Military Engineer Services Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date6 Nov 2024
Closing Soon27 Nov 2024
Tender Amount₹ 50,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling framed steel trusses of span n.exc 10m complete all as specified and as directed.

5

-

-

... More
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.

3

-

-

... More
Dismantling timber scantlings 40 sqcm and over in section, in any position, such as in rafter, purlin etc as in unframed work, complete all as specified and directed.

1

-

-

... More
Dismantling timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 Sqcm in section, in any position all as specified and as directed.

300

-

-

... More
Dismantling battens for tiles, shingles etc, of any size including tilting fillets spaced not exc 30 cm complete all as specified and as directed.

145

-

-

... More
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.

160

-

-

... More
Dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof coverings including ridges complete all as specified and as directed.

1185

-

-

... More
Dismantling of mangalore pattern or similar tiles in roofing complete all as specified and as directed.

145

-

-

... More
Taking down cement or cement lime plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.

310

-

-

... More
Taking up or down 15 mm bore GI water tubing and connections including all fittings complete all as specified and as directed.

70

-

-

... More
Taking up or down 20 mm bore GI water tubing and connections, including all fittings complete all as specified and directed.

130

-

-

... More
Taking up or down 25 mm bore GI water tubing and connections including all fittings complete all as specified and directed.

60

-

-

... More
Taking down eaves gutters and rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc complete all as specified and as directed.

152

-

-

... More
M&L for providing cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate in roof kerbs in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses lacing courses, parapets and railings coping, kneelers, apex stones, bed plates, water throughs and the like including weathering, slightly rounded or chemfered angles and throating complete all as specified and as directed .

3

-

-

... More
M&L for brick work with fly ash bricks, class designation 75 (Kgf/cm2) straight or curved on plan exceeding 6m mean radius and built in cement mortar 1:6 complete all as specified and as directed.

6

-

-

... More
All as per serial item No. 18 but except bricks. Note : Serviceable bricks obtained from the demolition shall be reused.

0.5

-

-

... More
S&F laminated Gypsum tile board 8mm thick with textured white colour PVC film on the face side and metalized polyster (MPL) film on rear side in ceiling as per manufacturers instructions of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, including dismantling existing false ceiling work of any description all as specified and as directed..

520

-

-

... More
S&F prepainted galvalume aluminium zinc coated galvanised iron based corrugated steel sheets, 0.5 mm thick of any colour having tensile strength 550 MPA as in roof covering or ridges, hips and straight flashing or in fixed with self taping screws (length & girth as fixed) complete all as specified and as directed.

950

-

-

... More
S&F pre-painted galvalume aluminium zinc coated galvanised Iron based Plain steel sheets, 0.5mm thick, with side lap and end lap of any colour having tensile strength 550 MPA as in ridges, hips, valley gutters, drip and straight flashing or in roof covering/cladding fixed with self taping screws (length & girth as fixed) complete all as specified and as directed.

90

-

-

... More
S&F 6mm thick, Asbestos cement corrugated or semi corrugated sheets in roofs, walls etc, fixed with L or J type or cranked hook bolts complete all as specified and as directed.

100

-

-

... More
Fixing only old 6mm thick Asbestos cement corrugated or semi corrugated sheets in roofs, walls etc, fixed with L or J type or cranked hook bolts complete all as specified and as directed. Note :- Serviceable sheets obtained from dismantling shall be reused.

15

-

-

... More
S&F 6mm thick Asbestos cement two piece serrated ridge for corrugated or semi corrugated sheets, fixed with L or J type or cranked hook bolts complete all as specified and as directed

30

-

-

... More
S&F Polycarbonate twin wall sheet total thickness 6mm with joint of two sheet fixed with aluminium flat size 15x1mm as per requirement and necessary screw and washer in roof, wall etc complete all as specified & directed. Note :- Colour & Pattern approved by Engineer-in-Charge.

160

-

-

... More
Cutting holes into or through brick wall built in cement lime mortar and walls of cement concrete of superficial area exc 150 sqcm but n exc 400 sqcm and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified & as directed by Engr-in-Charge.

350

-

-

... More
S&F rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe-410W grade E-250 quality-B with and including one shop coat of zinc chrome primer including preparation of new surfaces complete all as specified and as directed.

750

-

-

... More
S&F rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates. Fe 410 -W (Gde- E- 250) quality- A all as specified and as directed.

2000

-

-

... More
S&F mild steel work in tubular trusses including special shaped washer etccomplete using ERW or induction butt welded tubes conforming to IS - 1161-1979 grade complete all as specified and as directed.

400

-

-

... More
M&L for welding in repairs n exc 2.5cm in length and thickness of metal to be welded not exc 6 mm all as specified and as directed.

50

-

-

... More
M&L for second class hardwood clean sawn batten, sectional area exc 5sqcm & n.exc 15 Sqcm at spacing 15cm centres complete all as specified and as directed.

200

-

-

... More
Fixing only old clean sawn batten at spacing 15cm centre of second class, hardwood exc 5Sqcm & n.exc 15Sqcm sectional area complete all as specified and as directed. Note : Old serviceable battens obtained from dismantling shall be reused.

50

-

-

... More
M&L for roof tiles mangalore pattern, interlocking at side joint laid dry complete all as specified and as directed.

120

-

-

... More
Fixing only old roof tiles mangalore pattern, interlocking at side joint laid dry complete all as specified and as directed. Note : Old roof tiles mangalore pattern obtained from dismantling shall be reused.

25

-

-

... More
M&L ridge or hip tiles to suit Mangalore pattern or roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and as directed.

40

-

-

... More
Fixing only ridge or hip tiles to suit Mangalore pattern or roofing tiles, bedded and jointed in lime mortar 1:3 or cement mortar 1:6 complete all as specified and as directed. Note : Old ridge tiles obtained from dismantling shall be reused.

20

-

-

... More
M&L for special treatment to sunken slab floor including WC trap etc including cleaning and preparing the surface area for carrying out membrane water proofing treatment, then injection grouting the weak areas on the concrete surface with cementitious grout and applying 10mm thick cement plaster in CM 1:4. Then providing and laying Mineral Top APP (Atactic Polypropylene Polymer) modified prefabricated 5 layer 4mm thick water proofing membrane, black finished reinforce with non woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 Litre per Sqm by the same membrane manufacturer of density at 25ºC, 0.87-0.89 Kg per litre and viscosity 70-160 CPS over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc and preparing the surface complete. and providing PCC 1:5:10 type E2 using 40mm graded mechanically crushed stone aggregates in sunken slab and 75mm thick PCC 1:4:8 type D2 using 40mm graded mechanically crushed stone aggregates as base, 40mm bore GI pipe, light grade of length not less that 50 cm as spout, non-skid glazed tiles as per existing pattern/size/tint with and incl WC vitreous china squatting pan 580x440mm with integral footrests/pedestal pan incl seat cover, white, area of WC n exc 1.50 Sqm each etc after dismantling the existing sunken floor etc complete all as specified and as directed. Note : Work shall be carried out strictly by the authenticated applicator of the manufacturer and as per manufacturers specifications as approved by GE.

6

-

-

... More
All as per serial item No 38 above but floor area of WC/bath-room/toilet exc 1.5 Sqm but not exceeding 3.0 Sqm.

4

-

-

... More
S&F in repair vitreous China, Squatting pan, Orissa pattern, size 580 x 440mm, white with integral foot rests (excluding flushing cistern and flush pipe ) with Vitreous China ‘P’ or ‘S’ trap, front or back inlet including connection to trap and to flushing pipe, anti syphonage pipe, including PCC (1:2:4) type B-1 for fixing of WC and making good the floor to match the existing complete all as specified and as directed.

1

-

-

... More
S&F in repair vitreous China wash down water closet pan (pedestal pattern), white, including plastic white seat cover closed pattern with flat bottom and mild steel chromium plated hinge device including connections to drain (or outgoing pipe ) and to flushing pipe anti syphonage pipe etc complete all as specified and as directed

1

-

-

... More
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) and rubbish off the premises etc complete all as specified and as directed.

90

-

-

... More
M&L for coloured non-skid ceramic tiles, 7 to 8 mm thick (Square or Rectangular), area of each tiles exc 0.06 Sqm but n exc 0.11 Sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over & including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.

20

-

-

... More
M&L for non-skid coloured ceramic tiles, 7 to 8 mm thick (Square /Rectangular) area of each tile exc 0.11 sqm but not exc 0.18 sqm as in floors etc set and jointed in neat cement slurry and pointed in white cement to match with tiles, laid over and including screed bed or bedding layer of 15 mm thick in cement mortar 1:6 complete all as specified and as directed.

20

-

-

... More
M&L for glazed coloured ceramic tiles (shade as approved by GE) of size 350mm x 250mm x 7mm/450mm x 300mm x 7 mm thick, as in dado, skirting, risers to step etc laid over and including 10 mm thick backing coat in cement mortar 1:4, jointed in neat cement slurry and pointed in coloured cement to match with colour of tiles complete all as specified and as directed.

50

-

-

... More
Taking down existing roof treatment of any type and any thickness including mud in roofs, plastering, leeping plaster of any thickness cutting & uprooting trees /roots / vegetation growth & removing the debris from the site premises distance upto 1 km from the site and material and labour for providing and laying in situ water proofing treatment with APP (Atactic Polypropylene) polymer modified prefabricated membrane over roof with following procedure complete all as specified & as directed:- (a) Cleaning existing surface properly. (b) Providing and laying 10mm thick screed bed with cement mortar 1:3 in roof surface with and including WPC (liquid) as per manufacturer's instructions. (c) Applying a coat of bitumen primer @ 0.40 litre/sqm on prepared surface. (d) Laying water proofing roof membrane APP polymer modified prefabricated membrane using Butane torch by torch application with 100 mm side laps and 150 mm end lap. All overlap shall be firmly bonded with bitumen primer and levelled by heating the overlaps with Butane torch. Physical properties of APP membrane shall be as under :- (i) Membrane thickness - 3 mm (minimum) (ii) Membrane weight - 3.60 Kg/Sqm (minimum) (iii) Five layer reinforced with Non woven polyester weight not less than 150 Gm/Sqm. (e) Applying two coats of bituminous aluminium paint over APP membrane @ 0.11kg/sqm for each coat. Note : The cost of liquid WPC shall deemed to be included in the rate quoted.

1950

-

-

... More
M&L for Cutting out cracks to V-section in existing roofs or terracing, cleaing out, and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 ( by weight) complete all as specified and as directed.

200

-

-

... More
M&L for cleaning existing surfaces properly with steel wire brushes by removal of all loose particle to ensure clean, smooth and dry surface and laying 25mm thick plain cement concrete type B-0,(1:2:4) using 12.5mm graded stone aggregate, finished even and smooth without using extra cement complete all a specified and as directed.

800

-

-

... More
M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work finished the surfaces even and fair complete as specified and as directed.

180

-

-

... More
M&L for rendering 15 mm thick in cement mortar 1:6 on other than fair faces of brick wall or concrete surface or stone masonry surfaces including finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.

100

-

-

... More
M&L for rendering 5 mm thick on fair faces of brick work or concrete surfaces of ceiling in cement mortar 1:3, finished even & smooth without using extra cement complete all as specified and as directed

30

-

-

... More
M&L for extra over rendering or plastering for work in isolated width or in widths not forming part of general plastering such as in bands, sunk panels, cornices, skirtings, drip moulds and simmilar work n exc 15cm in width and girth, including cutting to edges, all mitres and stopped ends, etc. complete all as specified and as directed

50

-

-

... More
M&L for Dubbing out average 10mm thick cement plaster in CM 1:4 on irregular face of walls or concrete chajjas (when specifically ordered in writing) (at any height of building) including necessary scafolding complete all as specified and directed

30

-

-

... More
M&L for disconnecting existing tanks exc 250 ltrs and n.exc 500 ltrs capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and refixing in position including cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc and writing date of cleaning on tank complete all as specified and as directed.

80

-

-

... More
M&L for disconnecting existing tanks exc 500 ltrs and n.exc 1000 ltrs capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and refixing in position including cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc and writing date of cleaning on tank complete all as specified and as directed.

10

-

-

... More
S&F rotational moulded polyethylene triple layered water storage tanks of any colour with 500 lts capacity (cylinderical vertical with closed top) hoisted and fixed in position with and including ball valve 20 mm bore high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight not less than 210 grams) including dismantling of exisiting tank complete all as specified and as directed.

15

-

-

... More
S&F rotational moulded polyethylene triple layered water storage tanks of any colour with 1000 lts capacity (cylinderical vertical with closed top) hoisted and fixed in position with and including ball valve 20 mm bore high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight not less than 210 grams) including dismantling of exisiting tank complete all as specified and as directed.

6

-

-

... More
S&F in repairs ball valve, 20mm bore, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball (minimum weight 210gms) screwed for iron pipe and fixed all as specified and as directed.

45

-

-

... More
M&L for UPVC pipes, 15 mm bore (Pressure rating 10 kgf/cm²) laid in trenches / floors or fixed to wall in any length with all UPVC fitting such as sockets, bends, elbows, tees, reducers, unions, jointing materials etc and pressure testing, washing out complete including dismantling/ taking out old pipe complete all as specified and as directed.

15

-

-

... More
M&L for UPVC pipes, 20 mm bore (Pressure rating 10 kgf/cm²) laid in trenches / floors or fixed to wall in any length with all UPVC fitting such as sockets, bends, elbows, tees, reducers, unions, jointing materials etc and pressure testing, washing out complete including dismantling/ taking out old pipe complete all as specified and as directed.

50

-

-

... More
Supply, fixing, laying and testing 15 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors and testing complete all as specified and as directed.

40

-

-

... More
Fixing only old 15mm bore GI water tubes in short lengths with all new fittings and fixed complete to walls, ceilings or laid in floors complete all as specified and as directed. Note : Serviceable old pipes obtained from dismantling shall be reused.

15

-

-

... More
Supply, fixing, laying and testing 20 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors and testing complete all as specified and as directed.

60

-

-

... More
Fixing only old 20mm bore GI water tubes in short lengths with all new fittings and fixed complete to walls (concealed) ceilings or laid in floors complete all as specified and as directed Note : Serviceable old pipes obtained from dismantling shall be reused.

20

-

-

... More
Supply, fixing, laying and testing 25 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors and testing complete all as specified and as directed.

40

-

-

... More
Fixing only old 25mm bore GI water tubes in short lengths with all new fittings and fixed complete to walls, ceilings or laid in floors complete all as specified and as directed Note : Serviceable old pipes obtained from dismantling shall be reused.

20

-

-

... More
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and as directed.

2

-

-

... More
M&L for cement concrete 1:2:4, type B0 (using 12.5mm graded stone aggregates) as in chajjas, Fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, and the like complete all as specified and as directed.

2

-

-

... More
M&L for mild steel TMT bars 6 mm dia and over cut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia as in reinforcement bar complete all as specified and as directed.

90

-

-

... More
Use and waste of formwork to sides and soffits of chajjas/ facia/ parapet and similar work at any height for rough finished surfaces of concrete complete all as specified and as directed.

10

-

-

... More
Use and waste of formwork to sides and soffits of fins, facia, louvers and similar work at any height for rough finished surfaces of concrete complete all as specified and as directed.

20

-

-

... More
M&L for preparation of new plastered or unplastered surfaces of walls and applying three coats of white wash complete all as specified and as directed.

40

-

-

... More
M&L for preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.

30

-

-

... More
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint over and including a coat of primer complete all as specified and as directed

180

-

-

... More
M&L for preparation of new plastered wall surfaces, and applying minimum 1mm thick wall care putty over prepared wall surface including sanding of the putty surface after drying to achieve even and smooth finish and applying two coat of oil bound distemper over and including a coat of primer complete all as specified and as directed.

60

-

-

... More
M&L for preparing surfaces of tiles or slate battens, any size and spacing and treated all over (measured overall on one side only, spaces not deducted) and treated with Creosote complete all as specified and as directed.

190

-

-

... More
M&L for applying two coats of synthetic enamel paint to primed steel surfaces of any description (of truss/purlins/rafters,etc), over 10cm in width or girth, not otherwise described complete all as specified and as directed.

90

-

-

... More
S&F PVC (SWR) pipes 110mm bore, single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed.

120

-

-

... More
S&F PVC (SWR) pipes 75mm bore, single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed.

32

-

-

... More
S&F PVC (SWR) bends any radius, 110 mm bore complete all as specified and as directed.

16

-

-

... More
Supply and fix in repairs stack clamps made out of 50mm X 5mm flat iron and 16 mm round iron stay including bolts and nuts and securing ends stays to wall or roof all as specifed and as directed.

24

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.