Military Engineer Services Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date11 Jan 2025
Closing Date6 Feb 2025
Tender Amount₹ 5,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for providing crushed stone dust sand cushioning to UG cable including punning down of sand in layers complete all as specified and directed.

5

-

-

... More
Supply and laying un reinforced precast concrete cable cover class HV, type -1, flat of size 300mm X 180mm X 40mm laid in trenches complete all as specified and directed.

139

-

-

... More
Supply, Laying, connecting & testing of 95 Sqmm 11 KV Earthed HT UG XLPE Insulated cable with aluminum conductor multistranded grade in treches including lugs and cable glands of appropriate size including taking down of old unserviceable HT Cables complete all as specified and as directed

45

-

-

... More
Supply and lay in trenches / along the wall / floor pipes GI light grade of size 100 mm with and including all fittings and accessories complete all as specified and and directed for cable protection complete all as specified and directed

6

-

-

... More
S & F In repairs outdoor Heat shrinkable end termination kit for 11 KV (Earthed) grade cable complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm, including cutting and taking out of unserviceable cable end termination jointing kit complete all as specified and directed

2

-

-

... More
S & F In repairs indoor Heat shrink end termination kit for 11 KV (Earthed) grade cable complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm, including cutting and taking out of unserviceable cable end termination jointing kit complete all as specified and directed

2

-

-

... More
M& L for Disconnecting earthing , Cable of suitable size from falsh over cable termination compartement and foundation bolts or any arrngement for taking out HT VCB, HT 11 KV from LOS/SNCOs mess for Servicing /minor reapir properly cleaning all bushing and carbon spot along with testing of VCB insulation test of intreptors etc, also setting of relay and testing of wiring as per drwing of manufacture all Jointing/ HT contact should be maintain with perteilium jelly and after Servicing, breaker should be reconnected in all respect at Kalina area/LOS/SNCOs Mess, connect the the breaker all as per existing arrangement and restore the power supply complete all as specified and directed .

3

-

-

... More
M& L for repair/replacement of HT VCB 11 KV, VCB Bushing Jaw contract male & Female Finger type and as per site requirment to be repair/repaced duly applied petrolium jalley to avoid the moisture containts from Bushing contact after testing complete all as specified and directed .

6

-

-

... More
M& L for repair/replacement of HT VCB 11 KV, VCB Bushing HTJaw contract male & Female Right Angle Bushing type and as per site requirment to be repair/repaced duly applied petrolium jalley to avoid the moisture containts from Bushing contact contract complete all as specified and directed .

6

-

-

... More
M& L for repair/replacement of HT VCB 11 KV, Heater assembly complete small pocket type and as per site requirment to be repair/repaced duly applied three days test continious to avoid the moisture containts from Bushing contact contract complete all as specified and directed .

6

-

-

... More
M& L for repair/replacement of HT VCB 11 KV, Earth fault relay assembly complete as per site requirment to be repair/repaced duly applied three days test continious to avoid the earth fault to save the equipments life complete all as specified and directed .

1

-

-

... More
M& L for repair/replacement of HT VCB 11 KV, Master relay assembly/MIMIC relay assembly complete as per site requirment to be repair/repaced duly applied three days test continious to avoid the fault to save the equipments life complete all as specified and directed .

1

-

-

... More
M & L for testing of 160KVA 11/.433 KV step down transformer for insulation resistence , Magnetic test and ratio test and trasformer oil for Acidity test and submit the test certifcate after testing complete all as specified and directed. Note: Test of the transformer would be on every six months ( Twice in year).

2

-

-

... More
M & L for testing of 200KVA 11/.433 KV step down transformer for insulation resistence , Magnetic test and ratio test and trasformer oil for Acidity test and submit the test certifcate after testing complete all as specified and directed. Note: Test of the transformer would be on every six months ( Twice in year).

1

-

-

... More
M & L for testing of 250KVA 11/.433 KV step down transformer for insulation resistence , Magnetic test and ratio test and trasformer oil for Acidity test and submit the test certifcate after testing complete all as specified and directed. Note: Test of the transformer would be on every six months ( Twice in year).

2

-

-

... More
M & L for testing of 500KVA 11/.433 KV step down transformer for insulation resistence , Magnetic test and ratio test and trasformer oil for Acidity test and submit the test certifcate after testing complete all as specified and directed. Note: Test of the transformer would be on every six months ( Twice in year).

1

-

-

... More
Equipment labour for filtration of transformer oil as in topping up by filtartion plant to remove moistrure and carbon contentents to achive dielectric strength of oil up to 50KV in 4mm gap and producing test result on recordes before and after filtartion and including Disconnecting the HT and LT cables and cleaning the bus bar surfaces and reconnecting the cables by providing copper washers, bolts, nuts etc all as dirctected by Engineer in Charge Note - (a) Oil required for topping up while for filtaration will issued under respective item of Sch A . (b) Filtration of the transformer would be on every six months ( Twice in year).

950

-

-

... More
Supply only transformer oil to be incorporated in item No 21 above IS -335 and all as directed by Engineer in Charge

200

-

-

... More
M & L For taking out unserviceable LV bushings and replacing LV Bushings with copper/brass stud complete with rubber gasket, brass bolts, brass nuts all for 11KV/0.433 KV transformer of rating upto 100 KVA to 500 KVA complete all as specified and directed

4

-

-

... More
M & L For taking out unserviceable HV 11 KV bushings and replacing HV 11 KV Bushings with copper/brass stud complete with rubber gasket, brass bolts, brass nuts all for 11KV/0.433 KV transformer of rating upto 100 KVA to 500 KVA complete all as specified and directed

3

-

-

... More
Supply & Fix in Replacement Silica Gel Breather with silica gel for 11 KV Transformer of Rating from 160 KVA to 500 KVA complete all as specified and directed

3

-

-

... More
Disconnecting the existing HT/LT cable from transformer terminal and taking down Transformer of 100KVA to 500 KVA capacity from position and shift to new location on pole/ PCC platformfor the maint/relocation/maint of sub station etc including reconnection of existing HT/LT cable connection incl transportation distance not Exc 2500 meters of capacity up to 500 KVA complete all as specified and directed

1

-

-

... More
M&L for & rewinding of HT coil with same gauge & same material of exsisting coil with similar class of exsisting insulation all as specified & directed.

80

-

-

... More
M&L for removing the LT coil from core carefully & re-insulation of LT coil with same class of insulation all as specified & directed .

65

-

-

... More
M& L for disconnecting carefully electrical connection from HT/LT sides of the transformer keeping them at safe side and taking out the transformer indoor type 100 to500 KVA,11 / .433KV step down/step up any make carrying out complete overhauling which shall complete of the following :- (a) M & L for lifting transporting handling,the transformer to workshop and opening top cover of the transformer by unscrewing nuts, bolts,washers etc including disconnecting core assy from HT/LT bushing and lifting the same gently and taking out from the shell (container/body) of the transformer. (b) M&L for draining out transformer oil from the above said transformer in the suitable capacity of container/drums and keeping it in safe custody for reuse. (c) M&L for cleaning of the transformer body from inside, removing deposited dirt/sludge/foreign particles etc from the bottom/body of the transformer and drying/heating up the shell from inside before refilling of the transformer oil. (d) Cleaning/washing through core and windings of the tansformer by housing down with clean dry oil conforming IS 335/983,removing deposited dirt sludge/foreign particles from the windings/core and revarnishing of the windings with super varnish including heating/drying/packing complete carefully and throughly inside the heating chamber at suitable temperature to obtained required value of insulation resistance etc all as per IS and directed by Engr-in-charge

1

-

-

... More
(e) Lifting and refixing core assy inside the transformer shell gently and carefully,connecting of HT/LT/Neutral connections to the bushings assy,fixing of the tap change over incl tightenting of nut,bolts,washers of the core to reduce humming noise all as directed. (f) Refilling the transformer oil in the shall of transformer only after carrying out filteration by heating upto oil 105 degree certigrade to active reqd dielectric strength and submitting the test result before and after filteration of oil all as specified & directed . (g) Refixing the top cover incl replacement of corck sheet/gasket ,tightenting of nut bolt,washers etc all as directed. (h) Lifting/shifting to the place from where removed and reinstalling the transformer including connecting HT/LT/Neutral/Earthing connections etc all as directed. Note:- (i) Any damage to insulator/bushes/windings etc while in the custody of the contractor shall be made good at no extra cost to govt.The serviceability of the transformer shall be checked and confirmed by the contractor before taking into his custody. (ii) The job taken for repair/overhauling should be complete with in 15 days from the date of handing over the individual transformer,failing which necessary arrangement to be made by the contractor at no extra cost. (iii) Rewinding / re-insulation of winding of HT/LT coil will be paid seperately under relavant item of sch.

-

-

-

... More
Ditto all as per Ser Item No. 28.00 above but 11/0.433KV OCB complete all as specified and directed

1

-

-

... More
Supply and fixing earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn into conduit/pipe or fixed to poles or any indicated situation for loop earthing etc copper strip 20mmx3mm and includidng taking out unserviceable copper strip of any sizes complete all as specified and directed

45

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.