Military Engineer Services Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date10 Dec 2024
Closing Date2 Jan 2025
Tender Amount₹ 35,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S&F in replace recess mounted spot light with reflector 2 watts 65 mm dia with white powder coated polycarbonate housing and pressure die-cast heat sink having high efficiency with heavy duty driver.

10

-

-

... More
S&F in replace LED bldg security light fitting 30 watts made up of pressure die cast aluminium housing with acylic cover as diffuser with IP-65 and IK-07 protection, THD 10% , lumen output ≥ 110 lumen per watt complete all as specified and directed.

30

-

-

... More
S&F in replacing post Top lantern LED type 25 watts suitable for mounting in GI post 32 mm to 50 mm size (ballest and SPDs inside lantern base) with suitable bolts/ screws complete incl necessary welding ,threading with tap and dies all as specified and directed at site

20

-

-

... More
S&F in replace GI mounting pipes of building security light fittings of size 32 mm to 40 mm size upto 1.2 mtr length bend into sizes incl mounting clamps , saddles, uit bolt and washers all as specicified and directed.

80

-

-

... More
M&L for flexible wire twisted 23/0076 of size 1.5 sq mm for replacing from ceiling rose to ligth fiitings/ceiling fan/exhaust fans complete all as specified and directed.

400

-

-

... More
S&F in replace 3 core copper flexible cable 2.5 sqmm complete all as specified and directed.

500

-

-

... More
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 06 sq. mm 2 core fixed on wall/ceiling by saddling with suitable screws , laying in ground all as specified and directed.

200

-

-

... More
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 core fixed on wall/ceiling by saddling with suitable screws , laying in ground all as specified and directed.

400

-

-

... More
S&F in replacement of PVC junction box IP - 66 Thermoplastic PC- GFS Polycarbonate weatherproof Junction Box with Degree of protection against mechanical load IK09 (10 Joule) with plain walls for cable entries to be drilled individually. The plain side walls on the four sides can be drilled and customized for cable entries from any direction. The Junction box Internally embedded polyurethane material Gaskit. Lid fasteners shall not have screws but shall be with quarter turn locking knobs . The junction box shall fulfill the following standards Weatherproof : UV resistant due to solar radiation, Rainwater proof, temperature resistant. Salt water proof & shall be suitable for off-shore applications and pole fixed to Junction Box clamps made out of MS flat iron 25 X 4 mm ,MS hexagonal bolts, nuts and washer for arrangement to pole /surface complete all as specified and directed by Engr in charge. IEC 60670-22 : Particular requirements for connecting boxes and enclosures. IEC 60695 – 2 – 11 : Flame – retardant & Self-extinguishing. Glow Wire tested at minimum 960 deg C. IEC 60529 : IP 66 degree of protection. colour: black, RAL 9011 Degree of protection against mechanical load IK09 (10 Joule) Technical details Cat.no.- KF 2500 Hensel , with MCB 6A SP ,4nos 16sq.mm terminal Block Dimension in mm- 155 x 210 x 92 mm

37

-

-

... More
M&L for repair/replacing of PCC of post top lantern/FPB/bollards incl necessary form work ,cement mortar work 1:4 for finishing complete incl two coat of distumbering as per approved colour after applying cement primer all as specified and directed

2.4

-

-

... More
M&L for fixing GI pipe 65 mm dia medium grade of suitable length as directed at site and making standing pole for post top lantern in existing RCC pillar with necessary breaking of RCC pillar top ,cutting Existing GI Pipe 50 mm size , welding with 65 mm GI pipe including fixing FRP looping box at bottom of pillar ,casting of PCC , making good disturbed surface with PCC, cementing, Plastering incl painting all as specified and directed . Note: PCC ,GI pipe 65mm, Necessary excavation and FRP loopng box will be measured and paid seperrately as per relevent item in schedule.

4

-

-

... More
M&L for replacing GI pipe 63 to 65 mm dia medium grade for fixing post top lantern all as specified and directed .

6

-

-

... More
M&L for replacing GI tubings light grade for cable protection 50 mm size complete all as specified and directed.

62

-

-

... More
M&L for surface mounted LED fitting 36 watts, 2 ft x 2 ft fittings suitable for RCC ceiling, lumen out put ≥ 110 lumen/watt ,THD 10% environmental friendly, new generation,aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source,incl inbuilt drivers incl making good of disturbed surfaces during installation all as specified and directed.

20

-

-

... More
M&L for LED ceiling fitting 33 to 36 watts, 2 ft x 2 ft fittings suitable for aluminium grid ceiling, lumen out put ≥ 122 lumen/ watt,THD 10% environmental friendly, new generation, aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source,incl inbuilt drivers suitable for Grid ceiling complete with atration of aluminium frame work wherever necessary during installation all as specified and directed.

25

-

-

... More
Description same as per Sl. item no. 18.00 here in above but of 42 to 48 watts.

20

-

-

... More
Supply and fix in repairs Post Top Lantern fully aluminium cast body finished with polyurethane paint(with prior treatment) with acrylic window cover .Total length 635 mm and Max breadth 323mm, heritage look ,spigot entry 78mm as per IS 10322 complete incl altration in mounting by welding/threading/placing addl GI socket to place lantern truely vertical in position all as specified and as directed. Model No PTL-003 of

20

-

-

... More
Supply and fix in repairs Bollard 20 watts fully aluminium cast body finished with polyurethane paint(with prior treatment) of length 647 mm and circular base dimeter of 139mm and max dimeter of leg of bollard 76 mm surmounted with fully cast aluminium body finished with polyurethane paint with acrylic window. Total length of bollard fittings : 1181mm. Model No MBL-D-002.

50

-

-

... More
Supply and fix in repaire Architectural designed aluminium cast extra heavy duty pole mounted post top lantern incl heavy duty leg and boarder deigner base with broader plate 422MMx422MM finished with olyurethane paint ( with all prior treatement ) Diameter of pole leg is approx 76mm. Outer dia for spigot entry 60 mm 03 Nos T shaped bolts with nuts and washers provided for concrete foundation Including 01 No Post top lantern Model No PTL003 and 02 Nos post top lantern model PTL03 along with squre junction made out of aluminium finished with max projection breadth of 880 mm suitable for three Nos post top lantern complete all as specifed and as directed. Mode No of Pole: MCPL 02 and model no of squre junction is CDPB04 of Mepro electricals/ equivalenet in Crompton/ Bajaj

4

-

-

... More
M&L for bollard 09 watts made of extruded aluminium housing for land scaping with better light quality and enhance architectural design IP 65 protection, fixing in PCC foundation with suitable nut bolt and washers complete all as speciied and as directed. Model No BGBOLL6059WLED of Bajaj or equivalent make in Crompton/ Bajaj

64

-

-

... More
M&L for LED Bulk head fitings of wattage 6 to 13 watts designed for modern homes available with premium quality diffuser for glarefree light and easy to install snapfit installer complete including taking down of old CFL/bulb bulk head fitting, making good of surfaces all as specified and directed.

80

-

-

... More
M&L for decorative wall mounted luminare indoor application made out of stainless steel body with acrylic cover with LED bulb 9W , 230V, 50 Hz complete all as specified and directed .

60

-

-

... More
M&L for decorative wall light made out of Die cast aluminium for exteriar wall glazing application 12 W , 230V, 50 Hz complete all as specified and directed .

60

-

-

... More
M&L for replacing Bay luminare Eco round highbay in PDC housing suitable for industrial application . The luminare has efficeincy of 110 lm/W complete all as specified and directed. Model No TIP-320-80-57-SL-NSG of Crompton make or equivalent in Bajaj/Havells/Philips

12

-

-

... More
Supply and fixing strip light of 25 watts for COB lighting with IP 20 protection LED strip should be included LED driver for every 5 meter role and warrenty should be 2 years from the date of purchase and color temparature should be warm white incl fixing along along POP/wall pannel edges in prestigeous building all as specified and directed.

10

-

-

... More
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of , all as shown in electrical plate No. 3 connected to earthing test point and complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C-1 (using 20 mm grade crushed stone aggregate) earth chamber, RCC 1:1.5:3, type A-1 cover slab, 40 mm thick reinforced with 6 mm dia TMT bar @ 150 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 15 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.

1

-

-

... More
Supplying, laying, fixing, jointing and testing LT under ground XLPE insulated, galvanised teel strip or wire armoured heavy duty electric cable with alumimium conductor,with multi stranded 1100 volts grade, cross sectional area 16 Sqmm x 4 Core, ISI-7098 marked, with electric connection lugs, laid in trenches/under floor or fixed naked with walls / on poles/ in ducts / in GI pipes etc. and including taking down complete all as specified and directed. Note - Excavation, earth work, sand cushioning, protection bricks/tiles/ block, clamps, nuts , bolts, washers and pipe shall be measured and paid separately.

200

-

-

... More
Description all as per Sl. Item No. 30.00 above but 10 sqmm x 4 Core

300

-

-

... More
Supplying, laying, fixing, jointing and testing LT services cable FRLSH heavy duty electric cable with copper conductor, 1100 volts grade, cross sectional area 10 sqmm 2 core, ISI marked, with electric connection lugs, fixed naked with walls / on poles/ on high mast / in GI pipes etc. and including taking down complete all as specified and directed.

150

-

-

... More
Supplying, laying, fixing, jointing and testing LT services cable FRLSH heavy duty electric cable with Copper conductor, 1100 volts grade, cross sectional area 1.5 sqmm 2 core, ISI marked, with electric connection lugs, fixed naked with walls / on poles/ on high mast / in GI pipes etc. and including taking down complete all as specified and directed.

500

-

-

... More
Supply & Fixing MCB SP 6 to 32 Amps current rating 'C' series 10 KA breaking capacity complete all as specified and directed

60

-

-

... More
Supply & Fixing MCB SPN 32 Amps current rating 'C' series 10 KA breaking capacity complete all as specified and directed

60

-

-

... More
S&F MCB TPN, 32 Amps breaking capacity 10 kA, C curve complete with connection testing and commissioning including spreader link & taking down complete all as specified and directed.

15

-

-

... More
S&F MCB TPN, 63 Amps breaking capacity 10 kA, C curve complete with connection testing and commissioning including spreader link & taking down complete all as specified and directed.

10

-

-

... More
Supplying, laying, fixing, jointing and testing LT services cable heavy duty electric cable with Aluminium conductor, 1100 volts grade, cross sectional area 10 sqmm 2 core, ISI marked, with electric connection lugs, fixed naked with walls / on poles/ on high mast / in GI pipes etc. and including taking down complete all as specified and directed.

400

-

-

... More
Supplying, laying, fixing, jointing and testing LT services cable heavy duty electric cable with Aluminium conductor, 1100 volts grade, cross sectional area 6 sqmm 2 core, ISI marked, with electric connection lugs, fixed naked with walls / on poles/ on high mast / in GI pipes etc. and including taking down complete all as specified and directed.

200

-

-

... More
Supply and laying in replacement GI pipe 'light grade' 40 mm in trenches, under floors, roads, along poles for protection of cables with all necessary fittings and sealing ends complete all as specified and directed.

60

-

-

... More
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for laying of cables, pipes & poles etc. and getting out all excavated material in any type of soil complete all as specified and directed.

148

-

-

... More
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.

68.5

-

-

... More
Removing of excavated surplus soil to a distance not exc 50 m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.

79.5

-

-

... More
Material and labour for locally available Fine river sand cushioning for under ground cable in trenches 8 cm before laying and 15 cm after laying of cable and punned thickness of sand shall be measured and paid for 18 cm only after punned/consolidated thickness complete all as specified and directed. Note - Punned thickness shall only be measured and paid.

63.5

-

-

... More
Supply and laying unreinforced PCC Cable protection cover, class LV, type-1 flat with size 250 x 150 x 40 mm laid flat width wise complete all as specified and directed.

5600

-

-

... More
M&L Safety Zone High Itensity Water proof Reflective Tape for security light steel tubular pole/Swan Pole upto 09 mtrs length of Pole providing 03 Number alternate strip of 50 cm wide with Orange,Green and white Conspicuity tape highly reflective tape above embeded level and writing pole no. with black round circle 02 inch wide letter on round circle with white colour complete all as specified and directed Note Complete one pole one job

300

-

-

... More
Supply, Installation, Testing and Commissioning in replacement of LED Dimmable Sensor Based Street light Fitting with a nominal system 16200 lumen output of lumens, minimum system efficacy of 175 lm/W and total power consumption not exceeding 120 W . The smart light function of sensor works following points. (a) initial level of light is 100 % brightness when no motion detected. (b) Light level dimmed to 30%-50% level when motion detected (c) Light level increased to 100% for a hold time ranging from 3 minutes to 30 minutes maximum. (d) After hold time completion and no motion detection light level will be decreased to set dimming value :30 % or 50% . The luminaire shall have a rated system lifetime of 50,000 burning hours at L70B50. The luminaire should have a color temperature of 5700 - 6500 K and CRI70. The luminaire shall meet IP66 or IK09 rating with THD10% and PF 0.95. The luminaire housing should made of pressure die cast aluminium and the integrated luminaire optics shall have a high efficiency polycarbonate UV stabilized cover with integated Lens to ensure Asymmetrical batwing light distribution . The fitting should have an internal SPD upto 10 KV, over voltage protection & other safety test as per IS 15885 Part 2 /Sec 13. The luminaire should have a NABL approved LM79 report. LM80 report from the LED manufacture is a must along with photo biological report. Fitting should include nut bolt and SS screws for suitably fixing on the existing steel tubular/Swan pole complete all as specified and directed by Engr -in- Charge.

5

-

-

... More
Supply, Installation, Testing and Commissioning in replacement of LED Street light Fitting with a nominal system 5300 lumen output of lumens, minimum system efficacy of 120 lm/W and total power consumption not exceeding 90 W (including driver). The luminaire shall have a rated system lifetime of 50,000 burning hours at L70B50. The luminaire should have a color temperature of 5700 - 6500K and CRI80. The luminaire shall meet IP66/IK07 or IK08 rating with THD10% and PF 0.95. The luminaire housing should made of pressure die cast aluminium and the integrated luminaire optics shall have a high efficiency diffuser with more than 85% transmittance. The fitting should have an internal SPD of minimum 4 kV. The driver should have phase to phase protection for 8 hours. The luminaire should have a NABL approved LM79 report. LM80 report from the LED manufacture is a must along with photo biological report. Luminaire and the driver shall be BIS certified separately and shall posses separate "R" numbers. Fitting should include nut bolt and SS screws for suitably fixing on the exiting steel tubular pole complete all as specified and directed.

20

-

-

... More
Supply, Installation, Testing and Commissioning in replacement of LED Street light Fitting with a nominal system 5300 lumen output of lumens, minimum system efficacy of 120 lm/W and total power consumption not exceeding 120 W (including driver). The luminaire shall have a rated system lifetime of 50,000 burning hours at L70B50. The luminaire should have a color temperature of 5700 - 6500K and CRI80. The luminaire shall meet IP66/IK07 or IK08 rating with THD10% and PF 0.95. The luminaire housing should made of pressure die cast aluminium and the integrated luminaire optics shall have a high efficiency diffuser with more than 85% transmittance. The fitting should have an internal SPD of minimum 4 kV. The driver should have phase to phase protection for 8 hours. The luminaire should have a NABL approved LM79 report. LM80 report from the LED manufacture is a must along with photo biological report. Luminaire and the driver shall be BIS certified separately and shall posses separate "R" numbers. Fitting should include nut bolt and SS screws for suitably fixing on the exiting steel tubular pole complete all as specified and directed.

15

-

-

... More
Supply, Installation, Testing and Commissioning in replacement of LED Flood Light Fitting with a nominal system 14400 lumen output of lumens, minimum system efficacy of 120 lm/W and the total power consumption should not exceed 120 W (including driver). The luminaire shall have a rated system lifetime of 50,000 burning hours at L70 B50. The luminaire should have a color temperature of 5 - 6500K and CRI80. The luminaire shall meet IP66 / IK07 rating with THD10% and PF 0.95. The luminaire housing should made of pressure die cast aluminium and the integrated luminaire optics shall have a high efficiency diffuser with more than 85% transmittance. The fitting should have an internal SPD of minimum 4 kV. The luminaire should have a NABL approved LM79 report. LM80 report from the LED manufacture is a must along with photo biological report. Luminaire and the driver shall be BIS certified separately and shall posses separate "R" numbers. Fitting should include nut bolt and SS screws for suitably fixing on the exiting steel tubular pole complete all as specified and directed.

15

-

-

... More
Supply, Installation, Testing and Commissioning in replacement of LED Flood Light Fitting with a nominal system 18100 -24000 lumen output of lumens, minimum system efficacy of 120 lm/W and the total power consumption should not exceed 200 W (including driver). The luminaire shall have a rated system lifetime of 50,000 burning hours at L70 B50. The luminaire should have a color temperature of 5700K - 6500K and CRI80. The luminaire shall meet IP66 / IK07 rating with THD10% and PF 0.95. The luminaire housing should made of pressure die cast aluminium and the integrated luminaire optics shall have a high efficiency diffuser with more than 85% transmittance. The fitting should have an internal SPD of minimum 4 kV. The luminaire should have a NABL approved LM79 report. LM80 report from the LED manufacture is a must along with photo biological report. Luminaire and the driver shall be BIS certified separately and shall posses separate "R" numbers. Fitting should include nut bolt and SS screws for suitably fixing on the exiting steel tubular pole complete all as specified and directed.

10

-

-

... More
Disconnecting and taking down street / security light fitting of any size / capacity / make from the pole / bldg for repair / replacment of unservisable spare parts etc., testing, cleaning the fitting internally and externally and replacement of unserviceable wiring not more than 0.3 Mtrs with 1.5 sqmm PVC insulate copper wire, checking and repairing of loose connections, replacement of wire connectors, nuts, bolts, screws and fixing the light fitting in original position on wall / pole / santry post / top of building including necessary electrical connection complete all as specified and directed . Note:- Driver/ SPD shall be measured and paid separately.

500

-

-

... More
Supply, fixing, testing and commissioning in replacement SPD/Driver for LED Street light / flood light fitting with suitable surge capacity complete all as specified and directed .

100

-

-

... More
S&F in replacement of PVC junction box IP - 66 Thermoplastic PC- GFS Polycarbonate weatherproof Junction Box with Degree of protection against mechanical load IK09 (10 Joule) with plain walls for cable entries to be drilled individually. The plain side walls on the four sides can be drilled and customized for cable entries from any direction. The Junction box Internally embedded polyurethane material Gaskit. Lid fasteners shall not have screws but shall be with quarter turn locking knobs . The junction box shall fulfill the following standards Weatherproof : UV resistant due to solar radiation, Rainwater proof, temperature resistant. Salt water proof & shall be suitable for off-shore applications and pole fixed to Junction Box clamps made out of MS flat iron 25 X 4 mm ,MS hexagonal bolts, nuts and washer for arrangement to pole /surface complete all as specified and directed by Engr in charge. IEC 60670-22 : Particular requirements for connecting boxes and enclosures. IEC 60695 – 2 – 11 : Flame – retardant & Self-extinguishing. Glow Wire tested at minimum 960 deg C. IEC 60529 : IP 66 degree of protection. colour: black, RAL 9011 Degree of protection against mechanical load IK09 (10 Joule) Technical details Cat.no.- KF 2500 Hensel , with MCB 6A SP ,4nos 16sq.mm terminal Block Dimension in mm- 205 x 255 x 112 mm

10

-

-

... More
Trimming / lopping of tree branches touching LT/HT OH lines not exceeding 30 cm girth, shrub, vegetation, bushwwod and saplings at least upto 2 mtr from outer edge of ACSR including removing of braches of trees etc. to a distance exceeding 100 mtr and not exceeding 150 mtr complete all as specified and directed. Note :- (i) Linear length centre to centre of the poles shall only be measured. (ii) Shutdown wherever required shall be taken from Engr-in-Charge.

650

-

-

... More
M & L in replacement for Rigid non-metallic PVC FRLS conduit heavy duty of size 20mm external dia , exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc to be fixed along the pole and including taking down complete all as specified and directed .

500

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.