Military Engineer Services Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date10 Oct 2024
Closing Date5 Nov 2024
Tender Amount₹ 83,94,000
Costs
EMD
₹ 1,50,910Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_679096_1Bid Award Id
ViewTender No
83947/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Tender documents with errata and amendments
BOQ Items
M&L for use and waste form work to sides of concrete foundation ,footing base of columns ,rafts,raft beam sides and & soffits of foundation and plinth beams for rough finished flat surfaces of concrete complete all as specified and directed.
122
-
-
M&L Plain cement concrete 1:2:4 type B-2 (using 40mm graded stone aggregates) as in wall or retaining walls ,any thickness , size or shape including pilasters ,buttreses columns ,pillars boundary pillars and posts (including caps and bases) complete all as specified and directed.
10
-
-
M& L for Hardcore of gauge n.exc 63 mm, with broken stone or boulderes deposited, spread and levelled in layers n.exc. 15 Cm thick, watered and rammed to a true surface complete all as specifed and directed.
192
-
-
M & L for 100 mm Plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in sub- floors,sub-bases,floors foundation, etc complete all as specifed and directed.
1184
-
-
M&L for 25mm thick PCC (1:2:4) type B-1 using 20 mm graged stone aggregate as in floors finished rough to receive the tiles complete all as specifed and directed.
1184
-
-
M&L for approved earth filling, incl rough excavation n.exc , 1.5 m deep and getting out in soft/loose soils , removing excavated material to a distance exc 500 m and n. exc. 1.oo Km and filling under floor paving or any other locations , including spreading , levellelling in layers n. exc 25 cm watering and well ramming complete all as specified and directed.
554
-
-
M&L for machine Machine cut kota stone slab 20-25 mm thick as in flooring with border laid over screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing to give granite finish , over and including screed bed or beddding layer of mortar 15 mm thick in cement mortar (1:4) complete all as specified and directed. (Note - All exposed edges of Kota stone flooring shall be finished as half round /bullnosed as directed)
1184
-
-
M&L for machine Machine cut kota stone slab 20-25 mm thick as in riser/ steps , skirting, dado and pillars laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing , over and including 10 mm thick backing coat in CM (1:3) complete all as specified and directed.
58
-
-
M&L brick work with sub class 'B' old size bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 , built in cement mortar complete all as specified and directed.
45.94
-
-
M&L for PCC 1:3:6 type C-2 (using 40 mm graded stone aggregates) as in plinth protection 75mm thick finishing the surfaces even & smooth without using extra cement including forming anf filling expension joints 65mm deep x 10mm wide filled with sealing compound grade 'A' complete all as specified and directed.
192
-
-
S&F pre- coated coloured galvalume Aluminum Zinc coating profile pattern steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa and AZ150 as in roof covering/ clading to wall, including crimping sheet at end fixed with self tapping screws complete all as specified and directed.
1296
-
-
S&F 0.5 mm thick galvalume sheet precoated coloured for ridge having tensile strength of 550 Mpa and AZ150 fixing for closing gable truss suitable for profile pattern sheet fixed with self driving screws sheets roofing complete all as specified and directed.
63
-
-
S&F roof trusses ( framed), trused, purlin, crane gantries, raills and fastenings and heavy braket framing (beams, tee , angle,channel or flat sections) including distance pices, cleats etc(welded/reviting) conforming to Fe 410-W (Gde-E250) quality 'A' complete all as specifed and directed.
11043
-
-
S&F structural steel work as in tubular trusses including special shaped washer complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed.
9291
-
-
S&F MS plates (plain or chequered) channels square cut to or notched forming holes with riveted bolted or welded attachment conforming to Fe-410W complete all as specified and directed.
339
-
-
S&F mild steel screw bolts (machine made) with hexagonal / square heads at one end & screwed the other/ screwed both ends, each screwed end to be fitted with washers & one hexagonal or square nut, length of bolt exc 22.5cm & not exc 30cm long, dia of shank 16 to 20 mm complete all as specified and directed.
21
-
-
M&L Preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer of surfaces over 10cm width or girth, complete all as specifed and directed.
813
-
-
M & L for rendering 15mm thick cement plaster on wall in cement mortar 1:4 on brick wall / Concrete surfaces of finishing the surfaces even and smooth complete all as specifed and directed.
129
-
-
M &L for applying three coats of white wash on newly plastered wall surfaces including preparation of these surfaces complete all as specifed and directed.
129
-
-
M&L for surface point wiring with 1.5 Sqmm PVC-FRLSH insulated, sheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC casing & caping/conduit, including modular metal/PVC flush boxes & modular white cover plate with frame as per site requirement all fittings such as tees, bends, elbows, etc. of External diameter 20mm all as per site requirements PVC insulated & sheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and directed.
-
-
-
For one light, fan point controlled by one switch complete all as specified and directed
63
-
-
For one 5 Amp independent socket point controlled by one switch complete all as specified and directed
6
-
-
For one 3 pin ,5 Amp socket point with other switch on the same board complete all as specified and directed
6
-
-
All as per item No 23 here in before but for power point wiring using with 4 sqmm PVC-FRLSH LSH insulated ,sheathed, copper conductor stranded 1100 volt grade cable and 4 sqmm PVC insulated ,sheathed, copper conductor stranded 1100 volt grade cable as continuous earth lead complete all as specified and directed.
3
-
-
S&F Modular switch, one way, 6 Amp 230, 1 module complete all as specified and directed.
75
-
-
S&F socket Modular 6 Amp-2/3 pin combined 2 module complete all as specified and directed
12
-
-
S&F switch Modular, single pole, one way,16 Amp ,1 module 230 Volt complete all as specified and directed
3
-
-
S&F socket modular 6/16 Amp, 2/3 pin combined ,2 module 230 Volt complete all as specified and directed.
3
-
-
S&F ceiling rose, surface backlite,three terminal complete all as specified and directed.
63
-
-
S&F modular fan step regulator 120W 2 module complete all as specified and directed.
42
-
-
Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
21
-
-
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed
42
-
-
S&F testing and commissioning of MCB SP 6 Amp to 32 Amp 240 Volt 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed.
24
-
-
S&F testing and commissioning of MCB SPN 32 Amp 240 Volt 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed.
1
-
-
S&F sheet metal enclosure DB double door, IP-43 when MCBs to be used SPN, 8 way, 240 V with 200 Amps rated bus bar of suitable size complete all as specified and directed.
3
-
-
M&L for provn of Earthing complete with galvanised steel earth plate electrode, 600x600x6mm buried directly in ground (Earth pit not less than 2.25m deep below the GL) with top edge not less than 1.5 metres below ground level connected with galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel all as shown in electric plate no 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed. Note :- (i) The rate quoted shall also deemed to include the cost of GI wire and protection pipe upto 7.5 Mtr beyond the earth plates electrode and also the cost of the Test point. (ii) Joining of GI earth wire with pipe of the test point shall be done by using suitable cable lugs.
3
-
-
Supply and lay cable XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volt grade cross sectional area 16 sqmm 2 core complete all as specified and directed.
310
-
-
Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr depth for laying of cable as the case may be and getting out in soft and loose type of soil complete all as specified and directed..
55
-
-
M&L for sand cushioning in trenches for the cable etc complete all as specified and directed.
21
-
-
Returning filling, spreading, leveling, watering and well ramming in layers n. exc 25 cm thick complete complete all as specified and directed.
29
-
-
Removing excavated surplus material n. exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr from starting point.
26
-
-
Supplying and laying reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm complete all as specified and directed
1700
-
-
S&F in replacement of GI Pipe light grade 40 mm dia ISI marked on pole on wall or laid in trenches incl all fittings (nut, bolt, clamps & washers)
6
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements