Military Engineer Services Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date18 Jul 2024
Closing Date16 Sep 2024
Tender Amount₹ 46,69,000 
Notes
Download

Costs

Summary

Special Repair To Building No Te-02 (at Pers Living Barrack) And Special Repair To Building

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling wrought iron or mild steel work of any description as provided for Roof trusses, trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) complete all as specified and directed.

54

-

-

... More
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to I . S 1161-1979 GDE ST 240.

10450

-

-

... More
S & F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410-W(Gde-E- 250)quality-A complete all as specified and directed.

200

-

-

... More
M & L for Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165

740

-

-

... More
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillet complete.

756.9

-

-

... More
M&L 600x600x4 mm thick HPSC oceanic pre primed self embossed textured designer board water, termite and fire resistant as in ceiling or wall panelling fixed with screws as per manufracture instructions complete all as specified.

756.9

-

-

... More
S&F 605X605mm Anodised aluminium snap grid frame work for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified.

756.9

-

-

... More
Taking down cement plaster of any description on brick or stone walls, ceiling etc including rakking out joints , hacking for key , scrubbing down with water at any height etc all as specified and as directed.

819

-

-

... More
M&L for rendering in cement mortar (1:6) 10mm thick first coat on fair faces of brick walls or concrete surfaces and in cm 1:4 5mm thick second coat over first coat , mixed with water proofing compound as per manufacturer instructions, finished fair and even without using extra cement all complete as specified and as directed incl taking down existing plaster.

419.5

-

-

... More
M & L 10 mm thick rendering in cement mortar 1:6 on brick work or concrete surface, surface finished even and fair complete.

389.5

-

-

... More
M & L Preparation newly plastered surfaces and applying 1mm thick Wall care putty on surfaces of wall as per manufacture's instruction complete all as specified and directed.

1348

-

-

... More
M & L for applying two coats of oil bound distemper over a coat of primer on prepared wall putty surfaces of internal wall all as per specified and directed.

389.5

-

-

... More
M&L Two coats of exterior emulsion paint ( Apex ultima or weather coat) with primer , white or tinted on old/New surfaces of walls including prepration of old/New surfaces and washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .

419.5

-

-

... More
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and directed

57.75

-

-

... More
M&L Granite stone 18- 20 mm thick(of any type) work (table rubbed and polished) for wall lining (Veneering to wall) and laid on cill of parapit wall over 12 mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite colour as per direction of GE

21.1

-

-

... More
M & L 20 - 25 mm thick machine cut Kota stone slab in flooring or treads of steps over and including 20mm thick screed bed in cement mortar 1:6, laid and jointed with grey cement slurry mixed with pigment to match with shade of slab including rubbing complete all as specified and as directed. Note:- The size of Kota stone slab shall not less than 550 mm x 550 mm cut size, except the location where the balance portion remain less than size as specified above.

202.4

-

-

... More
Description same as per item No 19 above but as in skirting or vertical surfaces including 10 mm thick rendering in cement mortar 1:4, complete all as specified and as directed.

14

-

-

... More
M&L for Chequered cement concrete tiles 40cm x40cm x 40mm thick set, jointed and pointed in neat cement slurry in floorsetc over and including 15 mm thick screed bed in CM 1:6 including demolition complete all as specified and directed.

135

-

-

... More
M & L for machine pressed precast concrete interlocking paver block (glosy finished) any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment laid on 50 mm thick stone dust cushioning laid dry to the profile complete all as directed.(Note: Sand cushioning over will be measured & paid seperately.

205

-

-

... More
Dismantling of floor hearth or wall tilling including cement mortar bedding (but not backing) and rubbish of the premisses complete all as specified and directed.

624.6

-

-

... More
M&L non skid/mat finish ceramic colour tiles 7 to 8 mm thick(square/ rectagular) area of each tile exceeding 0.06 sq m but not exceeding 0.11 sqm (Colour and design of tiles as approved by GE), in floors/skirting etc, and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.

12

-

-

... More
M&L glazed ceramic coloured tiles size 300mm x 450 mm thick (Colour and design of tiles as approved by GE) on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.

143.1

-

-

... More
M&L glazed ceramic coloured tiles size 300x200 x 6-7 mm thick (Colour and design of tiles as approved by GE) on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.

5

-

-

... More
M & L for vitrified cerameic tiles 9 to10mm thick light shade (square/rectangular ) polished, area of each tiles not exceeding 0.36 sqm in floor/skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20 mm thick screed in cement mortar 1:4 complete all as specified and directed.

464.5

-

-

... More
Demolition of un-reinforced cement concrete in ground floors and pavigns not exc.15 cm thickness. (Below or abve ground level), complete all as specified and as directed.

55.53

-

-

... More
M&L 75mm thick PCC type C-2 (1:3:6) (using 40 mm graded crushed stone aggregate) as in plinth protection laid in panels, finished even and fair, complete all as specified and as directed.

128.1

-

-

... More
M&L PCC 1:4:8 type D-2 using (40 mm graded stone aggregate) as in foundation, sub base / mass concrete etc. complete.

34

-

-

... More
M & L 25 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate including finishing surface of concrete topping even and rough complete as in levelling work etc complete all as specified and directed.

476.5

-

-

... More
Demolition of Brick work built in cement mortar including all quoins arches pillars etc complete all as specified and directed

18

-

-

... More
M&L brick work with fly ash brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.

18

-

-

... More
Taking down shutter of any description n. exc. 1 Sqm each complete.

12

-

-

... More
Taking down shutters exc. 1.00 Sqm but not exc 2.0 sqm complete all as specified and directed.

52

-

-

... More
S & F 30 mm thick Flush shutters , solid core construction, with block board core and plywood face panels one face is covered with decorative face veneer with lipping/ frame to match fixed to chowkats complete all as specified and directed.

25.8

-

-

... More
S & F 2 nd class hard wood 35 mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass , gauze, etc, (without sash bar) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR Part-I, section 8, clause 8.24 (a) fitted to chowkats complete all as specified and directed. Note :- Glass pane and wire mesh shall be measured and paid separately in respective supply only item.

20.1

-

-

... More
Supply only Galvnised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18 mm complete as specified and directed. Note- steel wire cloth can be fixed in any type of window, ventilators or doors i.e. aluminium ,steel windows or glazed doors.

10

-

-

... More
M & L Preparation of New wood or previously untreated surfaces of any description , not otherwise description, over 10 cm width or grith apply two coat of synthetic enemel paint (ordinary tint) over a coat of pink primer complete all as specifed and directed.

53

-

-

... More
M & L for preparation of new or previously untreated steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over of redoxide zinc chrome coat complete all as specified and as directed.

128

-

-

... More
S & F powder coated aluminium ventilator cross section conforming to IS 63.5x38.10x1.5mm consisting of two partions upper portion shall have louvers with 3mm thick pin headed glass and aluminium wire cloth 0.30mm nominal dia of wire and average width of aperture 1.56m fixed with aluminium beads and securing on outer face of frame and lower portion of ventilation shall be fixed with 3mm thick pin headed glass with IDPE rubber gasket including aluminium beads, including preparation of jambs all around in CM 1:3 finishing even and smooth complete all as specified and directed.

5

-

-

... More
S & F Powder coated aluminium sliding glazed windows with three track shutter sliding (two shutters glazed and one shutter wire mesh) shall be following specification complete all as specified and as directed by Engr-in-charge. (i) Windows frame of cross section 101mm x 44mm x 1.5mm thick. (ii) Three way track for sliding shutters of cross section 91.8mm x 31.75mm x1.1mm thick. (iii) Sliding shutter frame of cross section 40 x 18 x 1mm thick. (iv) 4 mm thick tinted glass superior quality. (v) IDPE Rubber guasket for fixing of glass. (vi) Locking cleats per shutter -01 Nos. (vii) Sliding rollers per shutter - 02 Nos. (viii) Aluminium wire cloth 0.30mm nominal dia of wire and average width of aperture 1.56mm for shutters 01 Nos.

52.4

-

-

... More
S&F for PVC door frames of sizes 50 x 47 mm made out of 5 mm prelam PVC sheet reinforced with MS Square tube in opening of suitable size complete all as specified and directed.

25

-

-

... More
S&F Factory made (Prelam on both sides) solid panel PVC door shutter 30 mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall covered with heat moulded prelam PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for styles and prelam PVC sheets for top rail, lock rail and bottom rail in either side and as gap insert for top rail and bottom rail pannelling of prelam PVC sheet to be filled in the MS welded/sealed to the styles and rails with suitable PVC sheet beading and jointed together wiht solvent and fixing in the frame at site as per specification and drawing complete all as specified and directed.

9

-

-

... More
S & F 100 mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete .

84

-

-

... More
S & F aluminium 200 mm long anodised barrel tower bolts ISI marked of extruded section and fixed complete.

28

-

-

... More
S & F aluminium 150 mm long anodised barrel tower bolts ISI marked of extruded section and fixed complete.

20

-

-

... More
S & F 300 mm mild steel, ordinary rat tail rod pattern spring including roller and roller plate complete fixed to steel frame / wooden frame including necessary welding, cutting, opening of wall for fixing bracket and making good complete.

11

-

-

... More
Taking up or down existing steel tubing and connection complete for following sizes:-

-

-

-

... More
(a) 15 mm bore

100

-

-

... More
(b) 20 mm bore

50

-

-

... More
(c ) 25 mm bore

5

-

-

... More
Supplying, fixing, jointing and testing galvanised steel water tubing medium grade with all fittings such as bend, elbow, socket reducer etc fixed to walls and ceilings or laid in floors, complete for the following sizes: -

-

-

-

... More
(a) 15mm bore

100

-

-

... More
(b) 20 mm bore

50

-

-

... More
(c ) 25 mm bore

5

-

-

... More
S&F 500 Ltrs capacity rotational moulded polyethylene water storage tanks, (cylindrical vertical with closed top) hoisted and fixed in position including taking down, all as specified in SSR part I- complete.

3

-

-

... More
S&F in repair ball valve/float ball high pressure of PTMT 20mm with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed minimume weight 210 gm etc all as specified and directed.

3

-

-

... More
S & F in repairs 15 mm bore bib taps chromium plated fancy type cast copper alloy crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, and fixed complete all as specified and directed.

6

-

-

... More
S & F in repairs chromium plated fancy type stop cock/angle cock 15 mm dia cast copper alloy screwed down, high pressure, with crutch or butter fly handle screwed both ends for iron pipe or for unions and fixed, complete all as specified & directed.

12

-

-

... More
S & F in repairs 15 mm bore two way bib taps long body, chromium plated cast copper alloy long body , screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed.

3

-

-

... More
S & F in repair Bidet spray (Health faucet) with 1 meter tube and holder, complete all as specified and directed.

3

-

-

... More
Supply and fix in repair of wash hand basins, vitreous china,of size 550x400mm (flat back, or angle back type) including cutting for and pinning in ends of brackets or erecting stand exclusive of fixing of supply and waste pipe etc complete all as specified and directed.

3

-

-

... More
S & F in repairs Vitreous china wash down water closet pan (pedestal pattern), white including pedestrial pan and trap, including seat cover for pedestial pan and connecting to drain or outgoing pipe and to flushing pipe, antisyphonage pipe etc complete all as specified and directed.

3

-

-

... More
Mild steel sliding door bolts 250mm length, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed

22

-

-

... More
S&F in repair stainless steel kitchen plate rack made out of 1mm thick stainless steel of size 900 x 600 mm of best quality of approved make, complete all as specified and as directed.

3

-

-

... More
S&F in repairs of Bevelled edge mirror of 5 to 6 mm thick selected quality glass of size 600 x 450 mm mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plug with Chromium Plated brass screw and cup washers complete complete all as specified & directed.

3

-

-

... More
S& F in repairs of sheet glass shelf assembly, approved make, consisting of 5.5mm thick sheet glass shelf 60mm wide with chromium plated bracket guard and railing 500mm long complete all as specified & directed.

3

-

-

... More
S&F in repairs corner glass shelf 5.5mm thick with aluminium bracket and railing as per sample, complete all as specified and as directed.

6

-

-

... More
S&Fin repair of PVC valveless, syphonic action type flushing cistern,low/high level white with inlet ball valve float and handle including brackets complete fixrd in repair capacity of flush 10 ltrs complete all as specified and directed.

3

-

-

... More
S & F in repair Sink Mixer 15 mm CP Fancy exclusive type as per direction by Engg-in-charge, complete all as specified and directed.

3

-

-

... More
S & F in repairs of Wall mixture CP hot & cold, 15mm bore, bright finish with three joints screwed the ends for iron pipe and plugging complete all as specified and directed.

3

-

-

... More
S&F in repair 15 mm bore basin mixture Fancy Type brass chromium plated with capstan heads screwed down high pressure with or without letter ‘HOT’ or ‘COLD’ with long screwed shanks and fly-nuts, screwed for iron pipe, complete all as specified and directed.

3

-

-

... More
S&F in repair of Drapory/curtain rod 20-25mm dia of stainless steel fixed with fancy type matching pair of bracket not less than 75 grams each fixed with screw .

50

-

-

... More
S & F in repair of 15mm bore, 450mm long, PVC connections with brass unions internally threaded both ends complete fixed to iron pipe at both ends complete all as specified and directed.

6

-

-

... More
S & F in repairs of CP Brass Fancy type shower rose 125 mm dia with 125mm long CP Nipple of approved quality complete all as specified and directed..

3

-

-

... More
S&F in repair of 110mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid on wall / floor with clip complete all as specified and directed..

10

-

-

... More
S&F in repair of 75mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid on wall / floor with clip complete all as specified and directed..

20

-

-

... More
S & F in repair 110 mm dia bore PVC (SWR) bends with acess door any radius with solvent rubber ring joints, fixed complete all as specified and directed.

10

-

-

... More
M & L for complete removal of existing treatment on walls and evenly applying two coat of oil bound distemper with roller over and including a coat of putty all as specified and directed.

269.5

-

-

... More
Material & labour preparation of old surface and applying two coats of 100% Premium arcylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance , dirt resistance exterior paint of required shade (Company Depot Tintd ) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over and including a coat of putty complete. Makes :- Asian - Apex, Burger - Weather coat antidust, Nerolac -Excel, Dulax - Weather shield.

349.5

-

-

... More
S&F in repair of 18/19mm thick block boards grade 2 quality, interior grade, commercial type as in shelves and partitions of cup boards fixed with screws to under frame work inculding 6 mm thick teak wood lipping edging on all sides complete all as specified and directed.

8

-

-

... More
S & F in repair Factory made PVC cabinet of required size fabricated by joining for 18mm plain white (600 kg density) thick PVC Celuka ply fixed with each other using solvent cement adhesive and screws and 18mm thick PVC sheet as backing of cabinet fixed with screw and solvent cement adhesive etc including taking down and including batten and hinges for fixing of shutter, complete all as specified and directed.

14

-

-

... More
S & F Continuous (piano) hinges having width of flaps 40mm(when open),mild steel, bright finish or electrogalvanised complete all as specified and directed.

25

-

-

... More
Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed.

4.8

-

-

... More
M & L for Pressed steel frames for doors of size 125mm x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed

20

-

-

... More
Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc.

155

-

-

... More
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface all as specified and directed at site.

7

-

-

... More
Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.

57

-

-

... More
Taking down existing geyser of any capacity after disconnecting all necessary electrical and water supply connections and deposit to MES store yard of AGE E/M No II complete all as specified and as directed.

2

-

-

... More
Taking down existing single phase electric energy meter of any capacity after disconnecting all necessary electrical connections and deposit to MES store yard of AGE E/M No II complete all as specified and as directed.

6

-

-

... More
M&L point wiring with 1.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC conduit (medium grade) concealed in wall / ceiling with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, conceiled on walls and fixed by neans of brass screws incl modular cover plates and cover frme any size/module, for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for the following complete for One light / fan /bell controlled by one, one way switch 5/6 Amps all as specified and as directed .

103

-

-

... More
All as per item No 92 here in above , but for one 3 pin, 5/6 amps socket outlet point on independent board controlled by one, one way 5/6 amps switch

21

-

-

... More
All as per item No 92 here in above , but for one 3 pin, 5/6 amps socket outlet point on same board controlled by one, one way 5/6 amps switch

12

-

-

... More
M&L point wiring with 2.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC conduit (medium grade) concealed in wall / ceiling with and including 2.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, conceiled on walls and fixed by neans of brass screws incl modular cover plates and cover frme any size/module, for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one 15A socket point independent complete incl taking down of old unsv point wiring all as specified and directed.

10

-

-

... More
S&F in replacement of Ceiling rose three terminals surface bakelite type, AC, 50 HZ, 230V complete all as specified and directed.

46

-

-

... More
S&F modular switch 1 way 6 A , 1 module complete all as specified and directed.

145

-

-

... More
S&F modular socket 6 Amps 2/3 pin combined 2 module complete all as specified and directed.

42

-

-

... More
S&F switch modular type 16 A, 1 module complete all as specified and directed.

10

-

-

... More
S&F socket modular type multipurposes 6/16 A, 2 module complete all as specified and directed.

10

-

-

... More
S&F fan regulator stepped electronic, modular type 02 module as specifed and directed.

10

-

-

... More
S&F modular bell push type 6 A ,1 module complete all as specified and directed.

16

-

-

... More
S&F bell multi music type AC 230 volts single pole complete all as specified and directed.

16

-

-

... More
S&F surface /wall mounted LED batten (other than slim channel type) poly carbonate housing for retrofit LED tube T-8 type upto 1x22 watt, 4 feet long pre wired incl integrated electronic driver complete with all connected accessories all as specified and directed.

16

-

-

... More
S&F ultra bright LED poly carbonate tube light 4 feet long 18 to 20 watts with THD less than 15% very high effficiency suited for T-8 tube light luminare with system efficiency 120 lumens per watts. High quality polycarbonate end cap in white finish and snap fitted to the housing complete all as specified and directed.

28

-

-

... More
Supply and fixing wall mounted LED tube light fitting 10 watts comprising batten of extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver 10 W LED 2 feet long ,THD less than 15% complete all as specified and directed.

4

-

-

... More
M&L for Modular angular holder with LED Bulb 9 watts complete all as specified and as directed

7

-

-

... More
M&L for LED Bulk head fitings 6.5 watts designed for modern homes available with premium quality diffuser for glarefree light and easy to install snapfit installer complete including taking down of old CFL/bulb bulk head fitting, making good of surfaces all as specified and directed.

6

-

-

... More
S & F LED bldg security light fitting 30 watt made up of pressure die cast aluminium housing with acylic cover as diffuser with IP-66 protection complete incl mounting pipe made of GI tubing 40 mm size 1M length bend into size with mounting brackets nut bolt and washers all as specified and directed.

4

-

-

... More
S&F MCCB ,DB VTPN wall mounted double door 4 way 415 volts with facility to provide MCCB 3 pole 125 Amps 25 KA as incomer and SP/TP MCB's/Isolator as outgoing including removed old U/S DB in the wall again fixing the new DB and wall finising complete all as specified and as directed.

1

-

-

... More
S&F MCB DB SPN 4 way double door with 200 Amps rated bus bar ,230 volts, 50 Hz complete all as specifed and directed.

4

-

-

... More
S&F MCCB 3 pole 415 V 125 A Hz with rupturing capacity 25KA.

1

-

-

... More
Supply & Fix MCB SPN 32 Amps current rating 'C' series 10 KA breaking capacitycomplete all as specified and directed.

4

-

-

... More
S&F MCB DB SPN 8 way ,IP-43, IK 09, double door type with metal door with 200 Amps rated bus bar ,230 volts, 50 Hz complete all as specifed and directed.

2

-

-

... More
Supply & Fix MCB SPN 40 to 63 Amps current rating 'C' series 10 KA breaking capacitycomplete all as specified and directed.

2

-

-

... More
Supply & Fix MCB SPN 32 Amps current rating 'C' series 10 KA breaking capacitycomplete all as specified and directed.

1

-

-

... More
Supply & Fix MCB SP 6 to 32 Amps current rating 'C' series 10 KA breaking capacitycomplete all as specified and directed.

24

-

-

... More
Supply and fixing TV socket outlet complete all as specified and as directed.

3

-

-

... More
M & L sub main wiring with 2 runs of 10 sqmm main wire along with 1 run of 6 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC concealed / surface conduit (medium grade) wherever necessary with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good disturbed surfaces complete all as specified and directed. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.

18

-

-

... More
M& L sub main wiring with 2 single core,6 Sqmm, PVC insulated PVC unsheathed stranded FR LSH copper conductor cable in and including PVC concealed/ surface conduit of earth wire with 1 x 6.0 Sq mm copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly complete including taking down old sub main wiring all as specified and directed. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.

39

-

-

... More
Taking down existing exhaust fan/ceiling fan of any sweep after disconnecting necessary connection from ceiling rose to fan and deposit to MES store yard complete all as specified and as directed

12

-

-

... More
M&L for refixing ceiling fans 1200 mm sweep obtained from taking down complete incl painting with spray paint , replacing conopy ,painting of down rod , provision of two core wire 1.5 sqmm from ceiling rose to connector of fan incl making functional complete all as specified and directed.

10

-

-

... More
M&L for refixing exhaust fan 300 mm sweep obtained from taking down item complete incl painting with spray paint , replacing metallic louvers , provision of two core wire 1.5 sqmm from ceiling rose to connector of fan incl making functional complete all as specified and directed.

2

-

-

... More
Supply , fixing rigid non metallic PVC conduit fixed conceiled/on wall wherever necessary with all connected accessories 20 mm dia for cable TV connections complete all as specified and as directed

4

-

-

... More
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for laying of cable, pipes etc and getting out all excavated material in any type of soil complete all as specified and directed.

40.5

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. thick complete all as specified and directed.

12.15

-

-

... More
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.

28.35

-

-

... More
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm complete all as specified and directed.

1000

-

-

... More
M&L for river sand filling in trenches below and above/ arround UG cable for cable protection, in duct under& abovethe cables incl punning arround cable complete all as specified and directed. Note : Punned thickness shall be measured.

12.15

-

-

... More
Supplying, laying, fixing, jointing and testing LT under ground XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with aluminium conductor , multi stranded 1100 volts grade, cross-sectional area 35 sq. mm 3.5 core, ISI-7098 marked, with electric connection lugs, laid in trenches/under floor under PCC/interlocking tiles incl making good of surface with PCC/ cementing or fixed naked with walls/on poles/in ducts/in GI pipes etc and including taking down complete trenches / all as as directed at site. Note: Excavation, earth work, sand cushioning, protection tiles/brick/block shall be measured and paid seperately.

160

-

-

... More
M&L for Tubes, 'light grade,galvanised, with all fitting of size 40 mm ;laid in trenches, under floors,roads,along poles for protection of cable with all necessary fittings and sealing ends complete all as specified and directed.

12

-

-

... More
Replacement of Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground vertically to a depth not less than 2.25 meters deep below ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level connect to galvanised earth lead wire of 4.0 sqmm size by means of bolts, nuts, check nuts and washers of galvanized iron or steel up to 7.5 meter length including connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40 mm thick RCC cover 1:2:4 mix with 6mm dia nominal reinforcement @ 150 mm c/c both ways etc complete all as shown in electrical plate No 3, connected to earthing test point complete including testing on completion all as specified.

2

-

-

... More
S&F MCB DB, TPN 4 way, IP-43, IK 09, double door type with metal door, 415 V, 50 Hz, suitable for fixing MCB TPN as incomer and SP/TP MCB/Isolator as outgoing, including taking down old DB with MCBs, fixing flush to wall & making good the disturbed surfaces complete all as specified and as directed.

1

-

-

... More
S&F MCB TPN 63 Amps,10 KA breaking capacity, 'C' curve complete all as specified and directed.

1

-

-

... More
M&L for refixing electric water heater 25 Ltr capacity obtained from taking down item complete incl spray painting , replacing 2 Nos PTMT connectors , replacing 3 core 2.5 sqmm connecting wires from power point to connector of geyser incl writing MES number all as specified and directed.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.