Military Engineer Services Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Military Engineer Services - MES Tender

Works
Civil And Construction
Eprocure
Opening Date4 Oct 2024
Closing Date4 Nov 2024
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
DG Set of capacity 40 KVA.

1

-

-

... More
DG Set of capacity 50 KVA.

1

-

-

... More
DG Set of capacity 63 KVA.

5

-

-

... More
DG Set of capacity 100 KVA.

2

-

-

... More
DG Set of capacity 125 KVA.

1

-

-

... More
DG Set of capacity 200 KVA.

1

-

-

... More
DG Set of capacity 750 KVA.

3

-

-

... More
Dismantling radiator assembly from the engine of following capacity of DG sets by disconnecting inlet and outlet connection overhauling / servicing the radiator, descaling and servicing the radiator internally and externally by using chemicals, including soldering the copper tubes and tank etc for arresting leakage, assembling back including necessary welding and with additional bracket as required, Refixing, reconnecting and testing for proper functioning complete all as specified and directed by Engineer-in-Charge :-

-

-

-

... More
DG Set of capacity 10 KVA.

1

-

-

... More
DG Set of capacity 15 KVA.

2

-

-

... More
DG Set of capacity 40 KVA.

1

-

-

... More
DG Set of capacity 50 KVA.

1

-

-

... More
DG Set of capacity 63 KVA.

4

-

-

... More
DG Set of capacity 100 KVA.

1

-

-

... More
DG Set of capacity 125 KVA.

1

-

-

... More
DG Set of capacity 200 KVA.

1

-

-

... More
DG Set of capacity 750 KVA.

2

-

-

... More
Dismantling of fuel injection pump assembly complete from the engine of following capacity of DG Sets, servicing, over hauling, replacement of valves, washers etc., assembling, calibration, setting for proper function, reassembling and re-fixing all as directed by Engr-in-charge:-

-

-

-

... More
DG Set of capacity 10 KVA.

1

-

-

... More
DG Set of capacity 15 KVA.

1

-

-

... More
DG Set of capacity 40 KVA.

1

-

-

... More
DG Set of capacity 50 KVA.

1

-

-

... More
DG Set of capacity 63 KVA.

4

-

-

... More
DG Set of capacity 100 KVA.

1

-

-

... More
DG Set of capacity 125 KVA.

1

-

-

... More
DG Set of capacity 200 KVA.

1

-

-

... More
DG Set of capacity 750 KVA.

4

-

-

... More
Supply only (in replacement) spin on fuel filter (pre and fine filter) element with O ring for generator set of following capacity complete all as specified and directed :-

-

-

-

... More
DG Set of capacity 10 KVA.

1

-

-

... More
DG Set of capacity 15 KVA.

2

-

-

... More
DG Set of capacity 40 KVA.

1

-

-

... More
DG Set of capacity 50 KVA.

1

-

-

... More
DG Set of capacity 63 KVA.

5

-

-

... More
DG Set of capacity 100 KVA.

2

-

-

... More
DG Set of capacity 125 KVA.

1

-

-

... More
DG Set of capacity 200 KVA.

1

-

-

... More
DG Set of capacity 750 KVA.

2

-

-

... More
Supply only (in replacement) Dry type Air filter element Inner and Outer unit as required at site with O' Ring of suitable for following capacity DG Set complete all as specified and directed :-

-

-

-

... More
DG Set of capacity 10 KVA.

1

-

-

... More
DG Set of capacity 15 KVA.

2

-

-

... More
DG Set of capacity 40 KVA.

1

-

-

... More
DG Set of capacity 50 KVA.

1

-

-

... More
DG Set of capacity 63 KVA.

5

-

-

... More
DG Set of capacity 100 KVA.

2

-

-

... More
DG Set of capacity 125 KVA.

1

-

-

... More
DG Set of capacity 200 KVA.

1

-

-

... More
DG Set of capacity 750 KVA.

4

-

-

... More
Supply only (in replacement) Lub oil filter element with O Ring suitable for following capacity DG Set complete all as specified and directed :-

-

-

-

... More
DG Set of capacity 10 KVA.

1

-

-

... More
DG Set of capacity 15 KVA.

2

-

-

... More
DG Set of capacity 40 KVA.

1

-

-

... More
DG Set of capacity 50 KVA.

1

-

-

... More
DG Set of capacity 63 KVA.

5

-

-

... More
DG Set of capacity 100 KVA.

2

-

-

... More
DG Set of capacity 125 KVA.

1

-

-

... More
DG Set of capacity 200 KVA.

1

-

-

... More
DG Set of capacity 750 KVA.

4

-

-

... More
Supply only (in replacement) By pass filter element with O ring of suitable for following capacity DG Set complete all as specified and directed.

-

-

-

... More
DG Set of capacity 10 KVA.

1

-

-

... More
DG Set of capacity 15 KVA.

2

-

-

... More
DG Set of capacity 40 KVA.

1

-

-

... More
DG Set of capacity 50 KVA.

1

-

-

... More
DG Set of capacity 63 KVA.

5

-

-

... More
DG Set of capacity 100 KVA.

2

-

-

... More
DG Set of capacity 125 KVA.

1

-

-

... More
DG Set of capacity 200 KVA.

1

-

-

... More
DG Set of capacity 750 KVA.

4

-

-

... More
Supply only V-belt suitable for following capacity DG set including removing old unserviceable fan belt all complete all as specified and directed :-

-

-

-

... More
DG Set of capacity 10 KVA.

1

-

-

... More
DG Set of capacity 15 KVA.

1

-

-

... More
DG Set of capacity 40 KVA.

1

-

-

... More
DG Set of capacity 50 KVA.

1

-

-

... More
DG Set of capacity 63 KVA.

5

-

-

... More
DG Set of capacity 100 KVA.

2

-

-

... More
DG Set of capacity 125 KVA.

1

-

-

... More
DG Set of capacity 200 KVA.

1

-

-

... More
DG Set of capacity 750 KVA.

4

-

-

... More
Supply and fixing (in repairs) Water Pump Assy suitable for following capacity DG set including removing old unserviceable water pump assy complete all as specified and directed by Engineer-in-Charge :-

-

-

-

... More
DG Set of capacity 10 KVA.

1

-

-

... More
DG Set of capacity 15 KVA.

1

-

-

... More
DG Set of capacity 40 KVA.

1

-

-

... More
DG Set of capacity 50 KVA.

1

-

-

... More
DG Set of capacity 63 KVA.

4

-

-

... More
DG Set of capacity 100 KVA.

1

-

-

... More
DG Set of capacity 125 KVA.

1

-

-

... More
DG Set of capacity 200 KVA.

1

-

-

... More
DG Set of capacity 750 KVA.

2

-

-

... More
Supply and replacement Water outlet and inlet hose pipe from radiator to Engine and back from Engine to radiator of following capacity of DG set complete all as specified and directed by Engineer-in-Charge.

-

-

-

... More
DG Set of capacity 10 KVA.

1

-

-

... More
DG Set of capacity 15 KVA.

1

-

-

... More
DG Set of capacity 40 KVA.

1

-

-

... More
DG Set of capacity 50 KVA.

1

-

-

... More
DG Set of capacity 63 KVA.

3

-

-

... More
DG Set of capacity 100 KVA.

1

-

-

... More
DG Set of capacity 125 KVA.

1

-

-

... More
DG Set of capacity 200 KVA.

1

-

-

... More
DG Set of capacity 750 KVA.

2

-

-

... More
Supply and replacement Lub oil pipe armoured of suitable length and socket size complete all as specified and directed by Engineer-in-Charge.

-

-

-

... More
DG Set of capacity 10 KVA.

1

-

-

... More
DG Set of capacity 15 KVA.

1

-

-

... More
DG Set of capacity 40 KVA.

1

-

-

... More
DG Set of capacity 50 KVA.

1

-

-

... More
DG Set of capacity 63 KVA.

3

-

-

... More
DG Set of capacity 100 KVA.

2

-

-

... More
DG Set of capacity 125 KVA.

1

-

-

... More
DG Set of capacity 200 KVA.

1

-

-

... More
DG Set of capacity 750 KVA.

4

-

-

... More
Supply and replacement Lub oil pressure guage 0 to 10 kg / sq cmcomplete all as specified and directed by Engineer-in-Charge.

-

-

-

... More
DG Set of capacity 10 KVA.

1

-

-

... More
DG Set of capacity 15 KVA.

1

-

-

... More
DG Set of capacity 40 KVA.

1

-

-

... More
DG Set of capacity 50 KVA.

1

-

-

... More
DG Set of capacity 63 KVA.

1

-

-

... More
DG Set of capacity 100 KVA.

2

-

-

... More
DG Set of capacity 125 KVA.

1

-

-

... More
DG Set of capacity 200 KVA.

1

-

-

... More
DG Set of capacity 750 KVA.

4

-

-

... More
Supply and top up coolant oil 10 to 750 KVA DG set complete all as specified and directed by Engineer-in-Charge.

200

-

-

... More
Supply and replace battery connecting single core copper cable 16sqmm with battery terminal made of brass with nuts/bolts/washer complete all as specified and directed by Engineer-in-Charge.

18

-

-

... More
Supply and fixing SMPS battery charger 12V DC including all fixing accessories and re-wiring with suitable size copper conductor FRLS grade PVC insulated two core cable drawn through PVC conduit not less than 20mm dia as required at site and complete all as specified and directed by Engineer-in-Charge

4

-

-

... More
Disconnecting, dismantling 12V battery charging alternator assembly replacing the unserviceable burnt coil assembly, re-assembling, refixing to engine and testing for satisfactory charging of battery complete all as specified and directed by Engineer-in-Charge :-

-

-

-

... More
DG Set of capacity 10 KVA.

1

-

-

... More
DG Set of capacity 15 KVA.

2

-

-

... More
DG Set of capacity 40 KVA.

1

-

-

... More
DG Set of capacity 50 KVA.

1

-

-

... More
DG Set of capacity 63 KVA.

5

-

-

... More
DG Set of capacity 100 KVA.

2

-

-

... More
DG Set of capacity 125 KVA.

1

-

-

... More
DG Set of capacity 200 KVA.

1

-

-

... More
DG Set of capacity 750 KVA.

4

-

-

... More
Taking out old unserviceable AVR from DG Set and Supply and Fixing AVR (Automatic Voltage Regulator) suitable for DG Set of Make Kirloskar/Cummins/CG of capacity of following capacity having input voltage 2 phase + neutral sensing voltage 415, output voltage 95 V DC, output current 4A DC voltage regulation +/- 1 % average volts, over excitation current tripping, fuse protection 4 A, fast acting and frequency 50 Hz complete all as directed by Engr-in-Charge :-

-

-

-

... More
DG Set of capacity 10 KVA.

1

-

-

... More
DG Set of capacity 15 KVA.

2

-

-

... More
DG Set of capacity 40 KVA.

1

-

-

... More
DG Set of capacity 50 KVA.

1

-

-

... More
DG Set of capacity 63 KVA.

5

-

-

... More
DG Set of capacity 100 KVA.

2

-

-

... More
DG Set of capacity 125 KVA.

1

-

-

... More
DG Set of capacity 200 KVA.

1

-

-

... More
DG Set of capacity 750 KVA.

3

-

-

... More
Supply and fixing in replacement of Digital DG Controller suitable for following capacity of DG Set of any capacity complete and connecting with existing electrical circuit complete all as specified and directed by Engineer-in-Charge.

-

-

-

... More
DG Set of capacity 40 KVA.

1

-

-

... More
DG Set of capacity 50 KVA.

1

-

-

... More
DG Set of capacity 63 KVA.

1

-

-

... More
DG Set of capacity 100 KVA.

1

-

-

... More
DG Set of capacity 125 KVA.

1

-

-

... More
DG Set of capacity 200 KVA.

1

-

-

... More
Supply and fixing (in repairs) Diods set(Rectifier) of Main alternator of DG Set of following capacity complete all as specified and directed by Engineer-in-Charge.

-

-

-

... More
DG Set of capacity 10 KVA.

1

-

-

... More
DG Set of capacity 15 KVA.

2

-

-

... More
DG Set of capacity 40 KVA.

1

-

-

... More
DG Set of capacity 50 KVA.

1

-

-

... More
DG Set of capacity 63 KVA.

5

-

-

... More
DG Set of capacity 100 KVA.

2

-

-

... More
DG Set of capacity 125 KVA.

1

-

-

... More
DG Set of capacity 200 KVA.

1

-

-

... More
DG Set of capacity 750 KVA.

3

-

-

... More
Supply and fixing (in repairs) Contactors 4 pole, 63A, coil volt-240volts, AC 50Hz all as specified and directed

2

-

-

... More
Supply and fixing (in repairs) Contactors 4 pole, 100A, coil volt-240volts, AC 50Hz all as specified and directed

2

-

-

... More
M&L Minor Repair/cleaning of fuel tank, arresting leak using metal paste/sealent or by welding/soldering, replacement of diesel receiver pipe from lock to tank with clamp set all as required at site for following capacity of DG Set complete all as specified and directed by Engineer-in-Charge :-

-

-

-

... More
DG Set of capacity 10 KVA.

1

-

-

... More
DG Set of capacity 15 KVA.

2

-

-

... More
DG Set of capacity 40 KVA.

1

-

-

... More
DG Set of capacity 50 KVA.

1

-

-

... More
DG Set of capacity 63 KVA.

5

-

-

... More
DG Set of capacity 100 KVA.

2

-

-

... More
DG Set of capacity 125 KVA.

1

-

-

... More
DG Set of capacity 200 KVA.

1

-

-

... More
DG Set of capacity 750 KVA.

4

-

-

... More
M&L for minor repair to canopy such as to hinges, locking arrangement etc and painting inside/outside area of DG Set 40 to 125 KVA comprising engine, alternator, genset panel board and fuel tank and canopy, as per standard approved colour code with one coat of synthetic enamel paint cleaning scrubbing of all surface including writing by paint the SM/MES numbers etc all as specified and all directed by Engr-in-charge.

-

-

-

... More
DG Set of capacity upto 50 KVA

6

-

-

... More
DG Set of capacity 100 to 200 KVA

5

-

-

... More
Dismantling, removing the self starter, motor from the engine of following capacity of DG sets, opening the self starter body and overhauling/servicing, replacement of carbon brushes with holders, contact plates, jumping leads and seals, re-varnishing the field coil, armature, re-assembling, testing for smooth functioning and re-fixing with the engine and connecting complete all as specified and directed by Engineer-in-Charge.

-

-

-

... More
DG Set of capacity 10 KVA.

1

-

-

... More
DG Set of capacity 15 KVA.

1

-

-

... More
DG Set of capacity 40 KVA.

1

-

-

... More
DG Set of capacity 50 KVA.

1

-

-

... More
DG Set of capacity 63 KVA.

3

-

-

... More
DG Set of capacity 100 KVA.

1

-

-

... More
DG Set of capacity 125 KVA.

1

-

-

... More
DG Set of capacity 200 KVA.

1

-

-

... More
DG Set of capacity 750 KVA.

3

-

-

... More
Supply and fixing in replacement Battery 12V,150 AH sealed lead acid battery, complete all as specified and as directed.

10

-

-

... More
Supply and fixing (in replacement) Water separator suitable for DG sets of capacity 40 to 125 KVA complete all as specified and directed by Engineer-in-Charge.

-

-

-

... More
DG Set of capacity 10 KVA.

1

-

-

... More
DG Set of capacity 15 KVA.

1

-

-

... More
DG Set of capacity 40 KVA.

1

-

-

... More
DG Set of capacity 50 KVA.

1

-

-

... More
DG Set of capacity 63 KVA.

2

-

-

... More
DG Set of capacity 100 KVA.

1

-

-

... More
DG Set of capacity 125 KVA.

1

-

-

... More
DG Set of capacity 200 KVA.

1

-

-

... More
DG Set of capacity 700 KVA.

3

-

-

... More
Supply and fixing in replacement stop solenoid 12V, 10 amps single coil 75mm dia, for 125 KVA DG set complete all as specified and directed.

-

-

-

... More
DG Set of capacity 10 KVA.

1

-

-

... More
DG Set of capacity 15 KVA.

2

-

-

... More
DG Set of capacity 40 KVA.

1

-

-

... More
DG Set of capacity 50 KVA.

1

-

-

... More
DG Set of capacity 63 KVA.

4

-

-

... More
DG Set of capacity 100 KVA.

1

-

-

... More
DG Set of capacity 125 KVA.

1

-

-

... More
DG Set of capacity 200 KVA.

1

-

-

... More
DG Set of capacity 750 KVA.

3

-

-

... More
Supply and fixing in replacement 4-20mA lube oil pressure sensor suitable for following capacity of DG Set, as per existing make/size, complete all as specified and directed :-

-

-

-

... More
DG Set of capacity up to 63 KVA

3

-

-

... More
DG Set of capacity up to 200 KVA

3

-

-

... More
Supply and fixing in replacement Fuel level sensor suitable for following capacity of DG Set, as per existing make/size, complete all as specified and directed.

-

-

-

... More
DG Set of capacity 10 KVA.

1

-

-

... More
DG Set of capacity 15 KVA.

1

-

-

... More
DG Set of capacity 40 KVA.

1

-

-

... More
DG Set of capacity 50 KVA.

1

-

-

... More
DG Set of capacity 63 KVA.

4

-

-

... More
DG Set of capacity 100 KVA.

1

-

-

... More
DG Set of capacity 125 KVA.

1

-

-

... More
DG Set of capacity 200 KVA.

1

-

-

... More
DG Set of capacity 750 KVA.

3

-

-

... More
Supply and fixing in replacement Thermostat element suitable for following capacity of DG Set, as per existing make/size, complete all as specified and directed.

-

-

-

... More
DG Set of capacity up to 100 KVA

4

-

-

... More
DG Set of capacity 125 KVA

1

-

-

... More
DG Set of capacity 200 KVA

1

-

-

... More
Supply and fixing in replacement of injector nozzle suitable for following capacity of DG Set, as per existing make/size, complete all as specified and directed.

-

-

-

... More
DG Set of capacity 10 KVA.

1

-

-

... More
DG Set of capacity 15 KVA.

1

-

-

... More
DG Set of capacity 40 KVA.

1

-

-

... More
DG Set of capacity 50 KVA.

1

-

-

... More
DG Set of capacity 63 KVA.

4

-

-

... More
DG Set of capacity 100 KVA.

1

-

-

... More
DG Set of capacity 125 KVA.

1

-

-

... More
DG Set of capacity 200 KVA.

1

-

-

... More
DG Set of capacity 750 KVA.

3

-

-

... More
Supply and fixing in replacement of Governing card suitable for following capacity of DG Set, as per existing make/size, complete all as specified and directed.

-

-

-

... More
DG Set of capacity 10 KVA.

1

-

-

... More
DG Set of capacity 15 KVA.

1

-

-

... More
DG Set of capacity 40 KVA.

1

-

-

... More
DG Set of capacity 50 KVA.

1

-

-

... More
DG Set of capacity 63 KVA.

4

-

-

... More
DG Set of capacity 100 KVA.

1

-

-

... More
DG Set of capacity 125 KVA.

1

-

-

... More
DG Set of capacity 200 KVA.

1

-

-

... More
DG Set of capacity 750 KVA.

3

-

-

... More
Supply and fixing in replacement of start/stop Relay card 12/24 DC suitable for following capacity of DG Set, as per existing make/size, complete all as specified and directed.

-

-

-

... More
DG Set of capacity up to 63 KVA

2

-

-

... More
DG Set of capacity up to 200 KVA

2

-

-

... More
Supply and fixing in replacement of generator Actuator 12/24 DC suitable for following capacity of DG Set, as per existing make/size, complete all as specified and directed.

-

-

-

... More
DG Set of capacity up to 63 KVA

4

-

-

... More
DG Set of capacity up to 125 KVA

2

-

-

... More
DG Set of capacity 200 KVA

1

-

-

... More
DG Set of capacity 750 KVA.

3

-

-

... More
Supply and fixing in replacement of generator engine piston suitable for 200 KVA DG Set, as per existing make/size, complete all as specified and directed.

1

-

-

... More
Supply and fixing in replacement of generator engine piston ring set suitable for 125 KVA DG Set, as per existing make/size, complete all as specified and directed.

1

-

-

... More
Supply and fixing in replacement of generator engine intake/exhaust valve suitable for 125 KVA DG Set, as per existing make/size, complete all as specified and directed.

1

-

-

... More
M & L for checking of AMF panels including replacement of unserviceable parts such as Relays, Timers, Power contactors, Auxilary contactors, defective copper wiring, MCCBs etc. for 15 - 200 KVA DG Set, complete all as specified and directed by Engineer-in-Charge. Note: - Spare parts shall be measured and paid separately under Supply only items

2

-

-

... More
Supply only Auxiliary contactor 240 V 3 No & 1 NC

2

-

-

... More
Supply only ON and OFF delay timer 240 V AC

2

-

-

... More
Supply only Earth fault relay.

2

-

-

... More
Supply only Over load relay.

2

-

-

... More
Supply only Under voltage relay.

2

-

-

... More
Supply only DC power contactor for auto starting 12 V

2

-

-

... More
Supply only Power Contactor MCX 11, 4 Pole

2

-

-

... More
Supply only Power Contactor MCX 22, 4 Pole

2

-

-

... More
Supply only Power Contactor MCX 33, 4 Pole

2

-

-

... More
Supply and fix in replacement of Power Contactor MNX 70 , 3P , 415 V including necessary wiring complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
Supply and fix in replacement of Power Contactor MNX 110 , 3P , 415 V including necessary wiring complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
S&F in replacement of On Load Change over switch capacity 315 amps, 415 Volts,4 pole complete with sheet metal enclosure fixed on wall and making proper connections of cables complete all as specified and directed.

10

-

-

... More
Dismantling of 10 KVA Capacity alternator from Generator after Dismantling from Generator shifting to workshop, taking out burnt out winding from Stator & Rotator, Cleaning thoroughly and rewinding the stator with suitable guage of super enameled copper conductor similar to that of existing size including necessary insulating material varnishing, heating, reassembling of alternator, bringing back to the sight refixing and installation and foundation with proper alignment, testing and commissiong complete all as specified and directed by Engineer-in-Charge. Note :- Taking up and down from the site to workshop with vehicle and labour is deemed to be included in quoted rates.

1

-

-

... More
All as per item ser No 51 but capacity 15 KVA.

1

-

-

... More
All as per item ser No 51 but capacity 40 KVA.

1

-

-

... More
All as per item ser No 51 but capacity 50 KVA.

1

-

-

... More
All as per item ser No 51 but capacity 63 KVA.

2

-

-

... More
All as per item ser No 51 but capacity 100 KVA.

2

-

-

... More
All as per item ser No 51 but capacity 125 KVA.

1

-

-

... More
All as per item ser No 51 but capacity 200 KVA.

1

-

-

... More
All as per item ser No 51 but capacity 700 KVA.

3

-

-

... More
Supply and fixing, in replacement, generator Engine harness for 63 KVA capacity of DG Set, as per existing make/size, complete all as specified and directed.

2

-

-

... More
Supply and fixing in replacement generator Engine harness for 125 KVA capacity of DG Set, as per existing make/size, complete all as specified and directed.

2

-

-

... More
Supply and fixing in replacement generator Engine harness for 50 KVA capacity of DG Set, as per existing make/size, complete all as specified and directed.

2

-

-

... More
Supply and fixing in replacement generator Transducer for 50 KVA capacity of DG Set, as per existing make/size, complete all as specified and directed.

2

-

-

... More
Supply and fixing in replacement generator coolent temp sensor for 50 KVA capacity of DG Set, as per existing make/size, complete all as specified and directed.

2

-

-

... More
Renew the Grease in all roller and ball bearings of 63 TO 400 KVA DG Set complete all as specified and directed.

50

-

-

... More
Material and labour for cleaning of Crankcase Breather 63 TO 400 KVA DG Set complete all as specified and directed.

3

-

-

... More
M & L for Electrolyte for battery in sealed Pack complete all as specified and directed.

50

-

-

... More
M & L for Disttilled water for battery in sealed Pack complete all as specified and directed.

50

-

-

... More
M & L for electrical pannel rubber/ insullating rectangular shape mat confirming as per IS 15652 of 6mm thickness, 914 mm X 914 mm X10 mm size.Protection level up to 11KV. High electrical insulation resistance 10,00,000 mcga ohm, 100% shock proof under leakage current 10 mA with Fire Retardant and High dielectric strength of 45Kv for 1 minute &.Washable – Easy to clean etc complete all as specified and directed.

20

-

-

... More
Comprehensive maintenance of electrically operated passenger lifts installed at Lift at Modernised COD, lift in reliable safe and efficient operating condition through MoU with OEM (Make of Lift - ECE Elevator India) by regularly examining, lubricting and adjusting the equipments and carry out planned maintenance (Monthly, Quaterly, Halfyearly and yearly) in systematic and controlled manner suitable for serving Ground+ Second floors i.e. total Three landings with electric power operated doors installed complete all as specified and directed for the following lifts:- Modernised COD :- HQ Building Capacity of 08 Passanger lifts - 01 Nos (Total Qty = 01 Nos X 11 months= 11 per month)

11

-

-

... More
Notes for item No. 70 :- (i) Type of AMC category - Platinum type (ii) The comprehensive maintenance shall be done throuhg OEM i.e. of M/s ECE Elevator India India Pvt Ltd. Necessary intent of MoU from OEM as per Proforma & same shall be uploaded with cover -1, failing which the financial bids of that tenderer will not be opened & reject the tender in technical evaluation. (iii) The contractor will have to submit MOU from M/s ECE Elevator India India Pvt Ltd Pvt Ltd. within fifteen days from date of Acceptance of tender, failing which the contract will be liable to be cancelled and further action to be taken as per policy in vogue. (iv) Contractor will conclude AMC with OEM and copy of the agreement along with invoice will be submitted to Engineer-in-Charge and GE before commencement of AMC. No payment will be made to contractor without submission of valid AMC agreement. (v) The above maintenance include complete maintenance of existing lift by regularly and systematically examining adjusting fabricating as and when required for smooth and efficient functioning of the equipment/lift.

-

-

-

... More
(vi) The contract included for repair, replacement of machines, motors, generators, ropes, inverter/ ARD system, controller parts, PCBs, belts, rollers, gears, bearings, solenoids, coils, chock break shoes, liners, contactors, relays, push bottons, coils, door operator VVF drive, VVVF main drive, car door, safety device limit switches, emergency alarm system with hooter,governor, hoistway door locks,magnetic switches,magnets,door motor,door drive,encoder,car door safety device, Infrared screen, governors, interlock on hoistway doors, gear oil,travelling cable, indicators, LED display boards and minor mechanical spare parts. The cost of above materials are deemed to be included in the rates quoted by the contractor. (vii) Contractor will prominently display his contact/ mobile number and OEM contact number inside and outside the lift on each lift for call in emergency. (viii) All existing earthing of the lifts shall be maintained and made fully functional by the contractor to the entire satisfaction of the Engr-in-Charge. (ix) The OEM will also detail one technician staff to inspect the lift every week regarding functioning of lifts or any other issues arising in the lift. The problem noticed if any to be informed immediately to JE E/M / Engr-in-Charge. OEM Technician should alaways carry service tools during site visit. (x) Contractor or his rep shall come to the site of breakdown within two hours of notification of breakdown. In case the contractor or his rep shall not come to the site of attending breakdown within two hours, a penalty of Rs 600 per fault per day shall be imposed over contractor and shall be deduct from his dues.

-

-

-

... More
Comprehensive periodical maintenance of Capsul lift (ECE Elevator India India Pvt )Ltd.daily Inspections and Maintenance Checks (a) Daily Checks: Visual inspection of lift car interior and exterior. Check emergency lighting and alarm systems.Test door operation and safety mechanisms. (b) Weekly Checks: Inspect door closing and opening speeds.Test emergency stop button functionality.Lubricate moving parts as per manufacturer's guidelines. (c) Monthly Checks:Check and adjust door gib clearance.Inspect electrical components for wear or corrosion.Test backup power systems (if applicable). Quarterly Inspections: Safety Devices: Verify operation of overspeed governors. Check buffer springs and safety gear.Mechanical Components: Inspect ropes, sheaves, and guide rails for wear. Grease bearings and gears. Half yearly Inspections Detailed Examination: Conduct thorough inspection of hydraulic systems (if applicable). Test and calibrate control systems. Inspect and test emergency communication systems. Contractor should takes Certification from authorised OEM to Ensure compliance with local regulations and obtain certification from authorized inspectors. and Maintain a detailed log of inspections and repairs.Document any deviations from normal operation and submits to Engr-in-Charge All as specified and directed by Engr-in-charge

-

-

-

... More
Supply and fixing of 300mm sweep car cabin fan in lift with necessary accessories such as fins/ grills, nuts, bolts and wires, etc.including taking down old unserviceable fan complete all as specified and directed.

1

-

-

... More
M&L for buffing for stainless steel surface inside of lift car cabin complete with using buffing machine and compound for buffing upto remove the dull outlook and rusted spots on steel surface complete all as specified and directed.

1

-

-

... More
Supply and fixing in repairs only sealed maintenance free battries of 18 AH capacity of 12 Volts for suitable in ARD system incl taking down unsv complete all as specified and directed.

2

-

-

... More
Schedule of credit amount of Rs. 73107.00 to be deducted during AOC

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.