Military Engineer Services Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date27 Jan 2025
Closing Date25 Feb 2025
Tender Amount₹ 50,93,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
350 KVA, Make - Pactil

1275

-

-

... More
Preventive Maintenance and Servicing of 22/0.415 KV Power Transformer of following make & capacity, outdoor type by disconnecting carefully electric connection on primary & secondary side by disconnecting incoming and outgoing HT/LT cables/sandwitch duct connection and remove the transformer tank top cover/lid, draining out the transformer oil and keeping in safe custody in clean and dry containers for reuse. and carrying out the maintenance work by experienced and qualified Engineer, dismantling the OLTC, dismantling HT/LT bushings from core winding and lifting the core assy carefully without damaging by using the tripod/ chainpully/crane etc, cleaning / removing the sludge from the transformer tank, cleaning the OLTC and checking the serviceability of the coil / core winding, checking the condition of the body, cleaning the coil/core assy, refixing of core/core assy, OLTC, HT/LT winding connection, connection of protective devices like buckholz relay connection, winding temperature indicator, oil temperature indicator including fixing new gaskets to transformer top and all other places gaskets/washer, terminal studs of HT/LT sides and re-assembling of transformer after repairs, refitting the transformer coil incl improvement of insulation resistance value within desired level by heating or any other method to required level complete all as directed and to the entire satisfaction of GE / E-in-C. (Note- Filteration of oil will be measured and paid separately)

-

-

-

... More
2000 KVA, Make - Voltamp

4

-

-

... More
500 KVA, Make - Voltamp

2

-

-

... More
350 KVA, Make - Pactil

1

-

-

... More
S&F HT bushing suitable for 22/0.415 KV Transformers including dismantling old one of following capacity and make :-

-

-

-

... More
2000 KVA, Make - Voltamp

3

-

-

... More
500 KVA, Make - Voltamp

3

-

-

... More
350 KVA, Make - Pactil

3

-

-

... More
S&F LT bushing suitable for 22/0.415 KV Transformers including dismantling old one of following capacity and make :-

-

-

-

... More
2000 KVA, Make - Voltamp

8

-

-

... More
500 KVA, Make - Voltamp

4

-

-

... More
350 KVA, Make - Pactil

4

-

-

... More
S&F copper terminal stud, both end threaded complete with double nuts and washers with heat resistant gasket suitable for LV side of 22/0.415 KV transformer including dismantling existing one of following capacity and make complete all as directed :-

-

-

-

... More
2000 KVA, Make - Voltamp

4

-

-

... More
500 KVA, Make - Voltamp

4

-

-

... More
350 KVA, Make - Pactil

4

-

-

... More
S&F copper terminal stud, both end threaded complete with double nuts and washers with heat resistant gasket suitable for HV side of 22/0.415 KV transformer including dismantling existing one for the following capacity and make complete all as directed :-

-

-

-

... More
2000 KVA, Make - Voltamp

3

-

-

... More
500 KVA, Make - Voltamp

3

-

-

... More
350 KVA, Make - Pactil

3

-

-

... More
S&F Silica gel breather suitable/compatible to 22/0.415 KV transformer including taking down existing one complete all as specified and as directed.

8

-

-

... More
M&L for repairs to transformer to arrest oil leakage by removing transformer oil, dismantling the top cover alongwith conservator tank/ OLTC, replacing the top gasket washer etc replacement of HT/LT bushes complete dismantling the cooling fins and welding where leakage to arrest oil leakage and reassembling the transformer, refilling filtered oil testing complete for transformer of following capacity & make :-

-

-

-

... More
2000 KVA, Make - Voltamp

2

-

-

... More
500 KVA, Make - Voltamp

1

-

-

... More
350 KVA, Make - Pactil

1

-

-

... More
S&F in repair Oil Temperature Indicator (OTI), suitable/ compatible to 22/0.415 KV Transformers of following capacity/make including modification required of any type and dismantling old one complete all as specified and as directed :-

-

-

-

... More
2000 KVA, Make - Voltamp

2

-

-

... More
500 KVA, Make - Voltamp

1

-

-

... More
350 KVA, Make - Pactil

1

-

-

... More
S&F in repair winding Temperature Indicator (WTI), suitable/compatible to 22/0.415 KV Transformers of following capacity/make including modification required of any type and dismantling old one :-

-

-

-

... More
2000 KVA, Make - Voltamp

2

-

-

... More
500 KVA, Make - Voltamp

1

-

-

... More
350 KVA, Make - Pactil

1

-

-

... More
Supply and topping up of transformer oil with di-electric strength not less than 45 KV into the conservator tank / body of the transformer at various Sub Stations including maintaining and submitting the test results to Engr-in-charge. (Note : (i) New Transformer oil will be filled in the transformer only after filteration and de-hydration of existing transformer oil of the transformer. (ii) Transformer oil shall be supplied in sealed container /barrel with test result and test certificate etc.)

950

-

-

... More
S&F in replacement Super enamelled Copper winding wire as per existing gauge and specifications required for repair and re-winding of 22/0.415 KV transformer of capacity 2000KVA / 500KVA / 350KVA, including testing and commissioning the transformer and recording the test results as per IS complete all as specified and as directed.

550

-

-

... More
S&F in replacement Iron Core as per existing specifications required for repair and re-winding of 22/0.415 KV transformer of capacity 2000 KVA/500 KVA/350 KVA, including testing and commissioning the transformer and recording the test results as per IS complete all as specified and as directed.

400

-

-

... More
M & L for re-insulation of Super enamelled Copper winding wire as per existing gauge and specifications required for repair and re-winding of of 22/0.415 KV transformer of capacity 2000 KVA/500 KVA/350 KVA including heating up/drying and necessary class of insulation, including testing and commissioning the transformer and recording the test results as per IS complete all as specified and as directed.

450

-

-

... More
M&L for preventive Maintenance and Servicing of Automatic Voltage Regulator and OLTC for healthy functioning of voltage tap required for LT switchgears installed for each transformer of 2000 KVA by taking shutdown of each transformer. Checking for operating mechanism, inspection of control wiring, tap changer meter, relay wiring for AVR, greasing of all moving parts of OLTC mechanism, checking and realignment of mechanism for its proper functioning and operation, re-assembling of OLTC and AVR, fixed in its original position, testing for functions, and commissioning complete all as specified and directed.

4

-

-

... More
All as per Ser. Item No. 15.00 above but for transformer of capacity 500 KVA complete all as specified and as directed.

2

-

-

... More
All as per Ser. Item No. 15.00 above but for transformer of capacity 350 KVA complete all as specified and as directed.

1

-

-

... More
S&F in replacement Main Moving Contact as per existing size and specifications required for repair of 22/0.415 KV transformer's OLTC including testing and commissioning of the transformer complete all as specified and directed.

20

-

-

... More
S&F in replacement Resistance Moving Contact as per existing size and specifications required for repair of 22/0.415 KV transformer's OLTC including testing and commissioning of the transformer complete all as specified and directed.

20

-

-

... More
S&F in replacement Fixed Contact as per existing size and specifications required for repair of 22/0.415 KV transformer's OLTC including testing and commissioning of the transformer complete all as specified and directed.

76

-

-

... More
S&F in replacement Oil Seal as per existing size and specifications required for repair of 22/0.415 KV transformer including testing and commissioning of the transformer complete all as specified and directed.

7

-

-

... More
S&F in replacement Top Cover Gasket as per existing size and specifications required for repair of 22/0.415 KV transformer including testing and commissioning of the transformer complete all as specified and directed.

7

-

-

... More
S&F in replacement Main Flange Gasket as per existing size and specifications required for repair of 22/0.415 KV transformer including testing and commissioning of the transformer complete all as specified and directed.

7

-

-

... More
S&F in replacement Bushing Board Gasket as per existing size and specifications required for repair of 22/0.415 KV transformer including testing and commissioning of the transformer complete all as specified and directed.

1

-

-

... More
S&F in replacement Bushing Board as per existing size and specifications required for repair of 22/0.415 KV transformer including testing and commissioning of the transformer complete all as specified and directed.

1

-

-

... More
S&F in replacement Automatic Voltage Regulating Relay as per existing size and specifications required for repair of RTCC of 22/0.415 KV transformer including testing and commissioning complete all as specified and directed.

1

-

-

... More
S&F in replacement Tap Position Indicator as per existing size and specifications required for repair of RTCC of 22/0.415 KV transformer including testing and commissioning complete all as specified and directed.

1

-

-

... More
S&F in replacement Sequence selector switch as per existing size and specifications required for repair of RTCC of 22/0.415 KV transformer including testing and commissioning complete all as specified and directed.

1

-

-

... More
Taking out HT VCB, 22 KV grade 1250 Amps rating from HT panel for servicing/repairs by dismantling the HT VCB operating mechamism, inspection of control wiring realignment of moving contacts with fixed contacts assy, vaccum interrupter, checking of relays for protection. greasing of all moving parts of mechanism, checking and realignment of mechanism for its proper functioning and operation, re-assembling of HT VCB, fixed in its original position, testing for functions and commissioning complete all as specified and directed.

10

-

-

... More
M&L for Calibration of 22 KV grade HT VCB relays of various types by OEM or OEM authorised dealer through primary & Secondary injection method by bringing relay test kit and other required measuring equipments to the site, after testing refixing to VCB 22 KV panel all as directed. (Note- Certificate of this test will be provided by the contractor free of cost.)

10

-

-

... More
Supply and fix in repair HT bushing spout of fibre or as per existing for 22 KV HT VCB 1250 Amp rating and removing the unsv spout complete all as directed.

9

-

-

... More
S&F Spring charging Handle suitable for 22 KV HT VCB panel complete all as directed.

2

-

-

... More
S&F in repair spring charging motor suitable for 22 KV HT VCB panel complete all as directed.

2

-

-

... More
Testing of HT current transformer (set of three) through primary current injection method and also checking the connected panel wiring by bringing required test kit and other required testing equipment and also checking tripping and closing operation complete all as specified and directed.

10

-

-

... More
Supply, install, test, commissioning of 22 KV grade HT VCB current transformer with CT ratio 200/15 or 100/5 fixed with HT VCB 22 KV including necessary cable connection etc suitable for fixing in HT panel board of Make: Schneider including modification required at site to be carried to fix CT upto recess/coils including removing the burnt CTs complete all as specified and directed.

3

-

-

... More
M & L for checking of Potential Transformer by conducting ratio test/meggering for IR values, provided in VCBs 22 KV feeders checking of control wiring meters, relay and tripping system complete all as specified and directed.

10

-

-

... More
S & F in repair PT for HT VCB 22 KV/415 volts, 100 VA burden, resin cast epoxy moulded with metal enclosure as per site requirement and connecting bus bar including providing fuse links complete all as specified and directed.

2

-

-

... More
S&F in replacement Indicating lamp (Red/Yellow/ Blue/ white) LED type including taking down existing one complete all as specified and as directed.

20

-

-

... More
S & F in replacement emergency stop button push and turn type all as specified and directed.

8

-

-

... More
S & F in replacement breaker control switch Trip-Neutral-Close type as per site requirement including taking down existing one all as specified and directed.

8

-

-

... More
S & F in replacement local remote switch suitable for HT 22 KV VCB Panel all as specified and directed.

4

-

-

... More
S&F in replacement digital voltmeter 3-phase suitable for fixing with existing HT VCB 22 KV panel complete all as directed.

3

-

-

... More
S&F in replacement digital Ammeter 3-phase suitable for fixing with existing HT VCB 22 KV panel complete all as directed.

3

-

-

... More
S&F in replacement of Digital Multifunction Meter LED, Accuracy Class 1, with RS 485 Parameters V,A,F,PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours etc. without disturbing other accessories and taking down old unserviceable meters etc complete all as specified and directed at site.

3

-

-

... More
S&F in replacement numerical type relay, 3 O/C+1 E/F with RS 485 Port suitable for fixing in existing HT VCB 22 KV panel complete all as directed.

2

-

-

... More
S&F in replacement Master trip relay, coil voltage 24 V DC suitable for fixing in existing HT VCB 22 KV panel complete all as directed.

3

-

-

... More
S&F in replacement Plug in type relay for Breaker contact multiplication, Aux contacts 2NO+2NC, coil voltage 24 V DC suitable for fixing in existing HT VCB 22 KV panel complete all as directed.

2

-

-

... More
S&F in replacement Test terminal block suitable for fixing in existing HT VCB 22 KV panel complete all as directed.

2

-

-

... More
S&F in replacement 8 window annunciator with hooter suitable for fixing in existing HT VCB 22 KV panel complete all as directed.

2

-

-

... More
S & F control wiring of 1.5 Sqmm size single core stranded FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured for indicators/ Meters etc. including suitable size of copper lugs, PVC CABLE ducts, suitable size of galvanised or cadmium plated high tensile nuts, bolts and washers etc for 22 KV VCB Panel including taking down old wiring complete all as specified and directed.

20

-

-

... More
S & F control wiring of 2.5 Sqmm size single core stranded FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured for indicators/ Meters including suitable size of copper lugs, with galvanised or cadmium plated high tensile nuts, bolts and washers etc for 22 KV VCB Panel including taking down old wiring complete all as specified and directed.

20

-

-

... More
S & F control wiring of 4 Sqmm size single core stranded FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured for indicators/ Meters including suitable size of copper lugs, with galvanised or cadmium plated high tensile nuts, bolts and washers etc for 22 KV VCB Panel including taking down old wiring complete all as specified and directed.

20

-

-

... More
S & F control wiring of 6 Sqmm Four core stranded FRLS PVC insulated copper conductor cables of including suitable size of copper lugs, with galvanised or cadmium plated high tensile nuts, bolts and washers etc for transformer, RTCC and OLTC including taking down old wiring complete all as specified and directed.

80

-

-

... More
Supply only hand gloves HT for operating / handling sub station 22 KV ISI Marked.complete all as directed.

10

-

-

... More
M&L for Servicing /Caliberation / Repairs to Air Circuit Breaker 800 to 3200 Amps by OEM of ACB only for EDO (Electrically Draw Out) type/ MDO type (Mannually Draw out type). Taking out ACB for servicing / repair and checking / caliberation of microprocessor release, Earth fault protection of 4 pole, 50 KA breaking capacity 415 volts with all draw out type mechanism, advanced self powered electronic protection units, neutral overload protection, automatic earth fault relay / over current relay, automatic safety shutter, inbuilt temperature protection, icu=ics=icw(1s)=50 KA fixed in panel complete including relay wiring checking, LT UG cable connection with main incoming ACB complete connection for its healthy functioning all as directed by Engr in charge. (Note- Certificate of Servicing /Caliberation will be provided by the contractor free of cost)

69

-

-

... More
S&F in repair shunt realease for air circuit breakers microprocessor based type suitable for existing breakers as per site make / requirement including taking out breakers after taking shutdown of electric supply complete all as specified and as directed.

16

-

-

... More
S&F in repair under voltage realease for air circuit breakers microprocessor based type suitable for existing breakers as per site make / requirement including taking out breakers after taking shutdown of electric supply complete all as specified and as directed.

16

-

-

... More
S&F in repair earth fault realease for air circuit breakers microprocessor based type suitable for existing breakers as per site make / requirement including taking out breakers after taking shutdown of electric supply complete all as specified and as directed.

16

-

-

... More
S&F in repair lockable trip push button for air circuit breakers microprocessor based type suitable for existing breakers as per site make / requirement including taking out breakers after taking shutdown of electric supply complete all as specified and as directed.

16

-

-

... More
S&F in repair Racking padlock assemby for air circuit breakers microprocessor based type suitable for existing breakers as per site make / requirement including taking out breakers after taking shutdown of electric supply complete all as specified and as directed.

16

-

-

... More
S & F in replacement of cylindrical panel locks of suitable size or as per sample including drilling, cutting and welding etc in panel sheets without disturbing to other existing fitments including taking down old one complete all as specified and directed.

20

-

-

... More
Supply, fix, test and commissioning of aluminium enclosure of 3200 Amps ratings, TPN, aluminium sandwich busduct, in repair of IP54, IEC 61439-6, copper contact, dupont mylar insulation class B covered with 2 layers of myler insulation suitable for indoor installation including connection with terminal with all accessores as required complete, copper laminated flexible connections, phase crossover, bends, adopter box, busbar supports, insulating materials all mounting accessories as per site requirement complete. All busbar joints shall have double headed bolt on connection plate, busbar joints shall have colour coded thermal indicator to indicate any excessive temperature rise at joints and other insulating material as per OEM complete all as specified and as directed.

12

-

-

... More
Supply, fix, test and commissioning of aluminium enclosure of 3200 Amps ratings, TPN, aluminium sandwich busduct, in repair of IP54, IEC 61439-6, copper contact, dupont mylar insulation class B covered with 2 layers of myler insulation suitable for outdoor installation including connection with terminal with all accessores as required complete, copper laminated flexible connections, phase crossover, bends, adopter box, busbar supports, insulating materials all mounting accessories as per site requirement complete. All busbar joints shall have double headed bolt on connection plate, busbar joints shall have colour coded thermal indicator to indicate any excessive temperature rise at joints and other insulating material as per OEM complete all as specified and as directed.

12

-

-

... More
Supply, fix, test and commissioning of aluminium enclosure of 2500Amps ratings, TPN, aluminium sandwich busduct, in repair of IP54, IEC 61439-6, copper contact, dupont mylar insulation class B covered with 2 layers of myler insulation suitable for indoor installation including connection with terminal with all accessores as required complete, copper laminated flexible connections, phase crossover, bends, adopter box, busbar supports, insulating materials all mounting accessories as per site requirement complete. All busbar joints shall have double headed bolt on connection plate, busbar joints shall have colour coded thermal indicator to indicate any excessive temperature rise at joints and other insulating material as per OEM complete all as specified and as directed. (NOTE for Ser. Item No. 62.00 to 64.00 above : Old unserviceable sandwitch bus duct obtained shall be contractor's property as per Schedule of Credit.)

12

-

-

... More
M&L for preventive maintenance/testing of 2500 Amps rating TPN aluminium sandwich busduct through OEM (L&T) or OEM authorised dealer only for detection of weak insulation and continuity etc. as per the procedure laid down by OEM complete all as specified and directed. (Note : (a) Testing will be carried out for the whole length of bus duct from Sub station No 1 to AC Plant (b) Dismantling and reassembling of Cable tray required at site shall deemed to be included in the quoted rate.)

1

-

-

... More
All as per Ser. Item No. 65.00 above but 3200 Amps rating TPN aluminium sandwich busduct complete all as specified and as directed.

3

-

-

... More
M&L for bringing Cable testing van (Fault Finder) for detecting the location of fault in the HT UG cable of any size complete all as specified and as directed.

6

-

-

... More
Supply, laying, testing and commissioning of HT cables 22 KV grade (Earthed), XLPE insulated and PVC bedded galvanized steel strip armoured electric power cable (heavy duty) with aluminum conductor, conforming to IS - 7098 Part-II, including removing old unserviceable cable complete of size 185 Sqmm 3 core complete all as specified and as directed.

125

-

-

... More
Supply and fix in repair indoor type HT 22 KV end termination Kit cold shrinkable type suitable for XLPE cable of size 3 core 185 Sqmm by removing burnt / unsv joints from VCB complete all as directed.

3

-

-

... More
Supply and fix in repair outdoor type HT 22 KV end termination Kit cold shrinkable type suitable for XLPE cable of size 3 core 185 Sqmm by removing burnt / unsv joints from transformer complete all as directed.

3

-

-

... More
Supply and fix in repair HT 22 KV straight through jointing Kit cold shrinkable type suitable for XLPE cable of size 3 core 185 Sqmm by removing burnt / old unserviceable complete all as specified and directed.

5

-

-

... More
Material and labour for cutting of existing road/ hard standing by providing suitable T&P to make suitable size bore in road crossing etc. including the cost of making good the disturbed surface and matching with existing (Chequered tiles/Road/ PCC) complete all as specified and directed.

15

-

-

... More
Supply and laying 100 mm bore light grade GI pipe fixed to walls / poles or laid in trenches, road crossing etc, for protection of under ground cable including sealing ends with hessian cloth impregnated with bituminous compound in ground and with suitable clamps, bolt/nuts etc for fixing on walls, poles etc. complete all as specified and directed.

20

-

-

... More
Excavation in trenches in hard/dense soil n exc 1.5m wide and n.exc 1.5m in depth and getting out complete all as specified and directed.

11.25

-

-

... More
Excavation in trenches in soft/dis integrated rock n exc 1.5m wide and n.exc 1.5m in depth and getting out complete all as specified and directed.

7.5

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.

14.75

-

-

... More
Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point where directed complete all as specified and as directed.

4

-

-

... More
Supply and laying 77 mm outer dia, double walled corrugated (DWC) HDPE conforming to IS with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed.

75

-

-

... More
M&L for maintenance free grounding Solution set earthing comprising of 17.2 mm pure copper earthing rod, 3m long, Copper terminal size of 40x6mm with 2 Nos M8 holes for termination. Electrode must be tested for a short circuit test of minimum 40 KA at CPRI/NABL. The earthing electrode will be placed in the ground after a bore is drilled to the depth of 3.5 Mtr. The bore drilling will be done  with the help of a Pneumatic boring machine, 50 Kgs BFC will be placed in the bore to cover the earthing rod from all sides. BFC will be poured in Slurry form in a properly mixed condition. The Earth pit cover Square 300x300x240 mm to be provided to cover the Earth Pit and shall be made of reinforced FRP and should be capable of carrying the weight of 5 Tons. (NOTE :- (a) Rates of boring 3.5 Mtr for earth electrode, Copper strip 25x3 mm upto 7.5 Mtr from earth electrode shall deemed to be included in the quoted rate. (b)  On testing, after completion, if the earth resistance 5 ohms is not obtained, earthing will be rejuvenated at no extra cost to the department till the desired earth resistance is obtained.)

12

-

-

... More
M&L for earth continuity conductor or main earthing lead 32x6mm galvanized iron (GI) strip,fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed.

30

-

-

... More
M&L for earth continuity conductor or main earthing lead 32x6mm Copper strip, fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed.

30

-

-

... More
Supplying and laying synthetic rubber insulated mats 3 mm thick for voltage upto 33 KV (size 2 mtr x 1 mtr) for electrical purpose as per IS 15652-2006 suitable for electrical shock safety complete all as directed. (NOTE : The sample / make of rubber insulated matt shall be got approved from GE by contractor before placing bulk order.)

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.