Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date15 Oct 2024
Closing Date12 Nov 2024
Tender Amount₹ 3,920
Costs
EMD
₹ 78,400Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_679581_1Bid Award Id
ViewTender No
8170/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for all as specified and as directed
3.89
-
-
Demolition of cement concrete unreinforced in ground floors and pavings n.exc 15 cm thickness(below or above ground level) all as specified and as directed
9
-
-
Dismantling of single layer Mangalore pattern or similar tiles in roofing complete all as specified and as directed.
230
-
-
Dismantling of plain or corrugated steel sheeting, any gauge, thickness in roof coverings complete all as specified and as directed.
50
-
-
Dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed.
50
-
-
Dismantling timber scantlings 40 sqcm and over in section, in any position, framed work, complete all as specified and as directed.
0.4
-
-
Dismantling battens for tiles, shingles etc. of any size including tilting fillets spaced exc 15 cm complete all as specified and as directed.
230
-
-
Dismantling wrought or mild steel work of any description not otherwise provided for in any position complete all as specified and as directed.
13.48
-
-
Excavating in post holes (or similar holes) in hard/dense soil each not exc 0.5 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25 cm all as specified and as directed
18
-
-
S&F prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. Note: Colour and design of sheets shall be as approved by GE.
587
-
-
S&F prepainted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridges, hips, valley gutters, drip and straight flashings fixed with self tapping screws complete all as specified and as directed. Note: Colour and design of sheets shall be as approved by GE.
150
-
-
S&F 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc. fixed with L-type or J-type or cranked hook bolts complete all as specified and as directed.
600
-
-
S&F 6mm thick asbestos cement two piece serrated ridge for corrugated or semi corrugated sheets fixed with L-type or J-type or cranked hook bolts complete all as specified and as directed.
50
-
-
M&L in repairs, for water proofing treatment to RCC roof slab, including parapet, comprising with the following treatment/specifications from bottom to top:-
(i) Taking out old roof treatment and roughening the old concrete slab by picking, sweeping clean and washing down with water to remove dust etc and disposal of rubbish n exceeding 100 mtr distance from starting point.
(ii) Screed bed or bedding layer of 10 mm thick cement mortar 1:4 with mixing of WPC @ 3% by weight of cement or as per manufacturers instructions and surface finished even and smooth without using extra cement after applying a coat of cement slurry @ 3 kg/sqm for laying APP membrane. (iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.30 ltr /Sqm conforming to IS:3384-1986.
(iv) Providing APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) shall be applied over bituminous primer as specified above by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction.
(v) Applying two coat of aluminium paint over the APP modified membrane @ 0.11Kg/sqm. Note: Water proofing compound shall be measured & paid seperately.
350
-
-
Supply only water proofing compound, ISI marked
5.5
-
-
M&L for precast cement concrete interlocking tiles, (glossy finish/ rubber mat finish) of 80 mm thick, hydraulically pressed cemented tiles of grey colour with pigments,(glossy finish/ rubber mat finish) factory made, M-40 Grade conforming to IS-15658-2006, as in floor laid over & including 25 mm thick sand cusion and including filling of interstices with fine sand complete all as specified and as directed. Note : Size, shape & pattern of tiles shall be as approved by GE.
120
-
-
M&L for providing and laying at or near ground level factory made kerb stones of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specifed and as directed.
9
-
-
M&L for providing cement concrete 1:3:6, type C2 (using 40 mm graded stone aggregate) in foundations, mass concrete and filling complete all as specified and as directed .
3.89
-
-
S&F rolled mild steel sections as in main and cross beams, hip and jack rafters: purline where connected to common rafters and running rails fixed with angle cleats or other connecting plates of Fe 410-W (Gde-250) quality-A complete all as specified and as directed.
1000
-
-
M&L for perparation of new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
55
-
-
S&F galvanised corrugated mild steel sheeting, 0.63 mm thick, with two corrugations side lap, fixed with coach screws and washers, in roofs, wall etc. with grade of zinc coating 275, complete all as specified and as directed.
30
-
-
All as per serial item No. 24 here-in-before but except sheets
20
-
-
M&L for roof tiles, Mangalore pattern, interlocking at side joints laid dry complete all as specified and as directed .
200
-
-
All as per serial item No. 26 here-in-before but except tiles.
30
-
-
M&L for ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in cement mortar 1:6, complete all as specified and as directed.
30
-
-
All as per serial item No. 28 here-in-before but except ridge or hip tiles.
15
-
-
M&L for second class hard wood scantling, wrought, fixed in position complete all as specified and as directed.
0.4
-
-
M&L for second class hardwood, clean sawn, battens for tiles exc 5 Sqcm and not exc 15 Sqcm in section and fixed at 30 cm centres complete all as specified and as directed.
100
-
-
Fixing only second class hard wood battens for tiles of any section, fixed at 30 cm centres complete all as specified and as directed.
Note: Serviceable battens obtained from dismantling shall be reused.
130
-
-
M&L for preparation of new wood and old wood based surfaces, new of any description and girth not otherwise described and treated with two coats of creosote oil complete all as specified and as directed.
47
-
-
M&L for preparation of new wood and wood based surfaces of tiles battens any size and spacing, prepared and teated all over with creosote oil (measured overall on one side only, spaces not deducted) complete all as specified and directed.
100
-
-
M&L for elegant tiles made of perforated cement fiber composite, 595mm x 595mm / 295mm x 1195mm / 595mm x 1195, 5mm thick covered with absorptive microfiber coating on the front side and acoustics fiber on the back side, water resistance, fire resistant absorption coefficient upto 0.89 at 160 Hz tested as per ISO 354. The tiles are anti-sag with and including installation on T24 grid system of 0.6mm thick Main 'T' length minimum 3000mm, web minimum 35mm to be placed at 600mm center to center and secondary cross 'T' of length 600mm web minimum 35mm inter locked, wire support for main T to be taken at every 1200mm length wise and 600mm width wise, with a backing of 50mm 1000 GSM thick absorb wool tested as per fire retardant IS 15061-2002 for excellent results complete all as specified and as directed.
60
-
-
M&L for 4 mm thick non asbestos fibre cement building boards (decorative type) fixed or laid/ inserted to timber/Aluminium framework with screws complete all as specified and as directed.
1500
-
-
S & F anodised aluminium snap grid frame work of grid size 605mm x 605mm for false ceiling with 6mm dia GI hangers (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40mm x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long, complete all as specified and as directed.
1500
-
-
M&L for preparation of new surfaces of ceiling and applying two coats of distemper oil emulsion over a coat of chalk whiting complete all as specified and as directed.
1500
-
-
S&F mild steel work as in bands, straps, support for rain water pipes etc conforming to Fe 290 Gde-E-165 complete all as specified and as directed.
76
-
-
S&F in repair, 110mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints and fixed to walls all as specified and as directed.
42
-
-
S&F in repair 110 mm bore PVC (SWR) bends any radius complete as directed.
20
-
-
S&F in repair, 75mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints and fixed to walls all as specified and as directed.
17
-
-
S&F in repair, 75 mm bore (SWR) PVC bends any radius complete all as specified and as directed.
9
-
-
S&F mild steel work as in wind ties for roof including securing bolts complete including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
448
-
-
M&L for second class hard wood boarding planed one side with edges tongued and grooved or rebated, 15 mm thick as in eaves board/ barge board etc. complete all as specified and as directed.
30
-
-
M&L for preparation of new wood or wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
72
-
-
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fittings such as switches, bell push, holders, ceiling roses, pendants, regulators, sockets etc but excluding DBs, light fittings etc and making good disturbed surfaces of walls, floors etc. and matching with existing surface all as specified and as directed.
44
-
-
M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sqmm for phase and neutral, single core, multistranded copper conductor cable of 1100 Volts grade,conforming to IS-694 1990, PVC insulated and unsheathed , FRLS cable drawn through and including PVC casing and caping (ISI marked) and its accessories such as Tee, elbow, jointer, elbow corner etc. fixed on surface of walls, coloumns/ beams alongwith 1.5 Sqmm copper conductor cable (multistranded) PVC insulated and unsheathed FRLS cable as earth wire connected to common earth dolly at one end and metalic bodies of luminaire/ fan at other end including PVC boards for mounting switches, sockets, fan Regulators, accessories etc as specified and directed for one light point or one fan point controlled by one way switch . NOTES: (a). Proper colour coding shall be adopted for wiring (for phase-RED, YELLOW, BLUE for Earth-Green and Neutral-Black) (b) Wiring shall be done as per complaints received from user only on reqired basis it is not necessary to do whole wiring of any whole bldg.
(c). All points shall be earthed up to fixtures i.e holders, tube lights, all lights, ceiling lights, bulkhead lights, bldg security lights etc.
20
-
-
All as per serial item No. 48 here in before but for one 5 Amp 5 pin socket outlet point on same board with other switches including earth wire all as specified and as directed
6
-
-
All as per serial item No. 48 here in before but on independent board.
6
-
-
All as per serial item No. 48 here in before but for one bell/buzzer point controlled by one push button on the same board with other switches or independent all as specified and as directed.
6
-
-
All as per serial item No. 48 here in before but for one light point controlled by 2 way switches all as specified and as directed.
2
-
-
All as per serial item No. 48 herein before but with 2.5 Sqmm, PVC insulated and unsheathed copper multistranded cable FRLS type for phase,Neutral and earth for one 15 Amp, 6 pin socket on independent board all as specified and as directed.
4
-
-
S&F lamp holder, angle/ batten type, PVC/Polycarbonate with back plate, suitable for batten fittings all as specified & as directed.
5
-
-
S&F ceiling rose, surface PVC 50mm dia, 3 terminals including PVC mounting block white/ivory finish all as specified & as directed.
26
-
-
S&F bell, AC, 230 volts, single phase complete all as specified and as directed.
5
-
-
S&F modular switch one way, 6 Amp, one module, 230V all as specified and as directed.
32
-
-
S&F modular bell push, 6 Amp, one module, 230V all as specified and as directed.
6
-
-
S&F modular socket, 6A, 2/3 pin combined 2 module, 230V all as specified and directed.
14
-
-
S&F modular switch one way, 16 Amp, one module, 230V all as specified and as directed.
5
-
-
S&F modular socket, 6A/16A, 2/3 pin combined 2 module, 230V all as specified and directed.
5
-
-
S&F modular fan regulator, 120 watt, 2 module complete all as specifed and as directed.
2
-
-
S&F modular cover plate frame, 2 module complete all as specifed and as directed.
8
-
-
S&F modular cover plate frame, 3 module complete all as specifed and as directed.
8
-
-
S&F modular cover plate frame, 4 module complete all as specifed and as directed.
2
-
-
S&F modular cover plate frame, 6 module complete all as specifed and as directed.
4
-
-
S&F modular cover plate frame, 8 module complete all as specifed and as directed.
6
-
-
S&F square profile LED lighting fixture with extruded polycorbonate, environmental friendly, energy efficient ready to use pack LED Tube light fitting 20 Watt with LED light source 6500k with uniform light output, with all accessories including its connection with 3 core sheathed copper conductor cable of size 0.5 sqmm with complete all as specified and as directed. Make: HAVELLS COMPY VIZON Cat No LHEXARP7SN1W020 or equivalent makes CG/Philips/wipro/Jaguar.
5
-
-
S&F in replacement LED tube rod of capacity 20 watt LED light source 6500K with uniform light output complete with all accessories . Make - Havells Cat Part No MAXOLED (TUBE) LHLDDCXCML8Q020 or equivalent in Philips/ CG/ Wipro/Jaguar .
4
-
-
S&F square profile LED lighting fixture with extruded polycorbonate, environmental friendly, energy efficient ready to use pack LED tube light fitting 10 Watt with LED light source 6500k with uniform light output,with all accessories including its connection with 3 core sheathed copper conductor cable of size 0.5 sqmm with complete with all as specified and as directed.Make : HAVELLS E-LITE LED PRIDE PLUS NEO Cat No LHEXACP5IN1W010 or equivalent in make CG/Philips/wipro/Jaguar.
4
-
-
M&L for sub main wiring with 2 runs of 10 sqmm, single core, PVC insulated & unsheathed FRLS cable conforming to IS-694, 1100 volts with copper conductor, multi stranded drawn in and including suitable size heavy grade casing caping (ISI marked) with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 10 sqmm single core PVC insulated & unsheathed FRLS copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduit complete all as specified and as directed. NOTES: (a) Proper colour coding shall adopted for wiring (for Phase- RED, YELLOW, BLUE for Earth -Green and Neutral-Black)
(b) Three runs of 10 sq.mm cable and one run of PVC casing & caping shall be measured as one unit.
25
-
-
M&L for sub main wiring with 2 runs of 6 sqmm, single core, PVC insulated & unsheathed FRLS cable conforming to IS-694, 1100 volts with copper conductor, multi stranded drawn in and including suitable size heavy grade casing caping (ISI marked) with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6 sqmm single core PVC insulated & unsheathed FRLS copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduit complete all as specified and as directed. NOTES: 1.Proper colour coding shall adopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black)
2. Three runs of 6 sq.mm cable and one run of PVC casing & caping shall be measured as one unit.
30
-
-
M&L for sub main wiring with 2 runs of 4 sqmm, single core, PVC insulated & unsheathed FRLS cable conforming to IS-694, 1100 volts with copper conductor, multi stranded drawn in and including suitable size heavy grade casing caping (ISI marked) with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4 sqmm single core PVC insulated & unsheathed FRLS copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduit complete all as specified and as directed. NOTES: (a) Proper colour coding shall adopted for wiring (for phase-RED,YELLOW, BLUE for Earth-Green and Neutral-Black)
(b) Three runs of 4 sq.mm cable and one run of PVC casing & caping shall be measured as one unit.
60
-
-
S&F in repairs, MCB SP, AC 240 V, 6 to 32 Amps, 10 KA capacity ,'C' series, making connection with suitable size of copper lugs etc complete all as specified and as directed.
4
-
-
S&F in repairs, MCB SPN, AC 240 V, 6 to 32 Amps, 10 KA capacity ,'C' series, making connection with suitable size of copper lugs etc complete all as specified and as directed.
2
-
-