Military Engineer Services Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date3 Sep 2024
Closing Date1 Oct 2024
Tender Amount₹ 9,75,100
Costs
EMD
₹ 19,500Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_658265_2Tender No
8478/KH/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://mes.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering
43
-
-
PCC (1:3:6) type E-2 using 40mm graded stone aggregate as in foundation & mass concrete
3
-
-
RCC Nominal mix M-25 (Design mix) type B1 using 20mm graded stone aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete.
10
-
-
RCC Nominal mix M-25 (Design mix) type B1 using 20mm graded stone aggregate in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses
16
-
-
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
44
-
-
Use and waste of Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to Batter
105
-
-
TMT bars 10mm dia and over dia including all cutting bending binding cranking placing & binding with MS wire (annealed) not less than 0.90mm dia complete
3280
-
-
M&L for rendering on fair faces of brick work or concrete surface of wall 10mm thick in CM 1:6 and to be finished even and smooth without using extra cement complete all as specified and directed
100
-
-
M&L for applying two coats of cement base paint and one coat primer , over a coat of white cement on new wall surface including preparation of surface.
100
-
-
Removing excavated material n exc. 500m and depositing where directed at a level n exc. 1.5m above the starting point
96
-
-
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for foundation, etc for shafts, walls exc 10sqm on plan and getting out any type of soil complete
40
-
-
PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation & mass concrete
4
-
-
M&L 75mm thick PCC type C-2, (1:3:6) using 40mm graded stone aggregate as in plinth protection finished even and fair incl expansion joint at every 3m interval and every corner complete all as specified and directed.
25
-
-
M&L Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed andsealed with sealing compound, Grade ‘A’
3
-
-
TMT bars 5mm dia and over upto and incl 10mm dia in stirrups, spacers and binders.
175
-
-
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions
30
-
-
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
8
-
-
RCC Nominal mix M-25 (Design mix) type B1 using 20mm graded stone aggregate in Columns, pillars, piers, posts and struts.
2.5
-
-
RCC Nominal mix M-25 (Design mix) type B1 using 20mm graded stone aggregate in beams, cantilevers, bressummers, lintels over 1.5m span
2
-
-
M&L for Fly ash brick birck work with well burnt, old size sub class'B' bricks of compressive strength not less than 35 Kg/sqcm, straight or curved on plan exc 6 metre mean radius built in cement mortar (1:6) complete all as specified and directed.
15
-
-
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate in copings, kerbs, and the like all as directed incl necessary form work
0.5
-
-
M&L for rendering 15mm thick on brick work or concrete surface in CM 1:6 finished fair& even surface complete
80
-
-
M&L for rendering 15mm thick on brick work or concrete surface in CM 1:4 finished fair& even surface complete
80
-
-
M&L 25 mm thick PCC type B-1, (1:2:4) using 20mm graded stone aggregate finishing cement concrete surface even and rough complete all as specified and directed.
40
-
-
S&F Coloured Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed in CM(1:6) complete all as specified and directed.
40
-
-
diito all as above in skirting except over 10mm thick bedding layer in CM (1:4)
4
-
-
S&F Rolled mild steel sections as in main & cross beams, hip & jack rafters; purlins where connected to common rafters & running rails & guides for sliding doors; fixed with angle cleats or other connecting plates GDE Fe410-W(Gde- E-250) quality B.
450
-
-
S&F pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding and in ridge to wall, fixed with self tapping screws as specified
40
-
-
M&L suspended false ceiling system using Chicago metallic (E-grid) exposed suspended system, grid size 600x600mm compressing of GI powder coated main runner of dimension 39mmx24mm x 0.8mm thick (Thickness comprising of GI/0.4mm+PPPCGS/0.3mm & weight of runner 1.35 Kg for 3600mm length), cross Tee of dimension 29mm x 24mm x 0.8mm thick (Thickness comprising of GI/0.4mm+PPPCGS/0.3mm & weight of Tee 0.195Kg for 600mm length) and wall angle of dimension 22.2mm x 22.2mm x 0.65mm thick (Thickness comprising of GI/0.35mm + PPPCGS/0.30mm & weight of angle 0.700 Kg for 3050mm length) with and including 8 mm thick HPSC (High Pressure Steam Cured) pre-primed, self embossed, textured designer board, water, termite & fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 4mm dia GI bar hangers fixed with steel dash through fasteners from purlins with butterfly clips (wt 0.007 Kg/clip), hold down clips (wt - 0.0035 Kg/clip), with provn of light fixture complete all as per manufacturer instructions and as directed. (Make : Armstrong/Everest).
40
-
-
Applying two coats of cement base paint, white or tinted on new wall surface including preparation of surface.
80
-
-
Preparation of new decorated surfaces of walls and applying two coat of distempering with acrylic washable distemper oil emulsion white or tinted complete all as specified and directed.
80
-
-
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, & steel peg stay, complete with glazing bars, dovetailed or welded
6.5
-
-
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, & steel peg stay, complete without glazing bars, dovetailed or welded
6.5
-
-
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire & average width of aperture 1.40mm with stainless steel wire staples
6.18
-
-
M&L for rough cast wired glass n exc 0.5sqm , 6.4mm thick and glazing with oil putty in square all as specified and directed.
6.18
-
-
S & F in repair WPC Door Frame 95x45 mm including all fitting making good after complete as directed as speicifed Make : Rajshree or equivelent
5
-
-
S&F factory made plain framed ,35 mm Panelled shutter (two Panel) with lock rail of 9 mm B.W.P. commercial ply or 12 mm veneered patticle boar with commercial veneering on both face , the size of rail and stile as per IS: 1003 (Part 1) kiln seasoned and chemically pressure treated
2
-
-
M & L two coats of synthetic enamel painting over a coat of pink primer including preparation of new wooden surfacesof any description over 10 cm width or girth.
5
-
-
S&F Butt hinges medium weight cold rolled mild steel 100mm long complete.
3
-
-
S&F Aluminium anodised barrel tower bolts of extruded section 200mm long complete,
2
-
-
S&F Aluminium handles cast type anodised of 200mm complete.
2
-
-
S & F in repair Door spring ordinary rat tail rod pattern springs including roller and roller plate complete of mild steel 300 mm long complete.
1
-
-
S&F in repair aluminium alloy anodized sliding door bolt with hasp, staples (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts or extruded sections or cast aluminium alloy length of bolt 300mm complete all as specified and directed by Engr-in-charge.
1
-
-
M&L for point wiring with 1.5 Sq mm, FRLS, PVC insulated, single core, unsheathed, multi stranded 1100 volts grade, copper conductor cable drawn through existing concealed conduit on ceiling/wall, with and including continuous 1.5 Sqmm, FRLS, PVC insulated single core multi stranded copper conductor cable earth continuity conductor connected to common earth and earth dolly and including metal sheet enclosure rectangular terminal boxes of suitable size and white cover plates suitable for mounting modular switches, sockets etc all as specified and directed for :- (Note : Conduit and accessories if required to be repalced will be measured and paid separately)
-
-
-
One light/fan point controlled by one switch, one way switch single pole.
3
-
-
One 3 pin 5 Amp socket outlet on the same board .
1
-
-
One 3 pin 5 Amp socket outlet on independent board
1
-
-
All as per item No. 79 here in before but with 2.5 sqmm copper conductor cable for one 3 pin, 15 amps socket out let on independent board.
1
-
-
Supply and fix modular switch type 230/ 250 volts, 6 amps, 1 module, single pole, one way, complete all as directed.
5
-
-
Supply and fix modular socket out let multi purpose 2 in 1, 2/3 pin, 6 amps, flush type, ISI marked complete all as directed.
2
-
-
Supply and fix switch modular 16 amps, flush type, ISI marked complete all as directed.
1
-
-
Supply and fix socket 2/3 pin combined, 6/16 amps, flush type, ISI marked complete all as directed.
1
-
-
Supply and Fixing Ceiling Rose Surface PVC type 65 x 50 mm two to three terminals.
3
-
-
Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor complete all as directed.
1
-
-
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
2
-
-
Supply and Fixing Sheet metal enclosure for DBs when MCBs to be Used, 4 way, SPN, double door type, 240 Volt with 200 amps rated busbar complete all as directed.(Note : MCBs will be Measured separately)
1
-
-
Supply and Fixing MCB, SPN, 230 Volt of capacity 6 to 32 Amps(as ordered), 10 KA 'C' series complete all as directed.
1
-
-
Supply and Fixing MCB, SP, 230 Volt of capacity 6 to 32 Amps(as ordered), 10 KA 'C' series complete all as directed.
2
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core complete.
30
-
-
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables.
2.5
-
-
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable.
1
-
-
M & L brick protection cover cable of "Sub class 'B' laid dry over cable (length of brick shall be laid across the length of cable) complete all as specified and directed.
0.16
-
-
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion, complete all as directed.
1
-
-
Schedule of credit amount of Rs. 0.00 to be deducted during AOC
-
-
-