Military Engineer Services Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Electrical and Electronics
Electrical Works
Eprocure
Opening Date9 Feb 2024
Closing DateCancelled
Tender Amount₹ 20,00,000
Costs
EMD
₹ 40,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_641565_1Tender No
GE(MCTE)/MHOW/48(T) OF 2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Removing surplus excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.50m above the starting point complete all as specified and directed.
145.3
-
-
M&L for filling approved fine river sand in trenches as cable cushion to the full width of excavated trench , under and over cable complete all as specified and as directed.
Note : Punned thickness of sand shall be measured
105.3
-
-
M&L for bricks slightly over burnt (kiln burnt) , modular bricks , best quality, locally available , laid flat, dry, laid in trenches along the length of cable transvarsally with width equal to length of brick for cable protection all as specified and directed.
20000
-
-
Taking down damaged PCC/steel pole/strut of any size all as specified and as directed.
2
-
-
S&F steel tubular electric pole, swaged type, welded, type 410 SP-31 (9 m long) erected to truly vertical position complete with CI base plate, finial taper plug, bolts, nuts & screws complete all as specified and as directed including painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block/ concrete with two coats of aluminium paint over a coat of red oxide zinc chrome primer including preparation of surfaces and making 30 cm wide five alternate strips with black and yellow paint above GL/plinth with synthetic enamel paint including marking pole number with black paint complete all as directed.
Note : Earth work and PCC work shall be measured & paid for separately under respective item of this scheduale.
2
-
-
S&F GI tubing, light grade, 80 mm bore pipe laid in trenches/duct or in road crossing or fixed to wall/poles for protection of cable complete all as specified and as directed.
18
-
-
All as per item No.09 above but 50mm bore.
12
-
-
All as per item No.09 above but 40mm bore.
12
-
-
Taking out old unserviceable underground cable armoured with aluminium conductor of any size from trenches, walls or ducts complete all as specified and as directed.
2400
-
-
Supply & Laying XLPE insulated, armoured, electric cable with aluminium conductor, 1100 volts grade, laid in trenches, fixed on poles / walls or passing through pipes including provision of necessary lugs and glands & making necessary connection complete all as specified and as directed, of the following sizes:-
-
-
-
10 Sqmm 2 core.
200
-
-
16 sqmm 4 core
200
-
-
25 Sqmm 3.5 core
250
-
-
35 Sqmm 3.5 core
200
-
-
50 Sqmm 3.5 core
300
-
-
70 Sqmm 3.5 core
250
-
-
95 Sqmm 3.5 core
300
-
-
120 Sqmm 3.5 core
250
-
-
150 Sqmm 3.5 core
200
-
-
185 Sqmm 3.5 core
150
-
-
240 Sqmm 3.5 core
100
-
-
S&F in replacement of aluminium lugs including testing complete of the following sizes :-
-
-
-
6 mm dia
10
-
-
10 mm dia
10
-
-
16 mm dia
20
-
-
25 mm dia
20
-
-
35 mm dia
20
-
-
50 mm dia
20
-
-
70 mm dia
20
-
-
95 mm dia
20
-
-
120 mm dia
20
-
-
150 mm dia
20
-
-
185 mm dia
20
-
-
240 mm dia
20
-
-
300 mm dia
20
-
-
400 mm dia
20
-
-
M&L for PCC 1:4:8, type D2 ( using 40 mm graded crushed stone aggregate) as in base of the pole, complete all as specified and as directed.
0.11
-
-
M&L for PCC 1:3:6, type C2 (using 40 mm graded crushed stone aggregate) as in foundation for poles, complete all as specified and as directed.
1.02
-
-
M&L for PCC 1:2:4, type B1 ( using 20 mm graded crushed stone aggregate) as in base,coping of the pole, complete all as specified and as directed.
0.16
-
-
S&F MCCB, TPN, fixed type, thermomagnetic release, 415 Volts, including taking out old unserviceable MCCB of any type and make complete of the following sizes :-
-
-
-
40 Amps 16 kA
2
-
-
63 Amps 16 kA
2
-
-
100 Amps 16 kA
3
-
-
125 Amps 26 kA
3
-
-
150 Amps 26 kA
2
-
-
200 Amps 26 kA
3
-
-
250 Amps 26 kA
2
-
-
320 Amps 36 kA
2
-
-
400 Amps 36 kA
2
-
-
Taking down unserviceable /burnt out MCB from existing LT Panel board duly disconnected all electrical connection & Supply and fixing new MCB SP 6-32 Amps , incl making necessary cable connection complete all as specified and directed.
6
-
-
Taking down unserviceable /burnt out MCB from existing LT Panel board duly disconnected all electrical connection & Supply and fixing MCB 63 Amps TPN , incl necessary cable connection complete all as specified and directed.
8
-
-
Supply & laying or fixing 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner shething of PVC tape overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtrs apart incl 4 sqmm twin core flat/circular cable.
180
-
-
All as per item No.55 but 6 Sqmm 2 core
180
-
-
All as per item No.55 but 10 Sqmm 2 core
180
-
-
S&F in repalacement of insulator shackle type, porcelain, vitreous, white or brown or green for LT, 1100 volts grade including galvanised mild steel strip of section 30 mm x 5 mm and insulator bolts 14 mm dia with washers & nuts, 100 mm height & 115 mm (max) dia complete all as specified & as directed.
6
-
-
S&F in repalacement of insulator pin type, porcelain, vitreous, white or brown insulator including one galvanised mild steel spindle, two galvanised iron washers & one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade complete all as specified & as directed.
6
-
-
M&L for providing under ground boring using mechanical pneumatic drilling equipment for passing electric cables through by providing GI pipe of 50mm dia bore light grade, under the existing bituminous/WBM road/PCC hard standings, depth range not more than 1.5m deep and making good the distrubed surfaces to match with its existing specifications complete all as specified and as directed. Note : Any damage to the existing cables/water pipes/structures shall be made good by the contractor at his own expense and nothing extra shall be paid on this account.
12
-
-
S&F in replacement Solar LED light fitting 24 watt with high efficiency All-In-One Solar street light Mono Crystel, Lithium Ferro Phosphate battery with in-built BMS technology,MPPT Solar Charge controller and aluminium extruded body with PIR motion sensor automatically control the dimming and brightness of light, battery capacity 30AH,IP65, temp 5700K complete all as directed.
Make : Havells Cat Part No LHSTAKU7CBAF024/Bajaj/Eveready
2
-
-
Cutting the existing bituminiuos road for passing of UG cable in road crossing and making good the disturbed surface of road to its original specification complete all as directed.
12
-
-
Supply and fixing cable route indicator, made out of MS sheet of size 200 mm x 150 mm x 3 mm thick, spot welded with angle iron of size 40mm x 40mm x 5 mm thick, 750 mm long embedded in PCC (1:2:4) type B-2( using 40mm graded crushed stone aggregate) block 30cm x 30cm x 40cm in ground including one coat of synthetic enamel black paint over one coat of red oxide zinc chrome primer and writing with white paint showing size of cable HT / LT complete all as specified & as directed.
10
-
-
Cutting, trimming and prunning of trees/tree branches of any girth upto 2.5m all around existing LT over head lines / sourrounding street light and flood light fitting including cleaning the area beneath the LT overhead lines and removing the debris from the site and depositing where directed complete all as specified.
100
-
-
Cleaning and upkeeping the area including uprooting of shrubs/grass and removing creepers from fencing or poles / posts and brooming the complete area of sub station around panels,transformers, four pole structures etc upto 3 feet from fencing or pole externally , all around complete and maintaining the same during currency of contract period, removing the debris to a distance not exc 50m and depositing where directed complete all as specified. Note : The payment shall be made one time and nothing extra shall be admissible to upkeep the area during currency of the contract period. The cost of brooms, showels, pick axe etc shall deemed to be included in the rate quoted by tenderer.
1000
-
-
Taking down old unserviceable capacitor of any capacity and replace with new Duca Power XD capacitor, withstand Harmonic overloads upto 4 Amp Max current, low losses 0.2 watt/KVAR, three phase, temperature range (-)25 degree centigrate to 70 degree centigrate of the following rating :-
-
-
-
a) 5 KVAR
4
-
-
b) 10 KVAR
5
-
-
c) 25 KVAR
8
-
-
Taking down old unserviceable power contactor of any capacity and replace with new contactor three phase of the following sizes:-
-
-
-
a) Contactor for capacitor heavy duty 3 pole with AC coil 1NO 0NC 25 Amps.
4
-
-
b) Contactor for capacitor heavy duty 3 pole with AC coil 1NO 1NC 40 Amps.
3
-
-
c) Contactor for capacitor heavy duty 3 pole with AC coil 1NO 1NC 95 Amps.
3
-
-
Taking down old unserviceable Harmonic Block Reactors for Detuned System for any capacity and replace with new Harmonic Block Reactors for Detuned System for 50 KVAR capacitor, three phase copper wound with an iron core and air gap,highest quality material , high class insulation,filtering factor 7% all as directed.
6
-
-
Sppply & Laying, armoured, electric copper cable of size 25 sqmm 1 core with multi stranded copper conductor, 1100 volts grade, laid in trenches, fixed on poles / walls or passing through pipes & making necessary connection complete all as specified and directed.
100
-
-
S&F in replacement of copper lugs including testing complete of following sizes :-
-
-
-
(a) 10 mm dia
24
-
-
(b) 25 mm dia
30
-
-
Taking down old UNSV fuse assembly any capacity and replaced with new DIN fuse base assembly fixed type suitable for 100 Amps all as directed.
Make : Havells cat part No IHUC000100
5
-
-
Taking down old UNSV fuse any capacity and replaced with new DIN type HRC fuse 415 volts suitable for 100 Amps all as directed Make : Havells cat part No IHHCD11100
5
-
-
M&L of earthing complete with GI steel earth plate electrode 60cm x 60cmx6.0mm thick barried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 mtrs below level ground, connected to GI strip 32x6mm by means of nuts, bolts checks nuts and washers made of GI earth wire protected by GI pipe 40mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) pre-cast RCC (1:2:4) type-B-1, cover slab 30cmx30cmx10cm with one lifting handle made out of 8mm dia MS bar funnel wire mesh, 20mm bore GI or steel pipe medium grade for watering, charcoal or coke and salt in alternate layers, including necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 3 of MES schedule Part-I and testing after completion.
6
-
-
Supply and errecting LT Panel outdoor type mounted and fixed with PCC foundation, made out of MS sheet factory assembled & factory fabricated out of 3.15 mm thick sheet steel with suitable size MS angle frame duly spray painted with two coats of gray synthetic enamel paint over one coat of red oxide zinc chrome primer after preparatiion of surface, with required civil works & with and including 4 Nos aluminium bus bars 600 Amps with suitable size porcelain insulators & wiring with copper cable of suitable size, connecting including indicating lamp LED type for each phase, incl inbuilt industrial type locking arrangement, front operated and back openable incl necessry arrangement for fixing with suitable clamps, nuts & bolts etc. The panel pre wired with PVC insulated copper conductor danger notice board, feeders marked, and testing & commissioning, size of panel 2'x2'x1' complete all as directed.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements