Military Engineer Services Tender

... More
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date26 May 2023
Closing Date26 Jun 2023
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling, taking out/removing serviceable and functional,fittings/fixtures/accessories like MCCB/change over switch/switch/Bus bar fuses unit etc. of any description & in any position for re-use from the existing feeder pillar box/panel board complete all as directed.

50

-

-

... More
Fixing only including necessary connection and commissioning of the following fittings /fixtures/accessories in the existing or newly fabricated panel board/feeder pillar box all as specified and directed by Engineer-in-Charge(items taken from item no. 4)

-

-

-

... More
MCCB/change over switch/switch fuses/Bus bar after servicing and cleaning unit etc of any description, and current rating upto 400 Amps

50

-

-

... More
Supply and Fixing any Size/Amp rating of new Aluminium bus bar with colour code insulation of any shape and size including necessary holes/bending/nut bolts/washers/post insulator etc.

200

-

-

... More
Taking out old unserviceable insulator from LT panel boards and supply, fixing & testing epoxy bus bar insulator in bus bar system including nuts, bolts and washers suitable for LT 415 Volts, 50 Hz AC supply for mounting of bus barsin LT panels/feeder pillar boxes complete all as specified and directed.

100

-

-

... More
Supplying, fixing, in existing LT feeder pillar boxes, mild steel sliding door bolt 200 mm size clip & bolt type, stove enameled black, with bright bolt not less than 12 mm dia with and including welding the sliding bolt & staple plate complete all as specified and directed. Note : No welding is permitted.

50

-

-

... More
M&L in replacement of MS Hinge plate in existing feeder piller boxes/ panel boards with necessary auto hinged etc including making necessary adjustment by mechanical work for free and smooth movement of door and locking arrangements complete all as specified and directed by Engineer-in-Charge. Note : (i) No welding is permitted.(ii) Hinge Not less than 1.5 mm thick.(iii) flange size not less than 100mmX 60 mm.

100

-

-

... More
Replacement of existing unserviceable/damaged part / portion of the existing feeder pillar box / panel boards with supplying and fixing new part or portion fabricated out of 2mm thick MS sheet (CRCA sheet) in position including making necessary adjustments and alignments to make the existing feeder pillar box/ panel board body to required shape(s). NOTE : (i). The panel board repaired shall be made totally enclosed, weather proof,wermin proof for installing incoming / outgoing MCCB / Switch fuses/ cable etc complete all as directed (ii) The rates quoted by the contractor are deemed to be with and including necessary cutting, welding, leveling and jointing etc. as directed to match & accommodate with the existing feeder pillar box / panel board .

30

-

-

... More
Preparation of the old decorated existing external and internal steel surfaces of feeder pillar boxes/panels/ boards of any description and in any position including removal of disintegrated & deteriorated paint either by hand scrapping or by blow lamps, applying necessary filler coat and stopping as required and applying two coats of synthetic enameled paint (grey in color) with using spray machine on old prepared surfaces complete all as specified and directed by Engineer-in-Charge.

70

-

-

... More
Surface excavation over the areas around the poles/feeder piller boxes/ sub stations not exceeding 15 cm depth including cleaning the bushes and vegetation and leveling incl removal of surplus soil in hard/ dense soil. Complete all as specified.

150

-

-

... More
Supply, fabrication and fixing for mild steel structure such as cross arms, bracing,supports, clamps and back plate fabricated from structural steel sections including nuts & bolts, washers of any description on LT over head line poles/ street light poles complete all as specified & directed by Engineer -in- Charge.

1

-

-

... More
Disconnecting existing LT over heated or burnt cable terminal at existing panel/board/feeder pillar box etc., cutting out over heated / burnt / unserviceable and portion of cable, stretching / opening cable to suitable required length from available rings etc. and fixing and connecting the cable in position properly by providing suitable new aluminium lugs and suitable GI nuts, bolts & washers sleeves joining kit etc and excavation,refilling deemed to be included in quoted rates all as directed by the Engineer-in-Charge for the following sizes of cables Note : Sleeve, jointing kit will be paid separetely.

-

-

-

... More
25 Sqmm to 95 Sqmm cable of 3.5 Core

250

-

-

... More
120 Sqmm to 185 Sqmm cable of 3.5 core

50

-

-

... More
240 Sqmm to 400 Sqmm cable of 3.5 core

10

-

-

... More
Supply and fix MCCB 4 Pole, 415 V in repair fixed type,100 Amps with breaking capacity 36 KA complete all as specified and directed.

20

-

-

... More
Supply and fix MCCB 4 Pole, 415 V in repair fixed type, 125 Amps with breaking capacity 36 KA complete all as specified and directed.

20

-

-

... More
Supply and fixing of MCCB 4 Pole, 415 V in repair Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specifed and directed.

25

-

-

... More
Supply and fixing of MCCB 4 Pole, 415 V in repair Adjustable type, 200 Amps with breaking capacity 36 KA complete including spreader terminals all as specifed and directed.

25

-

-

... More
Supply and fixing of MCCB 4 Pole, 415 V in repair Adjustable type, 250 Amps with breaking capacity 36 KA including spreader terminals complete all as specifed and directed.

18

-

-

... More
Supply and fixing of MCCB 4 Pole, 415 V in repair Adjustable type, 400 Amps with breaking capacity 36 KA complete including spreader terminals all as specifed and directed.

10

-

-

... More
Supply and fixing of MCCB 4 Pole, 415 V in repair Adjustable type, 630 Amps with breaking capacity 50 KA including spreader terminals complete all as specifed and directed.

2

-

-

... More
M&L Cable joining kit for LT cable for outdoor termination heat shrink type joint complete with joining material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 sqmm to 95 sqmm.

250

-

-

... More
M&L Cable joining kit for LT cable for outdoor termination heat shrink type joint complete with joining material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm.

50

-

-

... More
M&L Cable joining kit for LT cable for outdoor termination heat shrink type joint complete with joining material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 400sqmm

10

-

-

... More
M&L LT Cable insulation protection sleeve Heat shrink type single Core sleeve for LT Cable of size 25 sqmm to 50 sqmm .

200

-

-

... More
M&L LT Cable insulation protection sleeve Heat shrink type single Croe sleeve for LT Cable of size 70 sqmm to 150 sqmm .

200

-

-

... More
M&L LT Cable insulation protection sleeve Heat shrink type single Croe sleeve for LT Cable of size 185 sqmm to 400 sqmm .

100

-

-

... More
M&L Straight through joint Heating kits type for LT cable of size 25 to 50 sqmm, XLPE armoured cable 3.5 core.

10

-

-

... More
M&L Straight through Heating kits type for LT cable of size 70 to 150 sqmm, XLPE armoured cable 3.5 core.

10

-

-

... More
Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade complete with curve stone around the interlocking.

20

-

-

... More
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 32x6 mm (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit , internal surface of concrete shall be given 10mm thick plaster in CM 1:4 and 40 mm thick precast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed by Engineer-in-Charge. NOTE: Earth strip and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth strip/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’

40

-

-

... More
Supplying and fixing earth continuity conductor or main earthing lead 32mm x 6mm, GI strip/earth lead, laid in pipe/fixed on walls or any other position including jointing by tinned copper/brass nuts, bolts and washers in addition to brazing at every joint complete all as specified & directed

50

-

-

... More
Dismantling and taking down existing unserviceable/worn out danger notice plate for LT panel/ LT feeder pillar boxes, supply & fixing for danger notice plate 20x15cm size made out of 1.6 mm thick mild steel sheet, duly painted with vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with including connected accessories complete all as specified and directed.

50

-

-

... More
M&L for shifting of LT panel from one location to another after disconnecting of all LT cable connections,PCC works and refixing the same after repairing complete all as specified and directed.

2

-

-

... More
Supply, laying and testing of cable XLPE insulated, armoured,heavy duty, electric LT UG cable with multi stranded aluminium conductor, 1100 Volts grade including taking out existing cable of following size:-

-

-

-

... More
25 Sqmm 3.5 core.

400

-

-

... More
35 Sqmm 3.5 core.

400

-

-

... More
70 Sqmm 3.5 core.

200

-

-

... More
95 Sqmm 3.5core.

200

-

-

... More
120 Sqmm 3.5core

200

-

-

... More
Excavation in tenches not exceeding 1.5m wide and not exc 1.5m depth and getting out in hard/dense soil complete all as specified and as directed.

350

-

-

... More
Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in soft/loose soil complete all as specified and as directed.

210

-

-

... More
Removing excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed.

140

-

-

... More
M&L for sand filling/cushioning in trenches for cable protection including consolidation complete all as directed.

105.3

-

-

... More
Supplying and laying reinforced precast concrete cable cover, class EHV, type 1 with peak Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and directed

7700

-

-

... More
M&L for PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete all as specified and directed.

5

-

-

... More
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded BT stone aggregate as in bed block for hold fast or coping including necessary form work complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
Disconnecting and remove old LT Panel and replace new panel with supply, installing, testing and commissioning of outdoor LT panel board 415 Volts, 4 wire, 3 phase factory fabricated powder coated, cubical, weather and vermin proof outdoor kiosk type, front opening, floor mounted made out of 3.15 mm thick CRCA sheet of size suitable for mounting the its accessories with electrolyte connection of the equipment/accesories to be fixed, cable glands, lugs, mounted on steel angles supports of suitable size with grouting 4 Nos supports in PCC 1:2:4 type B1 complete with separate compartment for housing with proper arrangement for air circulation and including the following accessories all as specified and directed. (a) Electrolytic aluminium bus bar 600 Amps in distant colour with epoxy supported insulators - 01 Job (04 Nos). (b) MCCB 4 pole,400 Amps, 415 Volts, rupturing capacity 36 KA - 01 Nos for incoming, MCCB 4 pole, 250 Amps, 415 Volts, rupturing capacity 16 KA - 01 Nos for (Outgoing), MCCB 4 pole, 200 Amps, 415 Volts, rupturing capacity 16 KA-02 Nos for outgoing,MCCB 4 pole 160 Amp, 16KA - 01 No for out going. (c) Volt Meter digital type 0 to 500 volts with selector switch - 01 Nos (d) Ammeter digital type 0 to 100 Amps with CTs & selector switch - 01 Nos (e) R,Y & B Phase indication lamp LED type ( Set of three ) - 01 set

2

-

-

... More
Disconnecting and remove old LT Panel and replace new panel with Supply, installing, testing and commissioning of outdoor LT panel board 415 Volts, 4 wire, 3 phase factory fabricated powder coated, cubical, weather and vermin proof outdoor kiosk type, front opening, floor mounted made out of 3.15 mm thick CRCA sheet of size suitable for mounting the its accessories with electrolyte connection of the equipment/accesories to be fixed, cable glands, lugs, mounted on steel angles supports of suitable size with grouting 4 Nos supports in PCC 1:2:4 type B1 complete with separate compartment for housing with proper arrangement for air circulation and including the following accessories all as specified and directed. (a) Electrolytic aluminium bus bar 600 Amps in distant colour with epoxy supported insulators - 01 Job (04 Nos). (b) ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 630 Amps - 01 Nos for incoming, MCCB 4 pole, 200 Amps, 415 Volts, rupturing capacity 16 KA - 02 Nos for (Outgoing),MCCB 4 pole 160 Amp, 16KA - 01 No for out going. (c) Volt Meter digital type 0 to 500 volts with selector switch - 01 Nos (d) Ammeter digital type 0 to 100 Amps with CTs & selector switch - 01 Nos (e) R,Y & B Phase indication lamp LED type ( Set of three ) - 01 set (f) Changeover with capacity of 400 Amp-02 Nos.

1

-

-

... More
Disconnecting & taking out non functional ACB of any description and any make of rating 11KV, 630 Amps to 800 Amps dismantling/opening of the ACB for servicing/over hauling taking out and removing unserviceable/defective parts including cleaning and servicing greasing,oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the ACB after over hauling /servicing and its testing complete all as specified and directed (Note: -The quoted rates of the contractor includes for replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch 'A' as supply only).

2

-

-

... More
Supply only following spare parts for 11 KV, 630 Amps to 800 Amps capacity conforming to the respective cat part given as under : (Note (i) fixing and testing element of following item is deemed to be included under sch 'a' here-in-before(ii) Quantity of under mentioned items is tentative and contractor shall have no claim on account of variation of quantity or non execution of any of the item)

-

-

-

... More
Supply and fixing in replacement of Arc Chutes for LT air circuit breakers. Make as per existing complete all as specified and directed

1

-

-

... More
Supply and fixing in replacement of MS arcing horn(Set of 1 No. Fixed 1No. Moving )for LT ACB. Make as per existing complete all as specified and directed

2

-

-

... More
Supply and fixing in replacement of Vertical Terminal Adapter for AH/AHA Fixed type ACB of 630/800 amps ACB. Make as per existing complete all as specified and directed

2

-

-

... More
Supply and fixing in replacement of Auxiliary Isolating contacts Blocks Assembly (set of one contact block on ACB side & two blocks on cradele side ) for 630/800 Amp ACB. Make as per existing complete all as specified and directed

2

-

-

... More
Supply and fixing in replacement of Single Phase Resin Cast CTS for " AA/AHA" ACB for Thermal release for LT air circuit breakers of 630/800 Amp.

2

-

-

... More
Supply and fixing in replacement of Auxiliary Isolating Contact Assembly (Set of onecontact block on ACB side & two blocks on cradle side)for LT air circuit breakers.

2

-

-

... More
Supply and fixing in replacement of Auxiliary Isolating Contact Assembly (Set of one contact block on ACB side & four blocks on cradle side)for LT air circuit breakers.

2

-

-

... More
Supply and fixing in replacement of Main Isolating Contacts (Jaw Contacts) for LT air circuit breakers. Make as per existing (Qty required per pole=2)complete all as specified and directed

2

-

-

... More
Supply and fixing in replacement of Lower terminals with fitting plates.

2

-

-

... More
Supply and fixing in replacement of Main Fixed Contacts (Upper Terminals) for LT air circuit breakers. Make as per existing (Qty required per pole=1)complete all as specified and directed

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.