Military Engineer Services Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date5 Sep 2024
Closing Date1 Oct 2024
Tender Amount₹ 95,00,000
Costs
EMD
₹ 1,67,500Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_672055_1Tender No
81072/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply and laying fly ash sub class ‘B’ bricks covering with width equal to length of brick as mechanical protection to cable , laid dry and flat complete all as specified and directed.
13.54
-
-
M&L for Removing excavated material to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
308.72
-
-
M&L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
403
-
-
Supply, fixing and connecting, in repair, energy saving, environmental friendly, high efficiency long life LED module with SMD LED package, max 400 W flood light enclosed in epoxy pressure die-cast aluminium housing in grey finish with heat sink for efficient thermal management, sturdiness & excellent corrosion resistant suitable for highlighting architectural features or area lighting and powered by built-In potted, isolated electronic LED driver with lower THD, Output Open / Short Circuit protection. The Luminaire shall conform to the following technical specifications:
(i) IP rating = min IP 66
(ii) Power Factor = min. 0.95
(iii) THD = max upto 10 %
(iv) CRI = min 70
(v) Surge Protection upto 10 kV with in built SPD
(vi) Lumen efficacy of LED = 145 lm/W and lumen efficacy of system = min 40000 lm (vii) Operating voltage range: 140 V - 270V
20
-
-
Supply, fixing and connecting, in repair, energy saving, environmental friendly, high efficiency long life LED module with SMD LED package, max 300 W flood light enclosed in epoxy pressure die-cast aluminium housing in grey finish with heat sink for efficient thermal management, sturdiness & excellent corrosion resistant suitable for highlighting architectural features or area lighting and powered by built-In potted, isolated electronic LED driver with lower THD, Output Open / Short Circuit protection. The Luminaire shall conform to the following technical specifications:
(i) IP rating = min IP 66
(ii) Power Factor = min. 0.95
(iii) THD = max upto 10 %
(iv) CRI = min 70
(v) Surge Protection upto 10 kV with in built SPD
(vi) Lumen efficacy of LED = 145 lm/W and lumen efficacy of system = min 33000 lm (vii) Operating voltage range: 140 V - 270V
20
-
-
Supply, fixing and connecting, in repair, energy saving, environmental friendly, long life high efficiency LED module with SMD LED package, max 200 W flood light enclosed in epoxy powder coated die-cast aluminium housing in grey finish with heat sink for efficient thermal management, sturdiness & excellent corrosion resistant with LED as light source, suitable for highlighting architectural features or area lighting and powered by built-In potted, isolated electronic LED driver with lower THD, Output Open / Short Circuit protection. The Luminaire shall conform to the following technical specifications:
(i) IP rating = IP 66
(ii) Power Factor = min. 0.95
(iii) THD = max upto 10 %
(iv) CRI 70
(v) Surge Protection upto 10 kV with in-built SPD
(vi) Lumen efficacy of LED = 140 lm/W and lumen efficacy of system = min 20000 lm (vii) Operating voltage range: 140 V - 270V
45
-
-
Supply, fixing and connecting, in repair, energy saving, environmental friendly, long life high efficiency LED module with SMD LED package, 150 W flood light enclosed in Pure polyester powder coated die-cast aluminium housing in grey finish with heat sink for efficient thermal management, sturdiness & excellent corrosion resistant with LED as light source, suitable for highlighting architectural features or area lighting and powered by built-In potted, isolated electronic LED driver with lower THD, Output Open / Short Circuit protection. The Luminaire shall conform to the following technical specifications:
(i) IP rating = IP 66
(ii) Power Factor = min. 0.95
(iii) THD = max upto 10 %
(iv) CRI 70
(v) Lumen efficacy of LED 140 lm/W and lumen efficacy of system = min 18000 lm
(vi) Operating voltage range: 140 V - 270V
50
-
-
Supply, fixing and connecting, in repair, energy saving, environmental friendly, long life high efficiency LED module with SMD LED package 100 W flood light enclosed in Pure polyester powder coated die-cast aluminium housing in grey finish with heat sink for efficient thermal management, sturdiness & excellent corrosion resistant with LED as light source, suitable for highlighting architectural features or area lighting and powered by built-In potted, isolated electronic LED driver with lower THD, Output Open / Short Circuit protection. The Luminaire shall conform to the following technical specifications:-
(i) IP rating = IP 66
(ii) Power Factor = min. 0.95
(iii) THD = max upto 10 %
(iv) CRI 70
(v) Surge Protection upto 10 kV with in-built SPD
(vi) Lumen efficacy of LED = 140 lm/W and lumen efficacy of system = min 10000 lm
(vii) Operating voltage range: 140 V - 270V
50
-
-
Supply, fixing and connecting, in repair, energy saving and environmental friendly long life LED street light of max 90 Watt, made up of pressure die cast aluminium housing with high efficiency LED as lighting source with separate driver compartment with IP-66 protection and powered by integral, isolated electronic LED driver. The Luminaire shall conform to following technical specifications:
(i) IP rating = IP 66
(ii) Power Factor = min. 0.95
(iii) THD = max upto 10 %
(iv) CRI = minimum 70
(v) Surge Protection upto 10 kV with in-built SPD
(vi) Lumen efficacy of LED 140 lm/W and lumen efficacy of system = min 10000 lm
95
-
-
Supply, fixing and connecting, in repair, energy saving and environmental friendly long life LED street light 70 Watt, made up of pressure die cast aluminium 100 housing with high efficiency LED as lighting source with separate driver compartment with IP-66 protection and powered by integral, isolated electronic LED driver. The Luminaire shall conform to following technical specifications:
(i) IP rating = IP 66
(ii) Power Factor = min. 0.95
(iii) THD= max upto 10 %
(iv) CRI = minimum 70
(v) Surge Protection upto 10 KV with in-built SPD
(vi) Lumen efficacy of LED 140 lm/W and lumen efficacy of system = min 8000 lm
90
-
-
Supply and fix junction box made of polycarbonate with IP 66/IP 69 protection of size 155 x 210 x 92 mm , 5 way having terminals for termination of cable with necessary nuts and bolts , including -02 Nos polycarbonate cable gland (01 No), DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps in and including fixing clamp of FI 50 x 6mm with necessary nuts and bolts complete including taking down of existing unserviceable junction box of any type complete all as specified and as directed.
89
-
-
Supply, laying or fixing or passing through pipe commissioning and testing of XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 volts grade of the following cross section area including suitable size lugs including taking out /dismantling of existing cable. Note:- Excavation & earth work, sand cushioning, brick protection & GI pipe where required shall be measured & paid for separately under relevant items of this BOQ.
-
-
-
10 Sqmm 4 core
1600
-
-
16 Sqmm 4 core
1100
-
-
25 Sqmm 4 core
380
-
-
35 Sqmm 3.5 core
300
-
-
50 Sqmm 3.5 core
300
-
-
70 Sqmm 3.5 core
200
-
-
95 Sqmm 3.5 core
200
-
-
120 Sqmm 3.5 core
200
-
-
150 Sqmm 3.5 core
100
-
-
M&L for GI Tubes in repair of following size, medium grade ,galvanised , with clamp of size 25x3 flat iron, welded to pipe fixed to wall/pole/ceiling or laid in floors or under road etc complete all as specified and as directed.
-
-
-
40 mm bore
40
-
-
50 mm bore
40
-
-
Supplying and fixing in repair1100 volts grade heavy duty cable PVC insulated aluminium conductor 10 sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and as directed.
100
-
-
Supply, fixing, connecting and testing of Automatic Street light switch using infrared Sensor based Nature Switch for automatic switching of street lights, Nature switch operation should be based on Natural light lux level. Required illumination level for switching on is 30 lux and for switching off 10 lux. The sensor should also have part night operation facility for 4 - 12 hours. The sensor alongwith suitable power contactor, incoming-outgoing MCBs should be enclosed in a pole/wall mounted enclosure made out of Rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-54, The circuit should be suitable enough to take 8 kw, single phase load with contactor 63 Amps conforming to IEC-60947-4-1/IS-13947-4-1 & incoming and outgoing MCBs of rating 63 Amps conforming to IEC-60898/IS-8828 and circuit wiring of minimum 16sqmm copper conductor wire in and including providing of 50x6mm flat iron clamp, necessary nuts and bolts complete including taking down existing arrangement complete all as specified and directed . Make of nature switch - Model No Swadeep-02EC8kw1P of Kakatiya Energy System or equivalent make of Bajaj/Healer,
4
-
-
Dismantling/ taking down existing street light switching system and Supply, fixing, connecting and testing of Automatic Street light switch using infrared Sensor based Nature Switch for automatic switching of street lights, Nature switch operation should be based on Natural light lux level. Required illumination level for switching on is 30 lux and for switching off 10 lux. The sensor should also have part night operation facility for 4 - 12 hours. The sensor alongwith suitable power contactor, incoming-outgoing MCBs should be enclosed in a pole/wall mounted enclosure made out of Rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-54, The circuit should be suitable enough to take 8 kw Three phase load with contactor 25 Amps conforming to IEC-60947-4-1/IS-13947-4-1 & incoming and outgoing MCBs of rating 32 Amps conforming to IEC-60898/IS-8828 and circuit wiring of minimum 10sqmm copper conductor wire in and including providing of 50x6mm flat iron clamp, necessary nuts and bolts, complete all as specified and directed by the Engr-in-charge. Make of nature switch - Model No Swadeep-02EC8kw3P of Kakatiya Energy System or equivalent make of Bajaj/Healer
4
-
-
Repair and maintenance of High mast light fitting any type/make installed on 12/15 mtr pole by means of replacing any unserviceable parts as and when required complete with labour including taking down, dismantling, reassembling and re-fixing the fitting at its original location with proper alignment and making good all defects by replacing nuts/bolts/PVC connection etc complete all as specified and directed.
Note :- (i) Defective / worn out parts/ fittings measured and paid seperately against relevant items as "supply only".
28
-
-
Repair and maintenance of Mid mast light fitting/security light fitting any type/make installed on LT/HT/mid mast poles,by means of replacing any unserviceable parts as and when required complete with labour including taking down, dismantling, reassembling and re-fixing the fitting at its original location with proper alignment and making good all defects by replacing nuts/bolts/PVC connection etc complete all as specified and directed.
Note :- (i) Defective / worn out parts/ fittings measured and paid seperately against relevant items as "supply only".
190
-
-
S&F in replacement of GI pipe bracket ,made out of GI pipe 40mm dia light grade 1.5mtr long bent to the shape 120 degrees angle all as per site requirement including MS clamps made of F1 50x6mm complete with nuts, bolts & washer as per requirement for mounting fittings complete all as specified and directed.
88
-
-
Taking out existing PCC/steel tubular LT electric poles and LT/HT old unused pole for shifting to another location for security/street light etc of any length including breaking of cement concrete foundation, necessary excavation and earth work, dismantling cross arms, M.S. clamps, insulators etc and carefully taking down existing over head conductors complete all as specified and directed.
32
-
-
Supply and erecting steel tubular poles 9 mtr long & 410SP31 complete with cast iron base plate, finial taper plug , bolts Nuts & screws complete all as specified including painting of pole with one coat red oxide primer & two coats of aluminum paint & emedded portion shall be painted with two coat of black bituminous paint complete all as specified and directed. Note :- 1. Writing pole No with yellow shade on black base using synthetic enamel paint having height of words exc 5 cm as directed is deemed to be included in the unit rate quoted against this item.
2. Excavation & earth work & PCC where required shall be measured & paid for separately under relevant items.
25
-
-
Fixing/Erecting only of old LT/HT pole duly cutting from bottom portion including painting of pole with two coats of aluminum paint & emedded portion shall be painted with two coat of black bituminous paint complete all as specified and directed.
Note :- 1. Writing pole No with yellow shade on black base using synthetic enamel paint having height of words exc 5 cm as directed is deemed to be included in the unit rate quoted against this item.
2. Excavation & earth work & PCC where required shall be measured & paid for separately under relevant items.
7
-
-
Taking down existing worn out/old/broken/Unused ACSR conductors of any size and length at any position from LT/HT poles for re-stretching or replacement with new ACSR conductor or with LT cable etc complete all as specified and directed by Engr in charge.
12
-
-
Supply, fixing and stretching new ACSR conductors of any size and type for over head LT poles including binding at site to insulator with suitable size of binding wire etc complete all as specified and directed by Engr in charge.
6
-
-
Re-stretching only of old ACSR conductors of any size and type for over head LT poles including binding at site to insulator with suitable size of binding wire etc complete all as specified and directed by Engr in charge.
6
-
-
Taking out existing broken/unserviceable stay assembly and supply and fixing new stay assembly complete with accessories and GI stay rod 20 mm dia 1900 mm long, stay wire 7/4 mm stranded galvanised including mild steel stay plate 300 mm X 300 mm x 6 mm and galvanised thimble, galvanised steel 14 mm dia 400 mm long stay bow and GI nuts, washers including loop type insulator vitreous porcelain white, brown or green big size with overall dimensions 90 mm x140 mm clearance of hole 25.5 mm complete all as specified and shown in electrical plate No. 1 of SSR part–I(2009) complete all as specified and directed
30
-
-
Supply,laying & fixing 50 mm outer dia and 38 mm inner dia double wall corrugated (DWC) pipes made of High Density Polyethylene (HDPE) with all accessories i.e. all type of joints,Sockets,Elbows,bends and End caps etc. complete all as specified and directed
570.5
-
-
Supply,laying & fixing 90 mm outer dia and 75 mm inner dia double wall corrugated (DWC) pipes made of High Density Polyethylene (HDPE) with all accessories i.e. all type of joints, Sockets, Elbows, bends and End caps etc.complete all as specified and directed
224
-
-
Material and labour for providing cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling complete all as specified and directed.
8.37
-
-
Material and labour for providing cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling complete all as specified and directed.
81.01
-
-
Material and labour for providing cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles including necessary form work and finished the surface complete all as specified and directed.
8.37
-
-
M&L for GI Tubes, of size 40mm bore, light grade ,galvanised , with clamp of 25x3 flat iron welded to pipe fixed to wall/pole/ceiling or laid in floors or under road etc complete all as specified and as directed.
54
-
-
M&L for GI Tubes, of size 50mm bore, light grade ,galvanised , with clamp of 25x3 flat iron welded to pipe fixed to wall/pole/ceiling or laid in floors or under road etc complete all as specified and as directed.
54
-
-
Taking down existing rusted/worn out MS cross arm, angle, clamps, nuts, bolts and washers and supply and fixing new MS Cross arms, bracings, supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any type, shape or as indicated and directed inclusive of one coat of red oxide primer and two coat of aluminium paint complete all as specified and directed by Engr in charge.
5
-
-
Taking down existing cracked/unserviceable Pin type insulator and supply and fixing new Pin type insulator porcelain vitreous white, brown or green including one galvanised mild steel spindle, two galvanised washers and one galvanised iron nuts 65 mm dia for 1100 volts grade complete all as specified and directed by Engr in charge.
45
-
-
Taking down existing cracked/unserviceable shackle type insulator and supply and fixing new shackle type insulator porcelain vitreous 75 mm high and 90 mm dia ball and socket type (white, brown or green) complete single disc assembly for tension with tension clamps suitable for ACSR conductor working pressure 1100 volts grade complete all as specified and directed by Engr in charge.
45
-
-
M&L Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 32 X 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 3 of MES SSR part-I(2009) :-
(a) Excavation and earth work for drilling hole for electrode in any type of Soil.
(b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter.
(c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed
(d) 40 mm nominal bore medium grade GI protection pipe 7 meter long for protection of earthing lead complete all as specified and directed.
(e) Requisite quantity of common salt and charcoal.
(f) Testing of earthing. Note:- GI strip and protection pipe from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rate as quoted by the contractor.
10
-
-
M&L earthing complete with galvanised steel earth plate electrode 600X600X6mm thick burried directly in ground (Earth pit not less than 2.25 mtr deep below the ground level with top edge of earth plate not less than 1.5 mtr below normal ground level) connected to galvanised earth wire 4mm dia as earthing lead by means of bolts, nuts, chuck nuts and washers of GI or steel all as shown in electrical plate No 3 of SSR-2009 (Part-I) including charcoal dust common salt, 20mm bore GI medium grade watering pipe funnel with wire mesh, including 15mm dia GI pipe light grade for protection of GI earth lead including PCC pit 1:2:4 type B-1 using 20mm graded stone aggregate with angle iron 40X40X5mm frame 60mm thick RCC cover with 8mm steel bars 100 mm centre to centre both ways i.e. horizontal and vertical complete all as directed by Engr in charge and testing for required value complete. Notes: (i) If earth resistance of earthing is not found satisfactory it will be redone by the contractor on his risk and cost. (ii) GI strip and protection pipe from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rate as quoted by the contractor.
10
-
-
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor 10 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and directed..
250
-
-
S&F in replacement 3 Layer PPR Pipe of outer dia 20 mm (PN-16) UV stabilised having thermal stability upto 93 degree centrigrade complete and fixed with the pole by providing FI clamps, nuts and bolts of size 25x25x3mm with nuts & bolts for protection of connecting wires, connection from junction box to light fittings, complete for all as specified and directed.
18
-
-
M&L for earth continuity conductor 32x6 mm GI strip fixed to wall or recess or chases or burried in ground or drawn in conduit pipe /pipe 50 mm dia light grade complete for all as specified and directed.
150
-
-
Dismantling of old unservicable bus bar chamber and supply, erection, testing and commissioning of outdoor type LT Bus Bar Chamber box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type Aluminium bus bars (32mm x 5mm) for looping & branch connection system .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 7 tank pre-treatment of surfaces. The bus bar chamber shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The bus bar chamber shall be made of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (01 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. The bus bar chamber shall be provided with ventilation facility in the form of louvers for better heat dissipation. (Note : The bus bar chamber Box shall be designed in such a way that adequate workable space is made available inside the compartments and the size of the chamber shall not be less than 500mm height (without base frame & canopy), 500mm width and 450mm depth).
18
-
-
S&F ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 630 Amps Complete all as specified and directed.
2
-
-
S&F ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 800 Amps Complete all as specified and directed.
2
-
-
S&F ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 1000 Amps Complete all as specified and directed.
2
-
-
Supply and fixing MCCB 4 pole 100 Amps, fixed thermal & fixed magnetic rupturing capacity 16 KA, with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
7
-
-
Supply and fixing MCCB 4 pole 160 Amps, adjustable thermal & Adjustable magnetic rupturing capacity 16 KA, with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
6
-
-
Supply and fixing MCCB 4 pole 200 Amps, adjustable thermal & Adjustable magnetic rupturing capacity 25 KA, with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
7
-
-
Supply and fixing MCCB 4 pole 250 Amps, adjustable thermal & Adjustable magnetic rupturing capacity 36 KA, with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
4
-
-
Supply and fixing MCCB 4 pole 315 Amps, adjustable thermal & Adjustable magnetic rupturing capacity 35/36 KA with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
3
-
-
Supply and fixing MCCB 4 pole 400 Amps, adjustable thermal & Adjustable magnetic rupturing capacity 50 KA with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
3
-
-
Supply and fixing MCCB 4 pole 630 Amps, adjustable thermal & Adjustable magnetic rupturing capacity 50 KA, with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
2
-
-
Drilling (Horizontally) existing road ( Maximum 10 mtr wide) suitable for passing GI tubing upto 80/100mm and making good the disturbed surfaces complete all as specified and directed.
30
-
-
Re - stretching only existing ACSR of any size on HT/ LT pole including binding the ACSR with insulators, aluminium binding wire complete all as specified and as directed. Note : (i) The above work includes pruning of tree branches falling around the conductors (ii) One length shall be measured for single conductors/GI wire.
12800
-
-
S&F cable jointing kit 1100V grade cable for straight through joint,, complete with jointing materials and accessories suitablle for 3.5/4 core XLPE armoured aluminium conductor cable 25 to 95 SQMM, all as specified and directed.
60
-
-
-ditto- but 120 to 240 SQMM.
60
-
-
Scrubbing of existing paints of existing LT panel board, LT feeder Pillar boxes, LT bus bar chamber paints of any specification and removing old paints and preparation of surfaces for painting complete and M&L for painting of LT Panels, LT Feeder pillar boxes, LT bus bar chambers internaly and externaly with one coat of superior quality smoke grey paint to achieve fine finishing complete all as specified and directed by Engr - in charge at site.
40
-
-
Dismantling of old unserviceable doors, back sheets, side sheet of LT panels, bus bar chamber or feeder pillar box installed at various places by cutting/descrewing after making the system disconnected from Elect supply and M&L for fabrication of doors/frames/ partition, bottom sheet by bending hot or cold, making holes, notching, welding of MS black sheet for LT panel board, bus bar chamber, feeder pillar box made out of 2 mm thick mild steel sheet including providing hinges for opening or closing of door, making handles, locking arrangement and painting of sheet both side with superior quality smoke grey paint after applying a coat of red oxide primer and matching with the existing complete all as specified and directed by the Engr - in-charge at site. Note : The cost of disconnecting of LT cable and earth strip and reconnecting the same after repair work shall be deemed to be inclussive in the unit quoted rates.
40
-
-
Dismantling/ taking down of existing bus bar of any type and supply and fixing bus bar made out of aluminium with coulour coded sleeves (Red, Yellow, Blue and black) with necessary bus bar insulators and nuts bolts of suitable size as required at site complete all as specified and directed
30
-
-
Disconnecting, dismantling of existing old unserviceable LT Panel/Feeder pillar box and supply, erection, commissioning and testing of outdoor type LT Panel, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type main copper bus bars of 600 Amps, looping & branch connection system shall be made with suitable rating copper bus bar having sleeves of colour coded .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 7 tank pre-treatment of surfaces. The LT Panel shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-66 and general construction conforming to IS : 13947. The LT Panel shall be made out of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (02 layers) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. All incoming MCCBs shall be marked with location and rating of MCCBs. The Feeder Pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation in and including dismantling of old unserviceable LT Panel complere and including the followings :
2
-
-
CONTROL WIRING : All control wirings shall have to be carried out with 1100 volts rated FR grade PVC insulated multi-flexible type copper wire of cross sectional area 1.50Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges.
-
-
-
CABLE ALLEY- Cable alley shall be provided in both side of the panel of suitable space for all incoming and outgoing cables. Cable terminals shall be provided for conecting of all incoming and outgoing cables,
-
-
-
INCOMING :- MCCB 400 Amps, 4 pole, 415 volts, 50 kA, 50 Hz, microprocessor based, electronic release.
-
-
-
OUTGOING : (a) MCCB 200 Amps, 4 pole, 415 volts, 25 KA, 50 Hz, adjustable thermal & Adjustable magnetic, Ics = 100%Icu - 01 No
(b) MCCB 160 Amps, 4 pole, 415 volts, 25 KA, 50 Hz,adjustable thermal & Adjustable magnetic, Ics = 100%Icu - 01 No
(c) MCCB 100 Amps, 4 pole, 415 volts, 25 KA, 50 Hz, adjustable thermal & Adjustable magnetic, Ics = 100%Icu - 04 Nos
(d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 No. (e) Digital Ammeter 96mm x 96mm suitable to read 0 to 630 Amps, accuracy class 1% - 01 No. (f) Current transformer (CT) of rating 630/5, tape wound, rated burden 5 VA - 03 Nos (g) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply - 1 set of 03 Nos (Red - 01, Yellow- 01, Blue - 01) (h) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos. (j) Copper bus bar 20mm wide,5mm thick, of suitable length duly mounted on FRP bus bar insulators and marked with standard colour coded sleeves / tapes for all outgoing MCCBs - 04 Nos.
-
-
-
(k) LED Pilot Lamp of following colours : (i) RED - 01 No, YELLOW - 01 No, BLUE - 01 No.
(l) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber. (m) Power contactor four pole with coil voltage 230 volt of capacity 25 Amps 50 cycles. - 01 No
(n) Time switch microrex analog time switch -01 No
(o) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI approved Manufacturer (The panel shall not be less than 2.5 Sqm front area)
-
-
-
Note : Panel will be manufactured by CPRI approved Manufacturer as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of foundation is deemed to be included in the quoted rates.
-
-
-
Disconnecting, dismantling of existing old unserviceable LT Panel/Feeder pillar box and supply, erection, commissioning and testing of outdoor type LT Panel, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type main copper bus bars of 400 Amps, looping & branch connection system shall be made with suitable rating copper bus bar having sleeves colour coded .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 7 tank pre-treatment of surfaces. The LT Panel shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-66 and general construction conforming to IS : 13947. The LT Panel shall be made out of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (02 layers) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. All incoming MCCBs shall be marked with location and rating of MCCBs. The Feeder Pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation in and including dismantling of old unserviceable LT Panel complete and including the followings :
2
-
-
CONTROL WIRING : All control wirings shall have to be carried out with 1100 volts rated FR grade PVC insulated multi-flexible type copper wire of cross sectional area 1.50Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges.
-
-
-
CABLE ALLEY- Cable alley shall be provided in both side of the panel of suitable space for all incoming and outgoing cables. Cable terminals shall be provided for conecting of all incoming and outgoing cables,
-
-
-
INCOMING :- MCCB 250 Amps, 4 pole, 415 volts, 50 kA, 50 Hz, microprocessor based, electronic release.
-
-
-
OUTGOING : (a) MCCB 160 Amps, 4 pole, 415 volts, 36 KA, 50 Hz, adjustable thermal & Adjustable magnetic, Ics = 100%Icu - 01 No
(b) MCCB 100 Amps, 4 pole, 415 volts, 25 KA, 50 Hz,adjustable thermal & Adjustable magnetic, Ics = 100%Icu - 02 Nos
(c) MCCB 63 Amps, 4 pole, 415 volts, 16 KA, 50 Hz, fixed thermal & fixed magnetic, Ics = 100%Icu - 03 Nos
(d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 No. (e) Digital Ammeter 96mm x 96mm suitable to read 0 to 630 Amps, accuracy class 1% - 01 No. (f) Current transformer (CT) of rating 630/5, tape wound, rated burden 5 VA - 03 Nos (g) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply - 1 set of 03 Nos (Red - 01, Yellow- 01, Blue - 01) (h) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos.
-
-
-
(j) Copper bus bar 20mm wide,5mm thick, of suitable length duly mounted on FRP bus bar insulators and marked with standard colour coded sleeves / tapes for all outgoing MCCBs - 04 Nos.
(k) LED Pilot Lamp of following colours : (i) RED - 01 No, YELLOW - 01 No, BLUE - 01 No.
(l) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber. (m) Power contactor four pole with coil voltage 230 volt of capacity 25 Amps 50 cycles. - 01 No
(n) Time switch microrex analog time switch -01 No
(o) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI approved Manufacturer(The panel shall not be less than 2.5 Sqm front area)
-
-
-
Note : Panel will be manufactured by CPRI approved Manufacturer as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of foundation is deemed to be included in the quoted rates.
-
-
-
Supply and fixing in repair square type capacitor of 1 kVAr heavy duty complete all as specified and directed.
17
-
-
Supply and fixing in repair square type capacitor of 2 kVAr heavy duty complete all as specified and directed.
12
-
-
Supply and fixing in repair square type capacitor of 3 kVAr heavy duty complete all as specified and directed.
10
-
-
Supply and fixing in repair square type capacitor of 4 kVAr heavy duty complete all as specified and directed.
5
-
-
Supply and fixing in repair square type capacitor of 5 kVAr heavy duty complete all as specified and directed.
6
-
-
Supply and fixing in repair square type capacitor of 7.5 kVAr heavy duty complete all as specified and directed.
6
-
-
Supply and fixing in repair square type capacitor of 10 kVAr heavy duty complete all as specified and directed.
4
-
-
Supply and fixing in repair square type capacitor of 12.5 kVAr heavy duty complete all as specified and directed.
4
-
-
Supply and fixing in repair square type capacitor of 15 kVAr heavy duty complete all as specified and directed.
2
-
-
Supply and fixing in repair square type capacitor of 20 kVAr heavy duty complete all as specified and directed.
2
-
-
S&F in repair Current transformer for APFC panel CT 25/5 A, CL1, 5VA complete all as specified and directed.
2
-
-
S&F in repair Current transformer for APFC panel CT 50/5 A, CL1, 5VA complete all as specified and directed.
2
-
-
S&F in repair Current transformer for APFC panel CT 75/5 A, CL1, 5VA complete all as specified and directed.
2
-
-
S&F in repair Current transformer for APFC panel CT 100/5 A, CL1, 5VA complete all as specified and directed.
2
-
-
Schedule of credit amount of Rs 207510.00 shall be deducted during AOC to arrive contract amount.
-
-
-