Military Engineer Services Tender

... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date8 Feb 2025
Closing Soon6 Mar 2025
Tender Amount₹ 42,30,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for rendering 10mm thick CM 1:4 on brickwork or concrete surface of walls and rough cast plaster in whike under coat is in plastic state in the ratio 1:1:1(1 part fine gravel of size between 6 to 12mm, 1 part cement, 1 part coarse sand), and finished even, complete all as specified and directed by Engineer-in-Charge.

140

-

-

... More
M&L for rendering 10mm thick CM 1:3 on fair faces of concrete surface and finised surfaces even and smooth without using extra cement ,complete all as specified and directed by Engineer-in-Charge.

80

-

-

... More
Supply only liquid water proofing compound ,complete all as specified and directed by Engineer-in-Charge.

60

-

-

... More
Removal of existing concrete including loose/weak concrete from the concrete structure i.e. beams/ columns/ deckslab etc upto beyond corroded steel reinforcements to a depth of minimum 10mm minimum behind the reinforcement by chipping/hacking with chisel and hammer or by mechanical means like chisel hammer, pneumatic chippers including high pressure water jetting and removal of debris. Concrete around the corroded reinforcement shall be removed properly. The edges of the repair locations of concrete should be saw cut to depth of at least 10mm to avoid featheredging and to provide a square edge complete all as specified and directed by Engr-in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.

70

-

-

... More
M&L for Preparation of surface and removal of rust in the loosely bonded concrete of the RCC deckslab, beam / girder and piles shall be chipped out using the mechanical cutter exposing the bars and applying Rust Remover using small brush and allow to react it for 16-24 hrs. Before applying protective coating,the surface should be wire brushed and thoroughly cleaned for dust with dry cloth complete all as per manufacturer instructions and directed by Engr- in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.

70

-

-

... More
M&L for applying two coats of Anti-Corrosive Primer two component (epoxy anticorrosive zinc rich coating) on reinforcement steel surfaces uniformely. Coating shall be applied by the brush to the exposed and cleaned rebars with an interval of 45 minutes to 1 hour @ 40microns DFT / coat and allowed to completely dry for 24 hours complete all as per manufacturer instructions and directed by Engr- in-Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.

70

-

-

... More
M&L preparation of concrete surfaces by removing loose concrete, dust, dirt etc, cleaning the surface properly and applying one liberal coat of epoxy bonding agent ( two component agent) by brush application complete all as per manufacturer instruction, complete all as specified and directed by Engineer-in-Charge. . Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.

70

-

-

... More
M&L for 50mm thick polymer modified mortar ( average thickness) modified single component, alkaline resistant fibre reinforced, thixotropic, cementitious patch repair mortar on conrete structure. Applying the mortar arround the reinforcement and finishing to bring it in line with existing concrete surface complete all as per manufacturer instructions and directed by the Engr-in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.

70

-

-

... More
M&L for holes of dia 16mm and depth 100 mm drilled @ a spacing of 1mtr c/c both ways on the existing structure .The loose cementitious particles are removed using a air blower to clean the holes.Shear Keys of dia 10mm cut from HYSD rebars are anchored into these holes of depth 75mm and bent out to an equal length of 75mm using Resin Anchor Grout complete all as per manufacturer instructions and directed by the Engr-in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.

20

-

-

... More
M&L for Providing & executing injection/pressure grouting in the cracks in the parent concrete by fixing PVC/Aluminium nipples at 150mm to 200mm distance or specified distances as per design and detailed specifications. Pressure grouting using low viscous epoxy grout. Moisture insensitive epoxy resin injection material supplied in 1.5 Litre pack which can grout gaps ranging from 0.25mm to 9mm, having mix density 1060 Kg/m3, compressive strength 60 N/mm2, Tensile Strength 20 N/mm2, Flutural strength 45 N/mm2. Pressure grouting shall be carried out after surface preperations includes fixing nipples and filling cracks with epoxy mortar one day before grouting, injecting low viscous grout mechanically about pressure 3.5-7.0 Kg/Cm2, removing nipple after grouting and sealing with epoxy mortar etc complete as directed by Engr - in - Charge. Payment shall be made on actual grout consumed. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.

6

-

-

... More
M&L for micro concrete to existing concrete structure including proper tight leak proof shuttering SPL polimer modified cementitious ,low permeable'free flow 'non shrink 'self compacting micro concrete shall be grade M70 as per recommended w/c ratio and pouring as per the required thickness complete all as per manufacturer instructions and directed by Engr- in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.

0.5

-

-

... More
M&L for Cutting, fabricating new reinforcement Fe500 and fixing with old existing reinforcement which was reduced to 20% or more of its original diameter as provided in original structure and additional steels as directed by EIC to be fixed with chemical anchor grout Lokfix E55 (Styrene free vinyl-ester resin based catridge system for anchoring reinforcement supplied in 300 ml catridge with a single mixer nozzle of Fosroc or equivalent approved make, application includes drilling hole close to old reinforcement bar with suitable drill as per dia of bar, cleaning the hole with wire brush and compressed air, putting Lokfix E55 or equivalent with gun followed by placing rebar with slide rotational motion to avoid air void formation etc complete all as per manufacturer instructions,complete all as specified and directed by Engineer-in-Charge. and as directed by the Engr-in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.

30

-

-

... More
M&L for preparation of new plastered or unplastered surfaces of walls including scrapping and applying two coats of distemper oil emulsion over a coat of 1mm thick wall care putty, complete all as specified and directed by Engineer-in-Charge.

350

-

-

... More
M&L for Preparation of new plastered surfaces of wall and apply two coats of Acrylic emulsion exterior paint of required shade : (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) in camouflage pattern and upto ht of 15m from GL, complete all as specified and directed by Engineer-in-Charge.

390

-

-

... More
M&L for preparation of new plastered or unplastered surfaces of ceiling and apply two coats of distemper oil emulsion over a coat of 1mm thick wall care putty, complete all as specified and directed by Engineer-in-Charge.

80

-

-

... More
M&L for complete removal of existing treatment on old surface of walls and applying 2 coats of Oil Bound Distemper over 1 mm thick wall care putty on walls ,complete all as specified and directed by Engineer-in-Charge.

500

-

-

... More
M&L for Preparation of old wall surfaces and Fiinishing walls with Acrylic Smooth exterior paint of required shade : New work (Two coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) in camouflage pattern and upto ht of 15m from GL , complete all as specified and directed by Engineer-in-Charge.

650

-

-

... More
M&L for preparation of old plastered or unplastered surfaces of ceiling and apply one coats of distemper oil emulsion,complete all as specified and directed by Engineer-in-Charge.

60

-

-

... More
Removing existing water proofing treatment what so ever exist (except concert padding) and removing debris/ rubbish materials off the site ,complete all as specified and directed by Engineer-in-Charge.

300

-

-

... More
M&L for APP modified roof treatment over existing RCC roof with following specification, complete all as specified and directed by Engineer-in-Charge. :- (a) Applying bitumen primer @ 0.4 Liters/Sqm with density of 0.87 to 0.89 Kg/Liters at 25 degree C on the prepared dry roof surface. (b) Laying 3 mm thick APP membrane weight not less than 3.50 Kg/Sqm by torch application with minimum 10cm side lap and 15cm end lap. The laying of membrane shall be done through an authorised applicator of manufacturer of APP membrane.

300

-

-

... More
M&L for painting over the APP membrane with a solar reflective bituminous aluminium paint @ 0.1 Kg/Sqm prescribed by manufacturer, complete all as specified and directed by Engineer-in-Charge.

300

-

-

... More
Dismantling old Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets, complete all as specified and directed by Engineer-in-Charge.

125

-

-

... More
Supply and fix false ceiling with powder coated exposed GI grip suspension system (E-grip T-2430 of equivalent load carrying capacity with mid span deffection not exceeding 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long, cross tee 1200mm/600mm long wall angle. The main runners to be placed @ 1200mm, the cross tee 1200mm will be inserted in the pre cut slots of main runner at a regular interval of 600mm from a modular grid of 1200mm X 600mm. Additional cross less of 600mm shall be placed perpendicular to the cross tee 1200mm long to finally from a grip of 600mm X 600mm. Grip of modular size 600mm X 600mm shall be supported by 6mm dia GI wire from purlins/soffit with and including 6mm thick high pressure steam cured non asbestos fiber and fixed ,complete all as specified and directed by Engineer-in-Charge. Make : Armstrong.

125

-

-

... More
S&F for ceiling boards 600x600x15mm in size, fixed in snap grid false ceiling frame work of approved colour, type complete fixed in position,complete all as specified and directed by Engineer-in-Charge. Make : Armstrong Optra RH95/ FG Classic.

125

-

-

... More
Dismentling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed by Engineer-in-Charge.

600

-

-

... More
S&F Pre-painted Galvalume Aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws ,complete all as specified and directed by Engineer-in-Charge.

580

-

-

... More
Supply and fix Pre-painted Galvalume Aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to walls, fixed with self tapping screws ,complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
Dismantling wrought iron or mild steel work of any description not otherwise provided,complete all as specified and directed by Engineer-in-Charge.

19.35

-

-

... More
S&F Joist, channel, angle, or tee sections, vertical posts fixed independently, without connecting plates, etc. confirming to Fe 410- W (Gde- E-250) quality -A, complete all as specified and directed by Engineer-in-Charge.

1250

-

-

... More
S&F rolled sections as in main & cross beams , columns, hip and jack rafters , purlins where connected to common rafters and running rails & any other places with angles cleats or other connected plates, wind ties etc confirming to Fe 410 -W (Gde-E-250) quality A, complete all as specified and directed by Engineer-in-Charge.

685

-

-

... More
S&F plates (plain or chequered ) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attahment, confirming to Fe 410 -W (Gde-E-250) quality A,complete all as specified and directed by Engineer-in-Charge.

70

-

-

... More
S&F Hand rails, half round or other steel section , for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts &struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets ( for securing wire mesh), complete all as specified and directed by Engineer-in-Charge.

200

-

-

... More
Dismantling timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section, in any position, complete all as specified and directed by Engineer-in-Charge.

55

-

-

... More
Excavating in post holes (or similar holes) each n exc 0.5cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
M&L for cement concrete in foundations, filling and mass concrete type B2 1:2:4 , complete all as specified and directed by Engineer-in-Charge.

0.4

-

-

... More
M&L preparation of new Steel surface synthetic enamel paint of two coats in any description, over 10 cm in width or girth, not otherwise described, over a coat of Red oxide, zinc chrome, complete all as specified and directed by Engineer-in-Charge.

130

-

-

... More
M&L for Preparation of old steel surface synthetic enamel paint of one coats in any description, over 10 cm in width or girth, not otherwise described,complete all as specified and directed by Engineer-in-Charge.

50

-

-

... More
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
M&L for brick work with sub class B bricks , straight or curved on plan exc 6m mean radius built in cement mortar 1:6,complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
Demolition of RCC in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work, complete all as specified and directed by Engineer-in-Charge.

0.23

-

-

... More
Separating, scraping and cleaning of reinforcement (Demolition of concrete measured separately),complete all as specified and directed by Engineer-in-Charge.

0.4

-

-

... More
S&F for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165, complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
Dismentling floor hearth or wall tilling including cement mortar bedding ( but not backing) ,complete all as specified and directed by Engineer-in-Charge.

450

-

-

... More
M & L for Non - skid Ceramic tiles coloured 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM (1:6) for receiving floor finishes, complete all as specified and directed by Engineer-in-Charge.

250

-

-

... More
M&L coloured non-skid ceramic tiles 7-8mm thick rectified glossy (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm in skirting etc , set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick rendering in CM (1:4), complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
M&L, Glazed ceramic tiles coloured of size 350x 250x 7 mm/ 450X 300X 7mm laid on vertical surface such as dado/skirting over cement mortar backing coat, set jointed in neat cement slurry and pointed in white or coloured cement including 15mm thick backing coat in CM 1:4 , complete all as specified and directed by Engineer-in-Charge.

200

-

-

... More
Taking up or down 15mm bore steel tubing and connections, complete all as specified and directed by Engineer-in-Charge.

30

-

-

... More
Taking up or down 20mm bore steel tubing and connections,complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
S&F 15mm bore steel water tubes, medium grade, galvanised, with all fitting and fixed complete to walls ( concealed) and ceilings or laid in floors, complete all as specified and directed by Engineer-in-Charge.

30

-

-

... More
S&F 20mm bore steel water tubes, medium grade, galvanised, with all fitting and fixed complete to walls (concealed) and ceilings or laid in floors , complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
S&F as in repairs 20mm bore dia Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Cutting holes (superficial area n.exc 150 Sqcm) into or through brick walls built, in cement mortar and stone walls built in lime mortar or walls of lime concrete. and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required,complete all as specified and directed by Engineer-in-Charge. .

4

-

-

... More
S&F as in repairs Vitreous China wash down water closet pan (pedestal pattern), including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F as in repairs health faucet (ABS Body mild steel chromium plated suitable for 15mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including making connections and fixed in position,complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F in repairs of 10 ltr capaciaty PVC low level flushing cistern 10 litre capacity with 32mm bore polythene flush pipe of sufficient lenght including internal fitting (valve less syphonic) etc , complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F as in repairs Vitreous China wash basin, white, flat back, size 550 x 400mm including brackets or fixing with bolts in wall , including 15mm fancy pillar tap, waste coupling, waste pipe, complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
S&F as in repairs 15mm bore dia Bib taps, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed , complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
S&F as in repairs 15mm bore dia Stop valves, CP cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed by Engineer-in-Charge.

6

-

-

... More
S&F as in repairs Chromium plated shower roses 125mm size with or without swivel joints, any size, including fixing to steel pipe or union, complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F in repairs PVC connections 15 mm size with PTMT nuts of length 600mm fixed to GI tubing, complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
S&F as in repairs 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers,complete all as specified and directed by Engineer-in-Charge.

3

-

-

... More
S&F in repairs aluminium anodised tubular towel rail 20mm dia 600mm long including necessary aluminium brackets, complete all as specified and directed by Engineer-in-Charge.

3

-

-

... More
S&F as in repairs 75mm dia of outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as specified and directed by Engineer-in-Charge.

3

-

-

... More
Taking down rain water pipes/PVC pipes/cemented pipe (any size or pattern) including all fittings, heads, shoes, bends, swan necks, etc.,& including scaffolding, complete all as specified and directed by Engineer-in-Charge.

12

-

-

... More
S&F 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors , complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S&F 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors , complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S&F 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed on walls, complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
S&F 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed on walls, complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
S&F 110mm PVC (SWR) branch piece, single (single Y) equal or unequal provided with access door, complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S&F 75mm PVC (SWR) branch piece, single (single Y) equal or unequal provided with access door, complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S&F 75mm PVC (SWR) bends any radius provided with access door fixed to pipe , complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F 110mm PVC (SWR) bends any radius provided with access door fixed to pipe , complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F 75mm bore of PVC (SWR) vent cowl, complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S&F 110mm bore of PVC (SWR) vent cowl, complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S&F 110mm bore PVC (SWR) 'P’ trap, complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F 110mm PVC (SWR) WC connector bent type and 110mm PVC (SWR) WC connector with lip ring, complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays for 75mm bore of pipe, including bolts and nuts and securing ends of stays to wall or roof,complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
S&F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays for 110mm bore of pipe, including bolts and nuts and securing ends of stays to wall or roof, complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
Dismantling water tanks of capacity 500 ltrs & taking down from building or from staging, complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
Dismantling water tanks of capacity exc1000 ltrs but n.exc 2000ltrs & taking down from building or from staging, complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S&F Rotational moulded polyethylene water storage tanks of capacity 500 ltr (cylindrical vertical with closed top) hoisted and fixed in position and including 20mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S&F Rotational moulded polyethylene water storage tanks of capacity 500 ltr (cylindrical vertical with closed top) hoisted and fixed in position and including 20mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed ,complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
Dismantling stone slabs and tiles of any description or thickness in floors laid bedded and pointed in any mortar, complete all as specified and directed by Engineer-in-Charge.

12.4

-

-

... More
M&L for machine cut polished cuddappa stone slab 20 to 25 mm thick as in cills/jambs, cooking platform of window & door openings, set jointed and pointed in neat cement slurry with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing complete including 15mm thick backing coat in cement mortar 1:4, complete all as specified and directed by Engineer-in-Charge.

50

-

-

... More
M&L Granite (of any type) work (table rubbed and polished) 20mm thick in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite., and nosing /rounding to edges of stone slabs one edge,complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
M&L for polished Machine cut kota stone slab flooring 20-25mm thick over cement screed base in CM 1:6 15mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and directed by Engineer-in-Charge.

70

-

-

... More
S&F as in repairs sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S&F as in repairs PVC flexible wastepipe 40mm dia, 600mm long with connectors for sink, superior quality, complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
Taking down chowkats or frames with shutters ( without taking off shutters from the frame) exc 1.5 Sqm but n exc 4 sq. m each, complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
Taking down chowkats or frames with shutters ( without taking off shutters from the frame) n.exc 1.5 Sqm each, complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
Taking down shutters of any description exc 1 sqm but n.exc 2 sqm, complete all as specified and directed by Engineer-in-Charge.

3

-

-

... More
M&L for 2nd class HW Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed ,complete all as specified and directed by Engineer-in-Charge.

0.16

-

-

... More
S& F 35mm thick Flush shutters, solid core construction, with block board core andparticle board core, commercial type on both sides face is covered with decorative face veneer with lipping/frame to match, complete all as specified and directed by Engineer-in-Charge.

7

-

-

... More
M&L preparation of new wooden surface and apply two caots of synthetic enamel paint of any description, over 10 cm in width or girth, not otherwise described, over a coat of pink primer, complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS tube, supplying & fixing in opening as per specification and drawing ,complete all as specified and directed by Engineer-in-Charge.

18

-

-

... More
S&F PVC factory made wire gauged shutter with wire gauge warpped on an additional square 8mm MS solid tube and this tube shall be welded to MS tube. The wires gauge shall be stretched to tighten firmly, PVC door shutter 30mm thick (stiles) consisting of frame made out of MS tube for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm wigth stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail all as per specification and drawing given in SSR Part II, Schdule of rates 2010 and directed but as in four panels in lieu of two panels , complete all as specified and directed by Engineer-in-Charge. . Note : The wire mesh shall be measured separately.

4

-

-

... More
S&F factory made solid PVC moulded door shutter (single or double leaf) with particle board/wooden flush door core 28 to 30mm thick (stiles) with 2,4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face & 2mm prelam PVC sheet on back face, supplying & fixing in frame at site as per specification and drawing, complete all as specified and directed by Engineer-in-Charge.

5.5

-

-

... More
S&F 18mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, and including beading patti at edges fixed with screws to timber frame work, complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F 100mm size Butt hinges, stainless steel hinge heavy duty, complete all as specified and directed by Engineer-in-Charge.

33

-

-

... More
S&F 150mm long aluminium anodized barrel tower bolts of extruded section, complete all as specified and directed by Engineer-in-Charge.

8

-

-

... More
S&F 150mm extruded aluminium alloy handles fabricated type anodized complete all as specified and directed by Engineer-in-Charge.

8

-

-

... More
S & F Continuous (piano) hinges, 30mm width of flaps, mild steel, bright finish or electrogalvanised, complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
S&F 100mm long aluminium anodized barrel tower bolts of extruded section, complete all as specified and directed by Engineer-in-Charge.

14

-

-

... More
S&F 100mm extruded aluminium alloy handles fabricated type anodized, complete all as specified and directed by Engineer-in-Charge.

14

-

-

... More
S&F aluminium 75mm size Hasp and staple, safety type, including bolt to hinge plate and fixed with screws ,complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F 250mm length Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
S&F MS bands, straps, supports of stays, hold fast, wall ties etc and similar small articles etc confirming to Fe-410-/ Fe 290 gde-E250 ,complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
M&L for cutting holes in bricks walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar or cement concrete 1:2:4 type B1 as required exc half brick but not exc one brick , complete all as specified and directed by Engineer-in-Charge.

16

-

-

... More
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for chowkats/shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings , complete all as specified and directed by Engineer-in-Charge.

150

-

-

... More
S&F for ordinary sheet glass 4.8mm thick and glazing with oil putty/beddings in square exc 0.5 sq, in each panes,complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
S&F 3mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane, complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified and directed by Engineer-in-Charge.

35

-

-

... More
M&L for appling silicon sealent in gap/joint between aluminium section and cill/soffits of windows/ opeings, complete all as specified and directed by Engineer-in-Charge.

80

-

-

... More
S&F as in repairs harrison rail, mild steel, chromium plated curtain rails with fixing brackets, stops, rollers etc including brackets, complete all as specified and as directed and directed by Engineer-in-Charge.

25

-

-

... More
M&L for flat rough finished Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), complete all as specified and directed by Engineer-in-Charge.

2.25

-

-

... More
M&L for rough finished Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide , complete all as specified and directed by Engineer-in-Charge.

6

-

-

... More
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips ,complete all as specified and directed by Engineer-in-Charge.

80

-

-

... More
M&L for reinforced cement concrete type B1 (1:2:4) (nominal mix)( using 20mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed by Engineer-in-Charge.

0.28

-

-

... More
M&L for Providing precast cement concrete type B-1 (1:2:4) by using 20mm graded stone aggregate as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and set in CM 1:4, complete all as specified and directed by Engineer-in-Charge.

0.29

-

-

... More
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required, complete all as specified and directed by Engineer-in-Charge.

30

-

-

... More
S&F for 300mm bore RCC pipe class NP-2 laid and jointed complete with collers as specified including testing , complete all as specified and directed by Engineer-in-Charge.

30

-

-

... More
M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in bed to drain pipes including forming cradle after they are laid and tested for 300mm bore RCC pipe complete all as specified and as directed by Engineer-in-Charge.

30

-

-

... More
Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and directed by Engineer-in-Charge.

18.3

-

-

... More
M&L for 75mm thick cement concrete type D2 1:4:8 as in sub bases, sub floors etc , complete all as specified and directed by Engineer-in-Charge.

100

-

-

... More
M&L for coloured Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors over 15mm thick screed bed in CM 1:6, complete all as specified and directed by Engineer-in-Charge.

70

-

-

... More
M&L for 100mm thick cement concrete type B-2 1:2:4 (using 40mm graded stone aggregate) as in floors, pavings etc and finishing cement concrete surface even and smooth , and making impressions of expended metal, whilst the concrete is green, complete all as specified and directed by Engineer-in-Charge.

80

-

-

... More
M&L for providing and injecting chemical emulsion for post constructional antitermite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron, complete all as specified and directed by Engineer-in-Charge.

280

-

-

... More
M&L for providing and injecting chemical emulsion for post constructional antitermite treatment At points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same, complete all as specified and directed by Engineer-in-Charge.

120

-

-

... More
M&L for providing and injecting chemical emulsion for post constructional antitermite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors, complete all as specified and directed by Engineer-in-Charge.

400

-

-

... More
Taking down carefully point wiring and removing from site such as (Light,fan socket or power) Complete including fitting and fixtures,fan regulators switch boards,switches,ceiling rose's lamp holder from existing batten PVC conduit/steel conduit wiring complete excluding light fittings and fans all as specified and making good to the disturbed surfaces to match with existing ,complete all as specified and as directed and directed by Engineer-in-Charge.

173

-

-

... More
M & L for point wiring complete for light/ fan on independent /combine board with cable 1.5 sqmm (Nominal area) FRLSH PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC casing & caping , hooks , elbows, juction covers and junction boxes , after cutting in wall and sinking's for modular metal flush boxes suitable length and Min 1.6 mm thickness, Min 51 mm depth for mounting, switches, sockets,fan regulator with modular cover plate with frame and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth continuity conductor along with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switch and connected to common earth dolly, complete all as specified and as directed and directed by Engineer-in-Charge.

110

-

-

... More
All as as per Srl Item No 136.00 above here in before but for one socket outlet 5/6 amp on independent board, complete all as specified and as directed and directed by Engineer-in-Charge.

18

-

-

... More
All as as per Srl Item No 136.00 above here in before but for one three pin socket outlet 5 Amp on same board with other switches,complete all as specified and as directed and directed by Engineer-in-Charge.

15

-

-

... More
All as as per Srl Item No 136.00 above here in before but for one switch socket combinationt 6 pin 6/ 16 Amps on independent board with copper conductor 2.5 Sqmm ,complete all as specified and as directed and directed by Engineer-in-Charge.

25

-

-

... More
All as as per Srl Item No 136.00 above here in before but for Industrial socket with copper conductor 4.0 Sqmm ,complete all as specified and as directed and directed by Engineer-in-Charge.

5

-

-

... More
S&F Switch piano, flush type single pole, one way 5 Amp complete all as specified , complete all as specified and as directed and directed by Engineer-in-Charge.

143

-

-

... More
S&F Switch piano, flush type single pole, one way 16 Amp ,complete all as specified and as directed and directed by Engineer-in-Charge.

25

-

-

... More
S&F Socket outlet 2 in 1, 5 pin, 5A , complete all as specified and as directed and directed by Engineer-in-Charge.

33

-

-

... More
S&F Socket outlet 2 in 1, 6 pin, 6/16A flush type, complete all as specified and as directed and directed by Engineer-in-Charge.

25

-

-

... More
Supply and fix industrial socket metal clad plug and socket with MCBs single pole 20 Amp , complete all as specified and as directed and directed by Engineer-in-Charge.

5

-

-

... More
S & F stepped type,single socket fan regulator for ceiling fan 1200/1400mm sweep ,complete all as specified and as directed and directed by Engineer-in-Charge.

12

-

-

... More
S & F ceiling rose surface bakelite three terminals , complete all as specified and as directed and directed by Engineer-in-Charge.

84

-

-

... More
Taking down carefully existing serviceable LED Tubelight/ bulkhead/ security light/ recess mount fitting of any size and refixing the same to respective location after carrying out cleaning all the components of fittings, including replacement of nuts, bolts and connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector, complete all as specified and as directed and directed by Engineer-in-Charge.

15

-

-

... More
S & F in replacement LED Tubelight fitting with polycarbonate housing and integrated electronic driver, 20 watt having input voltage AC90-300V, 50 Hz , 6500K, surge protection min 4 KVA and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector, complete all as specified and as directed and directed by Engineer-in-Charge.

45

-

-

... More
S&F wall mounting fans for 230 volts single phase 400 mm sweep with complete piont wiring,switch on same board ,complete all as specified and as directed and directed by Engineer-in-Charge.

17

-

-

... More
S & F LED flood light 170 watt 230 volt AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver, lamp and fitting items , complete all as specified and as directed and directed by Engineer-in-Charge.

8

-

-

... More
Material and labour for servicing of Split type ACs of any size/capacity by disconnecting the electrical/water connections, taking out from its position, cleaning the external dirt & dust, cleaning air filter, condenser,washing by water jet,drying by air blower,checking all electrical connections and refixing in existing position and testing, complete all as specified and as directed and directed by Engineer-in-Charge.

5

-

-

... More
S&F in replacement LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and as directed and directed by Engineer-in-Charge.

13

-

-

... More
S & F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed and directed by Engineer-in-Charge.

5

-

-

... More
S & F in replacement angle holder insulated body with back plate for conduit fittings,complete all as specified and as directed and directed by Engineer-in-Charge.

5

-

-

... More
S&F LED lamp 9W for angle holder ,complete all as specified and as directed and directed by Engineer-in-Charge.

5

-

-

... More
S & F in replacement for Sub Main wiring with two single core 6 Sqmm PVC insulated FRLSH multistranded flexible copper conductor cable 660/1100 volts grade drawn in through flexible non metallic PVC casing caping conduit with and including PVC insulated 6 Sqmm multi strand copper conductor as continuous earth wire in green colour connected to common earth dolly ,complete all as specified and as directed and directed by Engineer-in-Charge. (Note : PVC cable and PVC casing caping shall be ISI marked) Note :- Two length of 6 Sqmm cable and one length of 6 Sqmm earth cable along with PVC casing caping will be measured as one running length

150

-

-

... More
S & F in replacement for Sub Main wiring with two single core 4 Sqmm PVC insulated FRLSH multistranded flexible copper conductor cable 660/1100 volts grade drawn in through flexible non metallic PVC casing caping conduit with and including PVC insulated 4 Sqmm multi strand copper conductor as continuous earth wire in green colour connected to common earth dolly ,complete all as specified and as directed and directed by Engineer-in-Charge. (Note : PVC cable and PVC casing caping shall be ISI marked) ( Make of cable - Havells/Anchor/Finolex) Note :- Two length of 4 Sqmm cable and one length of 4 Sqmm earth cable along with PVC casing caping will be measured as one running length

210

-

-

... More
S & F in replacement sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted Vertical TPN 4 ways, 415 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof , IP42 and above suitable for incorporation MCBs and isolators etc including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and as directed and directed by Engineer-in-Charge.

1

-

-

... More
S & F in replacement sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 12 ways, 240 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof, IP 42 suitable for incorporation MCBs and isolators etc including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty , complete all as specified and as directed and directed by Engineer-in-Charge.

4

-

-

... More
S & F in replacement sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 8 ways, 240 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof, IP 42 suitable for incorporation MCBs and isolators etc including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty , complete all as specified and as directed and directed by Engineer-in-Charge.

8

-

-

... More
S&F in replacement MCCB TP&N 63 Amps with breaking capcity 16kA ,Fixed TM and 415 volts AC Supply ISI marked ,complete all as specified and as directed and directed by Engineer-in-Charge.

1

-

-

... More
S & F in replacement MCB ‘B’ series type suitable for 240 volts, AC supply 6 to 32 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA ,complete all as specified and as directed and directed by Engineer-in-Charge.

12

-

-

... More
S & F in replacement MCB ‘B’ series type suitable for 240 volts,10 KA, AC supply 6 to 32 Amps , single pole (SP) with over load and short circuit protection and rupturing capacity not less than 10KA ,complete all as specified and as directed and directed by Engineer-in-Charge. (Make - Havells / Legrand / Schneider)

85

-

-

... More
Disconnecting electric connection and taking down carefully serviceable ceiling fans and deposite in MES store for safe custudy. After the building repair work or as directed refixing /hanging the ceiling fan including electric connection with and including new flexible sheathed copper wire 3 core from ceiling rose/connector to fan connector, including in replacement new nut bolts, rubber reel, capacitor 2.5mfd, machine screws and split pins etc including painting the ceiling fan complete body with blades, canopies, down rod etc. with synthetic enamel paint by spray gun after scraping down old paint in colour , complete all as specified and as directed and directed by Engineer-in-Charge.

6

-

-

... More
S&F Heavy duty metal body exahust fan of 300mm sweep ,240 volt,copper winding, complete with louvers and shutter and mounted in suitable opening arrangement in wall and connecting up including 3 core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2mm from ceiling rose to fan complete including breaking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to distubed wall in cement mortar (1 :4) white washing matching with existing colour etc. complete all as specified and as directed and directed by Engineer-in-Charge.

3

-

-

... More
S&F exhaust fan made of sturdy engineering plastic of 250mm sweep ,240 volt, complete with louvers and shutter and mounted in suitable opening arrangement in wall and connecting up including 3 core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2mm from ceiling rose to fan complete including breaking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to distubed wall in cement mortar (1 :4) white washing matching with existing colour ,complete all as specified and as directed and directed by Engineer-in-Charge.

2

-

-

... More
S&F ceiling fans AC single phase 230/240 V of size 1200 mm sweep without regulator having Min air delivery 210 CFM with service value 6.00 BEE 5 star rated with brushless direct current motor (BLDC) complete with electrical connection providing three core round flexible copper conducter cable of suitable size ,complete all as specified and as directed and directed by Engineer-in-Charge.

6

-

-

... More
Dismantling and Taking down L.T. under ground armored PVC/XLPE insulated and PVC/XLPE sheeted heavy duty 1100 Volts grade under ground cable of any size , complete all as specified and as directed and directed by Engineer-in-Charge.

193

-

-

... More
Taking out old unserviceable unreinforced precast concrete cable cover during excavation of trenches, complete all as specified and as directed and directed by Engineer-in-Charge.

900

-

-

... More
Excavation in trenches not exceeding 1.5 m wide and not exe 1.5 M in depth and getting out in hard/dense soil ,complete all as specified and as directed and directed by Engineer-in-Charge.

48

-

-

... More
Returning filling in including spreading leveling, watering and well ramming in layers not exe 25 cm each layer , complete all as specified and as directed and directed by Engineer-in-Charge.

32

-

-

... More
Removing excavated material to a distance not exe 50 M and depositing where directed not exceeding 1.50 M above the starting point ,complete all as specified and as directed and directed by Engineer-in-Charge.

14

-

-

... More
Supply and spreading in trenches clear dry sand for cable protection and punning down gently 10 cm below the cable and 15 cm above the cable , complete all as specified and as directed and directed by Engineer-in-Charge. Note :- Punning thickness only measured.

14.5

-

-

... More
Supply and laying unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 ISI marked flat size 250x150x40 mm laid in trenches , complete all as specified and as directed and directed by Engineer-in-Charge.

900

-

-

... More
M&L for cutting existing road/hard standing not exc 50x60 cm in wide & depth getting out excavated material for laying GI tube , for passing through LT cable, returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:1.5:3; including removal of surplus soil , complete all as specified and as directed and directed by Engineer-in-Charge.

30

-

-

... More
Supply and lay jointing and testing and commissioning in replacement of 35 Sqmmx4 core XLPE insulated, screened , PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/laid under roads/paths/drain/culverts or passing through pipes , complete all as specified and as directed and directed by Engineer-in-Charge.

193

-

-

... More
Material and Labour for Earthing complete with copper plate 60cm×60cm ×3.15mm thick electrode, burried directly in ground ( earth pit not less than 2.25 mtrs below ground level) with top edge of the plate not less than 1.5 mtr normal ground level, connected to 20×3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel as shown in electrical plate No 3 of MES SSR Part-I 2009 connected to earthing test point by means of copper Strip of size 20x3 mm including earthwork, PCC chamber, CI cover, GI pipe protection for strip and watering pipe, funnel, mesh etc all as required at site and all as directed. Note: (i). 7.5 RM Copper strip in deemed to be included in quoted rates beyond 7.5 RM strip shall be measured and paid separately. (ii). Earth resistance of earth pit should be less than 1.0 Ohms. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (iii) Rate quoted by the tenderer is deemed to include for salt & Charcoal upto & above 450 mm top of earthing plate,testing , complete all as specified and as directed and directed by Engineer-in-Charge.

2

-

-

... More
Supply and lay GI pipe 50 mm light grade for cable protection in walls trenches or any situation including clamp nut bolt etc , complete all as specified and as directed and directed by Engineer-in-Charge.

40

-

-

... More
M&L for steel water tubing medium grade of size 25 mm bore with all fittings laid in trenches or fixed to wall or floor, complete all as specified and as directed and directed by Engineer-in-Charge.

50

-

-

... More
M& L Cutting existing steel tubing for alterations or additions 40m or 50 mm size , Add if necessarily done in position without taking down, complete all as specified and as directed and directed by Engineer-in-Charge..

8

-

-

... More
S & F 25 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed , complete all as specified and as directed and directed by Engineer-in-Charge.

8

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.