Military Engineer Services Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Electrical and Electronics
Eprocure
Opening Date5 Dec 2024
Closing Date2 Jan 2025
Tender Amount₹ 43,75,000
Costs
EMD
₹ 87,500Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_687113_1Bid Award Id
ViewTender No
GE/SGR/TOK-50 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Provn of wiring from panel to light fitting with five core 4 sqmm copper as required at site with flexible conduit pipe etc.
-
-
-
... More
Provn of single pointed air termination rod and necessary fitment required for protection against lightning protection. Note:- Earthing shall be measured and paid seperately
-
-
-
... More
Testing and commisioning:- (i) Testing & Commissioning of above high mast system complete all as specified and directed.
-
-
-
... More
High mast light foundation shall be designed as per manufacturer's instruction all as specified in Sch 'A'/BOQ Notes here-in-before and to be approved by Accepting Officers. After necessary approval from Accepting Officer, the work of high mast light as specified in BOQ shall be started and executed all as per BOQ specification and as directed by Engineer-in-Charge.
-
-
-
... More
Necessary paid voucher duly verified by Engineer-in-Charge shall be kept on record before making payment. Contractor shall submit guarantee certificates issued by manufacturers to Engineer-in-Charge.
Note:- Rate quoted against this item shall be deemed to included for for all above (i.e 1.01 to 1.07) provisions.
-
-
-
... More
Supply laying &testing Cable XLPE insulated Screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy Duty) With stranded aluminium conductor, 1100 volts grade of size 35 Sqmm 3.5 core complete all as specified and directed.
645
-
-
... More
Supply laying &testing Cable XLPE insulated Screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy Duty) With stranded aluminium conductor, 1100 volts grade of size 16 Sqmm 4 core complete all as specified and directed.
424
-
-
... More
Excavation in trenches in hard/ dence soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and directed.
172
-
-
... More
Returning, filling, including spreeding leveling watering and well ramming in layers not exceeding 25 cm apart complete all as specified and directed.
85
-
-
... More
Removing of surplus excavated soil to distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtrs above the starting point complete all as specified and directed.
86
-
-
... More
M&L for sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete all as specified and directed.
69
-
-
... More
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size 250mm x 150mm x 40mm complete all as specified and directed.
5600
-
-
... More
Supply and laying and fixing in position galvanized iron pipe 50mm bore light grade fixed to pole with mild steel clamps of required size or laid through wall/under floor/under road/in trenches Complete all as Specified and directed.
30
-
-
... More
M&L for earthing complete with galvanised steel earth plate electrode 600X600X6 mm thick, burried directly in ground,earth pit not less than 2.25 meter deep below ground level with top edge of earth plate not less than 1.5 meter below ground level, steel earth plate connected with 25 x 4 mm GI strip by means of bolts, nuts, check nuts and washer of galvanised iron or steel as shown in electrical plate No. 5 connected to earth test point all as described in MES schedule part II including excavation earth work concreate pit with 50 mm thick RCC cover in RCC 1:2:4 type B-I duly reinforced with MS bars 6 mm dia @ 150 C/C both ways and pit chamber in PCC 1:2:4 type B-I with 2 Nos suitable lifting handles of 12 mm MS bar and GI protection pipe of suitable size,and watering pipe 20 mm dia with water funnel test point and extra length up to 7.5 meter connected to Panel board all as specified
15
-
-