Military Engineer Services Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Military Engineer Services - MES Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date5 Sep 2024
Closing Date12 Dec 2024
Tender Amount₹ 4,05,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(a) Lump sump amount worked out by the contractor for construction of sewage sump well of 4.00 metre dia and 7.50 metre depth complete all as specified and as shown on drawings.

1

-

-

... More
Lump sum price worked out by the contractor for EXCAVATION AND EARTH WORK as listed in Schedule ‘A’ Part- II (Ref prepriced schedule attached seperately)

1

-

15084.4

... More
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part- III (Ref prepriced schedule attached seperately)

1

-

6832.12

... More
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part- IV (Ref prepriced schedule attached seperately)

1

-

65898.14

... More
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part- V (Ref prepriced schedule attached seperately)

1

-

4276202.68

... More
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part- VI (Ref prepriced schedule attached seperately)

1

-

462677.6

... More
Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part- VII (Ref prepriced schedule attached seperately)

1

-

18950.35

... More
SCH 'A' Pt - VIII (MISCELLANEOUS PARTS)

-

-

-

... More
S&F, Gun metal stop valve, half turn with lever arm, screwed both ends for iron pipe 20mm dia.

4

-

-

... More
S&F, Stop valve, fancy, angular type, brass chromium plated, screwed down, high pressure, screwed both ends for irn pipe 15mm dia.

4

-

-

... More
S&F brass chromium plated, shower rose of dia, not less than 50mm with swivel joints and arm length not than 150mm screwed for iron pipe 15mm dia.

2

-

-

... More
Supply & laying in trenches, aligning and jointing of NP-2 class, RCC pipes 150 mm bore dia with socket & spigot ends, ISI Marked (IS-458), with rubber gaskets (EPDM/SBR) for sewer lines as per IS: 5382 (including cost of rubber gaskets, lubricants etc), testing of the sewer pipe line with water test (including cost and conveyence of water to site) etc complete as specified and directed.

2428.73

-

-

... More
Supply & laying in trenches, aligning and jointing of NP-2 class, RCC pipes 200 mm bore dia with socket & spigot ends, ISI Marked (IS-458), with rubber gaskets (EPDM/SBR) for sewer lines as per IS: 5382 (including cost of rubber gaskets, lubricants etc), testing of the sewer pipe line with water test (including cost and conveyence of water to site) etc complete as specified and directed.

1332

-

-

... More
Supply & laying in trenches, aligning and jointing of NP-2 class, RCC pipes 250 mm bore dia with socket & spigot ends, ISI Marked (IS-458), with rubber gaskets (EPDM/SBR) for sewer lines as per IS: 5382 (including cost of rubber gaskets, lubricants etc), testing of the sewer pipe line with water test (including cost and conveyence of water to site) etc complete as specified and directed.

615.08

-

-

... More
Supply & laying in trenches, aligning and jointing of NP-2 class, RCC pipes 300 mm bore dia with socket & spigot ends, ISI Marked (IS-458), with rubber gaskets (EPDM/SBR) for sewer lines as per IS: 5382 (including cost of rubber gaskets, lubricants etc), testing of the sewer pipe line with water test (including cost and conveyence of water to site) etc complete as specified and directed.

814

-

-

... More
Laying only in trenches, aligning and jointing of NP-2 class, RCC pipes 150 mm bore dia with socket & spigot ends, ISI Marked (IS-458), with rubber gaskets (EPDM/SBR) for sewer lines as per IS: 5382 (including cost of rubber gaskets, lubricants etc), testing of the sewer pipe line with water test (including cost and conveyence of water to site) etc complete as specified and directed.

461

-

-

... More
Laying only in trenches, aligning and jointing of NP-2 class, RCC pipes 200 mm bore dia with socket & spigot ends, ISI Marked (IS-458), with rubber gaskets (EPDM/SBR) for sewer lines as per IS: 5382 (including cost of rubber gaskets, lubricants etc), testing of the sewer pipe line with water test (including cost and conveyence of water to site) etc complete as specified and directed.

94

-

-

... More
Supply & laying in trenches, aligning and jointing of NP-2 class, RCC pipes 250 mm bore dia with socket & spigot ends, ISI Marked (IS-458), with rubber gaskets (EPDM/SBR) for sewer lines as per IS: 5382 (including cost of rubber gaskets, lubricants etc), testing of the sewer pipe line with water test (including cost and conveyence of water to site) etc complete as specified and directed.

176

-

-

... More
Laying only in trenches, aligning and jointing of NP-2 class, RCC pipes 300 mm bore dia with socket & spigot ends, ISI Marked (IS-458), with rubber gaskets (EPDM/SBR) for sewer lines as per IS: 5382 (including cost of rubber gaskets, lubricants etc), testing of the sewer pipe line with water test (including cost and conveyence of water to site) etc complete as specified and directed.

28

-

-

... More
M & L for preparation of newly plastered wall surfaces & applying two coats of cement base paints over one coat of exterior wall primer complete all as specified and diirected

1747

-

-

... More
S & F roof trusses (framed), trusses, purlin, crane gantries, rails and fastenings and heavy bracket framing (beams, tee, angle, channel or flat sections) including distance pieces, cleats etc (welded/riveting) conforming to Fe-410-W (Gde-E250) quality 'A' complete all as specified and directed.

177

-

-

... More
M & L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer of surfaces of any description, over 10cm in width or girth,not otherwise complete all as specifed and directed.

21.72

-

-

... More
S & F mild steel plates plain, 5 mm thick for manhole cover plates complete all as specifed and directed.

28

-

-

... More
S & F 32 mm GI pipe medium grade galvanised with all fittings and fixed complete all as specifed and directed.

50

-

-

... More
S & F 25 mm GI pipe medium grade galvanised with all fittings and fixed complete all as specifed and directed.

40

-

-

... More
M & L for hardcore of gauge n.exc 63 mm, with broken stone or boulders seposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface complete all as specifed and directed

20.4

-

-

... More
M & L 75 mm thick cement conceret 1:2:4 type B-2, using 40 mm graded stone aggregate complete all as specifed and directed

136

-

-

... More
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CMM with service value 6.00 BEE. Five star rated with brushless direct current motor complete all as specifed and directed.

3

-

-

... More
S & F exhuast fan electric single phase AC 240 Volts 50 Hz supply, heavy duty, corrosion resistant suitable for areas containing corrosive fumes, 450 mm weep siize 4 pole with louvers and connecting, including provision of 3 core bexible PVC insulated multi-stranded copper conductor of sign 0.50 Sqm from ceiling connector to fan complete all as specifed and directed.

3

-

-

... More
S & F of MCB, 240V, breaking capacity 10 KA, with characteristic 'B', 18-8828 marked, Single pole, 2/2.5 Amp complete all as specifed and directed

4

-

-

... More
S & F of MCB, 240V, breaking capacity 10 KA, with characteristic 'B', 18-8828 marked, Single pole, 5/6 Amp complete all as specifed and directed

4

-

-

... More
Supply, lay, connecting and testing complete of ductile Iron pressure pipe (151 marked) (15-8329-2000, Reaffirmed-2005 Edition 4.1) of 200 mm bore with spigot and socket ends, suitable for push on joints in standard working lengths supplied with rubber gasket duly "ISI marked for water, class-K-7 with camant mortar lining Inside and metalic zinc coating with finishing layer of bluminous paint on outside the pipe without polyethylene sleeve but including "Push-on- joint supplied with "151" marked EPDM rubber gasket conforming to 15-5382-1985 (Reaffirmed-2003) with dual hardness of Type-2 (Bulb) and Type-5(Heel) quality complete all as specifed and directed.

1310

-

-

... More
Supply, lay, connecting and testing complete of ductile Iron pressure pipe (151 marked) (15-8329-2000, Reaffirmed-2005 Edition 4.1) of 150 mm bore with spigot and socket ends, suitable for push on joints in standard working lengths supplied with rubber gasket duly "ISI marked for water, class-K-7 with camant mortar lining Inside and metalic zinc coating with finishing layer of bluminous paint on outside the pipe without polyethylene sleeve but including "Push-on- joint supplied with "151" marked EPDM rubber gasket conforming to 15-5382-1985 (Reaffirmed-2003) with dual hardness of Type-2 (Bulb) and Type-5(Heel) quality complete all as specifed and directed.

154

-

-

... More
Supply, lay, connecting and testing complete of ductile Iron pressure pipe (151 marked) (15-8329-2000, Reaffirmed-2005 Edition 4.1) of 100 mm bore with spigot and socket ends, suitable for push on joints in standard working lengths supplied with rubber gasket duly "ISI marked for water, class-K-7 with camant mortar lining Inside and metalic zinc coating with finishing layer of bluminous paint on outside the pipe without polyethylene sleeve but including "Push-on- joint supplied with "151" marked EPDM rubber gasket conforming to 15-5382-1985 (Reaffirmed-2003) with dual hardness of Type-2 (Bulb) and Type-5(Heel) quality complete all as specifed and directed.

407

-

-

... More
Labour charges of laying only DI Pipe 250 mm dia class K-7 with spigot and socket ends complete all as specifed and directed.

44

-

-

... More
Taking down the existing DI Pipe line 200 mm dia with fittings with spigot and socket ends and testing the serviceability of DI pipe lines and relaying with repairs the same location complete all as specifed and directed.

273

-

-

... More
Labour charges of laying only DI Pipe 200 mm dia class K-7 with socket and spigot ends complete all as specifed and directed.

297

-

-

... More
Taking down the existing DI Pipe line 150 mm dia with fittings with spigot and socket ends and testing the serviceability of DI pipe lines and relaying with repairs the same location complete all as specifed and directed.

528.8

-

-

... More
Labour charges of laying only DI Pipe 150 mm dia class K-7 with socket and spigot ends complete all as specifed and directed.

1813.5

-

-

... More
Taking down the existing DI Pipe line 100 mm dia with fittings with spigot and socket ends and testing the serviceability of DI pipe lines and relaying with repairs the same location complete all as specifed and directed.

583.2

-

-

... More
Labour charges of laying only DI Pipe 100 mm dia class K-7 with socket and spigot ends complete all as specifed and directed.

770

-

-

... More
Supply, lay, connecting and testing complete of ductile iron pressure pipe fittings (ISI marked) (IS-9523-2000, Reaffinned-2003) with spigot and socket ends, suitable for push on joints, supplied with a rubber gasket duly ISI marked for water, gas and sewage suitable for DI pipe class-K-7 with cement mortar lining inside as per Annexure-C of IS-0623-2000 and metallic zinc coating with finishing layer of bituminous paint on outside the asing as per Annexure-C of IS-9523-2000 without polyethylene sleeve but including "Push-on-joint" supplied with ISI marked EPDM rubber gasket conforming to IS-5382-1985 (Reaffirmed-2003) with dual hardness of Type-2 (Bulb) and Type-5(Heel) quality complete all as specifed and directed.

5264

-

-

... More
Fixing only CI Reflux valve 200 mm dia (NRV) of dismantling and testing, connecting and testing reflux valve with bypass arrangement and flanged ends drilled suitable for bore of pipe complete with nuts, bolts, washers, rubber gasket, etc complete all as specifed and directed.

2

-

-

... More
Supplying, fixing and testing of CI reflux valve (NRV) (ISI Marked) with by pass arrangement suitable for 150mm dia Ranged joint complete with nuts, bolts and washers complete all as specifed and directed.

1

-

-

... More
Fixing only CI Reflux valve 150 nmm dia (NRV) of dismantling and testing, connecting and testing reflux valve with bypass arrangement and flanged ends drilled suitable for bore of pipe complete with nuts, bolts, washers, rubber gasket, etc complete all as specifed and directed.

1

-

-

... More
Fixing only electric driven centrifugal pumpset 15 LPS, 45 M head comprising casing pump including dismantling the pump set and electric motor checking the servicebility, greasing , revarnishing and reassembling testing and commissioning complete all as specifed and directed.

2

-

-

... More
Fixing only electric driven centrifugal pumpset 15 LPS, 35 M head comprising casing pump including dismantling the pump set and electric motor checking the servicebility, greasing , revarnishing and reassembling testing and commissioning complete all as specifed and directed.

2

-

-

... More
Fixing and lowering only electric driven vertical submersible pumpset 15 LPS, 35 M head pump including dismantling the pump set and electric motor checking the servicebility, greasing , and reassembling testing and commissioning complete all as specifed and directed.

4

-

-

... More
Supplying, lowering and testing of Gl water tubing 80mm bore, heavy grade with and including all fittings long threaded heavy grade socket in length of 3 metre with leak proof jointing materials and jointing as column pipe, lowering in bore well all as required and complete all as specifed and directed at site

3

-

-

... More
Supply and fixing holding power clamp 02 Nos on tube well for column pipe fabricated out of MS flat Iron 100X10mm made to shape, drilling with and Including nuts, bolts & washers etc complete all as specifed and directed.

97

-

-

... More
Supplying, faxing and testing of cast iron reflux valve (NRV) sultable for 80mm dia flanged joint complete with nuts, bolts and washers complete all as specifed and directed.

3

-

-

... More
Supplying, fixing and testing of slim seal butterfly Rs valve with iron wheel head, both ends flanged for Iron pipe and fixed complete with nuts, bolts and washers complete all as specified for 80mm complete all as specifed and directed.

6

-

-

... More
S&F, Pressure gauge diaphragm type up to 10 Kg/Sqcm complete all as specifed and directed.

6

-

-

... More
Installation, testing and commissioning only outdoor type, floor mounted, LT panel board, cubicle type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved copper bus bar of rating 200 Amps for phases and neutral installed on porcelain insulators after removing the existing rusted portion of MS sheet and duly powder coated painted, replacing the hinges and checking the serviceability of the complete Panel board including making serviceable the existing in store panel and rewiring if any requirement of accessories to replacement testing , commissioing complete all as specified and directed. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15mm CRCA MS sheet and 40X40X6mm thick MS angle iron frame work, front opening type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including Internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS-694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sqmm and comprising of followings Note: Cost required to make the LT panel serviceable shall deemed to be included in quoted rates by the contractor.

6

-

-

... More
Item 8.47 contd/-... INCOMINGS (a) MCCB 415 Vol. 63 Amp, rating 4 Pole Service Breaking Capacity 25 KA-1 No OUTGOINGS (b) MCCB 63 Amps, four pois, 415 voa, 25 KA nipturing capacity-01 No (Outgoing) (c) Digital 0-100 Amps, 96mm x 96mm Square dial flush type, ISI marked with selector switch 3way and current transformer -01 Set. (d) Digital 0-500 Amps, 96mm x 96mm Square dial flush type, ISI marked with rotary selecter switch 3way-01 Set. (e) Phase indicating LED lamps (R-Y-B) -01 Set (f) Supply & fixing of fully Automatic star delta starter suitable for submersible pump set mentioned in No 8.36 here-in-before complete under voltage and overload protection. Single phase preventer and mounting in main electnc panel and also including necessary wiring with PVC insulated and unsheathed copper conductor cable multistranded of suitable size, concealed in light grade GI or fexible pipe all as spected and directed -01 No Each

-

-

-

... More
Installation, testing and commissioning only Indoor type, floor mounted, LT panel board, cubicle type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved copper bus bar of rating 200 Amps for phases and neutral installed on porcelain insulators after removing the existing rusted portion of MS sheet and duly powder coated painted, replacing the hinges and checking the serviceability of the complete Panel board including making serviceable the existing in store panel and rewiring if any requirement of accessories to replacement testing , commissioing complete all as specified and directed. The panel shall be dust and vermin proof IP-54 class protection and made out of 16mm CRCA MS sheet and 25X25X6mm thick MS angle iron frame work, front opening type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including Internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS-694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sqmm and comprising of followings Note: Cost required to make the LT panel serviceable shall deemed to be included in quoted rates by the contractor.

6

-

-

... More
Item 8.49 contd/-... INCOMINGS (a) MCCB 415 Volts, 100 Amp, rating 4 Pole, with thermal magnetic base release, Service Breaking capacity 25KA-1 No. (b) Digital multi function Panel Mounted Meters for Energy metering, monitoring and management system suitable for LT 3 phase 4 wire applicatons, using micro-controllers and non volatile memory and providing anti tamper features and communication facitlity at high accuracy with accuracy for active energy as per IS:13779:99/IEC-61036, CL 1.0 operating temperature -10 to + 55°C, relative humidity 95% non condensing, 96x96x86 mm or nearer size 3 line backlit display of 6 digit each to display voltage, current, active power, reactive power, apparent power factor frequency and other meters, digit height 8 mmX4.8 mm, Protection 2x IP-54 with all necessary CTs, PTs and rument, fuses and wiring Make HPL SOCOMEC del Ctem/A2 or equivalent- 1 No OUTGOINGS (c) MCCB, 63 Amps, triple pole, 415 volts, 25 KA caturing capacity-02 Nos (Outgoing). (d) MCCB, 63 Amps, triple pole, 415 volts, 25 KA caturing capacity-02 Nos (Outgoing). (e) Supply & fixing Automatic star delta starter suitable for centrifugal pump set mentioned in items 8.34 & 8.35 here-in-before above complete with under voltage and overload protection, Single phase preventer and mounting in main electric panel and o including necessary wiring with PVC Insulated unsheathed copper conductor cable multistranded of suitable size, concealed in light ide GI or flexible pipe all as specified and directed.

-

-

-

... More
Supply, installtion and testing of Altoch Dosing System (Model ADS - I) or equivelent comprising Non-metallic solution tank of capacity 100 ltrs with motor driven agitator to maintain uniform suspension throughout the tank with PE/FRP Lid & Level Gauge along with Single Phase Electric motor and Agitator with shaft & blade in Plastic - mounted on Tank. Lid must have port hole for pouring Calcum Hypochlorite and water when necessary. Lid must have provision for mounting dosing pump on the lid/wall alongwith Decrin Dosing Pump, (Model 96NGQ51 or equivelent) comprising motor driven reciprocating pump chemical feeder for injecting Calcium Hypochlorite employing motor-driven reciprocating chemical pump having output of 2 U.S. GPD to 40 U.S GPD and adjustable high pressure of up to 100 PSI all complete.

2

-

-

... More
Dismantling, the exsiting the soundproof canopy Diesel Engine Driven Generating Set capable of delivering 62.50 KVA, water cooled, 415 Volts (AC three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum from existing location, Water cooling system, exhasust system, cylinder head assy, alternator, Dynamo, Complete fuel control system alongwith fuel injector, fuel injection pump, lubricating system, starting system and cleaning the all accessories,and replacing the engine gasket, cleaning the radiator assembly, drain out the existing lubricating oil, oil pump, calibriation of fuel injection pump alongwith fuel injector, replacing of Oil and fuel filter, cleaning the fuel tank, servicing the all moving parts and reassembling the all accessories , rewiring the starting system, replaced genset control panel, replaced the sound proof sponzy kit, Control battery 12V, re surfacing the rusted canopy complete, repainting complete portion, refilling the radiator coolent, Engine oil ,testing the DG set various load capacity testing and commissioning of manufacturer or OEM Manufactured complete all as specified and directed.

2

-

-

... More
Fixing and only including testing and commissioning of factory made and tested, indoor type, floor mounted, LT panel board, cubicle type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved copper bus bar of rating 200 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 1.6mm CRCA MS sheet and 25X25X6mm thick MS angle iron frame work, front opening type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS-694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sqmm. removing the existing rusted portion of MS sheet and duly powder coated painted, replacing the hinges, defective contactor etc and checking the serviceability of the complete Panel board including making serviceable the existing store panel and rewiring if any required complete all as specified and directed Note:To Make the LT panel serviceable deemed to be include in quoted rates by the contractor

2

-

-

... More
Item 8.53 contd/-... INCOMINGS (a) MCCB 415 Volts, 125 Amp. rating 4 Pole, Service Breaking Capacity 25 KA-1 No. OUTGOINGS (b) MCCB, 100 Amps, four pole, 415 volts, 25 KA capturing capacity-02 Nos. (c) Digital multi function Panel Mounted Meters for Energy metering, monitoring and management system suitable for LT 3 phase 4 wire applications, using micro-controllers and non volatile memory and providing anti tamper features and communication facility at high accuracy with accuracy for active energy as per IS-13779.99/EC-61036, CL 1.0, operating temperature -10 to +55°C, relative humidity 95% non condensing, 96X95X86 mm or nearer size, 3 line backlit display of 6 digit each to display voltage, current, active power, reactive power, apparent power, power factor frequency and other parameters, digit height 8 mmX4.8 mm, Protection index IP-54 with all necessary CTs, PTs and instrument, fuses and wiring Make HPL SOCOMEC model ClemfA2 or equivalent-1 No. (e) Phase indicating LED lamps (R-Y-B)-01 Set. (f) Supply & fixing of fully Automatic star delta starter suitable for pump set mentioned in item No 30 here- in-after complete with under voltage and 'overload protection, Single phase preventer and mounting In main electric panel and also including necessary wiring with PVC insulated and unsheathed copper conductor cable multistranded of suitable size, concealed in light grade GI or flexible pipe all as specified and directed-02 Nos Each.

-

-

-

... More
Fixing and only including testing and commissioning of actory made and tested, outdoor type, floor mounted, LT panel board, cubicle type suitable for 415 volls, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved copper bus bar of rating 200 Amps for phases and neutral Installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15mm CRCA MS sheet and 50X50X6mm thick MS angle iron frame work, front opening type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC Insulated multi stranded copper conductor cable 1100 Volt grade IS-694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sqmm. removing the existing rusted portion of MS sheet and duly powder coated painted, replacing the hinges, defective contactor etc and checking the serviceability of the complete Panel board including making serviceable the existing in store panel and rewiring if any required complete all as specified and directed Note:To Make the LT panel serviceable deemed to be include in quoted rates by the contractor.

2

-

-

... More
Item 8.55 contd/-... INCOMINGS (a) MCCB 415 Volts, 100 Amp, rating 4 Pole, Service Breaking Capacity 25 KA-1 No OUTGOINGS (b) MCCB, 63 Amps, four pole, 415 volts, 25 KA rupturing capacity-02 Nos (Outgoing). (c) Digital multi function Panel Mounted Meters for Energy metering, monitoring and management system suitable for LT 3 phase 4 wire applications, using micro-controllers and non volatile memory and providing anti tamper features and communication facility at high accuracy with accuracy for active energy as per IS-13779.99/EC-61036, CL 1.0, operating temperature -10 to +55°C, relative humidity 95% non condensing, 96X96X86 mm or nearer size, 3 line backlit display of 6 digit each to display voltage, current, active power, reactive power, apparent power, power factor frequency and other parameters, digit height 8 mmx4.8 mm, Protection Index IP-54 with all necessary CTs, PTs and instrument, fuses and wiring Make HPL SOCOMEC model CtemfA2 or equivalent-1 No (e) Phase indicating LED lamps (R-Y-B)-01 Set (f) Supply & fixing of fully Automatic star delta starter suitable for pump set mentioned in item No 31 & 32 here- in-after complete with under voltage and 'overload protection, Single phase preventer and mounting In main electric panel and also including necessary wiring with PVC insulated and unsheathed copper conductor cable multistranded of suitable size, concealed in light grade GI or flexible pipe all as specified and directed-02 Nos Each.

-

-

-

... More
Fixing only electric driven Non clogging sewage centrifugal pump of discharge 60Cum per hours and 40 metre head horizontal shaft single suction pump with back pullout type design and suitable for solid size upto 65mm impeller made of phosphor bronze, deep groove bell bearings, including electric motor of suitable capacity class F insulation 415V, 50Hz, suction size 150mm and delivery size 150mm bore, complete and mounted on common MS base frame and foundations of the pump set including PCC foundation, MS bolts with nuts and anti vibration pads including dismantling the pump set and electric motor checking the servicebility, greasing , revarnishing and reassembling including making serviceable the existing pump ,testing and commissioning complete all as specifed and directed. Note:To Make the Pump serviceable deemed to be include in quoted rates by the contractor.

2

-

-

... More
Supply and install Non clog sewage centrifugal pump of discharge 60Cum per hours and 40 metre head horizontal shaft single suction pump with back pullout type design and suitable for solid size upto 65mm impeller made of phosphor bronze, deep groove bell bearings, including electric motor of suitable capacity class F insulation 415V, 50Hz, suction size 150mm and delivery size 150mm bore, complete and mounted on common MS base frame and foundations of the pump set including PCC foundation, MS bolts with nuts and anti vibration pads including following accessories: (a) Cl foot valve fixed with leather washer of suitable size, lift and swing single door IS-4030 marked (b) Pressure gauge diaphragm type upto 50 Kg/Sqcm-01 No (c) Priming arrangement of pump set by providing GI pipe 20mm dia medium grade, gate valve etc from service tank to suction pipe (Not more than 10m away) with all fittings etc complete-01 Job

2

-

-

... More
Fixing only electric driven centrifugal pump set of capable of delivering 13.90 LPS at 45 meter head comprising of horizontal split casing pump CI body with bronze impellers, stainless steel shaft, operating at 1440/1450 RPM coupled through a flexible coupling to a SPDP electric motor 1440/1450 RPM, 3 phase, 415V, 50Hz to match with the capacity of pump complete and mounted on common MS base frame and foundations of the pump set including PCC foundation, MS bolts with nuts and anti vibration pads, Pressure gauge diaphragm type upto 50 Kg/Sqcm-01 No, Cl foot valve fixed with brass flap of suitable size, lift and swing single door IS-4030 ISI marked including nuts, bolts and washers.elc complete all as specified and directed as per OEM. recommendations. including dismantling the pump set and electric motor checking the servicebility, greasing , revarnishing and reassembling including making serviceable the existing pump ,testing and commissioningcomplete all as specifed and directed. Note:To Make the Pump serviceable deemed to be include in quoted rates by the contractor.

2

-

-

... More
Fixing only electric driven centrifugal pump set of capable of delivering 6.95 LPS at 45 meter head comprising of horizontal split casing pump CI body with bronze Impellers, stainless steel shaft, operating at 1440/1450 RPM coupled through a flexible coupling to a SPDP electric motor 1440/1450 RPM, 3 phase, 415V, 50Hz to match with the capacity of pump complete and mounted on common MS base frame and foundations of the pump set including PCC foundation, MS bolts with nuts and anti vibration pads, Pressure gauge diaphragm type- upto 50 Kg/Sqcm 01 No. Ci foot valve fixed with brass flap of suitable size, lift and swing single door IS- 4030 ISI marked including nuts, bolts and washers etc complete all as specified and directed as per OEM recommendations. including dismentling the pump set and electric motor checking the servicebility, greasing , revarnishing and reassembling including making serviceable the existing pump ,testing and commissioning complete all as specifed and directed. Note:To Make the Pump serviceable deemed to be include in quoted rates by the contractor.

2

-

-

... More
S&F, PVC insulated, single core copper conductor Rs cable of size 10 Sqmm, 1100V grade Including cables complete and connection to submersible pump set complete all as specifed and directed.

200

-

-

... More
S&F, PVC Insulated, single core copper conductor cable of size 50 Sqmm, 1100V grade Including cable lugs complete and connection to submersible pump set complete all as specifed and directed.

50

-

-

... More
M&L for Cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in foundations, couping of poles etc including fair finishing the exposed surface even and smooth with out using extra cement and necessary form work complete all as specified and directed

0.5

-

-

... More
SCH 'A' Pt - IX (SEWAGE TREATMENT PLANT)

-

-

-

... More
Design, Supplying, installation, testing & commissioning of Sewage Treatment Plant based on Moving Bed biological Reactor (MBBR) Technology of capacity 250 Cum/day including all civil electro-mechanincal units as mentioned below from following OEMs of STP. (Thermax/Fontus/Simens/Hydro tech Paryavaran Eco Water solution Pvt Ltd / ABB / Siemens /Door Oliver / Dorge Mount/ ION Exchange /Telsa/ NITASHA CONSTRUCTION CHANDIGARH) Note:- Description shall be read in conjuction with the details given here-in-after. P&I and Hydraulic diagram shall be submitted by the contractor as per design giving complete details of civil unites, mechanical units, pumps, valves pipes, etc as per standard format for approval of Accepting officer through GE within on e month of work order to commencement of work. (A) CIVIL UNITS (I) 1 No Bar screen chamber in RCC construction. (ii) 1 Nos Oil & Grease trap chamber in RCC construction (iii) 1 No Equalisation tank in RCC construction (iv) 2 Nos moving bed reactor tanks construct in series in RCC construciton (vi) 1 No chlorine contact tank in RCC construction (vii) 1 No Filter feed tank in RCC construction (viii) 4 Nos sludge drying beds in brick masonry construction complete with media & Sand (ix) 1 No operator room of 12 Sqm area with toilet facility as per specification given in particular specifications. NOTE:- The structural design and drawing shall be got vetted from any IITs/NITs/Government Engineering College before execution of work by the contractor.

2

-

-

... More
Item 9.01 contd.../- (B) MACHANICAL EQUIPMENTS/MACHINARIES & ELECTRICAL COMPONENTS (i) 1 No fine Bar screen as per given specification. (ii) 1 set of UPVC Air grid for Equalisation tank (iii) 2 Nos centrifugal self priming sewage pumps. (iv) 2 Nos Air blower with mtor and its accessories. (v) 2 sets of SS Air grid for MBBR reacotrs as per design (vi) 02 lot of MBBR media as per design requirement (vii)1 Lot of Tube settler media as per design requirement (viii) 2 sets of Hydro-dosing system, each set comprising of tank (HDPE) & Dosing pump. (ix) 2 Nos centrifugal monoblock filter feed pumps (x) 1 No dual media filter (FRP) complete with multiport valve and media as required (xi) 1 No Activated carbon filter (FRP) complete with multiport valve and media as required (xii) 1 Lot of UPVC Air grid for treated water tank (xiii) 1 Lot of inter connecting pipe line network incluidng all n ecessary fittings and valves for efficient functioning of intire shceme all as per design and specification as per approved P&I and Hydraulic diagram approved by Accepting officer (xiv) 1 Lot of instrumentations comprising of 1 No pressure guage for each pump and blower & filters 3 Nos level control switches 1 Nos auto desludge valve & 2 Nos air rotametes. (xv) 1 No electrical panel for electrical unitrs of sewage treatment plant. (xvi) 1 No electrical dabling from STP Panel to various treatment plant drivers with suitable cables

-

-

-

... More
Item 9.01 contd.../- Notes:- 1. The inlet sewage/raw sewage characteristics likely to be as mentioned below:- (a) BOD - 200 to 275 mg /ltr (b) COD - 550 to 600 mg /ltr (c) TSS - 350 to 450 mg /ltr (d) PH - 06-09 (e) Oil & Grease - 20 mg /ltr (f) Coliform - 10^6-10^7MPN/100ml 2. The system shall be capable fo treating the sewage so as to meet the outlet effuent quality as per under mentioned standards:- (a) BOD - 10 mg /ltr (b) COD - 150 mg /ltr (c) TSS - 10 mg /ltr (d) PH - 6.5 - 8.5 (e) Oil & Grease - 10 mg /ltr (f) Coliform - 100 MPN/100ml (g) Residual chlorine 1mg/Ltr 3. The parametes mentioned above except residual chlorine shall be got tested form NABL certified laboratory for approval fo GE before handing over the work to MES

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.