Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date20 Sep 2024
Closing Date24 Oct 2024
Tender Amount₹ 25,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Retuming, filling in including spreading, levelling, watering and well ramming excavated soil in layers not Cum 25 exceeding 25 cm thick each, back in trenches after cables have been laid and tested,poles, stays, struts have been erected and tested, all as specified and directed at site.

39.69

-

-

... More
Removing excavated surplus soil (Soft/hard soil) obtained from excavation to a distance not exceeding 50 Cum 20 mtr and deposting where directed at a level not exceeding 1.5m above the starting point all as specified and directed.

41.31

-

-

... More
Supply and laying sand cushioning for cable protection in trenches 8 cm before laying cable and 15 cm deep over the cable all as specified.

24.3

-

-

... More
Supply laying bricks old size sub class B bricks common brunt bldg bricks laid in trenches for cable protection complete, all as specified and directed.

4.95

-

-

... More
M&L for cutting PCC/floor/road and taking out cable and making good, with material as per existing after laying of pipe for cable protection including Cement concrete work in pavement/ hard-standing of frexural strength 40kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less all as specified and directed size of trench not more than 0.30 x 0.30 cm.

1

-

-

... More
S&F in replacement of GI Pipe medium grade on wall/floor for cable protection with fixing arrangement size 50mm dia.

12

-

-

... More
Taking out old unserviceable LT under ground cable of any size and rating.

600

-

-

... More
Supply and Laying XLPE heavy duty armoured electric under ground cable aluminum conductor 1100 V grade in trenches/on pole through sleeves etc. all as specified and directed.

-

-

-

... More
(a) Cross sectional area 70 Sqm 3.5 Core

300

-

-

... More
(b) Cross sectional area 50 Sqm 3.5 Core.

300

-

-

... More
M&L for indoor/outdoor end terminations Joints kit (Epoxy) Cable Joint Kit including Jointing Materials for making Joints of UG Electric Cable 1100 Volt Grade Heavy Duty with PVC/XLPE insulated Aluminium Stranded Conductor, nominal Cross-Sectional area from 4 Sqmm upto 16 Sqmm, 3½ Core and Testing complete all as specified and as directed.

10

-

-

... More
M&L for indoor/outdoor end terminations Joints kit (Epoxy) Cable Joint Kit including Jointing Materials for making Joints of UG Electric Cable 1100 Volt Grade Heavy Duty with PVC/XLPE insulated Aluminium Stranded Conductor, nominal Cross-Sectional area from 25 Sqmm upto 50 Sqmm, 3½ Core and Testing complete all as specified and as directed.

10

-

-

... More
M&L for indoor/outdoor end terminations Joints kit (Epoxy) Cable Joint Kit including Jointing Materials for making Joints of UG Electric Cable 1100 Volt Grade Heavy Duty with PVC/XLPE insulated Aluminium Stranded Conductor, nominal Cross-Sectional area from 70 Sqmm upto 150 Sqmm, 3½ Core and Testing complete all as specified and as directed.

10

-

-

... More
M&L for indoor/outdoor end terminations Joints kit (Epoxy) Cable Joint Kit including Jointing Materials for making Joints of UG Electric Cable 1100 Volt Grade Heavy Duty with PVC/XLPE insulated Aluminium Stranded Conductor, nominal Cross-Sectional area from 185 Sqmm upto 300 Sqmm, 3½ Core and Testing complete all as specified and as directed.

10

-

-

... More
M&L for outdoor/indoor LT panel board/Capacitor Panels/feeder pillar boxes with welding of front/Back side Job covers, necessary hinges, locking system with 300mm long MS sliding door bolt 16 mm dia, rubber gasket of appropriate size including proper fixing with nuts bolts etc with minor spare parts and spray painting with one coat of synthetic enamel paint outer and inner side with two coat of lime wash on plinth of panel board included connected accessories in any size.

20

-

-

... More
Supply and replace MCCB, 4 pole , 50 Hz capacity (thermal adjustable type) all as specified and directed for following capacity

-

-

-

... More
(a) 400 Amps with 36 KA rupturing capacity

2

-

-

... More
(b) 250 Amps with 36 KA rupturing capacity

2

-

-

... More
(c) 200 Amps with 36 KA rupturing capacity

2

-

-

... More
(d) 160 Amps with 36 KA rupturing capacity

2

-

-

... More
(e) 100 Amps with 16 KA rupturing capacit

2

-

-

... More
Supply and replace MCCB 3 pole, 50 Hz capacity 36 KA rupturing capacity (thermal adjustable type) all as specified and directed for following capacity.

-

-

-

... More
(a) 400 Amps

2

-

-

... More
(b ) 250 Amps

2

-

-

... More
(c) 200 Amps

2

-

-

... More
(d) 150 Amps

2

-

-

... More
Trimming/Cuting of bushes and grass of Substations/MES Installations and surrounding of Panel board feeder piller boxes at various location and dumping/staging 50 mtr from existing point all as specified and directed.

600

-

-

... More
Cutting and Trimming of tree branches touching LT over head lines & clear the vegetation / grass around the LT pole maintain a clearance of 1.50 M radius of the pole and trimming of branches in each span of LT over head line complete all as specified and directed by Engr-in-Charge. Note: (a) an area of 1.5 M surrounding the pole to be cleared off vegetation/grass & cutting of trees branches. (b) The item shall be repeated after three months from the date of first trimming as directed by Engr in charge. (d) Measurement and payment will be made for each cutting/ trimming as a job.

600

-

-

... More
Testing of capacitor and taking out old unserviceable cpacitor of any capacity form capacitor panel from substations located at Dronachal area all as specified and directed

40

-

-

... More
Supply and fixing long life mixed dielectric capacitors 440V, 3 phase, 50Hz confirming to IEC-60831-1 & 2. with over pressure device for disconnection, having low energy losses (≤ 0.2W/KVAR), resistance to high temperature range (-25°C +70°C) of following KVAR (including safety cap) with minimum 1 year warranty, Including all wiring work for making capacitor functional in all respect complete all as specified for following KVAR:-

-

-

-

... More
(a) 5 KVAr

10

-

-

... More
(b) 7.5 KVAr

10

-

-

... More
(c) 10 KVAr

10

-

-

... More
(d) 20 KVAr

10

-

-

... More
Taking out old unsv MCB/Multifunctional meter of any size any description and issuing under schedule of credit

40

-

-

... More
S&F in existing panel, LED multifunction meters for showing parameters, V.A.F.PF.KW/KVA,KVAR, kWh,kVARh, Runhours etc complete all as specified and directed Make Neptune model No: M-9 power analyser or equivalent in L&T modelA, confirming with RS485 port

10

-

-

... More
S&F in existing panel of MCB TP 40A 10kA complete all as specified and directed.

10

-

-

... More
S&F in existing panel of MCB TP 63A 10kA complete all as specified and directed.

10

-

-

... More
S&F in existing panel of MCB SP 10A 10kA complete all as specified and directed.

10

-

-

... More
Taking out old unsv LED indication lamp on-off switch of any size any description.

100

-

-

... More
S&F in existing panel LED indication lamps(Pilot lamp 22.5mm, metalic) with integral curcuit LED suitable for operating at 200 V AC SP (R/Y/B Phase) complete all as specified and directed by Eng-in-Charge.

50

-

-

... More
S&F in existing panel, LED type Start push button, flush illuminated actuator, with integral circuit LED, suitable for operating range 220V AC complete all as specified and directed by Eng-in-Charge.

20

-

-

... More
S&F in existing panel LED type Stop push button, flush illuminated actuator, with integral circuit LED, suitable for operating range 220V AC complete all as specified and directed by Eng-in-Charge.

20

-

-

... More
S&F in existing panel, Rotary switch (Auto-Manual) 3Phase, 2KW, 25Amp capacity complete all as specified and directed by Eng-in-Charge.

10

-

-

... More
Taking out old unsv APFC relay of any size any description complete all as specified and directed by Eng-in-Charge.

15

-

-

... More
S&F in existing panel, automatic power factor controller for automatic power controller for automatic switching of capocitor of minimum 8 rammable (single phase controller) complete all as specified and directed5Stages complete all as specified and directed by Eng-in-Charge.

5

-

-

... More
M & L for Calliberation of APFC Relay fixed in existing panel complete all as specified and directed.

10

-

-

... More
Taking out old unsv capacitor duty contactors of any size any description complete all as specified and directed

55

-

-

... More
S&F in existing panel, capacitor duty contactor 3 pole, AC with auxililiary contacts 1NO+1NC, 2NC including AC coil with operating voltage 220V complete with all accessories and making all connection wiring complete all as specified and directed. suitable for following capacity:-

-

-

-

... More
(a) 5 KVAR

5

-

-

... More
(b) 10 KVAR

10

-

-

... More
(c) 15 KVA

20

-

-

... More
(d) 20 KVAR

20

-

-

... More
S&F in repair power contactor rating AC1, 80 Amps to 125 Amps, 415 Volts including fitting in exist panel Each with electrical connection complete all as specified and directed by Eng-in-Charge.

4

-

-

... More
S&F in repair change over switch 200 Amps 415 V, AC 23 A 4 pole type CO2-200 confirming to IEC 60947- Each 3 direct handle version fitting in exist panel with electrical connection complete all as specified and directed by Eng-in-Charge.

2

-

-

... More
Supply and replacement of Existing LT panel front/back door with 3.0mm thickness MS sheet powder Each coating paint including locking arrangement complete all as specified and directed by Eng-in-Charge.

5

-

-

... More
Supply and replacement of LT panel busbar in repair as per existing size and PVC shrinkable sleeving with RYB colours for 4 Nos busbar complete all as specified and directed by Eng-in-Charge.

6

-

-

... More
S&F in replacement current transformer 200/5 ratio 240 Volts complete.

10

-

-

... More
S&F in replacement current transformer 400/5 ratio 240 Volts complete.

10

-

-

... More
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with RM inner sheathing of PVC tape and overall PVC sheathed wire, one twin core cable fiat 6 Sqmm complete.

300

-

-

... More
Repair only automatic transfer switch 250 Amps and replacement of handle and necessary spare parts Each including testing complete all as specified and directed by Eng-in-Charge.

2

-

-

... More
M&L for fixing the name board fabricated with MS Sheet 2mm thick of size 1.5x3 feet and fixed with suitable GI Clamp on 2/4 pole structure including writing the detail of Sub Stn and feeder etc with blue background & white colour Letter complete all as specified and directed by Eng-in-Charge.

20

-

-

... More
Supply and installation, testing & commissioning self supporting totally enclosed factory fabricated LT bus Each bar panel box made out of 3.15mm thick MS sheet with projected globe roof for rain water protection, dust and vermin proof hinged double shutter doors with neorprene rubber gasket epoxy powder coated including danger plate, earth strip, ventilation louvers, bottam detachable gland plate complete with suitable size zinc chromium plated nuts, bolts, and washers etc outdoor type cubicle panel board suitable for 3 Feeder phase 4 wire 415 volt 50 HZ and 40 mm x 40 mm x 6 mm angle iron frame, weather proof ventilated with locking arrangement incl of PCC pedestal, comprising the following & including taking down the existing Pillar panel board- (i) Aluminium bus- bar 400Amps,supported with suitable size Porcelain standlock with suitable size brass nut, bolts and washers with heat shrinkable colour coded PVC sleeving for 3 phase & neutral . - 01 Set (ii) MCCB with microprocessor release ,4 pole, 250amps ,36 KA, 415 Volts, 50 Hz Adjustable - 01 No

5

-

-

... More
M & L for disconnect the elect supply including taking out and refixing in position, connecting, commissioning after repair/replacement of unserviceable parts of ACB’s of capacity 1000/800A as follows. Note: Spare parts to be included as per requirement. (a)  Replacement of castle lock (Z244C) as existing-02 nos (b)  Replacement of Gear mother (ZMCH) as existing-02 nos (c)  Replacement of earth fault relay (ZEFR) 415 V, AC 50 HZ, 3 phase, 3 wire system-02 nos (d)  Replacement of auxiliary contact (601) as per existing make and rating-02 nos

5

-

-

... More
Disconnection, taking down, dismantling including necessary testing for Voltage stabilizer 25 KVA capacity and necessary repair work/labour :-Opening top cover carefully without damaging any part and detecting the fault/defects in core by testing , Disconnecting the defective coil and rewinding the same with suitable guage of super enamelled copper conductor as per the existing size for the limbs as required at site, Minor spares like nuts bolts, washers and otheritems, required for completion of the job are deemed to be included in the rates quoted., major spare parts shall be measured and paid seperately as supply only under relevant items given below:-

1

-

-

... More
(a) Push button switch

1

-

-

... More
(b) Auto manual switch

1

-

-

... More
(c) Analog ammeters, with CT, 0-100 Amps square type, size 96 x 96 sqm, surface mounting type, complete all as specified and directed

1

-

-

... More
Supply and earth continuity conductor or main earthing lead 32 x 6 mm GI strip laid in pipe/fixed to poles or any other indicated situation including jointing by using Gl nuts, bolts, washer and saddle in addition to welding complete all as specified and directed.

250

-

-

... More
M&L for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 50mm dia GI pipe medium grade and connected to pole structure/ panel board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II

9

-

-

... More
M&L for earthing complete with copper earth plate electrode 600mm x 600mm x 3.15 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to copper strip 20x3 mm as earthing lead by means of bolts, nuts, check nuts and washers of copper and earth wire protected by 50mm dia GI pipe medium grade and connected to pole structure/ panel board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II

11

-

-

... More
M&L for Chemical earthing as per 'ASHLOK" make model T-39 zinc coated safe earthing electrode (SEE) of 3 mtr length with inner pipe of 40 mm dia with min 80-100 micron coating filled with black fill compound mixed with soil and high specific gravity crystalline conductive mixture (CCM) of grade 'B' filled inside the earth electrode incl drilling of hole of 200 mm dia bore with boring machine up to 15 mtrs depth in hard rock and filling the bore hole with black cotton soil up to 17 mtrs level i.e. below the electrode bottom level, incl PCC earth pit and GI earth strip of 32x6 mm with GI tubing light grade for protection up to 7.5 mtrs complete all as specified and directed.

6

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.