Military Engineer Services Tender

... More
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date17 Feb 2025
Closing Date8 Mar 2025
Tender Amount₹ 35,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for point wiring using approved color coding as per IS (Red, Black and Green for singlle phase circuits), with multi-stranded copper conductor stranded copper conductor, 1.5 sqmm nominal cross sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, IS-694 marked with valid CML no. in and including stove enamleed steel conduit and conduit accessoriees on wall/roof/floor etc. ISI marked with valid CML No. (IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), with mild steel/pressed steel sunken box (IS 5133) (with earth dolly) duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primerr interrnally and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulators etc, including PVC insulated multistranded copper conductor 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the following:

-

-

-

... More
(a) One light point/fan point controlled by one switch

320

-

-

... More
(b) One socket outlet 5 Amps controlled by one switch on the same board.

60

-

-

... More
(c) One socket outlet 5 Amps controlled by one switch on independent board.

65

-

-

... More
(d) One bell / buzzer controlled by one bell push.

16

-

-

... More
(e) One light point controlled by two way switch.

7

-

-

... More
All as per item No. 3.00 here-in-before but with 2.5 Sqmm multi stranded copper conductor cable for one 15 Amps socket outlet controlled by one switch on independent board and 1.5 Sqmm PVC insulated multistranded copper conductor cable as continuous earth wire.

80

-

-

... More
M&L for point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade ISI marked drawn into and including surface PVC Casing Caping medium grade not less than 19/20 mm ( as per IS14927 ) with all fitting and fixing accessories including sunk in cast iron / pressed steel terminal boxes(IS 5133) (duly painted with two coats of anti corrosive paint out side and two coats of aluminium paint inside ) with 2.8 mm thick hylum brand laminated white bakelite sheet cover for mounting switches, sockets, fans regulators etc and 1.5 sq mm multi stranded copper conductor cable as continuous earth wire complete all as specified and directed for the following:-

-

-

-

... More
(a) One light point/fan point controlled by one switch

94

-

-

... More
(b) One socket outlet 5 Amps controlled by one switch on the same board.

40

-

-

... More
(c) One socket outlet 5 Amps controlled by one switch on independent board.

50

-

-

... More
(d) One bell / buzzer controlled by one bell push.

5

-

-

... More
(e) One light point controlled by two way switch.

5

-

-

... More
All as per item No. 5.00 here-in-before but with 2.5 Sqmm multi stranded copper conductor cable for one 15 Amps socket outlet controlled by one switch on independent board and 1.5 Sqmm PVC insulated multi stranded copper conductor cable as continuous earth wire.

42

-

-

... More
M&L for sub main wiring with two single core 4.0 Sqmm multi stranded copper conductor, FRLS PVC insulated, unsheathed cable including rigid non metallic PVC conduit, medium grade, ISI marked, 20 mm dia for sub main wiring including 4.0 sqmm FRLS PVC insulated and unsheathed stranded copper conductor as earth wire in surface/recess and making good to the disturbed surfaces to match the existing surfaces complete including taking down existing unserviceable sub main of any type and size complete all as specified and directed. Note:- Two runs of 4.0 Sqmm copper conductor cable, one run of 4.0 Sqmm copper conductor and one run of PVC conduit will be measured as one unit.

130

-

-

... More
M&L for sub main wiring with two single core 6.0 Sqmm multi stranded copper conductor, FRLS PVC insulated, unsheathed cable including rigid non metallic PVC conduit medium grade, ISI marked, 20 mm dia for sub main wiring including 6.0 Sqmm FRLS PVC insulated and unsheathed stranded copper conductor as earth wire in surface/recess and making good to the disturbed surfaces to match the existing surfaces complete including taking down existing unserviceable sub main of any type and size complete all as specified and directed. Note:- Two runs of 6.0 Sqmm copper conductor cable, one run of 6.0 Sq mm copper conductor and one run of PVC conduit will be measured as one unit.

80

-

-

... More
M&L for switch piano flush type pole one way 5 Amps, 240 V complete all as specified and directed.

700

-

-

... More
M&L for socket outlet 3 pin 5 Amps, 240 V flush type complete all as specified and directed.

250

-

-

... More
M&L for piano flush type 5 Amps single pole two way complete all as specified and directed.

30

-

-

... More
M&L for switch piano flush type pole one way 15 Amps, 240 V complete all as specified and directed.

120

-

-

... More
M&L for socket outlet flush type multi purpose 2 in 1, 3 pin 5 and 15 Amp, 230 Volts complete all as specified and directed.

110

-

-

... More
M&L for ceiling rose surface bakelight two to three terminal complete all as specified and directed.

260

-

-

... More
M&L for Lamp Holder, insulated body, with back plate for batten fitting complete all as specified and directed.

110

-

-

... More
S&F in repairs switch socket combination outlet flush type multi purpose 2 in 1, 3 pin 5 and 15 Amp, 230 Volts complete all as specified and directed.

140

-

-

... More
S&F in repairs of Ding Dong Bell AC, 240 Volts single pole complete all as specified and directed.

25

-

-

... More
M&L for electronic step type Fan Regulator/Mini switch type dimmer 120/280 Watt capacity including connecting up complete all as specified and directed.

92

-

-

... More
S&F of 09 Watt LED bulb, in white colour with maximum Lumen output (850 lm) and colour temp 3000 K, complete all as specified and directed.

340

-

-

... More
S&F of 09 Watt LED bulb with inbuilt rechargeable battery and control circuit, battery backup upto 4 hrs in white colour with maximum Lumen output (850 lm) and colour temp 3000 K complete all as specified and directed.

114

-

-

... More
S&F of 1x20 Watt LED tube light fitting polycarbonated housing prewired with all accessories and including LED tube rod 20 Watt 4 feet long inlcuding connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable 3 core of size 0.50 Sqmm complete all as specified and directed.

550

-

-

... More
S&F of 1x20 Watt LED inverter batten tube light fitting with inbuilt battery and control circuit, battery backup upto 4 hrs, prewired with all accessories 4 feet long including connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable 3 core of size 0.50 Sqmm complete all as specified and directed.

70

-

-

... More
S&F of LED light fitting mirror type polycarbonated housing with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.

17

-

-

... More
S&F in repairs existing make Modular switch1 way 6A, 240 Volts 1 module complete all as specified and directed.

212

-

-

... More
S&F in repairs existing make Modular switch 1 way 16A, 240 Volts 1 module complete all as specified and directed.

90

-

-

... More
S&F in repairs existing make Modular Bell push 10A 1 module complete all as specified and directed.

22

-

-

... More
S&F in repairs existing make Modular Socket, 6A - 5 pin combined 2 module complete all as specified and directed.

120

-

-

... More
S&F in repairs existing make Modular Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed.

50

-

-

... More
S&F in repairs existing make Modular Fan step regulator 120W, 240 Volts 1/2 module complete all as specified and directed.

40

-

-

... More
S&F in repairs 3 Pin, Plug Top 5/6 Amp, 220 volt complete all as specified and directed.

40

-

-

... More
S&F in repairs 3 Pin, Plug Top 15/16 Amp, 220 volt complete all as specified and directed.

44

-

-

... More
Supply only for replacement of unserviceable wire of size 1.5 sqmm ISI marked single core FRLSH insulated multistranded copper conductor for working voltage 1100 volts complete all as specified and directed.

6

-

-

... More
All as per item No. 32.00 here-in-before but of size 2.5 Sqmm.

4

-

-

... More
All as per item No. 32.00 here-in-before but of size 4.00 Sqmm.

4

-

-

... More
S&F in replacement of PVC insulated multistranded aluminium conductor twin core of size 6 Sqmm, 1100 Volts grade heavy duty service cable, served with inner sheathing of PVC tape and over all PVC sheathed in service connections complete all as specified and directed.

180

-

-

... More
S&F in repairs building security light fitting LED 35 Watt energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP-66 roadway luminaire with high power LED as light source with toughened glass and impact resistance PF IK-08 and GI pipe 40 mm dia, light grade, for mounting bracket bent to shape 1.50 RM and fixing arrangement with two Nos of MS clamps set, nut bolts, washers of suitable size and fixing on wall/pole complete including taking down unserviceable fitting complete all as specified and directed.

25

-

-

... More
S&F of LED luminaire 600mm x 600mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.

14

-

-

... More
S&F in repairs recess mounted adjustable for LED 15W Watt downlights made of extruded aluminium housing and high power LED light source with Driver clear diffuser with separate electronic driver with complete accessories complete all as specified and directed.

24

-

-

... More
S&F in repairs surface LED 15 Watt downlighter with white powder coated aluminium housing with integrated electronic driver with complete accessories all as specified and directed.

12

-

-

... More
S&F in repairs of HEXA 10 W-IP-66 Bulk Head luminaries, with lamp holders, including one 1X 10W LED etc. complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50 HZ including taking down unserviceable fitting complete all as specified and directed.

7

-

-

... More
S&F of post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.

8

-

-

... More
S&F in repairs sheet metal enclosure MCB DB 4 way tripple pole and neutral 415 Volts complete including taking down unserviceable fitting complete all as specified and directed.

21

-

-

... More
S&F in repairs sheet metal enclosures for SPN DB's 240 volts, factory made double door, flush type, IP-42 protection and all as per IS-8623, made from sheet metal 8 way 200 amps rated bus bar to be fixed with wall all accessories complete including taking down unserviceable fitting complete all as specified and as directed.

40

-

-

... More
S&F in repairs sheet metal enclosure single pole and neutral with a two pin and earth plug and socket with and including one single pole MCB 20 Amps 240 volts complete including taking down unserviceable fitting complete all as specified and as directed.

20

-

-

... More
S&F in repairs MCB, single pole, 10 kA breaking capacity having 'C' characteristics as per IS-8828 with air circulating channels, 240 volts 6 to 32 Amps complete including taking down unserviceable fitting complete all as specified and as directed.

200

-

-

... More
S&F in repairs MCB SPN 240 volts 16 to 40 Amps, 10 kA breaking capacity having 'C' characteristics as per IS-8828 with air circulating channels complete including taking down unserviceable fitting complete all as specified and as directed.

100

-

-

... More
S&F in repairs MCB TPN 63 Amp 440 Volts, 10 kA breaking capacity having 'C' characteristics as per IS-8828 with air circulating channels including taking down unserviceable fitting complete all as specified and as directed.

21

-

-

... More
S&F in repairs MCB double pole 240 Volts 40 Amps, 10 kA breaking capacity having 'C' characteristics as per IS-8828 with air circulating channels complete all as specified and directed.

30

-

-

... More
M&L for measurment of earth resistivity test with earth tester and T&P required at site by deploying sufficient manpower by the contractor and made entry in register and put up to conerned JE and Engr-in-Charge complete all as specified and directed.

160

-

-

... More
M&L for earthing complete with glavanised steel earth plate elactrode 600x600x6.0 mm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below ground levels) with top edge of the plate not less than 1.5 mtr deep below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of nut, bolt, check nut and washer of galvanised iron or of steel, earth lead protected by 15 mm dia GI pipe light grade watering pipe 20 mm dia GI light grade GI wire meshed funnel alternate layer of charcoal and salt PCC chamber, reassed for and including RCC cover including all necessary excavation and earth work, earth wire connected to main switch board, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR Pt-I 1991 print and as directed.

17

-

-

... More
Taking down carefully AC ceiling fan 1200mm/1400mm sweep, exhaust fan 300mm to 450mm sweep and wall moundted bracket fan 300/450mm sweep from their position complete for servicing such as removing dust and dirt from fan motor, washing blades with detergent powder including greasing to bearing, checking & replacing worn out screws with spring washers, rubber befit washers of fan blades, fan motor body, spilt pin/screw for fan down rod/check nuts as required for different makes of ceiling/exhaust fans to put fans fans to smooth and satisfactory working and refixing ceiling fan/exhaust fan after executing necessary servicing to their position connecting to electric system with suitable size of cable and testing, complete all as specified and directed. Note : Rates quoted by contractor shall deemed to be inclusive all minor items and no extra payment shall be admissible except for the items which are to be replaced which shall be measured and paid separately under respective item of Schedule 'A'.

370

-

-

... More
M&L for preparation of old painted surfaces of ceiling fan, exhaust fan & wall mounting fan by scrubbing, cleaning with sand paper/wire brush etc making good surfaces and painting by applying synthetic enamelled first quality paint using spray gun in situ including filling cavities with filler and marking Srl No SM No / MES No with black paint complete all as specified and directed.

80

-

-

... More
M&L for rewinding of AC ceiling fan, 230 volts, 50 Hz, 1200mm/1400mm sweep of any make with appropriate gauge super enamelled copper winding wire including allied insulation material such as air drying insulation varnish, cotton tapes, lathered film paper, spacers, sleeves etc re-assembling at its position after repair, testing and commissioning complete all as specified and directed.

280

-

-

... More
M&L for rewinding of exhaust fan/wall mounted fan, 230 volts, 50 Hz, 300/450mm sweep of any make with appropriate gauge super enamelled copper winding wire including allied insulation material such as air drying insulation varnish, cotton tapes, lathered film paper, spacers, sleeves etc re-assembling at its position after repair, testing and commissioning, complete all as specified and directed.

35

-

-

... More
S&F of ball bearing 6202/6203 in replacement suitable for AC ceiling fan of 1200/1400mm sweep/ exhaust fan/ air circulation fan of any make to replace the unserviceable bearing including greasing as required complete all as specified and directed.

65

-

-

... More
S&F in replacement capacitor, 4/5 mfd 230 volts, AC, 50 Hz, complete all as specified and directed.

60

-

-

... More
S&F in replacement capacitor, 2.5 mfd 230 volts, AC, 50 Hz, complete all as specified and directed.

370

-

-

... More
S&F in repairs split pin with hook, rubber and nut bolt of suitable for ceiling fan/exhaust fan of any sweep and make complete all as specified and directed.

90

-

-

... More
S&F in repairs shaft of approved quality for ceiling fan/exhaust fan any make, type and size complete all as specified and directed.

35

-

-

... More
S&F in repairs self lubricating bush of gun metal as per ceiling fan/exhaust fan complete all as directed.

45

-

-

... More
S&F in replacement fan canopy complete all as specified and directed.

35

-

-

... More
S&F in repairs hanging rod 1ft/2 ft complete all as specified and directed.

80

-

-

... More
S&F in repairs fan blade 1200/1400 mm complete all as specified and directed.

79

-

-

... More
S&F in repairs PVC insulated, unsheathed three core copper flexible cable of size 1.5 Sqmm including connection complete all as specified and directed.

3

-

-

... More
Taking down carefully Geyser of capacity 25/35 ltrs from its position for repair/servicing such as removal of dust, checking, replacing worn out parts, rubber etc, re-assembling at its position after repair, testing & commissioning & connecting to electric system with suitable size cable complete all as specified and directed. Note : Rates quoted by contractor shall deemed to be inclusive all minor items and nothing shall be admissible except for the items which are to be replaced which shall be measured and paid separately under respective item of Schedule 'A'.

55

-

-

... More
S&F of galvanized iron water tubing, medium grade, 15mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors including taking down complete all as specified and directed.

42

-

-

... More
S&F of galvanized iron water tubing, medium grade, 20mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors including taking down complete all as specified and directed.

22

-

-

... More
S&F of geyser tank of capacity 25 ltrs complete all as specified and directed.

4

-

-

... More
S&F of geyser tank of capacity 35 ltrs complete all as specified and directed.

4

-

-

... More
S&F of heating element for geyser, 1500 watt, ISI marked, round type, complete all as specified and directed.

17

-

-

... More
S&F of heating element for geyser, 2000 watt, ISI marked, round type, complete all as specified and directed.

14

-

-

... More
S&F of heating element for geyser, 1500 watt, ISI marked, triangle type, complete all as specified and directed.

17

-

-

... More
S&F of heating element for geyser, 2000 watt, ISI marked, triangle type, complete all as specified and directed.

14

-

-

... More
S&F of thermostat suitable for geyser of any capacity complete all as specified and directed.

50

-

-

... More
S&F of angle stop valves, 15mm bore, fancy type, chromium plated with long shank and cup (concealed type), cast copper alloy, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., fixed in repairs, complete all as specified and directed.

7

-

-

... More
S&F of bib tap, 15mm bore, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule, fixed in repairs, complete all as specified and directed.

7

-

-

... More
S&F of stainless steel connection 15mm dia, 900mm long with brass CP nuts and washers at both ends for hot water & cold water, fixed in repairs, complete all as specified and directed.

20

-

-

... More
Taking down/out deep freezer/refrigerator transporting to contractor's workshop for carrying out repairs, taking out assembly, welding/brazing after detecting the leakage, as mentioned in respective items of schedule including transporting back after repair, re-fixing at site, making it functional after replacement of worn out nuts, bolts, washer etc. including re-connecting electrical connection and testing complete all as specified and directed. Note :- Cost of material and labour for providing new items shall be measured and paid separately.

3

-

-

... More
Taking down/out water cooler of 40/80 ltrs and 60/120 ltr capacity transporting to approved work shop for carrying out repairs, taking out assembly, welding/brazing after detecting the leakage, as mentioned in respective items of schedule including transporting back after repair, refixing at site, making it functional after replacement of worn out nuts, bolts, washer etc. including re-connecting electrical connection testing complete all as specified and directed. Note :- Cost of material and labour for providing new items shall be measured and paid separately.

3

-

-

... More
M&L for preparation of old painted surfaces of deep freezer/ refrigerator/ water cooler of capacity upto 320 litres by scrubbing, cleaning with sand paper/wire brush etc making good surfaces and repainting by applying two coats of synthetic enamelled first quality paint using spray gun over over one coat of red oxide zinc chrome primer and marking Srl No SM No/ MES No with black paint complete all as specified and directed.

4

-

-

... More
S&F in replacement of following unserviceable items of Deep freezer/refrigerator of 300/310/320 litres as required at site including testing of the same complete all as specified and directed:-

-

-

-

... More
(a) MS condensing coil with fixing arrangement for 300/310/320 litres capacity complete with gas charging.

2

-

-

... More
(b) Over load protector.

3

-

-

... More
(c ) Thermostat switch (Auto defrost).

3

-

-

... More
(d) Temp control knob with defrost push button.

3

-

-

... More
(e) Electrical lamp pin/threaded type 15 watt, 240 volts AC supply.

3

-

-

... More
(f) PVC ice tray of superior quality.

3

-

-

... More
(g) Relay as per existing.

3

-

-

... More
Supply, fixing and testing new compressor, single phase, 240 Volts, AC supply in replacement including cost of rubber bushes, bolts, nuts washers, copper tubing capillary tube, dryer filter terminal cover, thimbles, electrical wiring oil and gas charging (R-134 or as recommended by manufacture) and testing complete for the following including transportion etc :-

-

-

-

... More
(a) Compressor of Deepfreezer/Refrigerator of cap 300/310 Ltr.

2

-

-

... More
(b) Compressor of Water Cooler of capacaity 300/310 Litres.

2

-

-

... More
S&F in replacement of following unserviceable items by opening of water cooler of 40/80 or 60/120 Ltrs capacity frost free for following replacement of unserviceable accessories and refixing, connecting and testing complete all as specified and directed:-

-

-

-

... More
(a) Copper Condensing coil complete with fixing arrangement.

2

-

-

... More
(b) Fan motor 1/2 HP, 240 volts, single phase AC supply.

2

-

-

... More
(c ) Aluminium Blade for fan motor complete blower.

2

-

-

... More
(d) Thermostat.

2

-

-

... More
(e) Relay as per existing make.

3

-

-

... More
(f) Over load protector.

2

-

-

... More
(g) Float Valve brass 15 MM bore.

3

-

-

... More
(h) Push type tap 15mm bore, brass chromium plated

3

-

-

... More
Supply and filling/charging of following water collers/Deepfreezer with refrigerant R-22A/R-134 or as recommended by manufacturer including flushing out oil, vacuming, top up oil, brazing, leak detection, testing etc for following cooling appliances including replacement of capillary tube and dryer filter complete all as specified and directed:- Note:-. The type of refrigerant gas shall be charged as per manufacturer recommendation.

-

-

-

... More
(a) Water cooler 60/120 litres capacity.

2

-

-

... More
(b) Deep Freezer/Refrigerator of capacity up to 320 Litres.

2

-

-

... More
S&F in replacement of water lifting pump (water immersed) for desert cooler with model-HM-09, 240 volts, 50 Hz, 40 watts, 1.5 metre max head and output 800 LPH complete all as specified and directed.

16

-

-

... More
S&F in replacement of khas pads/wood wool pad of required size for desert cooler of any make complete all as specified and directed.

30

-

-

... More
S&F in repairs of blower motor, 230 volts, single phase, 50 Hz, suitable for desert cooler/ Exhaust fan size 350/450 mm as per site requirement including kit consists of mounting clamps, blades, speed contol switch, nut, bolts and washers complete all as specified and directed.

7

-

-

... More
S&F in replacement of exhaust fan louver of any size complete all as specified and directed.

8

-

-

... More
S&F in repairs voltage stabilizer of capacity 5 KVA installing and testing complete all as specified and directed.

3

-

-

... More
Taking down defective Split/Window AC of 1.5 Ton capacity from any height and any places for repair and refixing at its original place after replacement of defective/wornout parts & making serviceable complete all as specified and directed. Note:- Worn out spares parts required for making AC serviceable/functional shall be measured and paid separately under appropriate item as 'Supply only'.

10

-

-

... More
Supply only fan motor for 1.5 ton AC complete all as specified and directed.

3

-

-

... More
Supply only AC compressor for 1.5 ton AC complete all as specified and directed.

3

-

-

... More
Supply and charging gas 22 R for 1.5 ton AC complete all as specified and directed.

9

-

-

... More
Supply only AC copper pipe of size 8mm and 15 mm for 1.5 ton AC complete all as specified and directed.

40

-

-

... More
Supply only 45 Mfd capacitor for 1.5 ton AC complete all as specified and directed.

8

-

-

... More
Supply only contactor, single phase, 30 Amp for 1.5 ton AC complete all as specified and directed.

7

-

-

... More
Supply only fan belt for 1.5 Ton AC complete all as specified and directed.

7

-

-

... More
Supply only printed circuit board of split AC/Window AC 1.5 ton complete all as specified and directed.

4

-

-

... More
Supply only over load protector complete all as specified and directed.

4

-

-

... More
Maintenance for operationaly fit of RO based aqua guard installed for water cooler, with replacement of candle, Replacement of Membrane, Replacement of Pre filter candle, Replacement of Diaphragm Pump 24 volt DC and open flow minimum 2.0 Ltr/min checking of AC supply circuitary of aqua guard and made functional, replacement of step down transformer 230 volt to 12/24 volts, as per sample, incl servicig of RO complete all as directed at site.

2

-

-

... More
S&F of the following items/spares in replacement for solar heaters of various capacities as mentioned complete all as specified and directed:-

-

-

-

... More
(a) Heating element of capacity upto 2 KW (Electric rod) having rubber washer of size 1 ¼” or 1 ½”

3

-

-

... More
(b) Heating element of capacity upto 1.5 KW (Electric rod) having rubber washer of size 1 ¼” or 1 ½”

3

-

-

... More
(c) Glycol (Anti freezing solution) for filling in copper tubes

40

-

-

... More
(d) Dead flange with nut, bolts and washers

3

-

-

... More
(e) Float valve assembly 15mm dia

3

-

-

... More
(f) Thermostat suitable for solar heater

3

-

-

... More
(g) Hot water steel tank non stick 2mm thick with ceramic lining of capacity 500 Ltrs each including making necessary connections

2

-

-

... More
S&F of solar bollard light 3 Watt with IP65 rating with inbuilt solar panel, LED light and lithium Battery of 4Ah capacity, battery backup upto 8 Hrs with charge controller complete all as specified and directed.

6

-

-

... More
S&F of solar gate light 2 watt with solar panel output 3.7 W, battery capacity 2.5 Ah, battery backup upto 8 hrs, IP65 rating with inbuilt solar panel, LED light and lithium battery with charge controller complete all as specified and directed.

4

-

-

... More
S&F in replacement of unserviceable Polycarbonate doom globe garden light with LED Bulb 9W to be fitted in pipe dia 50 mm of existing make complete all as specified and directed.

20

-

-

... More
M&L for flame proof point wiring on wall surface wiring on ceiling with necessary fixing arrangements for one light point controlled by one switch with stranded PVC, FRLS insulated and unsheathed copper multistranded conductor of size 2.5 sqmm, 1100 volts grade drawn in and including 14 gauge ERW rigid steel conduit (metallic) not less than 20 mm dia with all MS conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc., including PVC-FRLS insulated and unsheathed copper stranded conductor of size 2.5 sqmm, 1100 volts grade for continuous earthing making good the distrubed surface either by means of plaster of paris/ putti or distemper/ colour wash with same existing colour surfaces including taking down existing unserviceable light point wiring, fitting and fixtures complete all as specified and directed. Note:- (i) Junction box flame proof shall be measured and paid under relavent item. (ii) Earth wire shall be of green colour (iii) Colour code should be maintined

13

-

-

... More
All as per item No. 105.00 here-in-before but for fan point wiring

1

-

-

... More
All as per item No. 105.00 here-in-before but two light point controlled by one flame proof switch.

2

-

-

... More
All as per item No. 105.00 here-in-before but power point wiring using 4 Sqmm copper conductor cable and 4.0 Sqmm as earth wire.

2

-

-

... More
M&L for flame proof sub main wiring with two single core 4 sqmm multi stranded copper conductor, FRLS PVC insulated, unsheathed cable, including ERW rigid metallic steel conduit medium grade, ISI marked, 19/20 mm dia for sub main wiring including 4.0 sqmm FRLS PVC insulated and unsheathed stranded copper conductor as earth wire in surface/ recess with all MS conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc and making good to the disturbed surfaces to match the existing surfaces complete including taking down existing unserviceable sub main wiring complete all as specified and directed. Note:- (i) Three runs of 4 Sqmm copper conductor cable, and one run of ERW rigid metallic conduit will be measured as one unit.

50

-

-

... More
S&F of flame proof junction box with spigotted cover in LM-6, three way/terminal block 4 way strip type cable entry, 20 mm dia hole aluminium constructed, internal dimension 80 mm dia and 40 mm depth, duly approved by CMRI Dhanbad complete including taking down existing unserviceable junction boxes of any type and size all as specified and directed.

4

-

-

... More
S&F of flame proof bend any radius of CI/MS with brass nickle threaded of size 20mm complete including taking down existing unserviceable flame proof bend of any type and size including taking out old unsv complete all as specified and directed.

4

-

-

... More
S&F of flame proof union brass of size 20 mm complete including taking down existing unserviceable flame proof union brass of any type and size including taking out old unsv complete all as specified and directed.

2

-

-

... More
S&F of flame proof plug brass of size 20 mm complete including taking down existing unserviceable flame proof plug brass of any type and size incl taking out old unsv complete all as specified and directed.

3

-

-

... More
S&F of flame proof flexible metalic hose conduit of size 3/4" dia and 300 mm long suitable for explosive atmosphere with explosive dust proof complete including taking down existing unserviceable metallic hose conduit of any type and size complete all as specified and directed.

6

-

-

... More
S&F of flame proof rotary switch in LM6, 10/16 amps, single pole, 250 volts and enclosed cast aluminium body with threaded cover with switch operated by a sigle pole knob with double entries suitable for 20 mm dia ERW threaded steel conduit duly approved by CMRI dhanbad and as manufacturers intructions including taking down existing unserviceable rotary switches of any type and size complete all as specified and directed.

8

-

-

... More
S&F of flame proof switch socket outlet with plug combination in LM-6, 16 Amps, 250 Volts, two pin and earth with no spare plug complete all as per manufacturer's instruction complete including taking down existing unserviceable switch sockets of any type and size complete all as specified and directed.

4

-

-

... More
S&F of flame proof LED light fitting 2X20 Watts, epoxy finish LM6 aluminium housing with heat resistant tubular glass cover held in two aluminium cups, with built-in control gear accessories, prewired including complete including taking down existing unserviceable light fittings complete all as specified and directed.

7

-

-

... More
S&F of flame proof bulk head flat type glass fittings, 30 Watts LED ceiling/wall mounted complete including taking down existing unserviceable bulk head fittings of any type and size with point wiring complete all as specified and directed.

6

-

-

... More
S&F flame proof well glass light fittings, 30 Watts LED ceiling/wall mounted complete including taking down existing unserviceable bulk head fittings of any type and size all as specified and directed.

6

-

-

... More
M&L for rewinding of burnt out copper winding of flame proof ceiling fans of any make, size 1200 mm/1400mm sweep, rewinding with super enamelled copper wire of approved quality of existing gauge and size including necessary insulation with leathoroid sheet varnishing of winding of coil, packing, proper insulation, gasket etc including cleaning the rotor & the stator, overhauling, lubricating with fresh graese, etc and re-hanging the same and testing and commissioning, including taking out old unsv complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
All as per item No. 120.00 here-in-before but flame proof exhaust fan of any size.

1

-

-

... More
S&F flame proof ceiling fan regulator etc. including taking down existing unserviceable ceiling fan regulator of any type and size all as specified and directed.

1

-

-

... More
S&F fix flame proof cast iron enclosure distribution board 415 volts, 4 way, TPN with ELCB and MCB suitable for explosive atmosphere with explosive including necessary panel board for required connection from busbar to different outgoing and including making good to the disturbed surfaces of walls, floors etc.complete all as approved by CMRI Dhanbad with following incoming and outgoing controls including taking down existing unserviceable MCBs of any type and size all as specified and directed:- (i) Incoming:- ELCB 4 pole, 415 volts, 63 Amps - 01 No. (ii) Outgoing:- MCB 16 amps - 8 Nos.

2

-

-

... More
S&F flame proof cast iron enclosure Main Switch Rotary Type 63 Amp 4 Pole, 415 Volt with all fixing arrangement and making good to the disturbed surfaces of walls, floors etc complete including taking down existing unserviceable main switches of any type and size all as specified and directed as approvedd by CMRI Dhanbad.

2

-

-

... More
M&L for Air termination single pointed aluminium rod 12mm dia, 300mm long fixed on GI Pipe complete including taking down unserviceable air termination point all as specified & directed.

40

-

-

... More
M&L GI Pipe 40mm dia, medium grade, for air termination rod fixing, including fitting supported with GI Flange 40 mm bore, incl taking down unserviceable GI pipe all as specified & directed. Note: GI Flange will be measured and paid seperately under relevent item

20

-

-

... More
M&L for GI reducer of size 40x12 mm dia medium grade with threaded type suitable to fit air termination complete all as directed by Engr-in-Charge.

10

-

-

... More
M&L for providing cement concrete on roof of type B1 1:2:4 using 20 mm graded stone aggregate for foundation of GI pipe fo lightning protection /as per existing at site all specified and directed.

1

-

-

... More
Taking down and refixing the old removed Aluminium/GI strip any size on roof/wall incl replacement of 'T' type insulators complete all as directed by Engr-in-Charge. Note: 'T' type porcelain insulators shall be measured and paid separately under relvent item

300

-

-

... More
S&F 'T' type heavy duty insulators made of DMC material suitable for supporting 25 x 3 mm / 32 x 6 mm strip on roof or as down conductor on wall/surface including all fixing accessories required complete all as specified and directed.

100

-

-

... More
S&F aluminium strip 25X3.15mm with saddler and drilled holes, nut bolt washers and fixing srewed on wall/ roof etc for roof conductor down conductors on roof/wall run on porcelain insulators between suitable distance including taking down unserviceable aluminum strip all as specified & directed. Note :- Necessary nut, bolt and washer for fixing alongwith drilled holes are included in coated rate.

200

-

-

... More
M&L for GI strip 32x6mm burried in ground/fixing on wall/floors complete with drilled hole alongwith necessary nut, bolt and whasher including taking down unsereviceable G I strip all as specified and directed. Note :- Necessary nut, bolt and washer for fixing alongwith drilled holes are included in coated rate.

100

-

-

... More
Taking out old unserviceable tube rod and supply and fix in replacement of LED tube rod 20 watt capacity single side connection (for flame proof fitting)complete all as directed by Engr-in-Charge

20

-

-

... More
All as per item No 133.00 here-in-before but double side connection.

20

-

-

... More
Taking out old unserviceable static handle discharge copper tube any size, supply and fix static handle discharge copper tube of size 25 mm dia and 600 mm long complete all as directed by Engr-in-Charge

4

-

-

... More
M&L for test point terminal block made of gunmetal or phasphorus bronze of size 75x75x25mm drilled and srewed including 03 Nos 8mm dia 25mm long hexagonal head screwed including taking down unserviceable terminal block all as specified and directed.

10

-

-

... More
Repair of earthing pit cover such as damage RCC cover, water funnel, PCC chamber including testing of earth resistivity test with earth tester and T&P required at site by deploying sufficient manpower by the contractor and made entry in register and put up to conerned JE and Engr-in-Charge complete all as specified and directed.

29

-

-

... More
Deduct amount of Rs. 115,078.00 for Schedule of Credit (Calculation will be done ofline)

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.