Military Engineer Services Tender
... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Eprocure
Opening Date21 Feb 2025
Closing Date13 Mar 2025
Tender Amount₹ 32,00,000
Costs
EMD
₹ 64,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_698917_1Tender No
GE I R AND D GNR TOKEN 62 OF 2024 2025Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Material and labour for cutting of bituminous road / floor for laying of pipe / cables 45 CM wide and not exceeding 1.5 meter deep including refilling / with material and watering well ramming / compacting and making good with PCC 1;2;4, type B-1, 100 mm thick complete all as specified and directed.
20
-
-
... More
Supply & Laying 50 mm outside dia double wall corrugated pipe (DWC) of HDPE ISI Mark for enclosing cable below ground / road surface, to a required depth, including suitable size coplers for jointing of pipe all as per site requirement complete all as specified and directed.
870
-
-
... More
Supply & Laying 75 mm outside dia double wall corrugated pipe (DWC) of HDPE ISI Mark for enclosing cable below ground / road surface, to a required depth, including suitable size coplers for jointing of pipe all as per site requirement complete all as specified and directed.
50
-
-
... More
Boring of road for cable crossing, 60 cm below the road horizontally including all arrangement of T&P and necessary excavation etc complete all as specified and directed.
Note :- GI pipe will be measured and paid separately.
20
-
-
... More
M&L for replacement of existing unserviceable silica jel with new crystal clear silica jel for breather of transformer complete all as specified and directed.
20
-
-
... More
M &L for GI pipe light grade in repair for road crossing / on wall / on pole for cable protection of following size:-
a) 50 mm dia
30
-
-
... More
b) 80 mm dia
20
-
-
... More
c) 100 mm dia
10
-
-
... More
M & L to find out fault in LT line bring/call fault finding machine equipment and find out fault in any size of LT UG Cable including disconnecting of cable connection from both side panels/poles and necessary excavation in any type of strata to reach upto cable and making space for cable joint all as directed.
Note:- (i) Cable required at site same size of faulty cable if required for jointing purpose will be paid in relevant item. (ii) Jointing material will be paid in relevant Item.
15
-
-
... More
M & L to find out fault in HT line bring/call fault finding machine equipment and find out fault in any size HT UG Cable including disconnecting of cable connection from both side panels/poles and necessary excavation in any type of strata to reach upto cable and making space for cable joint all as directed. Note:- (i) Cable required at site same size of faulty cable if required for jointing purpose will be paid in relevant item. (ii) Jointing material will be paid in relevant Item.
5
-
-
... More
Supply and jointing straight through joint, 11000 volts grade heat shirnkable type suitable for 3 core, 95 Sqmm to 120 Sqmm HT, XLPE cable and testing after jointing all as specified and directed by Engr-in-charge.
1
-
-
... More
Supply and fix in repair straight through cable jointing kit 22 KV earthed grade heat shrinkable joint with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm complete all as specified and directed.
2
-
-
... More
Material and labour for dismantling old cable end termination and supply and jointing new Cable end termination heat shrinkable outdoor type suitable for 22KV, 185 sqmm XLPE, 3 Core power cable with aluminium conductor complete all as specified and directed.
3
-
-
... More
M & L for cable jointing kit for 22 KV earthed graded cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm complete all as specified and directed.
2
-
-
... More
Taking down the existing defective HT UG cable of following size in trenches / pipes / pole for attending the repair, jointing materials, refixing / relaying back in trenches fixed on poles complete all as specified and directed. (a) upto 185 sqmm 3 core. Note-: (i) Excavation and earth work will be measured and paid seperately under relevant item. (ii) Old U/S cable shall be the property of contractor and will be measured in Sch of credit.
25
-
-
... More
Supply and laying HT UG Cable of size 185 sqmm 3 core heavy duty 22000 volts grade with aluminium conductor strip armoured PVC insulated and XLPE sheathed incl jointing material etc. Laid in trenches / ducts / fixed on wall / pole or drawn through pipes complete all as specified and directed.
45
-
-
... More
Taking down the existing defective LT UG cable of following size in trenches / pipes / pole for fault finding /attending the repair and repair the same all as specified and directed .
(a) 6 sq mm 2/3/3.5/4 core upto 50 sqmm 3/3.5/4 core.
200
-
-
... More
(b) 95 sq mm x3.5 core upto 185 x3.5 core sqmm.
Note for item No.18.00 (a) & 18.01 (b) above : (i) Cost of excavation & earth work shall deemed to be included in quoted rate. (ii) If the existing cable become faulty and can not be useful, then cable/joint kit shall be provided by contractor as supply and fix under relavant item. Retrived cable shall be handed over to contractor as per Schedule of credit.
80
-
-
... More
Supply & fix heat srinkable jointing kit for 1.1 KV grade cable for straight through joint/ end joint kit complete with jointing material and accessories suitable for 2/3.5/4 core XLPE / PVC armoured AIuminium Conductor cable of following size all as directed by EIC.
(a) 16 sqmm to 35 sq mm
8
-
-
... More
(b) 50 sqmm to 70 sq mm
6
-
-
... More
(c) 70 sqmm to 95 sq mm
5
-
-
... More
(d) 120 sqmm to 185 sq mm
5
-
-
... More
Supply and lay LT PVC/XLPE insulated, armoured, heavy duty under ground electric cable with aluminium conductor, 1100 volts grade of following cross-sectional area including cable lugs, jointing materials etc., laid in trenches fixed on poles or laid through GI pipes including taking down old unserviciable cable all as specified & directed. Note: (i) Excavation and earth work will be measured and paid seperately under relevant item. (ii) Old U/S cable shall be the property of contractor and will be measured as in Sch of credit.
(a) 2 core 10 sq. mm
150
-
-
... More
(b) 4 core 10 sq. mm
180
-
-
... More
(c)4 core 16 sq. mm
150
-
-
... More
(d) 3.5 Core sec. area 25 sq. mm
150
-
-
... More
(e) 3.5 Core sec. area 35 sq. mm
130
-
-
... More
(f ) 3.5 Core sec area 50 sq. mm
110
-
-
... More
(g) 3.5 Core sec. area 95 sq. mm
80
-
-
... More
Servicing the 22 KV GOD by cleaning the contact, disc/pin insulator with CTC & applying the petrolium jelly at the contact point/down rod links for smooth operation including replacing the rusted/corroded bolts & nuts and defective insulator of GOD as required at site. Note :- Insulator shall be measured and paid under relavant items.
2
-
-
... More
Servicing the 11 KV GOD by cleaning the contact, disc/pin insulator with CTC & applying the petrolium jelly at the contact point/down rod links for smooth operation including replacing the rusted/corroded bolts & nuts and defective insulator of GOD as required at site. Note :- Insulator shall be measured and paid under relavant items.
2
-
-
... More
a) Male / Moving contact ( set of 3 Nos )
2
-
-
... More
b) Female / Fixed contact ( set of 3 Nos )
2
-
-
... More
c) Copper tinned strip ( set of 3 Nos )
2
-
-
... More
Supply and fixing ABB CEF tranformer fuses for 22 KV RMU all as specified and directed.
5
-
-
... More
Material and labour for dismantling old U/S AB switch and Supply, installation. connecting electrically & commissioning switch air break, gang operated, tripple pole mounted on insulators 15 Nos with drop out fuse and steel frame with operating mechanism in working from ground level, including jumper connection with ACSR conductor alongwith PVC pipe covering with colour code between main supply and GOD complete all as specified and directed for current rating upto 400 amps and working voltage 22000 volts all as required at site or directed by Engr-in-charge.
1
-
-
... More
Material and labour for dismantling old U/S AB switch and Supply, installation. connecting electrically & commissioning switch air break, gang operated, tripple pole mounted on insulators 15 Nos with drop out fuse and steel frame with operating mechanism in working from ground level, including jumper connection with ACSR conductor alongwith PVC pipe covering with colour code between main supply and GOD complete all as specified and directed for current rating upto 400 amps and working voltage 11000 volts all as required at site or directed by Engr-in-charge.
1
-
-
... More
Cutting / trimning of Tree branches which are touching to HT / LT over head lines and clearing the same up to 4 meter radius for span length not exceeding 45 to 55 meter complete all as specified and as directed by Engineer - in - Charge. Note: Each span of 45-55 Mtrs will be considered as one length of span for payment purpose
10
-
-
... More
M & L for painting of steel tubular LT pole up to 9 mtr long with two coats of aluminium paint incl cross arms (for single pole), clamps etc complete including marking of pole No with black paint with all arrangement for ladder etc all as specified and directed.
98
-
-
... More
Isolate/de-energize the supply to the HT/LT Panel Board of capacity ranging from 200 Amps to 2000 Amps, opening the doors/covers of the cubicle enclosure for carrying out the servicing/ maintenance/ repairs of the Panel Board, switch gear, metering etc and re-fixing the same in place after repairs including testing and commissioning of the panel board comprising of the following:-
a) Cleaning the inside switch gear chambers for removing dust, carbon and rusted surfaces including cleaning with blower and apply insulating varnish.
b) Check the condition of the DMC/SMC support insulators including cleaning applying Dr beck red for better IR values and replacement of insulators if required. c) Tightening up of all bus bar connections, cable connections, replace bolt, nuts wherever required.
Note : Contractor has to inspect the site before quoting. Any modifications/frame work and renewal is deemed to be included in the quoted rates. Spares will be measured and paid under relevant items of schedule
8
-
-
... More
S&F in repair mild steel hinges suitable for LT panel board shutters including welding, riveting complete all as specified and directed.
8
-
-
... More
Disconnecting and taking out old existing worn out control wiring connections including cable lugs of LT panel board of 4 wire system and supply and connect with new cable PVC insulated, stranded copper conductor 2.5 sqmm including with new copper lugs and nuts, bolts, washers complete all as specified and directed.
10
-
-
... More
Disconnecting and taking out old existing worn out cable lugs, nuts, bolts, washers etc from LT panel board of 4 wire system (incomming and outgoing) and supply and connect with new aluminium lugs all sizes as per site requirement and nuts, bolts, washers etc complete all as specified and directed.
10
-
-
... More
Material and labour for dismantling of old steel tubular pole and suppy, errecting in truly vertical position steel tubular swaged pole 9.0 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 31, including painting with anti corrosive paint internally complete and externally up to planting depth, alternative white & black strips of 30 cm width upto 1.5 mtr above ground level all as required at site.
2
-
-
... More
Surface excavation not exceding 30 cm deep in hard dense soil and averaging 15 cm deep and getting out green vegetation, roots, bushes, etc surrounding of 2 / 4 pole structure / substations / RMU all as directed by Engr-in- charge.
150
-
-
... More
M&L for PCC 1:4:8 Type D2 using 40 mm graded aggregate in foundation including form work and finishing the exposed surface of concrete even and smooth complete all as specified and directed.
1.94
-
-
... More
M&L for providing PCC 1:2:4 type B-1 with 20 mm graded aggregate for coping of pole including necessary formwork complete all as specified and directed.
1
-
-
... More
S& F in replacement of MCCB 3 Pole 63 Amps 16 kA Thermal magnetic adjustable type & should be Ics=Icu=100% with both side spreader links all as specified and directed.
4
-
-
... More
S& F in replacement of MCCB 3 Pole 100 Amps 16 kA Thermal magnetic adjustable type & should be Ics=Icu=100% with both side spreader links all as specified and directed.
4
-
-
... More
S& F in replacement of MCCB 4 Pole 160 Amps 25 kA Thermal magnetic adjustable type & should be Ics=Icu=100% with both side spreader links all as specified and directed.
3
-
-
... More
S& F in replacement of MCCB 4 Pole 200 Amps 25 kA Thermal magnetic adjustable type & should be Ics=Icu=100% with both side spreader links all as specified and directed.
3
-
-
... More
S& F in replacement of MCCB 4 Pole 250 Amps 25 kA Thermal magnetic adjustable type & should be Ics=Icu=100% with both side spreader links all as specified and directed.
2
-
-
... More
S& F in replacement of MCCB 4 Pole 400 Amps 36 kA Thermal magnetic adjustable type & should be Ics=Icu=100% with both side spreader links all as specified and directed.
1
-
-
... More
S & F in replacement of ACB type manual fixed with microprocessor based LSIG & tempreture rise protection consisting of digital display with battery backup 3 ph ,4 pole, 415 Volts, 630 Ampr 50KA in existing panel & connecting to incoming & outgoing with suitable rating of Aluminium/Copper busbar properly testing of ACB all as specified and directed.
1
-
-
... More
M&L for Servicing to outdoor type panel board of size 1.50x0.65x1.90m double door with canopy by (i) Cleaning with blower, (ii) Cleaning with CTC/Petrol (iii) Replacement of damaged lugsif any (iv) Replacement of deteriorated copper wiring (v) Cleaning and tightening of MCCB terminal connections (vi) Replacement of sheared rubber beadings (vii) Rectifying of loose connections (viii) Replacement of door shutters of size 1.75mx0.75 m ,with 3.15mm thick CRCA sheet incl locking arrangement , door hinges- 2 nos . (ix) painting of LT panel with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer including preparing old surfaces at site & writing feeder name with white paint on all incoming and outgoing feeders (x) Painting of angle iron base frame of size 1.50mx0.65m with 4 legs 30 cm long with black paint all as shown & directed.
3
-
-
... More
M&L for writing letters or figures (Block, Roman, Italic or Indian) of 4cm to 15cm height at E/M installations.
4
-
-
... More
Supply, install, connect & testing cubical outdoor type factory made double door , powder coated LT bus bar feeder pillar box for 100 amps 3ph and neutral arrangement of size 500mmx500mmx200mm complete weather proof and verminproof conforming to IP-54 made out of 3.2mm thick CRCA sheet including provisions for ventilation and cable termination alley all as per IS. It should be mounted on 40 x40 x 6mm angle frame with a clearance of at least 0.45 mtrs above GL and 0.30 mtrs below ground including required PCC for foundation and coping complete all as specified and directed.
1
-
-
... More
Supply, install, connect & testing cubical outdoor type factory made double door, powder coated LT bus bar feeder pillar box for 200 amps 3ph and neutral arrangement of size 500mmx500mmx200mm complete weather proof and verminproof conforming to IP-54 made out of 3.2 mm thick CRCA sheet including provisions for ventilation and cable termination alley all as per IS. It should be mounted on 40 x40 x 6mm angle frame with a clearance of at least 0.45 mtrs above GL and 0.30 mtrs below ground including required PCC for foundation and coping complete all as specified and directed.
1
-
-
... More
Material and labour for dismantling U/S 25x3 mm earthing strip and supply and fixing of earthing strip with 25x3 mm aluminium strip fixed on wall floor pole for earthing of GOD, lightning arrestor etc incl drilling holes in any position, connection, nut bolts etc complete all as specified and directed.
35
-
-
... More
Material and labour for dismantling U/S 20x3 mm copper earthing strip and supply and fixing of earthing strip with 20x3 mm copper strip fixed on wall floor pole etc incl drilling holes in any position, connection, nut bolts etc complete all as specified and directed.
25
-
-
... More
Material and labour for dismantling U/S 32x6 mm earthing strip and supply and fixing of earthing strip with 32x6 mm GI strip fixed on wall floor pole for earthing of GOD, lightning arrestor etc incl drilling holes in any position, connection, nut bolts etc complete all as specified and directed.
50
-
-
... More
S&F in replacment of 3 phase digital multi function meter with suitable accessories and fixing arrangements.
4
-
-
... More
S&F in replacement of selector switch suitable for 415 volts.
8
-
-
... More
S&F in replacment of voltmeter/Ammeter of range 0 to 500 Volts.
8
-
-
... More
S&F in replacament of LED type phase indicator to be fitted on panel ( R,Y, B as per site requirement)
20
-
-
... More
M&L for dismentling and disconnecting the ACB rating 800/630 amps Make: Crompton greaves/ C&S/ L&T by carrying out repairs/ servicing, checking and renewing the defective shunt trip coil & UV trip 415 volts AC, checking and rectifying the defective CTs and rectifying the mechanism operation including spring charging system, reinstalling the same in the panel and providing necessary line and connections complete all as directed by Engineer-in-charge
2
-
-
... More
Material and labour for dismantling of old danger notice plate and supply and fixing danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts & nuts of approved size of 20 x 15 cm size.
28
-
-
... More
M & L for Scraping of old paint from two pole structure without removing accessories and preparation of surfaces for repainting. painting of 4 pole structure with two coats of aluminium paint incl channels, DO fuse parts, clamps etc complete including marking of pole No with black paint with all arrangement for ladder and painting of bottom portion of the pole upto 1.0 m from top of the copping with one coat of synthetic enamel red paint over a coat of red oxide primer etc all as specified and directed.
3
-
-
... More
Supply & fix HT fuse element 22 KV fibre glass type suitable for folloiwng :- (Make EADC/Equivalent/vidhut)
(a) 22 KV 20 to 60 Amps
15
-
-
... More
Disconnecting all the electrical connections from H.T.and L.T. side of unserviceable transformer of cap above 160 KVA to 500 KVA i.e. Jumpers/cable from the cable end box or bushings & earthing terminal of the transformers, loading and unloading of transformer & transportation by vehicle from substation to the repairing workshop including reinstallation, commissioning and testing complete.
3
-
-
... More
Opening the transformer cover along with the conservator by removing the nut bolts then after removing the internal HT & LT connections by taking them out by removing studs, bushings, taking out the core-winding assembly out of the tank removing out burnt HV and LV windings from the core assembly,Draining & decanting of burnt transformer oil and cleaning of sludge deposited in the tank with CTC of transformer having ratio 22/0.433 KV . Rewinding of HV and LV coils with suitable size super enamelled copper wire / strip ( As Existing ) having suitable class insulation material . Heating of core winding assembly in hot chamber for 48 hours and remove all the moisture present in it , removal of leakage of tank if any by welding, refilling transformer oil to tank , after putting the core-winding assembly into the tank, reassembling making the internal H.T. & L.T. connections by fixing the studs, bushings,fitting the top cover by replacing cork sheet gasket along with conservator, testing the transformer in the workshop, all as directed by Engineer-in-charge.for various capacities as under :-
a) upto 160KVA
2
-
-
... More
b) All as per item herein above but 160KVA to 500 KVA
2
-
-
... More
Supply and fix super enamelled copper winding wire / strip of any size for H.T coils of transformers
50
-
-
... More
Supply and fix copper winding wire/ strip of any size for L.T. coils of transformers including providing insulation all as required.
45
-
-
... More
Reconditioning of LT coil of copper wound transformer by turning the old paper insulations, straightening the entire LT Strip providing new paper insulations of superior quality and making coil of suitable design as original all as specified and directed by Engr-in-Charge.
30
-
-
... More
Supply & fix HT Bushing (as per sample)
3
-
-
... More
Supply & fix LT Bushing (as per sample)
3
-
-
... More
Supply & fix brass stud (for LT433V side)of suitable size complete with one chuck nut, two nuts, washers and rubber seal, all as per sample for outdoor type transformer of the capacity as under:-
a) upto 160 KVA
3
-
-
... More
b) All as per item herein above but 160KVA upto 250KVA
3
-
-
... More
c) All as per item herein above but 250KVA upto 500KVA
3
-
-
... More
Supply & fix brass stud (for HT 22KV side) of suitable size complete with one chuck nut, two nuts, washers and rubber seal, all as per sample for outdoor type transformer of the capacity as under:-
a) upto 160KVA
3
-
-
... More
b) All as per item herein above but 160KVA upto 250KVA
3
-
-
... More
c) All as per itemherein above but 250KVA upto 500KVA
3
-
-
... More
Scrubbing of old rusted paint from transformer and preparation of surfaces for fresh painting, by means of spray painting with two coats of synthetic enamel paint of approved colour of transformer up capacity 100 KVA to 500 KVA and writing SM No/MES No of the transformer etc complete all as specified and as directed.
6
-
-
... More
M&L for dehydration of transformer oil with mobile transformer oil filtration plant at site with all accessaries connected to transformer and carrying out filteration of oil for desired dielectric strength i.e. not less than 40 KV at 2.5mm gap.
Note :- 1. Test certificates shall be submitted before and after filteration for dielectric strength on the proper format .
5600
-
-
... More
M & L for replacement of breather assembly of transparent plastic body with top and bottom portion pressed with metalic cover, filled with silica jel blue in colour and suitable for pipe entry of 15/20/25mm dia as per the site requirement, complete all as specified and as directed by Engineer-in-Charge.
7
-
-
... More
Supply and Filling/ topping up new transformer oil of approved make conforming to IS- 335 / 1983 including testing of IR value of the oil not less than 60 KV, complete all as specifaied and as directed by Engineer - in - charge.
1050
-
-
... More
M&L for taking down transformer oil level indicator assembly of transformer upto 500 KVA capacity from position for making visibility of oil level by lowering oil level in conservator including cleaning thoroughly, painting, changing of gaskets and acrylic sheet, fixing back in position refilling the removed oil.
8
-
-
... More
M&L for earth testing, identifying the earthings in system and recording the results on indicator board and producing three copies of test sheet duly signed by Contractor all as directed by Eng-in-charge.
Note :- (i) Cost of labour and tools required for testing is deemed to be included in quoted rates.
20
-
-
... More
M & L for repair to earth chamber by providing plastering to existing earth chamber including provision of new earth chamber cover of specified size and marking the earth pit number, complete all as specified and as directed by Engineer-in-charge.
12
-
-
... More
M&L in replacement of earth pit indicator board made out of MS sheet 6mm thick of size 25cm x 15cm fixed on MS flat of size 40 x 6mm x 1.2mtr (long) by means of nut, bolt/ welding duly painted with two coats of synthetic enamel paint over a coat of red oxide paint of approved colour including writing the letters of size not exceeding 60mm all as directed by Engineer - in - charge. The indicator should indicate the following :- (i) Earth Pit No. (ii) Earth result in Ohms (iii) Date of testing
Note :- (i) Cost of excavation of earth in any type of soil/ rock for erection of earth pit indicator board removal (upto the 50 Mtrs from starting point) and returning filling in of soil/ rock is deemed to be included in the quoted rates.
12
-
-
... More
M&L in repairs of GI funnels with wire mesh for earthing complete all as specified and as directed by Engineer-in-charge.
16
-
-
... More
S&F on wall/pole FP on load changeover switch in sheet steel enclosure including dismentaling of existing changover of capacity 200 amp with staggered terminals and inbuilt cable gland box etc.
1
-
-
... More
S&F on wall/pole FP on load changeover switch in sheet steel enclosure including dismentaling of existing changover of capacity 400 amp with staggered terminals and inbuilt cable gland box etc.
1
-
-
... More
Supply and Fix aluminium lugs of size 16 Sqmm
20
-
-
... More
Supply and fix aluminium lugs of size 25 Sqmm
20
-
-
... More
Supply and fix aluminium lugs of size 35 Sqmm
20
-
-
... More
Supply and fix aluminium lugs of size 50 Sqmm
20
-
-
... More
Supply and fix aluminium lugs of size 70 Sqmm
20
-
-
... More
Supply and fix aluminium lugs of size 95 Sqmm
20
-
-
... More
Supply and fix aluminium lugs of size 120 Sqmm
15
-
-
... More
Supply and fix aluminium lugs of size 150 Sqmm
15
-
-
... More
Supply and fix aluminium lugs of size 185 Sqmm
10
-
-
... More
M&L for earthing with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25M deep below ground level with top edge of the plate not less than 1.5M below normal ground level connected to galvanised strip 32x6mm by means of nuts, bolts, checknuts, washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I connected to earthing test point including excavation/ earth work in any strata removal of surplus earth, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 in cover slab with 40mm dia light grade GI protection pipe and 20mm dia light grade GI pipe for watering all as specified and directed by Eng-in-charge.
Note : Earth lead strip upto 7.5m is included in quoted rate.
4
-
-
... More
M&L for earthing with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25M deep below ground level with top edge of the plate not less than 1.5M below normal ground level connected to GI Earth wire 4 mm by means of nuts, bolts, checknuts, washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I connected to earthing test point including excavation/ earth work in any strata removal of surplus earth, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 in cover slab with 40mm dia light grade GI protection pipe and 20mm dia light grade GI pipe for watering all as specified and directed by Eng-in-charge.
Note : Earth lead wire upto 7.5m is included in quoted rate.
6
-
-
... More
M&L for earthing with copper plate electrode 600x600x3.15mm thick buried directly in ground earth pit not less than 2.25M deep below ground level with top edge of the plate not less than 1.5M below normal ground level connected to copper strip 20x3 mm by means of nuts, bolts, checknuts, washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I connected to earthing test point including excavation/ earth work in any strata removal of surplus earth, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 in cover slab with 40mm dia light grade GI protection pipe and 20mm dia light grade GI pipe for watering all as specified and directed by Eng-in-charge.
Note : Earth lead strip upto 7.5m is included in quoted rate.
3
-
-
... More
M&L for hard core of broken stone or boulders of gauge n. exc. 40 mm, deposited, spread and leveled in layers n. exc. 200 cm thick, watered and rammed to a true surface.
16
-
-
... More
S&F in replacement of timer switch 16 Amps, 230 Volts, 24 hrs dial type for operation with by pass operation.
6
-
-
... More
S&F in replacement of triple pole power contactor suitable for 40 Amps, with coil voltage 230 Volts.
6
-
-
... More
Supply and fix outdoor type FRP junction box light weight suitable for pole mounting includin flat iron clamp duly painted with two coats of aluminium paint over a coat of red oxide primer and GI nut, bolts, washers and necessary connector for loop in loop out cable connection and suitable size galnds, of size 250x200x105 mm.
25
-
-
... More
Supply and fix inreplacement of 3 x 1.5 sq mm PVC Circular copper cable for connection of street light fitting, Security light fitting, post top lantern and garden light fitting and including all fixing arrengenment with proper fixing all as directed by Engr in charge.
100
-
-
... More
Dismentling and taking down existing any type (Street light) fitting fixed on bldgs/poles /wall.
40
-
-
... More
S & Fix LED Street light fitting 90 Watts High performance IP 66 protection and impact resistance of IK07 LED street light luminaires with complete acessories all as specified and directed by Engr In charge .
25
-
-
... More
S & Fix LED Street light fitting 60 Watts High performance IP 66 protection and impact resistance of IK07 LED street light luminaires with complete acessories all as specified and directed by Engr In charge.
25
-
-
... More
Supply & fix LED 35W decorative post top lantern for 360 degree indirect light, made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection, resistance to impact and corrosion, glare free and better uniformity all as specified and directed
4
-
-
... More
Supply and fix electronic driver for LED street light fitting as per sample/existing fitting specifications complete with all accessories as suitalable for street light fitting of size 90 Watt. Note- Quoted rate include replacement of driver and testing and making fitting serviceable and upto JE/Engr-in-Charge satisfaction.
30
-
-
... More
Supply and fix electronic driver for LED street light fitting as per sample/existing fitting specifications complete with all accessories as suitalable for street light fitting of size 60 Watt.
Note- Quoted rate include replacement of driver and testing and making fitting serviceable and upto JE/Engr-in-Charge satisfaction.
50
-
-
... More
Supply and fix electronic driver for LED street light fitting as per sample/existing fitting specifications complete with all accessories as suitalable for street light fitting of size 30/45 Watt
Note- Quoted rate include replacement of driver and testing and making fitting serviceable and upto JE/Engr-in-Charge satisfaction.
40
-
-
... More
Supply and fixing in replacement of existing unserviceable HPSV/metal hallied lamp fitting of any wattage on existing pole with LED flood light fitting 300 watts with secondary optics made in pressure dia cast housing with heat sink and aluminium extrusion with IP66 with necessary braket ,clamps duly painted with two coats of aluminium paint over a coat of red oxide primer the quoted rate includes 7.5 mtr 3 core 6 Sqmm PVC copper cable with PVC conduit for connection, incl. bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed by Engineer-in-charge.
4
-
-
... More
supply and Fixing fire shape indutries galvanized -Iron safety fire buket (9L Red) for fire place complete all as specified and directed by Engr-in-charge.
3
-
-
... More
Supply and Fix fire Beater and Fire Hook made by metal with wooden hadle Length (3.5M) at fire point complete all as specified and directed by Engr-in-charge.
2
-
-
... More
M& L for VCB Cleaning, Greasing mechanism, Old greasing cleaning, Checked Electrical Motor, Checked & tight control connection, Checked Charging Mechanism, Greasing Moving part and mechanism, Checked Electrical Motor, Checked HT Cable Connection, Checked Boots, Earth Switch ON OFF Operation, Checked shunt coil, Checked Functions of relay Electric Make Relay Testing:
Overload Current, Short circuit Ground Fault, CT R Phase, Y Phase CT, B Phase CT, Control Wiring Checking
VCB Panel Heater Installation (Per Panel 2 heaters 200Watt) :
Control Wiring, MCB serviceable and upto JE/Engr-in-Charge satisfaction.
1
-
-
... More
Supply only spares for VCB.
(a) HT Tape
4
-
-
... More
(b) Relay suitable for HT VCB panel complete all as specified and directed. make schneider
2
-
-
... More
(c) Tripping coil
3
-
-
... More
(d) CT suitable for HT VCB panel complete all as specified and directed.
4
-
-
... More
(g) Relay batteries
8
-
-
... More
(h) Power Pact 24 V DC
1
-
-
... More
Supply and fixing of cable route marker for LT Cable made out of CI, 8 inch of length and 4 inch dia painted with yellow colour including pcc work complete all as specified and directed by Engr-in-charge.
20
-
-
... More
Supply and fixing of Fire Extinguisher CO2 type fire extinguisher of capacity 4.5 kg made from brand new seamless cylinder fitted with discharge hose and horn and squeeze grip type valve with initial charge. Make : Safex/Rainx
4
-
-
... More
Supply and fixing of cable route marker for HT Cable made out of CI, 8 inch of length and 4 inch dia painted with yellow colour including pcc complete all as specified and directed by Engr-in-charge.
30
-
-
... More
Dismantling the old unserviceable LT Panel Board and Supply Fabricate, install, connect, test and commission outdoor type dust & Vermin proof LT electrical panel board, 1100 volts, 50 Hz AC supply, fully compartmentalised for cable chamber and busbar chambers with adequate space made out of 3 mm thick CRCA sheet epoxy powder coating for like all surfaces in and out and internal chambers made out of 2 mm thick sheet including double side opening hindged doors with gasket and suitable angle iron/ flat iron frame work/ supports bottom 50x50x6 mm MS channel as base and chamber for metering equipment complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated and connection wirings with FRLS copper conductor complete mounted on PCC pillars foundation, cable connection using new lugs complete with danger notice all as specified and comprising of the followings:-
Note: (i) Existing cables which removed from old panel board will be fixed with new lugs during fixing in new panel board (if required) (ii) Getting of approval for Panel board drawing from Engr-in-Charge is necessary before fabrication. (iii) All swith gears should be fixed with 06 mm thick Fibre sheet Make: MES & CPRI approved make
(iv) All MCCBs fixed with extended rotary handles ROM
(v) Adequate space and independent compartment given to MCCBs & switch gears as directed
(vi) Adequate space given to Each MCBs for easy cable connection and working :-
a) LED/Neon indicator bulb in RYB Colour - 1 Set.
b) 4 No aluminium Bus bar 200 amps with chamber.
c) Digital Multi function meter for showing Amps (upto 500 Amps) and Voltage (upto 500 voltage) with suitable CT and PT.
d) MCCB 4 Pole, 415 V, Adjustable thermal & adjustable magnetic type, 200 A with breaking capacity 25 KA - 01Nos
e) MCCB 4 Pole, 415 V,adjustable type, 100 A with breaking capacity 16 KA - 02 Nos
f) MCCB 4 Pole, 415 V,adjustable type, 63 A with breaking capacity 16 KA - 02 Nos
g) MCB 4 Pole, 415 V,adjustable type,40A - 02 Nos
h) suitable cable gland for incoming and outgoing cable
1
-
-
... More
Supply & Laying synthetic rubber insulated mat 3mm thick for voltage up to 1.1 KV for electric shock safety of size 2X1m. complete all as specified and as directed.
2
-
-
... More
Supply & Laying synthetic rubber insulated mat 3mm thick for voltage 22 KV for electric shock safety of size 2X1m. complete all as specified and as directed.
2
-
-
... More
Material and labour for dismantling of old steel tubular pole and suppy, errecting in truly vertical position steel tubular swaged pole 8.5 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 22, including painting with anti corrosive paint internally complete and externally up to planting depth, alternative white & black strips of 30 cm width upto 1.5 mtr above ground level all as required at site.
2
-
-
... More
Supply & fix cylindrical capacitors for following sizes as per existing capacitor bank panel including all fixing arrengenment with proper fixing all as directed by Engr in charge.
(a) 15 kVAr
3
-
-
... More
(b) 10 KVAr
3
-
-
... More
Supply and fix in repairs high quality digital flex board with LED light showing installation details with GI sheet frame of size 6'x4'fixed with iran angle complete mounted on PCC Pillars of installation entrance gate all as specified and directed
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%