Military Engineer Services Tender

... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date8 Feb 2025
Closing Soon27 Feb 2025
Tender Amount₹ 38,30,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and directed by Engineer-in-Charge.

22.5

-

-

... More
M&L for brick work with sub class B bricks , straight or curved on plan exc 6m mean radius built in cement mortar 1:6 , complete all as specified and directed by Engineer-in-Charge.

33

-

-

... More
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4, complete all as specified and directed by Engineer-in-Charge.

40

-

-

... More
Demolition of RCC in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work, complete all as specified and directed by Engineer-in-Charge.

3.32

-

-

... More
Separating, scraping and cleaning of reinforcement (Demolition of concrete measured separately) ,complete all as specified and directed by Engineer-in-Charge.

1.4

-

-

... More
M&L Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:4, complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
M&L for Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses, Hammer dressing with maximum depression on face from straight edge held against the dressed surface n exc. 20mm for granite or trap stone, complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
M&L for 2nd class HW Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed ,complete all as specified and directed by Engineer-in-Charge.

0.9

-

-

... More
S&F factory made single extruded WPC (Wood polymer composite ) solid plain flush door shutter of 30 mm size comprising of virgin polymer of K value 58-60 ((suspension Grade) calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk ) and non toxic additives (maximum toxicity index of 12 for 100 gms) f having minimum frame density of 650 kg/ cum, screw withdrawal strength of1800 N (Face) & 900N (Edge), minimum compressive strength of 50N/ mm2 , modules of elasticity 850N / mm2 and resistance to spread of flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, complete all as specified and directed by Engineer-in-Charge. Note :-Stainless steel butt hinges and necessary S S Screws shall be paid separately)

34

-

-

... More
S&F PVC factory made wire gauged shutter with wire gauge warped on an additional square 8mm MS solid tube and this tube shall be welded to MS tube. The wires gauge shall be stretched to tighten firmly, PVC door shutter 30mm thick (stiles) consisting of frame made out of MS tube for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail all as per specification and drawing given in SSR Part II, Schedule of rates 2010 and directed but as in four panels in lieu of two panels complete all as specified and directed by Engineer-in-Charge. Note : The wire mesh shall be measured separately.

17

-

-

... More
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples ,complete all as specified and directed by Engineer-in-Charge.

25

-

-

... More
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS tube, supplying & fixing in opening as per specification and drawing , complete all as specified and directed by Engineer-in-Charge.

24

-

-

... More
S&F factory made solid PVC moulded door shutter (single or double leaf) with particle board/wooden flush door core 28 to 30mm thick (stiles) with 2,4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face & 2mm prelam PVC sheet on back face, supplying & fixing in frame at site as per specification and drawing ,complete all as specified and directed by Engineer-in-Charge.

6.5

-

-

... More
S&F 100mm size Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 ,complete all as specified and directed by Engineer-in-Charge.

75

-

-

... More
S&F 150mm long aluminium anodized barrel tower bolts of extruded section, complete all as specified and directed by Engineer-in-Charge.

50

-

-

... More
S&F 150mm extruded aluminium alloy handles fabricated type anodized ,complete all as specified and directed by Engineer-in-Charge.

50

-

-

... More
S&F aluminium alloy anodized sliding door bolts with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts 300mm long ,complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
S&F 300mm mild steel ordinary rat tail rod pattern helical door springs including roller plate ,complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
S&F MS bands, straps, supports of stays, hold fast, wall ties etc and similar articles etc confirming to Fe -290/ Gde E-165/ Fe-410- g 310m,complete all as specified and directed by Engineer-in-Charge.

14

-

-

... More
M&L for cutting holes in bricks walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar or cement concrete 1:2:4 type B1 as required exc half brick but not exc one brick , complete all as specified and directed by Engineer-in-Charge.

80

-

-

... More
Providing cement concrete in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, complete all as specified and directed by Engineer-in-Charge.

0.4

-

-

... More
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions, complete all as specified and directed by Engineer-in-Charge.

180

-

-

... More
S&F for ordinary sheet glass 4.8mm thick and glazing with oil putty/beddings in square exc 0.5 sq, in each panes ,complete all as specified and directed by Engineer-in-Charge.

25

-

-

... More
Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified and directed by Engineer-in-Charge.

40

-

-

... More
S&F Prelaminated particle board 18/19mm thickness, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, complete all as specified and directed by Engineer-in-Charge.

40

-

-

... More
S&F Hasp and staple 100mm size mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws, complete all as specified and directed by Engineer-in-Charge.

30

-

-

... More
S&F as in repairs curtain rods mild steel, chromium plated with fixing brackets, stops, rollers etc including brackets, complete all as specified and directed by Engineer-in-Charge.

30

-

-

... More
Dismantling floor hearth or wall tilling including cement mortar bedding ( but not backing) ,complete all as specified and directed by Engineer-in-Charge.

490

-

-

... More
M & L Non - skid Ceramic tiles coloured 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM (1:6), complete all as specified and directed by Engineer-in-Charge.

250

-

-

... More
M&L for Glazed ceramic tiles coloured of size 350x 250x 7 mm/ 450X 300X 7mm laid on vertical surface such as dado/skirting over cement mortar backing coat, set jointed in neat cement slurry and pointed in white or coloured cement including 15mm thick backing coat in CM 1:4 , complete all as specified and directed by Engineer-in-Charge.

240

-

-

... More
M&L for machine cut polished cuddappa stone slab 20 to 25 mm thick as in cills/jambs, cooking platform of window & door openings, set jointed and pointed in neat cement slurry with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing complete including 15mm thick backing coat in cement mortar 1:4, complete all as specified and directed by Engineer-in-Charge.

100

-

-

... More
S&F sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, waste pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm,complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
S&F 75mm dia of outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
S&F 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors , complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
M&L for machine cut polished cuddappa stone slab 20 to 25 mm thick as in cills/jambs, cooking platform of window & door openings, set jointed and pointed in neat cement slurry with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing complete, complete all as specified and directed by Engineer-in-Charge.

15

-

-

... More
Dismantling water tanks of capacity exc 500 ltr but n.exc 1000 ltrs & taking down from building or from staging, complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
Dismantling water tanks of capacity 500 ltrs & taking down from building or from staging, complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
S&F Rotational moulded polyethylene water storage tanks of capacity 1000 ltr (cylindrical vertical with closed top) hoisted and fixed in position and including 20mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed ,complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F Rotational moulded polyethylene water storage tanks of capacity 500 ltr (cylindrical vertical with closed top) hoisted and fixed in position and including 20mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed ,complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
Disconnecting existing tanks of capacity exc 250 but n.exc 500 litres, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position after Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc ,complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
S&F as in repairs 10 ltr capacity PVC low level flushing cistern 10 litre capacity with 32mm bore polythene flush pipe of sufficient length including internal fitting (valve less syphonic) etc, complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
S&F as in repairs vitreous China squatting pan, 'Orissa' pattern, size 580 X 440mm white, with integral foot rests, complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
S&F as in repairs Vitreous China wash down water closet pan (pedestal pattern), including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S&F as in repairs health faucet (ABS Body mild steel chromium plated suitable for 15mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including making connections and fixed in position , complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S&F in repairs aluminium anodised tubular towel rail 20mm dia 600mm long including necessary aluminium brackets complete all as specified and as directed.

10

-

-

... More
Taking up or down 15mm bore steel tubing and connections, complete all as specified and directed by Engineer-in-Charge.

120

-

-

... More
Taking up or down 20mm bore steel tubing and connections, complete all as specified and directed by Engineer-in-Charge.

35

-

-

... More
Refixing old 15mm bore steel tubing and connections in new or old position (Walls, ceiling, floors, etc.), complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
S&F 15mm bore steel water tubes, medium grade, galvanised, with all fitting and fixed complete to walls ( concealed) and ceilings or laid in floors, complete all as specified and directed by Engineer-in-Charge.

130

-

-

... More
S&F 20mm bore steel water tubes, medium grade, galvanised, with all fitting and fixed complete to walls (concealed) and ceilings or laid in floors , complete all as specified and directed by Engineer-in-Charge.

85

-

-

... More
S&F 15mm bore dia Bib taps, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed , complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
S&F as in repairs 15mm bore dia Bib taps, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed , complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
S&F 20mm bore dia Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
M&L for flat rough finished Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), complete all as specified and directed by Engineer-in-Charge.

30

-

-

... More
M&L for rough finished Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, complete all as specified and directed by Engineer-in-Charge.

40

-

-

... More
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips ,complete all as specified and directed by Engineer-in-Charge.

410

-

-

... More
M&L for reinforced cement concrete type B1 (1:2:4) (nominal mix) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed by Engineer-in-Charge.

4.05

-

-

... More
M&L for Providing precast cement concrete type B-1 (1:2:4) by using 20mm graded stone aggregate as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and set in CM 1:4, complete all as specified and directed by Engineer-in-Charge.

1.5

-

-

... More
Taking down cement plaster on brick wall including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed by Engineer-in-Charge.

740

-

-

... More
M&L for rendering 15mm thick CM 1:6 on fair faces of brickwork or concrete surface and finished surfaces even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.

80

-

-

... More
M&L for rendering 15mm thick CM 1:6 on stone masonry surface or surfaces other than fair face of walls and finished surfaces even and smooth without using extra cement ,complete all as specified and directed by Engineer-in-Charge.

300

-

-

... More
M&L for rendering 15mm thick CM 1:4 on stone masonry surface or surfaces other than fair face of walls and finished surfaces even and smooth without using extra cement ,complete all as specified and directed by Engineer-in-Charge.

400

-

-

... More
M&L for rendering 15mm thick CM 1:4 on brickwork or concrete surface of walls and finished surfaces even and smooth without using extra cement and by using WPC @3 % by weight of cement, complete all as specified and directed by Engineer-in-Charge.

195

-

-

... More
Supply only liquid water proofing compound ,complete all as specified and directed by Engineer-in-Charge..

55

-

-

... More
M&L for preparation of new plastered or unplastered surfaces of walls including scrapping and applying two coats of distemper oil emulsion over a coat of primer strictly as per manufacture instruction with smooth roller finish ,complete all as specified and directed by Engineer-in-Charge.

380

-

-

... More
M&L for Preparation of new plastered surfaces of wall and apply two coats of Acrylic emulsion exterior paint of required shade : (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) and upto 5th floor of bldg., complete all as specified and directed by Engineer-in-Charge.

520

-

-

... More
M&L for complete removal of existing treatment on old surface of walls and applying 2 coats of Oil Bound Distemper over 1 mm thick wall care putty on wall surfaces,complete all as specified and directed by Engineer-in-Charge.

200

-

-

... More
Preparation of old wall surfaces and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) , complete all as specified and directed by Engineer-in-Charge.

350

-

-

... More
M&L preparation of new wooden surface and apply two coats of synthetic enamel paint of any description, over 10 cm in width or girth, not otherwise described, over a coat of pink primer, complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
M&L for providing and injecting chemical emulsion for post constructional antitermite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron, complete all as specified and directed by Engineer-in-Charge.

108

-

-

... More
M&L for providing and injecting chemical emulsion for post constructional antitermite treatment At points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same, complete all as specified and directed by Engineer-in-Charge.

90

-

-

... More
M&L for providing and injecting chemical emulsion for post constructional antitermite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors, complete all as specified and directed by Engineer-in-Charge.

180

-

-

... More
M&L for Excavating over areas in soft / loose soil , n exc 1.5 m deep and getting out , complete all as specified and directed by Engineer-in-Charge.

16

-

-

... More
M&L for Excavating over areas in Hard /dense soil, exc 1.5 m deep but n.exc 3.00m deep and getting out , complete all as specified and directed by Engineer-in-Charge.

11

-

-

... More
M&L for Excavating over areas in soft/ disintegrated rock , exc 1.5 m deep but n.exc 3.00m deep and getting out , complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Excavating in post holes (or similar holes) each n exc 0.5cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed by Engineer-in-Charge.

22

-

-

... More
M&L for Loose filling with broken bricks aggregates of gauge 80 to 150 mm in soakage pits, soakage wells, complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
M&L for cement concrete as in foundations, filling and mass concrete type B2 1:2:4 (using 40mm graded stone aggregate), complete all as specified and directed by Engineer-in-charge.

2.23

-

-

... More
S&F Joist, channel, angle, or tee sections, vertical posts fixed independently, without connecting plates, etc. confirming to Fe 410- W (Gde- E-250) quality -A, complete all as specified and directed by Engineer-in-Charge.

750

-

-

... More
S&F rolled sections as in main & cross beams , columns, hip and jack rafters , purlins where connected to common rafters and running rails & any other places with angles cleats or other connected plates, wind ties etc confirming to Fe 410 -W (Gde-E-250) quality A, complete all as specified and directed by Engineer-in-Charge.

900

-

-

... More
S&F plates (plain or chequered ) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, confirming to Fe 410 -W (Gde-E-250) quality A, complete all as specified and directed by Engineer-in-Charge.

110

-

-

... More
S&F Hand rails, half round or other steel section , for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts, posts &struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets ( for securing wire mesh) ,complete all as specified and directed by Engineer-in-Charge.

65

-

-

... More
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings ,complete all as specified and directed by Engineer-in-Charge.

50

-

-

... More
Supply and fix Pre-painted Galvalume Aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engineer-in-Charge.

120

-

-

... More
Supply and fix Pre-painted Galvalume Aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall at 5th floor, fixed with self tapping screws, complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
M&L for Preparation of new steel surfaces & apply two coats of synthetic enamel paint over a coat of red oxide, complete all as specified and directed by Engineer-in-Charge.

100

-

-

... More
Material and labour for cement 1:2:4 type B-1 (20mm graded stone aggregate) as in roof kerbs and levelling course on RCC roof surfaces ,complete all as specified and directed by Engineer-in-Charge.

1.3

-

-

... More
M&L for cutting chases not exc 10 cm, pinning in, making good to facings where required and plastering in CM 1:3 after fixing of sheets in brickwork or in concrete surfaces, complete all as specified and directed by Engineer-in-Charge.

42

-

-

... More
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft /loose soil, complete all as specified and directed by Engineer-in-Charge.

100

-

-

... More
M&L for 100mm thick cement concrete type D2 1:4:8 as in sub bases, sub floors etc , complete all as specified and directed by Engineer-in-Charge.

270

-

-

... More
M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 25mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed by Engineer-in-Charge.

150

-

-

... More
M&L for 75mm thick cement concrete type B-2 1:2:4 as in floors, pavings etc and finishing cement concrete surface even and smooth , and making impressions of expended metal, whilst the concrete is green, complete all as specified and directed by Engineer-in-Charge.

170

-

-

... More
M&L for cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundational filling, mass concrete of area drain ,complete all as specified and directed by Engineer-in-Charge.

11.1

-

-

... More
M&L for Precast cement concrete with PCC (1:3:6) as using 20mm graded stone aggregate in block masonry with solid blocks exc 10cm in width and setting in CM (1:6) ,complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
M&L for cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in coping including necessary form work and finishes the surfaces even without using extra cement, complete all as specified and directed by Engineer-in-Charge.

2.5

-

-

... More
M&L for rendering 10mm thick cement plaster over PCC block Masonry surface in cement mortar (1:4) finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.

165

-

-

... More
Extra for fair finished drain or channel 30cm inner girth in cement concrete using extra cement including form moulds mitred/stopped ends etc, complete all as specified and directed by Engineer-in-Charge.

120

-

-

... More
S&F Reinforced concrete pipes of 450mm bore, class NP3, laid and jointed complete with collars, complete all as specified and directed by Engineer-in-Charge.

12

-

-

... More
M&L for Concrete bed to 450mm drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested, in cement concrete 1:3:6 type C-2, complete all as specified and directed by Engineer-in-Charge.

12

-

-

... More
M&L for Hardcore broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
M&L for 100mm thick cement concrete type B1 (1:2:4) by using 20mm graded stone aggregate as in ,hard standing, paving and finishing concrete surface even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed by Engineer-in-Charge.

950

-

-

... More
Returning, filling in soft/loose soil, hard/dense soil including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and directed by Engineer-in-Charge.

40.3

-

-

... More
Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed ,complete all as specified and directed by Engineer-in-Charge..

88.2

-

-

... More
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil, complete all as specified and directed by Engineer-in-Charge.

88

-

-

... More
S&F for 150mm bore RCC pipe class NP-2 laid and jointed complete with collars as specified including testing ,complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in bed to drain pipes including forming cradle after they are laid and tested for 150mm bore RCC pipe, complete all as specified and directed by Engineer-in-Charge.

18

-

-

... More
S&F for 200mm bore of RCC pipe class NP-2 laid and jointed complete with collars as specified including testing, complete all as specified and directed by Engineer-in-Charge.

60

-

-

... More
M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in bed to drain pipes including forming cradle after they are laid and tested for 200mm bore RCC pipe, complete all as specified and directed by Engineer-in-Charge.

58

-

-

... More
M&L for 15mm thick cement plaster in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement), complete all as specified and directed by Engineer-in-Charge.

35

-

-

... More
M&L for PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in foundations, filling ad mass concrete ,complete all as specified and directed by Engineer-in-Charge.

2.25

-

-

... More
M&L for cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in benching, coping, cills steps, parapets, railings up to 60cm in height, water troughs and the like rounded or chamfered on edges including necessary form work , complete all as specified and directed by Engineer-in-Charge.

0.18

-

-

... More
M&L, Extra for forming fair finished drain or channel 20cm inner girth in cement concrete, using ex-tar cement, including forms, moulds, mi-tred/stopped ends etc. complete all as specified and directed by Engineer-in-Charge.

6

-

-

... More
Taking down carefully point wiring and removing from site such as (Light, fan socket or power) Complete including fitting and fixtures, fan regulators switch boards,switches,ceiling rose's lamp holder from existing batten PVC conduit/steel conduit wiring complete excluding light fittings and fans all as specified and making good to the disturbed surfaces to match with existing ,complete all as specified and directed by Engineer-in-Charge.

54

-

-

... More
M & L for point wiring complete for light on independent /combine board with cable 1.5 sqmm (Nominal area) FRLS PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC casing & capping, hooks , elbows, junction covers and junction boxes and sinking's for sunken GI terminal boxes Min 50mm deep ,suitable length and 1. 6 mm thickness for mounting, switches, sockets, fan regulator with 3 mm thick plastic laminated sheet cover fixed with cadmium plated screwed and cup washers, duly grouting and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth continuity conductor along with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switch and connected to common earth dolly, complete all as specified and directed by Engineer-in-Charge.

39

-

-

... More
All as per Srl item No -119.00 here in before but for one socket outlet 5/6 amp on independent board, complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
All as per Srl item No -119.00 here in before but for one three pin socket outlet 5 Amp on same board with other switches, complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
All as per Srl item No. 119.00 here in before but for one switch socket combination 6 pin 6/ 16 Amps on independent board with copper conductor 2.5 Sqmm ,complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
S&F Switch piano, flush type single pole, one way 5 Amp ,complete all as specified and directed by Engineer-in-Charge.

49

-

-

... More
S&F Switch piano, flush type single pole, one way 16 Amp ,complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
S&F Socket outlet 2 in 1, 5 pin, 5A ,complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
S&F Socket outlet 2 in 1, 6 pin, 6/16A flush type ,complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
S & F stepped type, single socket fan regulator for ceiling fan 1200/1400mm sweep ,complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
S & F ceiling rose surface bakelite three terminals ,complete all as specified and directed by Engineer-in-Charge.

24

-

-

... More
Taking down carefully existing old serviceable LED Tube light/ bulkhead/ security light/ /ceiling fan of any size and refixing the same to respective location after carrying out cleaning all the components of fittings, including replacement of nuts, bolts and connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector, complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
S & F in replacement LED Tube light fitting with polycarbonate housing and integrated electronic driver, 20 watt having input voltage AC90-300V, 50 Hz , 6500K, surge protection min 4 KVA and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector, complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
Supply and fixing LED building security light fitting 35 Watt 230 V, surge protection 10 KVA, AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.& Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 1 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 ,complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
S & F in replacement LED Water tight bulk head fitting 10 W,comprision of connector galvanised cast iron back plate, weather proof enamelled gallery ,glass well, and including 10 watt LED ,complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
S & F in replacement angle holder insulated body with back plate for conduit fittings ,complete all as specified and directed by Engineer-in-Charge.

15

-

-

... More
S&F LED lamp 9W for angle holder ,complete all as specified and directed by Engineer-in-Charge.

15

-

-

... More
S & F in replacement for Sub Main wiring with two single core 6 Sqmm PVC insulated FRLSH multistranded flexible copper conductor cable 660/1100 volts grade drawn in through flexible non metallic PVC casing capping conduit with and including PVC insulated 6 Sqmm multi strand copper conductor as continuous earth wire in green colour connected to common earth dolly ,complete all as specified and directed by Engineer-in-Charge. (Note : PVC cable and PVC casing capping shall be ISI marked) ( Make of cable - Havells/Anchor/Finolex) Note :- Two length of 6 Sqmm cable and one length of 6 Sqmm earth cable along with PVC casing capping will be measured as one running length

60

-

-

... More
S & F in replacement sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 8 ways, 240 Volts, ISI marked 200 amps bus bar stove enamelled dust and vermin proof, IP 42 suitable for incorporation MCBs and isolators etc including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessity ,complete all as specified and directed by Engineer-in-Charge.

12

-

-

... More
S & F in replacement MCB ‘B’ series type suitable for 240 volts, AC supply 6 to 32 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA ,complete all as specified and directed by Engineer-in-Charge.

12

-

-

... More
S & F in replacement MCB ‘B’ series type suitable for 240 volts,10 KA, AC supply 6 to 32 Amps , single pole (SP) with over load and short circuit protection and rupturing capacity not less than 10KA ,complete all as specified and directed by Engineer-in-Charge.

72

-

-

... More
Dismantling and Taking down L.T. under ground armoured PVC/XLPE insulated and PVC/XLPE sheeted heavy duty 1100 Volts grade under ground cable of any size, complete all as specified and directed by Engineer-in-Charge.

80

-

-

... More
Taking out old unreinforced precast concrete cable cover factory made class LV type1 flat size 250x150x40 mm during excavation of trenches , complete all as specified and directed by Engineer-in-Charge.

350

-

-

... More
Excavation in trenches not exceeding 1.5 m wide and not exe 1.5 M in depth and getting out in hard/dense soil ,complete all as specified and directed by Engineer-in-Charge.

19

-

-

... More
Supply and spreading in trenches clear dry sand for cable protection and punning down gently 10 cm below the cable and 15 cm above the cable, complete all as specified and directed by Engineer-in-Charge. Note :- Punning thickness only measured.

5.6

-

-

... More
Supply and laying unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 ISI marked flat size 250x150x40 mm laid in trenches ,complete all as specified and directed by Engineer-in-Charge.

350

-

-

... More
M&L for cutting existing road/hard standing not exc 50x60 cm in wide & depth getting out excavated material for laying GI tube , for passing through LT cable, returning filling & well ramming watering finish surface 10 cm from top using PCC 1:1.5:3; including removal of surplus soil, complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
Supply and lay jointing and testing and commissioning in replacement of 16 Sqmm 2 core XLPE insulated, screened , PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/laid under roads/paths/drain/culverts or passing through pipes, complete all as specified and directed by Engineer-in-Charge.

80

-

-

... More
Material and Labour for Earthing complete with copper plate60cm×60cm ×3.15mm thick electrode, burried directly in ground ( earth pit not less than 2.25 mtrs below ground level) with top edge of the plate not less than 1.5 mtr normal ground level, connected to 20×3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel as shown in electrical plate No 3 of MES SSR Part-I 2009 connected to earthing test point by means of copper Strip of size 20x3 mm including earthwork, PCC chamber, CI cover, GI pipe protection for strip and watering pipe, funnel, mesh etc all as required at site and all as directed. Note: (i). 7.5 RM Copper strip in deemed to be included in quoted rates beyond 7.5 RM strip shall be measured and paid separately. (ii). Earth resistance of earth pit should be less than 1.0 Ohms. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (iii) Rate quoted by the tenderer is deemed to include for salt & Charcoal upto & above 450 mm top of earthing plate, testing ,complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Supply and lay GI pipe 50 mm light grade for cable protection in walls trenches or any situation including clamp nut bolt etc,complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
M&L for steel water tubing medium grade of size 25 mm bore with all fittings laid in trenches or fixed to wall or floor, complete all as specified and directed by Engineer-in-Charge.

30

-

-

... More
M& L Cutting existing steel tubing for alterations or additions 40m or 50 mm size , Add if necessarily done in position without taking down ,complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S & F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe 25 mm and fixed ,complete all as specified and directed by Engineer-in-Charge.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.