Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date10 Jan 2024
Closing Date8 Feb 2024
Tender Amount₹ 14,00,000
Costs
EMD
₹ 28,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_636764_1Bid Award Id
ViewTender No
81904/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Taking down old unserviceable HT cable 11 KV of any size from trench / pole complete all as specified and directed by Engr-in-Charge.
160
-
-
M & L for Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in soft/loose soil etc complete all as specified and directed by Engr-in-Charge.
21.6
-
-
M & L for Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in hard/dense soil complete all as specified and directed by Engr-in-Charge.
10.8
-
-
M & L for Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in soft disintegrated rock complete all as specified and directed by Engr-in-Charge.
10.8
-
-
M & L for Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed by Engr-in-Charge.
25
-
-
M & L for Removing excavated material n.exc 50m and depositing where directed at a level exc. 1.5 cm above the starting point complete all as specified and directed by Engr-in-Charge.
18
-
-
M&L for crushed stone sand cushioning to UG cable, provide with the layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable complete all as specified and directed by Engr-in-Charge.
13
-
-
Supplying and laying unreinforced precast concrete cable cover, class HV, type 1 flat of size 300mm x180mm x 40mm placed perpendicular to the cable complete all as specified and directed by Engr-in-Charge.
889
-
-
Supply and fix GI Pipe Light grade with all connected accessories of sizes 100 mm dia complete all as specified and directed by Engr-in-Charge.
18
-
-
M & L for Cutting of existing road not exc 1.5 mtr in depth and not exceeding 1.5 mtr wide including black top, sub base and WBM refilling, well ramming in layers with watering after laying of RCC /GI pipe under road making good with PCC 1:2:4in all respect to match with the existing surface all as directed by E-in-charge.
18
-
-
S&F in repairs cable end joint kit 95 Sqmm, 3 core XLPE 11kV HT Cable heat shrinkable indoor / outdoor type, complete all as specified and directed by Engr-in-Charge.
6
-
-
S&F in repairs cable end joint kit 120 to 185 Sqmm, 3 core XLPE 11kV HT Cable heat shrinkable indoor / outdoor type complete all as specified and directed by Engr-in-Charge.
3
-
-
S&F in repairs cable straight through joint kit 95 Sqmm, 3 core XLPE 11KV HT Cable heat shrinkable complete including necessary excavation and earth work complete all as specified and directed by Engr-in-Charge.
6
-
-
S&F in repairs cable straight through joint kit 120 to 185 Sqmm 3 core XLPE 11KV HT Cable heat shrinkable complete including necessary excavation and earth work complete all as specified and directed by Engr-in-Charge.
4
-
-
M&L for services for cable fault location for 11 kV, 3core XLPE Cable 95 sqmm to 185 sqmm with the help of 22kV HT fault detector machine complete all as specified and directed by Engr-in-Charge. Note: Contractor shall depute his staff along with fault locating machine within 8 hours of intimation.
15
-
-
Taking out the HT 11 KV metalclad Vaccum circuit breaker of rating 400A, 11000 volts,3 ph, 50 Hz, 250 MVA of any make and type from the cubical panel, for repairs/overhauling and servicing including replacement of wornout parts comprising the following works.
(a) Removing the complete fixed contacts, moving contacts, cleaninig the contacts,removing the fittings and fixing back to the breakers after adjusting the pressure
(b) Checking charging motor, motor relay, anti pump relay of the breaker, lubricate and align properly for smooth and perfect operation
(c) check and service the operating mechanism closing mechanism, and tripping mechanism including spring pressure, position etc
(d) checking, setting of the movement of the trolly of breaker lubricate it adjust the stopper bolt/lever for proper functioning of the breaker
(e) check the auxilliary switch, shunt trip assembly, closing / Trip solenoid, limit switch and complete contol wiring of the breaker and repair the same for effective functioning of the breaker
(f)Testing of IR value with the help of meggar and commissioning the HT vaccum circuit breaker all as specified and as directed by Engr-in-charge
Note:- VCB spares shall be measured and paid seperatly under relevent item. However other than mentioned spares in this schedule if required for smooth functioning of VCB, cost of the spares deemed to be included in quoted rates complete all as specified and directed by Engineer-in-Charge
40
-
-
Supply only moving contact to the vacuum circuit breaker of Capacity 400 Amp, 3 phase, 11000 volts, 250 MVA complete all as specified and directed by Engr-in-Charge (all as per exsisting make and type)
2
-
-
Supply only fixed contact to the vacuum circuit breaker of Capacity 400 Amp, 3 phase, 11000 volts, 250 MVA complete all as specified and directed by Engr-in-Charge (all as per exsisting make and type)
2
-
-
Supply only Arc shield to the vacuum circuit breaker of Capacity 400 Amp, 3 phase, 11000 volts, 250 MVA complete all as specified and directed by Engr-in-Charge (all as per exsisting make and type)
2
-
-
Supply only spring charging motor to the vacuum circuit breaker of capacity 400 Amp, 3 phase, 11000 volts, 250 MVA complete all as specified and directed by Engr-in-Charge (all as per exsisting make and type)
2
-
-
Supply only auxiliary switch to the vaccum circuit breaker of Capacity 400 Amp, 3 phase, 11000 volts, 250 MVA complete all as specified and directed by Engr-in-Charge. (all as per exsisting make and type)
2
-
-
Supply only latch switch assembly to the vaccum circuit breaker of Capacity 400 Amps, 3 phase, 11000 volts, 250 MVA complete all as specified and directed by Engr-in-Charge (all as per exsisting make and type)
2
-
-
Supply only closing soleniod coil to the vacuum circuit breaker of Capacity 400 Amps, 250 MVA, 3 phase, 11000 volts, complete all as specified and directed by Engr-in-Charge (all as per exsisting make and type)
2
-
-
Supply only loading spring to the vacuum circuit breaker of Capacity 400 Amps, 250 MVA, 11000 volts, complete all as specified and directed by Engr-in-Charge (all as per exsisting make and type)
2
-
-
M&L for servicing and testing of secondary injection of over current and earth fault relay of HT VCB/OCB 11 kV panel on each multiple setting , readjustment and calibration the same complete, checking of control wiring including testing on completion complete all as specified and directed by Engr-in-Charge.
2
-
-
M&L for servicing and testing of primary injection by artificial load through CTs on each multiple setting of over current and earth fault relay of HT VCB/OCB 11 kV, testing CTs polarities , relay calibration, cordination of relays complete and checking of control wiring including testing on completion complete all as specified and directed by Engr-in-Charge.
2
-
-
S&F in repairs neon indication lamps assembled for HT 11 KV cubical complete all as specified and directed by Engr-in-Charge.
4
-
-
M&L for replacement of HT voltmeter digital type 0 to 15 KV (PTR 11 KV/ 110 Volt) , complete all as specified and directed by Engr-in-Charge. (As per existing)
2
-
-
M&L fo replacement of HT Ammeter Digital type 0 to 60 Amps. complete all as specified and directed by Engr-in-Charge.(As per existing).
2
-
-
M& L for replacement of defective current transformer resin casted two core double ratio ( one for protection and other core for metering equipment), class 1.0, 100 Amps, as per existing CT ratio and model, for 11 kV of VCB complete all as specified and directed by Engr-in-Charge.
1
-
-
M&L for replacement of unserviceable HRC cartige fuse of existing capacity make suitable for HT VCB 11 kV complete all as specified and directed by Engr-in-Charge.of Crompton/MEI make all as directed.
1
-
-
Taking out old unservicable battery back up from HT 11 kV OCB/VCB panel, S & Fix new batterry back up with maintenance free sealed lead Acid Battery suitable size complete as per exsisting or equivalent model and testing complete all as specified and directed by Engr-in-Charge.
2
-
-
M&L for filtration of transformer oil to remove moisture, sludge, carbon particles and to achieve dielectric strength/rupturing capacity of oil and topping up of oil to the required level of the transformer indicator level complete all as specified and directed by Engr-in-Charge.
Note: (a) Oil topping up shall be measured and paid separately.
(b) Filtration shall be done at site and on line.
(c) BDV test shall be carried out before the filtration and after the filtration & results recorded in triplicate duly signed by the contractor, MES rep. and Engr-in-charge (d) Dielectric strength of the oil shall not be less than 50 kV after filtration & the rate quoted for the items shall be deemed to include the filtration till the desired dielectric strength is achieved complete all as specified and directed by Engineer in Charge
1500
-
-
Supply and Fill new transformer oil topping up / change complete superior quality having di - electric strength not less than 60 KV and ISI marked of approved make complete all as specified and directed by Engr-in-Charge.
Note: (a) The transformer oil shall be ISI marked, and brought at site in sealed container only.
(b) Cost of collection of samples before and after topping up/changing including testing for dielectric strength etc complete included in the rate quoted for this item
800
-
-
Disconnecting the transformer any type situated at various locations 11/ 0.433 KV of any make and transporting to workshop for repairs/ rewinding. Dismantling the transformer and accessories, draining out insulating oil, taking out the core assembly, defective winding, cleaning the transformer complete internally and externally, rewinding burnt HT/LT coil with existing guage of copper super enameled wire / copper strip of exsisting size, providing new insulation, sleeves for outlet connections, heating the complete core assembly, reassembling, including dehydration and filtration of Transformer oil to achieve desired dielectric strength, carrying out routine test, re-installation and commissioning. The repair work also includes the routine tests i.e. IR value, High voltage test, Ratio test, Short circuit test & BD value of oil of the transformer to be carried out at workshop for following capacities of transformer 150 to 350 KVA
Note: (i) Copper winding wire/strip will be measured and paid separately.
(ii) Transformer oil for topping up will be measured and paid separately.
(iii) Transportation of transformer for repair and re-installation is deemed to include in quoted rates complete all as specified and directed by Engineer in Charge
1
-
-
Disconnecting the transformer any type situated at various locations 11/ 0.433 KV of any make and transporting to workshop for repairs/ rewinding. Dismantling the transformer and accessories, draining out insulating oil, taking out the core assembly, defective winding, cleaning the transformer complete internally and externally, rewinding burnt HT/LT coil with existing guage of copper super enamelled wire / copper strip of exsisting size, providing new insulation, sleeves for outlet connections, ovening the complete core assembly, reassembling, including dehydration and filtration of Transformer oil to achieve desired dielectric strength, carrying out routine test, re-installation and commissioning. The repair work also includes the routine tests i.e. IR value, High voltage test, Ratio test, Short circuit test & BD value of oil of the transformer to be carried out at workshop for following capacities of transformer above 350 KVA to 500 KVA
Notes (i) Copper winding wire/strip will be measured and paid separately.
(ii) Transformer oil for topping up will be measured and paid separately.
(iii) Transportation of transformer for repair and re-installation is deemed to include in quoted rates complete all as specified and directed by Engineer in Charge
1
-
-
Removal of burnt HT coil winding and replacement of the same with new copper wire coil of same gauge and turns including necessary insulation materials like impregnated paper or super enamelled of transformers of capacity 150 KVA to 500 KVA complete all as specified and directed by Engineer in Charge
100
-
-
Removal of burnt LT coil winding and replacement of the same with copper strips of same gauge and turns including necessary insulation materials of transformers of capacity 150 KVA to 500 KVA complete all as specified and directed by Engineer in Charge
100
-
-
Disconnecting the transformer any type from HT/ LT system and opening carefully for rectifying the leakage by replacing the unserviceable spare parts of capacity 50 to 630 kVA transformer and complete assembling after repairs including testing for any oil leakages, proper functioning and connecting the HT/ LT system complete all as specified and directed by Engr-in-Charge.
Note :- Defective parts replaced will be measured and paid separately
2
-
-
Supply and fix in repair of LT bushings with brass studs complete all as specified and directed by Engr-in-Charge
4
-
-
Supply and fix in repair of top cover gasket set complete all as specified and directed by Engr-in-Charge
2
-
-
Supply and fix in repair of radiator flanged gasket 6mm thick complete all as specified and directed by Engr-in-Charge.
2
-
-
Supply and fix in repair of oil level indicator gasket set complete all as specified and directed by Engr-in-Charge
2
-
-
Supply and fix in repair of HT bushing with brass studs 11 KV complete all as specified and directed by Engr-in-Charge.
3
-
-
Supply and fix in replacement of breather assembly transparent plastic body with top and bottom portion pressed with metallic cover, filled with silica gel blue in colour and suitable for fixing on existing pipe of size 15/20/25 mm dia with suitable reducers/connectors etc as per site requirement /capacity of transformer complete all as specified and directed by Engr-in-Charge.
4
-
-
Supply and fix in repair of HT 11 KV terminal rod of suitable size for the transformer of 50KVA to 315 KVA rating complete all as specified and directed by Engr-in-Charge.
1
-
-
Supply and fix in repair of HT 11 KV terminal rod of suitable size for the transformer of 400KVA to 650KVA complete all as specified and directed by Engr-in-Charge.
1
-
-
Material and labour for painting of the transformer (50 to 150 KVA) complete by removing old paint by scrapping and providing spray painting with synthetic enamel paint of approved make duly marking/writing MES/SM No. complete all as specified and directed by Engr-in-Charge.
1
-
-
Material and labour for painting of the transformer (150 to 350 KVA) complete by removing old paint by scrapping and providing spray painting with synthetic enamel paint of approved make duly marking/writing MES/SM No. complete all as specified and directed by Engr-in-Charge.
1
-
-
Material and labour for painting of the tranformer (350 to 630 KVA) complete by removing old paint by scrapping and providing spray paiting with synthetic enamel paint of approved make duly marking/writing MES/SM No complete all as specified and directed by Engr-in-Charge.
1
-
-
M&L for dismantling of air break gang operated switches/drop out fuse units vertical/horizontal mounted including insulators and operating mechanism for repair/ replacement of broken/worn out components and insulators etc. complete all as specified and directed by Engr-in-Charge.
3
-
-
Supply and fixing in repairs of gang operated air break switches HT 11KV grade outdoor type, triple pole of capacity 200 amps rating mounted on polymer based 09 insulators fitted on steel frame horizontally, mechanically operated mechanism from ground level including GI pipe handle clamps bolts, nuts, jumper wire connecting with stranded conductors complete with locking arrangements complete all as specified and directed by Engr-in-Charge..
3
-
-
Supply and fix in replacement of drop out fuse unit expulsion type for outdoor air break gang operated switch, single pole, mounted on polymer based insulators for 11 KV working pressure, fixed to and including MS channel with nuts, bolts, washers etc, synthetic bounded fuse carrying tube complete with line taps and suitable for current carrying capacity upto 25-50Amps and connected with suitable size of ACSR conductor as jumper between GOD and DO fuse, with 11 KV HT PVC sleeve, with all fittings/accessories etc, including taking down of only 3 fuses complete all as specified and as directed by Engr-in-charge.
2
-
-
Supply, fixing and connecting in repairs HT 11 KV outdoor expulsion type lightning arrestors with mounting accessories complete fixed on cross arms of 2 pole structur and connected with same size of ACSR conductor as O/H HT conductor with 11 KV KT empire tape insulation with all fittings, transmission class, having discharged capacity of 65 kilo amps and suitable for working pressure of HT 11 KV complete all as specified and directed by Engr-in-Charge
1
-
-
S&F in repair disc insulator porcelain vitreous brown 145 mm high and 255 mm dia ball and socket type two in series assembly with cast aluminium 4 U bolt tension hardeare and tension clamps for conductors working pressure HT 11 KV complete all as specified and directed by Engr-in-Charge.
3
-
-
S&F for aluminium tubing heavy duty of size 32mm outer dia, 20mm inner dia, 06 mm thick with necessary clamps, bolts nuts and washers of suitable size, mounted on polymer based 11 KV insulators connection with jumpers including removal of unserviceable one complete all as specified and directed
20
-
-
S&F for aluminium strip of size 32mm x 10mm thick with necessary clamps, bolts nuts and washers of suitable size, mounted on polymer based 11 KV insulators with jumpers including removal of unserviceable one complete all as specified and directed
40
-
-
M&L for cement concrete(1:4:8) type D2 in foundation filing and mass concrete using 40 mm graded stone aggregate for pole/ path way foundation or as required on site etc complete all as specified and directed by Engr-in-Charge
0.5
-
-
M&L for cement concrete (1:3:6) type C2 in foundation filling and mass concrete using 40 mm graded stone agg for pole/ path way foundation or as required on site complete all as specified and directed by Engr-in-Charge
0.5
-
-
M&L for cement concrete (1:2:4) type B1 in foundation filling and mass concrete and coping of poles incl necessary form work using 20 mm graded stone agg etc complete all as specified and directed by Engr-in-Charge
0.5
-
-
Materials and labour for cross arms, bracings supports clamps and back plates fabricated from structural steel section including nuts bolts, washers welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of two quotes of aluminium paint/Emulson over a coat of red oxide zinc chrome primer complete all as specified and directed by Engr-in-Charge
1
-
-
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm as earthing lead buried directly in groungd vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to and including galvanised iron strip 32 X 6 mm as earthing lead by means of bolts, nuts, checknuts and washers etc made of GI and connected earthing test points all as shown in electrical plate no. 5 of SSR Part-1 of 2009.00 and as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm) funnel with grade and lugs, including galvanised iron strip 32 X 6 m with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified and directed by Engr-in-Charge
3
-
-
M&L for HT jumper with the help of Aluminium Conductor Steel Re-inforcement covered with insulating material/sleeve and including lugs at both ends at suitable at site. The length of jumper shall not be less that 2.5 meter including connection with the help of connector on the HT pole complete all as specified and directed by Engr-in-charge.
10
-
-
S&F in repair numerical type 3 over current earth fault relay , front USB Communication, 3 relay outputs, fault records-10, fixed design, non-draw out 1A/5A complete all as specified and directed by Engr-in-charge.
2
-
-
S&F Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed by Engr-in-charge.
2
-
-
S&F Danger sign board sticker suitable for 11000 volts of size 300 x 300 mm with letters, figures and conventional skull and bones in signal red colour and fix on HT feeder pillar box/Panel complete all as specified and directed by Engr-in-charge.
4
-
-
S&F Location sign board sticker size 500x200 mm with letters in white colour on blue background as required and fix on HT feeder pillar box/Panel complete all as specified and directed by Engr-in-charge.
18
-
-
Material and labour for painting to existing HT 2 pole structure 11 mtr long including cross arms/angle etc. with one coat of aluminium paint including preparation of surfaces with new feeder name plate with zebra type painting upto 6 feet from bottom with alternate patch of size 1 foot of white and light blue colour paint complete all as specified and directed by Engr-in-charge.
6
-
-
Material and labour for painting to existing HT 4 pole structure 11 mtr long including cross arms/angle etc. with one coat of aluminium paint including preparation of surfaces with new feeder name plate with zebra type painting upto 6 feet from bottom with alternate patch of size 1 foot of white and light blue colour paint complete all as specified and directed by Engr-in-charge.
3
-
-
Material & Labour for painting to HT feeder pillar box panel & duct cover etc, including angle iron frame with two coat of fire red synthetic enamel paint including door welding with hinge complete all as specified and directed by Engr-in-Charge.
4
-
-
M&L for cleaning of out door sub station/ HT feeder pillar box/ two/four/six pole structure by cutting and removing vegetation growth and surface leveling and removing debris and depositing to a distance not more than 50 mtr complete all as specified and directed by Engr-in-Charge. Note : Cleaning of Area may measured and paid more than one time in contract period as required as required on site
2000
-
-
Supply in replacement of old/unserviceable female/fix contact jaw for GOD swtich 11KV 400Amp.
3
-
-
Supply in replacement of copper flexible jumper 400 Amp for GOD 11KV
3
-
-
Supply and loose filling stone Aggregate of gauge 40 to 80 mm grade in Two pole/4 pole electrical sub stn area complete all as specified and directed by Engr-in-charge.
5
-
-
M & L for replacement of earthing continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/piope or fixed to poles or any other indicated situation for loop earting etc as required 32x6 mm galvanised iron strip .
12
-
-
M& L for mouisture proof painting using anti tracking paint inside HT 11 KV breakers incl CT / PT chamber etc in any kind of HT Breaker complete all as specified and directed by Engr-in-charge
3
-
-
S & F bus bar sleaves suitable for HT breakers 11 KV breaker bus bar complete all as specified and directed by Engr-in-charge
3
-
-
S & filling good quality silcagel suitable for HT 11 KV Transformers breathers as required on site complete all as specified and directed.
25
-
-
Machinary and labour for services to remove mouisture from cables/ breakers by applying highpot testing for 11 kV 3core XLPE Cable 95 sqmm to 185 sqmm cables /breakers as required on site with the help of 22kV / 11 KV HT highpot testing machine complete all as specified and directed by Engr-in-Charge.
15
-
-
Taking out carefully old serviceable HT UG cable 11 KV of any size from trench / pole /cable duct etc as required on site and rerouting as required on site at sub stn complete all as specified and directed by Engr-in-Charge. Note : Earth work shall be measured and paid seprately under respective item
100
-
-
S& F of room heater 1200 watt, with 3 no 400 watt heating element halogen type, plastic body with 15 amp plug top including earthing lead and 3 modes of operation complete all as specified and directed by engr-in -charge.
3
-
-
Taking proper shutdown of HT feeder from concerned power house checking, testing and locating faults of HT OH line/ under ground cable including four / two pole structure, HT feeder pillars etc. Opening/ disconnrcting HT electric connectios, removal of old jumpers by cutting of old rusted nuts, bolts & washers etc . Repair/ maint of HT GODs on four/ two pole stucture by providing new lugs of suitable size including new nuts ,bolts & washers etc. Repair to operating mechanism of 11 KV air break gang operating capacity 200/400 Amps with necessary oiling/greasing to moving parts and to set right the alignment of Male/Female contacts for proper working, heating of HT feeder pillar for demoisturising the HT end joints, bus bar and epoxy insulators including making HT feeder serviceable as and when required complete all as specified and directed by Engineer-in-Charge.
10
-
-