Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date2 Jan 2025
Closing Date1 Feb 2025
Tender Amount₹ 72,00,000
Costs
EMD
₹ 1,33,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_691486_1Tender No
88624/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
TENDER INVITING FOR REPAIRS TO RCC ROOFS AT VARIOUS BLDGS IN AOR OF AGE B/R-I UNDER GE (N) AHMEDNAGAR
BOQ Items
... More
M & L for 10 mm thick cement plaster in CM (1:3) on roof slab / Chajja top with a mixture of water proofing liquid @ 3% by weight of cement on dried concrete surface finished fair and even without using extra cement. Note :- water proofing liquid shall be measured and paid seperately.
3000
-
-
... More
M&L for cleaning the newly plastered surfaces of concrete (roof etc) with wire brushes and applying water proofing treatment as under :- (a) Checking the roof slab by flooding test with water till total elimination of leakage seepage / dampness all as specified in SSR Part-I. (b) Brushing surface with neat cement slurry at the rate of 3.00kg of cement per Sqm. (c) Applying one coat of oil bound bituminous primer @ 0.25 kg/Sq. M (d) Providing and laying 3mm thick APP modified water proofing membrane weighing not less than 3.5 Kg/Sqm reinforced with non woven polyester mat weighing not less than 160 gm/Sqm all as specified procured from any one of the approved manufactures (e) Apply two coat of solar reflective bituminous aluminium paint @ 0.15 kg/Sqm per coat over membrane over non assesble roof surfaces complete all as per manufactures instructions and as directed
1000
-
-
... More
M&L for preparing of concrte /plastered roof /Chajjas etc with and including comprising of the following steps:- (a) Checking the roof slab by flooding test with water till total elimination of leakage / seepage / dampness all as specified in SSR Part-I (b) Cleaning & drying thoroughly existing surface of roofs,chajjas etc for all forign matters such as fungus,moss dust etc by wire brushing and dusting. (c) Removing loose concrete surfaces cracks etc and then apllying/filled with Dr fixit crack x or polymer modified mortar in case of wider cracks ( Bitumen based water proofing treatment must be removed by mechanical sacrification) or equvalent in SIKA / STP / BERGER. (d) Applying one coat of Dr fixit roof seal top coat (diluted with water 2:1) at the rate of 100-110 Sqft/Ltr and then allow it to dry for 2-3 hrs or equivelent in SIKA/STP. (e) Applying two coats of Dr fixit roof seal top coat ( diluted with water 2:1) embded a glass fiber mest (2x2mm-40gms) between the first and second coat as reinforcement complete all as specified and directed. Make:- Dr Fixit roof seal or eqivelent in SIKA/STP/Bergar as approved by GE. Note:- Work shall be carried out through authorised applicator of the approved product only & 05 years waranty will be submitted by manufacturer.
400
-
-
... More
M&L preparation of surfaces thoroughly by cleaning, washing and removing dust, dirt, oil and loose particles and applying special grade of primer PR-71 of chokesy chemicals 1.10 Kg/Sqm or equivelent of Dr fixit,Pidilite,Asian,Sika. Note:- Application of liquid water proof material only will be carried out thorugh manufactures.
2000
-
-
... More
M&L preparation for applying two coats (with colour pigment) of high performance PU based cold applied elastomeric coating having solid content 80% shore, a hardness Min 60,tensile strength 1.50 to 2.0 N/mm2 TECH O THANE PU white @ 0.95 Kg per Sqm (0.45 Kg /Sqm /per coat) with dry film thickness of 1 to 1.20 mm on previously primed surface of chokesy chemical or equivelent of Dr.Fixit, pidilite, Asian, Sika. Note:- Application of liquid water proof material only will be carried out thorugh authorised manufactures. 05 years waranty will be submitted by manufacturer.
3000
-
-
... More
M&L preparation of surfaces thoroughly by cleaning, washing and removing dust, dirt, oil and loose particles and applying liquid water proofing and seepage proof product of Dr. Fixit, Pidicrete,Asian ,Sika ,chokesy ltd in two coats as per manufacture instruction mix with cement on wall surafce . Note:- Application of liquid water proof material only will be carried out thorugh manufactures.
1000
-
-
... More
Taking down cement plaster on brick or concrete surfaces on wall/ceilling/stone/block etc including racking out joint, hacking for key,scrubbing down with water etc all as specified and as directed.
100
-
-
... More
Demolition of brick work or stone/ boulder masonry/PCC block, built in cement mortar or cement lime mortar including all quoins, pillars etc.
5
-
-
... More
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6
5
-
-
... More
M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 , finished even and smooth without using extra cement including water proofing compound @ 3% by weight of cement all as specified and as directed.
120
-
-
... More
M&L for rendering 10 mm thick in CM 1:6 over brick surfaces, finished even and smooth without using extra cement all as specified and as directed.
50
-
-
... More
M & L applying two coats of OBD over a coat of primer on newly plastered wall surfaces iover 2 coat of wall care putty preparation of surfaces all as specified and as directed.
50
-
-
... More
Supply only Liquid water proofing compound
70
-
-
... More
M&L for Finishing walls with Acrylic Smooth exterior paint of required shade (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
800
-
-
... More
M&L for preparing surfaces of walls applying two or more coat of smartcare Damp proof advance water proof paint Asian or equivalent including scafolding at any height complete all as specified and directed by Engineer-in-charge.
800
-
-
... More
Dismantling of wrought iron or mild steel work of any description not otherwise provided for all as specified and directed.
4.3
-
-
... More
Dismantling boarding, any description, fixed in wall or ceiling, any position with nails
400
-
-
... More
M&L for Fibre glass reinforced translucent plain / corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed by Enggineer-in-charge.
400
-
-
... More
S & F Rolled Mild Steel Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to Fe 410 - W (Gde E-250)quality-A, complete all as specified and directed by Enggineer-in-charge.
860
-
-
... More
M&L for preparing new steel surfaces of any description over 10cm width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed.
20
-
-
... More
Taking up or down steel tubing 15mm dia and connections, including cleaning for re- fixing or removal to store complete all as specified and directed by Engineer-in-charge.
50
-
-
... More
Taking up or down steel tubing 20mm dia and connections, including cleaning for re- fixing or removal to store complete all as specified and directed by Engineer-in-charge.
50
-
-
... More
Taking up or down steel tubing 25mm dia and connections, including cleaning for re- fixing or removal to store complete all as specified and directed by Engineer-in-charge.
18
-
-
... More
S&F for 15mm dia tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floor complete all as specified and directed by Engineer-in-charge.
50
-
-
... More
S&F for 20mm dia tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floor complete all as specified and directed by Engineer-in-charge.
50
-
-
... More
S&F for 25 mm dia tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floor complete all as specified and directed by Engineer-in-charge.
18
-
-
... More
Disconnecting existing PVC water tanks of capacity exc 500 litres & n.exc 1000 ltrs tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.
15
-
-
... More
Disconnecting existing PVC water tanks of capacity exc 250 litres & n.exc 500 ltrs tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.
15
-
-
... More
Dismantling existing PVC water tanks of capacity exc 500 litres & n.exc 1000 litres all as directed and removed from site. NOTE:-Dismantled water tank shall become the contractors property as per Sch of credit.
10
-
-
... More
Dismantling existing PVC water tanks of capacity exc 250 litres & n.exc 500 litres all as directed and removed from site. NOTE:-Dismantled water tank shall become the contractors property as per Sch of credit.
5
-
-
... More
S&F 500 litres rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed .
5
-
-
... More
All as per above item but 1000 ltrs
10
-
-
... More
S&F nipple 20mm dia suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms)
15
-
-
... More
S&F in repairs for 20mm Dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed
15
-
-
... More
S and F Ball brass valve 20 mm dia high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule
15
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%