Western Railway Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Western Railway - WR Tender
Telecommunication Services
Ireps
Opening Date10 Jan 2025
Closing Date31 Jan 2025
Tender Amount₹ 9,06,156.32
Costs
EMD
₹ 18,100Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
SandT-RTM-25-Tele-01-RATLAM DIVISION-S AND T/WESTERN RLYTender No
SandT-RTM-25-Tele-01Tender Authority
Western Railway ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply of 8 port Manageable POE switch with 2 SFPs and its standard installation as per specification
4
13257
53030.48
... More
Supply of RJ 45 Connector DAX, D-link, Digisol, AE, Molex, Amphenol make as approved by Engineer in charge
150
5
864
... More
Supply of 19'' 24 U rack to accommodate equipment with all accessories as per technical specifications
1
21213
21213.5
... More
Supply of HDPE Ducts 40/33 mm dia as per RDSO/SPN/TC/45/2013 Rev 2.0 with latest amendments as available. Each km of HDPE duct should have 2 no End Plugs, 2 no Cable sealing plugs, and 2no plastic couplers slip fit/push fit type.
1500
55
83310
... More
Supply of SWITCH BOARD CABLE (10 PAIR) CONFIRMING TO TEC PECIFICATION G/WIR- 06/03 MAR 02 OR LATEST MAKE:- NETWORK CABLE OR SIMILAR. 9
-
-
8
... More
Supply of 6 core armoured Mono mode OFC cable as per specification
1500
24
36870
... More
Supply of CAT-6 cable of Dlink, Digisol, Securenet,paramount, polycab make (with identification mark/ferrules etc.) as per Technical Specification.
610
24
14762
... More
Supply of 9-U Dust proof Cabinet with cooling arrangement as per Technical specification
2
6377
12755.96
... More
Supply of White PVC Pipe of dia 1 Inch of as per Standard IS:9537 (Part 3) with Pipe length of 3 mtrs each (Bend and Eblow as per site requirement will be supplied along with pipe)
350
22
7941.5
... More
Supply of Half Round RCC pipes & collars of 150 mm internal dia (1 meter long) along with collars as per IS No. 458/2003 of NP type
20
204
4092.4
... More
Supply of 2 Mega Pixel bullet camera with following specification:Image sensor: 1/2.8" progressive scan CMOS illumination : 0.027lux@F1.2, AGC on, Max resolution:1920x1080 Day 14 &Night:ICR (Auto Schedule/ Alarm Trigger) Digital Noise reduction :3D DNR Video Compression/H.264/MPEG4/MJPEG systemcompatibility: ONVIF, PSIA, CGI power supply : 12 VSC + 10%POE (802.3af) Protocols : TCP/IP, ICMP, HTTP, HTTPS, FTP, DHCP,DNS, DDNS, RTP, NTP, QOSIPV6, IPv6
2
6967
13934.8
... More
Supply of Thermo shrink Universal Jointing kit for Quad Cable (for straight joints) as per RDSO spec IRS/TC-77/2012 revision 3 With latest Amd.
2
2655
5310.82
... More
Supply of Spike buster extension board, minimum 4 nos., 6 Amp 3 pin socket, 1.5 meter cable. Make- Anchor/Havells/Syska
1
662
662.24
... More
Supply of PVC flexible pipe 1 inch dia in roll grey colour suitable for electrical use confirming to IS:6946:1973 make Dutro flex of utron, Finolex,Precision, Legrand or similar
200
10
2020
... More
Supply of 2 x 24 fiber optic fiber splice straight joint enclosure (SJC) complete with all accessories. AsperRDSO/SPN/TC/ 68/2014, Rev.3 or latest amendment
4
3920
15682.72
... More
Supply of 8 Channel NVR with Recording Resolution up to 8 MP,2 SATA interfaces for HDD connection (up to 10 TB capacity per HDD), Network Interface :1RJ-45 10/100/1000 Mbps self adaptive Ethernet interface.As per Technical Specification.
1
10795
10795.42
... More
Supply & Installation of 55" LED SMART TV suitable for 24X7 working and 03 Years on- site Warranty as per Technical Specification.
1
77504
77504
... More
Installation, Testing & Commissioning of 24 Port LIU with suitable Connector as per the instructions of Engineer in Charge.
2
277
555.86
... More
Supply and installation of 2MP Full HD night vision bullet camera (including necessary 3 enclosures, clamps, housing, fixing arrangements to fix cameras on ceiling, PF shelters, poles, gates and with 3 year OEM warranty ) (Make: should be complied MAKE IN INDIA policy) as per Technical Specification.
8
9839
78713.12
... More
Supply & installation of 32 channel NVR number of video input channels-32,No. of 4 video output channels-32,recording resolution-4K(3840X2160), supporting compression techniques- H.264, H.265, MPEG-4, MPEG,H.265,H.264+,minimum cameras views on single display-16. (Make: should be complied MAKE IN INDIA policy) as per Technical Specification.
1
26559
26559.32
... More
Blowing of OFC through HDPE duct, where it is not feasible to blowOFC due to curves, road/track crossings, bridges or for any otherreason, OFC shall be drawn or laid manually as per 5 standardprocedure. In case OFC is to be laid adopting 'Direct in trench'method then approval of competent authority will be taken beforelaying. OFC shall be supplied by the railway. Blowing/Laying shall bestarted from one end and each drum laying shall be monitored afterblowing/laying and before leaving the site, trace/cable parametersfor all the fiber/ conductors shall be taken from one central locationby contractor's engineer with his own OTDR , optic talk set/measuring equipment's with railway engineer. All the equipment'sand machinery required shall be arranged by the contractor at his own cost
1500
11
17910
... More
Laying of HDPE pipe as per approved cable route plan in the excavated trench, taking due care while transporting and laying the same in the trenches or other protective works. Both the end of duct should be sealed with end plugs before laying and should remain selead till blowing is done.
1500
5
8370
... More
Excavation of trench 300 mm wide at the bottom and 1.2 mtr deep, in all normal of soils condition. This work includes clearing of route from bushes etc, covering of cable laid in trench 7 by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1.2m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1.2m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1.2m.
1000
97
97040
... More
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item 8 includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each G.P.(Cables will be maggered before and after its laying by contractor under supervision of Railway Representative and he will submit the maggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.
1000
11
11260
... More
Supply and installation of CT box for 20 Pair for Termination of Telecom Cable as per technical specification
2
3173
6347.28
... More
Splicing of fibres OFC Cable and making Splice joint with contractor's own splicing machine and tools and consumables.(Rates are for single fiber splice)
220
259
57186.8
... More
Installation of 9U rack with complete accessories as per instruction of Engineer in charge.
2
322
644
... More
Horizontal direction drilling/boring without damage of surface road using Auger Machine/Manual. The bore shall be 150 mm dia & shallbe done at the depth of minimum 1200 mm from the groundlevel. The ground level shall be considered ignoring the bankheight of the bank of the 12 road. The length of the bore shall beminimum 4 Mtrs long. this include insertion of different dia DWCpipe/ GI pipes coupling etc. as per direction of Engineer Incharge. Note:- Pipe will be supplied by railway. Contactor shallprovide all material required for boring and adequate nos. oflabours for proper laying of cables into the bore. Cable shall belaid cautiously so that it should not get damaged due to roughhandling & pressure on cable
30
1301
39039.6
... More
Wiring, drawing, fixing, laying and clipping of all telecom cable/PVC Power cable in PVC pipe/duct/Casing caping with complete fitting as per the instruction of site Engineer.
500
9
4765
... More
Laying of half round RCC pipe after laying the cables in the trenches. (Cable laying is covered separately)
-
-
14
... More
Supply and Installation of PVC channel, withcover, of size 75 mm x50 mm of 1.2 mm thickness. The installation is to be done as per instructions of site in charge.
20
264
5284.2
... More
Supply and installation of RCC cable route marker engraved and painted on both sides along the route every 50mm and route diversion as per Drg. No 4014/00/CC4 or latest/ Stone marker.
20
453
9077.2
... More
Supply and installation of 2MP Full HD night vision Dome camera (including necessary 17 enclosures, clamps, housing, fixing arrangements to fix cameras on ceiling, PF shelters, poles, gates and with 3 year OEM warranty ) (Make: should be complied MAKE IN INDIA policy) as per Technical Specification.
14
9235
129296.44
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements