Sqmm

22

-

-

... More
All all as per item No. 53 Above but 240 Sqmm

20

-

-

... More
All all as per item No. 53 Above but 300 Sqmm

20

-

-

... More
All all as per item No. 53 Above but 400 Sqmm

15

-

-

... More
S & F in replacement of LT jumper made up of Aluminium Counductor Steel Reinforced with the help of suitable size of winding wire, clamps, connector etc. The length of jumper shall not be less than 3 meter on LT OH Conductor complete all as specified and directed by Engineer in charge.

25

-

-

... More
Supply and fixing nuts, bolts and washers made up of GI or Cadmium plated, high tensile as per sample complete as directed.

10

-

-

... More
S & F Aluminium Ferruels of reputed brands and superior quality, suitable/compatible to 10 to 16 Sqmm AL stranded LT power cable complete all as directed.

28

-

-

... More
All all as per item No. 68 Above but 25 to 35 Sqmm

22

-

-

... More
All all as per item No. 68 Above but 50 to 70 Sqmm

35

-

-

... More
All all as per item No. 68 Above but 95 to 120 Sqmm

32

-

-

... More
All all as per item No. 68 Above but 150 to 185 Sqmm

18

-

-

... More
All all as per item No. 68 Above but 240 to 400 Sqmm

20

-

-

... More
S & F junction box inner dimension approx 270mm X 225mm X 135mm (HxWxD), 3 phase, 4-wire system, including 6 Amp MCB DP with mounting channel, cable connecting base, Cable lugs of suitable to 16/10 Sqmm 4 core cable, cable connection for incoming and outgoing cable etc including fixing arrangements at tubular poles/walls with suitable size of strip, nut-bolts etc complete all as specified and directed by Engr-in-Charge. Make : National/Sintex or its equivalent as approved by GE.

15

-

-

... More
Supply & Laying in replacement Synthetic Rubber Insulated Mats of 2.5 mm thick for Voltage upto 11KV of size 2x1M working pressure conforms to IS 15652-2006 and applying adhesive to fix before laying the new one complete all as specified and directed.

5

-

-

... More
M & L in replacement for Synthetic insulation mat of size 2m x 1m x 19mm complete all as directed.

12

-

-

... More
M & L for removing deteriorated existing stone aggregate of any size and type from Sub Stn Yard by excavating upto the natural ground surface and depositing where directed and cleaning the complete sub stn yard, removing tree roots, sepplings, grass etc and spreading 1'' layer of lime relay in the same Sub Stn Yard complete all as specified and directed by the Engr-in-charge.

230

-

-

... More
M&L for 40 mm graded stone aggregate for evenly spreading at sub station yard upto the required thickness from natural ground level complete all as directed by Engineer in Charge

70

-

-

... More
M & L for 20 mm graded stone aggregate for evenly spreading at sub station yard upto the required thickness from natural ground level complete all as directed by Engineer in Charge

160

-

-

... More
M & L for servicing and repairing of Gang Operating Device by taking proper shutdown and applying petrolium jelly on male female contacts, tightning Nut, Bolts and washers and also Jumpers, lightning arrestors, etc including one coat of Aluminium paint on complete 2 pole structure i.e. Tubular pole, MS Channel etc complete all as specified and directed

10

-

-

... More
M&L in replacement Pin type porcelain vitreous white brown or green insulator including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut 100 mm height 65 mm dia 1100 volts grade including taking down complete all as specified and directed.

22

-

-

... More
M&L in replacement Shackle type porcelain vitreous white brown or green insulator including one galvanised mild steel straps washers insulators bolts washers and nut as under 75 mm height and 90 mm dia 1100 volts grade including taking down complete all as specified and directed

25

-

-

... More
M & L for End Jointing Kit suitable for 3 Core 95 Sqmm XLPE HT armoured aluminium conductor cable (earthed) grade for indoor termination heat shrink type joint complete with jointing material and accessories including taking shut down and opening the cable from both side of Bus Bar Panel/VCB/RMU/GOD etc and re-terminated the same cable in the same Bus Bar Panel/VCB/RMU/GOD etc after completion of jointing work complete all as specified and directed.

3

-

-

... More
M& L for End jointing kit suitable for 3 Core 95 Sqmm XLPE HT armoured aluminium conductor cable (Earthed) grade for outdoor termination heat shrink type joint complete with jointing material and accessories including taking shut down and opening the cable from both side of Bus Bar Panel/VCB/RMU/GOD etc and re-terminated the same cable in the same Bus Bar Panel/VCB/RMU/GOD etc after completion of jointing work complete all as specified and directed.

2

-

-

... More
M & L for Straight Through jointing kit suitable for 3 core 95 Sqmm XLPE 11 KV HT armoured aluminium conductor cable (Earthed) grade for straight through termination heat shrink type joint complete with jointing material and accessories including taking shut down and opening the cable from both side of Bus Bar Panel/VCB/RMU/GOD etc and re-terminated the same cable in the same Bus Bar Panel/VCB/RMU/GOD etc after completion of jointing work complete all as specified and directed.

3

-

-

... More
M&L for replacement of earthing complete with galvanised steel earth plate electrode 60x60cmx6mm GI thick burried directly in ground ( earth plate pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised iron strip 25x4 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 of SSR Part-I 2009 connected to eqpts/panel etc complete all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil strata and pit re-filled with Charcoal, Salt and black cotton soil. PCC chamber (1:3:6) type C1, PCC pit cover, funnel with wiremesh including 20mm dia medium grade GI Pipe for watering complete all as directed.

12

-

-

... More
M&L in replacement of GI strip 25 x 4 mm as earth continuity conductor or main earthing lead fixed to wall batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation with suitable size of SMC/FRP Insulators at suitable gaps, nut, bolts and washers etc complete all as specified and directed.

80

-

-

... More
Pruning / trimming of branches of trees interfering or overhanging electrical overhead lines in such a way to have a clearance of not be less than 2 mtrs from the outermost conductors on both side including thrown away the same atleast 100 mtr from the site complete all as specified and directed by Engr-in-Charge. Note : Span of conductor shall be measured from insulator to insulator without allowance for overlapping.

60

-

-

... More
S & F in replacement of HT jumpering with the help of Aluminium Counductor Steel Reinforcement covered with insulating material/sleeve and suitable size of aluminium Lugs, nut, bolt and washers etc. The length of jumper shall not be less than 3 meter including connection with the help of connector on the HT pole complete all as specified and directed by Engineer in charge

15

-

-

... More
S & F in replacement Busbar panel weather proof outdoor type single door, fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7032 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars, shall not be less than 400 Amps current rating, electrolytic grade including required size of nut bolts for fixing of cables upto 240 Sqmm. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding and fix horizontally. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment and provision of cable glands, thimbles etc. All joints and connection shall be done with galvanised or cadmium plated high tensile nuts, bolts and washers. The panel shall be provided with 04 Nos 50mmx50mmx5mm thick angle iron supports of not less than each 1.0 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement. Including cable connection and providing 4 Nos cable entry holes. The overall size of the Busbar panel shall not be less than 500mmx300mmx700mm (LxWxH) including earthwork all as directed and specified by Engr in Chrage. Note : (i) 4 Nos of Entry holes for cables from bottom side shall be provided upto 400 Sqmm and each busbar shall be provided neccessary arrangement to connect 4 Nos of cables including Nut bolts etc

10

-

-

... More
S & F in replacement Busbar panel weather proof outdoor type single door, fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7032 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars of 300 Amps current rating. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding and fix horizontally. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment and provision of incoming and outgoing cable. All joints and connection shall be done with galvanised or codmium plated high tensile nuts, bolts and washers. The panel shall be provided with 04 Nos 25mmx25mmx4mm thick angle iron supports of not less than each 1 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at uitable depth as per site requirement. The overall size of the Busbar panel shall not be less than 400mmx200mmx550mm (LxDxH).including earthwork all as directed and specified by Engr in Chrage. Note : (i) 4 Nos of Entry holes for cables from bottom side shall be provided upto 185 Sqmm and each busbar shall be provided neccessary arrangement to connect 4 Nos of cables including Nut bolts etc

6

-

-

... More
S&F in replacement of GI bracket suitable for LED street light fitting including suitable size of clamps, nuts, bolts etc and fitted on the street light pole including taking down existing one complete all as specified and directed

25

-

-

... More
S & F in repalcement LED Street Light 60 W, 230 Volts, AC Outdoor type made up of pressure die cast housing with individual LEDs with modular secondary optics and IP 55 protection, including taking down existing one complete all as specified and directed.

25

-

-

... More
S & F in repalcement of LED Post tops 40 W, 230 Volts AC, Outdoor type, made up pressure die cast aluminium housing with decorative clear opal acrylic diffuser and IP65 protection including taking down existing one complete all as specified and directed. Make : Bajaj Cat Part No BGCT W4 LED or equivalent make as specified under makes list in PS

18

-

-

... More
S & F in replacement PVC insulated copper cable 3 core 1.5 sqmm multi-stranded for security light/street light and to be drawn through properly hole of street light pole including making of 10mm dia 2 hole in street light pole i.e. 01 x top and 01 x bottom of the pole and taking down existing one complete all as specified and directed.

220

-

-

... More
Labour for restretching/tightening the existing LT overhead conductors & GI earth wire mounted on insulators of any type on poles manually or by mechanical means to the extent of permissible sag and tension and binding with steel wires of appropriate size complete having 5 to 7 conductors per span of approx 35-40 mtr length all as specified and directed by Engr-in-Charge.

45

-

-

... More
M&L in replacement aluminium conductor steel reinforced size according to site requirement fixing on the over head LT pole with the help of aluminium tapes/ binding wire including taking down existing one complete all as specified and directed

1.5

-

-

... More
Supply & laying in replacement including, fixing on walls, floors with suitable size of GI Clamps, nuts, bolts and washers etc of LT cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with multi-stranded aluminium conductor of following sizes:- Note - Excavation / earthwork, Bricks Cable Cover & sand cushioning will be measured and paid separately under respective item of sch A. (a) 4 Core 10 Sqmm

235

-

-

... More
( b) All all as per item No 98 above but 4 Core 16 Sqmm

250

-

-

... More
(c)All all as per item No 98 above but 3.5 Core 25 Sqmm

200

-

-

... More
(d)All all as per item No 98 above but 3.5 Core 35 Sqmm

160

-

-

... More
(d)All all as per item No 98 above but 3.5 Core 50 Sqmm

250

-

-

... More
(e)All all as per item No 98 above but 3.5 Core 70 Sqmm

200

-

-

... More
(f)All all as per item No 98 above but 3.5 Core 95 Sqmm

220

-

-

... More
(g)All all as per item No 98 above but 3.5 Core 120 Sqmm

150

-

-

... More
(h)All all as per item No 98 above but 3.5 Core 150 Sqmm

160

-

-

... More
(j)All all as per item No 98 above but 3.5 Core 185 Sqmm

80

-

-

... More
(k)All all as per item No 98 above but 3.5 Core 240 Sqmm

100

-

-

... More
Excavation in trenches, n.exc 1.5m wide and n. exc 1.5 m depth and getting out in for foundation of pole, stay, laying of cable and pipe etc : soft/loose soil complete all as specified and directed

333.9

-

-

... More
All all as per item No 109 above but Hard/Dense soil

143.1

-

-

... More
Returning and filling in, including spreading and well ramming in layers n exc 25 cm all as specified and directed.

240.49

-

-

... More
Removing excated material a distance n. exc 50 m & depositing where directed at a level n. exc 1.5 m above the starting point.

236.51

-

-

... More
M&L for dry crush sand cushioing to under ground cable intrenches incl spreading, leveling and hand punning complete all as specified and as directed. Note : For measurement purpose punned thickness shall be considered.

162.34

-

-

... More
Supply and laying common burnt clay building sub class B old size bricks, laid in right angle along the cable, complete all as specified and directed

20.91

-

-

... More
M & L in replacement for laying of half round unreinforced concrete pipe of size, inner dia 150 mm and Outer dia 200 mm, half round for bottom and half round for top and before laying excavated area shall be leveled, complete all as specified and directed. Note : 01 Half round top and 01 half round bottom together will be considered as one running meter. Make :As per sample approved by Engr-In-Charge.

190

-

-

... More
Supply and lay in replacement of G.I pipe light grade with all fittings required for protection of under ground cable of 100 mm dia complete all as specified and directed

12

-

-

... More
All all as per item No 116 above but 80 mm dia

18

-

-

... More
All all as per item No 116 above but 50 mm dia

36

-

-

... More
M&L for road cutting size according to site requirement for laying pipe and crossing cable etc including make good with existing material or with PCC 1:2:4 type B1 complete all as specified and as directed.

30

-

-

... More
Relaying serviceable LT UG cable of following sizes complete all as specified and directed. Note - Excavation / earthwork, cable protection covers & sand cushioning will be measured and paid separately under respective item of sch A. (a)4 Core 10 Sqmm

60

-

-

... More
(b)All all as per item No 120 above but 4 Core 16 Sqmm

80

-

-

... More
(c)All all as per item No 120 above but 4 Core 25 Sqmm

50

-

-

... More
(d)All all as per item No 120 above but 3.5 Core 35 Sqmm

70

-

-

... More
(e)All all as per item No 120 above but 3.5 Core 50 Sqmm

80

-

-

... More
(f)All all as per item No 120 above but 3.5 Core 70 Sqmm

60

-

-

... More
(g)All all as per item No 120 above but 3.5 Core 95 Sqmm

50

-

-

... More
(h)All all as per item No 120 above but 3.5 Core 120 Sqmm

70

-

-

... More
(j)All all as per item No 120 above but 3.5 Core 150 Sqmm

60

-

-

... More
(k)All all as per item No 120 above but 3.5 Core 185 Sqmm

45

-

-

... More
(l)All all as per item No 120 above but 3.5 Core 240 Sqmm

50

-

-

... More
(m)All all as per item No 120 above but 3.5 Core 300 Sqmm

40

-

-

... More
(n)All all as per item No 120 above but 3.5 Core 400 Sqmm

25

-

-

... More
M&L for straight through Jointing Kit, heat shirnkable type complete with all jointing materials and suitable for 1100 Volts XLPE LT UG Power Cable aluminium stranded conductor of sizes cable 3.5 Core 300 Sqmm including taking shut down and opening the cable from both side of Bus Bar/Feeder Panel/LT Panel/ACB etc and re-terminated the same cable in the same Bus Bar/Feeder Panel/LT Panel/ACB etc after completion of jointing work according to existing system complete all as specified and directed.

2

-

-

... More
All all as per item No 133 above but 3.5 Core 240 Sqmm

3

-

-

... More
All all as per item No 133 above but 3.5 Core 185 Sqmm

2

-

-

... More
All all as per item No 133 above but 3.5 Core 150 Sqmm

3

-

-

... More
All all as per item No 133 above but 3.5 Core 120 Sqmm

4

-

-

... More
All all as per item No 133 above but 3.5 Core 95 Sqmm

4

-

-

... More
All all as per item No 133 above but 3.5 Core 70 Sqmm

3

-

-

... More
All all as per item No 133 above but 3.5 Core 50 Sqmm

4

-

-

... More
All all as per item No 133 above but 3.5 Core 35 Sqmm

3

-

-

... More
All all as per item No 133 above but 3.5 Core 25 Sqmm

3

-

-

... More
All all as per item No 133 above but 4 Core 16 Sqmm

4

-

-

... More
All all as per item No 133 above but 4 Core 10 Sqmm

3

-

-

... More
S & F in replacement of AC supply power contactor MNX140 (2 NO + 2NC) type, 140 Amps, 3-Pole, 415 Volts, 50 Hz, complete all as specified and directed.

1

-

-

... More
M & L for core cutting, boring/ drilling in any type of walls (i.e Stone walls etc) of suitable dia for passing the LT Cables of size from 10 Sqmm to 400 Sqmm, Earth conductors etc including filling/making good to the disturbed surface of walls with existing one complete all as directed.

1

-

-

... More
S & F in replacement MCCB 3P 400 Amps, 36 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu including suitable size of spreader links with galvanised or codmium plated high tensile nuts, bolts and washers etc including cutting of panel Sheet and drilling also without disturbing to the existing accessories complete all as specified and directed.

1

-

-

... More
All as per item No. 147 But 3P 250 Amps, 36 KA.

1

-

-

... More
All as per item No. 147 But 3P 200 Amps, 36 KA. Make : L&T/Legrand

2

-

-

... More
All as per item No. 147 But 3P 160 Amps, 36 KA. Make : L&T/Legrand

2

-

-

... More
All as per item No. 147 But 3P 100 Amps, 16 KA. Make : L&T/Legrand

3

-

-

... More
All as per item No. 147 But 3P 63 Amps, 16 KA. Make : L&T/Legrand

4

-

-

... More
Supply and Installation in replacement of lead acid DC battery 12 Volts, 180 AH complete with electrolyte and initial charge with required size of lugs and terminal cap etc including taking down existing one complete all as specified and directed. Make : Exide/Amron

3

-

-

... More
M & L for Preventive maintenance and servicing of Lead Acid DC battery, 12V, 180Ah capacity complete with electrolyte, toping up of distilled water in batteries as per site reqirement and initial charge installed at various Sub Stns inside NDA Campus complete all as specified and directed by Engr-in-Charge. Note :- The rates quoted against the item is deemed to be included for cost of Labour, cost of T & P required for servicing and cost of handling / transportation of defective item to and from Civil workshop for repair / servicing. Make : Exide/Amaron

6

-

-

... More
Preventive maintenance and servicing of 11 KV HT, 200 Amp Load Break Switch, cleaning from inside and outside by using CRC-26 spray applying petrolium jelly to moveable parts, Male /female bushing/ terminals/ Spouts of switchgear. Complete servicing of switchgear including checking the fixed / moving contacts of all the 3 phases adjusting electrical/ electronic/mechanical components all as per mfg instruction manual and standard practice including testing complete. Make of Switchgear : GC Lucy as OEM

1

-

-

... More
Labour for cleaning the complete Sub Stn Yard of size (20 x 15) Mtr approx including fencing and 1 mtr all around the Sub Stn fencing by removing/cutting/digging out from roots of trees, bushes & sepplings etc and thrown away the waste atleast 100 mtr away from the sub stn yard complete all as directed by Engr-in-Charge.

26

-

-

... More
Supply & Laying in replacement of GI tubing Medium Grade 15 mm bore in trenches or fixing on wall/floor/ceiling with all standard fittings such as suitable size of MS clamps, screws, hooks, Elbow, bends, tees etc complete all as directed. Note : Excavation and Earth work shall be measured and paid separately.

200

-

-

... More
S & F in replacement of Bronze/Gun Metal Gate Valves (Hexagonal type) 15 mm bore with iron wheel head, screwed both ends for iron pipe and fixed complete all directed.

6

-

-

... More
S & F in replacement of Stop Cock of any colour, 15 mm dia, screwed for pipes high pressure (minimum weight 90 gms) complete all as specified and directed

21

-

-

... More
M&L for cleaning the drain, size (0.5 x 1.0) Mtr (W x D) including dug out and removing the Rubbish/mud/ foreign materials and thrown away the same atleast 100 mtr from the MRS Compound complete all as specified and directed

25

-

-

... More
M&L for tree branch cutting of high rise trees, overhanging/interferences to the Two/Four Pole Structure GODs (size of tree branch approx 80 mm to 300 mm dia) without damages to the Two/Four Pole Structure/GODs etc including thrown away the same alteast 100 Mtr away from the Sub Stn Yard complete all as directed. Note : Suitable arrangement i.e ladder, scafolding or any other working plateform required for climbing on high rise trees for carryout said work is the responsibility of vendor/contractor and the rates are deemed to be included in this quoted rate.

20

-

-

... More
Supply & Fix in replacement of APFC controller relay, 415 V, 6 steps with auto and amnual switch off, modular and expendable steps, large backlite LCD display with user friendly interface, CTs secondary 5A site selectable, measurement of individual current and voltage upto 15th order, suitable for LV side sensing, communicable on modus RS 485 with the help of RS-485 plug in module including control wiring with suitable size of copper wire etc complete all as specified and directed .

2

-

-

... More
Supply & Fix in replacement of APFC controller relay, 415 V, 8 steps with auto and amnual switch off, modular and expendable steps, large backlite LCD display with user friendly interface, CTs secondary 5A site selectable, measurement of individual current and voltage upto 15th order, suitable for LV side sensing, communicable on modus RS 485 with the help of RS-485 plug in module including control wiring with suitable size of copper wire etc complete all as specified and directed .

1

-

-

... More
S & F in replacement of illuminated display board of size (1.28 x 0.2 x 0.9) Mtr (L x B xH) with Flex of Light Blue (MES Colour), Colour of letters shall be white, outerside fabrication bordered with Aluminium angle Frame of size (20 x 20) mm x 3mm thick, innerside fabricated with 12mm MS square bar and aluminium sheet for top, bottom, back side, left side and right side of the display board, 50mm dia GI Pipe medium grade shall be fixed both side of board with 2 Nos 30 mm x 4mm thick MS flat of 0.2 Mtr length welded to GI pipe and nut bolt and washer with display board not less than 2.5 Mtr and PCC 1:4:8 for foundation including all internal wirings and illuminated with LED 40 W Tubelight fitting 01 No, SMC/FRP Junction Box 140mm x 140mm x 95mm inner dimension make Sintex/National, the board must be openable from back side for maintenance of tube light, control wiring etc. Make : Bajaj Cat Part No BCLAB 20W /Wipro/Havells including its fixing arrangement and written Letters in capital not less than 10 letters and more than 40 letters, size of letters proportion with overall size of board complete all as specified and as directed. Note : (i) Before manufacturing Boards drawing and design of Board including colour of board shall be approved by Engr-in-charge. (ii) Each board display name shall be given seperately.

4

-

-

... More
Fixing in repair illuminated display board of size (1.28 x 0.2 x 0.9) Mtr (L x B xH) with Flex of Light Blue (MES Colour) and grouted with PCC 1:4:8 for foundation including change all internal wirings and LED 40 W Tubelight fitting 01 No, SMC/FRP Junction Box 140mm x 140mm x 95mm inner dimension make Sintex/National complete all as specified and as directed.

8

-

-

... More
M & L for scrapped down/peeled off old paint with abrasive paper and applying two coats of synthetic enamel paint of post office RED Colour on both side of board (size 1.5m x 1.5m) and re-writing the letters as "SAVE WATER SAVE ELECTRICITY" with White paint according to existing size of letters and two coats of black paint on its border and two fixing supports of MS round pipe of height 2.5 mtr complete all as specified and directed. Note : This job shall be carried out through experienced Painter and decorator.

2

-

-

... More
Supply only bamboo Ladder suitable for climbing upto 7.0 Mtr height complete all as specified and directed . Make : as per sample.

4

-

-

... More
Supply only Insulation tape roll size 18mm width and 6.5 Mtr length of superior quality complete all as specified and directed . Make : as per sample.

320

-

-

... More
Labour for cleaning the 3 mtr sarrounding area of LT Panel/Feeder Panel/Bus Bar Panel by removing/cutting out from roots of trees, bushes & sepplings etc and thrown away the same atleast 100 mtr away from the site complete all as specified and directed

260

-

-

... More
M&L in repair of Solar PV modules multi-crystalline panel of size (2.0x1.0) Mtr and capacity 310 WP/ 24V, installed at various security posts along boundary wall of NDA complete all as specified and directed . Note :- The rates quoted against the item is deemed to be included for cost of Labour, cost of T & P required for replacement of unserviceable parts and cost of handling / transportation of defective item to and from OEM workshop for repair / servicing. Make of Solar Panel : Waaree/Bikram Solar System

18

-

-

... More
Supply and Install in replacement of old damaged /broken Solar PV modules multi-crystalline panel of size (2.0x1.0) Mtr and capacity 310 WP/ 24V, suitable /compatible to existing system installed at various security posts along boundary wall of NDA complete all as specified and directed . Make : Waaree/Bikram Solar System

3

-

-

... More
S & F in repair of Solar PCU, 2 KVA, 24/4872V AC/DC hybrid input power with inbuilt MPPT charge controller, installed at various security posts along boundary wall of NDA complete all as specified and directed . Note :- The rates quoted against the item is deemed to be included for cost of Labour, cost of T & P required for replacement of unserviceable parts and cost of handling / transportation of defective item to and from OEM workshop for repair / servicing.

1

-

-

... More
M & L for Preventive maintenance and servicing of Solar LMLA tubular battries @ C10 capacity, 12V, 200AH installed at various security posts along boundary wall of NDA complete all as specified and directed. Note :- The rates quoted against the item is deemed to be included for cost of Labour, cost of T & P required for replacement of unserviceable parts and cost of handling / transportation of defective item to and from OEM workshop for repair / servicing. Make : Exide/Amron/Indo Solaris

16

-

-

... More
Supply and install in replacement of Solar LMLA tubular battries @ C10 capacity, 12V, 200Ah including all connection, installed at various security posts along boundary wall of NDA complete all as specified and directed . Make : Exide/Amron/Indo Solaris

6

-

-

... More
S & F in repair Solar module mounting structure of MS GI type (Hot dipped GI) including suitable size of high tensile nut, bolts, fastners and washers etc or suitable / compatible to existing system, installed at various security posts along boundary wall of NDA complete all as specified and directed . Note : Mounting structure will be fixed on the top of roof hence after re-fixing where fastners, bolts used for errecting the structure should be sealed properly with requisite sealent/solvent to avoid any leakage/seepage from slab.

1

-

-

... More
M & L for cleaning the glass of Solar PV modules multi-crystalline panel of size (2.0 x 1.0) Mtr (06 x Panels per security post along boundary wall of NDA) and capacity 310 WP/ 24V by removing the mud/algee/foreign materials from the panel complete all as directed. Note : If any damages noticed during this job, the contractor shall remain responsible to make good without any extra cost to the deptt. Make : Waaree/Bikram Solar System

7

-

-

... More
M & L for top up of distilled water in battries upto required level at every 3 months intervals at site i.e. Various security posts along boundary wall of NDA complete all as specified and directed

465

-

-

... More
S & F in replacement of MCB 4 Pole, Change over type, 415 Volts, 50 Hz, 40 Amp, 10 KA, C-Curve conforms to IS/IEC 60898 including taking down existing one and install with mounting rail, links etc complete all as specified and directed.

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.