Military Engineer Services Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Civil And Construction
Pipe Line Project
Eprocure
Opening Date28 Oct 2024
Closing Soon18 Nov 2024
Tender Amount₹ 45,00,000
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_681625_1Tender No
8726/GE (MIS)/MhowTender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Particular Specification
BOQ Items
Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. illars etc complete all as specified and directed.
500
-
-
M&L for rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement mixing with WPC complete all as specified and directed.
Note: WPC will be measured and paid separately.
400
-
-
Supply only liquid water proofing isi marked (used 200ml per bag of cement) or as per manufacturer instruction complete all as specified and directed.
9.28
-
-
M&L for rendering 10mm thick in CM (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
150
-
-
M&L for rendering 5mm thick on concrete surfaces in cement mortar 1:3 finished on even and smooth without using extra cement as in ceiling, Chajja etc. complete all as specified and directed.
50
-
-
M&L for Preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of white wash complete all as specified and directed.
250
-
-
M & L for preparation of newly plastered surfaces of walls and apply two coats of oil bound distemper over a coat of primer white or tinted complete all as specified and directed.
150
-
-
M & L for preparation of newly plastered surfaces of Ceiling,chajja and applying three coats of white wash complete all as specified and directed.
50
-
-
M&L for preparation of old plastered surfaces of walls and applying two coats of cement base paint complete all as specified and directed.
1500
-
-
M&L for complete removal of existing treatment of old decorated surface of wall and applying two or more coats of 100% Premium arcylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance , dirt resistance exterior paint of required shade over and including 1-2mm thick wall care putty on one coat of priming coat of exterior primer applied complete all as specified and directed.
Makes :- Nerolac -Excel, Asian - Apex, Burger - Weather coat antidust, Dulux - Weather shield. Note- (a) Application of Primer and emulsion to be carried out through air less spray machine (Mechanical means). (b) Wall care putty shall be done properly to receive smooth surface of wall (c) Work will be executed in building upto 30 m height.
5500
-
-
M&L for Preparation of old decorated surfaces of wall by washing rubbing down and stopping of distempered surfaces and applying one coat of oil bound distemper complete all as specified and directed.
3500
-
-
M & L for complete removal of existing treatment on old decorated surface of wall including brooming, washing, rubbing scraping down, Smoke spot, moss, efflorescent salts, trading oil, grasy spots and stopping nails marks and applying three coat of white wash on walls complete all as specified and directed.
500
-
-
All as per serial item No 15.00 above but on ceiling.
500
-
-
M&L for preparation of old painted wooden surface applying one coat of synthetic enamel paint on wooden surfaces of any description, not otherwise, described, over 10cm width or girth complete all as specified and directed.
20
-
-
M&L for preparation of old steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth and apply two coat of synthetic enamel paint over a coat of primer complete all as specified and directed.
50
-
-
M&L for Non Skid coloured Ceramic tiles 7 to 8mm thick(Square/rectangular) area of each tile exc 0.06 sqm but n exc 0.11 sqm in floors over and including 15mm thick screed in CM 1:6 , set & jointed in neat cement slurry and pointed in white cement mixed with pigment to match the colour of tiles incl dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and rubbish off the premises complete all as specified and as directed.
70
-
-
M&L for coloured joint free Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including15mm thick screed in CM(1:6) incl dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and rubbish off the premises complete all as specified and as directed.
70
-
-
M&L for glazed ceramic coloured wall tiles (textured and design as required) in vertical surface as in skirting/dado 450X300X7mm/ 450X350X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in 1:4 CM incl dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and rubbish off the premises complete all as specified and as directed.
80
-
-
M&L for glazed ceramic coloured tiles 300mm x 200mm size 6-7mm thick in dados or skirting over and including rendering 10mm thick in CM (1:4), jointed in neat grey cement slurry and pointed in white or colour cement to match the tiles incl dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and rubbish off the premises complete all as specified and as directed.
100
-
-
M & L for 20 -25 mm thick kota stone, machin cut kota stone slab flooring (mirror polished) over and including 15mm cement screed base laid in CM 1:6 , and jointed in neat cement slurry mixed with pigment to match the shade of slab including rubbing and polishing incl dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc.complete all as specified and as directed.
90
-
-
M&L for Granite (of any type) 18-20mm work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm screed bed in CM 1:6 and dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc.complete all as specified and as directed.
4
-
-
M & L for chequered cement concrete tiles (glossy finish) 40 cm x 40 cm x 25 mm thick set ,jointed and pointed in neat cement slurry in floors with grey cement and no pigment laid over and including 15 mm thick screed bed or bedding layer in CM (1:6) including packing the eadges of tile with PCC 1:3:6 type C1 and dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc.complete all as specified and as directed.
160
-
-
M&L for precast interlocking paver block 60 mm thick (glossy finished) M-35 Grade to IS 15658-2006, with grey cement and no pigment laid over dry sand cushioning, filling of joints with sand including and packing the eadges of tile with PCC 1:3:6 type C1 and demolition of stone slabs and tiles of any description or thickness etc. complete all as specified and directed. (Colour and shape will be approved by GE)
(Note : Sand cushioning shall be measured and paid separately) .
250
-
-
M&L for precast interlocking paver block 80 mm thick (glossy finished) M-40 Grade to IS 15658-2006, with grey cement and no pigment laid over dry sand cushioning, filling of joints with sand including and packing the eadges of tile with PCC 1:3:6 type C1 and demolition of stone slabs and tiles of any description or thickness etc. complete all as specified and directed. (Colour and shape will be approved by GE)
Note : Sand cushioning shall be measured and paid separately.
100
-
-
M&L for stone dust under floors or in foundations including watering and consolidation spreading and levelling in layers n exc. 25 cm thick complete all as specified and as directed.
16.75
-
-
Rounding to edges of stone slabs one edge such as steps cooking platform and other similar situations complete all as specified and as directed.
10
-
-
S & F in repair GI tubing 15mm bore medium grade with all fittings & fixed complete to walls /ceiling or laid in floors complete all as specified and directed.
50
-
-
S & F in repair GI tubing 20 mm Bore medium grade with all fittings & fixed complete to walls /ceiling or laid in floors all complete all as specified and directed.
100
-
-
S & F in repair Galvanised steel tubes 50mm dia medium grade for cattle trap,spout pipe etc including welding, greasing etc all as specified and directed.
20
-
-
M&L for cutting chases, pinning in, making good to facings where required and pointing in CM (1:3) to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth in brick walls complete all as specified and as directed.
15
-
-
S & F in repairs Rotational moulded polyethylene water storage tanks (two layers) of capacity of 500 liters (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, complete all as specified & directed.
10
-
-
S&F in repairs Rotational moulded polyethylene water storage tank (two layer) of capacity 1000 ltr (Cylindrical/vertical with closed top) , ISI marked hoisted & fixed in position and should be sintex antibacterial or equivalent complete all as specified and directed.
5
-
-
S & F 20 mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/2 0 m m - 2 1 0 g m s . /25mm-455gms/ 40mm - 690 gms) complete all as specified & directed.
15
-
-
S & F in repairs 20 mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . /25mm-455gms/ 40mm - 690 gms) complete all as specified & directed.
5
-
-
S & F in repair vitreous china squatting pan “ORISSA PATERN” of size 580 mm X 440 mm, white, with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti syphonage pipe etc and making good complete all as specified & directed.
12
-
-
S & F in repairs Vitreous China wash down water closet pan (pedestal pattern), white colour (excluding fixing bolts, flushing cistern & flush pipe) including trap, Plastic water closet seat, white colour, closed pattern with flat bottom, & cover & mild steel CP or aluminised hinging device complete all as specified and directed.
12
-
-
S & F in repairs wash hand basins, white colour,vitreous china,of size 550x400mm (flat back, or angle back type) including cutting for and pinning in ends of brackets or erecting stand inclusive of waste pipe,waste coupling etc complete all as specified and directed.
2
-
-
S&F in repairs of 32mm dia Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm-45gms/40mm-60 gms) for kitchen sink complete all as specified and directed.
7
-
-
S&F 15mm bore pillar taps, half turn cast copper alloy with capstan heads, chromium plated,fancy type screwed down high pressure with or without lettered “HOT” or “COLD” with long screwed shanks and fly nutscomplete all as specified and directed.
1
-
-
S&F in repair 15mm bore pillar taps, half turn cast copper alloy with capstan heads, chromium plated,fancy type screwed down high pressure with or without lettered “HOT” or “COLD” with long screwed shanks and fly nuts complete all as specified and directed.
2
-
-
S & F in repairs 10 ltrs capacity PVC flushing cistern, low or high level, with inlet, ball valve, syphonic action type, float and handle, PVC Flush pipe , pull or push type including brackets complete all as specified and directed.
26
-
-
S & F in repair CP brass fancy type 15mm bore bib taps half turn, screwed down , and screwed for iron pipe or for brass ferrule complete all as specified and directed.
4
-
-
S & F in repairs PVC connections 15 mm size with PTMT nuts of length 600mm complete all as specified and directed.
4
-
-
S & F in repairs CP fancy type stop valves ,cast copper alloy concealed type , screwed both ends for iron pipe or for union of 15mm bore complete all as specified and directed.
2
-
-
S & F in repairs CP mixer for WHB mixing hot & cold water screwed down for iron pipe 15mm bore complete all as specified and as directed.
4
-
-
S & F in repairs CP Brass Fancy type shower rose 125mm dia with shower arm 30mm long of approved quality complete all as specified and directed.
2
-
-
M&L in repairs PVC (SWR) gully trap 125/110 mm,setting and jointing with solvent cement complete all as specified and directed.
1
-
-
S&F in repairs shelf glass assembly consisting of 5.5mm thick sheet glass,shelf 120mm wide with CP bracket guard and railing 600mm long complete all as specified and directed.
4
-
-
S&F in repairs soap dish (ovel) type mild steel chromium plated of size not less than 50mm dia complete all as specified and directed.
4
-
-
S&F in repair Grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40gms) complete all as specified and directed.
4
-
-
S&F in repairs of brass CP tubular towel rail 20 mm dia 60cm long between flange with brackets etc complete all as specified and directed.
4
-
-
S&F in repair Plastic water closet seat cover, white colour, closed pattern with flat bottom, & cover & mild steel CP or aluminised hinging device complete all as specified and directed.
2
-
-
S&F in repair PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
15
-
-
S&F in repairs MS Framed work Fe-410-W(Gde-E-250) quality-B as in doors or gates of angle or other section with gusset plates, rails braces, etc, complete, drilled for fixing of steel sheeting or other covering. Door, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rail and guides) and hanging also fastening and fixing complete all as specified and directed.
250
-
-
S&F in repairs mild steel work (Tubular, square/rectangular hollow section) as in purline, rafter and wind ties, cleat roof trusses etc including securing bed plate, plat iron fillets for securing wire mesh etc including all necessary drilling bolting or riverting, etc, and similar work conforming to IS 1161-1979 dge St-240 complete all as specified and directed.
450
-
-
Dismantling Asbestos corrugated & Semicorrugated etc sheetin in roof covering of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
110
-
-
S & F Pre-painted galvalum aluminium zinc coating steel based corrugated steel sheet 0.50mm thick (total coated thickness) of any colour having tensile strength of 550 Mpa minimum, yeild strength, it shall be coated with hot dip alloy of 55% aluminimum, 43.5% zinc,1.5% Silicon and finished with resin coat on both surface @ 150 gm/ sqm of coating as specified and shall be fixed with hot dip galvanised, self drilling and self tapping screws neoprened and EDPM washers as in roof covering complete all as specified and directed.
100
-
-
S & F Pre-painted galvalume aluminium zinc coating GI based plain steel, sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. Note :Fixing of GI Sheet can be curved,crimp or any shape as approved by the GE
10
-
-
Cutting channels, grooves or rebates n exc 15cm girth, and trimming surface with or without reinforcement for inserting galvalume sheet on wall and necessary coping work over the sheet along the wall complete all as specified and directed.
15
-
-
M&L for cement concrete type B0 1:2:4 (using 12.5mm graded stone aggregate) as in copings, kneelers, apex stones,bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
2
-
-
M&L for preparation of new steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth and apply two coat of synthetic enamel paint over a coat of primer complete all as specified and directed.
50
-
-
M&L for cement concrete 75mm thick type D-2, (1:4:8) using 40mm graded stone aggregate as in subbase etc. incl demolition of cement concrete (unreinforced) in ground floors and paving n exc. 15cm thickness (below or above ground level) complete all as specified and directed.
505
-
-
M&L for 50mm thick cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protection etc. incl demolition of cement concrete (unreinforced) in ground floors and paving n exc. 15cm thickness (below or above ground level) complete all as specified and directed.
100
-
-
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
10
-
-
S&F in repairs aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) incl powder coating of any colour (Thickness or powder coating not less than 50 micron) complete all as specified and directed.
10
-
-
S&F MS Framed work such as grills,gratings, etc. with ends of barsshouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
60
-
-
S&F 1.25mm thick mild steel, plain, black sheet in hearths; covering to door shutters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/riveted seams including bending, turning up,mitred angles, stopped ends, outlets, etc. complete all as specified and directed.
20
-
-
S&F in repair pre-cast cement concrete (1:2:4) type B-0 using 12.5 mm graded stone aggregate as in louvers and jallies (measured solid) 25 mm thick , including all mouldings and including pre-cast frame set in cement mortar 1:6 complete all as specified and directed.
20
-
-
Excavating in post holes (or similar holes) each in soft/loose soil n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n exc. 25 cm complete all as specified and directed.
8
-
-
M&L for cement Concrete 1:3:6 Type C-2 (using 40mm graded aggregate) as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars & posts (incl caps & bases) complete all as specified and directed.
2
-
-
S&F in repairs Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm long n.exc 10cmm long and diameter of neck 5 to 10mm complete all as specified and directed.
20
-
-
S&F Mild steel Round bar 10 mm dia and over cut to length band to shape required incl cranking, bending spirally for similar work.conforming to Fe-410-W(Gde.E-250) quality-A or Fe 290(Gde-E-165) complete all as specified and directed.
120
-
-
S&F in repair Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed fixed in repair with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed.
20
-
-
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provission of binding wire incl dismantling old fencing
500
-
-
Supply Chain link MS galvanisd fencing, any size or type complete all as specified and directed.
1105
-
-
M&L for sheet glass 3.0 mm thick ordinary quality and glazing with oil putty, in squares n. exc 0.5 Sq.M in each pan incl hacking out old glass complete all as specified and directed.
20
-
-
S&F figured glasspine head type 3.0 mm thick ordinary quality and glazing with oil putty, in squares n. exc 0.5 Sq.M in each pan incl hacking out old glass complete all as specified and directed.
10
-
-
S & F in repair stainless steel wire cloth of 0.36mm dia wire and average width of aperture 1.4mm & fixed with tacks of stainless steel wire staples,etc complete all as specified and as directed.
20
-
-
M&L for preparation of old concrete / PCC tile surface of any description by brooming with coir / wire brushes and cleaning and washing the floor surface with water to remove the fine dust and applying two coats of Lacquer polish (1001) chemical mixed with pigment all as per Manufacturer's instruction complete all as specified and directed by Engineer-in-Charge
100
-
-
M & L for writing bldg No, date of periodical done etc (Block, Roman, Italic or Indian) with white synthetic enamel paint not exc 15 cm height over 30cm dia black synthetic enamel paint base on wall surface all as specified and as directed.
50
-
-
Cutting of shrubs,vegetation including small trees,grass,bush,weed and roots under growth and saplings n.exc 30cm in girth on wall/ roof /chajja upto 14 mtr hight incl necessary scaffolding/ ladder etc and removing to adistance n.exc 50 mtr ,clearing site all as specified and directed.
100
-
-
Attending day to day complaint for Cleaning of blockage floor/nahani/bottle trap of wash hand basin/sink/bathrooms/kitchen and wc (any type) by using hand pump with rubber bucket or by cleaning rod till clear flow of water is observed all complete all as specified and as directed.
Note:- The complaint slips to be collected from the complaint cell daily by the contractor or his authorised representative/ supervisor. The complaint to be attended and cleared within 24 Hrs or otherwise as given in particular specifications from the date and time of handing over of complaint slip and to be deposited to the concerned JE I/C or Engineer-in-Charge duly signed by the users. In case of delay in clearing the complaint, the penalty to be imposed to the contractor as indicated in particular specifications for every day of delay. Necessary precautions as well as safety measures shall be taken and provided by the contractor without any extra cost for working in the foul condition.The contractor shall be entirely responsible for the lapse, mishappenig to any of the manpower deployed at site due to any inadequate safety measures .
1600
-
-
Cleaning of blockage sewer lines of any dia in any position by rodding from both sides between two adjacent manholes or from inspection chamber to manhole or from gully trap to inspection chamber or through inspection eye of any depth till clear flow of sewer/water is observed complete all as specified and as directed at site by Engineer in charge. Note:- Unit rate quoted shall deemed to be included of cleaning of scurbs, grass small roots etc, around the manholes, inspection chamber at adjacent to the pipe lines cleaning etc and along sewage lines wherever required or as directed and no extra payment shall be made on this account).
Note: The length of sewage line to be measured manhole to manhole/chamber for payment purpose. ecessary precautions as well as safety measures shall be taken and provided by the contractor without any extra cost for working in the foul condition.The contractor shall be entirely responsible for the lapse, mishappenig to any of the manpower deployed at site due to any inadequate safety measures .
3000
-
-
M&L for cleaning of septic tank/soak well of any capacity, and any depth in mud in fould poistion by de-sludging, disilting and getting out all silt, sludge, organic and inorganic materials by manuyally / mechanically and removing the sludge to a distance exc 250 mtr but not exc. 500 mtr away from site and burrying in to pits and covered with earth including spreading bleaching powder @ 1 kg per sqm complete all as directed at site, complete all as specified and as directed.
Note:- Necessary precautions as well as safety measures shall be taken and provided by the contractor without any extra cost for working in the foul condition.The contractor shall be entirely responsible for the lapse, mishappenig to any of the manpower deployed at site due to any inadequate safety measures .
2000
-
-
Cleaning of blocked / socked manholes and removal of sludge, soil, & any materials found from manholes by manually or machinically any depth of manhole complete all as specified and as directed.
500
-
-
Cutting in to existing manhole’s for connecting new drains making good to pipe and rendering cutting out existing benching and forming brand channel ( ½ round or ¾ section) in cement concrete type B1 smooth finished and reforming benching as required internal dia pipe 100 mm dia pipes
50
-
-
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes,sewage lines, pier holes, etc and getting out in in any type of soil complete all as specified and directed.
380
-
-
All as per item No 90.00 above but exc 1.50m depth but not exceeding 3.00m depth
50
-
-
Returning filling in, approved earth including spreading, levelling, watering and well ramming in layers n.exc 25cm thick, complete all as sspecified and directed.
120
-
-
Removing excavated surplus soil etc not exc 50 m and depositing where directed at level n.exc 1.5 m above the starting point complete all as specified and directed.
310
-
-
M&L for cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including sub base of manhole complete all as specified and directed.
8
-
-
M&L for 1:3:6 type C-2 using 40 mm graded stone aggregate cement concrete bed to drain pipe including packing under and haunching against side of pipe for 150 mm bore of pipe complete all as specified and directed.
350
-
-
All as per serial item No 95.00 above but for 200 mm bore
150
-
-
S&F in repairs reinforced concrete pipes 150 mm bore, class NP2 , laid and jointed complete with collars, and Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tasted; in cement concrete 1:4:8 type D2 using 40mm graded stone aggregateincluding demolition and breaking up salt glazed ware stoneware pipes, complete all as specified and directed.
100
-
-
All as per serial item No 97.00 above but 200mm bore pipe
100
-
-
Supplying, laying, jointing and testing salt glazed stone ware drain pipe of size 150 mm internal dia of pipe grade 'A' confirming to IS-651-1980 laid in trenches and jointed cement kmortar 1:1 complete including demolition of old pipe complete all as specified and directed.
400
-
-
All as per serial item No 99.00 above but 200mm bore pipe
100
-
-
M&L for brick work with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in CM 1:6 for new manhole/ raising of old manhole/drain complete all as specified and directed.
45
-
-
All as per serial item No 101.00 above but except brick
(Note:- Old Brick obtained from the demolition will be re-used)
11
-
-
M & L for rendering 10mm thick plaster in CM (1:4), of manholes, concrete surfaces, finished even and smooth (without using extra cement) of cement complete all as specified and directed
200
-
-
S&F in repairs 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or fixed to walls including clamps complete all as specified and directed.
10
-
-
S&F in repairs 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or fixed to walls including clamps complete all as specified and directed.
100
-
-
S&F in repair 75mm PVC (SWR) pipe bend complete all as specified and directed.
10
-
-
S&F in repair 110mm PVC (SWR) pipe bend complete all as specified and directed.
20
-
-
S&F in repair 75mm PVC (SWR) junction single (single 'T') equal or unequal complete all as specified and directed.
5
-
-
S&F in repair 110mm PVC (SWR) junction single (single 'T') equal or unequal complete all as specified and directed.
10
-
-
S & F in repair PVC (SWR) nahani trap/floor trap with grating having diameter of outlet 75 mm including joining to waste pipe with solvent cement complete all as specified and directed.
15
-
-
Demolition of reinforced cement concrete n exc 15 cm thickness complete all as specified and directed.
1.4
-
-
M&L for precast reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cover slabs (for manholes etc), shelves and similar articles with plain faces including necessary moulds and setting in cement mortar 1:4 including necessary formwork complete all as specified and directed. (Note:-Reinforcement to be measured separately).
7
-
-
M&L for TMT mild steel bars 10 mm dia and over, cut to length, bent to shape required inluding cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and directed.
700
-
-
S&F in repair low density polyethylene pipes (LDPE) 32 mm dia of pressure rating 6 kgf/sq cm including fitting (bend, tee etc.) fixed complete to walls, ceilings with clamps or in floors etc, complete all as specified and directed.
10
-
-
S&F Sand stone slab in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc. n.exc. 2m in length, punched dressed on faces and along exposed edges, self faced on other side, thickness of sand stone slabs 50 mm thick, complete all as specified and directed.
31
-
-
S & F in repairs Plastic water closet seat cover black or any colour and size closed patter with flat bottom, and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
12
-
-
M & L for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in mass concrete, foundation and any other location etc. complete all as specified and directed.
9
-
-
Extra for forming fair finished drain or channel, 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred, stopped ends complete all as specified and directed.
60
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%