NHDC Limited Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
NHDC Limited - NHDC Tender
Eprocure
Opening Date3 Nov 2021
Closing Date13 Dec 2021
Tender Amount₹ 56,36,755
Costs
EMD
Refer DocumentsDocument Cost
₹ 1,180Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_NHDC_655932_1Bid Award Id
ViewTender No
Nit No. 23/1313/2021-22 dated 01/11/2021Tender Authority
NHDC Limited ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Refurbishment of old household electrical wiring of Residential Quarters (D/E/F-Type) and Punasa field Hostel of Indira Sagar Power Station, Narmada Nagar, Distt. Khandwa (M.P.).
BOQ Items
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Group A.
435
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Group B.
640
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Group C.
619
-
-
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
40
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required 3 x 2.5 sqmm.
4596
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required 6 x 2.5 sqmm.
1723
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required 5 x 6 sqmm.
400
-
-
Power point wiring using modular accessories (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4 sq.mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid PVC casing and caping ISI marked of suitable size etc. or in medium class PVC conduit in surface or recess with 20/16 Amp. F.T. switch and socket / SS combined 20/16/6 Amp. of ISI marked and 4 sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside capping, screwless conncetor for joints as per specification for:-
On separate board, Medium point
86
-
-
Power point wiring using modular accessories (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4 sq.mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid PVC casing and caping ISI marked of suitable size etc. or in medium class PVC conduit in surface or recess with 20/16 Amp. F.T. switch and socket / SS combined 20/16/6 Amp. of ISI marked and 4 sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside capping, screwless conncetor for joints as per specification for:-
On separate board, Long point
73
-
-
Power point wiring using modular accessories (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4 sq.mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid PVC casing and caping ISI marked of suitable size etc. or in medium class PVC conduit in surface or recess with 20/16 Amp. F.T. switch and socket / SS combined 20/16/6 Amp. of ISI marked and 4 sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside capping, screwless conncetor for joints as per specification for:-
On separate board, Extra long-I
92
-
-
Power point wiring using modular accessories (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4 sq.mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid PVC casing and caping ISI marked of suitable size etc. or in medium class PVC conduit in surface or recess with 20/16 Amp. F.T. switch and socket / SS combined 20/16/6 Amp. of ISI marked and 4 sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside capping, screwless conncetor for joints as per specification for:-
On separate board, Extra long-II
91
-
-
Same board switch & socket 16 Amp. / SS combined 20/16/6 Amp.
206
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required, 1 or 2 Module (75mmx75mm)
348
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required, 4 Module (125mmx75mm)
374
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required, 6 Module (200mmx75mm)
175
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required, 8 Module (125mmx125mm)
253
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required, 12 Module (200mmx150mm)
250
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required, 5/6 amps switch.
1150
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required, 3 pin 5/6 amp socket outlet.
1150
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required, Telephone socket outlet.
100
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required, TV antenna socket outlet.
100
-
-
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
298
-
-
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
700
-
-
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required, 8 way (4 + 24), Double door.
(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
6
-
-
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required, 100 Amps.
6
-
-
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required, 63 Amps.
10
-
-
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required, 4 way (4 + 12), Double door. (But without MCB/RCCB/Isolator)
12
-
-
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required, 63 Amps.
12
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 KA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required, Single Pole.
540
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 KA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required, Triple Pole.
12
-
-
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required, 2 pair.
2002
-
-
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
2002
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements