Military Engineer Services Tender

... More
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date4 Sep 2024
Closing Date5 Oct 2024
Tender Amount₹ 49,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Diasmantling of ACSR or AAC conductors of any size from LT poles or distrubution span complete all as specified and directed.

1.2

-

-

... More
Fixing only binding from disc/shackle/loop insulator etc and rebinding after tightening/restringing of AACSR/AAC/LT over head conductors of any size with and including 14 SWG binding wire and testing complete all as specified and directed.

0.6

-

-

... More
M&L for binding from disc/shackle/loop insulator etc and rebinding after tightening/restringing of AACSR/AAC/LT over head conductors of any size with and including 14 SWG binding wire and testing complete all as specified and directed.

0.2

-

-

... More
Dismantling GI wire of any size from LT poles or distrubution span & removal from site complete all as specified and directed.

0.4

-

-

... More
Fixing only binding from disc/shackle/loop insulator etc and rebinding after tightening/restringing of Galvanised steel wire 3.15 or 4 mm dia LT over head earth wire, complete all as specified & directed.

0.2

-

-

... More
M&L for stretching and then stengthening of over head Galvanised steel wire 3.15 or 4mm dia on existing LT poles including binding & jointing the conductor and testing complete all as specified and directed.

0.2

-

-

... More
M&L for Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size, for LT, 20 x 15 cm size complete all as specified and directed.

40

-

-

... More
Dismantling/taking out of defective broken unserviceable insulators of any type and including MS spindles GI washers, nuts etc and S&F insulators pin/shockle type porcelain viterous white/brown or green insulator including on galvanised mild steel spindle, two GI washers & one GI nut, 100 mm height and 65 mm dia suitable for working pressure 1100 Volts grade complete all as specified and directed.

20

-

-

... More
S&F PVC Seperator 2 way for LT O/H electric line complete all as specified and directed.

10

-

-

... More
S&F PVC Seperator 4 way for LT O/H electric line complete all as specified and directed.

8

-

-

... More
S&F, erection steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolt, nut & screws as specified type 410 SP-31 (9.00 meter long), painting with two coat of aluminium paint over one coat of red oxide primer and marking pole Nos with black sythetic enamelled paint including tarring one coat of steel surface embedded in concrete complete all as specified and as directed. Note : Earth work and PCC shall be measured and paid separately.

2

-

-

... More
Dismantling of LT Steel Tubular poles and setting aside for re-use within 50 metres complete all as specified and directed. Note : Excavation, RFR, Removal and PCC shall be measured and paid separately.

2

-

-

... More
Demolition of cement concrete unreinforced in ground floors and pavings n.exc15 cm thickness (below or above ground level) complete all as specified and directed.

1

-

-

... More
M&L for PCC 1:4:8, type D-2 using 40 mm graded stone aggregate as in filling & mass concrete complete all as specified and directed.

0.4

-

-

... More
M&L for PCC 1:3:6, type C-1 using 20 mm graded stone aggregate as in coping of pole etc including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified and directed.

0.4

-

-

... More
M&L for cutting/trimming the trees branches size n.exc 80 mm dia at height of exc 3.0 m but n.exc 12.0 m crossing/touching/ embracing the overhead lines of HT/LT and obstructing the uniform electric power supply including removing the same from site to a distance exceeding 50 mtr complete all as specified and directed.

80

-

-

... More
M&L for cutting/trimming the trees branches size exc 80 mm dia but n.exc 150 mm at height of exc 3.0 m but n.exc 12.0 m crossing/touching/ embracing the overhead lines of HT/LT and obstructing the uniform electric power supply including removing the same from site to a distance exc 50 m complete all as specified and directed.

20

-

-

... More
M&L for excavation in trenches n.exc 1.5 m wide depth exc 1.5 m but n.exc 3.0 m, for foundation of poles/stays etc and getting out in any type of soil complete all as specified and dirtected.

1.6

-

-

... More
M&L for excavating in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 sqm on plan and n. exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and dirtected.

318.4

-

-

... More
M&L for returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc 25 cm in soft/ loose soil complete all as specified and dirtected.

200

-

-

... More
M&L for removing excavated materials n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and dirtected.

118.4

-

-

... More
M&L for unwashed Sand cushioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified and directed. Note : maesurement shall be done after puning down of sand.

94

-

-

... More
M&L for Fly Ash bricks Sub-class 'B' locally available laid flat in trenches over sand cushioning for cable protection complete all as speciffied and directed.

10000

-

-

... More
M&L for crossing hole under road/hard stranding for passing cable through GI pipe including GI pipe light grade 32 mm dia with all fittings complete all as specified and directed.

20

-

-

... More
M&L for crossing hole under road/hard stranding for passing cable through GI pipe including GI pipe light grade 40 mm dia with all fittings complete all as specified and directed.

20

-

-

... More
M&L for crossing hole under road/hard stranding for passing cable through GI pipe including GI pipe light grade 50 mm dia with all fittings complete all as specified and directed.

16

-

-

... More
M&L for crossing hole under road/hard stranding for passing cable through GI pipe including GI pipe light grade 80 mm dia with all fittings complete all as specified and directed

2.4

-

-

... More
Taking down existing old existing unserviceable LT UG/service cable of any description and size complete all as specified and directred.

1540

-

-

... More
S&F XLPE insulated armoured and PVC sheated heavy duty electric cable with aluminium conductor 1100 Volts grade laid in tranches passing through pipes/ducts including testing of following cross sectional area and size complete all as specified and directed. Note :- Rate is inclusive of cable gland & cable lugs.

-

-

-

... More
2 Core x 10 Sqmm

160

-

-

... More
4 Core x 10 Sqmm

200

-

-

... More
4 Core x 16 Sqmm

200

-

-

... More
4 Core x 25 Sqmm

280

-

-

... More
3.5 Core x 35 Sqmm

280

-

-

... More
3.5 Core x 50 Sqmm

160

-

-

... More
3.5 Core x 70 Sqmm

80

-

-

... More
3.5 Core x 95 Sqmm

80

-

-

... More
3.5 Core x 120 Sqmm

40

-

-

... More
3.5 Core x 150 Sqmm

40

-

-

... More
3.5 Core x 240 Sqmm

20

-

-

... More
M&L for repair/maint of floor indoor/outdoor cubical type LT Feeder Pillar Box of various sizes including disconnecting all incoming and outgoing connection after taking necessary shut down, cleaning the carbon/rust from bus-bar, re-thimbling with new lugs/thimble of existing size incl. and segregating the serviceable and un-serviceable items with removing old burn out wiring and re-fixing the existing position replacement of unserviceable parts including rewiring and PCC works around the Feeder Pillar Box complete all as specified and directed.

6

-

-

... More
S&F MCCB 63 Amps, 4 Pole, 415 Volts, with breaking capacity 16 KA complete all as specified and directed.

4

-

-

... More
S&F MCCB 100 Amps, 4 Pole, 415 Volts, with breaking capacity 16 KA complete all as specified and directed.

2

-

-

... More
M&L for MCCB 4 Pole, 415 Volts, Adjustable type 160 Amps with breaking capacity 36 KA complete all as specified and directed.

2

-

-

... More
M&L for MCCB 4 Pole, 415 Volts, Adjustable type 200 Amps with breaking capacity 36 KA complete all as specified and directed.

2

-

-

... More
M&L for MCCB 4 Pole, 415 Volts, Adjustable type 350 Amps with breaking capacity 36 KA complete all as specified and directed.

2

-

-

... More
M&L for MCCB 4 Pole, 415 Volts, Adjustable type 400 Amps with breaking capacity 36 KA complete all as specified and directed.

3

-

-

... More
M&L for MCCB 4 Pole, 415 Volts, Adjustable type 630 Amps with breaking capacity 50 KA complete all as specified and directed.

1

-

-

... More
S&F ACB 4 Pole, 415 Volts, beaking capacity 50 KA with Thermal Magnetic Release (Manual Fixed type) of capacity 800 Amps complete all as specified and directed.

1

-

-

... More
S&F in replacement of Digital time switch including 3 phase power contactor 40 Amps complete all as specified and directed.

3

-

-

... More
Dismantling and taking down street light fittings any size and re-fixing again after erecting of LT pole etc complete all as specified and directed.

5

-

-

... More
S&F Cable junction box for street lights of size 155 x 210 x 92 mm, IP 66 with integrated membranes/metric knockouts for cable entry of 10 to 25 Sqmm LT UG cable suitable for 415 volts, 50 Hz, 3 phase, 4 wire including clamp made out of MS flat 30 x 5 mm, nuts, bolts, washers etc complete and mounted on security light pole complete all as specified and directed. Make ; Hensel cat Part No - DK 2525G with terminals

30

-

-

... More
S&F LED street light fitting 35 Watts, 230 Volts, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics including brackets for fixing complete with IP-65/66 protection complete all as specified and directed.

40

-

-

... More
S&F LED street light fitting 60 Watts, 230 Volts, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal mangement in multiple optics compete with IP-65/66 protection complete and taking down old unsv street light fitting and type and any wattage complete all as specified and directed.

111

-

-

... More
S&F LED flood light fitting 70 Watts, 230 Volts, AC outdoor type with thermal mangement in multiple optics and equipped with IP-66 protection with impact corrosion resistant complete with driver and lamp and taking down old unsv flood light fitting and type and any wattage complete all as specified and directed.

12

-

-

... More
Supply, install, commissioning and testing of CPRI approved factory fabricated, floor mounted outdoor type LT Feeder Pillar Box of suitable size fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 x 50 x 6 mm frame and 750 mm above the normal ground level complete factory made totally enclosed dust and vermin proof double door both side hinge opening arrangement on front and back with locking arrangement cable entry and exist from bottom with cable glands and gaskets, aluminium bus bar 250 Amps rating (01 Set) fixed on porcelain insulator with internal wiring with suitable size of aluminium strips to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. Bus-bar shall be insulated with colour code sleeves/tapes and to be connected with copper lugs, including two coats of synthetic enameled paint on the surface externally & internally over a coat of red oxide primer paint incl. necessary PCC (1:3:6) type C-2 as in foundation complete all as specified and directed, comprising of the following :-

1

-

-

... More
(a) INCOMING

-

-

-

... More
(i) Thermal magnetic and micro processor release MCCB 250 Amps, 4 Pole, 36 KA with front operated locking device - 01 Nos

-

-

-

... More
(b) OUTGOING

-

-

-

... More
(i) Thermal magnetic MCCB 63 Amps, 4 Pole, 415 Volts, 16 KA. Qty - 03 Nos

-

-

-

... More
(ii) MCB 32 Amps, 2 Pole. Qty - 01 Nos

-

-

-

... More
(c) Digital time switch including 3 phase power contactor 40 Amps. Qty - 01 Nos

-

-

-

... More
(d) (i) Digital Voltmeter 0-500 Volts with selector switch - 1 Set.

-

-

-

... More
(ii) Digital Amperemeter 0-200 Amps with selector switch - 1 Set.

-

-

-

... More
(iii) Indicator Lamp - R - Y - B (Set of three).

-

-

-

... More
(iv) Frequency meter 40-55 Hz - 01 Nos

-

-

-

... More
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level connecting to and including GI earth wire of size 4.0 mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia medium grade pipe for protection of GI wire to the extent of 7.5 m as earthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical Plate No 3 of SSR Part- I (2009) including PCC foundation/chamber in mix 1:2:4 type B1 with angle iron frame CI frame, CI cover with provision of locking arrangement and 20 mm dia light grade GI pipe from top edge of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal ( for street light poles) complete all as specified and directed. Note :- Earth protection pipe & earthing wire upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.

3

-

-

... More
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level connecting to and including GI steel strip of size 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 40 mm dia medium grade pipe for protection of GI strip to the extent of 7.5 m as earthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical Plate No 3 of SSR Part-I (2009) including PCC foundation/chamber in mix 1:2:4 type B1 with angle iron frame CI frame, CI cover with provision of locking arrangement and 20 mm dia light grade GI pipe from top edge of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal ( for LT Panels) complete all as specified and directed. Note :- Earth protection pipe & earthing strip upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.

15

-

-

... More
S&F 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served wth inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0 m apart inccluding 4 mm susension wire, one twin core aluminium conductor of size 6 Sqmm flat or circular from junction box to street light fitting complete all as specified and directed.

150

-

-

... More
M&L for boring of holes under road/pavement/hard standing by trenchless technology with neccessary machineries for inserting the GI pipe of size upto 80 mm working pressuredia complete all as specified and directed.

35

-

-

... More
(UNRESTRICTED AREA SCHEDULE)

-

-

-

... More
M&L for painting carefully (by taking necessary shut down from respective sub-station) on steel tubular poles 9 m long (7.5 m from ground level) including cross arms, bracings, clamps, cable protection pipes, street light clamps (fix to poles) with two coats of aluminium paint including preparation of surface and writing Pole No with paint (letters height not less than 10 cm) complete all as specified and directed.

120

-

-

... More
M&L for painting carefully (by taking necessary shut down from respective sub-station) on LT PCC Poles 9 m lomg (7.5 m from ground level) and applying two coats of cement base paint over a coat of alkalines resistant primer to surface of concrete pole and M&L for two coats of synthetic enamel paint including preparation of surfaces of cross arms, bracings, clamps, cable protection pipes, street light clamps (fix to poles) and writing Pole No with paint (letters height not less than 10 cm) complete all as specified and directed.

30

-

-

... More
Diasmantling of ACSR or AAC conductors of any size from LT poles or distrubution span complete all as specified and directed.

1.8

-

-

... More
Fixing only binding from disc/shackle/loop insulator etc and rebinding after tightening/restringing of AACSR/AAC/LT over head conductors of any size with and including 14 SWG binding wire and testing complete all as specified and directed.

0.9

-

-

... More
M&L for binding from disc/shackle/loop insulator etc and rebinding after tightening/restringing of AACSR/AAC/LT over head conductors of any size with and including 14 SWG binding wire and testing complete all as specified and directed.

0.3

-

-

... More
Dismantling GI wire of any size from LT poles or distrubution span & removal from site complete all as specified and directed.

0.6

-

-

... More
Fixing only binding from disc/shackle/loop insulator etc and rebinding after tightening/restringing of Galvanised steel wire 3.15 or 4 mm dia LT over head earth wire, complete all as specified & directed.

0.3

-

-

... More
M&L for stretching and then stengthening of over head Galvanised steel wire 3.15 or 4mm dia on existing LT poles including binding & jointing the conductor and testing complete all as specified and directed.

0.3

-

-

... More
M&L for Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size, for LT, 20 x 15 cm size complete all as specified and directed.

60

-

-

... More
Dismantling/taking out of defective broken unserviceable insulators of any type and including MS spindles GI washers, nuts etc and S&F insulators pin/shockle type porcelain viterous white/brown or green insulator including on galvanised mild steel spindle, two GI washers & one GI nut, 100 mm height and 65 mm dia suitable for working pressure 1100 Volts grade complete all as specified and directed.

30

-

-

... More
S&F PVC Seperator 2 way for LT O/H electric line complete all as specified and directed.

15

-

-

... More
S&F PVC Seperator 4 way for LT O/H electric line complete all as specified and directed.

12

-

-

... More
S&F, erection steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolt, nut & screws as specified type 410 SP-31 (9.00 meter long), painting with two coat of aluminium paint over one coat of red oxide primer and marking pole Nos with black sythetic enamelled paint including tarring one coat of steel surface embedded in concrete complete all as specified and as directed. Note : Earth work and PCC shall be measured and paid separately.

3

-

-

... More
Dismantling of LT Steel Tubular poles and setting aside for re-use within 50 metres complete all as specified and directed. Note : Excavation, RFR, Removal and PCC shall be measured and paid separately.

3

-

-

... More
Demolition of cement concrete unreinforced in ground floors and pavings n.exc15 cm thickness (below or above ground level) complete all as specified and directed.

3

-

-

... More
M&L for PCC 1:4:8, type D-2 using 40 mm graded stone aggregate as in filling & mass concrete complete all as specified and directed.

0.6

-

-

... More
M&L for PCC 1:3:6, type C-1 using 20 mm graded stone aggregate as in coping of pole etc including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified and directed.

0.6

-

-

... More
M&L for cutting/trimming the trees branches size n.exc 80 mm dia at height of exc 3.0 m but n.exc 12.0 m crossing/touching/ embracing the overhead lines of HT/LT and obstructing the uniform electric power supply including removing the same from site to a distance exceeding 50 mtr complete all as specified and directed.

120

-

-

... More
M&L for cutting/trimming the trees branches size exc 80 mm dia but n.exc 150 mm at height of exc 3.0 m but n.exc 12.0 m crossing/touching/ embracing the overhead lines of HT/LT and obstructing the uniform electric power supply including removing the same from site to a distance exc 50 m complete all as specified and directed.

30

-

-

... More
Excavation in trenches n.exc 1.5 m wide depth exc 1.5 m but n.exc 3.0 m, for foundation of poles/stays etc and getting out in any type of soil complete all as specified and dirtected.

2.4

-

-

... More
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 sqm on plan and n. exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and dirtected.

477.6

-

-

... More
Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc 25 cm in soft/ loose soil complete all as specified and dirtected.

300

-

-

... More
Removing excavated materials n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and dirtected.

177.6

-

-

... More
M&L for unwashed Sand cushioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified and directed. Note : maesurement shall be done after puning down of sand.

141

-

-

... More
M&L for Fly Ash bricks Sub-class 'B' locally available laid flat in trenches over sand cushioning for cable protection complete all as speciffied and directed.

15000

-

-

... More
M&L for crossing hole under road/hard stranding for passing cable through GI pipe including GI pipe light grade 32 mm dia with all fittings complete all as specified and directed.

30

-

-

... More
M&L for crossing hole under road/hard stranding for passing cable through GI pipe including GI pipe light grade 40 mm dia with all fittings complete all as specified and directed.

30

-

-

... More
M&L for crossing hole under road/hard stranding for passing cable through GI pipe including GI pipe light grade 50 mm dia with all fittings complete all as specified and directed.

24

-

-

... More
M&L for crossing hole under road/hard stranding for passing cable through GI pipe including GI pipe light grade 80 mm dia with all fittings complete all as specified and directed

3.6

-

-

... More
Taking down existing old existing unserviceable LT UG/service cable of any description and size complete all as specified and directred.

2310

-

-

... More
S&F XLPE insulated armoured and PVC sheated heavy duty electric cable with aluminium conductor 1100 Volts grade laid in tranches passing through pipes/ducts including testing of following cross sectional area and size complete all as specified and directed. Note :- Rate is inclusive of cable gland & cable lugs.

-

-

-

... More
2 Core x 10 Sqmm

240

-

-

... More
4 Core x 10 Sqmm

300

-

-

... More
4 Core x 16 Sqmm

300

-

-

... More
4 Core x 25 Sqmm

420

-

-

... More
3.5 Core x 35 Sqmm

420

-

-

... More
3.5 Core x 50 Sqmm

240

-

-

... More
3.5 Core x 70 Sqmm

120

-

-

... More
3.5 Core x 95 Sqmm

120

-

-

... More
3.5 Core x 120 Sqmm

60

-

-

... More
3.5 Core x 150 Sqmm

60

-

-

... More
3.5 Core x 240 Sqmm

30

-

-

... More
M&L for repair/maint of floor indoor/outdoor cubical type LT Feeder Pillar Box of various sizes including disconnecting all incoming and outgoing connection after taking necessary shut down, cleaning the carbon/rust from bus-bar, re-thimbling with new lugs/thimble of existing size incl. and segregating the serviceable and un-serviceable items with removing old burn out wiring and re-fixing the existing position replacement of unserviceable parts including rewiring and PCC works around the Feeder Pillar Box complete all as specified and directed.

9

-

-

... More
S&F MCCB 63 Amps, 4 Pole, 415 Volts, with breaking capacity 16 KA complete all as specified and directed.

4

-

-

... More
S&F MCCB 100 Amps, 4 Pole, 415 Volts, with breaking capacity 16 KA complete all as specified and directed.

5

-

-

... More
M&L for MCCB 4 Pole, 415 Volts, Adjustable type 160 Amps with breaking capacity 36 KA complete all as specified and directed.

3

-

-

... More
M&L for MCCB 4 Pole, 415 Volts, Adjustable type 200 Amps with breaking capacity 36 KA complete all as specified and directed.

2

-

-

... More
M&L for MCCB 4 Pole, 415 Volts, Adjustable type 350 Amps with breaking capacity 36 KA complete all as specified and directed.

2

-

-

... More
M&L for MCCB 4 Pole, 415 Volts, Adjustable type 400 Amps with breaking capacity 36 KA complete all as specified and directed.

2

-

-

... More
M&L for MCCB 4 Pole, 415 Volts, Adjustable type 630 Amps with breaking capacity 50 KA complete all as specified and directed.

1

-

-

... More
S&F ACB 4 Pole, 415 Volts, beaking capacity 50 KA with Thermal Magnetic Release (Manual Fixed type) of capacity 800 Amps complete all as specified and directed.

1

-

-

... More
S&F in replacement of Digital time switch including 3 phase power contactor 40 Amps complete all as specified and directed.

3

-

-

... More
Dismantling and taking down street light fittings any size and re-fixing again after erecting of LT pole etc complete all as specified and directed.

5

-

-

... More
S&F Cable junction box for street lights of size 155 x 210 x 92 mm, IP 66 with integrated membranes/metric knockouts for cable entry of 10 to 25 Sqmm LT UG cable suitable for 415 volts, 50 Hz, 3 phase, 4 wire including clamp made out of MS flat 30 x 5 mm, nuts, bolts, washers etc complete and mounted on security light pole complete all as specified and directed. Make ; Hensel cat Part No - DK 2525G with terminals

30

-

-

... More
S&F LED street light fitting 35 Watts, 230 Volts, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics including brackets for fixing complete with IP-65/66 protection complete all as specified and directed.

50

-

-

... More
S&F LED street light fitting 60 Watts, 230 Volts, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal mangement in multiple optics compete with IP-65/66 protection complete and taking down old unsv street light fitting and type and any wattage complete all as specified and directed.

40

-

-

... More
S&F LED flood light fitting 70 Watts, 230 Volts, AC outdoor type with thermal mangement in multiple optics and equipped with IP-66 protection with impact corrosion resistant complete with driver and lamp and taking down old unsv flood light fitting and type and any wattage complete all as specified and directed.

30

-

-

... More
Supply, install, commissioning and testing of CPRI approved factory fabricated, floor mounted outdoor type LT Feeder Pillar Box of suitable size fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 x 50 x 6 mm frame and 750 mm above the normal ground level complete factory made totally enclosed dust and vermin proof double door both side hinge opening arrangement on front and back with locking arrangement cable entry and exist from bottom with cable glands and gaskets, aluminium bus bar 250 Amps rating (01 Set) fixed on porcelain insulator with internal wiring with suitable size of aluminium strips to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. Bus-bar shall be insulated with colour code sleeves/tapes and to be connected with copper lugs, including two coats of synthetic enameled paint on the surface externally & internally over a coat of red oxide primer paint including necessary PCC (1:3:6) type C-2 as in foundation complete all as specified and directed, comprising of the following :-

1

-

-

... More
(a) INCOMING

-

-

-

... More
(i) Thermal magnetic and micro processor release MCCB 250 Amps, 4 Pole, 36 KA with front operated locking device - 01 Nos

-

-

-

... More
(b) OUTGOING

-

-

-

... More
(i) Thermal magnetic MCCB 63 Amps, 4 Pole, 415 Volts, 16 KA. Qty - 03 Nos

-

-

-

... More
(ii) MCB 32 Amps, 2 Pole. Qty - 01 Nos

-

-

-

... More
(c) Digital time switch including 3 phase power contactor 40 Amps. Qty - 01 Nos

-

-

-

... More
(d) (i) Digital Voltmeter 0-500 Volts with selector switch - 1 Set.

-

-

-

... More
(ii) Digital Amperemeter 0-200 Amps with selector switch - 1 Set.

-

-

-

... More
(iii) Indicator Lamp - R - Y - B (Set of three).

-

-

-

... More
(iv) Frequency meter 40-55 Hz - 01 Nos

-

-

-

... More
Supply install commissioning and testing CPRI Approved factory fabricated, floor mounted outdoor type LT Feeder Pillar Box of suitable size fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame and 750mm above the Normal ground level complete factory made totally enclosed dust and vermin proof double door both side hinge opening arrangement on front and back with locking arrangement cable entry and exist from bottom with cable glands and gaskets, aluminium bus bar 600 Amps rating (01 Set) fixed on porcelain insulator with internal wiring with suitable size of aluminium strips to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. Bus-bar shall be insulated with colour code sleeves/tapes and to be connected with copper lugs, including two coats of synthetic enameled paint on the surface externally & internally over a coat of red oxide primer paint including necessary PCC (1 : 3 : 6) type C2 as in foundation complete all as specified and directed, comprising of the following : -

1

-

-

... More
(a) INCOMING

-

-

-

... More
(i) Thermal magnetic and microprocessor release MCCB 400 Amps, 4 Pole, 36 KA with front operated locking device. - 01 Nos

-

-

-

... More
(b) OUTGOING

-

-

-

... More
(i) Thermal magnetic MCCB 63 Amps, 4 Pole, 415V, 16 KA. Qty - 07 Nos

-

-

-

... More
(iii) MCB 40 Amps, 2 Pole. Qty - 01 Nos

-

-

-

... More
(c) Digital time switch including 3 phase power contactor 40 Amps Qty - 01 Nos

-

-

-

... More
(d) (i) Digital Voltmeter 0 - 500 Volts with selector switch - 1 Set.

-

-

-

... More
(ii) Digital Amperemeter 0 - 200 Amps with selector switch - 1 Set.

-

-

-

... More
(iii) Indicator Lamp - R - Y - B (Set of three).

-

-

-

... More
(iv) Frequency meter 40-55 Hz - 01 Nos

-

-

-

... More
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level connecting to and including GI earth wire of size 4.0 mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia medium grade pipe for protection of GI wire to the extent of 7.5 m as earthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical Plate No 3 of SSR Part- I (2009) including PCC foundation/chamber in mix 1:2:4 type B1 with angle iron frame CI frame, CI cover with provision of locking arrangement and 20 mm dia light grade GI pipe from top edge of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal ( for street light poles) complete all as specified and directed. Note :- Earth protection pipe & earthing wire upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.

3

-

-

... More
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level connecting to and including GI steel strip of size 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 40 mm dia medium grade pipe for protection of GI strip to the extent of 7.5 m as earthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical Plate No 3 of SSR Part-I (2009) including PCC foundation/chamber in mix 1:2:4 type B1 with angle iron frame CI frame, CI cover with provision of locking arrangement and 20 mm dia light grade GI pipe from top edge of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal ( for LT Panels) complete all as specified and directed. Note :- Earth protection pipe & earthing strip upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.

15

-

-

... More
S&F post top lantern LED type upto 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.

6

-

-

... More
S&F new generation IP-65 LED post top family energy sanving environmental friendly, long life aestheticall designed with symmetrical light distribution spunaluminium landscape luminaire with high power 15 Watt LED as light source, clear cover offers bright illumination for different applicatons complete all as specified and directed. Make : Havells cat part No. RUBYMINIPT15WLED830PSYMTOPC or equeivalent to Crompton, Orient, Bajaj

4

-

-

... More
S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served wth inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart inccluding 4 mm suspension wire, one twin core aluminium conductor of size 6 Sqmm flat or circular from junction box to street light fitting complete all as specified and directed.

350

-

-

... More
M&L for boring of holes under road/pavement /hard standing by trenchless technology with neccessary machineries for inserting the GI pipe of size upto 80 mm working pressuredia complete all as specified and directed.

80

-

-

... More
Schedule of credit amount of Rs. 1,73,225.00 to be deducted during AOC.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.