Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date21 Nov 2024
Closing Date11 Dec 2024
Tender Amount₹ 50,00,000
Costs
EMD
₹ 1,00,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_685014_1Tender No
8189/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
All as per serial item No 02 but for one 3/5 pin 6 Amp Socket outlet point on same board with other switches including earth wire as per description given above and connected to common earth and earth terminals.
150
-
-
All as per serial item No 02 but for one 5 pin 6 Amp Socket outlet point on independent board including earth wire as per description given above and connected to common earth and earth terminals
150
-
-
All as per serial item No 02 but for one light point controlled by two way switches
6
-
-
All as per serial item No 02 but with 2.5 Sqmm cables for one 16A, 6-Pin ( mulipurpose) socket outlet point on independent board with & including 2.5 Sqmm FRLS (H) cable as earth wire complete all as specified and as directed.
80
-
-
All as per serial item No 02 but with 4.0 Sqmm cables for one 16A, 6-Pin socket outlet point on independent board with & including 4.0 Sqmm FRLS (H) cable as earth wire complete all as specified and as directed.
30
-
-
M & L point wiring complete with and including single core PVC insulated unsheathed flexible bright annealed multi stranded copper conductor FRLS (H) cables 1.5 Sqmm (22/0.30 mm) 1100 volts grade drawn through and including heavy grade PVC rigid conduits 20 mm or higher dia as reqd at site, totally concealed in walls/floors/ceiling including all conduit accessories/ fittings/ junction boxes/ inspection covers etc; of heavy grade, ISI marked and sunken terminal boxes of factory made 16 SWG pressed steel housing, totally concealed in walls with 3 mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk/cup washers, for mounting of switches, sockets fan regulates etc; including 1.5 Sqmm (22/0.30 mm) 1100 V grade PVC insulated, unsheathed flexible multi stranded copper conductor FRLS (H) cable as continuous earth wire connected to metallic bodies of luminaries/fans etc; at one end and to common earth dolly at other end, all as specified & directed for light point or one fan point controlled by one, one way switch (Note: The unit rate quoted shall deeemed to be included cutting chases in walls for concealed wiring & making good disturbed surfaces .
50
-
-
All as per serial item No 09 but for one light point controlled by two way switches
2
-
-
All as per serial item No 09 but for one bell / buzzer point controlled by one push button on the same board with othter or independent
2
-
-
All as per serial item No 09 but for one 3 pin 6 Amp Socket outlet point on same board with other switches including earth wire as per description given above and connected to common earth and earth terminals.
10
-
-
All as per serial item No 09 but for one 3 pin 6 Amp Socket outlet point on independent board including earth wire as per description given above and connected to common earth and earth terminals.
15
-
-
All as per serial item No 09 but with 2.5 Sqmm cables for one 16A, 6-Pin socket outlet point on independent board with & including 2.5 Sqmm FRLS (H) cable as earth wire complete.
10
-
-
S&F modular switch single pole one way 10 Amps 1 module complete all as specified and as directed.
1095
-
-
S&F modular switch single pole one way 20 Amps 1 module complete all as specified and as directed.
120
-
-
M&L of modular Bell Switch 10 Amp 1 Module complete all as specified and as directed.
17
-
-
S&F modular Switch 2 way 1 module complete all as specified and as directed.
8
-
-
S&F modular socket 10 Amp-2/3 pin combined 2 module complete all as specified and as directed.
325
-
-
S&F modular socket 20 Amp -2/3 pin combined 2 module complete all as specified and as directed
120
-
-
S&F modular fan regulator Step Type, 120W-2 Module Complete all as Specified and as directed.
100
-
-
S&F ceiling rose surface bakelite three terminal type complete all as specified and as directed.
589
-
-
S&F in replacement decorative ultra slim square profile LED lighting fixture with extruded polycarbonate,environmental friendly, energy efficient of capacity 20 Watt , 6500 K with inbuilt driver complete fitting and all other accessories fitting arrangements including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Make : Cat No. LHEXACP7IN1W020 of Havells or equivalent of makes specified in PS
400
-
-
S&F in replacement decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient of capacity 10 Watt , 3000 K with inbuilt driver complete fitting and all other accessories fitting arrangements including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Make : Cat No. LHEXACP5IN1W010 of Havells or equivalent of makes specified in PS
50
-
-
S&F in replecement LED light fitting 1x 9W / 1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
30
-
-
S&F in replecement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
35
-
-
S&F in replecement unique slimlest recess cum surface LED panel ED luminaire 300 mm x 300 mm, 24 watt, 6500K, 220 V AC with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
20
-
-
S&F in replacement round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with flexible copper conductor cable of suitable size complete all as specified and directed.
20
-
-
S&F in replecement lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
200
-
-
S&F in replecement lamp 3 Star LED 9 Watt, 230 volts 50 Hz AC complete all as specified and as directed.
50
-
-
S&F in replacement MCB DB double door 4 way TPN with suitable rated busbar 240 V complete all as specified and as directed.
6
-
-
S&F in replacement MCB DB double door 16 way SPN with suitable rated busbar 240 V complete all as specified and as directed.
6
-
-
S&F in replacement MCB DB double door 12 way SPN with suitable rated busbar 240 V complete all as specified and as directed.
8
-
-
S&F in replacement MCB DB double door 8 way SPN with suitable rated busbar 240 V complete all as specified and as directed.
12
-
-
S&F in replacement MCB DB double door 4 way SPN with suitable rated busbar 240 V complete all as specified and as directed.
6
-
-
S&F in replacement MCB DB single door 2 way SPN with suitable rated busbar 240 V complete all as specified and as directed.
10
-
-
S&F in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amp 240 Volts complete all as specified and as directed.
10
-
-
S&F in replacement of MCB SP, C Curve, 6 to 32 Amps 10 KA single pole AC 230 volts complete all as specified and as directed.
180
-
-
S&F in replacement of MCB SPN, C Curve, 40-63 Amps 10 KA single pole AC 230 volts complete all as specified and as directed.
32
-
-
S&F in replacement of MCB C Curve TPN 40-100 Amps, 415 V complete all as specified and as directed.
10
-
-
S&F in replacement of MCB C Curve TPN 16-32 Amps, 415 V complete all as specified and as directed.
4
-
-
S&F in replacement of bell multi music type, AC, 230 volts, single phase complete all as specified and as directed.
50
-
-
M&L for sub main wiring with 2 runs of 6.0 sqmm, single core, PVC insulated & unsheathed FRLS cable, conforming to IS-694, 1100 volts with copper conductor, multi stranded, drawn in and including suitable size PVC Casing Capping (ISI marked) with all accessories such as Tees, Elbows, junction box etc as requied alongwith one run of 6.0 sqmm single core PVC insulated & unsheathed FRLS copper conductor cable as continuous earth wire dolly and connecting to existing main switch board / distribution board of each building as ordered and testing on completion including taking down old submain wiring and any type of casing/caping/Conduit complete all as specified and as directed. Note : Three runs of 6.0 Sqmm cable and one run of PVC casing/caping will be measured as one unit.
150
-
-
M&L for sub main wiring with 2 runs of 4.0 sqmm, single core, PVC insulated & unsheathed FRLS cable, conforming to IS-694, 1100 volts with copper conductor, multi stranded, drawn in and including suitable size PVC Casing Capping (ISI marked) with all accessories such as Tees, Elbows, junction box etc as requied alongwith one run of 4.0 sqmm single core PVC insulated & unsheathed FRLS copper conductor cable as continuous earth wire dolly and connecting to existing main switch board / distribution board of each building as ordered and testing on completion including taking down old submain wiring and any type of casing/caping/Conduit, complete all as specified and as directed. Note : Three runs of 4.0 Sqmm cable and one run of PVC casing/caping will be measured as one Rm unit.
150
-
-
M&L for sub main wiring with 2 runs of 2.5 sqmm, single core, PVC insulated & unsheathed FRLS cable, conforming to IS-694, 1100 volts with copper conductor, multi stranded, drawn in and including suitable size PVC Casing Capping (ISI marked) with all accessories such as Tees, Elbows, junction box etc as requied alongwith one run of 2.5 sqmm single core PVC insulated & unsheathed FRLS copper conductor cable as continuous earth wire dolly and connecting to existing main switch board / distribution board of each building as ordered and testing on completion including taking down old submain wiring and any type of casing/caping/Conduit, complete all as specified and as directed. Note : Three runs of 2.5 Sqmm cable and one run of PVC casing/caping will be measured as one unit.
150
-
-
M &L for sub main wiring with 2 single core FRLS PVC insulated unsheathed, multi stranded flexible copper conductor 1100 volts grade cables 4.0 Sqmm drawn through concealed conduit and including PVC conduit heavy grade with and including 1 single core 4.0 Sqmm 1100 V grade FRLS PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals including taking down old sub main wiring complete all as specified and as directed. Note: Two runs of 4.0 Sqmm cable, one run of 4.0 Sqmm cable and one run of PVC Conduit will be measured as one unit.
50
-
-
M &L for sub main wiring with 2 single core FRLS PVC insulated unsheathed, multi stranded flexible copper conductor 1100 volts grade cables 6.0 Sqmm drawn through concealed conduit and including PVC conduit heavy grade with and including 1 single core 6.0 Sqmm 1100 V grade FRLS PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals including taking down old sub main wiring complete all as specified and as directed. Note: Three runs of 6.0 Sqmm cable and one run of PVC Conduit will be measured as one Rm unit.
50
-
-
M &L for sub main wiring with 2 single core FRLS PVC insulated unsheathed, multi stranded flexible copper conductor 1100 volts grade cables 2.5 Sqmm drawn through concealed conduit and including PVC conduit heavy grade with and including 1 single core 2.5 Sqmm 1100 V grade FRLS PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals including taking down old sub main wiring complete all as specified & directed. Note: Three runs of 2.5 Sqmm cable and one run of PVC Conduit will be measured as one unit.
30
-
-
S&F in replacement 1100 Volt grade, heavy duty cable PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire one twin core cable flat of stranded multistranded conductor of size 4.0 Sqmm complete all as specified and as directed.
270
-
-
S&F in replecement 1100 Volt grade, heavy duty cable PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape and over all pvc sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire one twin core cable flat of stranded multistranded conductor of size 6.0 sqmm complete all as specified and as directed.
180
-
-
S&F in replacement 1100 Volt grade heavy duty cable PVC insulated aluminium Stranded conductor served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire one twin core cable flat of stranded multistranded conductor size 10.0 sqmm complete all as specified and as directed.
90
-
-
S&F in replacement 35/40 Watt building mounted LED security light fitting complete made up of pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 & 10KV external SPD, including GI bracket made out of GI pipe 40/50 mm bore, medium grade pipe 1.2m long bend to shape required fixed to pole / wall with 02 Nos MS clamps made out of flat iron 40x5 mm including nuts, bolts and washer, painting with two coats aluminium paint over a coat of primer, suitable for LED fitting complete all as specified and as directed.
50
-
-
S&F in replacement garden light of Bamboo type-IP 65 of capacity 9/8 watt, 5000K new generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape luminaire for diffused lighting with high power LED as light source with PCC Base for fixing of lights with proper nut & bolts including electrical connection wire complete all as specified and as directed. Make- Cat part No
BAMBOOBLBWLED857SSYMTOPC of Havells or equivalent of makes specified in PS
23
-
-
Supply, laying, testing and commissioning of UG LT cables, 35 Sqmm x 3.5 core, 1100 volts grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip or wire armoured with multi stranded aluminium conductor, ISI marked, heavy duty including cable glands, cable lugs in LT panel/MDB in building etc to suit the cable including material and labour for all jointing/connecting material as required size, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall including taking out old cable and cable covers complete all as specified and directed.
120
-
-
All as per serial item No 54 but for cable 25 Sqmm x 3.5 core
100
-
-
All as per serial item No 54 but for cable 16 Sqmm x 4.0 core
80
-
-
All as per serial item No 54 but for cable 10 Sqmm X 2.0 Core
400
-
-
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for shafts, wells, manholes, pier holes, laying of cable & pipes etc not exceeding 10 sq m on plan not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
162
-
-
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick as in soil complete all as specified and as directed.
139
-
-
Removing excavated surplus soil to a distance n.exc. 50 m and depositing where directed at a level not exceeding 1.5 m from the starting point complete all as specified and as directed.
23
-
-
M&L in replacement for GI tubing 40 mm bore light grade for protection of cable with all necessary fittings accessories such as MS 40x3mm clamps of suitable length, nuts, bolts and washers and fixed complete to wall/ceiling or laid under floors complete all as specified and as directed.
40
-
-
M&L for Double Walled Corrugted (DWC) HDPE pipe of outer dia 50 mm and Internal dia 38 mm including 90 degree bends with coupler and rubber ring laid in trenches suitable for cable protection complete all as specified and as directed.
400
-
-
S&F in replacement of LED driver unit ISI marked suitable for recessed mounting fitting of 15/18 Watts complete all as specified and as directed.
Make :- Cat No. LSSLNW0170 of Havells or equivalent of makes specified in PS
10
-
-
S&F in replacement of LED driver unit ISI marked suitable for recessed mounting fitting of 24 Watts complete all as specified and as directed.
Make :- Cat No. LSSLNW0171 of Havells or equivalent of makes specified in PS
15
-
-
Taking down electric water heater (geyser) of any type/capactiy for repairs, dismantling the accessories carefully after disconnecting the water/electric connection and transporting to workshop (if required) for repairs and refixing the same in original position after repairs and connecting up the water/electric connections including testing complete all as specified and as directed. Note : Replacement of unserviceable parts shall be measured and paid seperately.
120
-
-
S&F in replacement heating element, triangular or square type, 1500watts, 230 volts, suitable for geyser and as per approved sample all as specified and as directed.
60
-
-
S&F in replacement heating element, triangular or square type, 2000watts, 230 volts, suitable for geyser and as per approved sample all as specified and as directed.
50
-
-
S&F in replacement thermostat, auto cut with thermal setting upto 80 degree centigrade, 230 Volts, suitable for existing geysor(25/35/50 lit) of various capacities all as specified and as directed.
80
-
-
S&F in replacement inner copper water storage tank of 25 ltr capacity geyser existing at site all as specified and as directed.
10
-
-
S&F in replacement psyphon assembly suitable for 25 ltr capacity geyser as per existing at site all as specified and as directed.
30
-
-
S&F in replacement indicator, lamp red/green for geyser all as specified and as directed.
60
-
-
S&F in replacement, aperture plate assembly complete suitable for 25 Ltrs capacity geyers existing at site all as specified and as directed.
15
-
-
S&F in replacement, 15mm bore dia, non return valve, cast copper alloy suitable for geyser all as specified and as directed.
15
-
-
S&F in replacement, 15mm bore dia, pressure release valve, cast copper alloy suitable for geyser all as specified and as directed.
15
-
-
S&F in replacement glass wool in geyser of 25/50 litre capacity all as specified and as directed.
10
-
-
S&F in replacement, drain plug for 25/50 litre capacity geyser all as specified and as directed.
30
-
-
S&F in replacement, 15mm bore dia, stop valve, fancy type, cast copper alloy, chromium plated, screwed for iron pipe and fixed all as specified and as directed.
10
-
-
S&F in replacement for mild steel hold fast/fasteners fixing to wall, suitable for hanging of geyser of any capacity including making good surface with cement mortar 1:4 and surface finished as per existing surfaces including taking down old existing hold fasts/brackets complete all as specified and as directed.
20
-
-
S&F in replacement, heat resistant, PVC, flexible connection pipe, 450 mm long, suitable for 15 mm dia pipe with brass creamed nipple and nuts, heavy duty pressure grade 6 Kg/cm2 all as specified and as directed.
120
-
-
S&F in replacement 15mm bore GI pipe, medium grade with all fitting and fixed complete to walls and ceilings or laid in floor complete including taking up or down old pipe all as specified and as directed.
50
-
-
S&F in replacement 16mm dia 3-layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings (Including all type of fittings like bends, sockets,Tees, etc) of fixed complete to walls, ceilings or in floors etc. complete all as specified and as directed.
50
-
-
Taking out the old thermostat/heating element and refixing the same after descaling/ cleaning and making electrical connection and calibrating/adjusting to a temperature rating as per manufacturer recommendations all as specified and as directed.
30
-
-
S&F in replacement of plug top 3 pin of capacity 15/16 Amp complete all as specified and directed by Engr in Charge.
20
-
-
Taking down from site or collecting from E/M yard, unserviceable (burnt) ceiling fan, 1200 mm sweep, any make, with blades, transporting to local workshop, opening, cutting and taking out complete copper winding, cleaning with Kerosene oil /Diesel/ Terpentine oil and dried out, rewinding with new super enamelled copper wire of suitable size and gauge and number of turns as recommended by the respective manufactures, varnishing and heating the winding including providing paper insulation (cuff/strip type) replacing unserviceable providing paper insulation (cuff / strip type) replacing unserviceable / missing spare (bush, bearing, capacity shackle insulator, canopy, nuts, bolts, earthing, screw, upper, socket, CI block , quarter /split pin (top & bottom) , lock nut etc) fixing the stator in rotor properly aligned and reassembling ensuring right DOR, speedy and noiseless running and depositing in E/M yard and hanging at site in position complete all as specified and as directed.
Note : Bush, bearing, capacitor and canopy, shackle insulator with nuts, bolts and sockets shall be measured and paid separately as supply only but fixing in repairs/replacement shall deemed to be included in the unit rate quoted against the item.
650
-
-
All as per serial item No 84, but ceiling fan 1400 mm sweep.
120
-
-
All as per serial item No 84, but exhaust fan 300 mm sweep.
50
-
-
All as per serial item No 84, but exhaust fan 380/ 450 mm sweep.
20
-
-
All as per serial Item No 84, but wall mounted fan/table fan/cabin fan /Padestal fan of any sweep.
5
-
-
all as per serial item No 84, but Air circulating wall mounted fan above 450 mm, upto 600 mm sweep
2
-
-
Taking down from site or collecting unserviceable ceiling fan of any sweep and make from E/M yard, transporting to local workshop, cleaning external portion with washing soda for removing oily stain, opening and cleaning internal portion with Kerosene oil, drying it out, oiling / greasing properly, replacing unserviceable bearing / bush / rubber bush for arm with nuts & clamp / flexible wire and reassembling ensuring speedy and noiseless run and hanging the same at site complete all as specified and as directed.
Note :- (i) Spares if required shall be measured and paid separately under respective items as supply only, however cost for fixing in repairs/replacement shall deemed to be included in the unit rate quoted. (ii) Repairs to winding is not included in this item.
400
-
-
Taking down from site or collecting unserviceable exhaust fan of any sweep and make from E/M yard, transporting to local wksp, cleaning external portion with washing soda for removing oily stain, opening and cleaning internal portion with kerosene oil, drying it out, oiling / greasing properly, replacing unserviceable bearing / bush / rubber bush for arm with nuts & clamp / flexible wire and reassembling ensuring speedy and noiseless run and hanging the same at site complete all as specified and as directed.
Note :- (i) Bush, bearing, capacitor and canopy, shackle insulator with nuts, bolts and sockets shall be measured and paid separately as supply only but fixing in repairs/replacement shall deemed to be included in the unit rate quoted against the item.
(ii) Repairs to winding is not included in this item.
50
-
-
Supply only bush, suitable for ceiling fan /exhaust fan/Table fan of any sweep complete all as specified and as directed.
800
-
-
Supply only ball bearing (No 6201,6202,6203 or 6204) suitable for 1200 / 1400 mm sweep ceiling fan complete all as specified and as directed.
1300
-
-
Supply only capacitor 2.50 mfd to 3.15 mfd complete all as specified and as directed.
770
-
-
Supply only capacitor 4 mfd, for exhaust fan/wall mounted fans etc of 300mm / 450mm / 600 mm sweep complete all as specified and as directed.
75
-
-
Supply only canopy for ceiling fan (top and bottom), any size & make complete all as specified and as directed.
30
-
-
Supply only MS fan rod and clamps with rubber seal including nuts and bolts, split pin, suitable for ceiling fan 1200 / 1400 mm sweep complete all as specified and as directed.
30
-
-
Supply only ceiling fan blade set of 3 piece of aluminium sheet suitable for 1200 mm sweep, matching with the existing colour brown / white etc. complete all as specified and as directed.
10
-
-
Supply only ceiling fan blade set of 3 piece mild steel sheet, suitable for 1400 mm sweep matching with the existing colour brown / white etc. complete all as specified and as directed.
4
-
-
M&L for preparation of surfaces and spray painting to ceiling fans (in situ) of any type, size and make, with super enamelled heat resistant synthetic white paint duly filling the cavities with filler and rewriting the MES number in black paint in appropriate size and shape all as specified and as directed.
610
-
-
M&L for preparation of surfaces and spray painting to exhaust fans (in situ) of any type , size and make, with super enamelled heat resistant synthetic white paint duly filling the cavities with filler and re-writing the MES number in black paint in appropriate size and shape all as specified and as directed.
50
-
-
M&L for preparation of surfaces and spray painting to wall mounted fans/air circulating fans, pedestal fans etc (in situ) of any type , size and make of with super enamelled heat resistant synthetic white paint duly filling the cavities with filler and re-writing the MES number in black paint in appropriate size and shape all as specified and as directed.
2
-
-
Supply & fix Emergency/Inverter lamp in replacement of old Bulb any type with Emergency Back up up to 3-4 Hrs High grade thermal plastic housing with Al Heat sink for better thermal management , 100 lumen/watt PF0.90 operating voltage 100 to 300 V Eco friendly (No Mercery ) CCT 6500 of capacity 12 watt complete all as specified and directed by Engr in Charge.
400
-
-
S&F in replacement Emergency/Inverter tube light decorative ultra slim/ square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient of capacity 20 Watt , 6500 K with inbuilt driver, luminous efficiency 90 LM/watt, complete fitting and all other accessories fitting arrangements including connecting up with suitable flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
408
-
-
M&L in repairs/replacement earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground( earth pit not less than 2.25 mtrs deep below normal ground level) with the top edges of plate not less than 1.5 mtrs below normal ground level connected to GI wire 4mm by means of GI nuts, bolts check nuts and washers earth lead protected by 15mm dia GI pipe light grade and connected to main distribution board/earthing test point all as shown in electrical plate No 5 of SSR part 1 and all as specified including testing on completion. Notes:-The unit rate also including for excavation, earth work in any type of strata, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix, type B1 cover reinforced with 8mm dia TMT bars @150mm C/C both ways ,GI funnel with watering pipe, wire mesh, protection pipe for earth lead upto 7.50m long complete in addition to item No. 1(a) to (e) preamble (notes) under sub heading earthing, specified in SSR Part ll. Earth strip beyond 7.5m shall be measured and paid separately.
5
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%