Military Engineer Services Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date27 Jan 2025
Closing Soon15 Feb 2025
Tender Amount₹ 24,70,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M & L for point wiring with FRLS insulated 1100 Volts grade single core multistranded Copper conductor cable 1.5 Sqmm drawn and including PVC casing capping and accessories, fixed on wall/ ceiling etc with necessary fixing accessories and earth continuity conductor cable of size 1.5 Sqmm green colour Connected to common earth dolly including pressed steel terminal boxes concealed in wall Covered with laminated sheet top cover of required thickness for mounting switches/ sockets/ fan regulators / bell push buttons etc fixed with cadmium plated machine screws and washers all as specified for the following :-

-

-

-

... More
(i) One light / fan/bell point controlled by one way switch

250

-

-

... More
(ii) One socket outlet 5 Amps on independent board

75

-

-

... More
(iii) One socket outlet 5 Amps on the same board

25

-

-

... More
All as per above herein before but with 2.5 Sqmm for phase & neutral and 2.5 sqmm for earth wire for socket out let 15 Amps complete all as specified and directed

75

-

-

... More
All as per above herein before but with 4 Sqmm for phase & neutral and 4 sqmm for earth wire for AC point independent 15 AMP complete all as specified and directed

20

-

-

... More
M & L for point wiring with FRLSinsulated 1100 Volts grade single core multistranded Copper conductor cable 1.5 Sqmm drawn and including PVC conduit and accessories, concealed in wall conduit on ceiling (for fan/down lighter only) etc with necessary fixing accessories and earth continuity conductor cable of size 1.5 Sqmm green colour Connected to common earth and earth dolly including pressed steel terminal boxes concealed in wall Covered with laminated sheet top cover of required thickness for mounting switches/ sockets/ fan regulators / bell push buttons etc fixed with cadmium plated machine screws and washers including making good the disturbed surface and painting the surface with colour matching to the wall colour all as specified for the following :-

-

-

-

... More
(i) One light / fan/bell point controlled by one way switch

120

-

-

... More
(ii) One socket outlet 5 Amps on independent board

65

-

-

... More
(iii) One socket outlet 5 Amps on the same board

25

-

-

... More
All as per Srl Item No 10.00 above herein before but with 2.5 Sqmm for phase & neutral and 2.5 sqmm for earth wire for socket out let 15 Amps complete all as specified and directed

35

-

-

... More
All as per Srl Item No 10.00 above herein before but with 4 Sqmm for phase & neutral and 4 sqmm for earth wire for socket out let 15 Amps complete all as specified and directed

10

-

-

... More
Supply and Fix in repairs of Switch piano flush type single pole one way 5 Amp complete all as specified and directed .

230

-

-

... More
Supply and Fix in repairs of Ceiling rose surface bakelite two to three terminal complete all as specified and directed .

220

-

-

... More
Supply and Fix in repairs of Fan regulator electronic step type 240 V complete all as specified and directed .

50

-

-

... More
Supply and Fix in repairs of Bell push flush type 5 Amps complete all as specified and directed .

20

-

-

... More
Supply and Fix in repairs of Electronic Call Bell 230 volts single pole AC complete all as specified and directed .

20

-

-

... More
Supply and Fix in repairs of Switch socket combined two in one 06 pin 5/15 Amps flush type universal complete all as specified and directed .

110

-

-

... More
Supply and Fix in repairs of Switch Socket multipurpose 5 pin 5 Amps 240 V flush type complete all as specified and directed .

140

-

-

... More
Supply and Fix in repairs of Lamp holder,insulated body with back plate complete all as specified and directed

30

-

-

... More
M&L MCCB DB vertical type made of sheet steel , powder painted with neutral bus bar 200 A, neutral link, IP-30-IK08 protection grade , 415Volts TPN with 8 way Double door complete all as specified and directed,

2

-

-

... More
M&L MCCB DB vertical type made of sheet steel , powder painted with neutral bus bar 200 A, neutral link, IP-30-IK08 protection grade , 415Volts TPN with 4 way Double door complete all as specified and directed

4

-

-

... More
M&L MCCB TPN 100 Amps , 415Volts, 25KA ,3 Pole complete all as specified and directed

4

-

-

... More
M&L MCCB TPN 160 Amps , 415Volts, 25KA ,3 pole complete all as specified and directed

2

-

-

... More
Supply and Fix in repairs of MCB DB SPN 8 Way Double door type 240 Volts complete all as specified and directed .

10

-

-

... More
Supply and Fix in repairs of MCB DB TPN 4 Way double door type 415 V with bus bar complete all as specified and directed

3

-

-

... More
Supply and Fix in repairs single pole and neutral enclosure with a two pin and earth and metal clad plug socket complete with one single pole MCB 25 Amp 240 Volts complete all as specified and directed.

30

-

-

... More
Supply and Fix in repairs of MCB TPN 63 Amps 415 Volts complete all as specified and directed .

3

-

-

... More
Supply and Fix in repairs of MCB SP 06 to 32 Amps 240 Volts complete all as specified and directed .

120

-

-

... More
Supply and Fix in repairs of SPN 6- 32 Amps 240 Volts complete all as specified and directed .

30

-

-

... More
Supply and Fix in repairs of MCB SPN 40 Amps 240 Volts complete all as specified and directed

20

-

-

... More
Supply and Fix in repairs of MCB SPN 63 Amps 240 Volts complete all as specified and directed .

8

-

-

... More
NOTE FOR ITEM NO 24 to 35 -(1).The unit rate includes for cutting the brick walls to accommodate DB to make flush to wall./ DB to be fixed on wall including frame made out of MS flat 40x5mm(2).The unit rate includes for making good the disturbed surfaces including finishes to match with the adjoining surface

-

-

-

... More
M&L for Sub Main wiring with two single core 2.5 Sqmm FRLS insulated multistranded flexible copper conductor cable 660/1100 volts grade drawn in through rigid flexible PVC casing -n- capping/PVC conduit with and including PVC insulated 2.5 Sqmm single core multi strand copper conductor as continuous earth wire in green colour connected to common earth dolly all as specified and as directed. Note:- 1. Two runs of cable and one run of earth wire inch PVC conduit will be measured and paid one unit. 2. Separate sub main wiring will be run for each acne

120

-

-

... More
M&L for Sub Main wiring complete with 4.0 Sqmm FRLS insulated 1100 Volt grade with multistranded copper conductor cable with and including drawn through PVC casing -n- capping/PVC conduit with all accessories fixed on Walls/floors/roofs with and including pressed steel terminal sunken boxes fixed on the existing sunken portion (Where the old boxes are removed under respective item) with 3 mm laminated bakelite sheet top cover fixed with cadmium plated screws, cup washer for housing metal clad plug socket for AC Point including provision of 4 sqmm PVC insulated copper wire as earth continuity conductor and connecting to common earth dolly all as specified.

210

-

-

... More
All as per Srl Item No 38.00 above herein before but with 6 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable drawn in through PVC casing -n- capping/PVC conduit complete with all accessories including provision of 6.0 sq. mm FRLS insulated copper wire as earth continuity conductor all as specified and as directed.

350

-

-

... More
S & F LED retrofit lamp B-22 holder based with polycarbonate body and aluminium heat sink with warm white, 7W LED Lamp, all as specified and as directed by Engr-in-Charge.

99

-

-

... More
S & F LED retrofit lamp B-22 holder based with polycarbonate body and aluminium heat sink with warm white, 9W LED Lamp, all as specified and as directed by Engr-in-Charge at site

99

-

-

... More
S&F energy efficient light emitting LED light fitting 1x 18/20 watt, four feet , white fittings with LED rod complete with all accessories & Provn of three core cable of copper conductor of size 0.75 sqmm, making necessary electric connection from ceiling rose to fitting terminal , fixing the fitting on wall including all necessary fixing accessories complete all as directed

310

-

-

... More
S&F for energy efficient light emitting LED light fitting 1x10 watt Two feet LED tube light with LED rod complete with all accessories & Provn of three core cable of copper conductor of size 0.75 sqmm, making necessary electric connection from ceiling rose to fitting terminal , fixing the fitting on wall including all necessary fixing accessories complete all as directed .

25

-

-

... More
S&F in Repairs LED Light luminaries Square type 36W suitable suitable for Modular/pop/Gypsum ceiling with starter, connector block, etc,complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible conductor of copper with PVC square blocks of size 600mmX600mm for fixing the fitting complete all as specified and directed.

30

-

-

... More
Material and labour Modular white cover plate with frame of following types complete all as specified and directed. Of the following:-

-

-

-

... More
(a) White cover plate with frame, 1 module

20

-

-

... More
(b) White cover plate with frame 2 module

20

-

-

... More
(c) White cover plate with frame 4 module

25

-

-

... More
(d) White cover plate with frame 6 module

25

-

-

... More
(e) White cover plate with frame 8 module

32

-

-

... More
Material and labour Modular switch 1 way 6A, 1 module complete all as specified and directed

32

-

-

... More
Material and labour Modular Bell push, flush type, 5 amp complete all as specified and directed

24

-

-

... More
Material and labour Fan step regulator, 120W - 2 module complete all as specified and directed

25

-

-

... More
Material and labour Modular metal box flush type 1 /2/3 module complete all as specified and directed

25

-

-

... More
Material and labour Modular metal box flush type 4 module complete all as specified and directed

25

-

-

... More
Material and labour Modular metal box flush type 6 module complete all as specified and directed

32

-

-

... More
Material and labour Modular Switch socket outlet multipurpose 3 pin, 15 amp and one pin, 5 amp controlled by one switch 16 Amps complete all as specified and directed

50

-

-

... More
Draining out the old slugs oil from the DG set and replace with new oil as recommended by Mfg. NOTE : Draining out of Oil shall be done twice in year each time refiling/Top up will be measured & paid separately.

100

-

-

... More
Disconnecting old unserviceable battery 12 Volts DC upto 180 AH from Engine & transporting to work shop for refilling electrolyte, distilled water, checking of sp gravity complete & initial charging of the battery for 48 hours min, transporting back to site , reconnecting up complete all as directed by EIC at site

2

-

-

... More
M&L for in Replacement of timer assembly with four pole selector switch complete including alteration of existing wiring for power pass in existing panel for DG SET 15 KVA to 160 KVA all as directed. Make : L&T or equivalent.

1

-

-

... More
Servicing of AMF Panel suitable for DG Set DG Set15 KVA to 160 KVA including cleaning properly with blower, checking of control wiring , replacement of burnt out / damaged wiring connections, calibration of control relay, replacement of control fuses / MCBs all as directed by Engineer in Charge. NOTE :- Spare parts shall be measured and paid separately in respective item of this schedule if required.

2

-

-

... More
M&L for in replacement LED type Indicator

3

-

-

... More
M&L for in replacement Control relay 9/11 pin 12 /24 volt DC Make : AMRON or equivalent.

2

-

-

... More
M&L for in replacement Digital ammeter with built in selector switch Make : NIPPON / CONZERVE

1

-

-

... More
M&L for in replacement Micro processor unit for automatic and manual function as specified Make : Kirloskar or equivalent.

2

-

-

... More
M&L for in replacement Contactor Type ML-4. Make:- L&T or equivalent.

2

-

-

... More
M&L for in replacement Contactor Type ML-2. Make:- L&T or equivalent.

2

-

-

... More
M&L for in replacement CT of ratio upto 150 / 5 10 VA burden Make:- AE/NIPPON

1

-

-

... More
M&L for in replacement Fault Indicator Control Relay Model No SU 01 of RB Electronics of Kirloskar

1

-

-

... More
M&L for in replacement Fault Indicator Control Relay Model No KRB 101 of RB Electronics of Kirloskar

1

-

-

... More
M&L for in replacement Temperature gauge

1

-

-

... More
M&L for in replacement Oil Pressure Gauge 0-10 Bar

1

-

-

... More
M&L for in replacement Digital Frequency meter Make -NIPPON/CONSVER

1

-

-

... More
M&L for in replacement DC Volt meter 0 to 30 volt

1

-

-

... More
M&L for in replacement DC ammeter 0 to 2 amp

1

-

-

... More
N&L for in replacement Excitation coil for DG Set15 KVA to 160 KVA DG SET

2

-

-

... More
M&L for in replacement AVR card for DG Set15 KVA to 160 KVA DG SET

2

-

-

... More
M&L for Servicing of Self Starter 12/24 Volt DC forDG Set15 KVA to 160 KVA DG Set, dismantling complete,& replacement of solenoid field coils. cleaning the commutator strips including replacing the bearing, bends pinion re-assembling, connecting and testing complete all as directed by Engineer-in-charge

1

-

-

... More
M&L for in replacement self starter 12 volt DC for DG Set15 KVA to 160 KVA DG SET including all accessories complete all as directed by Make : LUCAS or equivalent.

1

-

-

... More
M&L for in replacement oil Feed Pump for Aquastic DG SET for capacity DG Set15 KVA to 160 KVA Make -KIRLOSKAR or equivalent.

1

-

-

... More
M&L for in replacement alternator for battery charging 12/24 volt DC complete with all accessories .

1

-

-

... More
Draining out the Water from the radiator, dis-mantling the leaking radiator assembly complete from the engine body, transporting to workshop, cutting the bottom chambers, repairing the damaged pipes, brazing the leaking portions ,descaling / clearing all the blocked pipes including repairing the fins, brazing the bottom chambers, testing the radiator for leaks, transporting the same to the site and re-fixing and testing complete in the presence of Engineer-in-charge. for Capacity DG Set15 KVA to 160 KVA.

2

-

-

... More
M&L for in replacement solenoid Switch 12 Volt DC. Make: LUCAS

1

-

-

... More
M&L for in replacement Stopping relay 24 volt DC. Make:- Lucas

2

-

-

... More
M&L for in replacement Anti - Vibrating Pad suitable for DG Set15 KVA to 160 KVA DG Set.. Make:- LOVE JOY/DON LOP

2

-

-

... More
M&L for in replacement Ignition Switch for capacity up to DG Set15 KVA to 160 KVA DG SET.

1

-

-

... More
M&L for Coolant as required for top up. Make : MAX Super Cool for Acoustic DG SET.

5

-

-

... More
M&L for Refilling of distilled water for top up battery 12 volt DC.

5

-

-

... More
M&L in replacement Fuel pipes with benjo bolt and washers.For capacity DG Set15 KVA to 160 KVA DG SET.

2

-

-

... More
M&L for in replacement Heavy duty Battery terminal for 12 volt DC battery suitable AH at site.

3

-

-

... More
M&L for in replacement Radiator Hose pipe as per existing Set of 2

1

-

-

... More
M&L for inreplacmennt Door Lock Assembly with key for Acoustic DG SET.

3

-

-

... More
M&L for in replacement Heavy duty Automatic electronic battery charger suitable for 12/24 Volt DC

2

-

-

... More
M&L for in replacement Rubber Coupling with nut bolt & washer in between Alternator& Engines & DG Set15 KVA to 160 KVA DG SET

1

-

-

... More
M&L for in replacement Battery lead with lug as per existing length & size for capacity DG Set15 KVA to 160 KVA

3

-

-

... More
M&L in replacement Air Filter inside & out side for capacity DG Set15 KVA to 160 KVA

1

-

-

... More
M&L in replacement Primary Fuel Filter for capacity DG Set15 KVA to 160 KVA

5

-

-

... More
M&L in replacement Secondary Fuel Filter for capacity DG Set15 KVA to 160 KVA.

2

-

-

... More
M&L in replacement Lubricating Oil Filter for capacity DG Set15 KVA to 160 KVA.

2

-

-

... More
M&L in replacement V- Belt as per existing size for capacity DG Set15 KVA to 160 KVA

6

-

-

... More
M&L in replacement Diesel pipe PVC Flexible up to 12 mm for capacity DG Set15 KVA to 160 KVA.

2

-

-

... More
M & L in replacement of Genset controller for DG Set15 KVA to 160 KVA

1

-

-

... More
M & L in replacement Voltage Monitoring Relay(VMR)

4

-

-

... More
M & L in replacement OEN Relay

6

-

-

... More
M & L in replacement Timer for controlling voltage shifting from no load to full load complete all as specified and directed by Engr-in-charge

2

-

-

... More
M & L in replacement water pump of capacity DG Set15 KVA to 160 KVA

3

-

-

... More
M & L in replacement Coolant Hose set for DG Set15 KVA to 160 KVA

2

-

-

... More
M & L in replacement Fuel hose set for DG Set15 KVA to 160 KVA

2

-

-

... More
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for taking out/laying pipe line and getting out, in hard/dense Soil complete all as specified and directed by Engineer-in-charge.

30.24

-

-

... More
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for taking out/laying pipe line and getting out, in soft/loose Soil complete all as specified and directed by Engineer-in-charge..

88

-

-

... More
Returning, filling including spreading levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and directed by Engineer-in-charge..

25

-

-

... More
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-charge..

63

-

-

... More
Disconnecting ,dismantling and taking down of unserviceable rusted water tubing GI of size 100/80 mm from existing place in trenches/wall/floors/ceilings complete all as specified and directed by Engineer-in-Charge:

150

-

-

... More
All as per Srl Item No 113.00 above but GI of size 50 mm complete aii as specified and directed by Engineer-in-Charge.

50

-

-

... More
All as per Srl Item No 113.00 above but GI of size 40 mm complete aii as specified and directed by Engineer-in-Charge.

45

-

-

... More
All as per Srl Item No 113.00 above but GI of size 25 mm complete aii as specified and directed by Engineer-in-Charge.

35

-

-

... More
Supplying & Laying, connecting and testing GI pipe 100 mm bore medium grade including necessary fittings in trenches complete all as specified and directed by Engineer-in-charge.

40

-

-

... More
All as per Srl Item No 117.00 above here-in-before but of size 80 mm bore complete all as specified and directed by Engineer-in-charge.

110

-

-

... More
All as per Srl Item No 117.00 above here-in-before but of size 50 mm bore complete all as specified and directed by Engineer-in-charge.

50

-

-

... More
All as per Srl Item No 117.00 above here-in-before but of size 40 mm bore complete all as specified and directed by Engineer-in-charge.

45

-

-

... More
All as per Srl Item No 117.00 above here-in-before but of size 25 mm bore complete all as specified and directed by Engineer-in-charge.

35

-

-

... More
Dismantling and taking out unserviceable Sluice Valve of size 80 mm bore from line complete all as directed by Engineer-in-charge.

3

-

-

... More
Dismantling and taking out unserviceable Sluice Valve of size 100 mm bore from line complete all as directed by Engineer-in-charge.

2

-

-

... More
Supply and fix in repairs Sluice Valve Class PN 1.6 80 mm dia with iron wheel head, gaskets nuts, bolts,washers complete all as directed by Engineer-in-Charge.

3

-

-

... More
Supply and fix in repairs Sluice Valve Class PN 1.6 100 mm dia with iron wheel head, gaskets nuts, bolts,washers complete all as directed by Engineer-in-Charge.

2

-

-

... More
Dismantling and taking out unserviceable gun metal gate valve of size 50 mm to 40 mm bore from line complete all as specified and as directed by Engr - in- charge.

10

-

-

... More
Dismantling and taking out unserviceable gun metal gate valve/stop valve of size 25 mm to 20 mm complete all as specified and as directed.

5

-

-

... More
Supply and fix gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe of sizes 50 mm dia complete all as specified and as directed by Engineer - in-Charge:

5

-

-

... More
Supply and fix gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe of sizes 40 mm dia complete all as specified and as directed by Engineer - in-Charge:

5

-

-

... More
Supply and fix gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe of sizes 25 mm dia complete all as specified and as directed by Engineer - in-Charge:

5

-

-

... More
Supply and fix gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe of sizes 20 mm dia complete all as specified and as directed by Engineer - in-Charge:

3

-

-

... More
Dismantling damage and broken valve chamber of size 1200x1200x900mm including unserviceable rusted MS cover complete without disturbing the existing pipe lines valves and provide valve chamber including necessary earth work in any type of soil PCC 1:1.5:3 in base concrete brick work in CM (1:6) with 10mm thick plaster internally and 15mm thick externally in CM (1:4) 6mm thick MS sheet cover with hinges and locking arrangements fixed to angle iron frame made out of 502x50x6mm MS complete with 2 coat of synthetic enamelled paint over a coat of red oxide on all steel work and 2 coats of white washing on plastered surface of valve chamber of any sizes complete all as specified and as directed by Engr - in- charge.

2

-

-

... More
All as per Srl Item No 132.00 above here-in-before but of size 900 mm X 900 mm X 900 mm internal complete all as specified and directed by Engineer-in-charge.

2

-

-

... More
Material and Labour for PCC (1:2:4) type B-1 for supporting pillar posts for pipes/flooring/paving / foundation for motor etc complete all as specified and directed by Engineer-in-charge.

1

-

-

... More
Material and Labour for brick work with subclass B bricks in cement mortar 1 : 4 , straight or curved on plan exc 6m mean radius built in including taking down unserviceable bricks complete all as specified and directed by Engineer-in-charge.

1

-

-

... More
Material and Labour for cutting bituminous surfaces road to a depth of n exc 60cm and not exceeding 60cm in width for taking out or laying of GI tubing and refilling the same with necessary making good works complete all as specified and as directed by Engineer-in-charge

0.5

-

-

... More
Demolition and dismantling of Cement concrete of any description and in any position and removing the materials to a distance not exceeding 100 m all as directed by Engr in Charge

0.5

-

-

... More
Material. fabricated, and erecting for base frame / Iron Ladder/Duct covers of UG Tank / OH Tank for centrifugal pump set fabricated out of structural steel sections such as joint, channel, angle, or tee sections including grouting nuts bolts, washers , checknuts etc and painting the frame with two coats of rust proof paint over a coat of zinc primer including dismantling and taking down rusted steel items from existing places complete all as directed by Engr-in-Charge

43.5

-

-

... More
Disconnecting, dismantling and taking out after disconnecting of incoming and outgoing water & electric connections & transportation to work shop of 3 to 5 HP pumping set for repairs/ rewinding.Dismantling the pump set complete, separating the parts such as rotor, impellar,bearing, shaft seal, shaft cleaning of all dismantled parts, dismantling the motor and cutting & removing burnt winding from slot cleaning the slots , packing the slots with insulated packing material, rewinding with super enamelled copper winding wire of same gauge varnishing the stator & drying in oven reassembling the pump set complete with and including new packing material, gland packing , stud, new set of bearings, terminal plate, transporting back to plant room, refixing on foundation connecting up and testing complete all as directed by Engineer-in-charge

2

-

-

... More
All as per Srl Item No 139.00 above herein but for motor of capacity 7.5 HP complete all as directed by Engineer-in-charge

3

-

-

... More
Supply and fixing in repairs fully automatic DOL starter suitable for 3 to 5 HP Pumping set 415 volts 3 phase as existing in panel board including taking down existing starter complete all as specified and directed .Make “Siemens / L&T / Bhartiya Cutler Hammer ”

2

-

-

... More
Supply and fixing in repairs fully automatic DOL starter suitable for 7.5 HP Pumping set 415 volts 3 phase as existing in panel board including taking down existing starter complete all as specified and directed .Make “Siemens / L&T / Bhartiya Cutler Hammer ”

2

-

-

... More
Supply and fixing in repairs Contactor ML-3 3 Pole with DC Coil suitable for 3 to 5 HP 415 volts 3 phase motor including taking down existing contactors complete all as directed by Engineer-in.-charge

2

-

-

... More
Supply and fixing in repairs Contactor ML-3 3 Pole with DC Coil suitable for 7.5 HP 415 volts 3 phase motor including taking down existing contactors complete all as directed by Engineer-in-charge.

2

-

-

... More
S & F in repairs Single Phase Preventer for motor protection Circuit Breaker up to 7.5 HP Motor including taking down existing.

1

-

-

... More
Supply and Fix foot valve of Brass of Size 80 MM Dia complete all as specified and Directed by Engr-in-Charge.

4

-

-

... More
Cleaning of RCC UG sumps of 10000 Gallon capacities by involving of the followings 08(Eight) stage of cleaning process complete all as specified and directed (i) De-watering by high pressure submersible pump all complete (ii) Removal of sludge from sump (iii) Cleaning of walls, floors, ceiling etc complete (iv) Removing dirt and sludge by vacuum pump (v) Anti- Bacterial Treatment of inside of tank which effective against all pathogens all complete. (vi) Applying one coat of white wash internal surfaces. (vii) Replace nylon net for vent pipes & man hole cover (viii) Writing letter in bold with white paint on black colour back ground such as sump number, capacity, cleaned on Date & Due on Date etc Note :- The tenderer shall take into consideration for following points while quoting his rate for this item and the unite rate is deemed be included for :- (i) The contractor shall be provide dewatering pump of suitable capacity. The rate is inclusive of rent/hiring charge complete. (ii) Cutting and filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level. Useful material shall be stacked. (iii) Material removed from the tank shall be disposed all as per direction of Engineer-in-charge. (iv) Tank shall be made available for cleaning for a period of 8 hours only and contractor has to arrange sufficient labour/ T&P to complete the job with the given period only. or otherwise penalty shall be imposed @ Rs 1000/- per day. (iv) All safety with Gadgets like Safety Belts, Special Safety Ladder, Helmets, Heavy Duty Gum Boots, Gloves, Safety Goggles, Masks, Aprons, etc. for complete security the safe operations. Storage and Cleaning equipment’s like Scrubbers/Wipers, Storage drums, Sludge Collectors and Cisterns, etc. must be integral part of system.

4

-

-

... More
Cleaning of RCC UG sumps of 7500/7000 Gallon capacities by involving of the followings 08(Eight) stage of cleaning process complete all as specified and directed (i) De-watering by high pressure submersible pump all complete (ii) Removal of sludge from sump (iii) Cleaning of walls, floors, ceiling etc complete (iv) Removing dirt and sludge by vacuum pump (v) Anti- Bacterial Treatment of inside of tank which effective against all pathogens all complete. (vi) Applying one coat of white wash internal surfaces. (vii) Replace nylon net for vent pipes & man hole cover (viii) Writing letter in bold with white paint on black colour back ground such as sump number, capacity, cleaned on Date & Due on Date etc Note :- The tenderer shall take into consideration for following points while quoting his rate for this item and the unite rate is deemed be included for :- (i) The contractor shall be provide dewatering pump of suitable capacity. The rate is inclusive of rent/hiring charge complete. (ii) Cutting and filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level. Useful material shall be stacked. (iii) Material removed from the tank shall be disposed all as per direction of Engineer-in-charge. (iv) Tank shall be made available for cleaning for a period of 8 hours only and contractor has to arrange sufficient labour/ T&P to complete the job with the given period only. or otherwise penalty shall be imposed @ Rs 1000/- per day.

1

-

-

... More
Cleaning of RCC Over Head Tanks of 15000/20000 Gallon capacities by involving of the followings 07(SEVEN) stage of cleaning process complete all as specified and directed (i) De-watering by all complete (ii) Removal of sludge from RCC Over Head Tanks (iii) Cleaning of walls, floors, ceiling etc all complete (iv) Removing dirt and sludge by vacuum pump (v) Applying one coat of white wash internal surfaces. (vi) Replace nylon net for vent pipes & man hole cover (vii) Writing letter in bold with white paint on black colour back ground such as sump number, capacity, cleaned on Date & Due on Date etc Note:- The tenderer shall take into consideration for following points while quoting his rate for this item and the unite rate is deemed be included for :- (i) Cutting and filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level. Useful material shall be stacked. (ii) Material removed from the tank shall be disposed off at out side. (iii) Tank shall be made available for cleaning for a period of 8 hours only and contractor has to arrange sufficient labour/ T&P to complete the job with the given period only. or otherwise penalty shall be imposed @ Rs 1000/- per day. (iv) All safety with Gadgets like Safety Belts, Special Safety Ladder, Helmets, Heavy Duty Gum Boots, Gloves, Safety Goggles, Masks, Aprons, etc. for complete security the safe operations. Storage and Cleaning equipment’s like Scrubbers/Wipers, Storage drums, Sludge Collectors and Cisterns, etc. must be integral part of system.

1

-

-

... More
Disconnecting, dismantling and taking out after disconnecting of incoming and outgoing water & electric connections & transportation to work shop of 3 to 5 HP pumping set for repairs/ rewinding.Dismantling the pump set complete, separating the parts such as rotor, impellar,bearing, shaft seal, shaft cleaning of all dismantled parts, dismantling the motor and cutting & removing burnt winding from slot cleaning the slots , packing the slots with insulated packing material, rewinding with super enamelled copper winding wire of same gauge varnishing the stator & drying in oven reassembling the pump set complete with and including new packing material, gland packing , stud, new set of bearings, terminal plate, transporting back to plant room, refixing on foundation connecting up and testing complete all as directed by Engineer-in-charge

3

-

-

... More
All as per above here in but for motor of capacity above 5 HP to 7.5 HP complete all as directed by Engineer-in-charge

2

-

-

... More
S&F MCB distribution board double Door of sheet metal Single pole and neutral 8 way with 200 amps rated bus bar 240 volts ,complete all as specified and as directed by Engineer-in-Charge.

1

-

-

... More
S&F MCB ,SPN 240 volt 40 Amp ,complete all as specified and as directed by Engineer-in-Charge.

1

-

-

... More
S&F MCB single Pole 240 Volts 6 to 40 Amp ,complete all as specified and as directed by Engineer-in-Charge.

6

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.