Military Engineer Services Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date21 Nov 2024
Closing Date12 Dec 2024
Tender Amount₹ 37,00,000
Costs
EMD
₹ 74,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_684780_1Tender No
CWE/MHOW/42(T) of 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
B. FEATURES INCLUDED (a)Stops Alarm button in car operating panel with battery back-up
(b)Automatic operation for car fan and light.
(c)Adjustable door open time
(d)Anti-nuisance (empty car)
(e)Anti-nuisance (car call cancellation at direction reversal)
(f)Blower fan in car for ventilation
(g)Braille on push buttons (h)Car call cancellation by double pressing floor button in car operation panel
(i)Door open and door close buttons in car operating panel
(j)Door closing retries
(k) Door nudging
(l) Emergency light (m)Full load by-pass
(n)Home landing
(o)Infra-red screen for car door
(p)Intercom
(q)Jammed landing operating panel call button by-pass
(r) Motor overheat protection, correction drive to next level.
(s)Overload function with audio-visual indication in car operating panel
(t)Phase failure and phase reversal protection
(u)Automatic rescue device in case of power failure
(v)Attendant control
(w)Car arrival chime on car top
(x)Red dot matrix scrolling display in car operating panel
(y)Red dot matrix scrolling display in landing operating panel on All Floors
(z)Fireman control
(aa)Fireman emergency return
(ab)Provision of additional cores in travelling cable for CCTV camera signals/music system wiring
(ac)Voice announcement unit in English language in car
-
-
-
S&F of sub main wiring with four runs of single core PVC insulated and unsheathed multistranded, copper conductor cable of size 6.00 sqmm LT, 1100 volts grade, drawn through and including 25 mm dia PVC non metallic surface conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 6 sqmm single core multistranded copper conductor cable green colour as earth continuity conductor. Note:- (i) Four runs of cable one run of earth wire and one run of PVC non metallic conduit of 25mm dia shall be measured as one run lenght. (ii) Cable required for connection to DBs shall deemed to be included and shall not be measured seperately. (iii) Earth wire shall run inside the PVC conduit.
40
-
-
S&F of sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor cable of size 4.00 sqmm LT, 1100 volts grade, drawn through and including 25 mm dia PVC non metallic surface conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 4 sqmm single core multistranded copper conductor cable green colour as earth continuity conductor. Note:- (i) Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 25mm dia shall be measured as one run lenght. (ii) Cable required for connection to DBs shall deemed to be included and shall not be measured seperately. (iii) Earth wire shall run inside the PVC conduit.
200
-
-
S&F in replacement of sheet metal enclosures Triple pole and neutra 4 way, 440 volt with 200 Amp rated bus bar for vertical DBs (double door) suitable for incoming MCCB and outgoing 4 way MCBs, complete all as specified and directed .
1
-
-
Supply and fixing MCCB 415V 63 Amp 4 pole breaking capacity 20KA complete all as specified and directed.
1
-
-
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of TPN and 40 Amp current carrying capacity in the DB complete with connection testing and commissioning
2
-
-
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of SPN and 6-32 Amp current carrying capacity in the DB complete with connection testing and commissioning
4
-
-
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB/RCB) of SPand 6-32 Amp current carrying capacity in the DB complete with connection testing and commissioning
6
-
-
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts grade, of sizes 3.5 core x 35 Sqmm laying on wall with proper saddle complete all as specified and directed.
200
-
-
Earthing complete for various LT feeder pillar box with galvanised steel earth plate electrode 600 X 600 X 6mm thick directly buried in the ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5 metre below the ground level, connected to galvanised iron strip 32 x 6mm by means of bolts, nuts, chuck nuts and washers of galvanised iron or steel, GI pipe 40mm bore light grade for protection of earthing strip, PCC chamber 1:4:8 type C-1 using 20mm graded stone aggregate. Internal surface of concrete chamber shall be given 12mm thick plaster in cement morter 1:4, funnel with wire gauge of 22 gauge ( 0.63) 8 mesh per linear inch, 50mm thick cover of RCC 1:2:4 type B-1, using 20mm graded stone aggregate reinforced with 8mm TMT bar at 100mm center to center both ways and charcoal dust and common salt all as shown in electrical plate No.3 of MES SSR Part-I and as specified including excavation and earth work and connecting the earthing to an earthing test point as specified and testing on completion all as directed.
Note: Unit rate quoted is inclusive of earth lead and protection pipe upto 7.5m from earth plate.
4
-
-
Earthing complete for various LT feeder pillar box with galvanised steel earth plate electrode 600 X 600 X 6mm thick directly buried in the ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5 metre below the ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, chuck nuts and washers of galvanised iron or steel, GI pipe 40mm bore light grade for protection of earthing strip, PCC chamber 1:4:8 type C-1 using 20mm graded stone aggregate. Internal surface of concrete chamber shall be given 12mm thick plaster in cement morter 1:4, funnel with wire gauge of 22 gauge ( 0.63) 8 mesh per linear inch, 50mm thick cover of RCC 1:2:4 type B-1, using 20mm graded stone aggregate reinforced with 8mm TMT bar at 100mm center to center both ways and charcoal dust and common salt all as shown in electrical plate No.3 of MES SSR Part-I and as specified including excavation and earth work and connecting the earthing to an earthing test point as specified and testing on completion all as directed.
Note: Unit rate quoted is inclusive of earth lead and protection pipe upto 7.5m from earth plate.
2
-
-
M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4.0 mm dia galvanised iron or steel wire
50
-
-
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 32x6mm galvanised iron strip
50
-
-
M & L 20 mm thick machine cut granite (of any type) work (table rubbed and polished) for wall lining( veneering to wall) 12 mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match to match with shade of granite complete as specified and directed.Note-upto any height .
47
-
-
M & L rendering 10 mm thick on brick wall/cement block wall or concrete surfaces in cement mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
60
-
-
M&L fly ash brick work with modular brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
1
-
-
M&L rolled sections ( I section, channels ets as specified) of Fe 410-W (Gde-E-250 quality-A) as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors,drilled to walls etc. Fixed with angle cleats or other connecting plates as specified and directed by engr in charge
200
-
-
M & L PCC 1:3:6 type C-2 using 40 mm graded aggregate as in mass concrete, foundation, PCC bed and any other location etc. complete all as specified and directed.
0.7
-
-
M & L 20 to 25 mm thick machine cut Kota stone slab in flooring or treads of steps over and including 20mm thick screed bed in cement mortar 1:6, laid and jointed with grey cement slurry mixed with pigment to match with shade of slab including rubbing complete all as specified and as directed.
15
-
-
M&L vitrified ceramic tiles mat finished light shade 09 to 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm screed bed in cement mortar 1:6 complete all as specified and directed
20
-
-
S&F Solid PVC Wall Lining consisting of 5mm thick single side prelam PVC sheet used instead of plain colour sheet including PVC sheet fillet of width 35 mm fixing on wall with screw and pvc rawl plug to make PVC frame for fixing of wall paneling with solvent cement etc. complete all as specified and directed.
10.06
-
-
M & L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming
coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
40
-
-
M&L demolition of reinforced cement concrete exc 15 cm thickness but above ground floors complete
0.6
-
-
M&L Rounding to edges of stone slabs one edges, such as in steps, cooking platform, and other similar situations for bullnosing / moulding to exposed edges( any type) and polishing to match the adjoining surfaces complete all as specified & directed.
52
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%